Indoor Air Quality Assurance In A Dental Environment.

Transcript of Indoor Air Quality Assurance In A Dental Environment.Dental.presentation ( october 2012) by...

Page 1: Indoor Air Quality Assurance In A Dental Environment.Dental.presentation ( october 2012) by somamedical.net

� Commercial & Office Buildings

� Schools

� Daycare Centres

� Hospital & Clean Rooms

� Smoking Environment

� Manufacturing/Factories

� Government Buildings & Facilities

� Fire Departments

� Police Departments

Indoor Air Quality Assurance In A

Dental Environment

www.somamedical.net

Page 2: Indoor Air Quality Assurance In A Dental Environment.Dental.presentation ( october 2012) by somamedical.net
Page 3: Indoor Air Quality Assurance In A Dental Environment.Dental.presentation ( october 2012) by somamedical.net

Fundamental Principle Of Dental

I.A.Q.( Indoor Air Quality).

Environmental Surfaces

Contaminated patient care items and surfaces pose different degrees of risk for infection

transmission based on their location and potential to transmit pathogens. With regard to

environmental surfaces, the latest precautionary dental guidelines also provide a better

understanding of how to discriminate between the two categories of environmental

surfaces: clinical contact surfaces and housekeeping surfaces

Categories of Contaminated Environmental Surfaces

Category Definition Examples

Clinical contact Surfaces that are directly

contacted by contaminated

instruments, devices, hands,

or gloves

Dental unit surfaces, laboratory

equipment, reusable containers of

dental materials, drawer handles,

heavily used countertops, pens,

telephone handles, doorknobs

Housekeeping Surfaces that require regular

cleaning to remove soil and

dust but that rarely contact

dental personnel or patients

Floors, walls, lightly used

countertops

Page 4: Indoor Air Quality Assurance In A Dental Environment.Dental.presentation ( october 2012) by somamedical.net

Environmental Decontamination In Dentistry

“A high level of general cleanliness must be maintained in dental surgery.

Working surfaces, bracket tables and countertops should be disinfected. The

use of sterilize-able trays or disposables are recommended. Floors, walls and

sinks must be routinely cleaned. All spilt blood or body fluids must be

attended to immediately.“

The phrase “risk of aerosols contamination“ means :

1. “General cleanliness”, “routinely cleaned” are not enough.

2. “Spilt blood and body fluids” might not be attended too immediately.

3. Aerosol dispersal is not completely prevented by Using high-volume

suction and dental dam.

4. How many of dental clinics follow the exact IAQ preventive instructions?

5. Air conditioners make the air dryer (higher risk of droplet nuclei formation

because of fluctuating humidity levels)

Page 5: Indoor Air Quality Assurance In A Dental Environment.Dental.presentation ( october 2012) by somamedical.net

Why is I.A.Q important in a

dental environment?The execution of dental work and the use of various chemical compounds leads to

exposure levels for dentists, staff and patients to a range of potentially harmful airborne

contaminants. Especially for dental staff this exposure to potentially harmful air pollutants

can be significantly higher than that of individuals in most indoor environments.

Microorganisms

The use of high-speed drills and ultrasonic scaling equipment generates fine droplets which

are light enough to stay airborne for hours. Bacteria and viruses, which are contained in

these micro-droplets, are easily inhaled and constitute a potential source of infection.

Mercury

Numerous studies show that dentists and their staff have higher than average levels of

inorganic mercury (Hg) in their blood and urine. Mercury vapours can be released by the

placement and the removal of amalgam fillings. They may also be released from indoor

surfaces, where they may have accumulated over years of usage.

Disinfectants

Chemical disinfectants in a dental environment are responsible for a generally unpleasant

odour. Some disinfectants may also cause irritation and may have a sensitising potential

especially for staff.

Page 6: Indoor Air Quality Assurance In A Dental Environment.Dental.presentation ( october 2012) by somamedical.net

Journal- ExtractIndoor air quality in a dentistry clinic.Helmis CG, Tzoutzas J, Flocas HA, Halios CH, Stathopoulou OI, Assimakopoulos VD, Panis V, Apostolatou M, Sgouros

G, Adam E.

