INSTALLATION MANUAL for the Application iHC-MIRF
ContentsIntroduction 3
Installing the application on a mobile phone 3
Settings 4
Control 12
02-203/2016 rev.8
3 / 14
Installation manual iHC-MARF
ELKO EP, s.r.o. | Palackého 493 | 769 01 Holešov - Všetuly | Czech Republic | e-mail: [email protected]
www.elkoep.com
• Introduction
The applications iHC-MIRF (for mobile phones with IOS) are designed for comfortable control of the RF Control electrical installation using your mobile telephone.
This is an RF Control system accessory, and as a part of the iNELS Smart Home Solution, its elegance blends in with any modern home. The menu is divided into clearly
structured sections in which the icons indicate individual functions. Here you will also fi nd faster access to your favorite functions, and you will maintain a constant clear
view of what‘s happening in and around your home.
Thanks to iHC-MIRF (the „application“), you can perfectly control the function of your wireless RF Control electrical installation. You thus keep complete control over your
home lights, appliance switching and heating.
The application only works with the device eLAN-RF-003 or eLAN-RF-Wi-003. This unit must be used in your wireless installation.
• It is designed for devices with IOS 8.0 and higher.
• It is optimized for devices with a display resolution of 800x480
• The application language follows the language set in the IOS
Implemented communication with Axis video cameras, thanks to which you can monitor what‘s going on around your home.
It also enables control for multiple users at once (by entering multiple IP addresses).
It enable creation of week-long programming or communicating with temperature units.
Setting options:
• max. number of actuator per application- 40
• max. number of time schedules (for dimming and switching)- 16
• max. number of time schedules, heating- 16
• max. number of actuators in one schedule - 8
• max. number of intervals in one schedule - 8
• max. number of heating circuits - 16
• max. number of heating and cooling devices in one heating circuit – 10
• max. number of central sources - 10
Downloading:
Download the current version (named iHC-MIRF) at the Apps store.
https://itunes.apple.com/cz/app/inels-home-control-rf-for/id704493937?mt=8
- Connect to the Internet using your mobile telephone.
- Activate the service app store.
- In the search bar, enter the password iNELS and press Search.
- Select the application iNELS Home Control RF Mobile for iPhone from the list and open the dialog box with information on this application.
- Click on Install.
- After the application is successfully installed in the phone, instead of the button Install, the button Open appears.
• Installing the application on a mobile phone
02-203/2016 rev.8
4 / 14
Installation manual iHC-MARF
ELKO EP, s.r.o. | Palackého 493 | 769 01 Holešov - Všetuly | Czech Republic | e-mail: [email protected]
www.elkoep.com
• Settings
The application iHC-MARF is designed for controlling the installation so that once started, it immediately off ers control over the electrical installation. To achieve this with
as few presses as possible, you must fi rst set up and confi gure the application.
Initial display upon running the application*:
Basic upper bar of the
telephone Tab Cameras
Tab Scenes
The home application
desktop. After
confi guring, the basic
tiles of the control
system are displayed.
Help button
Tab Favorites
Tab Settings
Tab - eLAN Settings
• Manually adding eLAN-RF: If you know the IP address eLAN-RF to which you want to connect, you can press the button Add. Enter its name (any name) and IP address.
• Automatic search: Press the icon search. Discovered eLAN-RF units appear that are located in your network to which you are currently connected by phone (home network).
Setting the IP address
of the communication
interface, by means of
which the telephone
communicates with
the wireless units
eLAN-RF
Selection for the
basic confi guration of
the application and
device, eLAN-RF device
settings. Confi guration
of the project of the
installation, assigning
addresses, pairing
actuators, assigning
icons, etc.Selection for setting
the tab Heating
Selection for setting
the tab Scenes
Selection for setting
the tab Others
Selection for setting
the tab Favorites
Selection for setting
the tab Cameras
Icon Search
Button for manually
adding eLAN-RF
By pressing Refresh,
you can restart a
search for eLAN-RF in
your network
Selection of the
required eLAN-RF
Searched
eLAN-RF
Any name will suffi ce
By pressing Settings, the basic application settings menu displays.
