JLab Polarized Source

40
JLab Polarized Source Happex Collaboration Meeting May 18, 2007 P. Adderley, J. Brittian, J. Clark, J. Grames, J. Hansknecht, M. Poelker, M. Stutzman, R. Suleiman, K. Surles-Law

description

JLab Polarized Source. Happex Collaboration Meeting May 18, 2007 P. Adderley, J. Brittian, J. Clark, J. Grames, J. Hansknecht, M. Poelker, M. Stutzman, R. Suleiman, K. Surles-Law. Outline. G0 Experience: Laser-Table Setup, Halls Cross-talk, … Helicity Magnets Commissioning - PowerPoint PPT Presentation

Transcript of JLab Polarized Source

Page 1: JLab Polarized Source

JLab Polarized Source

Happex Collaboration Meeting May 18, 2007

P. Adderley, J. Brittian, J. Clark, J. Grames, J. Hansknecht, M. Poelker,

M. Stutzman, R. Suleiman, K. Surles-Law

Page 2: JLab Polarized Source

G0 Experience: Laser-Table Setup, Halls Cross-talk, …

Helicity Magnets Commissioning

Q-weak 250 Hz Helicity Flip Test and the New HV Switch

FFB Diagnostic and Measuring Parity-Quality of Beam

Paper: “Conducting Parity Violation Experiments at CEBAF”

Mott Polarimetry, Load-Lock Gun, and more …

Outline

Page 3: JLab Polarized Source

G0 Experience: Laser-Table Setup and Halls Crosstalk

Page 4: JLab Polarized Source

• Pockels Cell (PC) HVs, roll, pitch, and yaw should be optimized using the spinning HWP and a scope.

• No need to do laser work with the QPD in the tunnel.

• PC x & y should be optimized to minimize the steering with the electron beam; since Jan 07, automated PC X & Y stages were installed.

• Use PITA and RHWP to zero the charge asymmetry and position differences (with the electron beam).

Summary of G0 Experience

Page 5: JLab Polarized Source

IN / PITA=0

Choose: x=0, y=90 mils

On the Laser Table

Page 6: JLab Polarized Source

OUT / PITA=0

Choose: x=70, y=90 mils

On the Laser Table

Page 7: JLab Polarized Source

OUT / PITA=0

Choose: x=67, y=91 mils

With the electron beam

Page 8: JLab Polarized Source

Laser Table Setup and Pockels Cell Alignment (G0 Experience):

• Laser Table:

1. Check laser spot is round (1mm diameter) and has no tails or satellites and centered on the Pockels Cell.

2. With the spinning HWP in front of LP, minimize the residual linear polarization. Find the optimal +HV, -HV, roll, pitch, and yaw of the PC. Check for both IHWP= IN & OUT.

• Electron Beam:1. Establish electron beam in the injector. Find the BPMs pedestals by doing a current scan

with the iocse’s set in “Gains off” mode.

2. Turn OFF the PC and take a long run to check for electronic noise. Turn it back ON.

3. You will use IPM1I02 to finish the setup but it’s good to check IPM1I04 and IPM1I06.

4. Do an x & y translational scans for both IN and OUT. Find PC x & y that minimize the PC steering.

5. For IN, do a RHWP at PITA=0 and another one at PITA=-180 V. Find the RHWP angle that further minimizes the position differences and charge asymmetry, you will have to change the PC high voltage to new values. Repeat this for OUT.

6. Now for both IN and OUT you have determined: PC x, PC y, +HV, -HV, RHWP angle. The IA voltage should be 5 V for both IN and OUT. Over time, IN and OUT will drift to their own IA values.