Source

Division of Applied Physics, Department of Physics, University of Athens, University Campus, Build.Phys-5, Athens 157 84,

Greece. [email protected] <[email protected]>

Abstract

The purpose of this work is to assess, both experimentally and theoretically the status of air quality in a dentistry clinic of the

Athens University Dentistry Faculty with respect to chemical pollutants and identify the indoor sources associated with dental

activities. Total VOCs, CO(2), PM(10), PM(2.5), NO(x) and SO(2) were measured over a period of approximately three months

in a selected dentistry clinic. High pollution levels during the operation hours regarding CO(2), total VOCs andParticulate Matter were found, while in the non-working periods lower levels were recorded. On the contrary, NO(x) and

SO(2) remained at low levels for the whole experimental period. These conditions were associated with the number ofoccupants, the nature of the dental clinical procedures, the materials used and the ventilation schemes, which lead tohigh concentrations, far above the limits that are set by international organizations and concern human exposure. The indoor

environmental conditions were investigated using the Computational Fluid Dynamics (CFD) model PHOENICS for inert gases

simulation. The results revealed diagonal temperature stratification and low air velocities leading to pollution stratification,

accompanied by accumulation of inert gaseous species in certain areas of the room. Different schemes of natural ventilation

were also applied in order to examine their effect on the indoor comfort conditions for the occupants, in terms of air renewal and

double cross ventilation was found to be most effective. The relative contribution of the indoor sources, which are mainly

associated with indoor activities, was assessed by application of the Multi Chamber Indoor Air Quality Model (MIAQ) to the

experimental data. It was found that deposition onto indoor surfaces is an important removal mechanism while a greatamount of particulate matter emitted in the Clinic burdened severely the indoor air quality. The natural ventilation of the

room seemed to reduce the levels of the fine particles. The emission rates for the fine and coarse particulates were found to be

almost equal, while the coarse particles were found susceptible to deposition onto indoor surfaces.

PMID:

17434576 [PubMed - indexed for MEDLINE]

Page 7: Indoor Air Quality Assurance In A Dental Environment.Dental.presentation ( october 2012) by somamedical.net

The Dental I.A.Q. Solutions

Temporary Solutions:

Using of disinfectants on surfaces. (Time

consuming and costly )

Long-lasting preventive solutions :

Slow releasing active chemicals (Titanium

Dioxide, TiO2), air filters, UV-C light and

negative ions.

Page 8: Indoor Air Quality Assurance In A Dental Environment.Dental.presentation ( october 2012) by somamedical.net

Legend:

Titanium

Dioxide

Cleanature

SM767B

Uvmax

SM212

Medilite GFL

Page 9: Indoor Air Quality Assurance In A Dental Environment.Dental.presentation ( october 2012) by somamedical.net

So what is IAQ ?

Indoor Air Quality as defined by OSHA Malaysia,

OSHA Singapore and ASHRAE standard 62-1989.

“Wherein it is stated that air in which there are

no known contaminants at harmful

concentrations”. So quality air is always related

to fresh air.

Page 10: Indoor Air Quality Assurance In A Dental Environment.Dental.presentation ( october 2012) by somamedical.net

3 main causes of IAQ problems

• Source of contamination

• Susceptible occupants

• Mechanism transport of contaminants

Page 11: Indoor Air Quality Assurance In A Dental Environment.Dental.presentation ( october 2012) by somamedical.net

Gases

� Volatile Organic Compounds (V.O.C).

� Potential VOC’s come from gases of building furnishings i.e. carpets,

furniture etc. and life cycle byproducts of micro-organism that lives in

the building (or its HVAC system).

� Aldehyde vapors are typical byproducts of both off gassing and

chemical processes, that occur inside or outside the building.

Particles

� Mostly counted in the diameter range from 0.1 micron or greater.

� Bio-aerosol are defined as airborne particles, which are living

organisms, spores and fragments of organisms released from living

organisms.

� These include pathogens (disease causing viruses), fungi (mold) and

bacteria.

Type of IAQ contaminants

Page 12: Indoor Air Quality Assurance In A Dental Environment.Dental.presentation ( october 2012) by somamedical.net

What I.A.Q problems should we be

concerned about?

1. How can people eject flu viruses into the air.

2. What different forms can airborne viruses take.

3. How far can those viruses travel & how can theycirculate within buildings and inside their HVACunits.

4. What conditions increase airborne flu virussurvival.

5. What systems are available to sterilize, captureand/or kill airborne flu viruses.

Page 13: Indoor Air Quality Assurance In A Dental Environment.Dental.presentation ( october 2012) by somamedical.net

Airborne transmission depends on people to

launch viruses into the air. People can shed

this many flu virus into the air:

1. Coughing 3,000+

2. Sneezing 3,000+

3. Breathing 200+ natural sterilization , nose hair & mucus.

4. Talking/Singing 1,000+

5. Vomiting 1,000+

6. Diarrhea *20,000+

Page 14: Indoor Air Quality Assurance In A Dental Environment.Dental.presentation ( october 2012) by somamedical.net

How far can Airborne Viruses Travel?