* If eLAN is connected with the application, the top bar is blue. A grey bar shows loss of connection between eLAN and application.
By pressing the required eLAN-RF, a window opens up for you to name it.
After entering the name, confi rm by pressing OK (if manually entering, the
eLAN-RF is named when added).
In this device list, you can have several eLAN-RF devices and IP addresses
confi gured. Here you can introduce one eLAN-RF even with two IP
addresses (with an internal IP address for the home network and a public IP
address for remote communication).
For the application to run properly, you must highlight it in the list of the eLAN-RF with
which the application is to primarily communicate 10s after designating the application
starts automatically downloading all the settings from eLAN-RF (if eLAN is already
coupled to RF).
By pressing Back, you return to the settings menu.
If you have already set up the eLAN-RF, click Back to go back to the desktop with set-up
units.
If you are setting up the eLAN-RF for the fi rst time, continue setting it up according to
the manual.
02-203/2016 rev.8
5 / 14
Installation manual iHC-MARF
ELKO EP, s.r.o. | Palackého 493 | 769 01 Holešov - Všetuly | Czech Republic | e-mail: [email protected]
www.elkoep.com
Tab - Confi guration
By pressing the tab Confi guration, you will arrive at the basic settings menu.
• Rooms
In the fi eld Name of room, you can enter any name (even with
diacritical marks)
In the fi eld Select room type, choose the room icon.
If you only create one room, the device is displayed directly on
the desktop.
Button for saving the
selected room
• Units
To add a unit that you want to control through the application,
you must fi ll in the fi elds:
1. Name of unit - any name
2. Enter the unit address – the address is a six-digit code listed on
the unit box.
3. Type of unit - select type of unit.
4. Temperature off set - set the off set (if the temperature from the
actuator sensor diff ers from the true ambient temperature) -
only for Thermal elements.
5. Select type of icon to be displayed.
Removing a unit – by a long press on the given unit.
Modifi cation / renaming – by a short press on the given unit, you
will open the settings options.
Entering any name of
unit
Window for selecting
unit type
Entering added unit
address
Window for selecting
icon type
Button for saving the
added device Added units
Button for adding
Rooms
Window for selecting
room icon
Window for name of
room
• Add units
After adding rooms and all required units, it is a good idea for a
clearer picture to assign units to individual rooms, in which they
are found (not a condition).
Select the room in the menu Add units. By pressing, you assign
the unit to the selected room.
By pressing Next, you can select the next option and continue
assigning.
Upon a change in assigned units, continue the same way – by
pressing, you change the device selection status.
Selection of the room for
adding units
Confi rmation button
upon selecting the unit
Next button for
continuing and
consequent saving
Modify the off set
02-203/2016 rev.8
6 / 14
Installation manual iHC-MARF
ELKO EP, s.r.o. | Palackého 493 | 769 01 Holešov - Všetuly | Czech Republic | e-mail: [email protected]
www.elkoep.com
• Plan
In the plan, you can set the desired function element depending
on day and time.
In the Name fi eld, type the name of schedule.
In the Elements 1 - 8 mark the elements that you want to associate
with the plan. One plan can be assigned to the elements of
one type. Confi rm by pressing OK. Displays menu functions for
diff erent types of elements:
- Switching: the possibility of setting ON / OFF
- Switch for blinds: blinds up / down.
- Dimming: 3 adjustable levels of brightness and illumination up
to 100%.
Upon pressing the Next button a graph appears, where you can
set the schedule function.
When creating a plan, you will see a graph displayed for Monday.
Click (+) New you can set the time intervals (in hours and minutes)
and choose the desired function. You can create up to eight time
periods for one day, which you can change at any time during use.
You can set the timetable by using the Copy (+), this allows you to
copy to other days. By pressing All-copy you can schedule all the
days of the week.
