JMEMS_2015

download JMEMS_2015

of 8

description

pub/mems

Transcript of JMEMS_2015

  • 414 JOURNAL OF MICROELECTROMECHANICAL SYSTEMS, VOL. 24, NO. 2, APRIL 2015

    Laser Shock-Induced Conformal Transferring ofFunctional Devices on 3-D Stretchable Substrates

    Huang Gao, Rui Tang, Teng Ma, Hanqing Jiang, Hongyu Yu, and Gary J. Cheng

    Abstract This paper discussed a topdown integrationmethod to achieve the three-dimensional (3-D) microscale con-formal transferring of functional devices on flexible elastomericsubstrates at ambient conditions. By the tunable laser-inducedpressure, the functional device inherits the microscale wrinkle-like patterns, without compromising functions. The functionalmaterials are encapsulated in the biocompatible parylene layersto avoid the drastic plastic deformations in functional layers. Theelectrical resistivity of functional device increases marginally withthe applied laser intensity, aspect ratios of microscale features,and overall tensile strain applied to the whole flexible assembly.The stretchability of the transferred functional devices was stud-ied by measuring the electrical property as function of bendingand tensile strains. It shows that the device can sustain more than40% strain in the stretchable substrate. It is demonstrated thatthe process can achieve the flexible and stretchable functionalintegration conformal to 3-D micrometer-patterns in a fast andscalable way. [2013-0365]

    Index Terms Laser shock, transfer, functional devices,stretchable substrates.

    I. INTRODUCTION

    AS THE building blocks of modern instruments andequipments for sensing, computation, display and com-munication, electronic semiconductor components are revolu-tionized nowadays by two distinct strategies: miniaturizationand stretchability/flexibility. While miniaturization improvesthe computation power in the limited space, systems thatare highly bendable, stretchable, conformable to any surfacetopology, and mechanically robust would greatly expand thehorizon of applications. The diversified applications, such as

    Manuscript received November 27, 2013; revised May 29, 2014;accepted June 14, 2014. Date of publication July 8, 2014; date ofcurrent version March 31, 2015. The work of G. J. Cheng wassupported in part by the National Science Foundation (NSF) CAREERAward CMMI-0547636, and in part by the NSF through the MaterialsProcessing and Manufacturing Program under Grant CMMI-0928752.The work of H. Jiang was supported in part by the NSF under GrantCMMI-0700440. Subject Editor H. Fujita. (Corresponding author:Gary J. Cheng.)

    H. Gao and G. J. Cheng are with the School of Industrial Engineering,Purdue University, West Lafayette, IN 47907 USA (e-mail: [email protected];[email protected]).

    R. Tang is with the School of Electrical, Computer, and EnergyEngineering, Arizona State University, Tempe, AZ 85287 USA (e-mail:[email protected]).

    T. Ma and H. Jiang are with the School for Engineering of Matter,Transport, and Energy, Arizona State University, Tempe, AZ 85287 USA(e-mail: [email protected]; [email protected]).

    H. Yu is with the School of Electrical, Computer, and Energy Engineering,Arizona State University, Tempe, AZ 85287 USA; and is also with the Schoolof Earth and Space Exploration, Arizona State University, Tempe, AZ 85287USA (e-mail: [email protected]).

    Color versions of one or more of the figures in this paper are availableonline at http://ieeexplore.ieee.org.

    Digital Object Identifier 10.1109/JMEMS.2014.2332512

    flexible solar cells [1], flexible displays [2], flexible stresssensors [3], wearable electronics [4], as well as medicalimplants for health monitoring and disease diagnostics [5],have motivated much progress in various fabrication methodsof stretchable conductors and devices.