Large/Small Droplets Droplet Nuclei

1. Coughing 1-5 feet 160+ feet

2. Sneezing 8-15 feet 160+ feet

3. Singing, Talking 1-3 feet 160+ feet

4. Mouth Breathing 1-3 feet 160+ feet

5. Diarrhea* 5 feet+ 160+ feet

*As a result of toilet water aerosolization, air contamination in toilets

need to be effectively sterilized and contained.

Page 15: Indoor Air Quality Assurance In A Dental Environment.Dental.presentation ( october 2012) by somamedical.net

Stages of Infectious Droplets

& Droplet Nuclei

Page 16: Indoor Air Quality Assurance In A Dental Environment.Dental.presentation ( october 2012) by somamedical.net

Infectious Droplets & Droplet

Nuclei Travel Lengths

Page 17: Indoor Air Quality Assurance In A Dental Environment.Dental.presentation ( october 2012) by somamedical.net

Droplet Nuclei Viruses are 0.3μ or less, it can

penetrate deeply into the human lungs

A μm is a micron or 1/1,000,000 of a meter.

The smallest particle you can see is 30μm.

Page 18: Indoor Air Quality Assurance In A Dental Environment.Dental.presentation ( october 2012) by somamedical.net

Let’s not forget the detrimental effects of swine

flu!

Page 19: Indoor Air Quality Assurance In A Dental Environment.Dental.presentation ( october 2012) by somamedical.net

How do Occupant Droplet Nuclei travel both within indoor

spaces and then throughout a building?

Source

Page 20: Indoor Air Quality Assurance In A Dental Environment.Dental.presentation ( october 2012) by somamedical.net

So, is there a flu season?

Does flu take a vacation?

Why are there flu epidemics?

Page 21: Indoor Air Quality Assurance In A Dental Environment.Dental.presentation ( october 2012) by somamedical.net

The answer is found in

HUMIDITY LEVELS

Page 22: Indoor Air Quality Assurance In A Dental Environment.Dental.presentation ( october 2012) by somamedical.net

Optimum Humidity

For optimum air quality, Indoor Relative Humidity should always be

maintained between 40% and 60%!

Page 23: Indoor Air Quality Assurance In A Dental Environment.Dental.presentation ( october 2012) by somamedical.net

Low indoor humidity increases

Droplet Nuclei Levels

• Viruses evaporate faster in low humidity levelsthus creating More Droplet Nuclei.

• Low humidity allows droplet nuclei to stayairborne longer as the droplets do not absorbwater weight which would cause them to fall tothe ground.

• Indoor Air currents both created by HVACsystems and people movement assure thatdroplet nuclei will remain airborne Indefinitely.

• This allows HVAC systems to remove andredistribute droplet nuclei throughout thebuilding to infect more occupants.

Page 24: Indoor Air Quality Assurance In A Dental Environment.Dental.presentation ( october 2012) by somamedical.net

So, is there a solution to resolve

I.A.Q.A problem?

Page 25: Indoor Air Quality Assurance In A Dental Environment.Dental.presentation ( october 2012) by somamedical.net

Yes!According to Environmental Protection Agency

These are the recommended technologies

According to EPA guidelines…

1. MERV (Minimum Efficiency Reporting Value) Rated Filters

(H.E.P.A)

2. Germicidal UV Lights (UV-C)

3. Magnetized Air Media Filtration (ELECTROSTATIC FILTERS)

4. Bi-Polar Ionization (GERMICIDAL MEDICAL LAMP)

5. Photo-Catalytic Oxidation (NANO TiO2)

Page 26: Indoor Air Quality Assurance In A Dental Environment.Dental.presentation ( october 2012) by somamedical.net

UVC

Electrostatic

filter

24/7 IAQA

solution

Protocol

MERV

Bi-polar

Ionization

Photo-

catalyst

So in essence, if we follow all five sterilization recommended by

EPA, we would effectively have a 24/7 sterilization solution

protocol

Page 27: Indoor Air Quality Assurance In A Dental Environment.Dental.presentation ( october 2012) by somamedical.net

Lets explore and understand each of

the 5 technologies recommended by

Environmental Protection Agency

(EPA)

Page 28: Indoor Air Quality Assurance In A Dental Environment.Dental.presentation ( october 2012) by somamedical.net

1. MERV (Minimum Efficiency Reporting

Value) Rated Filters (H.E.P.A)

• Particulate matter contain pathogens (viruses,

bacteria and infectious organisms), allergens and

carcinogens.

• Mechanical air filters, like High Efficiency Particulate

Air (HEPA) filters, remove 99.97% of all airborne

particulates of 0.3 microns and above in size.