Pressing the Save button saves the settings.
Pressing expands all the
elements associated
with the schedule
Schedule for the
diff erent levels of
brightness with a
dimmer feature
Modify / delete the time interval.
In the required time plan, press Next. By a long press right on the
time interval, you open a table for modifying the time or deleting
the interval.
Save the time interval modifi cation by pressing Save and then
confi rming by pressing Save settings.
Fast modifi cation of time interval.
Shortly press the time interval, and it will set the sliders. You can
modify the interval as needed by simply moving the sliders to the
sides.
Vertical time interval
slider
02-203/2016 rev.8
7 / 14
Installation manual iHC-MARF
ELKO EP, s.r.o. | Palackého 493 | 769 01 Holešov - Všetuly | Czech Republic | e-mail: [email protected]
www.elkoep.com
Control using a time schedule
The fi rst step is selecting the central heating source (if it is necessary to control it) e.g. switching
on an electric boiler.
The next step is placing units for temperature control (heating units, switches, thermovalves)
in the required space (room).
You can have units placed in the required room for temperature control even without
controlling the central heating.
Assigning modes:
1. Time plan for heating, which you want to use.
In the fi eld Name, enter the name of the heating program
In the fi eld Hysteresis, select the required hysteresis in a range of 0.5-5°C.
Setting heat modes - by pressing on the window beside the time modes, you can modify
temperatures for individual rooms.
In the lower right corner, press Next.
Confi rmation button
upon selecting the unit
Name the thermo-valve
Window for selecting
unit type
Thermo-valve address
Window for selecting
icon type
Naming the time plan
Selectable hysteresis
Adjustable temperatures
for individual modes
Once the menu
drops down, select the
temperature by means
of pickers
Selection for setting
the tab Heating
Tab - Heating
You can control heating in the application from the central source
to control e.g. of a RFATV-1 thermovalve mounted on a heater
valve.
Direct control of thermo-valve RFATV-1
You can add thermo-valve to the room as a separate unit, without
having to be assigned to the heating area. Thermo-valve has a
built in temperature sensor. App lets you operate your heating
(where thermos-valve is installed).
Modify the off set
02-203/2016 rev.8
8 / 14
Installation manual iHC-MARF
ELKO EP, s.r.o. | Palackého 493 | 769 01 Holešov - Všetuly | Czech Republic | e-mail: [email protected]
www.elkoep.com
Setting the start of the
time interval
The graph appears, where you set the time plan of heating
modes.
By default, the heating mode Minimum is set throughout the
week throughout a 24-hour time axis.
When creating a time plan, you will see displayed the heating
mode for Monday. By pressing (+) New, you can set the time
intervals (in hours and minutes) and select a heating mode for
them. You can create up to 8 time intervals for a single day, which
can be changed at any time during use.
By pressing (+) Copy to , you can copy the set time schedule to
other days. By pressing All, you will copy over the time schedule
to all days of the week.
By pressing the button Save, you can save the settings.
Modify / delete the time interval.
In the required time plan, press Next. By a long press right on the
time interval, you open a table for modifying the time and mode
or deleting the interval.
Save the time interval modifi cation by pressing Save and then
confi rming by pressing Save settings.
Fast modifi cation of time interval.
Shortly press the time interval, and it will set the sliders. You can
modify the interval as needed by simply moving the sliders to the
sides.
Vertical time interval
slider
Modifi ed time interval
Option of changing the
interval time
Time interval
Heating modes with
set temperature
Button for copying the
daily plan
Slide for setting further
daysSet day
Button for adding a time
interval
Button for savingName
Setting the end of the
time interval
Setting the end of the
time interval
Button for storing the
modifi ed time interval
Button for deleting time
interval
Option of changing the
heat mode
02-203/2016 rev.8
9 / 14
Installation manual iHC-MARF
ELKO EP, s.r.o. | Palackého 493 | 769 01 Holešov - Všetuly | Czech Republic | e-mail: [email protected]
www.elkoep.com
2. Heating circuits (heating rooms) to which you can
assign time plans.
