Installation, Operation and Maintenance Manual · 2018. 7. 6. · PIR Series 6 Installation,...
Transcript of Installation, Operation and Maintenance Manual · 2018. 7. 6. · PIR Series 6 Installation,...
Installation, Operation and Maintenance ManualPIR Series
Installation, Operation and Maintenance Manual | PIR Series 1VERSION 1
PIR Series
REVISION REGISTER
Version Details of Update Date
1 Original document creation 07/06/2018
PIR Series
2 Installation, Operation and Maintenance Manual | PIR Series VERSION 1
TABLE OF CONTENTS
SECTION 1: PRODUCT SPECIFICATION .................................................................................................. 3
Raceway Specification ............................................................................................................... 4
SECTION 2: PRODUCT SELECTION GUIDE ........................................................................................... 9
PIR Power System Layout Drawing .......................................................................................10
PIR Power Product Selection Guide.....................................................................................11
PIR Power & Data System Layout Drawing .........................................................................24
PIR Power & Data Product Selection Guide .......................................................................25
PIR Cabinet Busway System Layout Drawing ................................................................... 40
PIR Cabinet Busway Product Selection Guide ..................................................................41
SECTION 3: INSTALLATION INSTRUCTIONS .......................................................................................45
Installation Instructions ............................................................................................................ 46
Installing a Plug-In Module ..................................................................................................... 48
Removing a Plug-In Module ................................................................................................... 49
SECTION 4: FIELD SERVICES AND WARRANTY ................................................................................51
Universal Global Services ........................................................................................................52
Standard Factory Warranty ..................................................................................................... 54
Standard Factory Warranty Process .................................................................................... 54
SECTION 5: MAINTENANCE ........................................................................................................................55
Starline Raceway Recommended Maintenance ................................................................ 56
Installation, Operation and Maintenance Manual | PIR Series 3VERSION 1
PIR SeriesPRODUCT SPECIFICATION
1Section 1Product Specification
PIR Series
4 Installation, Operation and Maintenance Manual | PIR Series VERSION 1
PRODUCT SPECIFICATION
RACEWAY SPECIFICATION
1 SUMMARY
1.1 This specification covers the electrical characteristics and general requirements for a Plug-In Raceway system.
1.1.1 Starline Plug-In Raceway, hereafter referred to as ‘Raceway’, is an electrical system using a continuous plug-in busway design with an enclosed pathway for power distribution and communication wiring. Plug-in modules contain receptacles to provide power with/without circuit protection at the point of use. Plug-in modules can be added to or removed from the Raceway without shutting down power, as designed for energized insertion per UL857. The Raceway also has an optional channel to run cabling for voice, data, multi-media, low voltage, and optical fiber cables or other similar items.
2 STANDARDS
2.1 Raceway is designed and manufactured to the following standards:
2.1.1 Underwriters Laboratories Standard, UL 857 – The common UL, CSA, and ANCE Standard for Busway that is derived from the fifth edition of CSA Standard C22.2 No. 27, the twelve edition of UL 857, and the second edition of NMX-J-148-1998-ANCE
2.1.2 National Electric Code (NEC) – Article 368 – Busway
2.1.3 National Electric Code (NEC) Article 386 Surface Metal Raceways
2.1.4 cETLus
2.1.5 NFPA 70 – National Fire Protection Agency
2.1.6 Low Voltage Directive (73/23/EEC) including Amendment (93/68/EEC)
2.1.7 Low Voltage Switchgear and Controlgear Assemblies, Part 1: Type Tested and partially type tested Assemblies, IEC 60439 1
2.1.8 Low Voltage Switchgear and Controlgear Assemblies, Part 2: Particular Requirements Busbar Trunking systems (Busway), IEC 60439 2
2.1.9 IEC 61534-1 requirement for Powertrack (PT) system
3 SUBMITTALS
3.1 Product Data: For each type of product indicated. Include data on features, components, ratings, and performance.
Installation, Operation and Maintenance Manual | PIR Series 5VERSION 1
PIR SeriesPRODUCT SPECIFICATION
3.2 Shop Drawings: For Plug-In Raceway include:
3.2.1 Detail equipment assemblies and indicate dimensions, weights, and location and identification of each field connection.
3.2.2 Wiring Connection: For power and monitoring wiring.
3.2.3 Orientation of Plug-In units face in final installation.
3.2.4 Include Plug-In Schedule with detailed description.
3.2.5 Product Data sheets.
3.2.6 Installation Instructions Drawings.
3.3 Manufacturer Certificates: For each product, from manufacturer.
3.4 Operation and Maintenance Data: For Plug-In Raceway System include in operation and maintenance manuals.
4 MAINTENANCE MATERIAL & SPARE PARTS
4.1 Furnish extra materials that match products installed and that are packaged with protective covering for storage and identified with labels describing contents.
4.1.1 Plug-in Units
4.1.2 Field cut kits can be distributed to customize the length of the raceway in the field.
5 QUALITY ASSURANCE
5.1 Manufacturer Qualifications: Firms regularly engaged in the manufacture of raceway systems, boxes and fittings of the types and sizes required, whose products have been in satisfactory use in similar service for not less than 5 years. Provide raceways and boxes produced by a manufacturer listed in this section.
5.2 Electrical Raceways, Boxes, and Components: Comply with requirements of applicable local codes, NEC, UL, ETL, NEMA and IEC Standards pertaining to busway, raceways, boxes, and components. Listed and labeled in accordance with UL857 and NFPA 70, article 100.
6 WARRANTY
6.1 Warranty: The Raceway manufacturer shall guarantee the entire system against defective material and workmanship for a period of one (1) year from date of shipment.
6.2 Manufacturer shall agree to repair or replace components that fail in materials or workmanship within specified warranty period. Warranty shall include all labor, material, and
PIR Series
6 Installation, Operation and Maintenance Manual | PIR Series VERSION 1
PRODUCT SPECIFICATION
related expenses to restore system and/ or components from failures.
7 DELIVERY, STORAGE AND HANDLING
7.1 Deliver raceway system in factory labeled packages.
7.2 Store and handle in strict compliance with manufacture’s written instructions and recommendations.
7.3 Protect from damage due to weather, excessive temperature, and construction operations.
8 ACCEPTABLE MANUFACTURER
8.1 Basis of Specification is Starline Plug-In Raceway as manufactured by Universal Electric Corporation.
8.2 Provide Starline Plug-in Raceway as manufactured by Universal Electric Corporation, 168 Georgetown Rd., Canonsburg, PA 15317: toll-free 1-800-245-6378, telephone 724-597-7800, fax 724-916-2221; www.StarlinePower.com. NO KNOWN EQUAL.
9 STARLINE PLUG-IN RACEWAY
9.1 Starline Plug-In Raceway assembly: Model Series 20A & 60A (domestic), 20A & 63A (international) power only and power and data configurations.
10 PRODUCT DESCRIPTION AND COMPONENTS
10.1 Raceway system that shall be provided as 4 pole, (3Ph plus N) rated up to 480 Vac or 480 Vdc (domestic), 415 Vac (international), in power only single channel or power-data duel channel configurations.
10.2 The 20A and 60A (63A international) continuous surface mounted busway shall use a plug-in type module that allows for the direct plug-in of modules that contain various types of receptacles. Circuit breakers shall be provided as part of the plug-in modules.
10.3 This system is intended for field installation in accordance with Article 368 of the National Electrical Code (NEC) and installation instructions provided by the manufacturer.
10.4 Enclosure: Indoor use only.
10.5 Grounding: Provided by the metal enclosure or by copper ground conductor on request.
10.6 Support: To be supported every 32 inches (813mm) max
10.7 Short Circuit Rating: 10,000 RMS symmetrical amperes.
10.8 System type & Amperage (power only single channel OR power-data duel channel, 20 or 60A/63A)
Installation, Operation and Maintenance Manual | PIR Series 7VERSION 1
PIR SeriesPRODUCT SPECIFICATION
10.8.1 Sections and fittings
10.8.1.1 3 Phase 277/480 Vac or 480 Vdc, 100% rated @ 20 or 60 Amp (domestic)
10.8.1.2 3 Phase 277/480 Vac or 480 Vdc, 100% rated @ 20 or 60 Amp (domestic)
10.8.1.3 3 Phase 415 Vac maximum Power Only @ 20 or 63 Amp (international)
10.8.1.4 3 Phase 415 Vac maximum Power-Data @ 20 or 63 Amp (international)
10.8.2 Conductor Materials
10.8.2.1 20 Amp series uses bare copper; 60 Amp (63 Amp international) series uses tinplated copper wire
x – Raceway length
y - EMI Shield option;
U = Unshielded or
S = Shielded
10.8.3 Joint Kit
10.8.4 End Cap
10.8.5 Elbows
10.8.6 Power End Feeds or Center Feeds
10.8.6.1 Providing components unassembled allows installers to field customize as required. Installer can configure for left hand, right hand, top or rear wire entry points. All units rated at 480 Vac and/or 480 Vdc max / 20 & 60 Amps (domestic); 415 Volts max/ 20 & 63 Amps (international).
10.8.7 Plug-In Module
10.8.7.1 Plug-in modules shall be provided with circuit breaker overcurrent protection at point of use. The circuit breakers and receptacles are factory wired and ordered to meet the user’s power requirements. The raceway covers consist of either plug-in modules or blank cover filler sections.
11 PREPARATION AND INSTALLATION
11.1 Layout drawings of the raceway system should be approved prior to installation. Note: Raceway is intended for indoor applications in well controlled dry environments, it should
PIR Series
8 Installation, Operation and Maintenance Manual | PIR Series VERSION 1
PRODUCT SPECIFICATION
not be installed in wet areas.
