Technical Publication
1
Related Support and Learning Opportunities Offered by the CommScope Infrastructure Academy
The insights and expertise contained in this manual represent just one small part of CommScope's global learning initiative. Few industries are evolving as quickly as wireless communications. Every technological innovation impacts what happens in the field. Our customers look to the CommScope Infrastructure Academy to make sure their technicians and installers are well trained, well-prepared, and well-educated to take advantage of opportunities as they evolve. To access a course, go to www.commscopetraining.com/coursecatalog.php, course #6107
Field Engineering Services (FES)
Support services, such as our Field Engineering Services (FES) Group gives CommScope customers access to technical support where and when it is needed the most — in the field. The FES team is staffed by an expert team of technicians who, in turn, are supported by some of the brightest and most experienced product line managers.
Section 1: Direct Breakout Components / Accessories ………...…………….......…………………………….…02
Section 2: Color Coding ...................................................................………………………………………..………03
Section 3: Hoisting Considerations .................................................………………………………………..………04
Section 4: DCM-U Mounting .............................….............................................................…………………....…06
Section 5: All-in-One Cleaner / Inspecting .....….............................................................…………………....…07
Section 6:General Specifications Fibre Tails ........……..............……………………….……....……………….....08
Section 7: DFJ-4S112B Fibre Tail Installation .......……..............……………………….……....……………….....09
Section 8: DFJ-4S114B Fibre Tail Installation .....……..............……………………….……....……………….....12
Section 9: DFJ-4S113B Fibre Tail Installation .....……..............……………………….……....……………….....15
Section 10: Excess Cable Management ......................................................…………….…….……………..……17
Section 11: MPO Installation / Wiring ..................................................………………………………………….....18
Section 12: Jacketing Removal Procedure / Reel Packaging ..................................………………..……..……20
Section 13: Installation Check List ................................................................................………………..……..……21
For more information, Contact Customer Service Center
Australia Tel 03 9300 7969 or Toll Free on 1800 803 219
United States and Mexico 1-800-255-1479 or 1-888-235-5732
International: +1-779-435-8579
For the most current, up-to-date information on all our products and product information please visit our eCatalog section at www.commscope.com.
Installation Guidelines – HELIAX® FiberFeed® Direct Solution: Direct Connect Bird Resistant Solution
Visit www.commscope.com for complete specifications on all the products listed Bulletin # 7693902 Rev. J
Technical Publication
2
Cable Series FDH808, 1208, 1810
FDH810, 1210
FDH1808
Bird proof Tails / Power conductors
FDH808, 1208, 1810
FDH810, 1210 FDH1808
DFJ-4S114B
All All
Part Number42396A-5
42396A-9
FA-3236-STH
FA-1923-STH
19256B-C
29958-C
29961-C
FA-BPB-NOK
243684 FA-102997-HC3
DescriptionStandard Hanger
Standard Hanger
Standard Hanger
Standard Hanger with grommet
Hoisting Grip (lace-up) Mounting bracket
Angle Adapter, compact 3/8 in tapped hole Cable entry seal, 24 - 54 mm (0.945 - 2.126 in) entry panel port size 4 in
Section 1: HELIAX® FiberFeed® Direct Components
!WARNING: CommScope Hybrid FiberFeed cables
require the use of approved installation accessories.