    Most of the fabrication methods are bottom-up and catego-rized into two major strategies, either stretchable materialsor stretchable structures [6]. In the first strategy, the con-ductive material, such as metals and carbon nano-material,is either dispersed into an elastic matrix to form elasticconductive composites [7] or deposited on the substrate sur-face [8]. The elastic conductor is readily capable of enduringtensile strain more than 100%, but its conductivity changesor even diminishes when defects and delamination occur athigh tensile strains or after fatigue testing. Kim et al., [9]demonstrated stretchable conductors of polyurethane contain-ing spherical nanoparticles deposited by either layer-by-layerassembly or vacuum-assisted flocculation. High conductivityand stretchability were observed in both composites despite theminimal aspect ratio of the nanoparticles. These materials alsodemonstrate the electronic tunability of mechanical properties,which arise from the dynamic self-organization of the nanopar-ticles under stress. Our new strategy can directly transferfunctional devices conformally onto 3D surfaces of flexibleand stretchable substrate, and allow the assembly to inheritstretchability simultaneously. In the second strategy, the brittledevices are bonded onto elastomeric substrates and intercon-nected by stretchable spring-like ribbons of highly conductivemetal or alloy [10]. The ribbons are selectively bonded withelastomeric substrates by surface energy differentiation toform either in-plane serpentines or out-of-plane buckles [11].The ribbons deform to experience most of stretching andbending so that the brittle devices are almost immune toexcessive strains and failure. This strategy requires speciallycustomized microfabrication and metal evaporation technolo-gies, and relatively complicated multiple transfer processes [8].The maximum strain is usually limited to the range of20% to 70% due to adhesive failure and interconnectionredundancy. In addition, this method can only be applied tomaterials that could generate buckling under compression. Itis still an open topic to demonstrate how to assemble morecomplicated multilayer devices on microscale 3D-patternedsurfaces.

    II. PROCESS SCHEMEThe top-down method proposed in this study, laser shock

    induced transferring (LST), provides an alternative to selec-tively fabricate stretchable functional structures conformal to

    1057-7157 2014 IEEE. Personal use is permitted, but republication/redistribution requires IEEE permission.See http://www.ieee.org/publications_standards/publications/rights/index.html for more information.

  • GAO et al.: LASER SHOCK-INDUCED CONFORMAL TRANSFERRING OF FUNCTIONAL DEVICES 415

    Fig. 1. The process scheme of flexible assembly by LST.

    3D microscale surface of the underlying elastomeric substrate.Fig. 1 illustrates the fabrication process schematically. Thelaser-induced shockwave propagates through to-be-deformedlaminated functional materials and provides sufficient momen-tum to achieve the conformal assembly with the underlying-patterned flexible substrates. The shockwave arises whenthe incoming laser pulse irradiates an ablation layer abovefunctional materials and turns it into a plasma plume. The-patterns on the flexible substrates could be either replicatedfrom rigid substrates multiple times by Polydimethylsiloxane(PDMS) replica molding process [12] or induced by pre-straining and oxygen plasma treatments [13]. The patternedmicroscale features are designed to mimic surface wrinkling inpractical surface conditions during biological and biomedicaltransfer, which have been widely applied to tunable adhesionand wetting [14], tunable open-channel microfluidics [15],and stretchable electronics [16]. To minimize the mechanicaldamage to functional materials during deformation, they areencapsulated by symmetrical parylene layers and stay atmechanical neutral plane. The parylene layer not only absorbsmost of shockwave energy, but also provides compliant mediabetween functional layer and sharp microfeatures to mitigatethe localized intensive deformation. A uniform nanolayer ofadhesive (SU-8-2000, MicroChem) will be spin-coated onthe surface of encapsulated functional materials interfacingflexible substrates to improve the bonding strength duringfurther transfers requiring stretching and bending. Anotherstrategy to preserve the assembly functions is to differentiateplastic strains in ductile and brittle functional materials bypatterned 3D surfaces. It is expected that metallic connectionsaligned to wavy regions will experience moderate plasticdeformation, while the devices aligned with flat regions willhave minimal plastic strains.

    LST is a flexible and fast-shaping process suitable for meso-microscale 3D integration. The transferring process is ultrafastdue to the nature of short pulse laser material interaction.

