Infrared Thermal Imaging Inspection Report-Production Lines

download Infrared Thermal Imaging Inspection Report-Production Lines

of 41

Transcript of Infrared Thermal Imaging Inspection Report-Production Lines

  • 8/18/2019 Infrared Thermal Imaging Inspection Report-Production Lines

    1/41

    Industrial Services Center - Datco78 Al Moultka Al Araby st., Sheraton, 11361 Cairo - EgyptWeb Site: http://www.datcoegypt.com

    1/41 Infrared Thermal Imaging Inspection ReportReport Author: Sherif Mounir AhmedMobile: +2 012 - 85 711 000Email: [email protected]

    Infrared Thermal ImagingInspection Report-ProductionLines

  • 8/18/2019 Infrared Thermal Imaging Inspection Report-Production Lines

    2/41

    Industrial Services Center - Datco78 Al Moultka Al Araby st., Sheraton, 11361 Cairo - EgyptWeb Site: http://www.datcoegypt.com

    2/41 Infrared Thermal Imaging Inspection ReportReport Author: Sherif Mounir AhmedMobile: +2 012 - 85 711 000Email: [email protected]

    15/12/2015 01:54:18 PM °C

    Li1

    28.5

    22.3

    IR_3231.jpg FLIR E50 49025354

    15/12/2015 01:54:18 PM

    DC_3232.jpg

    Text annotations

    Description of analysis & observation Normal conditions are observed, where the production line 1 stopped.

    Measurements °CLi1 Max 24.6

    Min 23.8

     Average 24.1

    ParametersEmissivity 0.95

    Refl. temp. 20 °C

    NoteHeat Exchanger Panel

  • 8/18/2019 Infrared Thermal Imaging Inspection Report-Production Lines

    3/41

    Industrial Services Center - Datco78 Al Moultka Al Araby st., Sheraton, 11361 Cairo - EgyptWeb Site: http://www.datcoegypt.com

    3/41 Infrared Thermal Imaging Inspection ReportReport Author: Sherif Mounir AhmedMobile: +2 012 - 85 711 000Email: [email protected]

    15/12/2015 01:57:27 PM °C

    Li1

    Li2

    36.6

    24.9

    IR_3233.jpg FLIR E50 49025354

    15/12/2015 01:57:27 PM

    DC_3234.jpg

    Text annotations

    Description of analysis & observation Normal conditions are observed, where the production line 1 stopped.

    Measurements °CLi1 Max 28.6

    Min 28.0

     Average 28.4Li2 Max 29.4

    Min 28.0

     Average 28.8

    ParametersEmissivity 0.95

    Refl. temp. 20 °C

    NoteFeyer Panel

  • 8/18/2019 Infrared Thermal Imaging Inspection Report-Production Lines

    4/41

    Industrial Services Center - Datco78 Al Moultka Al Araby st., Sheraton, 11361 Cairo - EgyptWeb Site: http://www.datcoegypt.com

    4/41 Infrared Thermal Imaging Inspection ReportReport Author: Sherif Mounir AhmedMobile: +2 012 - 85 711 000Email: [email protected]

    15/12/2015 02:06:54 PM °C

    Li1

    38.2

    20.2

    IR_3249.jpg FLIR E50 49025354

    15/12/2015 02:06:54 PM

    DC_3250.jpg

    Text annotations

    Description of analysis & observation Normal conditions are observed, where the production line 1 stopped.

    Measurements °CLi1 Max 30.3

    Min 28.0

     Average 29.1

    ParametersEmissivity 0.95

    Refl. temp. 20 °C

    Note 

  • 8/18/2019 Infrared Thermal Imaging Inspection Report-Production Lines

    5/41

    Industrial Services Center - Datco78 Al Moultka Al Araby st., Sheraton, 11361 Cairo - EgyptWeb Site: http://www.datcoegypt.com

    5/41 Infrared Thermal Imaging Inspection ReportReport Author: Sherif Mounir AhmedMobile: +2 012 - 85 711 000Email: [email protected]

    15/12/2015 02:22:10 PM °C

    Li1

    44.0

    29.4

    IR_3273.jpg FLIR E50 49025354

    15/12/2015 02:22:10 PM

    DC_3274.jpg

    Text annotations

    Description of analysis & observation Normal conditions are observed, where the production line 1 stopped.

    Measurements °CLi1 Max 32.3

    Min 30.6

     Average 31.1

    ParametersEmissivity 0.95

    Refl. temp. 20 °C

    NoteSeasoning Loop 1

  • 8/18/2019 Infrared Thermal Imaging Inspection Report-Production Lines

    6/41

    Industrial Services Center - Datco78 Al Moultka Al Araby st., Sheraton, 11361 Cairo - EgyptWeb Site: http://www.datcoegypt.com

    6/41 Infrared Thermal Imaging Inspection ReportReport Author: Sherif Mounir AhmedMobile: +2 012 - 85 711 000Email: [email protected]

    15/12/2015 02:23:43 PM °C

    Li1

    45.2

    27.1

    IR_3275.jpg FLIR E50 49025354

    15/12/2015 02:23:43 PM

    DC_3276.jpg

    Text annotations

    Description of analysis & observation Normal conditions are observed, where the production line 1 stopped

    Measurements °CLi1 Max 31.4

    Min 29.1

     Average 29.8

    ParametersEmissivity 0.95

    Refl. temp. 20 °C

    NoteSeasoning Loop 2

  • 8/18/2019 Infrared Thermal Imaging Inspection Report-Production Lines

    7/41

    Industrial Services Center - Datco78 Al Moultka Al Araby st., Sheraton, 11361 Cairo - EgyptWeb Site: http://www.datcoegypt.com

    7/41 Infrared Thermal Imaging Inspection ReportReport Author: Sherif Mounir AhmedMobile: +2 012 - 85 711 000Email: [email protected]

