Instruction Manual ATN X-Sight HD Series Weapon Sights | Optics Trade

12
user’s guide AMERICAN TECHNOLOGIES NETWORK CORP. X-Sight HD Series X-SIGHT USER’S GUIDE (REV. 1, JULY, 2014) DAY/NIGHT WEAPON SIGHTS

Transcript of Instruction Manual ATN X-Sight HD Series Weapon Sights | Optics Trade

u s e r ’ s g u i d e

AMERICANTECHNOLOGIES

NETWORKCORP.

X-Sight HD Series

X-SIGHT USER’S GUIDE (REV. 1, JULY, 2014)

DAY/NIGHT WEAPON SIGHTS

THIS PRODUCT CONTAINS NATURAL RUBBER LATEX WHICH MAY CAUSE ALLERGIC REACTIONS.CAUTION:

The information in this manual furnished for information use only, is subject to change without notice, is not to be construed as a commitment by ATN Corp.

ATN Corp. assumes no responsibility or liability for any errors or inaccuracies that may appear in this book.

©2014 ATN Corp. All right reserved.

Register your product warranty online at www.atncorp.com/warranty

PICATINNY RAIL

DIOPTER ADJUSTMENT

MOUNTING SYSTEM

FOCUS ADJUSTMENT KNOB

BATTERY HOUSING CAP

RIGHT ARROW BUTTON

ENTER BUTTON

POWER BUTTON

LEFT ARROW BUTTON

UP ARROW BUTTON

DOWN ARROW BUTTON

MicroSD, MicroHDMI & MicroUSB

X-Sight HD 5-18

X-Sight HD 3-12 850 mW Infra-red illuminator

(included)

2

APPLICATIONCome see the latest in Smart HD Optics.The ATN X-Sight weapon scopes are powered by the new revolutionary ATN Obsidian Core that runs a suite of sensors to cover all your needs. Perfect clarity in day or night, GPS, Geotag, WiFi, E-zoom, Record HD Video/Images, Compass, Gyroscope, and much more.X-Sight — the weapon scope for the 21st century.

SPECIFICATIONS

ATN X-Sight 3-12x ATN X-Sight 5-18x

Generation Smart HD Optics

Magnification 3-12x 5-18x

Eye relief 67 mm

Built-in IR detachable

Sensor HD 1080p ATN L130 Sensor

Display 800 x 600 px

Diopter adjustment ±5

Ports Micro HDMI Output, Micro USB

Power 4 AA type batteries

SD Card 4 to 32 Gb

Video Out 1080p at 30fps & 720 at 60fps

Remote View Finder via IOS or Android app

Dimensions 9,5” x 3.25” x 3.13” / 238 x 83 x 79 mm

10.3” x 3.5” x 3.2” 262 x 88 x 82 mm

Weight 2.3 lb/ 1.05kg 2.7 lb/ 1.22 kg

* ATN reserves the right to change the above specifications at any time without notice

• Day / night• WiFi• Record video / Capture Pictures• GPS• Image stabilization/gyroscope

• E-compass• Altitude• Velocity• E-Zoom• Geotag

FEATURES

3

PREPARATION FOR OPERATION This chapter contains the information necessary to prepare the scope for operation. This includes un-packing, examination for damage, and batteries installation.

a. UnpackingThe following steps must be accomplished prior to each mission where the sight is used.

1. Open carrying case, remove the scope and check contents for completeness.

2. Inspect the scope for obvious evidence of damage to optical surfaces, body, eyecups, operation buttons, etc. Ensure that all optical surfaces are clean and ready for use. Clean with lens tissue.

b. Installation of BatteriesThe X-Sight HD will operate with four AA batteries type.

Install AA batteries as follows:

1. Remove the battery cap by unscrewing it counter clockwise.

2. Insert batteries as shown.

3. Replace battery cap into the housing. Screw clock-wise until finger tight. Do not over tighten as it will be difficult to remove the next time you replace batteries.

c. Ports and and their usingNOTE: You must have an SD card inserted in the device in order to be able to update the scope with the latest firmware as well as utilize the WiFi mode.

X-Sight HD has Micro SD, Micro USB and MicroHDMI ports.

Insert MicroSD card as follows:

1. Remove X-Sight HD has Micro SD, Micro USB and MicroHDMI ports cap by unscrewing it counter clockwise. Assure that the X-Sight power is turned OFF before inserting the card into the slot.

2. Insert Micro SD card as shown.

3. Replace port cap into the housing. Screw clockwise until finger tight. Do not over tighten as it will be difficult to remove.