    During each pulse of laser beam (diameter 110 mm),the functional material could be faithfully transferred to3D microscale surface of the underlying substrate withinnanoseconds. In order to integrate large areas, laser beamcould be operated in scanning mode. Given a spe-cific configuration of confining media and ablation mate-rial, the laser pulse intensity, i.e. pulse energy aver-aged over beam size, determines the shockwave pres-sure. The laser intensity could be programmed to changeinstantaneously for different 3D microscale features andfunctional materials. The coded laser intensity also ensureshigh repeatability over multiple tests. The forming area, pend-ing on laser beam size, could be changed in the range of fewmicrometers to millimeters. The laser pulse could readily scanover wafer-scale area or irradiate through mask to generatepatterned shaping. The forming process could be consideredto be athermal owing to the ablation and sacrifice layersabove functional materials, which minimize thermal damageto functional materials. Compared with other stage-transfertechniques, it requires no complementary mold and reducesprocess complexity and cost. As the non-contact driving force,the shockwave has demonstrated its advantages in consistentmesoscale, microscale to nanoscale deformations conformalto the underlying 3D surfaces [17]. The conformal assem-bly of functional materials and the 3D microscale patterns(-patterns) has great potential to realize electronic systemsmore sensitive and responsive to environmental change.

    III. EXPERIMENTAL METHODS

    Fig. 2 illustrates the experimental setup of LST to selec-tively fabricate stretchable functional structures conformal to3D -patterns on the underlying elastomeric substrate. Thelaser pulse is provided by a Q-switched Nd:YAG laser inTEM00 mode and uniformed by a beam diffuser. It transmitsthrough the top glass sample holder and irradiates the ablation

  • 416 JOURNAL OF MICROELECTROMECHANICAL SYSTEMS, VOL. 24, NO. 2, APRIL 2015

    Fig. 2. The experimental setup of conformal flexible assembly by LST.

    Fig. 3. Fabrication process of the shear stress sensor. (a) Thermal growth of SiO2 and deposition of sacrificial Si layer (1 m). (b) Deposition and patterningof Ti/Pt layers (0.12 m /0.02 m) for the sensing element. (c) Deposition of Parylene-C (9 m). (d) Deposition and patterning of a metal layer of Cr/Aufor electrode leads (0.6 m). (e) Deposition and patterning of a thick layer of Parylene-C (12 m) to form the device structure. (f) Etching the underneathSi sacrificial layer leading to the final device.

    layer (graphite coating) into the plasma instantaneously. Con-fined by the sample holder, the plasma generates a transientshockwave which propagates through the aluminum sacrificelayer and the laminated functional materials and shapes theminto structures conformal to the underlying 3D surfaces. Thegraphite ablation was sprayed onto the upper surface ofaluminum sacrifice layer while the bottom surface interfaceswith the laminated thin film, in order to prevent the graphitepollution and direct laser irradiation. The laminated thin filmand 3D surface are bonded simultaneously by spin-coatedadhesive on the interface. The magnitude of shockwave pres-sure is in the range of hundreds of MPa to several GPa,determined by laser intensity, shock impedance of confiningmedia and ablation coating, as well as absorption coefficientof laser energy in plasma generation. In this study, shockwave

    pressure can be controlled by laser intensity solely to preservethe proper function of fabricated devices. The flexible PDMSsubstrates replicate -patterns in Si master molds faithfully bythe method of mixing and curing the Dow Cornings Sylgard184 elastromer kit at 80 for 90 mins before being peeled offfrom Si molds.

    The functional laminates, such as shear stress sensor, wasfabricated by surface micromachining of polymer Parylene-C.Parylene refers to a variety of chemical vapor deposited poly(p-xylene) polymers functioning as moisture and dielectricbarriers. Among them, Parylene-C is most widely used consid-ering its advantages in barrier properties, cost, and processingmethods. In Fig. 3, the fabrication process includes: 1) drythermal grow 0.3 m thick SiO2 on Si wafer, followedby deposition of 1 m sacrificial silicon layer (polysilicon)

