Jet Cooling English Presentationv2

21
Jet cooling Presentation

Transcript of Jet Cooling English Presentationv2

Page 1: Jet Cooling English Presentationv2

Jet cooling Presentation

Page 2: Jet Cooling English Presentationv2

2

Presentation :

During the cooling phase, the thermal energy contained inside the metal is transferred to the Die through the contact between the die and the metal, as well as through the pins cooling canals.

Precision of the cooling zones as well as the cooling efficiency are essential for the casting quality.

A precise thermal regulation of the Die and its elements allows an optimal casting quality, and solves recurrent metallurgical problems.

Page 3: Jet Cooling English Presentationv2

3

Presentation :

Thermal exchanges between metal and the Die during the solidification phase are directly influenced by certain parameters.

Lifetime of the Die elements, casting quality, as well as process productivity, are all being determined by these parameters.

The use of Jet Cooling is the most effective solution to cool small diameter pins with precision, thus to control material quality problems such as shrinkage and porosity.

Jet Cooling’s main objective is to master and control the heat transfer in the smallest parts of the Die during the aluminium solidification phase.

Page 4: Jet Cooling English Presentationv2

4

General description :

Page 5: Jet Cooling English Presentationv2

5

Pin characteristics:

Range :

-Pins diameter : minimum diameter of 4mm

-Cooling from a drilling diameter of 2mm

-Maximum length of the drilling: 200mm (for a drilling diameter of 2mm)

Page 6: Jet Cooling English Presentationv2

6

Standard pin

Pin with a 2mm diameter drilling

Pin characteristics:

Page 7: Jet Cooling English Presentationv2

7

Jet coolers characteristics:

-Jet cooler internal tube : from 1.2/0.85mm to 2.8/2.3mm

-Jet cooler watertightness at 20 bar : using o’ring or threading

Page 8: Jet Cooling English Presentationv2

8

Cycle Description:

Top injection

Top injection + 3

seconds

Top injection + 23

seconds

Top injection + 43

seconds

Jet cooler empty

before injection

Cooling phase:

Pressure of 15/20

bars

20 seconds

Pressurized air to empty

out the water

Pin breakage control

system

Page 9: Jet Cooling English Presentationv2

9

Jet Cooling goals :

• Advantages :

– Decrease of shrinkages :

Without

Jet cooling

after 50

injections

With

Jet cooling after

5000 injections

The use of Jet cooling in these shrinkage cases allows to maintain a relatively low temperature, thus avoiding any overheating of the pins.

The lifetime of these pins which are subject to high thermal constraints is easily multiplied by 5.

Page 10: Jet Cooling English Presentationv2

10

Jet Cooling goals:

-Improving the castings’ metallurgical quality : decrease of porosity

Page 11: Jet Cooling English Presentationv2

11

Jet Cooling Goals:

Without

Jet coolingWith

Jet cooling

Page 12: Jet Cooling English Presentationv2

12

Jet Cooling Goals:

– Increasing the pins lifetime:

• Average increase : x3 to x5

– Cooling optimization :

• Spray cooling decrease

• Spray cooling zones optimization

• Decrease of the cycle duration

Page 13: Jet Cooling English Presentationv2

13

Applications :

Exemple 1 : Gear box carter

Microscopic inspection is done on the slice ‘A’, with and without the use of Jet Cooling.We can notice smaller-sized grains when using Jet Cooling, thanks to an accelerated solidification phase.

Page 14: Jet Cooling English Presentationv2

14

Applications :

The use of thermal cameras allow us to point out the eiffiency of the cooling on the pins A and B.These pictures are taken before the spray-cooling phase.

The consequence is a 150°C saving on the pins. Furthermore, all the zone around the pins equipped with Jet Cooling also benefits from the cooling impact. This impact is of 70°C.In this example, the cooling time lasts 10 to 15 seconds.

Page 15: Jet Cooling English Presentationv2

15

Applications :

Exemple 2 : Clutch carter

Page 16: Jet Cooling English Presentationv2

16

Applications :

Temperature measurement on the pins equipped with Jet Cooling and before the spray-cooling phase:

Cooling time in seconds

°C

Page 17: Jet Cooling English Presentationv2

17

Applications :

– Results :• Reduction of the cycle duration as well as the spray-cooling phase duration

• Improved castings quality

• Increase of the pins lifetime

• Decrease of shrinkages and porosities

Page 18: Jet Cooling English Presentationv2

18

View of the Dies equipped with jet coolers :

Page 19: Jet Cooling English Presentationv2

19

Ahresty Techno Service Co

- 4 types of cooling capacities : 20pcs, 40pcs, 60pcs, 100pcs of jet coolers

- Pressure max 20 bar

- Flow : max 121 L/min

- Cooling circuits : 6 max

- Max number of jet coolers : 100

Jet cool machine M serie:

Page 20: Jet Cooling English Presentationv2

20

• HDK 4-20 system :

- Pressure : 20 bar

- Flow : 20 L/min

- Cooling circuits : 4

- Water tank : 60L

-Max number of jet coolers : 20

-Advantages :

- Closed water circuit

- Pin breakage control

Jet Cooling machine HDK4:

Page 21: Jet Cooling English Presentationv2

21

References :

• Ahresty group

• Daihatsu motor

• Honda motor

• Isuzu motor

• Mazda motor

• Nissan motor

• Sanden corporation

• Suzuki

• Toyota

• Yamaha

• …

• AE group

• BMW

• CIE Vilanova

• Dacia Renault

• DGH

• Fagor

• Honsel

• MBK

• Rencast

• Renault

• VW

• …

EUROPE ASIA