    15/12/2015 02:25:11 PM °C

    Li1

    42.5

    26.6

    IR_3277.jpg FLIR E50 49025354

    15/12/2015 02:25:11 PM

    DC_3278.jpg

    Text annotations

    Description of analysis & observation Normal conditions are observed, where the production line 1 stopped

    Measurements °CLi1 Max 30.6

    Min 27.9

     Average 28.6

    ParametersEmissivity 0.95

    Refl. temp. 20 °C

    NoteSeasoning Loop 3

  • 8/18/2019 Infrared Thermal Imaging Inspection Report-Production Lines

    8/41

    Industrial Services Center - Datco78 Al Moultka Al Araby st., Sheraton, 11361 Cairo - EgyptWeb Site: http://www.datcoegypt.com

    8/41 Infrared Thermal Imaging Inspection ReportReport Author: Sherif Mounir AhmedMobile: +2 012 - 85 711 000Email: [email protected]

    15/12/2015 02:27:02 PM °C

    Sp1

    Li1

    32.2

    22.2

    IR_3279.jpg FLIR E50 49025354

    15/12/2015 02:27:02 PM

    DC_3280.jpg

    Text annotations

    Description of analysis & observation Normal conditions are observed, where the production line 1 stopped.

    Measurements °CSp1 25.6

    Li1 Max 30.5

    Min 27.3 Average 28.9

    ParametersEmissivity 0.95

    Refl. temp. 20 °C

    NotePacking 1

  • 8/18/2019 Infrared Thermal Imaging Inspection Report-Production Lines

    9/41

    Industrial Services Center - Datco78 Al Moultka Al Araby st., Sheraton, 11361 Cairo - EgyptWeb Site: http://www.datcoegypt.com

    9/41 Infrared Thermal Imaging Inspection ReportReport Author: Sherif Mounir AhmedMobile: +2 012 - 85 711 000Email: [email protected]

    15/12/2015 02:02:40 PM °C

    Li1

    Li2   Li3

    30.5

    22.0

    IR_3241.jpg FLIR E50 49025354

    15/12/2015 02:02:40 PM

    DC_3242.jpg

    Text annotations

    Description of analysis & observation Normal conditions are observed, the temp. diff. is less than 5°C as shown in theabove mentioned measurements table between the max. and the min. spots, whichis an acceptable diff.

     Action / Severity No Action required / No severity

    Code / Fault Normal condition / No fault

    Measurements °CLi1 Max 25.8

    Min 23.3

     Average 25.2Li2 Max 25.9

    Min 25.5

     Average 25.8

    Li3 Max 25.8

    Min 25.6

     Average 25.7

    ParametersEmissivity 0.95

    Refl. temp. 20 °C

    NoteMain Oil Pump Panel

  • 8/18/2019 Infrared Thermal Imaging Inspection Report-Production Lines

    10/41

    Industrial Services Center - Datco78 Al Moultka Al Araby st., Sheraton, 11361 Cairo - EgyptWeb Site: http://www.datcoegypt.com

    10/41 Infrared Thermal Imaging Inspection ReportReport Author: Sherif Mounir AhmedMobile: +2 012 - 85 711 000Email: [email protected]

    15/12/2015 02:04:43 PM °C

    Li1Li2

    29.3

    23.0

    IR_3247.jpg FLIR E50 49025354

    15/12/2015 02:04:43 PM

    DC_3248.jpg

    Text annotations

    Description of analysis & observation Normal conditions are observed, the temp. diff. is less than 5°C as shown in theabove mentioned measurements table between the max. and the min. spots, whichis an acceptable diff.

     Action / Severity No Action required / No severity

    Code / Fault Normal condition / No fault

    Measurements °CLi1 Max 28.5

    Min 27.8

     Average 28.2Li2 Max 29.3

    Min 26.2

     Average 28.8

    ParametersEmissivity 0.95

    Refl. temp. 20 °C

    NotePreparation Panel

  • 8/18/2019 Infrared Thermal Imaging Inspection Report-Production Lines

    11/41

    Industrial Services Center - Datco78 Al Moultka Al Araby st., Sheraton, 11361 Cairo - EgyptWeb Site: http://www.datcoegypt.com

    11/41 Infrared Thermal Imaging Inspection ReportReport Author: Sherif Mounir AhmedMobile: +2 012 - 85 711 000Email: [email protected]

    15/12/2015 02:08:48 PM °C

    Li1

    34.2

    22.1

    IR_3251.jpg FLIR E50 49025354

    15/12/2015 02:08:48 PM

    DC_3252.jpg

    Text annotations

    Description of analysis & observation Normal conditions are observed, the temp. diff. is less than 5°C as shown in theabove mentioned measurements table between the max. and the min. spots, whichis an acceptable diff.

     Action / Severity No Action required / No severity

    Code / Fault Normal condition / No fault

    Measurements °CLi1 Max 24.8

    Min 24.4

     Average 24.6

    ParametersEmissivity 0.95

    Refl. temp. 20 °C

    NoteIntake Extension Panel

  • 8/18/2019 Infrared Thermal Imaging Inspection Report-Production Lines

    12/41

    Industrial Services Center - Datco78 Al Moultka Al Araby st., Sheraton, 11361 Cairo - EgyptWeb Site: http://www.datcoegypt.com

    12/41 Infrared Thermal Imaging Inspection ReportReport Author: Sherif Mounir AhmedMobile: +2 012 - 85 711 000Email: [email protected]

    15/12/2015 02:11:00 PM °C

    Li1

    Li2

    Li3

    35.3

    14.4

    IR_3253.jpg FLIR E50 49025354

    15/12/2015 02:11:00 PM

    DC_3254.jpg

    Text annotations

    Description of analysis & observation Normal conditions are observed, the temp. diff. is less than 5°C as shown in theabove mentioned measurements table between the max. and the min. spots, whichis an acceptable diff.

