IsoLoop Isolation Products · 2017-10-05 · ParameterMin.Typ.Max. Units Data Rate 100 110 Mbps PWD...

8
Digital Isolators and Transceivers IsoLoop ® Isolation Products Short-Form Catalog NEW! 6 kV Isolators V.5/17

Transcript of IsoLoop Isolation Products · 2017-10-05 · ParameterMin.Typ.Max. Units Data Rate 100 110 Mbps PWD...

Page 1: IsoLoop Isolation Products · 2017-10-05 · ParameterMin.Typ.Max. Units Data Rate 100 110 Mbps PWD 3 ns Propagation Delay 10 15 ns Propagation Delay Skew 4 6 ns Pulse Jitter 100

Digital Isolators and Transceivers

IsoLoop®

IsolationProducts

Short-FormCatalog

NEW!6 kV

Isolators

ISB-CB-002-01-V.qxd 3/24/2017 8:18 PM Page 1

V.5/17

Page 2: IsoLoop Isolation Products · 2017-10-05 · ParameterMin.Typ.Max. Units Data Rate 100 110 Mbps PWD 3 ns Propagation Delay 10 15 ns Propagation Delay Skew 4 6 ns Pulse Jitter 100

Parameter Min. Typ. Max. UnitsData Rate 100 110 Mbps

PWD 3 ns

Propagation Delay 10 15 ns

Propagation Delay Skew 4 6 ns

Pulse Jitter 100 ps

Quiescent Supply Current 1.3 1.8 mA/ch

Transient Immunity 30 50 kV/µs

Isolation Voltage 2.5 kVRMS

Operating Temperature –40 +125 °C

IL810

IL814

IL821IL815

IL816

IL811

IL817

OUT1IN1

IN1

IN2

OUT1

OUT2

VOE OUT1

OUT2

IN1

IN2

IN3OUT3

VOE

IN1

IN2

OUT3

OUT4

OUT1

OUT2

IN3

IN4

OUT1

OUT2

OUT3

OUT4

IN1

IN2

IN3

IN4

VOE

IN1OUT1

OUT2IN2

OUT3IN3

IN4OUT4

IN1

IN2

OUT1

OUT2

New IL800T-Series Digital Isolators are best-in-class for speed,temperature, and other performance parameters.

Popular applications include serial interfaces, isolated SPI, andisolated A/D converters.

Features:• 100 Mbps • 125°C • DC-correct • Excellent magnetic immunity• VDE V 0884-10 certified and UL 1577 recognized • Working Voltage (VIORM) 600 VRMS per VDE V 0884-10• True 8 mm creepage wide-body packages per IEC 60601

IL800T-Series Top-of-the-Line IsolatorsBest Speed, Temperature, and Performance

ISB-CB-002-01-V.qxd 3/24/2017 8:19 PM Page 2

Page 3: IsoLoop Isolation Products · 2017-10-05 · ParameterMin.Typ.Max. Units Data Rate 100 110 Mbps PWD 3 ns Propagation Delay 10 15 ns Propagation Delay Skew 4 6 ns Pulse Jitter 100

