INSTALLATION MANUAL - Daikin€¦ · INSTALLATION MANUAL FXDQ15A2VEB FXDQ20A2VEB FXDQ25A2VEB...

20
INSTALLATION MANUAL FXDQ15A2VEB FXDQ20A2VEB FXDQ25A2VEB FXDQ32A2VEB FXDQ40A2VEB FXDQ50A2VEB FXDQ63A2VEB System Inverter Air Conditioners

Transcript of INSTALLATION MANUAL - Daikin€¦ · INSTALLATION MANUAL FXDQ15A2VEB FXDQ20A2VEB FXDQ25A2VEB...

Page 1: INSTALLATION MANUAL - Daikin€¦ · INSTALLATION MANUAL FXDQ15A2VEB FXDQ20A2VEB FXDQ25A2VEB FXDQ32A2VEB FXDQ40A2VEB FXDQ50A2VEB FXDQ63A2VEB System Inverter Air Conditioners. CE -

INSTALLATION MANUAL

FXDQ15A2VEBFXDQ20A2VEBFXDQ25A2VEBFXDQ32A2VEBFXDQ40A2VEBFXDQ50A2VEBFXDQ63A2VEB

System Inverter Air Conditioners

Page 2: INSTALLATION MANUAL - Daikin€¦ · INSTALLATION MANUAL FXDQ15A2VEB FXDQ20A2VEB FXDQ25A2VEB FXDQ32A2VEB FXDQ40A2VEB FXDQ50A2VEB FXDQ63A2VEB System Inverter Air Conditioners. CE -

Dai

kin

Ind

ust

ries

Cze

ch

Rep

ub

lic s

.r.o

.

CE -

DECL

ARAT

ION-

OF-

CONF

ORM

ITY

CE -

KONF

ORM

ITÄT

SERK

LÄRU

NGCE

- DE

CLAR

ATIO

N-DE

-CO

NFO

RMIT

ECE

- CO

NFO

RMIT

EITS

VERK

LARI

NG

CE -

DECL

ARAC

ION-

DE-C

ONF

ORM

IDAD

CE -

DICH

IARA

ZIO

NE-D

I-CO

NFO

RMIT

ACE

- ∆H

ΛΩΣΗ

ΣΥΜ

ΜΟΡΦ

ΩΣΗ

Σ

CE -

DECL

ARAÇ

ÃO-D

E-CO

NFO

RMID

ADE

CE - ЗА

ЯВЛЕ

НИЕ-О

-СООТВ

ЕТСТ

ВИИ

CE -

OVE

RENS

STEM

MEL

SESE

RKLÆ

RING

CE -

FÖRS

ÄKRA

N-OM

-ÖVE

RENS

TÄM

MEL

SE

CE -

ERKL

ÆRI

NG O

M-S

AMSV

ARCE

- IL

MO

ITUS

-YHD

ENM

UKAI

SUUD

ESTA

CE -

PRO

HLÁŠ

ENÍ-O

-SHO

CE -

IZJA

VA-O

-USK

LAĐE

NOST

ICE

- M

EGFE

LELŐ

SÉG

I-NYI

LATK

OZA

TCE

- DE

KLAR

ACJA

-ZG

ODN

OŚC

ICE

- DE

CLAR

AŢIE

-DE-

CONF

ORM

ITAT

E

CE -

IZJA

VA O

SKL

ADNO

STI

CE -

VAST

AVUS

DEKL

ARAT

SIO

ON

CE - ДЕ

КЛАР

АЦИЯ

-ЗА-ϹЪ

ОТВ

ЕТСТ

ВИЕ

CE -

ATIT

IKTI

ES-D

EKLA

RACI

JACE

- AT

BILS

TĪBA

S-DE

KLAR

ĀCIJ

ACE

- VY

HLÁS

ENIE

-ZHO

DYCE

- UY

UMLU

LUK-

BİLD

İRİSİ

01ar

e in

conf

orm

ity w

ith th

e fo

llowi

ng s

tand

ard(

s) o

r oth

er n

orm

ative

doc

umen

t(s),

prov

ided

that

thes

e ar

e us

ed in

acc

orda

nce

with

our

instru

ction

s:02

der/d

en fo

lgend

en N

orm

(en)

ode

r eine

m a

nder

en N

orm

doku

men

t ode

r -do

kum

ente

n en

tspric

ht/e

ntsp

rech

en, u

nter

der

Vor

auss

etzu

ng,

daß

sie g

emäß

uns

eren

Anw

eisun

gen

einge

setzt

wer

den:

03so

nt co

nfor

mes

à la

/aux

nor

me(

s) o

u au

tre(s

) doc

umen

t(s) n

orm

atif(

s), p

our a

utan

t qu'i

ls so

ient u

tilisé

s con

form

émen

t à n

os in

struc

tions

:04

conf

orm

de

volge

nde

norm

(en)

of é

én o

f mee

r and

ere

binde

nde

docu

men

ten

zijn,

op

voor

waar

de d

at ze

wor

den

gebr

uikt o

vere

enko

msti

gon

ze in

struc

ties:

05es

tán

en c

onfo

rmida

d co

n la(

s) s

iguien

te(s

) nor

ma(

s) u

otro

(s) d

ocum

ento

(s) n

orm

ativo

(s),

siem

pre

que

sean

utili

zado

s de

acu

erdo

con

nues

tras i

nstru

ccion

es:

06so

no c

onfo

rmi a

l(i) s

egue

nte(

i) sta

ndar

d(s)

o a

ltro(

i) do

cum

ento

(i) a

car

atte

re n

orm

ativo

, a p

atto

che

ven

gano

usa

ti in

conf

orm

ità a

lleno

stre

istru

zioni:

07είναι

σύμφω

να με το(α)

ακόλουθο(α)

πρότυπο

(α) ή

άλλο έγγραφ

ο(α)

κανονισμώ

ν, υπ

ό την πρ

οϋπό

θεση

ότι χρησ

ιμοπ

οιούνται σύμφω

ναμε

τις ο

δηγίε

ς μας

:

08es

tão

em c

onfo

rmida

de c

om a

(s) s

eguin

te(s

) nor

ma(

s) o

u ou

tro(s

) doc

umen

to(s

) nor

mat

ivo(s

), de

sde

que

este

s se

jam u

tiliza

dos

deac

ordo

com

as n

ossa

s ins

truçõ

es:

09соответствую

т следую

щим

стандартам или другим

норма

тивным

докум

ентам,

при

условии

их использования согласно

наш

иминструкциям:

10ov

erho

lder

følge

nde

stand

ard(

er)

eller

and

et/a

ndre

ret

nings

given

de d

okum

ent(e

r), f

orud

sat

at d

isse

anve

ndes

i h

enho

ld til

vore

instru

kser

:11

resp

ektiv

e ut

rustn

ing ä

r ut

förd

i öv

eren

sstä

mm

else

med

och

följe

r fö

ljand

e sta

ndar

d(er

) ell

er a

ndra

nor

mgiv

ande

dok

umen

t, un

der

föru

tsättn

ing a

tt an

vänd

ning

sker

i öve

rens

stäm

mels

e m

ed vå

ra in

struk

tione

r:12

resp

ektiv

e ut

styr e

r i o

vere

nsste

mm

else

med

følge

nde

stand

ard(

er) e

ller a

ndre

nor

mgiv

ende

dok

umen

t(er),

und

er fo

rutss

etnin

g av

at

disse

bru

kes i

hen

hold

til vå

re in

struk

ser:

13va

staav

at s

eura

avien

sta

ndar

dien

ja m

uiden

ohje

ellist

en d

okum

enttie

n va

atim

uksia

ede

llyttä

en,

että

niitä

käy

tetä

än o

hjeide

mm

em

ukais

esti:

14za

pře

dpok

ladu,

že js

ou vy

užívá

ny v

soula

du s

našim

i pok

yny,

odpo

vídají

nás

ledují

cím n

orm

ám n

ebo

norm

ativn

ím d

okum

entů

m:

15u

sklad

u sa

slije

dećim

stan

dard

om(im

a) ili

dru

gim n

orm

ativn

im d

okum

ento

m(im

a), u

z uvje

t da

se o

ni ko

riste

u sk

ladu

s naš

im u

puta

ma:

16m

egfe

lelne

k az a

lábbi

szab

vány

(ok)

nak v

agy e

gyéb

irán

yadó

dok

umen

tum

(ok)

nak,

ha a

zoka

t előí

rás s

zerin

t has

ználj

ák:

17sp

ełniają

wym

ogi n

astę

pując

ych

norm

i inn

ych

doku

men

tów

norm

aliza

cyjny

ch, p

od w

arun

kiem

że

używ

ane

są z

godn

ie z

nasz

ymi

instru

kcjam

i:18

sunt

în c

onfo

rmita

te c

u ur

măt

orul

(urm

ătoa

rele)

sta

ndar

d(e)

sau

alt(

e) d

ocum

ent(e

) nor

mat

iv(e)

, cu

cond

iţia c

a ac

este

a să

fie

utiliz

ate

înco

nfor

mita

te cu

instr

ucţiu

nile

noas

tre:

19sk

ladni

z nas

lednji

mi s

tand

ardi

in dr

ugim

i nor

mat

ivi, p

od p

ogoje

m, d

a se

upo

rablj

ajo v

sklad

u z n

ašim

i nav

odili:

20on

vasta

vuse

s jär

gmis(

t)e st

anda

rdi(t

e)ga

või te

iste

norm

atiiv

sete

dok

umen

tideg

a, ku

i neid

kasu

tata

kse

vasta

valt m

eie ju

hend

itele:

21съответстват

на

следните

стандарти

или

други

норма

тивни

докуме

нти,

при

условие

, че

се

използват съгласно

наш

ите

инструкции

:22

atitin

ka že

miau

nur

odytu

s sta

ndar

tus i

r (ar

ba) k

itus n

orm

inius

dok

umen

tus s

u są

lyga,

kad

yra

naud

ojam

i pag

al mūsų

nuro

dym

us:

23ta

d, ja

lieto

ti atb

ilsto

ši ra

žotā

ja no

rādī

jumiem

, atb

ilst s

ekojo

šiem

stan

darti

em u

n cit

iem n

orm

atīvi

em d

okum

entie

m:

24sú

v z

hode

s n

asled

ovno

u(ým

i) no

rmou

(am

i) ale

bo in

ým(i)

nor

mat

ívnym

(i) d

okum

ento

m(a

mi),

za

pred

pokla

du, ž

e sa

pou

žívajú

v s

úlade

snaš

im n

ávod

om:

25ür

ünün

, tali

mat

larımıza

gör

e ku

llanı

lması k

oşulu

yla aşağı

daki

stand

artla

r ve

norm

beli

rten

belge

lerle

uyum

ludur

:

01Di

recti

ves,

as a

men

ded.