Direct Breakout canisters
Fibre tail
Equipment cabinet / shelter
Hybrid FiberFeed
Cable
Separate Fibre and
power conductors Maximum hanger spacing
0.9 m (3 ft) - 1.2 m (4 ft)
Mounting Kit Included Part Number: DCM-U
(additional components may be required based on installation configuration)
Minimum Distance 0.5 m (1.6 ft)
Supports up to 9 RRU's (Fibre and Power tails to 4 RRU shown for clarity)
Accessories
RRU
Power conductorsPower tail
Visit www.commscope.com for complete specifications on all the products listed Bulletin # 7693902 Rev. J
Technical Publication
3
Section 2: Color Coding
12233445
123
166778899 5
123456789
456789
789
44566778899 5
778899
123456
789
789
Fibre End 1 RRU
Power
End 1 Color End 2 Color1 RED
1 RED2 GREEN3 BLUE4 YELLOW
2 GREEN5 WHITE6 BLACK7 RED (X2)
3 BLUE8 GREEN (X2)9 BLUE (X2)
End 2 BBU
End 1 Label Color End 2 Conductor Color Label Color
1 RED1 Black w/ Blue stripe RED1 Red w/ Blue stripe RED
2 GREEN2 Black w/ Violet stripe GREEN2 Red w/ Violet stripe GREEN
3 BLUE3 Black w/ Green stripe BLUE3 Red w/ Green stripe BLUE
4 RED (X2)4 Black w/ Brown stripe RED (X2)4 Red w/ Brown stripe RED (X2)
5 GREEN (X2)5 Black w/ Yellow stripe GREEN (X2)5 Red w/ Yellow stripe GREEN (X2)
6 BLUE (X2)6 Black w/ White stripe BLUE (X2)6 Red w/ White stripe BLUE (X2)
7 RED (X3)7 Black w/ Red stripe RED (X3)7 Red w/ No stripe RED (X3)
8 GREEN (X3)8 Black w/ No stripe GREEN (X3)8 Red w/ Black stripe GREEN (X3)
9 BLUE (X3)9 Black w/ Gray stripe BLUE (X3)9 Red w/ Gray stripe BLUE (X3)
Visit www.commscope.com for complete specifications on all the products listed Bulletin # 7693902 Rev. J
Technical Publication
4
Section 3: Hoisting Considerations
Hoisting Recommendations
Reminder: Plan grip location by measuring distance (D) from ODC
compatible connector to tower support member.
(D)
(D)
Direct Breakout
Grip Location
• In general this cable will handle similarly to coaxial cable, and similar installation techniques apply. All cables are individually serialized, be sure to write down the cable serial number for future reference.
• Leave the protective sock around the Fibre tails and power conductors during hoisting and securing the cable.
• Be sure that the Direct breakout is not damaged by attachment of a hoisting grip or during the hoisting process. Attach a hoisting grip on the jacketed cable no less than .3 m (1 ft) below the Fibre breakout point. Prevent the Fibre tails and power conductors from undue movement during hoisting by securing the protective sock with tie ropes every 1 m (3 ft) to the hoisting line.
• During hoisting ensure that there is a free path and that the cable, and especially the end of the pulling sock will not be snagged on tower members or other obstacles.
• Installation temperature range is -40°C to +80°C (40°F to +176°F).
• Minimum cable bend radii can be found on-line in our eCatalog section at www.commscope.com/andrew.
• Maximum cable tensile load can be found on-line in our eCatalog section at www.commscope.com/andrew.
• CommScope Lace-Up Hoisting Grip 19256B-C required for 808, 1208, and 1810 installations.
• CommScope Lace-Up Hoisting Grip 29958-C required for 810 and 1210 installations.
• CommScope Lace-Up Hoisting Grip 29961-C required for 1808 installations.
• Hoisting Grip should be anchored to the support structure after the hangers are installed.
• During final connections to RRU, do not bend the Fibre ends tighter than 30 mm (1.2 in) bend radius or you take the risk of breaking the glass Fibres.
Hybrid Fibre Cables weigh more than traditional coaxial cables. Be sure to follow proper hoisting and attachment procedures.
!
4-Fibre ODC compatible connectors
Visit www.commscope.com for complete specifications on all the products listed Bulletin # 7693902 Rev. J
Technical Publication
5
Required Apply provided Tie Wrap to the base of
the hoisting grip before applying tension to
the line.
!
Clevis
Steel cable or rope
hoist line
Hoisting grip
Max
imum
60
m (2
00 ft
) be
twee
n ho
istin
g gr
ips
Hoisting Considerations
Tie back ropes 1 m (3 ft)
Visit www.commscope.com for complete specifications on all the products listed Bulletin # 7693902 Rev. J
Technical Publication
6
Section 4: DCM-U Mounting
Side View Top View
Angle adapter (UA-3)
Hose Clamp
Hardware
Stand Off
To Canister
Steel supportside view
Pipe mountside view
To Structure
Angle Adapter and Hose Clamp
Angle Adapter
Additional Hose Clamp (based on pipe dia.)