Parameter Min. Typ. Max. UnitsData Rate (Std./S-Series) 100 / 130 110 / 150 Mbps

PWD (Std./S-Series) 3 / 0.3 3 ns

Propagation Delay Skew 4 6 ns

Pulse Jitter 100 ps

Quiescent Supply Current 1.2 1.75 mA/ch

Isolation (Standard/VE-Series) 2.5 / 6 kVRMS

Transient Immunity 30 50 kV/µs

Op. Temp. (Std./T or VE-Series) +100 / +125

IL200 Series–40

+85°C

IL700/IL200 Series High-Performance IsolatorsVersatile Workhorse Isolators

OUT1

VOE

IN1

IL710

OUT1

OUT2

OUT3

OUT4

OUT5

IN1

IN2

IN3

IN4

IN5

IL260

IN1

IN2

IN3

IN4

OUT5 IN5

OUT1

OUT2

OUT3

OUT4

IL261

IL711

IL712

IN1

IN2

OUT1

OUT2

OUT1

IN2OUT2

IN1

IL721

IN1

OUT2IN2

OUT1 IL717

OUT1

OUT2

OUT3

IN4

IN1

IN2

IN3

OUT4

IL715

OUT1

OUT2

OUT3

OUT4

IN1

IN2

IN3

IN4

IL716

IN1

IN2

OUT3

OUT4

OUT1

OUT2

IN3

IN4

IN1

IN2

IN3

OUT4

OUT5 IN5

OUT1

OUT2

OUT3

IN4

IL262

Award-winning IL700/IL200-Series DigitalIsolators provideperformance andflexibility, includinghighest data rates, smallestpackages, lowest distortion, low powerconsumption, and 44000-year barrier life.

High-voltage V-Series versions have extremely high isolationvoltages of 6 kVRMS in wide-body packages and 2.5 kVRMS inMSOPs. Wide-body V-Series versions are rated at a remarkable1000 VRMS Working Voltage and 12.8 kV surge immunity.

Popular IL700/IL200 applications include serial interfaces,isolated SPI, and switch-mode power supplies.

Features:• No carrier or clock for low emissions and high immunity• Excellent magnetic immunity• World’s smallest isolators available (MSOP8 and QSOP16)• Highest isolation voltage (6 kVRMS)• Fastest (to 150 Mbps) and lowest PWD (300 ps)• VDE V 0884-10 certified; UL 1577 recognized • True 8 mm creepage wide-body packages per IEC 60601

NEW!6 kV

Isolators

ISB-CB-002-01-V.qxd 3/24/2017 8:21 PM Page 3

Page 4: IsoLoop Isolation Products · 2017-10-05 · ParameterMin.Typ.Max. Units Data Rate 100 110 Mbps PWD 3 ns Propagation Delay 10 15 ns Propagation Delay Skew 4 6 ns Pulse Jitter 100

Model Bus Inputs Mbps Nodes Bus ESD Key Features Available PackagesIL41050TT CAN Digital 1 110 4 kV Low Cost 0.3" SOIC16

IL41050TA CAN Digital 1 110 4 kV 125°C; Silent Mode QSOP16; 0.15" SOIC16; 0.3" SOIC16

IL3122 RS-422 Passive 5 32 15 kV Low Cost 0.15" SOIC16; 0.3" SOIC16

IL3185 RS-485 Passive 5 32 15 kV Low Cost 0.15" SOIC16; 0.3" SOIC16

IL3222 RS-422 Passive 5 256 15 kV Fractional Load 0.15" SOIC16; 0.3" SOIC16

IL3285 RS-485 Passive 5 256 15 kV Fractional Load 0.15" SOIC16; 0.3" SOIC16

IL3422 RS-422 Passive 20 32 15 kV High Speed 0.15" SOIC16; 0.3" SOIC16

IL3485 RS-485 Passive 20 32 15 kV High Speed 0.15" SOIC16; 0.3" SOIC16

IL422 RS-422 Digital 25 32 15 kV Legacy Standard 0.3" SOIC16

IL485 RS-485 Digital 35 32 2 kV Legacy Standard 0.3" SOIC16

IL485W RS-485 Digital 35 32 2 kV Handshake Line 0.3" SOIC16

IL3022 RS-422 Digital 4 32 7.5 kV Low Cost 0.3" SOIC16

IL3085 RS-485 Digital 4 32 15 kV Low Cost QSOP16; 0.15" SOIC16; 0.3" SOIC16

IL3522 RS-422 Digital 40 50 15 kV Very High Speed 0.3" SOIC16

IL3585 RS-485 Digital 40 50 15 kV Very High Speed 0.15" SOIC16; 0.3" SOIC16

IL3685 RS-485 Digital 40 50 15 kV PROFIBUS QSOP16; 0.15" SOIC16; 0.3" SOIC16

IL400, IL3000, and IL41050 SeriesSingle-Chip Isolated Network Transceivers

NVE offers a broad range of isolated RS-422, RS-485and CAN network transceivers. All have excellent EMCfootprints, 50 kV/µs typical transient immunity, andvirtually unlimited barrier life.