02Di

rekti

ven,

gem

äß Ä

nder

ung.

03Di

recti

ves,

telle

s que

mod

ifiées

.04

Rich

tlijne

n, zo

als g

eam

ende

erd.

05Di

recti

vas,

segú

n lo

enm

enda

do.

06Di

rettiv

e, co

me

da m

odific

a.07

Οδηγιών, όπ

ως έχ

ουν τροπο

ποιηθ

εί.08

Dire

ctiva

s, co

nfor

me

alter

ação

em

.09

Директив

со всем

и поправками

.

10Di

rekti

ver,

med

sene

re æ

ndrin

ger.

11Di

rekti

v, m

ed fö

reta

gna

ändr

ingar

.12

Dire

ktive

r, m

ed fo

reta

tte e

ndrin

ger.

13Di

rekti

ivejä,

sella

isina

kuin

ne ov

at mu

utettu

ina.

14v p

latné

m zn

ění.

15Sm

jernic

e, ka

ko je

izm

ijenje

no.

16irá

nyelv

(ek)

és m

ódos

ítása

ik re

ndelk

ezés

eit.

17z p

óźnie

jszym

i pop

rawk

ami.

18Di

recti

velor

, cu

amen

dam

ente

le re

spec

tive.

19Di

rekti

ve z

vsem

i spr

emem

bam

i.20

Dire

ktiivi

d ko

os m

uuda

tuste

ga.

21Ди

рективи,

с техните изме

нения.

22Di

rekty

vose

su p

apild

ymais

.23

Dire

ktīvā

s un

to p

apild

inājum

os.

24Sm

ernic

e, v

platn

om zn

ení.

25De

ǧiştir

ilmiş

halle

riyle

Yöne

tmeli

kler.

01fo

llowi

ng th

e pr

ovisi

ons o

f:02

gem

äß d

en V

orsc

hrifte

n de

r:03

conf

orm

émen

t aux

stipu

lation

s des

:04

over

eenk

omsti

g de

bep

aling

en va

n:05

siguie

ndo

las d

ispos

icion

es d

e:06

seco

ndo

le pr

escr

izion

i per

:07

με τή

ρηση

των δ

ιατάξεων

των:

08de

aco

rdo

com

o p

revis

to e

m:

09в соответствии

с положе

ниям

и:

10un

der i

agtta

gelse

af b

este

mm

elser

ne i:

11en

ligt v

illkor

en i:

12git

t i he

nhold

til b

este

mm

elsen

e i:

13no

udat

taen

mää

räyk

siä:

14za

dod

ržen

í usta

nove

ní pře

dpisu

:15

prem

a od

redb

ama:

16kö

veti a

(z):

17zg

odnie

z po

stano

wien

iami D

yrek

tyw:

18în

urm

a pr

eved

erilo

r:

19ob

upo

števa

nju d

oločb

:20

vasta

valt n

õuet

ele:

21следвайки клаузите

на:

22lai

kant

is nu

osta

tų, p

ateik

iamų:

23iev

ērojo

t pra

sības

, kas

not

eikta

s:24

održ

iavajú

c usta

nove

nia:

25bu

nun

koşu

lların

a uy

gun

olara

k:

01No

te *

as se

t out

in <A

> an

d jud

ged p

ositiv

ely by

<B>

ac

cord

ing to

the C

ertif

icate

<C>.

02Hi

nweis

*wi

e in <

A> au

fgefüh

rt un

d von

<B>

posit

iv be

urtei

lt ge

mäß

Zerti

fikat

<C>.

03Re

mar

que *

tel qu

e défi

ni da

ns <

A> et

évalu

é pos

itivem

ent p

ar

<B> c

onfor

méme

nt au

Cer

tifica

t<C>

.04

Bem

erk *

zoals

verm

eld in

<A>

en po

sitief

beoo

rdee

ld do

or

<B> o

vere

enko

mstig

Cer

tifica

at<C

>.05

Nota

*co

mo se

estab

lece e

n <A>

y es

valor

ado

posit

ivame

nte po

r <B>

de ac

uerd

o con

el

Certi

ficad

o<C

>.

06No

ta *

delin

eato

nel <

A> e

giudic

ato po

sitiva

mente

da

<B>

seco

ndo i

l Cer

tifica

to<C

>.07

Σημείωση

*όπ

ως κα

θορίζ

εται στο

<A>

και κρίν

εται θετικά

από

το <

B> σύμφω

να με το Π

ιστοπο

ιητικ

ό<C

>.08

Nota

*tal

como

estab

elecid

o em

<A> e

com

o par

ecer

po

sitivo

de <B

> de

acor

do co

m o C

ertif

icado

<C>.

09Пр

имечание

*как у

казано

в <A

> и в

соответствии

сп

олож

ительным

реше

нием

<B>

согласно

Св

идетельству<

C>.

10Be

rk *

som

anfø

rt i <

A> og

posit

ivt vu

rder

et af

<B>

ihen

hold

til Ce

rtifik

at<C

>.

11In

form

atio

n *

enlig

t <A>

och g

odkä

nts av

<B>

enlig

t Ce

rtifik

atet

<C>.

12Me

rk *

som

det fr

emko

mmer

i <A>

og gj

enno

m po

sitiv

bedø

mmels

e av <

B> ifø

lge S

ertif

ikat<

C>.

13Hu

om *

jotka

on es

itetty

asiak

irjass

a <A>

ja jo

tka <

B> on

hy

väks

ynyt

Serti

fikaa

tin<C

> mu

kaise

sti.

14Po

znám

ka *

jak by

lo uv

eden

o v <A

> a p

ozitiv

ně zj

ištěn

o <B>

vs

oulad

u sos

vědč

ením

<C>.

15Na

pom

ena *

kako

je iz

ložen

o u <A

> i p

ozitiv

no oc

ijenje

no

odstr

ane <

B> pr

ema C

ertif

ikatu

<C>.

16Me

gjeg

yzés

*a(

z) <A

> ala

pján,

a(z)

<B>

igazo

lta a

megfe

lelés

t, a(

z) <C

>ta

núsít

vány

szer

int.

17Uw

aga *

zgod

nie z

doku

menta

cją <

A>, p

ozyty

wną o

pinią

<B>

i Świ

adec

twem

<C>.

18No

tă *

aşa c

um es

te sta

bilit î

n <A>

şi ap

recia

t poz

itiv

de<B

> în

confo

rmita

te cu

Cer

tifica

tul<

C>.

19Op

omba

*ko

t je do

ločen

o v <

A> in

odob

reno

s str

ani <

B>

vskla

du s

certi

fikat

om<C

>.20

Märk

us *

nagu

on nä

idatud

doku

mend

is <A

> ja

heak

s kii

detud

<B>

järg

i vas

tavalt

serti

fikaa

dile

<C>.

21Забележка *

както е

изложе

но в

<A> и о

ценено

положи

телно

от <

B> съ

гласно

Сертификата<

C>.

22Pa

stab

a *ka

ip nu

statyt

a <A>

ir ka

ip tei

giama

i nus

pręs

ta <B

> pa

gal S

ertif

ikatą

<C>.

23Pi

ezīm

es *

kā no

rādīt

s <A>

un at

bilsto

ši <B

> po

zitīva

jam

vērtē

jumam

sask

aņā a

r ser

tifikā

tu<C

>.24

Pozn

ámka

*ak

o bolo

uved

ené v

<A>

a poz

itívne

ziste

né <

B>

vsúla

de s

osve

dčen

ím<C

>.25

Not *

<A>’d

a beli

rtildiğ

i gibi

ve <C

>Se

rtifik

asın

a gör

e <B

> tar

afınd

an ol

umlu

olara

k değ

erlen

dirild

iği gi

bi.

<A

>D

AIK

IN.T

CF.

024E

21/1

1-20

12

<B

>T

UV

(N

B18

56)

<C

>0

510

260

101

01 a

decla

res u

nder

its so

le re

spon

sibilit

y tha

t the

air

cond

itionin

g m

odels

to w

hich

this

decla

ratio

n re

lates

:02

der

klärt

auf s

eine

allein

ige V

eran

twor

tung

daß

die

Mod

elle

der K

limag

erät

e fü

r die

diese

Erk

lärun

g be

stim

mt is

t:03

fdé

clare

sous

sa se

ule re

spon

sabil

ité q

ue le

s app

areil

s d'ai

r con

dition

né vi

sés p

ar la

pré

sent

e dé

clara

tion:

04 l

verk

laart

hierb

ij op

eigen

exc

lusiev

e ve

rant

woor

delijk

heid

dat d

e air

cond

itionin

g un

its w

aaro

p de

ze ve

rklar

ing b

etre

kking

hee

ft:05

ede

clara

baja

su ú

nica

resp

onsa

bilida

d qu

e los

mod

elos d

e air

e ac

ondic

ionad

o a

los cu

ales h

ace

refe

renc

ia la

decla

ració

n:06

idic

hiara

sotto

sua

resp

onsa

bilità

che

i con

dizion

ator

i mod

ello

a cu

i è ri

ferit

a qu

esta

dich

iaraz

ione:

07 g

δηλώ

νει με α

ποκλεισ

τική της ε

υθύνη ότι τα μοντέλα των κ

λιματιστικών

συσ

κευώ

ν στα

οπο

ία αναφέρεται η

παρούσα

δήλωσ

η:08

pde

clara

sob

sua

exclu

siva

resp

onsa

bilida

de q

ue o

s mod

elos d

e ar

cond

icion

ado

a qu

e es

ta d

eclar

ação

se re

fere

:

09 u

заявляет

, исклю

чительно

под с

вою ответственность, что м

одели к

ондиционеров

воздуха, к которым

относится н

астоящ

ее за

явление:

10 q

erklæ

rer u

nder

ene

ansv

ar, a

t klim

aanlæ

gmod

eller

ne, s

om d

enne

dek

larat

ion ve

drør

er:

11 s

dekla

rera

r i e

gens

kap

av h

uvud

ansv

arig,

att

luftko

nditio

nerin

gsm

odell

erna

som

ber

örs a

v den

na d

eklar

ation

inne

bär a

tt:12

ner

klære

r et f

ullste

ndig

ansv

ar fo

r at d

e luf

tkond

isjon

ering

smod

eller

som

ber

øres

av d

enne

dek

laras

jon, in

nebæ

rer a

t:13

jilm

oitta

a yk

sinom

aan

omall

a va

stuull

aan,

että

täm

än ilm

oituk

sen

tark

oitta

mat

ilmas

toint

ilaitte

iden

mall

it:14

cpr

ohlaš

uje ve

své

plné

odpo

vědn

osti,

že m

odely

klim

atiza

ce, k

nim

ž se

toto

pro

hláše

ní vz

tahu

je:15

yizj

avlju

je po

d isk

ljučiv

o vla

stito

m o

dgov

orno

šću

da su

mod

eli kl

ima

uređ

aja n

a ko

je se

ova

izjav

a od

nosi:

16 h

telje

s fele

lőssé

ge tu

datá

ban

kijele

nti, h

ogy a

klím

aber

ende

zés m

odell

ek, m

elyek

re e

nyil

atko

zat v

onat

kozik

:

17 m

dekla

ruje

na włas

ną i w

yłącz

ną o

dpow

iedzia

lność

, że

mod

ele kl

imat

yzat

orów

, któ

rych

dot

yczy

nini

ejsza

dek

larac

ja:18

rde

clară

pe

prop

rie ră

spun

dere

că a

para

tele

de a

er co

ndiţio

nat la

care

se re

feră

ace

astă

dec

laraţ

ie:19

oz v

so o

dgov

orno

stjo

izjav

lja, d

a so

mod

eli kl

imat

skih

napr

av, n

a ka

tere

se iz

java

nana

ša:

20 x

kinnit

ab o

ma

täiel

ikul v

astu

tuse

l, et k

äeso

leva

dekla

ratsi

ooni

alla

kuulu

vad

kliim

asea

dmet

e m

udeli

d:21

bдекларира на

своя

отговорност

, че мо

делите

клим

атична

инсталация,

за ко

ито се

отнася тази

декларация:

22 t

visišk

a sa

vo a

tsako

myb

e sk

elbia,

kad

oro

kond

icion

avim

o pr

ietais

ų m

odeli

ai, ku

riem

s yra

taiko

ma

ši de

klara

cija:

23 v

ar p

ilnu

atbil

dību

apli

ecina

, ka

tālāk

uzs

kaitīt

o m

odeļu

gais

a ko

ndici

onētāji

, uz k

uriem

attie

cas š

ī dek

larāc

ija:

24 k

vyhla

suje

na vl

astn

ú zo

dpov

edno

sť, ž

e tie

to kl

imat

izačn

é m

odely

, na

ktoré

sa vz

ťahu

je to

to vy

hláse

nie:

25 w

tam

amen

kend

i sor

umlul

uǧun

da o

lmak

üze

re b

u bil

dirini

n ilg

ili old

uǧu

klim

a m

odell

erini

n aş

aǧıd

aki g

ibi o

lduǧu

nu b

eyan

ede

r:

EN

6033

5-2-

40,

3P323721-2A

Taka

yuki

Fu

jiiM

ana

ging

Dire

ctor

5th

of N

ovem

ber

201

2

01**

DICZ

*** is

aut

horis

ed to

com

pile

the

Tech

nical

Cons

tructi

on F

ile.

02**

DICZ

*** h

at d

ie Be

rech

tigun

g die

Tech

nisch

e Ko

nstru

ktion

sakte

zusa

mm

enzu

stelle

n.03

**DI

CZ***

est

auto

risé

à co

mpil

er le

Dos

sier d

e Co

nstru

ction

Tech

nique

.04

**DI

CZ***

is b

evoe

gd o

m h

et Te

chnis

ch C

onstr

uctie

doss

ier sa

men

te st

ellen

.05

**DI

CZ***

está

aut

oriza

do a

com

pilar

el A

rchiv

o de

Con

struc

ción

Técn

ica.

06**

DICZ

*** è

aut

orizz

ata

a re

diger

e il F

ile Te

cnico

di C

ostru

zione

.

07**

Η DI

CZ***

είναι εξουσιοδ

οτημένη να

συντάξει τον

Τεχνικό

φάκελο κατασκευής

.08

**A

DICZ

*** e

stá a

utor

izada

a co

mpil

ar a

doc

umen

taçã

o té

cnica

de

fabr

ico.

09**

Комп

ания

DIC

Z*** уполномо

чена

составить

Ком

плект т

ехнической

докум

ентации.

10**

DICZ

*** e

r aut

orise

ret t

il at u

darb

ejde

de te

knisk

e ko

nstru

ktion

sdat

a.11

**DI

CZ***

är b

emyn

digad

e at

t sam

man

ställa

den

tekn

iska

kons

trukti

onsfi

len.

12**

DICZ

*** h

ar til

latels

e til

å ko

mpil

ere

den

Tekn

iske

kons

truks

jonsfi

len.

13**

DICZ

*** o

n va

ltuut

ettu

laat

imaa

n Te

knise

n as

iakirja

n.14

**Sp

olečn

ost D

ICZ*

** m

á op

rávněn

í ke

kom

pilac

i sou

boru

tech

nické

kons

trukc

e.15

**DI

CZ***

je o

vlašte

n za

izra

du D

atot

eke

o te

hničk

oj ko

nstru

kciji.

16**

A DI

CZ***

jogo

sult a

műs

zaki

kons

trukc

iós d

okum

entá

ció ö

ssze

állítá

sára

.17

**DI

CZ***

ma

upow

ażnie

nie d

o zb

ieran

ia i o

prac

owyw

ania

doku

men

tacji

kons

trukc

yjnej.

18**

DICZ

*** e

ste a

utor

izat să

com

pilez

e Do

saru

l tehn

ic de

cons

trucţi

e.

19**

DICZ

*** je

poo

blašč

en za

sesta

vo d

atot

eke

s teh

nično

map

o.

20**

DICZ

*** o

n vo

litatu

d ko

osta

ma

tehn

ilist d

okum

enta

tsioo

ni.21

**DI

CZ***

е оторизирана

да състави Акта

за те

хническа

конструкция.

22**

DICZ

*** yr

a įga

liota

suda

ryti š

į tech

ninės

kons

trukc

ijos f

ailą.

23**

DICZ

*** ir

aut

orizē

ts sa

stādī

t teh

nisko

dok

umen

tācij

u.24

**Sp

oločn

osť D

ICZ*

** je

oprá

vnen

á vy

tvoriť

súbo

r tec

hnick

ej ko

nštru

kcie.

25**

DICZ

*** Te

knik

Yapı

Dos

yasını d

erlem

eye

yetki

lidir.

Mac

hine

ry 2

006/

42/E

CE

lect

rom

agne

tic C

ompa

tibili

ty 2

004/

108/

EC

** *

FX

DQ

15A

2VE

B,

FX

DQ

20A

2VE

B, F

XD

Q25

A2V

EB

, FX

DQ

32A

2VE

B, F

XD

Q40

A2V

EB

, FX

DQ

50A

2VE

B,

FX

DQ

63A

2VE

B,

***DI

CZ =

Daik

in In

dustr

ies C

zech

Rep

ublic

s.r.o

.

Page 3: INSTALLATION MANUAL - Daikin€¦ · INSTALLATION MANUAL FXDQ15A2VEB FXDQ20A2VEB FXDQ25A2VEB FXDQ32A2VEB FXDQ40A2VEB FXDQ50A2VEB FXDQ63A2VEB System Inverter Air Conditioners. CE -

VRV SYSTEM Inverter Air Conditioners Installation manual

CONTENTS1. SAFETY PRECAUTIONS................................................ 12. BEFORE INSTALLATION ............................................... 23. SELECTING INSTALLATION SITE................................. 34. PREPARATIONS BEFORE INSTALLATION.................. 45. INDOOR UNIT INSTALLATION ...................................... 56. REFRIGERANT PIPING WORK ..................................... 57. DRAIN PIPING WORK.................................................... 78. INSTALLING THE DUCT ................................................ 89. ELECTRIC WIRING WORK ............................................ 9

10. WIRING EXAMPLE ....................................................... 1011. FIELD SETTING AND TEST RUN ................................ 1212. WIRING DIAGRAM ....................................................... 14

The original instructions are written in English. All other lan-guages are translations of the original instructions.

1. SAFETY PRECAUTIONSPlease read these “SAFETY PRECAUTIONS” carefully before installing air conditioning equipment and be sure to install it cor-rectly.After completing installation, conduct a trial operation to check for faults and explain to the customer how to operate the air con-ditioner and take care of it with the aid of the operation manual. Ask the customer to store the installation manual along with the operation manual for future reference.This air conditioner comes under the term “appliances not accessible to the general public”.Meaning of WARNING and CAUTION notices

WARNING ............. Failure to follow these instructions properly may result in personal injury or loss of life.

CAUTION .............. Failure to observe these instructions properly may result in property dam-age or personal injury, which may be serious depending on the circum-stances.

WARNING

• Ask your dealer or qualified personnel to carry out installation work. Do not attempt to install the air conditioner yourself. Improper installation may result in water leakage, electric shocks or fire.

• Install the air conditioner in accordance with the instructions in this installation manual.Improper installation may result in water leakage, electric shocks or fire.

• Consult your local dealer regarding what to do in case of refrigerant leakage. When the air conditioner is to be installed in a small room, it is necessary to take proper mea-sures so that the amount of any leaked refrigerant does not exceed the concentration limit in the event of a leakage. Otherwise, this may lead to an accident due to oxygen deple-tion.

• Be sure to use only the specified accessories and spare parts for installation work. Failure to use the specified parts may result in the unit falling, water leakage, electric shocks or fire.