11.1.1 Manufacturer’s instructions for installing raceway and fittings should be followed by the installer. All wall surfaces or other permanent structures to which raceway is mounted, should be completed prior to installation.
11.1.1.1 Mechanical Support: Starline Plug-In Raceway should be supported at intervals not exceeding 32 inches (813mm) or in accordance with manufacturer’s installation sheets.
11.1.2 Accessories
11.1.2.1 Provide accessories as required for a complete installation, including insulated bushings and inserts when required by manufacturer.
11.1.3 Unused Openings
11.1.3.1 Close unused Raceway openings using manufacturers’ recommended accessories such as covers, end caps and other such accessories.
12 CLEANING AND PROTECTION
12.1 Clean exposed surfaces using non-abrasive materials and methods recommended by manufacturer.
12.2 Protect raceways and boxes until installation, commissioning and testing.
12.3 Starline Plug-In Raceway is manufactured by Universal Electric Corporation, 168 Georgetown Rd., Canonsburg, PA 15317. Toll-free phone: 1-800-245-6378; telephone: 724-597-7800; fax: 724-916-2221; www.uecorp.com, No known equal.
13 FIELD QUALITY CONTROL
13.1 Installing Contractor Inspections:
13.1.1 Comply with manufacturer's written instructions.
13.1.2 Inspect interiors of enclosures, including the following:
a. Integrity of mechanical and electrical connections.
b. Component type and labeling verification.
c. Ratings of installed components.
13.1.3 Installing Contractor to prepare inspection reports.
Installation, Operation and Maintenance Manual | PIR Series 9VERSION 1
PIR SeriesPRODUCT SELECTION GUIDE
2Section 2Product Selection Guide
PIR Series
10 Installation, Operation and Maintenance Manual | PIR Series VERSION 1
PRODUCT SELECTION GUIDE
| StarlinePower.com
SYSTEM LAYOUT DRAWING
Power Only
2.1
Internal Elbow
Power Feeds
Cover Strip
External Elbow
Vertical Elbow
End Cap
STARLINE Plug-In Raceway is available in standard lengths of 2.5, 5 & 10 feet (1, 2 & 3 meters). Various modules are offered complete with breaker and receptacle, and in both single phase and three phase configurations up to 30 amps.
Wall Mount Clip Installed
(A) (G) (B) (N) (C)
Module
Joint Kit
INTENDED FOR INDOOR USE ONLY
3.3 in. (83.8mm)
20 amp insulator
60 amp insulator
Installation, Operation and Maintenance Manual | PIR Series 11VERSION 1
PIR SeriesPRODUCT SELECTION GUIDE
Power Systems
STRAIGHT SECTIONS
Product DescriptionEach Plug-In Raceway straight section consists of an extruded aluminum backplane with an insulated strip containing copper busbars. The aluminum extrusion acts as a 100% ground path. Each straight section is enclosed by means of cover pieces and plug-in modules (ordered separately). Available as 4-pole (3 phase + Neutral), and 4-pole with isolated ground conductor. Straight sections work with all ampere ratings – 20 and 60 Amp (63 Amp IEC).
Sections should be supported every 32" (813mm) max (typical wall joists are placed every 16" (406mm)). Straight sections are available in standard lengths of 2.5, 5 & 10 feet (1, 2 & 3 meters). If custom lengths are required for your project, Plug-In Raceway is also field cuttable. To learn more, please refer to pages 4.1-4.6.
*Please note, a straight section only includes the backplane of the raceway. Cover pieces must be ordered with their own, separate part number (see pg. 2.10-2.11).
WEIGHT: 1 ft. (.3m): 1 lb/.45 kg
2.2 | StarlinePower.com
Back Plane
Power Cover Piece(ordered separately)
Bus Connector
Available in lengths of 2.5, 5 and 10 feet (1, 2 and 3 meters)
3.3 in. (83.8mm)
Included with Straight Section:
Components for shortening straight:
Installation Guide
Joint Insulator
Joint Kit:
Bus Connector Keeper
PIR Series
12 Installation, Operation and Maintenance Manual | PIR Series VERSION 1
PRODUCT SELECTION GUIDEPower Systems
STRAIGHT SECTIONS: PRODUCT NUMBERS
2.3 | StarlinePower.com
U RP S 020 - 4 H - 0206 1. System
2. ProductLine
7.StraightLength
6.Ground Busbar
5. Poles
1. System (standard of measure)U U.S. M Metric
2. Product Line (section housing)RP Raceway Power
4. Product Frame (maximum amperage)020 20 amps (U.S. & Metric) 060 60 amps (U.S.)
063 63 amps (Metric)
Examples:URPS020-4H-0206 = U.S., Raceway Power, Straight, 20 amps- 4 poles, Housing ground- 2 ft. 6 inches longMRPS063-4G-M300 = Metric, Raceway Power, Straight, 63 amps- 4 poles, Isolated/Dedicated ground- 3 meters long
3. ProductType
4. ProductFrame
3. Product Type (section component)S Straight
5. Poles (number of poles(including neutral))4 4 poles
6. Ground Busbar (type of ground busbar)H Housing Ground G Isolated/Dedicated Ground
7. Straight Length (length of section)*0206 2 ft. 6 in. (U.S.) M100 1 meter (Metric) 0500 5 ft. (U.S.) M200 2 meters (Metric)1000 10 ft. (U.S.) M300 3 meters (Metric)
*If custom lengths are required for your project, Plug-In Raceway is also field cuttable. To learn more, please refer to pages 4.1-4.6.
Installation, Operation and Maintenance Manual | PIR Series 13VERSION 1
PIR SeriesPRODUCT SELECTION GUIDE
Power Systems
ELBOW SECTIONS
Product DescriptionAn elbow is used for making a horizontal or vertical 90 degree change of direction in a raceway run. Specify internal or external for horizontal elbows and up or down for vertical.
Elbows work with all ampere ratings – 20 and 60 Amp (63 Amp IEC); Elbows are 5-pole for use on systems with and without the ground bus. All elbows have a 12 inch x 12 inch (305mm x 305mm) outside foot print and come with (2) bus connector keepers (not pictured) for easy connections to the adjacent sections and 17 inch (432mm) cover pieces. Elbows are designed to be field-cut for jobsite fitting to as-built construction.
To learn more about field cutting, please refer to pages 4.1-4.6.
2.4 | StarlinePower.com
Down TurningVertical Elbow
InternalHorizontal Elbow
Up TurningVertical Elbow
ExternalHorizontal Elbow
Polarization Stripe
Polarization StripePolarization Stripe
Polarization Stripe
12 in. (305mm)
12 in. (305mm)
PIR Series
14 Installation, Operation and Maintenance Manual | PIR Series VERSION 1
PRODUCT SELECTION GUIDEPower Systems
ELBOW SECTIONS: PRODUCT NUMBERS
2.5 | StarlinePower.com
U RP E 020 - 4 H - 2 - SIL - IN 1. System
2. ProductLine
8.Paint Color
6.Ground Busbar
5. Poles
1. System (standard of measure)U U.S. M Metric
2. Product Line (section housing)RP Raceway Power
4. Product Frame (maximum amperage)020 20 amps (U.S. & Metric) 060 60 amps (U.S.)
063 63 amps (Metric)
8. Paint (color of cover)SIL Paint UEC Silver BLK Paint UEC BlackWHT Paint UEC White
Examples:URPE020-4H-2-SIL-UP = U.S., Raceway Power, Elbow, 20 amps- 4 poles, Housing ground- 2 inches (50.8mm) tall- painted Silver- Up turning vertical elbowMRPE063-4G-3-BLK-IN = Metric, Raceway Power, Elbow, 63 amps- 4 poles, Isolated/Dedicated ground- 3 inches (76.2mm) tall- painted Black- Internal horizontal elbow
3. ProductType
4. ProductFrame
3. Product Type (section component)E Elbow
5. Poles (number of poles(including neutral))4 4 poles
6. Ground Busbar (type of ground busbar)H Housing Ground G Isolated/Dedicated Ground
9.Turning Direction
9. Turning Direction (direction of elbow)IN Internal Horizontal EX External Horizontal
UP Up turning vertical DN Down turning vertical
*RAL system can also be used; reference page 8.1
*
7.Height
7. Height (height of system cover)2 2 inches (50.8mm) 3 3 inches (76.2mm)
Installation, Operation and Maintenance Manual | PIR Series 15VERSION 1
PIR SeriesPRODUCT SELECTION GUIDE
Power Systems
UNIVERSAL END FEED KITProduct DescriptionProvide an inconspicuous and fully customizable means for connecting power to the raceway busbars at the end of a run. Kit consists of a 12 in. (305mm) section of raceway, connector, wire leads, and end cap.
Providing components unassembled allows installers to field customize as required.
*Installer can configure for left hand, right hand, top or rear wire entry points- thus the term 'Universal'. End feeds work with all ampere ratings – 20 and 60 Amp (63 Amp IEC).
If current monitoring is required, it must be ordered separately and at the same time as the Universal End Feed Kit. Please see pages 7.1 - 7.2 for metering options.
*Please note: cover piece will be 17 inches (432mm) long, with 5 inches (127mm) hanging over one side of the 12 inch (305mm) back plane.