Insert (UAAI)
Visit www.commscope.com for complete specifications on all the products listed Bulletin # 7693902 Rev. J
Technical Publication
7
Device designed for cleaning the ferrule end faces of Fibre connectors
Open guide cap, insert connector into guide, push the outer shell to start cleaning the connector interface, a "click" sound indicates end of a cleaning process, repeat, close cap immediately after use.
Caution: Be careful not to slant connector while inserting into the Guide cap. Do not overly exert force during insertion as this may cause damage to both the connector and the cleaner.
Section 5: All in one cleaner
GuideConnector
Push Cleaner X2
Cap
There are 3 basic principles that are critical to achieving an efficient Fibre optic connection:
1. Perfect Core Alignment
2. Physical Contact
3. Pristine Connector Interface
Today’s connector design and production techniques have eliminated most of the challenges to achieving core alignment and physical contact. What remains challenging is maintaining a pristine end-face. As a result, CONTAMINATION is the #1 reason for troubleshooting optical networks.
Implementing the process of cleaning and inspecting before mating can reduce the time spent troubleshooting, optimize signal performance and prevent damage.
Inspecting
Is It Clean?
No ConnectYes
Inspect
Clean
Clean
Abrasive particles (i.e. rock dust) can cause permanent damage to the
interface. If interface is scratched it cannot be repaired, it would need to be replaced.
!
Scan to view video
Part Number Description
FCCT – MPO MPO Connectors
FCCT – ODC ODC compatible connector
FCCT – L DLC Connectors
Part Number: FCCT - L (shown)
Visit www.commscope.com for complete specifications on all the products listed Bulletin # 7693902 Rev. J
Technical Publication
8
HELIAX® FiberFeed®
Bend insensitive single mode Fibre (G.657.A2) Black DLCODC compatible (IP68)
37.1 kg/km | 24.9 lb/kft21 mm | .8 in
9 cm | 3.5 in 6 cm | 2.4 in 334 N | 75 lbf1110 N | 250 lbf
Section 6: General Specifications Fibre Tails
• The terminated Fibre ends however are fragile and must be protection during installation. Leave the packaging around the Fibre ends in place until ready to make final connect of the jumper at the RRU or BBU.
• DO NOT BEND THE Fibre ENDS TIGHTER THAN 30 mm (1.2 in) BEND RADIUS ELSE THERE IS A RISK OF BREAKING THE GLASS FibreS.
• Attach the main cable securely to the structure or equipment using hangers to prevent strain on connections from movement in wind or snow/ice conditions.
• Ensure the Fibre and power connections and seated firmly in the RRU.
• Installation temperature range is -40°C to +80°C (40°F to +176°F).
• All tails are individually serialized, for immediate access to test results visit www.commscope.com/webtrak/
General Specifications BrandFibre Type Jacket Color Interface: End 1Interface: End 2
Dimensions Cable Weight Diametre Over Bird Proofing
Physical Specifications Minimum Bend Radius, loaded Minimum Bend Radius, unloaded Tensile Load, long term, maximum Tensile Load, short term, maximum
HuaweiPART NUMBER DESCRIPTION
DFJ-4S112B-xxM 4 SM Fibre, breakout for Huawei RRU
NokiaPART NUMBER DESCRIPTION
DFJ-4S114B-xxM 4 SM Fibre, breakout for Nokia 4 Port RRU
NokiaPART NUMBER DESCRIPTION
DFJ-4S113B-xxM 4 SM Fibre, breakout for Nokia 6 Port RRU
Visit www.commscope.com for complete specifications on all the products listed Bulletin # 7693902 Rev. J
Technical Publication
9
Section 7: Fibre Tail Installation DFJ-4S112B
+ -
+ -+ -+ -
1
2
3
Tighten the ODC compatible connectors to 1 N•m (8.8 in−lb).