Press Heating circuit, and by pressing Add at the bottom right, you
will create a new heating circuit.
Name – enter the name of the heating circuit (e.g.: Room 1)
Select the temperature sensor - select the required unit with
temperature sensor (e.g. RFATV-1). Some units have two
temperature sensors - internal and external - selected the
required one*.
Select the temperature plan – from the set menu.
Select holiday plan - a set menu. The schedule is be activated
by one press and is used for temporary discontinuation of the
extended schedule (not a condition).
Select heating - here select the units found in the given area and
those that you want to control heating of a room. If you have
a controlled central heating source, you can assign it to the
selected heating
For easier control, we recommend creating a separate room for
heating circuits, into which you will assign all heating circuits.
* RFSTI-11/G: a choice between internal and external sensors and
mixedmode (mixed mode - measured space temperature sensor internal
and external sensor monitors the critical temperature of the fl oor, when
exceeding of the critical temperature occurs the fl oor heating is turned off
regardless of the temperature measured by the internal sensor).
Select the name of the
heating circuit Select the heating that
the room contains
Selection of central
heating source
Press to display the
heating selection
Select the temperature
plan
3. Central source
Press Central source, and by pressing Add at the bottom right, you
will create a new central source.
Name – enter the name of the central heating source.
Unit – select the unit by which you switch on the central source.
Heating circuit – indicate the heating circuits that you want linked
to the central source.
Save by pressing Save.
Select the unit for the
central heating source
Assigning a central
heating source to the
heating circuit
Name of central heating
source
Button for saving the
central heating source
Tab - Favorites
By pressing Add, a list opens of confi gured devices, which you
will designate with. After pressing Save, it is assigned to the list
in the Favorites tab.
Field for selecting the
device in the Favorites
tab
Button for saving
the Favorites tab
confi guration
List of all devices
confi gured in eLAN-RF
Select the temperature
sensor
THERMO-VALVE
Select the temperature
plan
02-203/2016 rev.8
10 / 14
Installation manual iHC-MARF
ELKO EP, s.r.o. | Palackého 493 | 769 01 Holešov - Všetuly | Czech Republic | e-mail: [email protected]
www.elkoep.com
Tab - Scenes
The list of scenes is used to activate the user‘s predefi ned scenes,
such as all off , all on, all blinds up, all on - all blinds down, etc.
After pressing the Scenes tab, press Add.
Name – enter the name of the light scene.
By designating you select the units you want to assign to the light
scene.
When fi nished selecting, press Next.
Choose the functions of the single units you wish to perform
when launching the scenes.
Name the scene
The Next button for
selecting units switches
to the display for
setting the functions of
selected units
Scroll bar of selected
units in the created
scene. Primarily, units
are selected at the
middle position of the
scroll bar - under the
scene name
Field for selecting
from used units for
confi guration in the
Scenes tab
Tab - Cameras
If you wish to have video cameras always at hand, you can add
them to the quick display - Tiles.
In the iHC application, you can also view the current image
(stream) from home security Axis IP video cameras, custom.
By pressing Save, you will open the menu with settings to Axis IP
video cameras.
Note: When using other than the recommended IP cameras
custom, format of stream requires mjpg. Please insert this format
in the column Enter an address of camera.
To access your stream please use e.g. web interface or check in
the camera manual. If the stream is not in a format MJPG, the App
connection attempt will fail.
Example:
Address format: ip address:port/mjpg/video.mjpg
Address format example: 10.10.5.142:80/mjpg/video.mjpg
After fi lling in items on the display, press Save. The application
saves the settings and automatically adds the video camera to
the list of devices in the Cameras tab.
Removing a video camera from the list – by a long press on the
given item in the list.
The application allows full screen video camera display; press and
hold the relevant video camera view to open the PTZ panel to
control it (if the PTZ camera supports it).