High-voltage V-Series versions have 6 kVRMS isolationvoltage. Standard isolation voltage is 2.5 kVRMS.Standard versions are rated for 600 VRMS WorkingVoltage per VDE V 0884-10; V-Series versions for1000 VRMS Working Voltage.

Versions are available in unique 0.15-inch SOIC andQSOP packages, as well as true 8 mm creepage0.3-inch SOICs, making these the most compactsolutions in the world while still meeting isolationvoltage creepage and clearance safety standards.

All transceivers are VDE V 0884-10 certified andUL 1577 recognized; IL41050 models are ISO 11898compliant; the IL3685 is PROFIBUS compliant.

R

RE

IL3122 / IL3222 / IL3422

AVCOIL2

VCOIL1

DE

D

B

YZ

R

RE

IL3185 / IL3285 / IL3485

AVCOIL2

VCOIL1

DE

D

B

ISODE

A

Z

DE

D

R

RE

Y

IL422 / IL3522

B

TxD

RxD

CANH

CANL

IL41050TT

ISODE

A

IN1

DE

D

RRE

OUT1

IL485W

B

DE

D

R

RE

ISODE

AB

IL485 / IL3085 /IL3585 / IL3685

NEW!QSOPs

NEW!6 kV

TxD

RxD

CANH

CANL

IL41050TA

S

VREF

ISB-CB-002-01-V.qxd 3/24/2017 8:25 PM Page 4

Page 5: IsoLoop Isolation Products · 2017-10-05 · ParameterMin.Typ.Max. Units Data Rate 100 110 Mbps PWD 3 ns Propagation Delay 10 15 ns Propagation Delay Skew 4 6 ns Pulse Jitter 100

IL500 Series 2 Mbps IsolatorsThe Cost-Effective Alternative

IL500-Series Isolators are NVE’s lowest-cost isolators. One, two, three, or fourchannel configurations; SOIC or unique MSOP packages. An internal refresh clockensures DC-correct operation.

Popular IL500-Series applications include isolated A/D and D/A converters, serialinterfaces, isolated SPI, and power interfaces.

Features:• 2 Mbps• 10 ns pulse-width distortion• DC correct• Working Voltage 600 VRMS per VDE V 0884-10• –40°C to +85°C operating range• 44000-year barrier life• MSOP and SOIC packages

IL516

IN1

IN2

OUT3

OUT4

OUT1

OUT2

IN3

IN4

OUT1IN1

IL510

IL511

IN1

IN2

OUT1

OUT2

VOE

IL514

OUT1

OUT2

IN1

IN2

IN3OUT3

VOE

IL515

OUT1

OUT2

OUT3

OUT4

IN1

IN2

IN3

IN4

VOE

IL521

OUT1

IN2

IN1

OUT2

Parameter Min. Typ. Max. UnitsData Rate 2 Mbps

Pulse Width Distortion 10 ns

Propagation Delay 25 ns

Propagation Delay Skew 10 ns

Transient Immunity 30 50 kV/µs

Temperature Range –40 +85 °C

ISB-CB-002-01-V.qxd 3/24/2017 8:29 PM Page 5

Page 6: IsoLoop Isolation Products · 2017-10-05 · ParameterMin.Typ.Max. Units Data Rate 100 110 Mbps PWD 3 ns Propagation Delay 10 15 ns Propagation Delay Skew 4 6 ns Pulse Jitter 100

Parameter Min. Typ. Max. UnitsData Rate (Standard / A-Series) 100 / 10 Mbps

Pulse Width Distortion 3 5 ns

Propagation Delay 8 15 ns

Propagation Delay Skew 4 6 ns

Transient Immunity 15 20 kV/µs

Temperature Range –40 +85 °C

IL600 and IL600A Passive Input IsolatorsThe Opto AlternativeSM

Unique IL600 and IL600A Series Isolators have passive inputsfor flexibility similar to LED-input optocouplers. The IL600-Series has CMOS outputs and the IL600A-Series has open-drain outputs.