Slide protective sleeve over the connectors and onto the protective sleeve .
Tighten both ends of the protective sleeve.
75 mm(2.95 in)
+ -
Corrugated sleeve
Gland Nut
4 Place gland nut on edge of RRU. Connect the Fibre to the RRU then tighten the RRU clamp on corrugated sleeve over Fibre subunit.
Visit www.commscope.com for complete specifications on all the products listed Bulletin # 7693902 Rev. J
Technical Publication
10
For RRUs 3832, 3936, 3260 and 3268 slide 11 mm conduit inside of power tail bird resistant sleeve. Replace bird resistant connector by sliding connector over cable while twisting clockwise. Tighten the gland nut on the power cable.
Power Tail Installation to RRU
After the trunk cable is mounted measure distance to determine the length of the bird resistant sleeve and power conductor.
Remove bird resistant connector by loosening the gland nut. Open the safety clip with a screwdriver. Pull the connector off the bird resistant sleeve. Push the safety clip back into the connector.
X
X
2
1
3 4
Cut bird resistant sleeve at . Be careful not to cut the power conductor inside of the bird resistant sleeve. Dispose of excess bird resistant sleeve.
X
X
For RRUs 3832, 3936, 3260 and 3268 cut the power conductor to 200 mm (7.78 in). Dispose of excess power conductor.
1
2
12
200 mm (7.78 in)
1
24
3
1 2
3 4a 4b
5
For RRUs 3256 and 3929 cut the power conductor to 125 mm (4.92 in). Dispose of excess power conductor.
125 mm (4.92 in)
Remove the jacketing to expose the blue/black conductors.
6a
Visit www.commscope.com for complete specifications on all the products listed Bulletin # 7693902 Rev. J
Technical Publication
11
Feed power conductor into power box. Prep cable to dimensions listed on cover. Wire RRU and close lid. Cable gland needs to be flush with the bottom of the power box. Close door, install locking screws.
FibrePower
RRU
+ -+ GND -
8
For RRUs 3256 and 3929 remove 75 mm of length from the 11 mm conduit then slide the conduit inside of power tail bird resistant sleeve. Replace bird resistant connector by sliding connector over cable while twisting clockwise. Tighten the gland nut on the power cable.
1
2
1
2
6b 7 Place tape at end of conduit to build up thickness with for proper clamp seal
6X!
If jumper breakouts require staggering, install additional provided piece of bird resistant sleeve to cover both jumpers between the RRU and lower grommet. Close door, install locking screws.
Additional bird resistant sleeve (42 mm dia. 80 mm length)
RRU
+ -
Visit www.commscope.com for complete specifications on all the products listed Bulletin # 7693902 Rev. J
Technical Publication
12
Section 8: Fibre Tail Installation DFJ-4S114B
1
2
Slide protective sleeve of trunk Fibre tail.
Tighten the ODC compatible connectors to 1 N•m (8.8 in−lb).
3 Slide protective sleeve over the ODC compatible connectors and tighten both ends.
4 Remove top plate of the mounting bracket and mount to the RRU mounting plate. The screw and nut are fixed to the bracket.
5 Connect DLC connectors and install the weather seal boots.
RRU Mount
Mounting bracket
RRU
Fibre Ports
Mounting hardware
Part Number: FA-BPB-NOK
Visit www.commscope.com for complete specifications on all the products listed Bulletin # 7693902 Rev. J
Technical Publication
13
6 Slide bird resistant sleeve to cover Fibre boot.
Tighten protective sleeves to the jumper sleeves.
Reinstall top plate of the mounting bracket7
8
Power Tail Installation to RRU
After the trunk cable is mounted measure distance to determine the length of the bird proofing and power conductor.
Remove bird resistant connector by loosening the gland nut. Open the safety clip with a screwdriver. Pull the connector off the bird resistant sleeve. Push the safety clip back into the connector.
X
X
2
1
3 4
1
24
3
1 2
Visit www.commscope.com for complete specifications on all the products listed Bulletin # 7693902 Rev. J
Technical Publication
14
Slide the protective sleeve and power weatherproofing boot over power cable. Connect the power conductors to the RRU and slide the power weatherproofing boot into place.