     Action / Severity No Action required / No severity

    Code / Fault Normal condition / No fault

    Measurements °CLi1 Max 26.7

    Min 24.3

     Average 25.9Li2 Max 26.7

    Min 26.4

     Average 26.6

    Li3 Max 26.3

    Min 25.4

     Average 26.0

    ParametersEmissivity 0.95

    Refl. temp. 20 °C

    Note+PC1-1A

  • 8/18/2019 Infrared Thermal Imaging Inspection Report-Production Lines

    13/41

    Industrial Services Center - Datco78 Al Moultka Al Araby st., Sheraton, 11361 Cairo - EgyptWeb Site: http://www.datcoegypt.com

    13/41 Infrared Thermal Imaging Inspection ReportReport Author: Sherif Mounir AhmedMobile: +2 012 - 85 711 000Email: [email protected]

    15/12/2015 02:12:31 PM °C

    Li1

    Li2

    37.2

    25.8

    IR_3257.jpg FLIR E50 49025354

    15/12/2015 02:12:31 PM

    DC_3258.jpg

    Text annotations

    Description of analysis & observation Normal conditions are observed, the temp. diff. is less than 5°C as shown in theabove mentioned measurements table between the max. and the min. spots, whichis an acceptable diff.

     Action / Severity No Action required / No severity

    Code / Fault Normal condition / No fault

    Measurements °CLi1 Max 28.0

    Min 27.1

     Average 27.4Li2 Max 26.9

    Min 26.2

     Average 26.7

    ParametersEmissivity 0.95

    Refl. temp. 20 °C

    NoteIntake Extension Panel 2

  • 8/18/2019 Infrared Thermal Imaging Inspection Report-Production Lines

    14/41

    Industrial Services Center - Datco78 Al Moultka Al Araby st., Sheraton, 11361 Cairo - EgyptWeb Site: http://www.datcoegypt.com

    14/41 Infrared Thermal Imaging Inspection ReportReport Author: Sherif Mounir AhmedMobile: +2 012 - 85 711 000Email: [email protected]

    15/12/2015 02:15:57 PM °C

    Sp1

    Li1

    Li2

    36.8

    24.6

    IR_3261.jpg FLIR E50 49025354

    15/12/2015 02:15:57 PM

    DC_3262.jpg

    Text annotations

    Description of analysis & observation Normal conditions are observed, the temp. diff. is less than 5°C as shown in theabove mentioned measurements table between the max. and the min. spots, whichis an acceptable diff.

     Action / Severity No Action required / No severity

    Code / Fault Normal condition / No fault

    Measurements °CSp1 31.3

    Li1 Max 33.4

    Min 30.8 Average 32.2

    Li2 Max 33.3

    Min 31.1

     Average 32.5

    ParametersEmissivity 0.95

    Refl. temp. 20 °C

    NotePotato Preparation Panel

  • 8/18/2019 Infrared Thermal Imaging Inspection Report-Production Lines

    15/41

    Industrial Services Center - Datco78 Al Moultka Al Araby st., Sheraton, 11361 Cairo - EgyptWeb Site: http://www.datcoegypt.com

    15/41 Infrared Thermal Imaging Inspection ReportReport Author: Sherif Mounir AhmedMobile: +2 012 - 85 711 000Email: [email protected]

    15/12/2015 02:17:41 PM °C

    Li1Li2

    Li3

    34.6

    24.1

    IR_3265.jpg FLIR E50 49025354

    15/12/2015 02:17:41 PM

    DC_3266.jpg

    Text annotations

    Description of analysis & observation Normal conditions are observed, the temp. diff. is less than 5°C as shown in theabove mentioned measurements table between the max. and the min. spots, whichis an acceptable diff.

     Action / Severity No Action required / No severity

    Code / Fault Normal condition / No fault

    Measurements °CLi1 Max 26.5

    Min 25.9

     Average 26.2Li2 Max 26.8

    Min 26.1

     Average 26.4

    Li3 Max 26.5

    Min 25.4

     Average 26.0

    ParametersEmissivity 0.95

    Refl. temp. 20 °C

    NoteM.O.P Panel

  • 8/18/2019 Infrared Thermal Imaging Inspection Report-Production Lines

    16/41

    Industrial Services Center - Datco78 Al Moultka Al Araby st., Sheraton, 11361 Cairo - EgyptWeb Site: http://www.datcoegypt.com

    16/41 Infrared Thermal Imaging Inspection ReportReport Author: Sherif Mounir AhmedMobile: +2 012 - 85 711 000Email: [email protected]

    15/12/2015 02:17:59 PM °C

    Li1

    Li2

    32.7

    24.3

    IR_3267.jpg FLIR E50 49025354

    15/12/2015 02:17:59 PM

    DC_3268.jpg

    Text annotations

    Description of analysis & observation Normal conditions are observed, the temp. diff. is less than 5°C as shown in theabove mentioned measurements table between the max. and the min. spots, whichis an acceptable diff.

     Action / Severity No Action required / No severity

    Code / Fault Normal condition / No fault

    Measurements °CLi1 Max 30.7

    Min 29.2

     Average 29.7Li2 Max 28.1

    Min 26.5

     Average 27.2

    ParametersEmissivity 0.95

    Refl. temp. 20 °C

    NoteM.O.P Panel

  • 8/18/2019 Infrared Thermal Imaging Inspection Report-Production Lines

    17/41

    Industrial Services Center - Datco78 Al Moultka Al Araby st., Sheraton, 11361 Cairo - EgyptWeb Site: http://www.datcoegypt.com

    17/41 Infrared Thermal Imaging Inspection ReportReport Author: Sherif Mounir AhmedMobile: +2 012 - 85 711 000Email: [email protected]

    15/12/2015 02:19:56 PM °C

    Li1

    Li2

    Li3

    Li4

    29.1

    23.1

    IR_3269.jpg FLIR E50 49025354

    15/12/2015 02:19:56 PM

    DC_3270.jpg

    Text annotations

    Description of analysis & observation Normal conditions are observed, the temp. diff. is less than 5°C as shown in theabove mentioned measurements table between the max. and the min. spots, whichis an acceptable diff.