  • GAO et al.: LASER SHOCK-INDUCED CONFORMAL TRANSFERRING OF FUNCTIONAL DEVICES 417

    Fig. 4. Schematic of the shear stress sensor. (a) Sensing element; (b) Bond pads. The 3 lines bridging two electrodes are the sensing element, Ti/Pt layerswith thickness of 0.12 m/0.02 m and patterned by lift-off to form a 23 m wide metal traces [18].

    through LPCVD. This layer will be etched completely dur-ing sensor releasing. Then, dry thermal grow approximately0.2 m SiO2; 2) deposit Ti/Pt layers with thickness of0.12 m/0.02 m for the sensing element with e-beam evap-orator, and pattern these layers by lift-off to form a 2 mto 3 m wide metal traces; 3) deposit about 9 m Parylene-C layer in the Parylene vacuum coating system and patternthis layer by oxygen plasma; 4) deposit and pattern a metallayer of Cr/Au for electrode leads (0.02 m/0.6 m); 5)deposit another layer of Parylene-C (12 m) and patternboth Parylene-C layers to form the device structure; 6) etchthe underneath silicon sacrificial layer through XeF2 dryetching system, resulting in the final device. The overall sensordimensions were 4 cm in length, 320 m in width, and 21 min thickness, as illustrated in Fig. 4. We can also start fromSOI wafers and skip the first two steps, but it may furtherincrease the cost due to the higher unit price of SOI wafers.

    IV. RESULTS AND DISCUSSIONFig. 5(a) shows the bending of a conformal assembly of a

    laminated shear stress sensor with a flexible PDMS mold, bythe laser intensity of 0.25 GW/cm2, with the zoom-in viewin Fig. 5(b). In Fig. 5(c) and (d), it shows the images beforeand after LST of a laminated shear stress sensor on a flexible-patterned PDMS mold. In Fig. 5(d), the -patterns on thesurface of PDMS mold, replicated from a master Si micro-mold, were faithfully transferred to the ductile connection ofthe sensor. The -pattern is 5 mm square in area, 160 min pitch width and 50 m in depth. The sensor resistivitychanged from 1.215K to 1.292K after LST and Temper-ature Coefficient of Resistance (TCR) was kept unchanged

    at approximately 0.11%/C. The electrical resistance R ofthe metallic connection is determined by its length l, itscross-sectional area S, and the intrinsic resistivity of thematerial: R = lS . The slight increase of sensor resistivityresults from the longitudinal extension and the cross-sectiondecrease of ductile metallic connections arising from thelocalized plastic deformation conformal to the -patterns.The deformation-induced microstructural defects, such asdislocations, will also contribute to the resistivity increase. Theapplied laser intensities and the aspect ratios of -patternsneed to be controlled to avoid the fracture and failure ofmetallic connection. This method assumes that the parylenelayer absorbs most of shockwave energy while providing acompliant soft substrate to the encapsulated functional layer.To validate this assumption, the laminated sensor was replacedby a 5 m thick laminated thin film. Its cross section wasfabricated by Focused Ion Beam (FIB) and characterized inScanning Electron Microscope (SEM) in Fig. 5(e), showing itssymmetric structures deposited on Si wafer. The thin film wasdeformed on another PDMS mold with wavy surface featuresand peeled off from PDMS substrate and characterized indi-vidually upside down in FIB in Fig. 5(f), since non-conductivePDMS substrate would deteriorate local ion beam cuttingand observation if otherwise. Its cross section shows that,after laser-induced shock and deformation, the sandwichedAu layer keeps its thickness almost constant along the wavewhile parylene is subject to violent thickness changes, esp. inthe layer interfacing PDMS mold. At the wave valley withsharp curvature, parylene thickness increases from 2.4 m to7.86 m. The experimental observation reveals two underlyingmechanisms coexisting to achieve uniform and significant