Unlike other isolators, the IL600/IL600A Series can beconfigured for inverting or non-inverting inputs.

The IL600 and IL600A-Series Isolators are available in PDIP,SOIC, and unique MSOP packages. Parts are also available asbare die for chip-on-board assembly.

Popular IL600/IL600A Series applications include isolatedPLCs, serial interface receivers, I²C, isolated CAN Bus, andwired-OR controls.

Features:• Failsafe operation• DC correct• 5 mA input current• No carrier or clock for low EMI emissions and susceptibility• 3.3 V or 5 V supply• 2.5 mA dynamic input current (50% duty cycle) • VDE V 0884-10 certified; UL 1577 recognized • 44000-year barrier life• PDIP, SOIC, MSOP, or bare die

OUT1

VOE

OUT1

OUT2

OUT1

IN2

OUT1

OUT2

OUT3

IN1

IN1

IN2

IN1

OUT2

IN1

IN2

IN3

VDD1

VDD2

IL610

IL611

IL612

IL613

IL614

OUT1

IN2

IN3

IN1

OUT2

OUT3

COIL

RE

IN1OUT2

IN1

IN1

IN2

GND

OUT1

IN2

VOE

OUT1

GND

OUT1

OUT2

GND

GNDVDD2

VDD1

IL610A

IL611A

IL612A

ISB-CB-002-01-V.qxd 3/24/2017 8:31 PM Page 6

Page 7: IsoLoop Isolation Products · 2017-10-05 · ParameterMin.Typ.Max. Units Data Rate 100 110 Mbps PWD 3 ns Propagation Delay 10 15 ns Propagation Delay Skew 4 6 ns Pulse Jitter 100

Illustrative Applications

Visit www.nve.com for more IsoLoop Isolator circuits.

Multi-Channel Isolated Sampling A/D Converter Using IL261The IL261 is ideal for isolating multi-channel sampling ADCs. Isolatedchannels A0 and A1 control the analog channel being sampled, whilethe three remaining I/O lines on the IL261 isolate the SPI interface.

Data Clock

Iso SD Out

Iso Data Clock

IL261

Sampling ADC

IsolationBoundary

ADS7825

Channel A1

Serial Data Out

R/C

Channel A0

Iso Ch A1

Iso Ch A0

Iso Read/Conv

Analog Ch 0

Analog Ch 1

Analog Ch 2

Analog Ch 3

Switch-Mode Power Supply With 2.5 kV MSOP IsolatorsV-1 Series MSOP isolators can be used for both can synchronous rectification and voltage feedback isolation to shrink Switch ModePower Supplies. Using the IL710V-1 for voltage feedback instead of a linear optocoupler eliminates a major reliability problem.

PWM Controller

VIN

VOUT

Err

orA

mpl

ifier

Volta

geR

efer

ence

IsolationBarrier

IL710V-1

IL711V-1

One-Shot FrequencyConvertor

Voltage-to-

ISB-CB-002-01-V.qxd 3/24/2017 8:33 PM Page 7

Page 8: IsoLoop Isolation Products · 2017-10-05 · ParameterMin.Typ.Max. Units Data Rate 100 110 Mbps PWD 3 ns Propagation Delay 10 15 ns Propagation Delay Skew 4 6 ns Pulse Jitter 100

Limited Warranty and LiabilityInformation in this document is believed to be accurate and reliable. However, NVE does not give any representations or warranties, expressed or implied, as to theaccuracy or completeness of such information and shall have no liability for the consequences of use of such information.