     Action / Severity No Action required / No severity

    Code / Fault Normal condition / No fault

    Measurements °CLi1 Max 24.3

    Min 23.4

     Average 23.7Li2 Max 24.5

    Min 23.2

     Average 23.8

    Li3 Max 24.8

    Min 24.0

     Average 24.4

    Li4 Max 25.1

    Min 24.1

     Average 24.5

    ParametersEmissivity 0.95

    Refl. temp. 20 °C

    NoteSlice wash & Fryer Panel

  • 8/18/2019 Infrared Thermal Imaging Inspection Report-Production Lines

    18/41

    Industrial Services Center - Datco78 Al Moultka Al Araby st., Sheraton, 11361 Cairo - EgyptWeb Site: http://www.datcoegypt.com

    18/41 Infrared Thermal Imaging Inspection ReportReport Author: Sherif Mounir AhmedMobile: +2 012 - 85 711 000Email: [email protected]

    15/12/2015 02:20:17 PM °C

    Sp1

    Li1

    29.6

    20.1

    IR_3271.jpg FLIR E50 49025354

    15/12/2015 02:20:17 PM

    DC_3272.jpg

    Text annotations

    Description of analysis & observation Normal conditions are observed, the temp. diff. is less than 5°C as shown in theabove mentioned measurements table between the max. and the min. spots, whichis an acceptable diff.

     Action / Severity No Action required / No severity

    Code / Fault Normal condition / No fault

    Measurements °CSp1 27.8

    Li1 Max 26.8

    Min 26.1 Average 26.4

    ParametersEmissivity 0.95

    Refl. temp. 20 °C

    NoteSlice wash & Fryer Panel

  • 8/18/2019 Infrared Thermal Imaging Inspection Report-Production Lines

    19/41

    Industrial Services Center - Datco78 Al Moultka Al Araby st., Sheraton, 11361 Cairo - EgyptWeb Site: http://www.datcoegypt.com

    19/41 Infrared Thermal Imaging Inspection ReportReport Author: Sherif Mounir AhmedMobile: +2 012 - 85 711 000Email: [email protected]

    15/12/2015 02:28:43 PM °C

    Li1

    Li2

    Li3

    Li4

    Li5

    39.2

    21.3

    IR_3281.jpg FLIR E50 49025354

    15/12/2015 02:28:43 PM

    DC_3282.jpg

    Text annotations

    Description of analysis & observation Normal conditions are observed, the temp. diff. is less than 5°C as shown in theabove mentioned measurements table between the max. and the min. spots, whichis an acceptable diff.

     Action / Severity No Action required / No severity

    Code / Fault Normal condition / No fault

    Measurements °CLi1 Max 39.0

    Min 35.4

     Average 37.0Li2 Max 34.3

    Min 31.7

     Average 32.7

    Li3 Max 31.1

    Min 28.9

     Average 29.9

    Li4 Max 29.5

    Min 27.8

     Average 28.9

    Li5 Max 32.6

    Min 30.4

     Average 31.7

    ParametersEmissivity 0.95

    Refl. temp. 20 °C

    NotePacking 2

  • 8/18/2019 Infrared Thermal Imaging Inspection Report-Production Lines

    20/41

    Industrial Services Center - Datco78 Al Moultka Al Araby st., Sheraton, 11361 Cairo - EgyptWeb Site: http://www.datcoegypt.com

    20/41 Infrared Thermal Imaging Inspection ReportReport Author: Sherif Mounir AhmedMobile: +2 012 - 85 711 000Email: [email protected]

    15/12/2015 02:31:22 PM °C

    Li1

    Li2

    44.4

    28.3

    IR_3283.jpg FLIR E50 4902535415/12/2015 02:31:22 PM

    DC_3284.jpgxt annotations

    scription of analysis & observation Raised temperature are observed on line (2).

    ion / Severity Monitor development and repair as necessary required for the Li (2). / low severity

    de / Fault Four / Alert

    ential impact upon severity Occur short circuiting/turn-to-turn faults.

    nditions Found/Deviation Loose connections/poor contacts/rust/unbalanced loads/deteriorated internal contact/overloading/overheating is of concern.

    ysical inspection/Electrical testing/Remedy The source of the raised temperature shall be investigated and eliminated by cleaning/tighten theconnection/inspection the internal component/change the component, if possible.

    Measurements °CLi1 Max 40.3

    Min 31.6

     Average 36.8Li2 Max 47.9

    Min 38.5

     Average 42.6

    ParametersEmissivity 0.95

    Refl. temp. 20 °C

    NoteSeasoning Loop 4

  • 8/18/2019 Infrared Thermal Imaging Inspection Report-Production Lines

    21/41

    Industrial Services Center - Datco78 Al Moultka Al Araby st., Sheraton, 11361 Cairo - EgyptWeb Site: http://www.datcoegypt.com

    21/41 Infrared Thermal Imaging Inspection ReportReport Author: Sherif Mounir AhmedMobile: +2 012 - 85 711 000Email: [email protected]

    15/12/2015 02:33:02 PM °C

    Li1

    39.9

    25.0

    IR_3285.jpg FLIR E50 49025354

    15/12/2015 02:33:02 PM

    DC_3286.jpg

    Text annotations

    Description of analysis & observation Normal conditions are observed, the temp. diff. is less than 5°C as shown in theabove mentioned measurements table between the max. and the min. spots, which isan acceptable diff.