NOTE1. There is only one correct direction to insert the Micro SD card. Do not force the card into the slot as it may damage both the camera and the Micro SD card. Insert the card, as indicated.2. A new Micro SD card should be formatted before using.

OPERATINGMOUNTING

1. Slightly loosen the fixing screws on the 7/8” weaver mount built into the scope.2. Place the scope on the weaver rail of the fire arm.3. Tighten the fixing screws.

NOTE: Fixing screws may need to be tightened after continuous shooting.

Micro SD PORT

Micro USB PORTMicroHDMI PORT

4

MOUNTING SYSTEMThe ATN Night Vision Riflescopes Mounting System allows to change the position of the riflescope flexibly on the weapon in relation to a shooter in combination with the fixed positions already available on the weaver rail. For this purpose in the base of the mounting bracket there is a rail with a fixing projection. There are two grooves in the mounting bracket for mounting this rail. Besides it is possible to change the position of the riflescope additionally by 1/3 of inch. For doing this one needs to about-face the rail.To change the position of the riflescope on the weaver rail additionally follow the steps mentioned below:1. Unscrew the two screws, which attach the rail to the mounting bracket.2. Take the rail out of the groove.3. About-face the rail in case of necessity.4. Place the rail into another groove.5. Fix the rail with the two screws.

NOTE: If the rail does not come out easily, tighten one of the removed screws into the threaded aperture in the middle of the fixing projection of the rail. Rotate this screw, which will in turn push the rail out from the groove.

CONTROLThis section contains operating procedures for using the X-Sight as weapon sight. Prior to operating the sight, make certain that all the steps in “Preparation for operation”, have been read and performed.1. TURNING ON

Open the objective lens cover. The objective lens cover protects the monocular from inadver-tent exposure to extremely high levels of radiant flux. Never leave the sight with the objective lens cover off. To turn the unit press POWER button.

2. MENU SETSTo access the settings, you need to double press ENTER. After that we get to the shortcuts screen (Figure B), using the RIGHT-LEFT buttons highlight MENU and press ENTER, to go to the main MENU (Figure C).

GROOVERAIL WITH A FIXING PROJECTION

SCREWS

MOUNTING SYSTEM

FIGURE A. OPERATIONAL BUTTONS OF X-SIGHT

ENTER BUTTON

RIGHT BUTTON

DOWN BUTTON

UP BUTTON

LEFT BUTTON

5

a. Display Menu setSelect the item Display by using UP-DOWN arrow keys, and press ENTER. Display settings appears (Figure D).

FIGURE B. SHORTCUTS SCREEN

FIGURE C. MENU

FIGURE D. DISPLAY SETTINGS

6

Select the desired setting by using the UP-DOWN arrow keys. If there is a small white arrow right of the title, then by pressing ENTER, we move to the submenu. If on the right of the options we see the option value, then you can use the RIGHT arrow or ENTER, in order to get there.Let’s look at all options in order.

1) Return — press ENTER and go back to the initial screen.

NOTEIt also works for all other submenu. Also exit the submenu, if you hold press LEFT arrow.

2) Day / Night mode — press ENTER and turn to your day and night modes (Figures E and Figure F). Press the arrow DOWN, line Day / Night mode is highlighted and activate option value right with ENTER or RIGHT arrow. Select the option value — DAY or NIGHT with UP-DOWN arrow keys.

• Night Mode Color — Green/White.• Light Amplification — values High/Medium/Low.

3) Brightness — ENTER or RIGHT arrow activates option value and UP-DOWN arrows select the brightness value from 1 to 5.

4) Reticle — press ENTER and enter the reticle settings (Figure G).• Reticle display — ON/OFF.

FIGURE E. DAY/NIGHT MODE (DAY)

FIGURE F. DAY/NIGHT MODE (NIGHT)

7

• Reticle image — press ENTER to open the selection screen of the reticle image (Figure H). With LEFT-RIGHT and UP-DOWN arrow keys, select the reticle image and press ENTER to fix selection.

• Zoom position — activate option value right with ENTER or RIGHT arrow. Select the option value — CENTER or RETICLE with UP-DOWN arrow keys.

FIGURE G. RETICLE SETTINGS

FIGURE H. RETICLE IMAGE

FIGURE I. ZERO SETUP

8

• Zero setup — press ENTER to open Zero setup screen (Figure I). With LEFT-RIGHT and UP-DOWN arrow keys we move the reticle. Press ENTER to fix reticle position. Hold press Enter to reset reticle position.

5) Shortcuts — press ENTER and enter the settings (Figure J). RIGHT arrow activates values on the right. Use arrows UP-DOWN to select the option values:

• Capture — ON/OFF;• Brightness — ON/OFF;• Day/Night — ON/OFF.