WEIGHT: 2.25 lbs/1 kg
2.6 | StarlinePower.com
12 in. (305mm) Back plane
End cap
Bus connector keeper
Bus connector
17 in. (432mm) Cover piece
Ground wire
PIR Series
16 Installation, Operation and Maintenance Manual | PIR Series VERSION 1
PRODUCT SELECTION GUIDEPower Systems
UNIVERSAL END FEED: PRODUCT NUMBERS
2.7 | StarlinePower.com
U RP F 020 - 4 H - 2 - SIL 1. System
2. ProductLine
8.Paint Color
6.Ground Busbar
5. Poles
1. System (standard of measure)U U.S. M Metric
2. Product Line (section housing)RP Raceway Power
4. Product Frame (maximum amperage)020 20 amps (U.S. & Metric) 060 60 amps (U.S.)
063 63 amps (Metric)
8. Paint (color of cover)SIL Paint UEC Silver BLK Paint UEC BlackWHT Paint UEC White
Examples:URPF060-4G-2-SIL = U.S., Raceway Power, End Feed, 60 amps- 4 poles, Isolated/Dedicated ground- 2 inches (50.8mm) tall-painted SilverMRPF063-4H-2-PK6 = Metric, Raceway Power, End Feed, 63 amps- 4 poles, Housing ground- 2 inches (50.8mm) tall-painted RAL 6006
3. ProductType
4. ProductFrame
3. Product Type (section component)F End Feed
5. Poles (number of poles(including neutral))4 4 poles
6. Ground Busbar (type of ground busbar)H Housing Ground G Isolated/Dedicated Ground
*
*RAL system can also be used; reference page 8.1
7. Height (height of system cover)2 2 inches (50.8mm) 3 3 inches (76.2mm)
7.Height
Installation, Operation and Maintenance Manual | PIR Series 17VERSION 1
PIR SeriesPRODUCT SELECTION GUIDE
Power Systems
UNIVERSAL CENTER FEED KITProduct DescriptionProvides an inconspicuous means for connecting power to the raceway busbars in the center of a run. Kit consists of a 12 in. (305mm) section of raceway, connector and wire leads.
Providing components unassembled allows installers to field customize as required.
*Installer can configure for top, bottom or rear wire entry points- thus the term 'Universal'. Center feeds work with all ampere ratings – 20 and 60 Amp (63 Amp IEC).
*Please note: cover piece will be 22 inches (559mm) long, with 5 inches (127mm) hanging over each side of the 12 inch (305mm) back plane.
WEIGHT: 2.25 lbs/1 kg
2.8 | StarlinePower.com
12 in. (305mm) Back plane
Bus connector keeper
Bus connector keeper
22 in. (559mm) Cover piece
Bus connector
Bus connector
Ground wire
Current Monitoring with P13 Module:
If a current monitoring module is required, it must be located immediately to the right of a Center Feed when the polarizing stripe is on the bottom.
= polarizing stripe
Center Feed
P13 module with M50 meter
See pages 7.1-7.2 for current monitoring options.
PIR Series
18 Installation, Operation and Maintenance Manual | PIR Series VERSION 1
PRODUCT SELECTION GUIDEPower Systems
UNIVERSAL CENTER FEED: PRODUCT NUMBERS
2.9 | StarlinePower.com
U RP C 020 - 4 H - 2 - SIL 1. System
2. ProductLine
8.Paint Color
6.Ground Busbar
5. Poles
1. System (standard of measure)U U.S. M Metric
2. Product Line (section housing)RP Raceway Power
4. Product Frame (maximum amperage)020 20 amps (U.S. & Metric) 060 60 amps (U.S.)
063 63 amps (Metric)
8. Paint (color of cover)SIL Paint UEC Silver BLK Paint UEC BlackWHT Paint UEC White
Examples:URPC060-4G-2-SIL = U.S., Raceway Power, Center Feed, 60 amps- 4 poles, Isolated/Dedicated ground- 2 inches (50.8mm) tall- painted SilverMRPC063-4H-3-WHT = Metric, Raceway Power, Center Feed, 63 amps- 4 poles, Housing ground- 3 inches (76.2mm) tall- painted White
3. ProductType
4. ProductFrame
3. Product Type (section component)C Center Feed
5. Poles (number of poles(including neutral))4 4 poles
6. Ground Busbar (type of ground busbar)H Housing Ground G Isolated/Dedicated Ground
*
*RAL system can also be used; reference page 8.1
7. Height (height of system cover)2 2 inches (50.8mm) 3 3 inches (76.2mm)
7.Height
Installation, Operation and Maintenance Manual | PIR Series 19VERSION 1
PIR SeriesPRODUCT SELECTION GUIDE
Product DescriptionCover pieces are required to cover the remaining open areas that are not covered by Plug-In Modules, Feeds or Elbows. Going along with your straight pieces of Power Raceway or Power & Data Raceway, you will need to order your power cover pieces, or your power and your data cover pieces.
WEIGHT: .55 lb/.25 kg per 10 inches (254mm)
2.10 | StarlinePower.com
Power Cover Piece
3.3 in. (83.8mm)
Power Systems
POWER COVER PIECES
PIR Series
20 Installation, Operation and Maintenance Manual | PIR Series VERSION 1
PRODUCT SELECTION GUIDE
U PC - 0010 -
2 - SIL
Power Systems
POWER COVER PIECES: PRODUCT NUMBERS
2.11 | StarlinePower.com
1. System (standard of measure)U U.S. M Metric
2. Product (section housing)PC Power Cover
5. Paint Color (allows painting of the housing)SIL Paint UEC Silver BLK Paint UEC Black
WHT Paint UEC White
5. Paint Color
3.Length
2. Product
1. System
Examples:UPC-0500-2-SIL = U.S., Power Cover- 5 feet- 2 inches (50.8mm) tall- painted SilverMPC-M200-2-BLK = Metric, Power Cover- 2 meters- 2 inches (50.8mm) tall- painted Black
3. Length (length of section)0010 0 ft. 10 in. (U.S.) 0015 0 ft. 15 in. (U.S.) 0206 2 ft. 6 in. (U.S.) 0500 5 ft. (U.S.)
*
*RAL system can also be used; reference page 8.1M025 25 centimeters (Metric) M200 2 meters (Metric)
4. Height (height of system cover)2 2 inches (50.8mm) 3 3 inches (76.2mm)
4. Height
Installation, Operation and Maintenance Manual | PIR Series 21VERSION 1
PIR SeriesPRODUCT SELECTION GUIDE
Power Systems
ASSEMBLY ACCESSORIES: SYSTEM HARDWARE
2.12 | StarlinePower.com
10 in. (254mm)Power Cover included
Bus connector keeper
Bus connector
Joint KitA joint kit makes electrical and mechanical connections between raceway sections. Consists of a bus connector, bus connector keeper and a 10 inch (254mm) piece of blank cover to enclose the joint.
The bus connector presses and locks into place between adjoining sections. The bus connector keeper is positioned then screwed to the backplane, making the mechanical and equipment ground connections.
Joint kits are 5-pole for use on systems with and without the ground bus.
The two options for a joint kit include cover height (represented by a 2 or 3 for 2 inches or 3 inches) and color (silver, black, white or RAL).
Part NumberSRPJK-PIR-2-SILSRPJK-PIR-2-BLKSRPJK-PIR-2-WHTSRPJK-PIR-3-SILSRPJK-PIR-3-BLKSRPJK-PIR-3-WHT
*RAL color codes can also be used
End Cap KitUsed for covering and securing open ends of the raceway. The end cap, screws, five red safety covers and 17 inches (432mm) of power cover is included for a standard straight.
For straights that will be field cut, two end caps, screws and an end cap clip are provided.
The two options for an end cap kit include cover height (represented by a 2 or 3 for 2 inches or 3 inches) and color (silver, black, white or RAL).
Part NumberSRPEC-PIR-2-SILSRPEC-PIR-2-BLKSRPEC-PIR-2-WHTSRPEC-PIR-3-SILSRPEC-PIR-3-BLKSRPEC-PIR-3-WHT
*RAL color codes can also be used
17 in. (432mm)Power Cover included
To be used with standard straights
To be used when field cutting straights to end a run
**A joint kit is provided with each straight section (see pg. 2.2)
**Kit contains parts for ending both standard and field cut straights
PIR Series
22 Installation, Operation and Maintenance Manual | PIR Series VERSION 1
PRODUCT SELECTION GUIDEPower Systems
ASSEMBLY ACCESSORIES: SUPPORT HARDWARE
Wall Mount ClipSections of Plug-In Raceway may be mounted by means of wall mount clips. Use of the wall mount clips can dramatically speed up the system installation time compared to direct wall mounting.
The clip is installed by inserting two flat head screws through the clip and into the support point on the wall. The Plug-In Raceway pivots into the hook and is secured with a set screw. One wall mount clip is required every 30 inches (76 cm).
*Plug-In Raceway can also be installed by inserting screws through the backplane and directly into wall studs.
2.13 | StarlinePower.com
Wall Mount Clip Installed
Part NumberSRPWMC-PIR
Installation, Operation and Maintenance Manual | PIR Series 23VERSION 1
PIR SeriesPRODUCT SELECTION GUIDE
Power Systems
ADD-ON ACCESSORIES: ANGLED COVER
Angled CoverThe Angled Cover is perfect for clean rooms and any other environment where it's critical that dust does not build up. Angled Covers can be purchased with both Power only and Power & Data systems.
The Angled Cover comes with included brackets that are screwed into joists along the wall above the raceway. The Angled Cover then snaps onto the brackets.
The Angled Cover can be cut to size in the field and easily reconfigured to match any layout.
Each order of 5 ft. (2 meters) of Angled Cover comes with 2 brackets (18"[457mm] each) and an end cap.
Each order of 10 ft. (3 meters) of Angled Cover comes with 3 brackets (18"[457mm] each) and an end cap.