     Action / Severity No Action required / No severity

    Code / Fault Normal condition / No fault

    Measurements °CLi1 Max 32.8

    Min 27.8

     Average 29.7

    ParametersEmissivity 0.95

    Refl. temp. 20 °C

    NoteHeat Exchanger 2

  • 8/18/2019 Infrared Thermal Imaging Inspection Report-Production Lines

    22/41

    Industrial Services Center - Datco78 Al Moultka Al Araby st., Sheraton, 11361 Cairo - EgyptWeb Site: http://www.datcoegypt.com

    22/41 Infrared Thermal Imaging Inspection ReportReport Author: Sherif Mounir AhmedMobile: +2 012 - 85 711 000Email: [email protected]

    15/12/2015 02:34:49 PM °C

    Sp1Sp2   Sp3

    Li1

    39.6

    27.8

    IR_3291.jpg FLIR E50 49025354

    15/12/2015 02:34:49 PM

    DC_3292.jpg

    Text annotations

    Description of analysis & observation Normal conditions are observed, the temp. diff. is less than 5°C as shown in theabove mentioned measurements table between the max. and the min. spots, which isan acceptable diff.

     Action / Severity No Action required / No severity

    Code / Fault Normal condition / No fault

    Measurements °CSp1 34.8

    Sp2 36.1

    Sp3 37.5Li1 Max 35.6

    Min 31.5

     Average 33.5

    ParametersEmissivity 0.95

    Refl. temp. 20 °C

    NoteHeat Exchanger 3

  • 8/18/2019 Infrared Thermal Imaging Inspection Report-Production Lines

    23/41

    Industrial Services Center - Datco78 Al Moultka Al Araby st., Sheraton, 11361 Cairo - EgyptWeb Site: http://www.datcoegypt.com

    23/41 Infrared Thermal Imaging Inspection ReportReport Author: Sherif Mounir AhmedMobile: +2 012 - 85 711 000Email: [email protected]

    15/12/2015 02:36:23 PM °C

    Sp1

    Li1

    39.1

    20.5

    IR_3297.jpg FLIR E50 49025354

    15/12/2015 02:36:23 PM

    DC_3298.jpg

    Text annotations

    Description of analysis & observation Normal conditions are observed, the temp. diff. is less than 5°C as shown in theabove mentioned measurements table between the max. and the min. spots, whichis an acceptable diff.

     Action / Severity No Action required / No severity

    Code / Fault Normal condition / No fault

    Measurements °CSp1 22.9

    Li1 Max 23.7

    Min 21.8 Average 22.4

    ParametersEmissivity 0.95

    Refl. temp. 20 °C

    Note 3

  • 8/18/2019 Infrared Thermal Imaging Inspection Report-Production Lines

    24/41

    Industrial Services Center - Datco78 Al Moultka Al Araby st., Sheraton, 11361 Cairo - EgyptWeb Site: http://www.datcoegypt.com

    24/41 Infrared Thermal Imaging Inspection ReportReport Author: Sherif Mounir AhmedMobile: +2 012 - 85 711 000Email: [email protected]

    15/12/2015 02:38:13 PM °C

    Li1

    Li2

    31.8

    15.2

    IR_3301.jpg FLIR E50 49025354

    15/12/2015 02:38:13 PM

    DC_3302.jpg

    Text annotations

    Description of analysis & observation Normal conditions are observed, the temp. diff. is less than 5°C as shown in theabove mentioned measurements table between the max. and the min. spots, whichis an acceptable diff.

     Action / Severity No Action required / No severity

    Code / Fault Normal condition / No fault

    Measurements °CLi1 Max 24.1

    Min 23.5

     Average 23.8Li2 Max 23.9

    Min 23.8

     Average 23.9

    ParametersEmissivity 0.95

    Refl. temp. 20 °C

    NotePreparation Line 3

  • 8/18/2019 Infrared Thermal Imaging Inspection Report-Production Lines

    25/41

    Industrial Services Center - Datco78 Al Moultka Al Araby st., Sheraton, 11361 Cairo - EgyptWeb Site: http://www.datcoegypt.com

    25/41 Infrared Thermal Imaging Inspection ReportReport Author: Sherif Mounir AhmedMobile: +2 012 - 85 711 000Email: [email protected]

    15/12/2015 02:38:44 PM °C

    Li1

    Li2

    Li3

    Li4

    35.3

    25.4

    IR_3305.jpg FLIR E50 49025354

    15/12/2015 02:38:44 PM

    DC_3306.jpg

    Text annotations

    Description of analysis & observation Normal conditions are observed, the temp. diff. is less than 5°C as shown in theabove mentioned measurements table between the max. and the min. spots, whichis an acceptable diff.

     Action / Severity No Action required / No severity

    Code / Fault Normal condition / No fault

    Measurements °CLi1 Max 31.3

    Min 30.6

     Average 30.9Li2 Max 30.8

    Min 27.1

     Average 29.5

    Li3 Max 35.7

    Min 33.4

     Average 34.5

    Li4 Max 35.4

    Min 28.6

     Average 32.0

    ParametersEmissivity 0.95

    Refl. temp. 20 °C

    NotePreparation Line 3

  • 8/18/2019 Infrared Thermal Imaging Inspection Report-Production Lines

    26/41

    Industrial Services Center - Datco78 Al Moultka Al Araby st., Sheraton, 11361 Cairo - EgyptWeb Site: http://www.datcoegypt.com

    26/41 Infrared Thermal Imaging Inspection ReportReport Author: Sherif Mounir AhmedMobile: +2 012 - 85 711 000Email: [email protected]

    15/12/2015 02:40:44 PM °C

    Li1

    Li2

    40.0

    25.6

    IR_3311.jpg FLIR E50 49025354

    15/12/2015 02:40:44 PM

    DC_3312.jpg

    Text annotations

    Description of analysis & observation Normal conditions are observed, the temp. diff. is less than 5°C as shown in theabove mentioned measurements table between the max. and the min. spots, whichis an acceptable diff.