• Install the air conditioner on a foundation strong enough to withstand the weight of the unit.

A foundation of insufficient strength may result in the equip-ment falling and causing injury.

• Carry out the specified installation work after taking into account strong winds, typhoons or earthquakes.Failure to do so during installation work may result in the unit falling and causing accidents.

• Make sure that a separate power supply circuit is provided for this unit and that all electrical work is carried out by qual-ified personnel according to local laws and regulations and this installation manual. An insufficient power supply capacity or improper electrical construction may lead to electric shocks or fire.

• Make sure that all wiring is secured, the specified wires are used, and that there is no strain on the terminal connections or wires.Improper connections or securing of wires may result in abnormal heat build-up or fire.

• When wiring the power supply and connecting the remote controller wiring and transmission wiring, position the wires so that the control box lid can be securely fastened.Improper positioning of the control box lid may result in elec-tric shocks, fire or the terminals overheating.

• If refrigerant gas leaks during installation, ventilate the area immediately. Toxic gas may be produced if the refrigerant comes into con-tact with fire.

• After completing installation, check for refrigerant gas leak-age.Toxic gas may be produced if the refrigerant gas leaks into the room and comes into contact with a source of fire, such as a fan heater, stove or cooker.

• Be sure to switch off the unit before touching any electrical parts.

• Do not touch the switch with wet fingers.Touching the switch with wet fingers can cause electric shock.

• Be sure to earth the air conditioner. Do not earth the unit to a utility pipe, lightning conductor or telephone earth lead.Imperfect earthing may result in electric shocks or fire. A high surge current from lightning or other sources may cause damage to the air conditioner.

• Be sure to install an earth leakage breaker.Failure to install an earth leakage breaker may result in elec-tric shocks or fire.

CAUTION

• While following the instructions in this installation manual, install drain piping to ensure proper drainage and insulate piping to prevent condensation. Improper drain piping may result in indoor water leakage and property damage.

• Install the indoor and outdoor units, power cord and connect-ing wires at least 1 meter away from televisions or radios to prevent picture interference and noise.(Depending on the incoming signal strength, a distance of 1 meter may not be sufficient to eliminate noise.)

• Remote controller (wireless kit) transmitting distance can be shorter than expected in rooms with electronic fluorescent lamps (inverter or rapid start types).Install the indoor unit as far away from fluorescent lamps as possible.

• Only handle the indoor unit with gloves.

English 1

Page 4: INSTALLATION MANUAL - Daikin€¦ · INSTALLATION MANUAL FXDQ15A2VEB FXDQ20A2VEB FXDQ25A2VEB FXDQ32A2VEB FXDQ40A2VEB FXDQ50A2VEB FXDQ63A2VEB System Inverter Air Conditioners. CE -

• Do not install the air conditioner in the following locations: 1. Where there is a high concentration of mineral oil spray

or vapour (e.g. a kitchen). Plastic parts will deteriorate, parts may fall off and water leakage could result.

2. Where corrosive gas, such as sulphurous acid gas, is produced. Corroding of copper pipes or soldered parts may result in refrigerant leakage.

3. Near machinery emitting electromagnetic radiation. Electromagnetic radiation may disturb the operation of the control system and result in a malfunction of the unit.

4. Where flammable gas may leak, where there is carbon fibre or ignitable dust suspensions in the air, or where vol-atile flammables such as paint thinner or gasoline are han-dled.Operating the unit in such conditions may result in fire.

• Do not touch the heat exchanger fins.Improper handling may result in injury.

• Be very careful about product transportation.Some products use PP bands for packaging. Do not use any PP bands for a means of transportation. It is dangerous.

• Safely dispose of the packing materials.Packing materials, such as nails and other metal or wooden parts, may cause stabs or other injuries.Tear apart and throw away plastic packaging bags so that children will not play with them. If children play with a plastic bag which was not torn apart, they face the risk of suffocation.

• Do not turn off the power immediately after stopping operation.Always wait at least 5 minutes before turning off the power.Otherwise, water leakage and trouble may occur.

• In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures.

Follow national standards for installation work.

2. BEFORE INSTALLATIONThe accessories needed for installation must be retained in your custody until the installation work is completed. Do not discard them!

1. Decide upon a line of transport.

2. Leave the unit inside its packaging while moving, until reaching the installation site. Where unpacking is unavoid-able, use a sling of soft material or protective plates together with a rope when lifting, to avoid damage or scratches to the unit.

When moving the unit at or after opening, hold the unit by the hanger brackets. Do not apply force to the refrigerant piping, drain piping or flange parts.

Be sure to check the type of R410A refrigerant to be used before installing the unit.(Using an incorrect refrigerant will prevent normal opera-tion of the unit.)

For the installation of an outdoor unit, refer to the installation manual attached to the outdoor unit.

2-1 PRECAUTIONS• Be sure to instruct customers how to properly operate the

unit (operating different functions, and adjusting the temper-ature ) by having them carry out operations themselves while looking at the operation manual.

• Do not install in locations where the air contains high levels of salt such as that near the ocean and where voltage fluctuates greatly such as that in factories, or in vehicles or vessels.

2-2 ACCESSORIESCheck the following accessories are included with your unit.

2-3 OPTIONAL ACCESSORIES• This indoor unit requires one of the operation remote controls

listed below.

FOR THE FOLLOWING ITEMS, TAKE SPECIAL CARE DURING CONSTRUCTION AND CHECK AFTER INSTALLATION IS FINISHED.

a. Items to be checked after completion of work

NameMetal clamp (1)

Drain hose (2)

Insulation for fitting

Sealing pad

Quantity 1 pc. 1 pc. 1 each 1 each

Shape for liquid pipe (3)

for gas pipe (4)

Large (5)

mid. (6)

NameScrews for duct flanges (7)

Washer for hanging bracket (8)

ClampWasher fixing plate (11)

Quantity 1 set 8 pcs. 1 set 4 pcs.

Shape

Large (9)8 pcs.

small (10)4 pcs.

NameSealing material (12)

Air filter (13)

(Other)• Operation manual• Installation manual

(this manual)

Quantity 2 pcs. 1 pc.

Shape

Remote controller

Wired typeBRC1D52/BRC1D61/BRC1E51BRC2C51/BRC1E52/BRC3A61

Wireless type BRC4C62

Items to be checkedIf not properly done, what is likely to occur

Check

Are the indoor and outdoor unit fixed firmly?

The units may drop, vibrate or make noise.

Is the gas leak test finished? It may result in insufficient cooling.

Is the unit fully insulated? Condensate may drip.

Does drainage flow smoothly?

Condensate may drip.

Does the power supply volt-age correspond to that shown on the name plate?

The unit may malfunction or the components burn out.

Are wiring and piping cor-rect?

The unit may malfunction or the components burn out.

Is the unit safely grounded?Imcomplete grounding may result in electric shocks.

Is wiring size according to specifications?

The unit may malfunction or the components burn out.

26 pcs.

2 English

Page 5: INSTALLATION MANUAL - Daikin€¦ · INSTALLATION MANUAL FXDQ15A2VEB FXDQ20A2VEB FXDQ25A2VEB FXDQ32A2VEB FXDQ40A2VEB FXDQ50A2VEB FXDQ63A2VEB System Inverter Air Conditioners. CE -

Also review the “SAFETY PRECAUTIONS”.

b. Items to be checked at time of delivery

c. Points for explanation about operations

3. SELECTING INSTALLATION SITE

CAUTION

• When moving the unit during or after unpacking, make sure to lift it by holding its lifting lugs. Do not exert any pressure on other parts, especially the refrigerant piping, drain piping and flange parts.

• If you think the humidity inside the ceiling might exceed 30°C and RH80%, reinforce the insulation on the unit body.Use glass wool or polyethylene foam as insulation so that it is no thicker than 10mm and fits inside the ceiling open-ing.

(1) Select an installation site where the following conditions are fulfilled and that meets with your customer’s approval.• Where optimum air distribution can be ensured.• Where nothing blocks air passage.• Where condensate can be properly drained.• Where the ceiling is strong enough to bear the indoor unit

weight.• Where the false ceiling is not noticeably on an incline.• Where there is no risk of flammable gas leakage.• Where sufficient clearance for maintenance and service

can be ensured. (Refer to Fig. 1)• Where piping between indoor and outdoor units is possi-

ble within the allowable limit. (Refer to the installation manual for the outdoor unit.)

• The equipment is not intended for use in a potentially explosive atmosphere.

• *H1 dimension means the minimum height of the unit.• Select the *H1, *H2 dimension such that a downward

slope of at least 1/100 is ensured as indicated in “7. DRAIN PIPING WORK”.

• The maintenance space marked with “*” is required when the installation box for adaptor PC board (KRP1BA101) sold separately is used.

[ PRECAUTION ]• Install the indoor and outdoor units, power supply wiring

and connecting wires at least 1 m away from televisions or radios in order to prevent image interference or noise. (Depending on the radio waves, a distance of 1 m may not be sufficient enough to eliminate the noise.)

• If installing the wireless kit in a room with electronic fluo-rescent lighting (inverter or rapid start type), the remote controller’s transmission distance may be shortened. Indoor units should be installed as far away from fluores-cent lighting as possible.

(2) Use suspension bolts for installation. Check whether the ceiling is strong enough to support the weight of the unit or not. If there is a risk, reinforce the ceiling before installing the unit.

• To avoid contact with the fan, one of the following precaution actions must be taken:- Install the unit as high as possible at a minimum bottom

height of 2.7 m.- Install the unit as high as possible at a minimum bottom

height of 2.5 m in case the fan is externally screened by parts which can be removed without the aid of tools (e.g. false sealing, grill ... ).

- Install the unit with ducting and grill which can only be removed with the aid of tooling. It shall be installed so that it gives adequate protection against touching the fan. If a maintenance panel exists in the ducting, it shall only be possible to remove the panel by the aid of tooling to avoid contact with the fan. The protection shall be according to relevant European and local legislation. There are no restrictions concerning the installation height.

Is something blocking the air outlet or inlet of either the indoor or outdoor units?

It may result in insufficient cooling.

Are refrigerant piping length and additional refrigerant charge noted down?

The refrigerant charge in the system is not clear.

Items to be checked Check

Did you explain about operations while showing the operation manual to your customer?