Cut bird resistant sleeve at . Be careful not to cut the power conductor inside of the bird proofing. Dispose of excess bird resistant sleeve.
X
X
Cut the power conductor to 170 mm (6.69 in). Dispose of excess power conductor.
170 mm (6.69 in)
3 4
5 Replace bird resistant connector by sliding connector over cable while twisting clockwise. Tighten the gland nut on the power cable.
1
1
2
2
6
Slide the protective sleeve over the power weatherproofing boot. Connect aluminum bracket to the RRU with screw provided.
7 Connect the power conductors to the RRU and slide the power weatherproofing boot into place.
8
+ -+ GND -
Visit www.commscope.com for complete specifications on all the products listed Bulletin # 7693902 Rev. J
Technical Publication
15
Section 9: Fibre Tail Installation DFJ-4S113B
1
2
3
Tighten the ODC compatible connectors to 1 N•m (8.8 in−lb).
Slide protective sleeve over the connectors and onto the protective sleeve.
Tighten both ends of the protective sleeve.
75 mm(2.95 in)
4 Route Fibre to RRU, connect and lock gland on the RRU entry plate before installing cover. Entry plat will sit on the threaded portion of the gland nut.
Visit www.commscope.com for complete specifications on all the products listed Bulletin # 7693902 Rev. J
Technical Publication
16
Power Tail Installation to RRU
After the trunk cable is mounted measure distance to determine the length of the bird resistant sleeve and power conductor.
Remove bird resistant connector by loosening the gland nut. Open the safety clip with a screwdriver. Pull the connector off the bird resistant sleeve. Push the safety clip back into the connector.
X
X
2
1
3 4
Cut bird resistant sleeve at . Be careful not to cut the power conductor inside of the bird proofing. Dispose of excess bird proofing.
X
X
1
24
3
1 2
3 4
5
Replace bird resistant connector by sliding connector over cable while twisting clockwise. Tighten the gland nut on the power cable.
1
1
2
2
Route power to RRU, Connect and lock gland on the RRU entry plate before installing cover. Entry plate will sit on the threaded portion of the gland nut.
+ -+ GND -
Fibre
Power
Visit www.commscope.com for complete specifications on all the products listed Bulletin # 7693902 Rev. J
Technical Publication
17
Section 10: Excess Cable ManagementIf length of cable installed needs to be adjusted you can split the cable at the BBU end using the process below and then coiling the excess Fibre subunits in a storage box. Patch Panel Kits are available to manage any excess Fibre length in the breakouts at the BBU.
Mark cutback length Notch Armor using flush cutter in-line with Kevlar strings
Place Rip Cord in Notches Pull Rip Cord Parallel to Cable (while supporting breakout)
Stop at Length Marker Separate Armor
Cut Armor Using Side Cutter Remove Water Blocking Tape
Remove Excess Rip Cord Apply Electrical Tape to Protect Breakout
Patch Panel Kit Part Number:
HFF-SMPK-SS-24
NOTE: Remember to slide identifier labels down the power conductors before trimming the cable to its final length
1 2
3 4
5 6
7 8
9 10
Excess Fibre storage Box
Part Number: FE-14126-E
Scan to view video
Cable Splitter tool Part Number: FA-RCRT-PD
Seam Ripper
NOTE: Step can be expedited by using a sewing seam ripper that can be purchased at local hobby stores
Visit www.commscope.com for complete specifications on all the products listed Bulletin # 7693902 Rev. J
Technical Publication
18
AB
CD
EF
GH
JK
LM
****
AB
CD
EF
GH
JK
LM
**** *
1
2
Carefully coil excess Fibre subunit inside of the rack. (Rack will accommodate 50 Metres of excess Fibre)Feed the Fibre subunit 1 thru the slot marked A and the Fibre subunit 2 thru the slot marked B.
Remove the dust caps from the MPO connectors and clean with an all-in-one cleaner (FCCT-MPO). Remove the dust caps from the 12 Fibre cassettes and clean with an all-in-one cleaner (FCCT-MPO).