  • 418 JOURNAL OF MICROELECTROMECHANICAL SYSTEMS, VOL. 24, NO. 2, APRIL 2015

    Fig. 5. (a) Bending of conformal assembly of a laminated shear stress sensor with a flexible PDMS mold, by the laser intensity of 0.25 GW/cm2. (b) Thezoom-in view of (a) demonstrates the structure after the sensor is transferred to the microscale pattern on the surface of PDMS mold. (c) The optical imagesshows the integration of sensor and PDMS micromold before LST (d) after transferring of a laminated shear stress sensor to a flexible -patterned PDMS mold.The laser intensity applied to make this assembly is 0.25 GW/cm2. The SEM images of conformal assembly of laminated thin film with a wavy PDMS moldand the cross sectional view of the parylene layer and metallic connection layer (e) before and (f) after LST. After LST, the laminated thin film was peeledoff from PDMS mold, then separately cut and characterized its convex Lower Side upside down in FIB/SEM. The applied laser intensity is 0.30 GW/cm2.

    plastic strain in functional layer. First, the encapsulation layernot only allows functional material to sustain large plasticstrain, but also provides compliant media between functionallayer and sharp microfeatures to mitigate the localized inten-sive deformation. More importantly, the permanent plasticdeformation of parylene layer absorbs most of laser-inducedshockwave energy. Second, the through-thickness compressive

    shockwave suppresses the debonding between parylene andAu layer so as to reduce the localized necking. It has beenproved experimentally and analytically that the well-bondedmetallic interconnections could sustain strains up to a fewtens of percent without appreciable cracks since the local-ized necking could be suppressed by the adherent flexiblesubstrate [19].

  • GAO et al.: LASER SHOCK-INDUCED CONFORMAL TRANSFERRING OF FUNCTIONAL DEVICES 419

    Fig. 6. The resistivity changes of shear stress sensors in the flexible assemblies: (a) due to the increasing laser intensities and aspect ratios of -patterns;(b) due to uniaxial stretching; (c) due to pure bending. The samples in (b) were fabricated by laser intensity: 0.25 GW/cm2 in Group (a), and those in (c) bylaser intensity: 0.13 GW/cm2 in Group (a). In (d), d is the thickness of flexible assembly, which is approximately equal to the thickness of PDMS substratesince that of shear stress sensor is only 20 m. r is the radius of cylindrical surface.

    TABLE ITHE DIMENSIONS OF MICRO-PATTERNS REPLICATED INTO

    PDMS SUBSTRATE

    The applied laser intensities and the dimensions or aspectratios of -patterns need to be controlled to avoid inducingexcessive plastic strains or fractures to functional materials.

    In order to characterize their effects on the device functions,a batch of shear stress sensors were selected with the sameinitial electrical resistivity and deformed onto two different-patterns by the increasing laser intensities. The -patternson the PDMS substrates have been displayed in Fig. 5(c)and the dimensions of -patterns summarized in Table I.The opening width of micro-trench in Pattern A is 100 m,identical with that in Pattern B, while its depth in Pattern Ais only 30 m, less than that in Pattern B (50 m). Giventhe same applied laser intensities, the metallic connectionwill be subjected to more longitudinal elongation, i.e. moreplastic strains, in Pattern B with higher aspect ratio -patterns,which results in a slightly higher increase of sensor resistivity(See Fig. 6(a)). It is also observed in Fig. 6(a) that theresistivity increases with the applied laser intensities. It couldbe attributed to the increased microstructural defects arisingfrom the higher laser-induced shockwave pressure. There isonly a very slight resistivity change in the range of high laserintensities when the sensors have already approached localized

  • 420 JOURNAL OF MICROELECTROMECHANICAL SYSTEMS, VOL. 24, NO. 2, APRIL 2015

    conformal deformations. When the applied laser intensity issufficient to achieve the deformations conformal to microscalefeatures, the excessive shockwave energy could result in morethrough-thickness compression of laminated structures.

    The effect of overall tensile strains on flexible assem-blies is demonstrated in Fig. 6(b), when they are subject touniaxial stretching. In this study, the assemblies of shearstress sensor and PDMS substrate are chosen from the sam-ples in Fig. 5(c) and (d), processed under laser intensityof 0.25 GW/cm2. The PDMS substrates are stretched toexperience the overall tensile strains of 5%, 10%, 15% and20%, leading to the linear increase of resistivity approximately.The electrical resistivity changes induced by tensile stretchingare found to be one order less than those introduced duringassembly process. It is believed that during this macroscalestretching, the PDMS substrate undergoes uniform tensilestrains while the localized tensile strain in the -patternsis reduced by the wrinkle-like microfeatures, which deformelastically to mitigate stretching in functional devices.