Did you hand the operation manual and warranty over to your customer?

Did you explain about the way of maintaining and cleaning local procurements (air filter, grille (both air outlet and suc-tion grille), etc.) to your customer?

Did you hand manuals of local procurements (in case equipped) over to your customer?

The items with WARNING and CAUTION marks in the operation manual are the items pertaining to possibilities for bodily injury and material damage in addition to the general usage of the product. Accordingly, it is necessary that you make a full explanation about the described contents and also ask your customers to read the operation manual.

200

Fig. 1

(length : mm)

Floor surface

Ceiling

*H2=20 or more

*300 or more

300 or more

Maintenance space

Maintenance space

Control box

*H1=

24

0 or

mor

e

2500

or m

ore

English 3

Page 6: INSTALLATION MANUAL - Daikin€¦ · INSTALLATION MANUAL FXDQ15A2VEB FXDQ20A2VEB FXDQ25A2VEB FXDQ32A2VEB FXDQ40A2VEB FXDQ50A2VEB FXDQ63A2VEB System Inverter Air Conditioners. CE -

4. PREPARATIONS BEFORE INSTALLATION(1) Confirm the positional relationship between the unit

and suspension bolts. (Refer to Fig. 2)• Install the inspection opening on the control box side where

maintenance and inspection of the control box and drain pump are easy. Install the inspection opening also in the lower part of the unit.

(length: mm)

(2) Make sure the range of the unit’s external static pres-sure is not exceeded.(See the technical documentation for the range of the external static pressure setting.)

(3) Open the installation hole. (Pre-set ceilings)• Once the installation hole is opened in the ceiling where

the unit is to be installed, pass refrigerant piping, drain piping, transmission wiring, and remote controller wiring (It is not necessary if using a wireless remote controller) to the unit’s piping and wiring holes.See “6. REFRIGERANT PIPING WORK”, “7. DRAIN PIPING WORK”, and “10. WIRING EXAMPLE”.

• After opening the ceiling hole, make sure ceiling is level if needed. It might be necessary to reinforce the ceiling frame to prevent shaking.Consult an architect or carpenter for details.

(4) Install the suspension bolts. (Use W3/8 to M10 suspension bolts.)Use a hole-in-anchor for existing ceilings, and a sunken insert, sunken anchor or other part to be procured in the field to reinforce the ceiling to bearing the weight of the unit for new ceiling. (Refer to Fig. 3)

(5) In case of bottom suction(1) Remove the chamber lid. (7 locations)(2) Reattached the removed chamber lid in the orientation

shown in Fig. 4. (7 locations)(3) Attach the air filter (accessory) in the manner shown in

the diagram.The four holes which cannot be covered by the air filter should be covered with commercially available tape.

Model A B

15-20-25-32 type 750 740

40-50 type 950 940

63 type 1150 1140

BA

620

500

450×450

620

A

Drain pump

SERVICE SPACE

Fig. 2Inspection door

(Ceiling opening)

Allow view

Control box

Air inlet

(length : mm)Suspension bolt pitch

Air outlet

Ceiling

(Inspection opening size)

(Sus

pens

ion

bolt

pitc

h)

Fig. 3

Ceiling slab

Indoor unit

Anchor bolt

Long nut or turn-buckle

Suspension bolt

Note: All the above parts are field supplied.

(1)

(2)

Chamber lid

Chamber lid

Air discharge

Air inletAir discharge

Fig. 4

Air inlet

4 English

Page 7: INSTALLATION MANUAL - Daikin€¦ · INSTALLATION MANUAL FXDQ15A2VEB FXDQ20A2VEB FXDQ25A2VEB FXDQ32A2VEB FXDQ40A2VEB FXDQ50A2VEB FXDQ63A2VEB System Inverter Air Conditioners. CE -

5. INDOOR UNIT INSTALLATIONAs for the parts to be used for installation work, be sure to use the provided accessories and specified parts desig-nated by our company.

(1) Install the indoor unit temporarily.• Attach the hanger bracket to the suspension bolt. Be sure

to fix it securely by using a nut and washer from the upper and lower sides of the hanger bracket. (Refer to Fig. 5)

[ PRECAUTION ]Since the unit uses a plastic drain pan, prevent welding spatter and other foreign substances from the air outlet during installation.

(2) Adjust the height of the unit.

(3) Check the unit is horizontally level.

CAUTION

• Make sure the unit is installed level using a level or a plastic tube filled with water. In using a plastic tube instead of a level, adjust the top surface of the unit to the surface of the water at both ends of the plastic tube and adjust the unit horizontally. (One thing to watch out for in particular is if the unit is installed so that the slope is not in the direction of the drain piping, this might cause leak-ing.)

(4) Tighten the upper nut.

6. REFRIGERANT PIPING WORKFor refrigerant piping of outdoor units, see the installation manual attached to the outdoor unit.Execute heat insulation work completely on both sides of the gas piping and the liquid piping. Otherwise, a water leakage can result sometimes.Use insulation that can withstand temperatures of at least 120°C. Reinforce the insulation on the refrigerant piping according to the installation environment. If the tempera-ture above the ceiling might reach 30°C or the humidity RH80%. Condensation may form on the surface of the insu-lation.

CAUTION

Follow the points at below.• Use a pipe cutter and flare suitable for the type of refrigerant.• Apply ester oil or ether oil to the flare section when using a

flare connection.• Only use the flare nuts included with the unit. Using different

flare nuts may cause the refrigerant to leak.• To prevent dust, moisture or other foreign matter from infil-

trating the piping, either pinch the end or cover it with tape.• Do not allow anything other than the designated refrigerant

to get mixed into the refrigerant circuit, such as air, etc. If any refrigerant gas leaks while working on the unit, ventilate the room thoroughly right away.

(1) Connect the piping.• The outdoor unit is charged with refrigerant.• Be sure to use both a spanner and torque wrench together,

as shown in the drawing, when connecting or disconnecting pipes to/from the unit. (Refer to Fig. 6)

• Refer to the Table 1 for the dimensions of flare nut spaces.• Apply ester oil or ether oil to flare section (both inside and

out) when using flare nut connections and then turn 3 or 4 times by hand. (Refer to Fig. 7)

(3)

Attach the filter to the main unit while pushing down on the bends.

Main unit

Force

Force

Filter

In case of back sideIn case of bottom side

(accessory)

(accessory)

Washer fixing plate (11)

Insert below washer

Fig. 5

Tighten(double nut)

Hanger bracket

Washer for hanging bracket (8)

[ How to secure washers ][ Securing the hanger bracket ]

Part to be procured in the field

Level

Vinyl tube

Fig. 7Fig. 6

Flare nut

Piping union

Ester oil or ether oil

Spanner

Torque wrench

English 5

Page 8: INSTALLATION MANUAL - Daikin€¦ · INSTALLATION MANUAL FXDQ15A2VEB FXDQ20A2VEB FXDQ25A2VEB FXDQ32A2VEB FXDQ40A2VEB FXDQ50A2VEB FXDQ63A2VEB System Inverter Air Conditioners. CE -

• Refer to Table 1 for tightening torque.

Table 1

CAUTION

Overtightening may damage the flare and cause leaks.Be careful for oil not to adhere to any portions other than a flare part. If oil adhere to resin parts etc., there is a possibility of damaging by deterioration.

• Refer to Table 2 if no torque wrench is available.Using a wrench to tighten flare nuts causes the tightening torque to suddenly grow much tighter after a certain point.From there, tighten the nut further by the appropriate angle listed in Table 2.

(2) After the work is finished, make sure to check that there is no gas leak.

(3) After checking for gas leaks, be sure to insulate the pipe connections referring to Fig. 8.• Insulate using the insulation for fitting (3) (4) included with

the liquid and gas pipes. Besides, make sure the insula-tion for fitting (3) (4) on the liquid and gas piping has its seams facing up.(Tighten both edges with clamp (9).)

• For the gas piping, wrap the mid. sealing pad (6) over the insulation for fitting (4) (flare nut part).

CAUTION

Be sure to insulate any field piping all the way to the piping connection inside the unit. Any exposed piping may cause condensation or burns if touched.

• When brazing the refrigerant piping, perform nitrogen replacement first, or perform the brazing (CAUTION 2) while feeding nitrogen into the refrigerant piping (CAUTION 1), and finally connect the indoor unit using the flare connections. (Refer to Fig. 9)

CAUTION

1. When brazing a pipe while feeding nitrogen inside the pipe, make sure to set the nitrogen pressure to 0.02 MPa

(0.2 kg/cm2) using the pressure reducing valve. (This

pressure is such that breeze is blown to your cheek.)2. Do not use a flux when brazing the refrigerant pipe joints.

Use phosphor copper brazer (BCuP-2: JIS Z 3264/B-Cu93P-710/795: ISO 3677) which does not require flux. (Using a flux containing chlorine may cause the piping to corrode. Using a welding flux containing fluorine may cause the refrigerant lubricant to deteriorate, and affect adversely the refrigerant piping system.)

Not recommendable but in case of emergency

You must use a torque wrench but if you are obliged to install the unit without a torque wrench, you may follow the installation method mentioned below.

After the work is finished, make sure to check that there is no gas leak.

When you keep on tightening the flare nut with a spanner, there is a point where the tightening torque suddenly increases. From that position, further tighten the flare nut the angle shown below:

Table 2

Pipe size

Tightening torqueFlare dimen-sion A (mm)

Flare shape

φ 6.4 15 – 17 N·m 8.7 – 9.1

φ 9.5 33 – 39 N·m 12.8 – 13.2

φ 12.7 50 – 60 N·m 16.2 – 16.6

φ 15.9 63 – 75 N·m 19.3 – 19.7

A

450

20

R0.4-0.8

900

20

Main unit

Wrap over the top of the flare nut connection.