Field for arbitrary
naming of the IP video
camera e.g. Living room
Field for entering the
log-in name to the
added IP video camera
Field for displaying
the IP address of the
installed video camera
Field Type of video
camera - selection fi eld
with menu of video
camera manufactures
iNELS cam, Axis and
custom.
Field for entering the
log-in password to the
added IP video camera
At the dimmer settings
function, set the
required brightness that
the unit sets when the
scene is activated
Cameras tab with
defi ned video cameras
and camera view in
the tile position on the
desktop
PTZ control elements
Open tile of the defi ned
IP video camera in the
iHC application. The
video image (stream)
from the video camera
now automatically
reverses based on the
telephone‘s approved
services
CAMERA
ROOM
02-203/2016 rev.8
11 / 14
Installation manual iHC-MARF
ELKO EP, s.r.o. | Palackého 493 | 769 01 Holešov - Všetuly | Czech Republic | e-mail: [email protected]
www.elkoep.com
eLAN upload status
Clear saved settings
Information on the
progress of update
Tab - Other
• In the selection fi eld Display panel Favorite items after startup,
set the list of favorite items on the start page after starting the
application.
• In the selection fi eld Receive notifi cations on new fi rmware - set
automatic checking of availability of the newest version of
fi rmware for your eLAN-RF, and you will receive notifi cations to
your mobile phone.
After receiving notifi cation, the application will ask you to
update in the form of a red circle with an exclamation point.
Pressing the button with the update off er will lead you to the
menu Other. By pressing Update eLAN, the fi rmware in your
eLAN-RF will be automatically updated.
After using the function Receive notifi cations on new fi rmware,
you must have an Internet connection via Wi-Fi network or
mobile data.
• Enable checking of the time in eLAN - function monitors eLAN
time synchronization and applications (eg. If eLAN is not
connected to the Internet). If the diff erence is more than 5
minutes, the application displays a warning.
• Item Download newest fi rmware version is used to download the
latest fi rmware version into your mobile telephone.
In case you already have the current fi rmware installed in your
mobile phone, it off ers you the option to delete it.
To use the function Receive notifi cations on new fi rmware, you
must have an Internet connection via Wi-Fi network or mobile
data.
After connecting your telephone to the eLAN-RF device, you
can press Update eLAN (in the menu Other), update fi rmware in
eLAN-RF.
Thanks to this, you have the option of updating the fi rmware
in the device eLAN-RF even in places where an Internet
connection is not available.
• Download settings eLAN - function allows you to download
the current settings for the connected eLAN-RF directly to your
phone. *
Backup settings are stored in memory on your telephone.
• Record eLAN settings- displays the saved settings for eLAN that
you can upload from your phone to the currently connected
eLAN.
• License – displays information
• Upgrade feature - when updating fi rmware from eLAN version
2.7.012 or higher it is required to press the button (the new
features are already assigned to the set features).
• The application version is uploaded to your phone.
* After confi guration is recommended to save your settings for
the eLAN through an application or Web interface
Confi rmation button
for displaying the panel
Favorites after startup
Confi rmation button for
obtaining notifi cation
on availability of a new
fi rmware version of
eLAN-RF
Off er for update
Click to start update
Button after
downloading the latest
fi rmware version into a
mobile telephone
02-203/2016 rev.8
12 / 14
Installation manual iHC-MARF
ELKO EP, s.r.o. | Palackého 493 | 769 01 Holešov - Všetuly | Czech Republic | e-mail: [email protected]
www.elkoep.com
• Control
The main display in the iHC application is formed of so-called Tiles. This is
a general overview of rooms in the intelligent electrical installation iNELS
Home Control.
Based on the previous steps for settings, the initial tiles of the application
will appear on the screen:
• based on units in rooms (e.g. „rooms as in living room“)
• based on groups (e.g. „Lights or All“).
If you want to control individual units, press the required room to which
you have assigned the given unit.