• They trap the particles in filters made out of tightly

woven fibers.

Page 29: Indoor Air Quality Assurance In A Dental Environment.Dental.presentation ( october 2012) by somamedical.net

2.Germicidal UV Lights (UV-C)

• UV-C light emits germicidal wavelengths

between 200-300nm. This reacts with the

DNA and permanently alters the structure and

the molecular bonds of microbiological

contaminants such as bacteria, viruses, germs,

molds and mildews.

How does UV-C Work?

Page 30: Indoor Air Quality Assurance In A Dental Environment.Dental.presentation ( october 2012) by somamedical.net

Its scientifically proven that Ultraviolet Germicidal

lamps (UVC) working at 253.7 nanometers at the

correct intensity can effectively prevent cross

contamination of the following airborne diseases:-

• Aspergillosis Niger

• Legionella

• SARS

• Bacillus Anthracis

• Dust Mites

• Allergy & Sinusitis

• Tuberculosis (TB)

• H1N1

Page 31: Indoor Air Quality Assurance In A Dental Environment.Dental.presentation ( october 2012) by somamedical.net

UV dosage for the inactivation of various microbes

Bacteria UV Dose Bacteria UV Dose

Agrobacterium lumefaciens 5 8,500 Pseudomonas aeruginosa (Environ.Strain) 1,2,3,4,5,9

10,500

Bacillus anthracis 1,4,5,7,9 (anthrax veg.) 8,700 Pseudomonas aeruginosa (Lab. Strain) 5,7 3,900

Bacillus anthracis Spores (anthrax spores)* 46,200 Pseudomonas fluorescens 4,9 6,600

Bacillus megatherium Sp. (veg) 4,5,9 2,500 Rhodospirillum rubrum 5 6,200

Bacillus megatherium Sp. (spores) 4,9 5,200 Salmonella enteritidis 3,4,5,9 7,600

Bacillus paratyphosus 4,9 6,100 Salmonella paratyphi (Enteric Fever) 5,7 6,100

Bacillus subtilis 3,4,5,6,9 11,000 Salmonella Species 4,7,9 15,200

Bacillus subtilis Spores 2,3,4,6,9 22,000 Salmonella typhimurium 4,5,9 15,200

Clostridium tetani 23,100 Salmonella typhi (Typhoid Fever) 7 7,000

Clostridium botulinum 11,200 Salmonella 10,500

Corynebacterium diphtheriae 1,4,5,7,8,9 6,500 Sarcina lutea 1,4,5,6,9 26,400

Dysentery bacilli 3,4,7,9 4,200 Serratia marcescens 1,4,6,9 6,160

Eberthella typhosa 1,4,9 4,100 Shigella dysenteriae - Dysentery 1,5,7,9 4,200

Escherichia coli 1,2,3,4,9 6,600 Shigella flexneri - Dysentery 5,7 3,400

Legionella bozemanii 5 3,500 Shigella paradysenteriae 4,9 3,400

Legionella dumoffill 5 5,500 Shigella sonnei 5 7,000

Legionella gormanil 5 4,900 Spirillum rubrum 1,4,6,9 6,160

Legionella micdadei 5 3,100 Staphylococcus albus 1,6,9 5,720

Legionella longbeachae 5 2,900 Staphylococcus aureus (incl. MRSA) 3,4,6,9 6,600

Legionella pneumophila (Legionnaire's Disease) 12,300 Staphylococcus epidermidis 5,7 5,800

Leptospira canicola-Infectious Jaundice 1,9 6,000 Streptococcus faecaila 5,7,8 10,000

Leptospira interrogans 1,5,9 6,000 Streptococcus hemolyticus 1,3,4,5,6,9 5,500

Sourced from: Centre for Disease Control (CDC) & World Health Organization (WHO)

Page 32: Indoor Air Quality Assurance In A Dental Environment.Dental.presentation ( october 2012) by somamedical.net