End caps can also be ordered separately, using the following product numbers:
SACEC-45-PIR-SILSACEC-45-PIR-BLKSACEC-45-PIR-WHT
2.14 | StarlinePower.com
Angled Cover
U AC - 45 - 0010
- SIL
1. System (standard of measure)U U.S. M Metric
2. Product (section housing)AC Angled Cover
4. Length (length of section)0500 5 ft. (U.S.) 1000 10 ft. (U.S.)
M200 2 meters (Metric)M300 3 meters (Metric)
5. Paint Color (allows painting of the housing)SIL Paint UEC Silver BLK Paint UEC Black
WHT Paint UEC White
1. System
2. Product
4. Length
5. Paint Color
Examples:UAC-45-0500-SIL = U.S., Angled Cover- 45 degree angle- 5 feet- painted SilverMAC-45-M300-BLK = Metric, Angled Cover- 45 degree angle- 3 meters- painted Black
Bracket
3. Angle
3. Angle (angle of cover)45 45 degree angle
End Cap
PIR Series
24 Installation, Operation and Maintenance Manual | PIR Series VERSION 1
PRODUCT SELECTION GUIDE
| StarlinePower.com
SYSTEM LAYOUT DRAWING
Power & Data
3.1
Internal ElbowData Cover (w/ cut out)
Power Feeds
Cover Strip
External Elbow
Vertical Elbow
End Cap
STARLINE Plug-In Raceway is available in standard lengths of 2.5, 5 & 10 feet (1, 2 & 3 meters). Various modules are offered complete with breaker and receptacle, and in both single phase and three phase configurations up to 30 amps.
Module
Joint Kit
INTENDED FOR INDOOR USE ONLY
Installation, Operation and Maintenance Manual | PIR Series 25VERSION 1
PIR SeriesPRODUCT SELECTION GUIDE
Power & Data Systems
STRAIGHT SECTIONS
Product DescriptionEach Plug-In Raceway straight section consists of a two-channel extruded aluminum housing. The power channel contains an insulated strip with copper busbars. The aluminum extrusion acts as a 100% ground path. The data channel provides a raceway for datacom cabling.
Each raceway straight is enclosed by means of cover pieces and plug-in modules (ordered separately). Power available as 4 pole (3 phase + Neutral) and 4 pole with isolated ground conductor. Straight sections work with all ampere ratings – 20 and 60 Amp (63 Amp IEC).
Sections should be supported every 32" (813mm) max (typical wall joists are placed every 16" (406mm)). STARLINE Plug-In Raceway is available in standard lengths of 2.5, 5 & 10 feet (1, 2 & 3 meters). If custom lengths are required for your project, Plug-In Raceway is also field cuttable. To learn more, please refer to pages 4.1-4.6.
*Please note, a straight section only includes the backplane of the raceway. Cover strip pieces must be ordered with their own, separate part number (see pg. 3.10-3.13).
WEIGHT: 1.5 lb/.68 kg per foot
3.2 | StarlinePower.com
Back Plane
Data Side
Power Side
Bus Connector
Bus Connector Keeper
*Power and Data Cover Pieces ordered
separately (see pgs. 3.10-3.13)
Available in lengths of 2.5, 5 and 10 feet (1, 2 and 3 meters)
6 in. (152.4mm)
Now Included with Straight:
Components for resizing straight:
Installation Guide
Joint Insulator
Joint Kit:
Power & Data Covers
PIR Series
26 Installation, Operation and Maintenance Manual | PIR Series VERSION 1
PRODUCT SELECTION GUIDEPower & Data Systems
STRAIGHT SECTIONS: PRODUCT NUMBERS
3.3 | StarlinePower.com
U RD S 020 - 4 H - 0206 U 1. System
2. ProductLine
7.StraightLength
6.Ground Busbar
5. Poles
1. System (standard of measure)U U.S. M Metric
2. Product Line (section housing)RD Raceway Dual
4. Product Frame (maximum amperage)020 20 amps (U.S. & Metric) 060 60 amps (U.S.)
063 63 amps (Metric)
Examples:URDS020-4H-0500U = U.S., Raceway Dual, Straight, 20 amps- 4 poles, Housing ground- 5 feet long, unshieldedMRDS063-4G-M100S = Metric, Raceway Dual, Straight, 63 amps- 4 poles, Isolated/Dedicated ground- 1 meter long, shielded
3. ProductType
4. ProductFrame
3. Product Type (section component)S Straight
5. Poles (number of poles(including neutral))4 4 poles
6. Ground Busbar (type of ground busbar)H Housing Ground G Isolated/Dedicated Ground
8.EMI Shield
8. EMI Shield (optional shield to minimize electromagnetic radiation)U Unshielded S Shielded
7. Straight Length (length of section)*0206 2 ft. 6 in. (U.S.) M100 1 meter (Metric) 0500 5 ft. (U.S.) M200 2 meters (Metric)1000 10 ft. (U.S.) M300 3 meters (Metric)
*If custom lengths are required for your project, Plug-In Raceway is also field cuttable. To learn more, please refer to pages 4.1 - 4.6.
EMI Shield (optional)
(A) (G) (B) (N) (C)
Installation, Operation and Maintenance Manual | PIR Series 27VERSION 1
PIR SeriesPRODUCT SELECTION GUIDE
Power & Data Systems
ELBOW SECTIONS
Product DescriptionAn elbow is used for making a horizontal or vertical 90 degree change of direction in a raceway run. Specify internal or external for horizontal elbows and up or down for vertical.
Elbows work with all ampere ratings – 20 and 60 Amp (63 Amp IEC); Elbows are 5-pole for use on systems with and without the ground bus. All elbows have a 12 inch x 12 inch (305mm x 305mm) outside foot print and come with (2) bus connector keepers (not pictured) for easy connections to the adjacent sections and 17 inch (432mm) cover pieces. Elbows are designed to be field-cut for jobsite fitting to as-built construction.
To learn more about field cutting, please refer to pages 4.1 - 4.6.
3.4 | StarlinePower.com
Down TurningVertical Elbow
InternalHorizontal Elbow
Up TurningVertical Elbow
ExternalHorizontal Elbow
Polarization Stripe
Polarization Stripe Polarization Stripe
Polarization Stripe
12 in. (305mm)
12 in. (305mm)
PIR Series
28 Installation, Operation and Maintenance Manual | PIR Series VERSION 1
PRODUCT SELECTION GUIDEPower & Data Systems
ELBOW SECTIONS: PRODUCT NUMBERS
3.5 | StarlinePower.com
U RD E 020 - 4 H - 2 - SIL - IN U 1. System
2. ProductLine
8.Paint Color
6.Ground Busbar
5. Poles
1. System (standard of measure)U U.S. M Metric
2. Product Line (section housing)RD Raceway Dual
4. Product Frame (maximum amperage)020 20 amps (U.S. & Metric) 060 60 amps (U.S.)
063 63 amps (Metric)
8. Paint (color of cover)SIL Paint UEC Silver BLK Paint UEC BlackWHT Paint UEC White
Examples:URDE060-4H-2-SIL-UPU = U.S., Raceway Dual, Elbow, 60 amps- 4 poles, Housing ground- 2 inches (50.8mm) tall- painted Silver- Up turning vertical elbow, UnshieldedMRDE063-4G-2-BLK-INS = Metric, Raceway Dual, Elbow, 63 amps- 4 poles, Isolated/Dedicated ground-2 inches (50.8mm) tall- painted Black- Internal horizontal elbow, Shielded
3. ProductType
4. ProductFrame
3. Product Type (section component)E Elbow
5. Poles (number of poles(including neutral))4 4 poles
6. Ground Busbar (type of ground busbar)H Housing Ground G Isolated/Dedicated Ground
9.Turning Direction
9. Turning Direction (direction of elbow)IN Internal Horizontal EX External Horizontal
UP Up turning vertical DN Down turning vertical
10. EMI Shield (optional shield to minimize electromagnetic radiation)U Unshielded S Shielded
10.EMI Shield
*
*RAL system can also be used; reference page 8.1
7. Height (height of system cover)2 2 inches (50.8mm) 3 3 inches (76.2mm)
7.Height
Installation, Operation and Maintenance Manual | PIR Series 29VERSION 1
PIR SeriesPRODUCT SELECTION GUIDE
Power & Data Systems
UNIVERSAL END FEED KITProduct DescriptionProvide an inconspicuous and fully customizable means for connecting power to the raceway busbars at the end of a run. Kit consists of a 12 in. (305mm) section of raceway, connector, wire leads, and end cap.
Providing components unassembled allows installers to field customize as required.
*Installer can configure for left hand, right hand, top or rear wire entry points- thus the term 'Universal'. End feeds work with all ampere ratings – 20 and 60 Amp (63 Amp IEC).
If current monitoring is required, it must be ordered separately and at the same time as the Universal End Feed Kit. Please see pages 7.1 - 7.2 for metering options.