In no event shall NVE be liable for any indirect, incidental, punitive, special or consequential damages (including, without limitation, lost profits, lost savings, businessinterruption, costs related to the removal or replacement of any products or rework charges) whether or not such damages are based on tort (including negligence),warranty, breach of contract or any other legal theory.

Right to Make ChangesNVE reserves the right to make changes to information published in this document including, without limitation, specifications and product descriptions at any time andwithout notice. This document supersedes and replaces all information supplied prior to its publication.

Use in Life-Critical or Safety-Critical ApplicationsUnless NVE and a customer explicitly agree otherwise in writing, NVE products are not designed, authorized or warranted to be suitable for use in life support, life-critical or safety-critical devices or equipment. NVE accepts no liability for inclusion or use of NVE products in such applications and such inclusion or use is at thecustomer’s own risk. Should the customer use NVE products for such application whether authorized by NVE or not, the customer shall indemnify and hold NVEharmless against all claims and damages.

ApplicationsApplications described in this document are illustrative only. NVE makes no representation or warranty that such applications will be suitable for the specified use withoutfurther testing or modification.

Customers are responsible for the design and operation of their applications and products using NVE products, and NVE accepts no liability for any assistance withapplications or customer product design. It is customer’s sole responsibility to determine whether the NVE product is suitable and fit for the customer’s applications andproducts planned, as well as for the planned application and use of customer’s third party customers. Customers should provide appropriate design and operatingsafeguards to minimize the risks associated with their applications and products.

NVE does not accept any liability related to any default, damage, costs or problem which is based on any weakness or default in the customer’s applications or products,or the application or use by customer’s third party customers. The customer is responsible for all necessary testing for the customer’s applications and products using NVEproducts in order to avoid a default of the applications and the products or of the application or use by customer’s third party customers. NVE accepts no liability in thisrespect.

Terms and Conditions of SaleIn case an individual agreement is concluded only the terms and conditions of the respective agreement shall apply. NVE hereby expressly objects to applying thecustomer’s general terms and conditions with regard to the purchase of NVE products by customer.

No Offer to Sell or LicenseNothing in this document may be interpreted or construed as an offer to sell products that is open for acceptance or the grant, conveyance or implication of any licenseunder any copyrights, patents or other industrial or intellectual property rights.

Export ControlThis document as well as the items described herein may be subject to export control regulations. Export might require a prior authorization from national authorities.

Automotive Qualified ProductsUnless the datasheet expressly states that a specific NVE product is automotive qualified, the product is not suitable for automotive use. It is neither qualified nor tested inaccordance with automotive testing or application requirements. NVE accepts no liability for inclusion or use of non-automotive qualified products in automotiveequipment or applications.

In the event that customer uses the product for design-in and use in automotive applications to automotive specifications and standards, customer (a) shall use the productwithout NVE’s warranty of the product for such automotive applications, use and specifications, and (b) whenever customer uses the product for automotive applicationsbeyond NVE’s specifications such use shall be solely at customer’s own risk, and (c) customer fully indemnifies NVE for any liability, damages or failed product claimsresulting from customer design and use of the product for automotive applications beyond NVE’s standard warranty and NVE’s product specifications.

An ISO 9001 Certified Company

NVE Corporation11409 Valley View RoadEden Prairie, MN 55344-3617 USA(952) [email protected]

On the CoverIsoLoop Isolation Products help make a digital world practical. Approximately 750 actual-size IsoLoop 8-pin MSOPIsolators form the image on the front and back spine of this catalog. NVE is the leader in isolator miniaturization with afull line of MSOP, QSOP, and narrow-body parts.

ISB-CB-002-01-VApril 2017

©NVE CorporationAll rights are reserved. Reproduction in whole or in part is prohibited without the prior written consent of the copyright owner.

ISB-CB-002-01-V.qxd 3/24/2017 8:35 PM Page 8