(accessory)

(accessory)

Insulation for fitting (3)(accessory)

Liquid pipe

Fig. 8

Main unit

Attach to base

Piping insulation material (main unit)

Piping insulation material(Field supply)

Turn seams up

Flare nut connection

Clamp (9) (accessory)

Piping insulation material(Field supply)

Clamp (9)(accessory)

Liquid Piping Insulation Procedure

Gas Piping Insulation Procedure

Insulation for fitting (4)

Mid. sealing pad (6)

Turn seams upFlare nut connection

Attach to base

Piping insulation material (main unit)

Gas pipe

Pipe size Further tightening angleRecommended arm length of tool

φ 6.4 (1/4”) 60 to 90 degrees Approx. 150mm

φ 9.5 (3/8”) 60 to 90 degrees Approx. 200mm

φ 12.7 (1/2”) 30 to 60 degrees Approx. 250mm

φ 15.9 (5/8”) 30 to 60 degrees Approx. 300mm

Fig. 9

Nitrogen

NitrogenHands valve

Pressure-reducing valve

TapingPart to be brazed

Refrigerant piping

6 English

Page 9: INSTALLATION MANUAL - Daikin€¦ · INSTALLATION MANUAL FXDQ15A2VEB FXDQ20A2VEB FXDQ25A2VEB FXDQ32A2VEB FXDQ40A2VEB FXDQ50A2VEB FXDQ63A2VEB System Inverter Air Conditioners. CE -

7. DRAIN PIPING WORK

CAUTION

• Make sure all water is out before making the duct connection.

(1) Install the drain piping.

• Make sure the drain works properly.• The diameter of the drain piping should be greater than or

equal to the diameter of the connecting pipe (vinyl tube; pipe size: 20 mm; outer dimension: 26 mm). (not including the riser)

• Keep the drain piping short and sloping downwards at a gra-dient of at least 1/100 to prevent air pockets from forming.(Refer to Fig. 10)

CAUTION

Water accumulating in the drain piping can cause the drain to clog.

• To keep the drain piping from sagging, space hanging bracket every 1 to 1.5 m.

• Use the drain hose (2) and the metal clamp (1). Insert the drain hose (2) fully into the drain socket and firmly tighten the metal clamp (1) with the upper part of the tape on the hose end. Tighten the metal clamp (1) until the screw head is less than 4 mm from the hose. (Refer to Fig. 11, 12)

• The two areas below should be insulated because conden-sation may form there causing water to leak.

• Drain piping passing indoors• Drain socket

Referring the figure below, insulate the metal clamp (1) and drain hose (2) using the included large sealing pad (5).(Refer to Fig. 12)

PRECAUTIONS FOR DRAIN RAISING PIPE • Make sure the drain raising pipe height is no higher than

600mm.• Place the drain raising pipe vertically and make sure it is no

further than 300mm from the unit. (Refer to Fig. 13)

PRECAUTIONS

Drain piping connections• Do not connect the drain piping directly to sewage pipes that

smell of ammonia. The ammonia in the sewage might enter the indoor unit through the drain piping and corrode the heat exchanger.

• Do not twist or bend the drain hose (2), so that excessive force is not applied to it. (This type of treatment may cause leaking.)

• If you are using central drain piping, follow the procedure outlined in the figure 10.

• Select central drain piping of proper size according to the capacity of the connected unit.

(2) After piping work is finished, check drainage flows smoothly, with manner described below.

CAUTION

• The electric wiring work shall be performed by qualified elec-tricians.

• If workers not having the electrician qualification have per-formed the electric wiring work, the steps 3 to 7 shall be per-formed after the TEST RUN.

(with rubber cap)Service drain hole

Refrigerant pipes

Drain socket

Central drain piping (with a slope of at least 1/100)

600m

m

or le

ss

Fig. 10

(accessory)

(accessory)Metal clamp (1)

Large sealing pad (5)

≤4mm(accessory)

(accessory)

Fig. 12Fig. 11

Tape Drain hose (2)

Metal clamp (1)

Locate the drain hose horizontally or with a little upward gradient.

If there is an air bank, noise may be generated as a result of a water backflow when the drain pump comes to a stop.

Horizontal or upward slope

Drain hose (2) (accessory)

Fig. 13

1 – 1.5m

(Field supply)

(600mm or less)Adjustable range

Hanging bracket300 mm or less

Ceiling slab

Drain hose (2) (accessory)

Metal clamp (1) (accessory)

Drain raising pipe

English 7

Page 10: INSTALLATION MANUAL - Daikin€¦ · INSTALLATION MANUAL FXDQ15A2VEB FXDQ20A2VEB FXDQ25A2VEB FXDQ32A2VEB FXDQ40A2VEB FXDQ50A2VEB FXDQ63A2VEB System Inverter Air Conditioners. CE -

1. Remove the control box lid. Connect the remote controller and power supply (single-phase, 50 Hz 220-240 V or sin-gle-phase, 60Hz 220V) respectively to the terminal block and securely connect the earth also (as shown in the figure below).

CAUTION

Securely clamp the cables with the clamps (9)(10) offered as accessories as shown in Fig. 17 so that tension will not be applied on the cable connection areas.

2. Confirm that the control box lid is closed before turning on the power.

3. Remove the inspection lid.4. Gradually pour approximately 1L of water from the inspec-

tion window into the drain pan to check drainage.

CAUTION

Be sure to prevent an external force from being exerted on the float switch. (This may cause breakage.)

5. Attach the inspection lid.6. Perform the following operation using the remote controller,

and check drainage.• Select the inspection/test operation button “ ” using

the remote controller. The unit will engage the test oper-ation. Press the operation selector button “ ”, and select FAN OPERATION “ ”.

• Press the ON/OFF button “ ”. (The indoor fan and drain pump will operate.)

CAUTION

The fan will turn also at the same time. Take due care.Do not touch the drain pump to prevent electric shock.

7. Make sure to use the remote controller in finishing the oper-ation.

8. INSTALLING THE DUCTConnect the duct supplied in the field.Air inlet side• Attach the duct and intake-side flange (field supply).• Connect the flange to the main unit with accessory screws

(7).

• Wrap the intake-side flange and duct connection area with aluminum tape or something similar to prevent air escaping.

CAUTION

When attaching a duct to the intake side, be sure to attach an air filter inside the air passage on the intake side. (Use an air filter whose dust collecting efficiency is at least 50% in a gravimetric technique.)The included filter is not used when the intake duct is attached.

Air outlet side• Connect the duct according to the air inside of the outlet-side

flange.• Wrap the outlet-side flange and the duct connection area

with aluminum tape or something similar to prevent air escaping.

CAUTION

• Be sure to insulate the duct to prevent condensation from forming. (Material: glass wool or polyethylene foam, 25 mm thick)

• Use electric insulation between the duct and the wall when using metal ducts to pass metal laths of the net or fence shape or metal plating into wooden buildings.

• Be sure to explain about the way of maintaining and cleaning local procurements (air filter, grille (both air outlet and suction grille), etc.) to your customer.

TEST

TRANSMISSIONWIRING

REMOTECNTRL

T1F1FORCED

OFF

P2 F2P1 T2

NL

L N

Power supply: Single phase, 50 Hz, 220 V–240VSingle phase, 60Hz, 220 VPower terminal connection method

Remote controller terminal connection method Terminal block Terminal block

Indoor PCboard (ASSY)

(with rubber cap)

Drain outlet

Service drain hole Bucket

Refrigerant pipesInspection lid

Portable pumpInspection window

Class 15 · 20 · 25 · 32 40 · 50 63

Number of positions

16 22 26

Air outlet sideAir inlet side

Insulation materialMain unit

Aluminum tape

Aluminum tape

Flange

Flange

(Field supply)

(Field supply)

(Field supply)

(Field supply)

(accessory)

Connection screw (7)

8 English

Page 11: INSTALLATION MANUAL - Daikin€¦ · INSTALLATION MANUAL FXDQ15A2VEB FXDQ20A2VEB FXDQ25A2VEB FXDQ32A2VEB FXDQ40A2VEB FXDQ50A2VEB FXDQ63A2VEB System Inverter Air Conditioners. CE -

9. ELECTRIC WIRING WORK

9-1 GENERAL INSTRUCTIONS• Shut off the power before doing any work.• All field supplied parts and materials, electric works must

conform to local codes.• Use copper wire only.• See also the “Wiring Diagram plate” attached to the control

box lid when laying electrical wiring.• For details on hooking up the remote controller, refer to the

“REMOTE CONTROLLER INSTALLATION MANUAL”.• All wiring must be performed by an authorized electrician.• This system consists of multiple indoor units. Mark each

indoor unit as unit A, unit B . . . , and be sure the terminal board wiring to the outdoor unit and BS unit are properly matched. If wiring and piping between the outdoor unit and an indoor unit are mismatched, the system may cause a malfunction.

• A circuit breaker capable of shutting down power supply to the entire system must be installed.

• Refer to the installation manual attached to the outdoor unit for the size of power supply wiring connected to the outdoor unit, the capacity of the circuit breaker and switch, and wiring instructions.

• Be sure to ground the air conditioner.• Do not the earth wire should come in contact with gas pipes,

water pipes, lightning rods, or telephone earth wires.• Gas pipes: gas leaks can cause explosions and fire.• Water pipes: they cannot be grounded if hard vinyl pipes

are used.• Telephone earth wire and lightning rods: the ground

potential when struck by lightning gets extremely high.• To avoid short circuiting the power supply wire, be sure to

use insulated terminals.• Do not turn on the power supply (circuit breaker or earth leak-

age breaker) until all other work is done.

9-2 SPECIFICATIONS FOR FIELD SUPPLIED FUSES AND WIRE

Power-related

NOTES1. Shows only in case of protected pipes. Use H07RN-F in

case of no protection.2. Insulated thickness : 1mm or more.3. If the wiring is in a place where people it can be easily

touched by people, install an earth leakage breaker to pre-vent electric shock.

4. When using an earth leakage breaker, make sure to select one useful also to protection against overcurrent and short-circuit.When using an earth leakage breaker only for earth device, make sure to use a wiring interrupter together.

• The length of the transmission wiring and remote controller wiring are as follows.

Length of the transmission wiring and remote controller wiring

9-3 ELECTRICAL CHARACTERISTICS

MCA: Minimum Circuit Amps (A) MFA:Max. Fuse Amps (A)KW: Fan motor output (kW) FLA:Full Load Amps (A)

Model

Power supply wiring (including earth wire)

Number of units

Field fuses Wire Size

15 · 20 · 25 · 32 type

1 16 AH05VV-U3G

(NOTE 1)

Size must comply with local codes.