*Please note: cover piece will be 17 inches (432mm) long, with 5 inches (127mm) hanging over one side of the 12 inch (305mm) back plane. WEIGHT: 2.7 lbs/1.2 kg
3.6 | StarlinePower.com
12 in (305mm) Back plane
End cap
17 in (432mm) Back plane
Bus connector keeper
Bus connector
Ground wire
PIR Series
30 Installation, Operation and Maintenance Manual | PIR Series VERSION 1
PRODUCT SELECTION GUIDEPower & Data Systems
UNIVERSAL END FEED: PRODUCT NUMBERS
3.7 | StarlinePower.com
U RD F 020 - 4 H - 2 - SIL - U 1. System
2. ProductLine
8.Paint Color
6.Ground Busbar
5. Poles
1. System (standard of measure)U U.S. M Metric
2. Product Line (section housing)RD Raceway Dual
4. Product Frame (maximum amperage)020 20 amps (U.S. & Metric) 060 60 amps (U.S.)
063 63 amps (Metric)
8. Paint (color of the cover)SIL Paint UEC Silver BLK Paint UEC BlackWHT Paint UEC White
Examples:URDF060-4G-2-SIL-S = U.S., Raceway Dual, End Feed, 60 amps- 4 poles, Isolated/Dedicated ground-2 inches (50.8mm) tall- painted Silver- ShieldedMRDF063-4H-3-PB8-U = Metric, Raceway Dual, End Feed, 63 amps- 4 poles, Housing ground-3 inches (76.2mm) tall- painted RAL 3018- Unshielded
3. ProductType
4. ProductFrame
3. Product Type (section component)F End Feed
5. Poles (number of poles(including neutral))4 4 poles
6. Ground Busbar (type of ground busbar)H Housing Ground G Isolated/Dedicated Ground
9. EMI Shield (optional shield to minimize electromagnetic radiation)U Unshielded S Shielded
9.EMI Shield
*RAL system can also be used; reference page 8.1
*
7. Height (height of system cover)2 2 inches (50.8mm) 3 3 inches (76.2mm)
7.Height
Installation, Operation and Maintenance Manual | PIR Series 31VERSION 1
PIR SeriesPRODUCT SELECTION GUIDE
Power & Data Systems
UNIVERSAL CENTER FEED KITProduct DescriptionProvides an inconspicuous means for connecting power to the raceway busbars in the center of a run. Kit consists of a 12 inch (305mm) section of raceway, connector and wire leads.
Providing components unassembled allows installers to field customize as required.
*Installer can configure for top, bottom or rear wire entry points- thus the term 'Universal'. Center feeds work with all ampere ratings – 20 and 60 Amp (63 Amp IEC).
*Please note: cover piece will be 22 inches (559mm) long, with 5 inches (127mm) hanging over each side of the 12 inch (305mm) back plane.
WEIGHT: 2.7 lbs/1.2 kg
3.8 | StarlinePower.com
Back plane
Bus connector keeper
Bus connector keeper
Bus connectorBus connector
12 in (305mm) back plane
22 in (559mm) cover piece
Ground wire
Current Monitoring with P13 Module:
If a current monitoring module is required, it must be located immediately to the right of a Center Feed when the polarizing stripe is on the bottom.
= polarizing stripe
See pages 7.1-7.2 for current monitoring options.
Center Feed
P13 module with M50 meter
PIR Series
32 Installation, Operation and Maintenance Manual | PIR Series VERSION 1
PRODUCT SELECTION GUIDEPower & Data Systems
UNIVERSAL CENTER FEED: PRODUCT NUMBERS
3.9 | StarlinePower.com
U RD C 020 - 4 H - 2 - SIL - U 1. System
2. ProductLine
8.Paint Color
6.Ground Busbar
5. Poles
1. System (standard of measure)U U.S. M Metric
2. Product Line (section housing)RD Raceway Dual
4. Product Frame (maximum amperage)020 20 amps (U.S. & Metric) 060 60 amps (U.S.)
063 63 amps (Metric)
8. Paint (color of the cover)SIL Paint UEC Silver BLK Paint UEC BlackWHT Paint UEC White
Examples:URDC060-4G-3-SIL-U = U.S., Raceway Dual, Center Feed, 60 amps- 4 poles, Isolated/Dedicated ground- 3 inches (76.2mm) tall- painted Silver, UnshieldedMRDC063-4H-2-WHT-U = Metric, Raceway Power, Center Feed, 63 amps- 4 poles, Housing ground- 2 inches (50.8mm) tall- painted White, Unshielded
3. ProductType
4. ProductFrame
3. Product Type (section component)C Center Feed
5. Poles (number of poles(including neutral))4 4 poles
6. Ground Busbar (type of ground busbar)H Housing Ground G Isolated/Dedicated Ground
9.EMI Shield
9. EMI Shield (optional shield to minimize electromagnetic radiation)U Unshielded S Shielded
*
*RAL system can also be used; reference page 8.1
7. Height (height of system cover)2 2 inches (50.8mm) 3 3 inches (76.2mm)
7.Height
Installation, Operation and Maintenance Manual | PIR Series 33VERSION 1
PIR SeriesPRODUCT SELECTION GUIDE
Cover Pieces
POWER COVER PIECES
Product DescriptionCover pieces are required to cover the remaining open areas that are not covered by Plug-In Modules, Feeds or Elbows. Going along with your straight pieces of Power Raceway or Power & Data Raceway, you will need to order your power cover pieces, or your power and your data cover pieces.
WEIGHT: .55 lb/.25 kg per 10 inches (254mm)
3.10 | StarlinePower.com
Power Cover Piece
3.3 in. (83.8mm)
PIR Series
34 Installation, Operation and Maintenance Manual | PIR Series VERSION 1
PRODUCT SELECTION GUIDE
U PC - 0010 -
2 - SIL
Power Cover Pieces
POWER COVER PIECES: PRODUCT NUMBERS
3.11 | StarlinePower.com
1. System (standard of measure)U U.S. M Metric
2. Product (section housing)PC Power Cover
5. Paint Color (allows painting of the housing)SIL Paint UEC Silver BLK Paint UEC Black
WHT Paint UEC White
5. Paint Color
3.Length
2. Product
1. System
Examples:UPC-0500-2-SIL = U.S., Power Cover- 5 feet- 2 inches (50.8mm) tall- painted SilverMPC-M200-2-BLK = Metric, Power Cover- 2 meters- 2 inches (50.8mm) tall- painted Black
3. Length (length of section)0010 0 ft. 10 in. (U.S.) 0015 0 ft. 15 in. (U.S.) 0206 2 ft. 6 in. (U.S.) 0500 5 ft. (U.S.)
*
*RAL system can also be used; reference page 8.1M025 25 centimeters (Metric) M200 2 meters (Metric)
4. Height (height of system cover)2 2 inches (50.8mm) 3 3 inches (76.2mm)
4. Height
Installation, Operation and Maintenance Manual | PIR Series 35VERSION 1
PIR SeriesPRODUCT SELECTION GUIDE
Cover Pieces
DATA COVER PIECES
Product DescriptionCover pieces for data outlets are provided with a rectangular cutout sized for the targetcommunication device. There are two cutouts available the C1 and C2. The “C1 cutout”measures 2.64”x1.320” (67.056 x 33.528mm) with mounting hole spacing of 3.28” (83.312mm). The C1 cutout is able to accept two and three port housings.
The C2 cutout is designed to accept angled modules, making it possible to meet bend radius requirements while maintainingthe sleek design of the raceway. The C2 Cutout is designed to accept HUBBELL® and BLACK BOX® Modules or othermanufacturer equivalent.
The modules and housings accept a wide variety of Data, Audio/Video, and Fiber Jacks.
WEIGHT (no cutout): .4 lb/.18 kg per 10 inches (254mm)
3.12 | StarlinePower.com
Data Cover Piece with C2 Cutout
Data Cover Piece with C1 Cutout
Data Cover Piece with no cutout
C1 cutout with 2 ISF3W device configurations
C1 cutout with 1 ISF2BK device configuration
C1 cutout with 1 ISF2GY device configuration
C1 cutout with 1 ISF3GY device configuration
C2 cutout with IM2IA15GY device configuration
C2 cutout with IM2IA15W device configuration
Cutout Configuration DescriptionC1 ISF3B 3-port frame
C1 IM1IA15GY 1-port recessed angle, gray
C1 (2) SF3W (2) 3-port frame, white
C1 ISF2BK 2-port frame, black
C1 ISF2W 2-port frame, white
C1 ISF3GY outlet cover, 3-port frame, gray
C1 ISF2GY outlet cover, 2-port frame, gray
C1 ISF3W outlet cover, 3-port frame, white
C2 IM1IA15W outlet cover, white
C2 IM2IA15W 2-port recessed angled, white
C2 IM2KA15GY 2-port angled, gray
PIR Series
36 Installation, Operation and Maintenance Manual | PIR Series VERSION 1
PRODUCT SELECTION GUIDE
U DC - 0010
- SIL
Data Cover Pieces
BLANK DATA COVER PIECES: PRODUCT NUMBERS
3.13 | StarlinePower.com
U DC - C1 - 0010 - 1 - ISF3B
- SIL
6. Device
7. Paint Color
2. Product (section housing)DC Data Cover
Examples:UDC-C1-0010-2-IM1IA15GY-SIL = U.S., Data Cover- C1 cut out- 10 inches, 2 devices- IM1IA15GY configuration- painted SilverMDC-C2-M025-1-IM2IA12W-BLK = Metric, Data Cover- C2 cut out- 25 centimeters, 1 device- IM2IA12W configuration- painted Black
1. System
2. Product
3. Cut out
4.Length
5. Quantity
1. System (standard of measure)U U.S. M Metric
3. Cut out (cut-out size)C1 C1 C2 C2
5. Quantity (number of devices)1 1 device 2 2 devices
6. Device (NEMA or IEC configuration)*For a complete list of NEMA & IEC configurations, see pg. 8.1
7. Paint Color (allows painting of the housing)SIL Paint UEC Silver BLK Paint UEC Black
WHT Paint UEC White
CUT-OUT DATA COVER PIECES: PRODUCT NUMBERS
1. System (standard of measure)U U.S. M Metric
2. Product (section housing)DC Data Cover
4. Paint Color (allows painting of the housing)SIL Paint UEC Silver BLK Paint UEC Black
WHT Paint UEC White
4. Paint Color
3.Length
2. Product
1. System
Examples:UDC-0206-SIL = U.S., Data Cover- 2 feet 6 inches- painted SilverMDC-M025-BLK = Metric, Data Cover- 25 centimeters- painted Black
4. Length (length of section)0010 0 ft. 10 in. (U.S.) M025 25 centimeters (Metric)
3. Length (length of section)0010 0 ft. 10 in. (U.S.) 0015 0 ft. 15 in. (U.S.) 0206 2 ft. 6 in. (U.S.) 0500 5 ft. (U.S.)
*
*
*RAL system can also be used; reference page 8.1
*RAL system can also be used; reference page 8.1
M025 25 centimeters (Metric) M200 2 meters (Metric)
Installation, Operation and Maintenance Manual | PIR Series 37VERSION 1
PIR SeriesPRODUCT SELECTION GUIDE
Power & Data Systems
ASSEMBLY ACCESSORIES: SYSTEM HARDWARE
3.14 | StarlinePower.com
10 in. (254mm)Power Cover included
Bus connector keeper
Bus connector
Joint KitA joint kit makes electrical and mechanical connections between raceway sections. Consists of a bus connector, bus connector keeper and a 10 inch (254mm) piece of blank cover to enclose the joint.