     Action / Severity No Action required / No severity

    Code / Fault Normal condition / No fault

    Measurements °CLi1 Max 37.9

    Min 29.8

     Average 34.4Li2 Max 36.6

    Min 28.7

     Average 32.1

    ParametersEmissivity 0.95

    Refl. temp. 20 °C

    NoteM.O.P Panel

  • 8/18/2019 Infrared Thermal Imaging Inspection Report-Production Lines

    27/41

    Industrial Services Center - Datco78 Al Moultka Al Araby st., Sheraton, 11361 Cairo - EgyptWeb Site: http://www.datcoegypt.com

    27/41 Infrared Thermal Imaging Inspection ReportReport Author: Sherif Mounir AhmedMobile: +2 012 - 85 711 000Email: [email protected]

    15/12/2015 02:40:33 PM °C

    Li1

    39.0

    25.6

    IR_3309.jpg FLIR E50 49025354

    15/12/2015 02:40:33 PM

    DC_3310.jpg

    Text annotations

    Description of analysis & observation Normal conditions are observed, the temp. diff. is less than 5°C as shown in theabove mentioned measurements table between the max. and the min. spots, whichis an acceptable diff.

     Action / Severity No Action required / No severity

    Code / Fault Normal condition / No fault

    Measurements °CLi1 Max 37.9

    Min 28.7

     Average 34.4

    ParametersEmissivity 0.95

    Refl. temp. 20 °C

    NoteM.O.P Panel

  • 8/18/2019 Infrared Thermal Imaging Inspection Report-Production Lines

    28/41

    Industrial Services Center - Datco78 Al Moultka Al Araby st., Sheraton, 11361 Cairo - EgyptWeb Site: http://www.datcoegypt.com

    28/41 Infrared Thermal Imaging Inspection ReportReport Author: Sherif Mounir AhmedMobile: +2 012 - 85 711 000Email: [email protected]

    15/12/2015 02:42:35 PM °C

    Li1

    Li2

    29.6

    14.3

    IR_3313.jpg FLIR E50 49025354

    15/12/2015 02:42:35 PM

    DC_3314.jpg

    Text annotations

    Description of analysis & observation Normal conditions are observed, the temp. diff. is less than 5°C as shown in theabove mentioned measurements table between the max. and the min. spots, whichis an acceptable diff.

     Action / Severity No Action required / No severity

    Code / Fault Normal condition / No fault

    Measurements °CLi1 Max 18.5

    Min 15.4

     Average 16.8Li2 Max 21.2

    Min 19.9

     Average 20.5

    ParametersEmissivity 0.95

    Refl. temp. 20 °C

    NoteSlice wash & Fryer Panel

  • 8/18/2019 Infrared Thermal Imaging Inspection Report-Production Lines

    29/41

    Industrial Services Center - Datco78 Al Moultka Al Araby st., Sheraton, 11361 Cairo - EgyptWeb Site: http://www.datcoegypt.com

    29/41 Infrared Thermal Imaging Inspection ReportReport Author: Sherif Mounir AhmedMobile: +2 012 - 85 711 000Email: [email protected]

    15/12/2015 02:43:15 PM °C

    Li1Li2

    Li3Li4

    34.2

    26.2

    IR_3315.jpg FLIR E50 49025354

    15/12/2015 02:43:15 PM

    DC_3316.jpg

    Text annotations

    Description of analysis & observation Normal conditions are observed, the temp. diff. is less than 5°C as shown in theabove mentioned measurements table between the max. and the min. spots, whichis an acceptable diff.

     Action / Severity No Action required / No severity

    Code / Fault Normal condition / No fault

    Measurements °CLi1 Max 28.9

    Min 27.9

     Average 28.3Li2 Max 28.7

    Min 27.5

     Average 28.2

    Li3 Max 28.8

    Min 27.0

     Average 27.8

    Li4 Max 28.7

    Min 27.4

     Average 28.0

    ParametersEmissivity 0.95

    Refl. temp. 20 °C

    NoteSlice wash & Fryer Panel

  • 8/18/2019 Infrared Thermal Imaging Inspection Report-Production Lines

    30/41

    Industrial Services Center - Datco78 Al Moultka Al Araby st., Sheraton, 11361 Cairo - EgyptWeb Site: http://www.datcoegypt.com

    30/41 Infrared Thermal Imaging Inspection ReportReport Author: Sherif Mounir AhmedMobile: +2 012 - 85 711 000Email: [email protected]

    15/12/2015 02:46:12 PM °C

    Li1

    Li2

    41.8

    27.0

    IR_3317.jpg FLIR E50 49025354

    Measurements °CLi1 Max 42.5

    Min 41.3

     Average 42.1Li2 Max 43.0

    Min 35.6

     Average 38.7

    ParametersEmissivity 0.95

    Refl. temp. 20 °C

    NoteSeasoning Loop 5

    15/12/2015 02:46:12 PM

    DC_3318.jpg

    Text annotations

    Description of analysis & observation Normal conditions are observed, the temp. diff. is less than 5°C as shown in theabove mentioned measurements table between the max. and the min. spots, whichis an acceptable diff.

     Action / Severity No Action required / No severity

    Code / Fault Normal condition / No fault

  • 8/18/2019 Infrared Thermal Imaging Inspection Report-Production Lines

    31/41

    Industrial Services Center - Datco78 Al Moultka Al Araby st., Sheraton, 11361 Cairo - EgyptWeb Site: http://www.datcoegypt.com

    31/41 Infrared Thermal Imaging Inspection ReportReport Author: Sherif Mounir AhmedMobile: +2 012 - 85 711 000Email: [email protected]

    15/12/2015 02:47:36 PM °C

    Li1

    Li2

    34.0

    24.9

    IR_3319.jpg FLIR E50 49025354

    Measurements °CLi1 Max 33.3

    Min 28.2

     Average 31.2Li2 Max 33.5

    Min 29.5

     Average 30.8

    ParametersEmissivity 0.95

    Refl. temp. 20 °C

    NoteSeasoning Loop 6

    15/12/2015 02:47:36 PM

    DC_3320.jpg

    Text annotations

    Description of analysis & observation Normal conditions are observed, the temp. diff. is less than 5°C as shown in theabove mentioned measurements table between the max. and the min. spots, whichis an acceptable diff.