    The effect of bending on functional assemblies is shownin Fig. 6(c). The assemblies, processed under laser intensityof 0.13 GW/cm2 in Fig. 5(c), were wrapped onto the cylin-drical surfaces with increasing curvatures, resulting in theincreasing bending angles on the cylindrical surface. Whenthe thickness of functional assemblies, d, is much less thanthe bending radius, r, the bending-induced tensile strain inlaminated sensors could be approximated by d/2R. In thisstudy, the thickness of flexible assembly is about 1 mm whilethe bending radii are in the range of 1545 mm, resultingin the average tensile strains in the laminated sensors lessthan 7%. It shows that the resistivity of the functional assem-blies increases consistently with curvatures and induced tensilestrains. Further bending of functional assembly often results inthe delamination of laminated sensors from flexible substrates.

    V. CONCLUSION

    In this study, we have demonstrated the process capabilityof LST to achieve the flexible and stretchable functionalassemblies conformal to 3D -patterns in a fast-shaping andscalable way. The symmetrical elastomeric encapsulation offunctional materials helps to extend the material formabilityand absorb most of laser-induced shockwave, preserving thedevice functions during conformal deformations. The effectsof the applied laser intensities, -pattern designs, pure bendingand uniaxial stretching over the flexible assemblies on the elec-trical resistivity of functional assemblies have been character-ized. It shows that the device can sustain more than 40% strainin the stretchable substrate. The increase of resistivity arisesfrom the longitudinal elongation and cross-section decreasealong the conformal -patterned deformations, as well as theaccumulated microstructural defects in the metallic conduc-tive connections. The overall assembly process completes innanoseconds at ambient temperature and pressure. Coupledwith the inherent flexibility and scalability of laser processing,LST has the great potentials in the diversified applicationsneeding flexible and stretchable electronics.

    REFERENCES[1] A. Chiril et al., Highly efficient Cu(In,Ga)Se2 solar cells grown on

    flexible polymer films, Nature Mater., vol. 10, no. 11, pp. 857861,2011.

    [2] T. Geller, The promise of flexible displays, Commun. ACM, vol. 54,no. 6, pp. 1618, 2011.

    [3] K. Noda, H. Onoe, E. Iwase, K. Matsumoto, and I. Shimoyama,Flexible tactile sensor for shear stress measurement using transferredsub-m-thick Si piezoresistive cantilevers, J. Micromech. Microeng.,vol. 22, no. 11, p. 115025, 2012.

    [4] K. Cherenack, C. Zysset, T. Kinkeldei, N. Mnzenrieder, and G. Trster,Woven electronic fibers with sensing and display functions for smarttextiles, Adv. Mater., vol. 22, no. 45, pp. 51785182, Dec. 2010.

    [5] H. Yu, L. Ai, M. Rouhanizadeh, D. Patel, E. S. Kim, and T. K. Hsiai,Flexible polymer sensors for in vivo intravascular shear stress analysis,J. Microelectromech. Syst., vol. 17, no. 5, pp. 11781186, Oct. 2008.

    [6] J. A. Rogers, T. Someya, and Y. Huang, Materials and mechanics forstretchable electronics, Science, vol. 327, no. 5973, pp. 16031607,2010.

    [7] T. Sekitani, Y. Noguchi, K. Hata, T. Fukushima, T. Aida, and T. Someya,A rubberlike stretchable active matrix using elastic conductors,Science, vol. 321, no. 5895, pp. 14681472, 2008.

    [8] X. Wang, H. Hu, Y. Shen, X. Zhou, and Z. Zheng, Stretchableconductors with ultrahigh tensile strain and stable metallic conductanceenabled by prestrained polyelectrolyte nanoplatforms, Adv. Mater.,vol. 23, no. 27, pp. 30903094, Jul. 2011.