The bus connector presses and locks into place between adjoining sections. The bus connector keeper is positioned then screwed to the backplane, making the mechanical and equipment ground connections. Joint kits are 5-pole for use on systems with and without the ground bus.
The two options for a joint kit include cover height (represented by a 2 for 2 inches or 3 for 3 inches) and color (silver, black, white or RAL). *Please note: Even if 3 is selected, the data channel cover will always remain at 2 inches (50.8mm) tall.
Part NumberSRDJK-PIR-2-SILSRDJK-PIR-2-BLKSRDJK-PIR-2-WHTSRDJK-PIR-3-SILSRDJK-PIR-3-BLKSRDJK-PIR-3-WHT
*RAL color codes can also be used
End Cap KitUsed for covering and securing open ends of the raceway. The end cap, screws, five red safety covers and 17 inches (432mm) of power and data cover is included for a standard straight.
For straights that will be field cut, two end caps, screws and an end cap clip are provided.
The two options for a joint kit include cover height (represented by a 2 for 2 inches or 3 for 3 inches) and color (silver, black, white or RAL). *Please note: Even if 3 is selected, the data channel cover will always remain at 2 inches (50.8mm) tall.
Part NumberSRDEC-PIR-2-SILSRDEC-PIR-2-BLKSRDEC-PIR-2-WHTSRDEC-PIR-3-SILSRDEC-PIR-3-BLKSRDEC-PIR-3-WHT
*RAL color codes can also be used
17 in. (432mm)Power & Data Cover
included
To be used with standard straights
To be used when field cutting straights to end a run
**A joint kit is provided with each straight section (see pg. 3.2)
**Kit contains parts for ending both standard and field cut straights
PIR Series
38 Installation, Operation and Maintenance Manual | PIR Series VERSION 1
PRODUCT SELECTION GUIDEPower & Data Systems
ASSEMBLY ACCESSORIES: SUPPORT HARDWARE
Wall Mount ClipSections of Plug-In Raceway may be mounted by means of wall mount clips. Use of the wall mount clips can dramatically speed up the system installation time compared to direct wall mounting.
The clip is installed by inserting two flat head screws through the clip and into the support point on the wall. The Plug-In Raceway pivots into the hook and is secured with a set screw. One wall mount clip is required every 30 inches (76 cm).
*Plug-In Raceway can also be installed by inserting screws through the backplane and directly into wall studs.
3.15 | StarlinePower.com
Wall Mount Clip Installed
Part NumberSRDWMC-PIR
Installation, Operation and Maintenance Manual | PIR Series 39VERSION 1
PIR SeriesPRODUCT SELECTION GUIDE
Power & Data Systems
ADD-ON ACCESSORIES: ANGLED COVER
Angled CoverThe Angled Cover is perfect for clean rooms and any other environment where it's critical that dust does not build up. Angled Covers can be purchased with both Power only and Power & Data systems.
The Angled Cover comes with included brackets that are screwed into joists along the wall above the raceway. The Angled Cover then snaps onto the brackets.
The Angled Cover can be cut to size in the field and easily reconfigured to match any layout.
Each order of 5 ft. (2 meters) of Angled Cover comes with 2 brackets (18"[457mm] each) and an end cap.
Each order of 10 ft. (3 meters) of Angled Cover comes with 3 brackets (18"[457mm] each) and an end cap.
End caps can also be ordered separately, using the following product numbers:
SACEC-45-PIR-SILSACEC-45-PIR-BLKSACEC-45-PIR-WHT
3.16 | StarlinePower.com
Angled Cover
U AC - 45 - 0010
- SIL
1. System (standard of measure)U U.S. M Metric
2. Product (section housing)AC Angled Cover
4. Length (length of section)0500 5 ft. (U.S.) 1000 10 ft. (U.S.)
M200 2 meters (Metric)M300 3 meters (Metric)
5. Paint Color (allows painting of the housing)SIL Paint UEC Silver BLK Paint UEC Black
WHT Paint UEC White
1. System
2. Product
4. Length
5. Paint Color
Examples:UAC-45-0500-SIL = U.S., Angled Cover- 45 degree angle- 5 feet- painted SilverMAC-45-M300-BLK = Metric, Angled Cover- 45 degree angle- 3 meters- painted Black
Bracket
3. Angle
3. Angle (angle of cover)45 45 degree angle
End Cap
PIR Series
40 Installation, Operation and Maintenance Manual | PIR Series VERSION 1
PRODUCT SELECTION GUIDE
| StarlinePower.com
SYSTEM LAYOUT DRAWING
Cabinet Busway Series
6.1
The Starline Plug-In Raceway Cabinet Busway (CB) series is available in multiple lengths with various cord lengths and connector body options. Plug-in modules are offered complete with breaker and receptacle, and in both single phase and three phase configurations up to 30 amps. System and modules are ordered separately.
Plug-In Modules
INTENDED FOR INDOOR USE ONLY
3.3 in. (83.8mm)
60 amp insulator
(A) (G) (B) (N) (C)
Plug-In Modules
CB System
Installation, Operation and Maintenance Manual | PIR Series 41VERSION 1
PIR SeriesPRODUCT SELECTION GUIDE
Cabinet Busway Series
SYSTEM COMPONENTS
Product DescriptionEach CB series unit consists of an extruded aluminum backplane with an insulated strip containing copper busbars, along with an end feed, end cap and optional cord. The aluminum extrusion acts as a 100% ground path. Each unit is enclosed by means of cover pieces and plug-in modules (ordered separately). Available as 4-pole (3 phase + Neutral), and 4-pole with isolated ground conductor. The CB series is offered in 60 Amps (63 Amp IEC).
The CB series includes built-in hardware on the back of each unit that can be used to hang the device in a server cabinet.
Total length of your device will be your selected pluggable space plus 10 inches (254mm) to accommodate for the end cap and end feed (Refer to option 8. Plug-In Module Space on pg. 5.3 Cabinet Busway Series: Product Numbers)
6.2 | StarlinePower.com
Back Plane End Feed
End Cap
Pluggable Space
*Please note, a CB series unit only includes the backplane of the raceway, end feed, end cap and optional cord. Plug-in modules must be ordered separately (see section 6).
Cord
Plug
Spare Cover is provided
*2 mounting brackets are provided with each system
PIR Series
42 Installation, Operation and Maintenance Manual | PIR Series VERSION 1
PRODUCT SELECTION GUIDECabinet Busway Series
CABINET BUSWAY SERIES: PRODUCT NUMBERS
U CB P 060 240 - H M - 0206
- 0200 - 460P9S - L - 2 - SIL
1. System
2. ProductLine
3. Frame Type
5. Voltage
6.Ground Busbar
7.Metering
8.Plug-In Module Space
9.Cord Length
10.Connector Body
13.Paint Color
1. System (standard of measure)U U.S. M Metric
2. Product Line (section housing)CB Cabinet Busway
4. Product Frame (maximum amperage)060 60 amps (U.S.) 063 63 amps (Metric)
5. Voltage (voltage options)240 240 volts or 120/208 volts (U.S.)
480 480 volts (U.S.) 415 415 volts (Metric)
6. Ground Busbar (type of ground busbar)H Housing Ground G Isolated/Dedicated Ground
7. Current Monitoring (optional metering)M Metered Unit* N Non-Metered Unit
8. Plug-In Module Space (total length available for modules)0206 2 ft. 6 in. (U.S.) M080 .8 meter (Metric)0309 3 ft. 9 in. (U.S.) M120 1.2 meters (Metric)0500 5 ft. (U.S.) M160 1.6 meters (Metric) 0603 6 ft. 3 in. (U.S.) M200 2 meters (Metric)
9. Cord Length (cord length options)0000 no cord M060 .6 meter (Metric)0200 2 ft. (U.S.) M125 1.25 meters (Metric)0400 4 ft. (U.S.) M200 2 meters (Metric)0600 6 ft. (U.S.) M250 2.5 meters (Metric)0800 8 ft. (U.S.) M300 3 meters (Metric) 1000 10 ft. (U.S.)1200 12 ft. (U.S.)