6) Compass position — arrow RIGHT activates right option value and with arrows UP-DOWN select the value TOP, BOTTOM or NONE.

7) Speedometer position — RIGHT arrow activate right option value and with arrows UP-DOWN choose the value TOP, BOTTOM or NONE.

8) Altitude position — RIGHT arrow activates right option value and with arrows UP-DOWN choose the value TOP, BOTTOM or NONE.

9) Clock position — RIGHT arrow activates right option value and with arrows UP-DOWN choose the value TOP, BOTTOM or NONE.

10) Display bottom banner for (sec) — RIGHT arrow activates right option value and with arrows UP-DOWN choose values 2-10.

FOCUSINGModel X-Sight HD 3-12 has a fixed focal length. Model X-Sight HD 5-18 focuses as follows:To focus the scope you need to adjust the diopter first. Simply turn the diopter clockwise until it stops. Then concentrate on any object and slowly turn the diopter back counter clockwise until the grain in the image is sharp. You scope has ability to focus either long range or short. Focus the front lens by rotating the ring until the im-age and the grain are both sharp. When you are in the low-light conditions and the daylight filter is off you may focus the front lens to receive a sharp image, the diopter should not be adjusted.

FIGURE J. SHORTCUTS

FOCUS ADJUSTMENT RING

9

OPERATION EXTENSIBILITYThere is Picatinny rail on the body of the scope for additional lighting, laser and other mission critical tools.

LONG RANGE 850 mW INFRA-RED ILLUMINATORInfra-red (IR) Illuminators are common for night vision technology. The IR light greatly enhances the performance of your device, while remaining almost totally invisible to the naked eye. Staying in the dark, switch on your night vision device. If the visibility is low, you may use ATN IR850 to improve the situation. Still, you should remember that the IR illuminator is just a source of infrared light so the greater is the chosen range of observation, the lesser its bright-ness becomes.

BATTERY HOUSING

FIXING NUT

IR ELEVATION ADJUSTMENT

IR WINDAGE ADJUSTMENTIR FOCUSING

NUT

POWER LED INDICATOR

ALLEN KEY

WRENCH

IR BRIGHTNESS ADJUSTMENT

BATTERY HOUSING

CAP

The ATN IR850 is powered with two CR123A lithium batteries To install batteries unscrew the cap of the battery housing and insert batteries following the polarity arrows marked on the housing. Put the cap in place.The IR850 illuminator has a control panel with two buttons. To switch the IR illumina-tor on/off press “+” and “-” buttons simultaneously. When the IR illuminator is switched on you can see the green LED lit on the back side of IR850. By pushing the buttons “+” and “-” you may adjust the IR brightness.The IR beam is focusable to change the field of coverage. To change the beam width slightly turn the IR lens.You may need adjust the focusing of the IR beam to change the field of coverage. Do it by slightly rotating the IR lens. The windage and elevation screws help adjust the direction of the IR beam from the IR850 in order to focus on the scene observed in the viewfinder of your NVD. Use the included Allen wrench to rotate the adjust-ing screws until the IR beam is centered. Please remem-ber the adjustments should be performed under night light conditions only.You can change the position of the IR control panel to meet your your needs. The wrench that is included in the set, is used to loosen the nut located on the body of the IR. Rotate the IR to the desired position. Tighten the nut with the wrench to secure the new position.

NUT

CONTROL PANEL

WRENCH

TO TIGHTEN NUT

TO LOOSEN NUT

10

031

0201

4

WARNINGS AND CAUTIONS• Always remember to turn off the X-Sight when it is not in use. If you do not plan on using your scope for a period of more than 10 days, you should remove the batteries. • Keep lens cap on when not in use.• Avoid contact with dust, steam, and gas.• The scope is not harmful to the user or the environment.• Do not disassemble: it will void your warranty.• Evaluate the scopes function by looking through it in a lit environment with the lens cap put

on. • Adverse atmospheric conditions such as fog, smog, or haze and a lack of ambient light

(moon or starlight) may diminish the effective viewing distance. All technical data for this unit was compiled in a controlled environment.

• This product contains natural rubber latex which may cause allergic reactions.

WARRANTYPlease visit www.atncorp.com/warranty for warranty details and information.

Please make sure the create a separate warranty file that can be downloaded inside the Sup-port Download section of the device. Also, please make sure to take out all references of Void-ing warranty if the device is used during Daytime Operation.

©2014 ATN Corporation

For customer service and technical support, please contact

American Technologies Network Corp.

1341 San Mateo Avenue, South San Francisco, CA 94080

phone: 800-910-2862, 650-989-5100; fax: 650-875-0129

www.atncorp.com