Page 9: JLab Polarized Source

361 MeV, 35 uA January LD2

Page 10: JLab Polarized Source

Halls A & C Cross-talk

• Hall A IA Scan (80 uA)• Hall C Charge

asymmetry and position differences during the Hall A IA Scan (20 uA)

1. Hall A IA Scan:

Page 11: JLab Polarized Source

2. Hall C Charge Asymmetry Width:

Hall C @ 20 uA

Hall A @ 90 uA

Hall C @ 20 uA

Hall A OFF

Page 12: JLab Polarized Source

Helicity Magnets Commissioning

Page 13: JLab Polarized Source

MHE0L01V

MHE0L03V,MHE0L03H

MHE0L02H

110 VACIsolation

TransformerGrounded cage containing

electrically isolated helicity magnet controls

(VME)

Tube protecting Litz magnet wire

Injector Helicity MagnetInstallation (0L01-0L03)

January 5-6, 2004

Page 14: JLab Polarized Source

Calibration

• Each magnet can kick both helicity states

• Very small coupling to charge asymmetry (100 times smaller than PZT)

• The position feedback is not coupled to the charge feedback

• Can do position feedback on both position and angle in x & y

Page 15: JLab Polarized Source

Position Feedback Test I• Introduce large position differences:

Magnet 1 at even DAC = 500

Page 16: JLab Polarized Source

• Turn ON position feedback: Zero position differences at 0L05 and 0L06

Page 17: JLab Polarized Source

Position Feedback Test II• Introduce large position differences: Move the Pockels Cell from its optimal position on the laser table

Page 18: JLab Polarized Source

• Turn ON position feedback: Zero position differences at 0L05 and 0L06

Page 19: JLab Polarized Source

Position Feedback Test III:• 1-day G0 Production:

Page 20: JLab Polarized Source

Electrical Pick-up• One big concern: Will other elements on

the beam-line see the helicity signal? Check this with Pockels Cell OFF and Helicity Magnets

OFF.

Page 21: JLab Polarized Source

• Turn ON magnet 1: Power it to 1000 times its operational value. Look for

position differences upstream the magnet

Page 22: JLab Polarized Source

Summary:

Helicity Magnets can be used to do

position feedback

Some improvements are still needed …1. Increase the DAC resolution by at least a factor of 10.

2. Better selection of BPMs to do feedback on.

Page 23: JLab Polarized Source

Commissioning of the 250 Hz Helicity Flip and the New HV Switch

Page 24: JLab Polarized Source

Changes needed to run at 250 Hz • New Pockels Cell HV Switch to replace the old switch

• The Helicity Board is programmed for either 30 Hz or 250 Hz with Time-Settle of 60 us, 100 us, 200 us, or 500 us

• Check that tools we need still can work at 250 Hz and 60 us T-Settle:– Parity DAQs – Mott and Moller Polarimeters– Helicity Magnets– …

Worked Fine

Page 25: JLab Polarized Source

30 Hz Flip

PC OFF, new Switch

Issue I: New Switch Electrical Pickup

30 Hz Flip

PC OFF, old Switch

Page 26: JLab Polarized Source

Can 60 Hz noise be used to

study the beam

envelope?

Issue II: 60 Hz Position Noise

Page 27: JLab Polarized Source
Page 28: JLab Polarized Source
Page 29: JLab Polarized Source

After moving an ion-pump power supply away from the beam-line

More 60 Hz noise

search to be

continued …

Page 30: JLab Polarized Source

FBB Diagnostic and Measuring Parity-Quality of Beam

Richard Dickson

Page 31: JLab Polarized Source

The Accelerator BPM Measurement • Developed by Richard Dickson.

• It uses the FFB diagnostic system to read the BPMs wires. Currently running on iocse9 in Hall A and iocse14 in Hall C. These two IOCs receive only the delayed helicity signal.

• Each wire is sampled at 1800 Hz: for Hall A (Linac style SEE BPM) each sample is 64 us long and consists of 8 sub-samples each 8 us. For Hall C (Transport style BPM) a single sample is taken at the 1800 Hz rate. Two seconds of data are acquired for each helicity state (~3600 samples). For each five second readout, one second is reserved for computation and output by EPICS.

• For each sample:– The 4-wires (pedestal subtracted) are added for all the BPMs in each feedback

system (eight), and x & y positions are calculated individually for each BPM

• Data Processing:– Data is summed for any given helicity window and the sum stored for later correlation with the

delayed helicity signal. There is a dead time at both beginning and end of the helicity window. Beam trips are filtered away.