    [9] Y. Kim et al., Stretchable nanoparticle conductors with self-organizedconductive pathways, Nature, vol. 500, no. 7460, pp. 5963, 2013.

    [10] X. Hu, P. Krull, B. de Graff, K. Dowling, J. A. Rogers, and W. J. Arora,Stretchable inorganic-semiconductor electronic systems, Adv. Mater.,vol. 23, no. 26, pp. 29332936, 2011.

    [11] D.-H. Kim, J. Xiao, J. Song, Y. Huang, and J. A. Rogers,Stretchable, curvilinear electronics based on inorganic materials, Adv.Mater., vol. 22, no. 19, pp. 21082124, 2010.

    [12] T.-K. Shih, C.-F. Chen, J.-R. Ho, and F.-T. Chuang, Fabrication ofPDMS (polydimethylsiloxane) microlens and diffuser using replicamolding, Microelectron. Eng., vol. 83, nos. 1112, pp. 24992503,2006.

    [13] C. de Menezes Atayde and I. Doi, Highly stable hydrophilic surfacesof PDMS thin layer obtained by UV radiation and oxygen plasmatreatments, Phys. Status Solidi C, vol. 7, no. 2, pp. 189192, 2010.

    [14] H. E. Jeong, M. K. Kwak, and K. Y. Suh, Stretchable,adhesion-tunable dry adhesive by surface wrinkling, Langmuir, vol. 26,no. 4, pp. 22232226, 2010.

    [15] K. Khare, J. Zhou, and S. Yang, Tunable open-channel microfluidics onsoft poly(dimethylsiloxane) (PDMS) substrates with sinusoidal grooves,Langmuir, vol. 25, no. 21, pp. 1279412799, 2009.

    [16] D.-Y. Khang, H. Jiang, Y. Huang, and J. A. Rogers, A stretchableform of single-crystal silicon for high-performance electronics on rubbersubstrates, Science, vol. 311, no. 5758, pp. 208212, 2006.

    [17] H. Gao, R. Tang, T. Ma, H. Jiang, H. Yu, and G. J. Cheng, Directintegration of functional structures on 3-D microscale surfaces bylaser dynamic forming, J. Microelectromech. Syst., vol. 22, no. 6,pp. 14281437, Dec. 2013.

    [18] R. Tang, H. Huang, Y. M. Yang, J. Oiler, M. Liang, and H. Yu,Three-dimensional flexible thermal sensor for intravascular flowmonitoring, IEEE Sensors J., vol. 13, no. 10, pp. 39913998, Oct. 2013.

    [19] J. Wu et al., Stretchability of encapsulated electronics, Appl. Phys.Lett., vol. 99, no. 6, p. 061911, 2011.

    Huang Gao received the Ph.D. degree in industrialengineering from Purdue University, West Lafayette,IN, USA, in 2012, and the B.S. and M.S. degreesin mechanical engineering from Shanghai Jiao TongUniversity, Shanghai, China, in 2001 and 2004,respectively. His research focuses on micronanoscalefabrication, laser processing, and dynamic defor-mations. He was with GE Consumer & Industrial,Louisville, KY, USA, until 2007. He is currentlya Senior System Development Engineer with OtisElevator, Farmington, CT, USA.

  • GAO et al.: LASER SHOCK-INDUCED CONFORMAL TRANSFERRING OF FUNCTIONAL DEVICES 421

    Rui Tang received the B.S. degree from theHuazhong University of Science and Technology,Wuhan, China, in 2009, and the M.S. degree fromArizona State University, Tempe, AZ, USA, in 2011,where he is currently pursuing the Ph.D. degreewith the School of Electrical, Computer, and EnergyEngineering. His current research includes the devel-opment of MEMS flow sensors, 3-D MEMS pack-aging, and flexible, stretchable, and foldable skinswith integrated sensors and electronics.