40 · 50 type

63 type

Model

Transmission wiringRemote controller wiring

Wire Size (mm2)

15 · 20 · 25 · 32 typeSheathed vinyl cord or cable (2 wires) (NOTE 2)

0.75 - 1.2540 · 50 type

63 type

Outdoor unit – Indoor unitMax. 1000m

(Total wiring length: 2000m)

Indoor unit – Remote controller Max. 500m

Units Power supply Fan motor

Model Hz VoltsVoltage range

MCA MFA KW FLA

15 · 20 · 25 · 32

50220-240

Min. 198

Max. 264

0.4

16

0.036 0.3

40 0.5 0.038 0.4

50 0.5 0.038 0.4

63 0.6 0.060 0.5

15 · 20 · 25 · 32

60 220

Min. 198

Max. 242

0.4

16

0.036 0.3

40 0.5 0.038 0.4

50 0.5 0.038 0.4

63 0.6 0.060 0.5

English 9

Page 12: INSTALLATION MANUAL - Daikin€¦ · INSTALLATION MANUAL FXDQ15A2VEB FXDQ20A2VEB FXDQ25A2VEB FXDQ32A2VEB FXDQ40A2VEB FXDQ50A2VEB FXDQ63A2VEB System Inverter Air Conditioners. CE -

10. WIRING EXAMPLE10-1 HOW TO CONNECT WIRINGS • Wire only after removing the control box lid as shown in

Fig. 17, refering to view A.

CAUTION

• Be sure to attach power supply wiring and earth wire to the control box with the clamp.

• When doing the wiring, make sure the wiring is neat and does not cause the control box lid to stick up, then close the cover firmly. When attaching the control box lid, make sure you do not pinch any wires.

• Outside the air conditioners, separate the weak wiring (remote controller and transmission wiring) and strong wiring (earth wire and power supply wiring) at least 50 mm so that they do not pass through the same place together. Proximity may cause electrical interference, malfunctions, and break-age.

• A main switch or other means for disconnection, having a contact separation in all poles, must be incorporated in the fixed wiring in accordance with relevant local and national legislation.Note that the operation will restart automatically if the main power supply is turned off and then turned back on again.

[ PRECAUTIONS ] • Refer to the “REMOTE CONTROLLER INSTALLATION

MANUAL” on how to install and lay the wiring for the remote controller.

• See also the “Wiring Diagram plate” attached to the control box lid when laying electrical wiring.

• Connect the remote controller and transmission wiring their respective terminal blocks.

CAUTION

• Do not, under any circumstances, connect the power sup-ply wiring to the remote controller or transmission wiring terminal block. Doing so can destroy the entire system.

[ Connecting electrical wiring, remote controller wiring, and transmission wiring ] (Refer to Fig. 18)

• Power supply and Earth wiringRemove the control box lid.Next, pull the wires into the unit through the wiring through hole and connect to the terminal block (3P).Be sure to put the part of the sheathed vinyl into the control box.

(Rear)Wiring Diagram

Control box lid

Power supply wiringEarth wire

Penetration area

• Make sure to let a wire go through a wire penetration area.• After wiring, seal the wire and wire penetration area to prevent

moisture and small creatures from the outside.• Wrap the strong and weak electric lines with the sealing

material (12) as shown in the figure below. (Otherwise, moisture or small creatures such as insects from

the outside may cause short-circuit inside the control box.) Attach securely so that there are no gaps.

Sealing material (12)

(accessory)

Wire

[How to adhere it]

Outside unit

Inside unit

Fig. 17

view A

Power supply wiringEarth wire

Indoor PCboard (ASSY)

Clamps(for preventing slippage)

*Transmission wiring*Remote controller wiring* Do not connect power supply wiring here.That may cause malfunction

Control box Control box

Power supply wiring/Earth wire

Fig. 18

Remote controller wiringTransmission wiring

Power supply wiringEarth wire

Wiring through hole

Wiring through hole

Terminal block (6P)

Terminal block (3P)

Indoor PCboard (ASSY)

Clamps

P1 P2 F1 F2 T1 T2TRANSMISSION WIRING

FORCED OFF

REMOTE CNTRL

10 English

Page 13: INSTALLATION MANUAL - Daikin€¦ · INSTALLATION MANUAL FXDQ15A2VEB FXDQ20A2VEB FXDQ25A2VEB FXDQ32A2VEB FXDQ40A2VEB FXDQ50A2VEB FXDQ63A2VEB System Inverter Air Conditioners. CE -

• Remote controller and transmission wiringPull the wires into the unit through the wiring through hole and connect to the terminal block (6P).Be sure to put the part of the sheathed vinyl into the control box.

Precautions when laying power supply wiring • Wiring of different thicknesses cannot be connected to the

power supply wiring terminal block. (Slack in the power sup-ply wiring may cause abnormal heat.)

• Use sleeve-insulated round crimp-style terminals for connec-tions to the power supply wiring terminal block. When none are available, connect wires of the same diameter to both sides, as shown in the figure.

Follow the instructions are below if the wiring may get very hot due to slack in the power supply wiring.• For wiring, use the designated power supply wiring and con-

nect firmly, then secure to prevent outside pressure being exerted on the terminal board.

• Use the correct screwdriver for tightening the terminal screws. If the blade of screwdriver is too small, the head of the screw might be damaged, and the screw will not be prop-erly tightened.

• If the terminal screws are tightened too hard, screws might be damaged.

• Refer to the table below for the tightening torque of the termi-nal screws.

[ WIRING EXAMPLE ]

No. 1 system When using 1 remote controller for 1 indoor unit

No. 2 system For group control or use with 2 remote controllers

Terminal block Tightening torque (N·m)

Remote controller / transmission wiring terminal block (6P)

0.79 – 0.97

Power supply wiring terminal block (3P) 1.18 – 1.44

Insulation sleeve

Round crimp-style terminalElectric wire

Do not connect wires of different gauges.

Do not connect wires of the same gauge to one side.

Connect wires of the same gauge to both sides.

F T1L1

1

1

PP 2

P

N1 2

P

TF

2

F

P

F

1

2

2

2

P 1

N

2

P2F

IN/D

1

OUT/D

1

P

F

2

F

1

P

L

F

1 2 T

2

T 1 PP 21F2N FL 1 2 T T

P

L N L N L N

(option) (option) (option)

Fig. 19

Remote controllerRemote controllerRemote controller

Outdoor unit

Power supply single phase

50Hz 220-240V or single phase

60Hz 220V

Power supply single phase

50Hz 220-240V or single phase

60Hz 220V

Power supply single phase

50Hz 220-240V or single phase

60Hz 220V

Most downstream indoor unit

Indoor unit BIndoor unit A

L N

1P 2P1P 2P1P 2P

1 PP 21F2N FL NL1 2

FF1 2 FF1 2

T T 1 PP 21F2 F 1 2 T T NL 1 PP 21F2 F 1 2 T T

IN/D OUT/D

Power supply single phase

50Hz 220-240V or single phase

60Hz 220V

(option) (option) Remote controllerRemote controller Remote controller

Fig. 20

Case of group control

For use with 2 remote controllers

Most downstream indoor unit

Indoor unit BIndoor unit A

Note) There is not need to set the indoor unit address when using group control. (It is automatically set when the power is turned on.)

Outdoor unit

English 11

Page 14: INSTALLATION MANUAL - Daikin€¦ · INSTALLATION MANUAL FXDQ15A2VEB FXDQ20A2VEB FXDQ25A2VEB FXDQ32A2VEB FXDQ40A2VEB FXDQ50A2VEB FXDQ63A2VEB System Inverter Air Conditioners. CE -

No. 3 system When including BS unit 10-2 CONTROL BY 2 REMOTE CONTROLLERS (Con-trolling 1 indoor unit by 2 remote controllers)

• When using 2 remote controllers, one must be set to “MAIN” and the other to “SUB”.

MAIN/SUB CHANGEOVER

(1) Insert a screwdriver into the recess between the upper and lower part of remote controller and, working from the 2 positions, pry off the upper part (2 loca-tions).The remote controller PC board is attached to the upper part of remote controller.

(2) Turn the MAIN/SUB changeover switch on one of the two remote controller PC boards to “S”.(Leave the switch of the other remote controller set to “M”.)

Wiring Method (See ‘‘9. ELECTRIC WIRING WORK’’)

(3) Remove the control box lid.

(4) Add remote controller 2 (SUB) to the terminal block for remote controller (P1, P2) in the control box.

(There is no polarity.)

L N

FF1 2 FF1 2 FF1 2 FF1 2

IN/D IN/DOUT/D OUT/D

1 PP 21F2N FL 1 2 T T

1P 2P

Power supply single phase

50Hz 220-240V or single phase

60Hz 220V

Fig. 21

Remote controller(option)

Indoor unit A

BS unitOutdoor unit

Upper part of remote controller

Lower part of remote controller

Insert the screwdriver here and gently work off the upper part of remote controller.

Only one remote controller needs to be changed if factory settings have remained untouched.

(Factory setting)S

MS

SM

Remote controller PC board

1P 2P 1F 2F 1T 2TFORCED

OFFREMOTECONTRL

TRANSMISSIONWIRING

Remote controller 1 (MAIN)

Remote controller 2 (SUB)

Remote controller wiring terminal block

12 English

Page 15: INSTALLATION MANUAL - Daikin€¦ · INSTALLATION MANUAL FXDQ15A2VEB FXDQ20A2VEB FXDQ25A2VEB FXDQ32A2VEB FXDQ40A2VEB FXDQ50A2VEB FXDQ63A2VEB System Inverter Air Conditioners. CE -

[ PRECAUTIONS ]• Crossover wiring is needed when using group control and

2 remote controllers at the same time. • Connect the indoor unit at the end of the crossover wire

(P1, P2) to remote controller 2 (SUB).

10-3 REMOTE CONTROL (FORCED OFF AND ON/OFF OPERATION)

• Connect input lines from the outside to the terminals T1

and T2 on the terminal block (6P) for remote controller to

achieve remote control.• See the “11. FIELD SETTING AND TEST RUN” for

details on operation.

10-4 CENTRALIZED CONTROL • For centralized control, it is necessary to designate the group

No. For details, refer to the manual of each optional control-lers for centralized control.