     Action / Severity No Action required / No severity

    Code / Fault Normal condition / No fault

  • 8/18/2019 Infrared Thermal Imaging Inspection Report-Production Lines

    32/41

    Industrial Services Center - Datco78 Al Moultka Al Araby st., Sheraton, 11361 Cairo - EgyptWeb Site: http://www.datcoegypt.com

    32/41 Infrared Thermal Imaging Inspection ReportReport Author: Sherif Mounir AhmedMobile: +2 012 - 85 711 000Email: [email protected]

    15/12/2015 03:02:51 PM °C

    Li1

    Li2

    28.7

    19.5

    IR_3341.jpg FLIR E50 49025354

    Measurements °CLi1 Max 23.4

    Min 22.9

     Average 23.1Li2 Max 23.5

    Min 22.6

     Average 22.8

    ParametersEmissivity 0.95

    Refl. temp. 20 °C

    NotePacking 3

    15/12/2015 03:02:51 PM

    DC_3342.jpg

    Text annotations

    Description of analysis & observation Normal conditions are observed, the temp. diff. is less than 5°C as shown in theabove mentioned measurements table between the max. and the min. spots, whichis an acceptable diff.

     Action / Severity No Action required / No severity

    Code / Fault Normal condition / No fault

  • 8/18/2019 Infrared Thermal Imaging Inspection Report-Production Lines

    33/41

    Industrial Services Center - Datco78 Al Moultka Al Araby st., Sheraton, 11361 Cairo - EgyptWeb Site: http://www.datcoegypt.com

    33/41 Infrared Thermal Imaging Inspection ReportReport Author: Sherif Mounir AhmedMobile: +2 012 - 85 711 000Email: [email protected]

    15/12/2015 02:50:17 PM °C

    Li1

    30.5

    25.2

    IR_3321.jpg FLIR E50 49025354

    Measurements °CLi1 Max 30.2

    Min 29.2

     Average 29.6

    ParametersEmissivity 0.95

    Refl. temp. 20 °C

    NoteOven RPS

    15/12/2015 02:50:17 PM

    DC_3322.jpg

    Text annotations

    Description of analysis & observation Normal conditions are observed, the temp. diff. is less than 5°C as shown in theabove mentioned measurements table between the max. and the min. spots, whichis an acceptable diff.

     Action / Severity No Action required / No severity

    Code / Fault Normal condition / No fault

  • 8/18/2019 Infrared Thermal Imaging Inspection Report-Production Lines

    34/41

    Industrial Services Center - Datco78 Al Moultka Al Araby st., Sheraton, 11361 Cairo - EgyptWeb Site: http://www.datcoegypt.com

    34/41 Infrared Thermal Imaging Inspection ReportReport Author: Sherif Mounir AhmedMobile: +2 012 - 85 711 000Email: [email protected]

    15/12/2015 02:50:29 PM °C

    Li1

    Li2

    Li3

    Li4

    Li5

    31.9

    24.8

    IR_3323.jpg FLIR E50 49025354

    Measurements °CLi1 Max 29.9

    Min 29.4

     Average 29.7Li2 Max 29.9

    Min 29.5

     Average 29.7

    Li3 Max 32.0

    Min 30.9

     Average 31.6

    Li4 Max 31.5

    Min 31.0

     Average 31.3

    Li5 Max 30.9

    Min 30.4

     Average 30.7

    ParametersEmissivity 0.95

    Refl. temp. 20 °C

    NoteOven RPS

    15/12/2015 02:50:29 PM

    DC_3324.jpg

    Text annotations

    Description of analysis & observation Normal conditions are observed, the temp. diff. is less than 5°C as shown in theabove mentioned measurements table between the max. and the min. spots, whichis an acceptable diff.

     Action / Severity No Action required / No severity

    Code / Fault Normal condition / No fault

  • 8/18/2019 Infrared Thermal Imaging Inspection Report-Production Lines

    35/41

    Industrial Services Center - Datco78 Al Moultka Al Araby st., Sheraton, 11361 Cairo - EgyptWeb Site: http://www.datcoegypt.com

    35/41 Infrared Thermal Imaging Inspection ReportReport Author: Sherif Mounir AhmedMobile: +2 012 - 85 711 000Email: [email protected]

    15/12/2015 02:50:45 PM °C

    Li1   Li2

    Li3

    41.7

    26.0

    IR_3325.jpg FLIR E50 49025354

    Measurements °CLi1 Max 31.2

    Min 29.8

     Average 30.4Li2 Max 31.6

    Min 30.5

     Average 31.0

    Li3 Max 38.0

    Min 35.3

     Average 36.7

    ParametersEmissivity 0.95

    Refl. temp. 20 °C

    NoteOven RPS

    15/12/2015 02:50:45 PM

    DC_3326.jpg

    Text annotations

    Description of analysis & observation Normal conditions are observed, the temp. diff. is less than 5°C as shown in theabove mentioned measurements table between the max. and the min. spots, whichis an acceptable diff.

     Action / Severity No Action required / No severity

    Code / Fault Normal condition / No fault

  • 8/18/2019 Infrared Thermal Imaging Inspection Report-Production Lines

    36/41

    Industrial Services Center - Datco78 Al Moultka Al Araby st., Sheraton, 11361 Cairo - EgyptWeb Site: http://www.datcoegypt.com

    36/41 Infrared Thermal Imaging Inspection ReportReport Author: Sherif Mounir AhmedMobile: +2 012 - 85 711 000Email: [email protected]

    15/12/2015 02:52:45 PM °C

    Li1

    33.6

    27.9

    IR_3327.jpg FLIR E50 49025354

    Measurements °CLi1 Max 29.1

    Min 28.8

     Average 29.0

    ParametersEmissivity 0.95

    Refl. temp. 20 °C

    NoteProcess Control Panel

    15/12/2015 02:52:45 PM

    DC_3328.jpg

    Text annotations

    Description of analysis & observation Normal conditions are observed, the temp. diff. is less than 5°C as shown in theabove mentioned measurements table between the max. and the min. spots, whichis an acceptable diff.