Connect the MPO connectors to the base of the 12 Fibre cassettes. The Beta label should be on the bottom as shown.
Carefully install the cassettes into the slots making sure the Beta label is still on the bottom.
Part Number:360DM-12LC-SM
Section 11: MPO Installation / Wiring
Mount the rack with provided installation instructions.Remove the slot covers from A - F. G - M are expansion slots
Subunits can enter from bottom (as shown) or top
Repeat steps 2 - 6 for Cables 2 and 3 using slots C - F.
Note: Do not install in a rainy or windy environment without additional shielding of the exposed MPO’s. The exposure of the exposed MPO to the outdoor environment should be minimized even under ideal conditions.
AB
CD
EF
GH
JK
LM
****
AB
CD
EF
GH
JK
LM
**** *
1
2
Cable 1
Cable 2
Cable 3
Expansion slots
AB
CD
EF
GH
JK
LM
****
AB
CD
EF
GH
JK
LM
**** *
1
2
!
X 2
12
AB
CD
EF
GH
JK
LM
****
AB
CD
EF
GH
JK
LM
**** *
******
**
******
**
BETA01-12
ALPH
A01
-12
BETA01-12
ALPH
A01
-12
1
2
AB
CD
EF
GH
JK
LM
****
AB
CD
EF
GH
JK
LM
**** *
******
**
******
**
BETA01-12
ALPH
A01
-12
BETA01-12
ALPH
A01
-12
1
2
AB
CD
EF
GH
JK
LM
****
AB
CD
EF
GH
JK
LM
**** *
******
**
******
**
BETA01-12
ALPH
A01
-12
BETA01-12
ALPH
A01
-12
1
2
AB
CD
EF
GH
JK
LM
****
AB
CD
EF
GH
JK
LM
**** *
******
**
******
**
BETA01-12
ALPH
A01
-12
BETA01-12
ALPH
A01
-12
1
2
Back ViewFront View1 2
3 4
5
Visit www.commscope.com for complete specifications on all the products listed Bulletin # 7693902 Rev. J
Technical Publication
19
A B C D E F G H J K L M
**
**
A B C D E F G H J K L M
**
**
*
****
** **
****
** **
BETA01-12
ALPHA01-12
BETA01-12
ALPHA01-12
1
2
A
FibreBBU End
Patch PanelRRU End
Trunk
1
2
4
3
5
6
1
2
4
3
5
6
A B C D E F G H J K L M
**
**
A B C D E F G H J K L M
**
**
*
****
** **
****
** **
BETA01-12
ALPHA01-12
BETA01-12
ALPHA01-12
1
2
B
7
8
9
12
7
8
10
9
11
12
11
10
Power
BBU End Patch Panel
RRU End Trunk
Pair 1 Black Red
Black Blue
Pair 2 Black Red
Black Blue
Pair 3 Black Red
Black Blue
Pair 4 Black Red
Black Blue
Pair 5 Black Red
Black Blue
Pair 6 Black Red
Black Blue
Cable 1 Wiring
A B C D E F G H J K L M
**
**
A B C D E F G H J K L M
**
**
*
****
** **
****
** **
BETA01-12
ALPHA01-12
BETA01-12
ALPHA01-12
1
2
C
FibreBBU End
Patch PanelRRU End
Trunk
1
2
4
3
5
6
1
2
4
3
5
6
A B C D E F G H J K L M
**
**
A B C D E F G H J K L M
**
**
*
****
** **
****
** **
BETA01-12
ALPHA01-12
BETA01-12
ALPHA01-12
1
2
D
7
8
9
12
7
8
10
9
11
12
11
10
Power
BBU End Patch Panel
RRU End Trunk
Pair 1 Black Red
Black Blue
Pair 2 Black Red
Black Blue
Pair 3 Black Red
Black Blue
Pair 4 Black Red
Black Blue
Pair 5 Black Red
Black Blue
Pair 6 Black Red
Black Blue
Cable 2 Wiring
A B C D E F G H J K L M
**
**
A B C D E F G H J K L M
**
**
*
****
** **
****
** **
BETA01-12
ALPHA01-12
BETA01-12
ALPHA01-12
1
2
E
FibreBBU End
Patch PanelRRU End
Trunk
1
2
4
3
5
6
1
2
4
3
5
6
A B C D E F G H J K L M
**
**
A B C D E F G H J K L M
**
**
*
****
** **
****
** **
BETA01-12
ALPHA01-12
BETA01-12
ALPHA01-12
1
2
F
7
8
9
12
7
8
10
9
11
12
11
10
Power
BBU End Patch Panel
RRU End Trunk
Pair 1 Black Red
Black Blue
Pair 2 Black Red
Black Blue
Pair 3 Black Red
Black Blue
Pair 4 Black Red
Black Blue
Pair 5 Black Red
Black Blue
Pair 6 Black Red
Black Blue
Cable 3 Wiring