If the confi guration is set up that there are more than 6 tiles on the default
display, switch between them by dragging your fi nger up/down along the
display, i.e. scrolling.
After displaying the list of units in a certain room, you can control
individual devices.
Output Status indicators are automatically updated when any status/
mode/temperature change occurs.
Warning: if you control the blinds using any other method eg. A key-chain,
wall or other controller., The application displays the current status of the
output. For correct display, perform a manual update of the status output.
The manual update of Output Status indicators can be activated (in the
case of the sleep mode) by dragging your fi nger across the screen (ie.
scrolling). Then the Output indicators will be updated.
• Auto Symbol feature, works automatically according to schedule.
• The timing symbol shows the current timing (for dimmers - start / stop,
with the switches - On- / Off -delay, with the switches for blinds - blinds
move).
Tile (room)
Symbol, icon assigned
to the given unit,
device
By a short press of the
unit tile, you can change
the unit status ON/OFF.
In case of blinds UP/
DOWN
You can scroll up and
down through the tiles
by dragging on the
screen
Controlling dimmers
If you hold your fi nger down on the device, you will see displayed e.g. for a dimmed light, a bar graph for setting the dimmed light brightness. Two buttons are displayed
underneath it - increase and decrease, enabling smooth dimming and brightening of the light. If the dimmer is assigned to the schedule the possibility of switching on /
off the Auto function will also be displayed. For the buttons increase and decrease, by pressing the arrows, a menu opens with options for setting the time of the increase /
decrease functions. While setting the time the automatic time setting must be off , after saving the settings turn on the automatic setting for correct function of the
schedule.
By pressing a dimmer with RGB control option, you will see the menu displayed for setting color, brightness and the brightening mode.
Press to initiate
gradual brightening
Bargraph for setting
the brightness
Press to initiate
gradual dimmingButton for setting
the time of the given
function
Button for setting
time
Circus mode -
automatic color
change
Currently selected
color
Setting the light RGB
brightness
Set time
minutes : seconds
Switching off /on the
RGB light
Settings of RGB light
color
Status bar of
monitored rooms
Basic overview of
confi gured tiles in the
application menu.
Button for
confi guring the system
and settings from the
application
Arrows for switching
between individual
rooms
Unit output status
indicator, or device
on - brightness at
70%. To bring up the
brightness setting, the
slider must be held on
the unit tile
Unit output status
indicator, or device
on, off
After setting the time,
press to confi rm
Pressing iNELS displays
the room set
Auto Symbol
Time Symbol
02-203/2016 rev.8
13 / 14
Installation manual iHC-MARF
ELKO EP, s.r.o. | Palackého 493 | 769 01 Holešov - Všetuly | Czech Republic | e-mail: [email protected]
www.elkoep.com
Controlling switches
For switches, you can run the function Delayed on / Delayed off and if the switch
is assigned to a Schedule it will also show the possibility of switching on / off the
Automatic function The delayed on / off time settings are set by pressing arrows
by the buttons. While setting the time the automatic time setting must be off ,
after saving the settings turn on the automatic setting for correct function of
the schedule.
For switches for controlling blinds, the movement time of the blinds is set in the same manner as for previous ones. Setting the time applies to both directions. If the switch is assigned to a Schedule it will also show the possibility of switching on / off the Automatic function. While setting the time the automatic time setting must be off , after saving the settings turn on the automatic setting for correct function of the schedule.
Button for raising blinds
Button for lowering
blinds
Setting the movement
time for blinds
Stopping the blinds
Thermo-valve control
If you press and hold (long press) the icon of assigned thermo-
valve to room, the settings will be displayed:
• Manual temperature control 0-32°C
• The set / recorded temperature
• Display status - battery, open thermo-valve, the window status
• Adjusting the open window sensitivity
• Open window off time
With any manipulation of batteries RFATV-1 (eg. Replacement)
always recalibrate the thermal valve *.
Controlling the temperature control
Heating circuits can be controlled right from the rooms in which
they were assigned.