– This results in roughly 60 samples being summed together in any helicity window. – The helicity correlated sum for a window are then further summed into a running total for that

state until approx two seconds of data are acquired per state.– After completion of data acquisition, asymmetries and differences are computed. These are

then available via EPICS as well as values that are further digitally filtered.

Page 32: JLab Polarized Source

Measuring Position Differences Helicity Magnet 1 ON

+/- 150 DACs

Page 33: JLab Polarized Source

• Charge asymmetry and position differences agree to better than 10%.

• Modify the BPM software to calculate also error bars or RMSs.

• Hardware and software changes to the Injector IOCs to be able to measure helicity correlated properties in the Injector (iocse11, iocse12, iocse19 – 23 BPMs) – July – Sept. 07

Results

FFB Diagnostic Hall A

Dx_1C08 (um) -8 +7

Dy_1C08 (um) -19 +18

Dx_1C12 (um) 18 -14

Dy_1C12 (um) -43 +40

Page 34: JLab Polarized Source

Paper: “Conducting Parity Violation Experiments at CEBAF”

Page 35: JLab Polarized Source

Paper Idea: Conducting Parity Violation Experiments at CEBAF.Target Journal: Phys Rev A or Nuclear Instr and Methods A or Rev of Scientific Instr. First draft due by July 1st, 2007. Format: plain text or doc or latex – I will put things together in Latex.Figures: “eps” format.

Collaboration (in no particular order, who did I forget?): JLab: Suleiman (POC), Hansknecht, Poelker, Grames, Chao, Kazimi, Bogacz, Dickson …HAPPEx: Paschke (POC), Cates, Kumar, Souder, Michaels, Kaufman, Snyder …G0: Pitt (POC), Armstrong, Nakahara, Bailey …Topics (in no particular order, what did I forget?)

Introduction: (Armstrong☺)Recall first parity violation experiments at acceleratorsDiscuss the family of recent parity violation experiments, what makes them different, what makes them possible?How do we do a parity violation experiment?

Laser table:Lasers (diodes, ti-sap, fiber) (Poelker ☺)Pockels cell properties Pockels cell alignment techniques (Happex method) Laser table components: IA, pzt, insertable halfwave plate, Rotatable HWPPockels cell HV switch (Hansknecht ☺)Comparison of commercial PCs (Cleveland, lasermetrics, 10mm, 20mm, RTP)PZT mirror position feedback (Pitt ☺)Flipping schemes (pairs, quartets), delayed reporting (Pitt ☺)Ground loop management (Hansknecht ☺)Photo-cathodes: types, Residual LP, Analyzing power, QE gradients…

Accelerator:Beam position monitors (Dickson☺)

Beam charge monitorsUsing the bpm system to measure asymmetries (Dickson☺)Beam envelop management at injector (beam through holes) (Kazimi ☺)Beam envelop matching throughout machine, adiabatic damping (Chao☺):

Characterization and control of global transport opticsCorrection of XY coupling and transport singularity from 100 keV to 60 MeVTools and methods for minimizing transport irregularities

Phase Trombone to minimize position differences at target (Bogacz ☺)Halls Crosstalk and beam loadingFeedbackCoil Modulation, Dithering vs. RegressionPosition feedback using helicity magnets (Grames, Suleiman ☺)

Summary: (Armstrong ☺)What has been achieved so far in terms of position differences and charge asymmetries? Future experiments (Qweak and Lead neutron radius) and their requirements, trends and need for continued R&D.

Page 36: JLab Polarized Source

Mott Polarimetry, Load-Lock Gun, and more …

Page 37: JLab Polarized Source

• Upgrade the 5 MeV Mott DAQ: Reduce background and improve the statistical error bar

• Install new 100 keV / 500 keV Mott in Injector in August 07

• Load-Lock Gun will be installed in July 07 (4 photo-cathodes)

• Now running using fiber-lasers

• PC HV Switches and Ground Loop Elimination: (Hansknecht)– Switch Designs

– Eliminating Ringing in Pockels Cells used in Parity experiments

– Ground loop elimination for Parity experiments

http://www.jlab.org/accel/inj_group/laser2001/pockels.htm

Page 38: JLab Polarized Source

G0 Cavities

Page 39: JLab Polarized Source
Page 40: JLab Polarized Source