13. Paint Color (color of module cover)SIL Paint UEC Silver BLK Paint UEC Black
WHT Paint UEC White
****RAL system can also be used; reference page 8.1
Examples:UCBP060240-HM-0500-0000-STNDRD-L-2-SIL= U.S., Cabinet Busway system, Power, 60 amp, 240 volts- Housing ground, Metered Unit- 5 feet pluggable space- no cord- wire clips, no cord- Left end feed location- 2 inches (50.8mm) tall- painted SilverMCBP063415-GN-M200-M060-560P7S-L-2-WHT = Metric, Cabinet Busway system, Power, 63 amp, 415 volts- Isolated ground, Non-metered Unit- 2 meters pluggable space- .6 meter cord- 560P7S plug- Left end feed location- 2 inches (50.8mm) tall- painted White
**Total length of your device will be your selected plug-in module space plus 10 inches (254mm) to accommodate for the end cap and end feed
*If metering is selected, you must order a separate metering module on pgs. 7.1-7.2. Selecting metering will automatically reduce your plug-in module space by 10 inches (254mm)
10. Plug (plug options at end of cord)STNDRD Wire clips, no cord 560P9S460P9S 560P7S460P7S 563P6S04WIRE Terminal box 563P6W 05WIRE Terminal box
3. Frame Type (section housing)P Power D Power & Data
11. End Feed Location (side of end user connection)L Left
***Consult factory if end feed location of ‘right’ is necessary
4. Product Frame
11.End Feed Location
6.3 | StarlinePower.com
12.Height
12. Height (height of end feed cover)2 2 inches (50.8mm) 3 3 inches (76.2mm)
Installation, Operation and Maintenance Manual | PIR Series 43VERSION 1
PIR SeriesPRODUCT SELECTION GUIDE
U RM C S 020 S - P11 H - 1 - 515DGY
- SIL
Plug-In Modules
PLUG-IN MODULES: PRODUCT NUMBERS
7.7 | StarlinePower.com
Examples:URMCS060S-P11H-1-515DGY-SIL = U.S., Raceway Module, Circuit Breaker, Single breaker, 60 amp, Standard unlocked- P11 module, Housing ground- 1 device- 515D device, Gray receptacle, painted SilverMRMES063S-P12H-1-316A6SGY-SIL = Metric, Raceway Module, Circuit Breaker D Curve, Single breaker, 63 amp, Standard unlocked- P12 module, Housing ground- 1 device- 316A6S device, Gray receptacle- painted Silver
1. System (standard of measure)U U.S. M Metric
2. Product (section housing)RM Raceway Module
12. Paint Color (color of module cover)SIL Paint UEC Silver BLK Paint UEC Black
WHT Paint UEC White
12. Paint Color
2. Product
1. System
9. Quantity (number of devices as selected in #10.)1 1 device 2 2 devices3 3 devices 4 4 devices
3. Protection
4. Number of Breakers
5. Amperage
7. Box
8. Ground
9. Quantity
10. Device
11. Receptacle Color
3. Protection (section component)C Circuit Breaker (UL listed) O Outlet Box
B Circuit Breaker C Curve (IEC listed) F Fused Box
E Circuit Breaker D Curve (IEC listed)
4. Number of Breakers (reference table on pgs. 6.8 & 6.9)S Single M Multiple
N None (0)
5. Amperage (paddle compatibility)020 20 amps (U.S. & Metric) 060 60 amps (U.S.)
063 63 amps (Metric)
7. Box (what module/enclosure)P11 10”(254mm)L x 2"(50.8mm)H P21 15”(381mm)L x 2"(50.8mm)H
P12 10”(254mm)L x 2.5"(63.5mm)H P22 15”(381mm)L x 2.5"(63.5mm)H
P13 10”(254mm)L x 3"(76.2mm)H P23 15”(381mm)L x 3"(76.2mm)H
8. Ground (what type of ground is installed)H Housing D Dedicated
G Isolated
10. Device (NEMA or IEC configuration)*For a complete list of NEMA & IEC configurations, see pg. 6.8 - 6.9
11. Color (receptacle color (not all colors available for all devices; consult factory))GY Gray RD Red
WH White BK Black
BL Blue IV Ivory
6. Lock
6. Module Locking Options (security for unit)S Standard L Module Lock** *RAL system can also be used; reference page 8.1
*
**The image to the left shows a plug-in module with 'module lock'. This feature prevents the removal of the plug-in module from the straight, unless a special tool is used. Please refer to order option 6. for the purchase of this feature.
PIR Series
44 Installation, Operation and Maintenance Manual | PIR Series VERSION 1
PRODUCT SELECTION GUIDEProduct Number Resources
RAL Colors
9.1 | StarlinePower.com
1st Character 2nd Character 3rd Character
P Paint 0 100
1 101
2 102
3 103
4 200
5 201
A 300
B 301
C 302
D 303
E 400
F 401
G 500
H 501
J 502
K 600
L 601
M 602
N 603
P 700
Q 701
R 702
S 703
T 704
U 800
V 801
W 802
X 900
Y 901
Z 902
0 0
1 1
2 2
3 3
4 4
5 5
6 6
7 7
8 8
9 9
Example:
P B 2 = Paint RAL 3012
Installation, Operation and Maintenance Manual | PIR Series 45VERSION 1
PIR SeriesINSTALLATION INSTRUCTIONS
3Section 3Installation Instructions
PIR Series
46 Installation, Operation and Maintenance Manual | PIR Series VERSION 1
INSTALLATION INSTRUCTIONS1
1
2
2
3
3
4
4
A A
B B
C C
D D
ELECTRIC CORPORATION
SCALE SHEET
TITLESYSTEM LAYOUT - DUAL
1
DRAWING NUMBER
F2400002 DRAWN BY DATE
APPROVED BY DATE6/16/2016
6/16/2016tem
eschultz
Welding & Assembly Tolerances
DECIMALSx ± 1"x.x ± 1
2 "x.xx ± 3
16 "Revision History REV DATE REV BY APR BY
AOriginal issue
6/16/2016 eschultz tem
ANGULARx ± 3°x.x ± 1.5°
*All welds, spot and continuous, are to be holding.Porosity and Worm Tracks are to be minimized.
*Unless otherwise noted, all fasteners are to behand-tightened and then turned 1/4 of a revolution.
F2400002 - ( S/R) C - H1H2H3...Hx
Finished Goods Part Number Assignment
DESCRIPTION
(S/R) - Orientation
'S' - Standard 'R' - Reversed
C - Color (Paint) '0' - Unpainted '1' - Anodized Silver '2' - Gray '3' - Black '4' - White '5' - Galvanized, Bright '6' - Red '7' - Blue '9' - SP (Special)
Hx - Phase Configuration
'0' - N/A (None) '4' - [A-B-C]'A' - [A-N] '5' - [A-B-N]'B' - [B-N] '6' - [B-C-N]'C' - [C-N] '7' - [C-A-N]'1' - [A-B] '8' - [A-B-C-N]'2' - [B-C] '9' - SP (Special)'3' - [C-A]
POWER: 1:8
Power joint kit
JOINT KIT: 1:8
CROSS SECTION - POWER: 1:23.330 [84.58]
2.030
[51.5
6]
POLARIZATION STRIPE
(A) (G) (B) (N) (C)
6.000 [152.40]
2.045
[51.9
4]
CROSS SECTION - POWER / DATA: 1:2
POLARIZATION STRIPE
4.4 in² DATACOM RACEWAY
POWER AND DATA 1:8
PLUG-IN MODULES: 1:4 DATA PLUG-IN MODULE : 1:41.960 [49.78]
MANY VARIETIES IN TWO LENGTH SIZES EASY
INSTALLATION / REMOVAL
COVER PLATE CUTOUTS FOR WIDE VARIETY OF DATACOM INSERTS.
EXTERNAL HORIZONTAL ELBOW: POWER 1:8
INCLUDES (2) BUS CONNECTORS AND (2) BUS CONNECTOR KEEPERS
UP VERTICAL ELBOW: POWER 1:8
INCLUDES (2) BUS CONNECTORS AND (2) BUS CONNECTOR KEEPERS
EXTERNAL HORIZONTAL ELBOW: POWER/DATA 1:8
INCLUDES (2) BUS CONNECTORS AND (2) BUS CONNECTOR KEEPERS
UP VERTICAL ELBOW: POWER/DATA 1:8
INCLUDES (2) BUS CONNECTORS AND (2) BUS CONNECTOR KEEPERS
Installation, Operation and Maintenance Manual | PIR Series 47VERSION 1
PIR SeriesINSTALLATION INSTRUCTIONS
1
1
2
2
3
3
4
4
A A
B B
C C
D D
ELECTRIC CORPORATION
SCALE SHEET
TITLESYSTEM LAYOUT - DUAL
1
DRAWING NUMBER
F2400002 DRAWN BY DATE
APPROVED BY DATE6/16/2016
6/16/2016tem
eschultz
Welding & Assembly Tolerances
DECIMALSx ± 1"x.x ± 1
2 "x.xx ± 3
16 "Revision History REV DATE REV BY APR BY
AOriginal issue
6/16/2016 eschultz tem
ANGULARx ± 3°x.x ± 1.5°
*All welds, spot and continuous, are to be holding.Porosity and Worm Tracks are to be minimized.
*Unless otherwise noted, all fasteners are to behand-tightened and then turned 1/4 of a revolution.
F2400002 - ( S/R) C - H1H2H3...Hx
Finished Goods Part Number Assignment
DESCRIPTION
(S/R) - Orientation
'S' - Standard 'R' - Reversed
C - Color (Paint) '0' - Unpainted '1' - Anodized Silver '2' - Gray '3' - Black '4' - White '5' - Galvanized, Bright '6' - Red '7' - Blue '9' - SP (Special)
Hx - Phase Configuration
'0' - N/A (None) '4' - [A-B-C]'A' - [A-N] '5' - [A-B-N]'B' - [B-N] '6' - [B-C-N]'C' - [C-N] '7' - [C-A-N]'1' - [A-B] '8' - [A-B-C-N]'2' - [B-C] '9' - SP (Special)'3' - [C-A]
POWER: 1:8
Power joint kit
JOINT KIT: 1:8
CROSS SECTION - POWER: 1:23.330 [84.58]
2.030
[51.5
6]
POLARIZATION STRIPE
(A) (G) (B) (N) (C)
6.000 [152.40]
2.045
[51.9
4]
CROSS SECTION - POWER / DATA: 1:2
POLARIZATION STRIPE
4.4 in² DATACOM RACEWAY
POWER AND DATA 1:8
PLUG-IN MODULES: 1:4 DATA PLUG-IN MODULE : 1:41.960 [49.78]
MANY VARIETIES IN TWO LENGTH SIZES EASY
INSTALLATION / REMOVAL
COVER PLATE CUTOUTS FOR WIDE VARIETY OF DATACOM INSERTS.