For heating circuits in the room, the following is displayed:
1. Current heating mode to the given heating circuit.
2. Current temperature of sensor at the unit assigned to the
heating circuit.
3. Heating circuit status – backlit icon – circuit is active, heating.
Display the battery‘s
status
Display the status of
open thermo-valve
Display the current
temperature
Set temperature
Buttons for quick
temperature correction
Display the open
window function
Current temperature of
temperature circuit
Display of the current
heating circuit mode
Heating circuit status
Indication of dead
battery at the unit
By a long press of the
heating circuit, you will
open the settings
Manual temperature
adjustment
Adjust the open window
sensitivity
Time setting of the open
window
Indication of the unit
already assigned in the
heating area
After setting the time,
press to confi rm
*Calibrating the RFATV-1:
1. open the battery cover
2. remove the batteries
3. after 30s, insert new batteries (observe the polarity)
4. close the battery cover
5. using a „key“, press the blue button. The thermovalve itself will fi nd the extreme position open and
closed on its own. During calibration, do not touch the thermovalve. A fl ashing green LED diode on the
thermovalve indicates the end of calibration.
For delayed on/off ,
you can extend the
time for up to one hour
Blue light - switched on
Greyed out - off
Confi rm the time
02-203/2016 rev.8
14 / 14
Installation manual iHC-MARF
ELKO EP, s.r.o. | Palackého 493 | 769 01 Holešov - Všetuly | Czech Republic | e-mail: [email protected]
www.elkoep.com
Heating circuit functions
The heating circuit monitors the temperature by means of a selected sensor in the room. Once the temperature drops below the set level +/- of the hysteresis, the units in
the room determined for heating begin to heat, (the thermovalve opens on the heater valve, the relay at the heater switches on, etc.)
Change of heating mode in the circuit – by a long press, you will open the required circuit, and based on the current requirement, you can:
- change the heating mode
- manually adjust the temperature 0.5 - 5°C
- switch on/off the entire circuit (regardless of its time plan)
- set the function - sensitivity to an open window (displayed only when the temperature circuit is assigned to a thermo head)
- inform on battery status
- inform on current and set temperature
After manual adjustment of the heating mode, the heating circuit in the following set time interval returns, and will continue to work according to the set time plan
You can manually adjust the temperature at any time by +/- 5°C, the corrected temperature is only for the current time interval.
By pressing , you switch on/off the entire heating circuit regardless of its time plan.
By pressing the button for setting the function window sensitivity, you can set the sensitivity and time of switching off the heating while the window is open. Here you will
fi nd information on the current status of the function.
If the heating circuit contains units that are battery powered and the application ascertains that one of the units has a weak or dead battery, the left part of the screen
displays the battery icon. By pressing the battery icon, a list is displayed of units needing a change of batteries.
Another method of displaying a dead battery is indicated directly on the main screen at specifi c units, (rooms). The icon is only informative.
In the correction wheel, the Set and Current temperatures are displayed.
Set temperature - set in the heating mode +/- temperature correction adjusted by user.
Current temperature – measured by temperature sensor of one of the connected units.
If an icon appears at one of the units in the form of a lock, this means that the unit is already assigned into some heating circuit.
The unit cannot be controlled where, by an accidental press, you did not switch on heating that you have set in a diff erent preselected time plan.
Heating circuit after power supply outage:
During the schedule - returns to the set timetable
When manually set - returns to the set timetable
If it is manually turned off - remains off .
5
4
3
6
2
1
11
7
8
9
10
12
13
1. Buttons for quick temperature correction
2. Set temperature correction
3. Battery status indicator
4. Automatic control of the heating circuit according to the selected heating plan
5. Holiday mode
6. ON/OFF
7. Manual temperature adjustment
8. Set temperature
9. Current temperature of heating circuit
10. Button for setting open window function
11. Temporary manual settings (function only applies until the next pre-set
schedule changes
12. Manually setting (it does not change if you do not switch to another mode)
13. Option of changing the heat mode