     Action / Severity No Action required / No severity

    Code / Fault Normal condition / No fault

  • 8/18/2019 Infrared Thermal Imaging Inspection Report-Production Lines

    37/41

    Industrial Services Center - Datco78 Al Moultka Al Araby st., Sheraton, 11361 Cairo - EgyptWeb Site: http://www.datcoegypt.com

    37/41 Infrared Thermal Imaging Inspection ReportReport Author: Sherif Mounir AhmedMobile: +2 012 - 85 711 000Email: [email protected]

    15/12/2015 02:52:57 PM °C

    Li1

    Li2

    Li3

    Li4

    33.9

    26.4

    IR_3329.jpg FLIR E50 49025354

    Measurements °CLi1 Max 29.4

    Min 29.1

     Average 29.2Li2 Max 29.2

    Min 29.0

     Average 29.1

    Li3 Max 29.3

    Min 28.9

     Average 29.1

    Li4 Max 31.3

    Min 30.4

     Average 30.9

    ParametersEmissivity 0.95

    Refl. temp. 20 °C

    15/12/2015 02:52:57 PM

    DC_3330.jpg

    Text annotations

    Description of analysis & observation Normal conditions are observed, the temp. diff. is less than 5°C as shown in theabove mentioned measurements table between the max. and the min. spots, whichis an acceptable diff.

     Action / Severity No Action required / No severity

    Code / Fault Normal condition / No fault

  • 8/18/2019 Infrared Thermal Imaging Inspection Report-Production Lines

    38/41

    Industrial Services Center - Datco78 Al Moultka Al Araby st., Sheraton, 11361 Cairo - EgyptWeb Site: http://www.datcoegypt.com

    38/41 Infrared Thermal Imaging Inspection ReportReport Author: Sherif Mounir AhmedMobile: +2 012 - 85 711 000Email: [email protected]

    15/12/2015 02:53:40 PM °C

    Li1   Li2Li3

    59.3

    26.5

    IR_3333.jpg FLIR E50 49025354

    Measurements °CLi1 Max 34.6

    Min 33.0

     Average 33.6Li2 Max 44.3

    Min 39.6

     Average 42.0

    Li3 Max 34.0

    Min 31.3

     Average 32.2

    ParametersEmissivity 0.95

    Refl. temp. 20 °C

    NoteProcess Control Panel

    15/12/2015 02:53:40 PM

    DC_3334.jpg

    Text annotations

    Description of analysis & observation Normal conditions are observed as the temp. diff. on the midle component is moreloaded than other component otherwise temp. diff. for each component is anacceptable.

     Action / Severity No Action required / No severity

    Code / Fault Normal condition / No fault

  • 8/18/2019 Infrared Thermal Imaging Inspection Report-Production Lines

    39/41

    Industrial Services Center - Datco78 Al Moultka Al Araby st., Sheraton, 11361 Cairo - EgyptWeb Site: http://www.datcoegypt.com

    39/41 Infrared Thermal Imaging Inspection ReportReport Author: Sherif Mounir AhmedMobile: +2 012 - 85 711 000Email: [email protected]

    15/12/2015 02:53:51 PM °C

    Li1 Li2

    40.2

    27.8

    IR_3335.jpg FLIR E50 49025354

    Measurements °CLi1 Max 33.6

    Min 29.2

     Average 31.1Li2 Max 31.7

    Min 28.7

     Average 30.4

    ParametersEmissivity 0.95

    Refl. temp. 20 °C

    NoteProcess Control Panel

    15/12/2015 02:53:51 PM

    DC_3336.jpg

    Text annotations

    Description of analysis & observation Normal conditions are observed, the temp. diff. is less than 5°C as shown in theabove mentioned measurements table between the max. and the min. spots, which isan acceptable diff.

     Action / Severity No Action required / No severity

    Code / Fault Normal condition / No fault

  • 8/18/2019 Infrared Thermal Imaging Inspection Report-Production Lines

    40/41

    Industrial Services Center - Datco78 Al Moultka Al Araby st., Sheraton, 11361 Cairo - EgyptWeb Site: http://www.datcoegypt.com

    40/41 Infrared Thermal Imaging Inspection ReportReport Author: Sherif Mounir AhmedMobile: +2 012 - 85 711 000Email: [email protected]

    15/12/2015 02:56:59 PM °C

    Li1

    Li2

    33.1

    23.9

    IR_3337.jpg FLIR E50 49025354

    Measurements °CLi1 Max 32.8

    Min 31.1

     Average 32.2Li2 Max 30.6

    Min 29.3

     Average 30.2

    ParametersEmissivity 0.95

    Refl. temp. 20 °C

    NoteSeasoning Loop 7

    15/12/2015 02:56:59 PM

    DC_3338.jpg

    Text annotations

    Description of analysis & observation Normal conditions are observed, the temp. diff. is less than 5°C as shown in theabove mentioned measurements table between the max. and the min. spots, whichis an acceptable diff.

     Action / Severity No Action required / No severity

    Code / Fault Normal condition / No fault

  • 8/18/2019 Infrared Thermal Imaging Inspection Report-Production Lines

    41/41

    Industrial Services Center - Datco78 Al Moultka Al Araby st., Sheraton, 11361 Cairo - EgyptWeb Site: http://www.datcoegypt.com

    15/12/2015 02:59:59 PM °C

    Sp1

    Li1

    34.5

    23.7

    IR_3339.jpg FLIR E50 49025354

    Measurements °CSp1 28.9

    Li1 Max 29.7

    Min 28.3 Average 28.9

    ParametersEmissivity 0.95

    Refl. temp. 20 °C

    NotePacking 4

    15/12/2015 02:59:59 PM

    DC_3340.jpg

    Text annotations

    Description of analysis & observation Normal conditions are observed, the temp. diff. is less than 5°C as shown in theabove mentioned measurements table between the max. and the min. spots, whichis an acceptable diff.

     Action / Severity No Action required / No severity

    Code / Fault Normal condition / No fault