11. FIELD SETTING AND TEST RUNField settings may have to be performed using the remote controller, depending on the type of installation.(1) Make sure the control box lids are closed on the indoor

and outdoor units.

(2) Depending on the type of installation, make the field settings from the remote controller after the power is turned on, following the “Field Settings” manual which came with the remote controller.• The settings can select “Mode No.”, “FIRST CODE NO.”

and “SECOND CODE NO.”.• The “Field Settings” included with the remote controller

lists the order of the settings and method of operation.

• Lastly, make sure the customer keeps the “Field Settings” manual, along with the operating manual, in a safe place.

11-1 SETTING THE STATIC PRESSURE SELECTION• Select the SECOND CODE NO. for the resistance of the con-

nected duct. (The SECOND CODE NO. is set to “01” when shipped.)

• See the technical documentation for details.

11-2 REMOTE CONTROL SETTING• Forced off and ON/OFF operation should be selected by

selecting the SECOND CODE NO. as shown in the table below.(The SECOND CODE NO. is set to “01” when shipped.)

• Input A of forced off and ON/OFF operation work as shown in the table below.

11-3 SETTING THE FILTER SIGN DISPLAY INTERVAL• Explain the following to the customer if the filter dirt settings

have been changed.• The filter sign display time is set to 2500 hours

(equivalent to 1 year’s use) when shipped.• The settings can be changed to not display.• When installing the unit in a place with much dusts, set the fil-

ter sign display time to shorter intervals (1,250 hours).• Explain it to the customer that the filter needs to be cleaned

regularly to prevent clogging and also the time that is set.

Wire specification Sheathed vinyl cord or cable (2 wires)

Gauge 0.75 - 1.25 mm2

Length Max. 100 m

External terminalContact that can ensure the minimum applica-ble load of 15 V DC, 1 mA.

Remote controller 2 (SUB)

Remote controller 1 (MAIN)

Crossover wire (P1.P2)

Max. No. of indoor unitsIndoor unit 2Indoor unit 1

1P 2P 1F 2F 1T 2TFORCED

OFFREMOTECONTRL

TRANSMISSIONWIRING

Input A

SETTING

Mode No.

SECOND CODE NO.

FIELD SET MODE

FIRST CODE NO.

External static pressure

Mode No.FIRST

CODE NO.SECOND

CODE NO.

Standard (10Pa)

13(23) 5

01

High static pres-sure setting (30Pa)

02

External ON/OFF input Mode No.FIRST

CODE NO.SECOND

CODE NO.

Forced off12(22) 1

01

ON/OFF operation 02

Forced off ON/OFF operation

Input A “on” to force a stop (remote controller reception prohibited)

Unit operated by changing input A from “off” to “on”

Input A “off” to allow remote controllerUnit stopped by changing input A from “on” to “off”

Mode No. FIRST CODE NO.SECOND CODE NO.

01 02

10 (20)

0 Filter dirt low high

1 (low/high)Displayed time(units: hours)

2500/1250

10000/5000

3Filter sign

displayON OFF

English 13

Page 16: INSTALLATION MANUAL - Daikin€¦ · INSTALLATION MANUAL FXDQ15A2VEB FXDQ20A2VEB FXDQ25A2VEB FXDQ32A2VEB FXDQ40A2VEB FXDQ50A2VEB FXDQ63A2VEB System Inverter Air Conditioners. CE -

11-4 SETTINGS FOR SEPARATELY SOLD ACCESSORIES

• See the instruction manuals included with separately sold accessories for the necessary settings.

When using a wireless remote controller • A wireless remote controller address needs to be set when

using a wireless remote controller. See the installation man-ual included with the wireless remote controller for details on how to make the settings.

(3) Perform a test run according to the outdoor unit’s installation manual.• The operation lamp of the remote controller will flash

when a malfunction occurs. Check the malfunction code on the liquid crystal display to identify the point of trouble. An explanation of malfunction codes and the correspond-ing trouble is provided in “CAUTION FOR SERVICING” of the outdoor unit.If the display shows any of the following, there is a possi-bility that the wiring was done incorrectly or that the power is not on, so check again.

CAUTION

• Always stop the test run using the remote controller to stop operation.

(4) After finishing the test run, make sure to check drain-age in the drain pump according to “7. DRAIN PIPING WORK”.

Remote control display Content

“ ” display• There is a short circuit at the FORCED

OFF terminals (T1, T2).

“ ” display • The test-run has not been performed.

“ ” display

“ ” display

• The power on the outdoor unit is off.• The outdoor unit has not been wired for

power supply.• Wiring is incorrect for the transmission

wiring and / or FORCED OFF wiring.• The transmission wiring is cut.

“ ” display • Reversed transmission wiring

No display

• The power on the indoor unit is off.• The indoor unit has not been wired for

power supply.• Wiring is incorrect for the remote con-

troller wiring, the transmission wiring and / or the FORCED OFF wiring.

• The remote controller wiring is cut.

14 English

Page 17: INSTALLATION MANUAL - Daikin€¦ · INSTALLATION MANUAL FXDQ15A2VEB FXDQ20A2VEB FXDQ25A2VEB FXDQ32A2VEB FXDQ40A2VEB FXDQ50A2VEB FXDQ63A2VEB System Inverter Air Conditioners. CE -

12. WIRING DIAGRAM

INDOOR UNIT

A1P.........................PRINTED CIRCUIT BOARD

C105.......................CAPACITOR

PS...........................POWER SUPPLY CIRCUIT

F1U.........................FUSE (T, 3,15A, 250V)

F2U.........................FIELD FUSE

HAP........................LIGHT EMITTING DIODE (SERVICE MONITORING –GREEN)

M1F ........................MOTOR (FAN)

M1P........................MOTOR (DRAIN PUMP)

Q1DI .......................EARTH LEAK DETECTOR

R1T.........................THERMISTOR (AIR)

R2T, R3T ................THERMISTOR (COIL)

S1L .........................FLOAT SWITCH

V1R ........................DIODE BRIDGE

X1M........................TERMINAL BLOCK (CONTROL)

X2M........................TERMINAL BLOCK (POWER SUPPLY)

Y1E.........................ELECTRONIC EXPANSION VALVE

Z1F.........................NOISE FILTER

Z1C.........................FERRITE CORE (NOISE FILTER)

RECEIVER/DISPLAY UNIT

A2P ........................PRINTED CIRCUIT BOARD

A3P ........................PRINTED CIRCUIT BOARD

BS1 ........................PUSH BUTTON (ON/OFF)

H1P........................ LIGHT EMITTING DIODE (ON-RED)

H2P........................ LIGHT EMITTING DIODE (FILTER DING-RED)

H3P........................ LIGHT EMITTING DIODE (TIMER-GREEN)

H4P........................ LIGHT EMITTING DIODE (DEFROST-ORANGE)

SS1 ........................SELECTOR SWITCH (MAIN/SUB)

SS2 ........................SELECTOR SWITCH (WIRELESS ADRESS SET)

ADAPTOR FOR WIRING

KHuR .....................MAGNETIC RELAY

KFR........................MAGNETIC RELAY

KCR .......................MAGNETIC RELAY

F3U, F4U ...............FUSE ( (B), 5A, 250V)

CONNECTOR FOR OPTIONAL PARTS

X24A ......................CONNECTOR (WIRELESSREMOTE CONTROLLER)

X33A ......................CONNECTOR (ADAPTOR FOR WIRING)

X35A ......................CONNECTOR (POWER SUPPLY CONNECTOR)

X38A ......................CONNECTOR (MULTI TENANT)

WIRED REMOTE CONTROLLER

R1T ........................THERMISTOR (AIR)

SS1 ........................SELECTOR SWITCH (MAIN/SUB)

: FIELD WIRING BLK : BLACK PRP : PURPLE

: CONNECTOR BLU : BLUE RED : RED

: WIRE CLAMP BRN : BROWN WHT : WHITE

: PROTECTIVE EARTH (SCREW) GRY : GREY YLW : YELLOW

L : LIVE ORG : ORANGE GRN : GREEN

N : NEUTRAL PNK : PINK

WIRED REMOTE CONTROLLER : Wired remote controller

(OPTIONAL ACCESSORY) : (Optional accessory)

SWITCH BOX (INDOOR) : Switch box (indoor)

TRANSMISSION WIRING : Transmission wiring

CENTRAL REMOTE CONTROLLER : Central remote controller

INPUT FROM OUTSIDE : Input from outside

NOTE 1. USE COPPER CONDUCTORS ONLY.

2. WHEN USING THE CENTRAL REMOTE CONTROLLER, SEE MANUAL FOR CONNECTION TO THE UNIT.

3. WHEN CONNECTING THE INPUT WIRES FROM OUTSIDE, FORCED "OFF" OR "ON/OFF" CONTROL OPERATION CANBE SELECTED BY THE REMOTE CONTROLLER. SEE INSTALLATION MANUAL FOR MORE DETAILS.

4. REMOTE CONTROLLER MODEL VARIES ACCORDING TO THE COMBINATION SYSTEM, CONFIRM ENGINEERINGDATA AND CATALOGS, ETC. BEFORE CONNECTING.

English 15

Page 18: INSTALLATION MANUAL - Daikin€¦ · INSTALLATION MANUAL FXDQ15A2VEB FXDQ20A2VEB FXDQ25A2VEB FXDQ32A2VEB FXDQ40A2VEB FXDQ50A2VEB FXDQ63A2VEB System Inverter Air Conditioners. CE -
Page 19: INSTALLATION MANUAL - Daikin€¦ · INSTALLATION MANUAL FXDQ15A2VEB FXDQ20A2VEB FXDQ25A2VEB FXDQ32A2VEB FXDQ40A2VEB FXDQ50A2VEB FXDQ63A2VEB System Inverter Air Conditioners. CE -
Page 20: INSTALLATION MANUAL - Daikin€¦ · INSTALLATION MANUAL FXDQ15A2VEB FXDQ20A2VEB FXDQ25A2VEB FXDQ32A2VEB FXDQ40A2VEB FXDQ50A2VEB FXDQ63A2VEB System Inverter Air Conditioners. CE -

4P325876-1 2012.07

Cop

yrig

ht 2

012

Dai

kin