EXTERNAL HORIZONTAL ELBOW: POWER 1:8
INCLUDES (2) BUS CONNECTORS AND (2) BUS CONNECTOR KEEPERS
UP VERTICAL ELBOW: POWER 1:8
INCLUDES (2) BUS CONNECTORS AND (2) BUS CONNECTOR KEEPERS
EXTERNAL HORIZONTAL ELBOW: POWER/DATA 1:8
INCLUDES (2) BUS CONNECTORS AND (2) BUS CONNECTOR KEEPERS
UP VERTICAL ELBOW: POWER/DATA 1:8
INCLUDES (2) BUS CONNECTORS AND (2) BUS CONNECTOR KEEPERS
PIR Series
48 Installation, Operation and Maintenance Manual | PIR Series VERSION 1
INSTALLATION INSTRUCTIONS
BEFORE YOU BEGIN
• Always wear appropriate PPE
• Please consult NFPA 70E for information on calculating incident energy for the location of your work, and the necessary associated PPE for your particular installation.
WARNING: Hazardous voltage will cause severe shock or burn. Ensure that all circuit breakers are in the ‘OFF’ position before installing onto the raceway. Modules may be installed on an energized system. Be sure that they are NOT installed under load.
Step 1
Step 2
INSTALLING A PLUG-IN MODULE
To install the module onto the raceway, first insure proper alignment of the plug-in module with the raceway before snapping the module on. The breaker/label/tab side of the module should face toward the polarizing strip.
Place the top leg of the plug-in module onto the backplane, making sure that there is contact, rotate the module until the lower leg makes contact with the backplane. You will hear a click. The plug-in module is now installed.
Breaker Side
PolarizingStripe
Installation, Operation and Maintenance Manual | PIR Series 49VERSION 1
PIR SeriesINSTALLATION INSTRUCTIONS
Step 1
REMOVING A PLUG-IN MODULE
To remove the plug-in module, press the 2 release buttons on the module to release the latching snaps. Then rotating up and away from the user, the module will release from the backplane.
Release Button
ReleaseButton
PIR Series
50 Installation, Operation and Maintenance Manual | PIR Series VERSION 1
PLUG-IN INSERTION INSTRUCTIONS
Installation, Operation and Maintenance Manual | PIR Series 51VERSION 1
PIR SeriesFIELD SERVICES AND WARRANTY
4Section 4Field Services and Warranty
PIR Series
52 Installation, Operation and Maintenance Manual | PIR Series VERSION 1
FIELD SERVICES AND WARRANTY
UNIVERSAL GLOBAL SERVICES
With over 30 years of experience in the market, Starline has the knowledge and expertise to ensure that your Plug-In Raceway system is functioning at a best-in-class level.
We are currently offering the following services:
Load Bank Testing and Equipment Rentals
Whether you are in need of rental equipment to test your power system or a team of technicians to test the system for you, Universal Global Services has you covered. Select testing equipment from our inventory of load banks and associated gear, or work with a UEC engineer to customize your own test plan to suit your individual needs.
Meter Services
Factory trained and certified technicians will provide comprehensive on-site meter commissioning that includes meter inspection, programming and detailed documentation. Our technicians will program CPM meters and offer optional integration services to your BMS or DCIM for any and all meters located within your facility.
Startup and System Certification
Certified technicians inspect and validate that the installation meets factory standards, ensuring ongoing reliability and compliance with facility safety requirements. Upon successful completion of system startup, Starline’s standard one (1) year manufacturer’s warranty will be automatically extended.
• Ensure all joint and feed connections are properly installed with continuity testing
• Ensure proper installation of all plug-in units
• Validate that system will perform to your specified requirements
• Full certification report delivered electronically at conclusion of service
Engineering Studies
Understanding the dangers and implementing a safety program is imperative to maintaining a safe work environment. Our professional engineers will conduct comprehensive facility electrical studies and recommend corrective actions, confirming your systems reliability and compliance with government and safety requirements.
Installation, Operation and Maintenance Manual | PIR Series 53VERSION 1
PIR SeriesFIELD SERVICES AND WARRANTY
On-Site Installation Support
On-site installation support begins by scheduling a site trip during your system installation. All work is performed by certified technicians- including review of installation best practices prior to the job, visual inspection of safe system installation, contractor installation oversight, and inspection and verification of functionality after rework.
On-Site Product Training
Certified technicians will provide a comprehensive training course curriculum that meets our high factory system standards, ensuring ongoing reliability of the system while also emphasizing operational safety. This course curriculum takes place in both a classroom and on-site with equipment.
Extended Warranty and Enhanced Service Plans
Ensure that your equipment investment is always covered. Select from an extended factory warranty or one of our many Enhanced Service Plans to meet your organizational requirements.
Contact your Starline Representative today to add services to your Plug-In Raceway order, or download detailed Statement of Work documents at http://downloads.uecorp.com/services.
Choice of Extended Warranty or Enhanced: Silver, Gold or Platinum Service PlansExtended1, 2, 3, 4
years
Silver1, 2, 3, 4
years
Gold1, 2, 3, 4
years
Platinum2, 3, 4 years
Repair or replacement of defective parts throughout life of service agreement X X X X
24/7 technical support hotline X X X X
Visual inspection of meters X X X
Visual inspection of all joints for visible gaps X X X
Update firmware and verify all Starline CPMs X X X
Includes travel and expenses X X X
One (1) service site visit per year X
Two (2) service site visits per year X X
Thermal imaging of all plug-in units X X
Thermal imaging of all joints X X
Thermal imaging of all end feed units X X
Detailed and fully executed thermography report X X
Online portal for test reports & documentation X X
Spare parts inventory management program X
PIR Series
54 Installation, Operation and Maintenance Manual | PIR Series VERSION 1
FIELD SERVICES AND WARRANTY
STANDARD FACTORY WARRANTY
Contractor/Customer: ___________________________________________________________
Customer Order: _______________________________________________________________
Seller warrants all products sold by Universal Electric Corporation to be free from defects in material or workmanship for a period of one year from the date of shipping. Seller’s liability on this warranty shall be limited to the repair or replacement of any product which is returned to the Seller, within one year of the date of delivery and which is found by the Seller to be defective in material or workmanship. Customer must have written authorization prior to returning any material to Universal Electric. The Buyer will be responsible for the cost of removing and reinstalling a defective part(s) or its replacement and all labor and material and all other costs or expenses incurred in connection therewith.
Notwithstanding any provision contained herein to the contrary, (i) Buyer’s use of any plug-ins, parts and/or components that are not manufactured by UEC with the Products, and/or (ii) if any services and/or warranties are provided by any person/entity other than UEC without UEC’s prior written consent, all warranties for all Products shall immediately terminate and be null and void.
Warranty Period: 1 year from delivery date
STANDARD FACTORY WARRANTY PROCESS
1. Customer calls either UEC Rep or UEC direct.
2. Customer Service Specialist will issue Return Material Authorization (RMA).
3. Customer returns warranted item along with copy of RMA.
4. UEC will either rework item or manufacture new item depending on the customer needs.
5. UEC ships item back to customer.
6. UEC will determine reason for failure.
7. Corrective action will be documented.
8. If reason for failure is requested by customer. UEC will send report to customer.
9. All action items from corrective action report must be completed by assigned designer and returned to Quality Department.
10. Quality Assurance Department will track all warranted events and report them to UEC Managers, Directors, and the Executive Team.
Installation, Operation and Maintenance Manual | PIR Series 55VERSION 1
PIR SeriesMAINTENANCE
5Section 5Maintenance
PIR Series
56 Installation, Operation and Maintenance Manual | PIR Series VERSION 1
MAINTENANCE
STARLINE RACEWAY RECOMMENDED MAINTENANCE
Starline's products are designed to be user friendly with no mandatory maintenance required. After proper installation, the joints, end feeds, and plug-in modules require little to no maintenance. Starline Plug-In Raceway uses boltless, compression type connection for the joining of conductors and sections. The end result is a reliable, heat tested connection at every joint that takes little to no maintenance over the life of the product.
The plug-in modules, joint connections, end feed connections, and mounting hardware can be checked at the user’s discretion, but is not required by Universal Electric Corporation.
IR inspection of the end feed connections, joints, and plug-in units can be checked at the user’s discretion, but is not required by Universal Electric Corporation.
We do recommend that the system be inspected periodically for physical damage or signs of any abnormalities.
Starline offers comprehensive on-going service plans that extend the life of the warranty over the duration of the plan. For more information, contact your Starline sales representative or email the factory at [email protected].
F0900073 07/18
For additional information regarding the Starline Plug-In Raceway system, please visit:http://www.starlinepower.com/raceway
United States 168 Georgetown Road | Canonsburg, PA 15317
UK & Northern EuropeUnit C Island Road | Reading RG2 0RP UK
Asia Pacific Region Office16D, Tuas Avenue 1 | #04-60/62 | JTC Space @ Tuas | Singapore 639536
S.W Asia Region OfficeGround Floor, E-1 Block, Beech Building | Manyata Embassy Business Park | Outer Ring Road | Bangalore, India 560045
Universal Electric Corporation (UEC), the manufacturer of Starline, has been a leader in powerdistribution since 1924. The company’s founders led the way for many new technologiesin the power distribution equipment industry. Today, this family tradition of innovationcontinues to pave the way for safer, more innovative and more reliable electrical powerdistribution systems. Visit www.StarlinePower.com for your flexible power solutions.