Visit www.commscope.com for complete specifications on all the products listed Bulletin # 7693902 Rev. J
Technical Publication
20
Section 12: Jacketing Removal Procedure
1. Score the jacketing 360º
2. Measure 51 mm (2 in) and repeat
3. Identify where the aluminum shielding overlaps, this will feel like a flat spot in the cable
4. Remove a section of jacketing between score marks
5. Lift edge of jacketing
6. Grab lifted edge of jacketing with a pair of pliers and roll on the cable
7. Remove excess adhesive with a piece of emery cloth Scan to view video
Reel Packaging
Carefully remove shrink wrap
After shipment arrives take extra care when removing the over packing. Remove reel from box or cut strap holding the reel to the shipping pallet. Take care not to damage the assembly as you roll the reel to installation location. Excessive nicks and cuts in the outer jacketing can cause failure. Place reel on stands to lift off the ground so the reel can spin freely while still being controlled by hand.
Lift the shrink wrap away from the cable before cutting. Cable is transported on a double flange reel so both ends may be accessed for pre-testing if required.
Place reel on jack stands
Visit www.commscope.com for complete specifications on all the products listed Bulletin # 7693902 Rev. J
Technical Publication
21
© 2016 CommScope
Notice: CommScope disclaims any liability or responsibility for the results of improper or unsafe installation, inspection, maintenance, or removal practices.Aviso: CommScope no acepta ninguna obligación ni responsabilidad como resultado de prácticas incorrectas o peligrosas de instalación, inspección, mantenimiento o retiro.Avis : CommScope décline toute responsabilité pour les conséquences de procédures d’installation, d’inspection, d’entretien ou de retrait incorrectes ou dangereuses.Hinweis: CommScope lehnt jede Haftung oder Verantwortung für Schäden ab, die aufgrund unsachgemäßer Installation, Überprüfung, Wartung oder Demontage auftreten.Atenção: A CommScope abdica do direito de toda responsabilidade pelos resultados de práticas inadequadas e sem segurança de instalação, inspeção, manutenção ou remoção.Avvertenza: CommScope declina eventuali responsabilità derivanti dell’esecuzione di procedure di installazione, ispezione, manutenzione e smontaggio improprie o poco sicure.
CommScope1100 CommScope Place SE P.O. Box 339, Hickory, NC 28603-0339(828) 324-2200 (800) 982-1708www.commscope.com
Customer Service 24 hoursNorth America: +1-800-255-1479 (toll free)Any country: +1-779-435-6500 email: [email protected]
Tails are properly supported to prevent strain on Fibre during severe weather
Bend radius minimums haven't been exceeded
CommScope approved installation accessories are used
Maximum hanger spacing of 0.9 m (3 ft) - 1.2 m (4 ft) is maintained
Visually inspected end face for residual dirt and damage
Avoid migration of contaminations from one connector to another
Check continuity by using LED or lazer light source from one end face and look for light from other end to identify any broken Fibre (Do not look directly at cable with lazer source)
Fibre Connections are engaged and the sectors are consistent with requirements
Cable serial number has been documented in the closeout paperwork and a copy has been left on-site
Installation Check List