    Teng Ma received the B.S. degree in thermal andpower engineering from Xian Jiaotong Univer-sity, Xian, China, in 2004, and the M.S. degreein mechatronics engineering from the Universityof Electronic Science and Technology of China,Chengdu, China, in 2009. He is currently pursuingthe Ph.D. degree in mechanical engineering withthe School for Engineering of Matter, Transport,and Energy, Arizona State University, Tempe, AZ,USA, where he is with Dr. Hanqing Jiangs ResearchGroup. His research focuses on buckled stiff thin

    film on soft substrate for versatile functional materials, including anodes forlithium-ion batteries, optical gratings for microstrain sensors, and piezoelectricmaterials for energy harvesting devices.

    Hanqing Jiang is an Associate Professor inMechanical and Aerospace Engineering with Ari-zona State University, Tempe, AZ, USA. He receivedthe Ph.D. degree in solid mechanics from TsinghuaUniversity, Beijing, China, in 2001, and was a Post-Doctoral Research Associate with the Universityof Illinois at UrbanaChampaign, Champaign, IL,USA, before joining Arizona State University in2006. His current research interest is the multi-physics modeling and experiments for heterogeneoushard and soft materials.

    Hongyu Yu received the B.S. and M.S. degreesfrom Tsinghua University, Beijing, China, in 1997and 2000, respectively, and the Ph.D. degree fromthe University of Southern California, Los Angeles,CA, USA, in 2005. He holds the joint positionbetween the School of Earth and Space Explorationand the School of Electrical, Computer, and EnergyEngineering at Arizona State University, Tempe, AZ,USA. His research focuses on microelectromechan-ical systems for Earth and Space applications withan interest on microseismometer, harsh environment

    sensing, wireless sensing systems, flexible and stretchable electronics, andmanufacture.

    Gary J. Cheng received the Ph.D. degree inmechanical engineering from Columbia University,New York, NY, USA, in 2002. He is an AssociateProfessor with the School of Industrial Engineeringand Mechanical Engineering by courtesy. He isa Fellow of the American Society of MechanicalEngineers. His research interests are scalable man-ufacturing of 0-D3-D micro/nanostructures, lasermatter interaction, and mechanical/physical propertyenhancement of materials.

    /ColorImageDict > /JPEG2000ColorACSImageDict > /JPEG2000ColorImageDict > /AntiAliasGrayImages false /CropGrayImages true /GrayImageMinResolution 150 /GrayImageMinResolutionPolicy /OK /DownsampleGrayImages true /GrayImageDownsampleType /Bicubic /GrayImageResolution 600 /GrayImageDepth -1 /GrayImageMinDownsampleDepth 2 /GrayImageDownsampleThreshold 1.50000 /EncodeGrayImages true /GrayImageFilter /DCTEncode /AutoFilterGrayImages false /GrayImageAutoFilterStrategy /JPEG /GrayACSImageDict > /GrayImageDict > /JPEG2000GrayACSImageDict > /JPEG2000GrayImageDict > /AntiAliasMonoImages false /CropMonoImages true /MonoImageMinResolution 400 /MonoImageMinResolutionPolicy /OK /DownsampleMonoImages true /MonoImageDownsampleType /Bicubic /MonoImageResolution 1200 /MonoImageDepth -1 /MonoImageDownsampleThreshold 1.50000 /EncodeMonoImages true /MonoImageFilter /CCITTFaxEncode /MonoImageDict > /AllowPSXObjects false /CheckCompliance [ /None ] /PDFX1aCheck false /PDFX3Check false /PDFXCompliantPDFOnly false /PDFXNoTrimBoxError true /PDFXTrimBoxToMediaBoxOffset [ 0.00000 0.00000 0.00000 0.00000 ] /PDFXSetBleedBoxToMediaBox true /PDFXBleedBoxToTrimBoxOffset [ 0.00000 0.00000 0.00000 0.00000 ] /PDFXOutputIntentProfile (None) /PDFXOutputConditionIdentifier () /PDFXOutputCondition () /PDFXRegistryName () /PDFXTrapped /False

    /Description >>> setdistillerparams> setpagedevice