Internal usage only Nestle Chembong – IND780 Q.i System Overview.

3
Internal usage only Nestle Chembong – IND780 Q.i System Overview BATCH W EIGHER PC w ith HM Isoftw are C ontrolN etnetwork 4~20m A 780 Q i VSD ’s Enable signal Inverter / Variable Speeds D rive (VSD ) > 3-phase pow ersupply to all screw conveyors > Speed is varies by 4~20m A (P LC ) > Enable-R unning signal is controlled by IN D 780 Q I FCE signal FCE output FC E and FAST Feed D iscrete O utputs Com ponentB C om ponentC Com ponentA Com ponentF C om ponentD Com ponentE

Transcript of Internal usage only Nestle Chembong – IND780 Q.i System Overview.

Page 1: Internal usage only Nestle Chembong – IND780 Q.i System Overview.

Internal usage only

Nestle Chembong – IND780 Q.iSystem Overview

BATCH WEIGHER

PC withHMI software

ControlNet network

4~20mA

780 QiVSD’s

Enable signal

Inverter /Variable Speeds Drive (VSD)

> 3-phase power supply to all screw conveyors > Speed is varies by 4~20mA (PLC) > Enable-Running signal is controlled

by IND780 QI FCE signalFCE output

FCE and FAST Feed Discrete Outputs

Component B Component CComponent A Component FComponent D Component E

Page 2: Internal usage only Nestle Chembong – IND780 Q.i System Overview.

Internal usage only

ControlLogix PLC will handle Recipe from HMI – PC Only one component is being filled at one time Feed command is issued by the ControlLogix PLC through the AIM interface driver to

the IND780 Q.i terminal utilizing a ControlNet connection The IND780 Q.i terminal controls the material transfer for each component using

patented, auto tuning Predictive Adaptive Control feed algorithms (PAC algorithms) Feed status information is returned by the IND780 Q.i terminal to the ControlLogix

PLC through the AIM interface driver and the same ControlNet connection The screw conveyor cut off is controlled by the Final Control Element (FCE) output in

the IND780 Q.i terminal. The FCE is connected directly to VSD / inverter enable / Run signal

At the same time, the FCE and fast feed discrete outputs from the IND780 Q.i terminal are connected to ControlLogix’s discrete inputs

From the FCE and fast feed signals, ControlLogix will manipulate 4~20 mA signal to control VSD’s speed

Each component will have unique material path configuration feed parameters in the IND780 Q.i terminal and ControlLogix PLC (4~20 mA settings)

The IND780 Q.i terminal updates it’s material path feed parameters after every component feed. These parameter updates are then used by the PAC algorithm for the next component feed and optimized control of the FCE (fast and accurate fill)

Nestle Chembong – IND780 Q.i

Data Brief

Page 3: Internal usage only Nestle Chembong – IND780 Q.i System Overview.

Internal usage only

Overall: ~ 50 Batches of actual Batching was performed under 780 Qi mode. System is still under testing and commissioning. More testing is required to finalize material path setting.

Throughput: Overall system batching time has been reduced from ~ 6 minutes per

batch to ~ 5 minutes per batch. This is ~ 17 % reduction of overall batching time.

Accuracy: For high capacity target, system is performing well. Having accuracy within ~ 1 kg. For low capacity target with low density material, process / system

performance still affecting the final accuracy. System is been modified and need further testing and tuning to enhance

final accuracy.

Nestle Chembong – IND780 Q.i

Testing Result