Micrococcus candidus 4,9 12,300 Streptococcus lactis 1,3,4,5,6 8,800

Micrococcus sphaeroides 1,4,6,9 15,400 Streptococcus pyrogenes 4,200

Mycobacterium tuberculosis 1,3,4,5,7,8,9 10,000 Streptococcus salivarius 4,200

Neisseria catarrhalis 1,4,5,9 8,500 Streptococcus viridans 3,4,5,9 3,800

Phytomonas tumefaciens 1,4,9 8,500 Vibrio comma (Cholera) 3,7 6,500

Proteus vulgaris 1,4,5,9 6,600 Vibrio cholerae 1,5,8,9 6,500

Molds UV Dose Molds UV Dose

Penicillium expansum 1,4,5,6,9 22,000 Oospora lactis 1,3,4,6,9 11,000

Penicillium roqueforti 1,2,3,4,5,6 26,400 Penicillium chrysogenum 56,000

Mucor racemosus (A & B) 1,3,4,6,9 35,200

Protozoa UV Dose Protozoa UV Dose

Chlorella vulgaris (algae) 1,2,3,4,5,9 22,000 Nematode Eggs 6 40,000

Virus UV Dose Virus UV Dose

Adeno Virus Type III 3 4,500 Influenza 1,2,3,4,5,7,9 6,600

Bacteriophage 1,3,4,5,6,9 6,600 Rotavirus 5 24,000

Coxsackie 6,300 Infectious Hepatitis 1,5,7,9 8,000

Yeasts UV Dose Yeasts UV Dose

Baker's Yeast 1,3,4,5,6,7,9 8,800 Saccharomyces cerevisiae 4,6,9 13,200

Brewer's Yeast 1,2,3,4,5,6,9 6,600 Saccharomyces ellipsoideus 4,5,6,9 13,200

Common Yeast Cake 1,4,5,6,9 13,200 Saccharomyces sp. 2,3,4,5,6,9 17,600

Dosage table continued….

Page 33: Indoor Air Quality Assurance In A Dental Environment.Dental.presentation ( october 2012) by somamedical.net

3. Magnetized Air Media Filtration

(ELECTROSTATIC FILTERS)

• Electrostatic air precipitators use a process called

electrostatic attraction to trap charged particles.

• They draw air through an ionization section where

particles obtain an electrical charge.

• The charged particles then accumulate on a series of

Flat plates called collectors that are oppositely

charged.

Page 34: Indoor Air Quality Assurance In A Dental Environment.Dental.presentation ( october 2012) by somamedical.net

4. Bi-Polar Ionization (Medilites)• Air ion generators, or ionizers disperse negatively charged ions

(anions) into the air, similar to the electronic air cleaners but

without a collector plate.

• These ions attach to airborne particles, making them heavier

and causing them to settle on the ground faster, away from

the nasal breathing zone.

• Negatively charged oxygen molecules will behave like hydroxyl

radicals to neutralize odors and destroy the DNA of pathogens

and allergens.

• Studies have shown that anions can freshen indoor air, reduce

tiredness, relieve stress, alleviate affective depression,

reinforce collagen, and strengthen the functions of autonomic

nerves and the immune system.

Page 35: Indoor Air Quality Assurance In A Dental Environment.Dental.presentation ( october 2012) by somamedical.net

5. Photo-Catalytic Oxidation

-NANO Titanium Dioxide (TiO2)

• Nano Titanium Dioxide (TiO2) transforms biological

and gaseous pollutants into harmless products by a

process called photo catalytic oxidation (PCO).

• When applied as a coating and exposed to ultra-

violet or ambient light, Nano-TiO2 produces hydroxyl

radicals and superoxide ions that will neutralize

biological and gaseous contaminants in indoor air.

Page 36: Indoor Air Quality Assurance In A Dental Environment.Dental.presentation ( october 2012) by somamedical.net

• We now know IAQA problems exist!

• We now understand the

recommendations by EPA for effective

sterilization!

• So, what kind of equipments and

technologies does Soma Medical have to

resolve these IAQA problems?

Page 37: Indoor Air Quality Assurance In A Dental Environment.Dental.presentation ( october 2012) by somamedical.net

Benefits

• Cost efficient

• Long lasting

• Low maintenance

• Good indoor air quality

Page 38: Indoor Air Quality Assurance In A Dental Environment.Dental.presentation ( october 2012) by somamedical.net

Cleanature SM767A

Ultraviolet light (UVC)

MERV filter + TiO2

Bipolar ionization

Electrostatic

All 5 EPA recommended

solutions.

Page 39: Indoor Air Quality Assurance In A Dental Environment.Dental.presentation ( october 2012) by somamedical.net

Medilite GFL

Bipolar ionization

TiO2

Page 40: Indoor Air Quality Assurance In A Dental Environment.Dental.presentation ( october 2012) by somamedical.net

Medilite GML

Bipolar ionization

TiO2

Page 41: Indoor Air Quality Assurance In A Dental Environment.Dental.presentation ( october 2012) by somamedical.net

UVmaxTM Series

Ultraviolet light (UVC) for

various applications

UvmaxTM SM14-H

UvmaxTM SMT8

UvmaxTM SM40W

UvmaxTM SM14

UvmaxTM SM313

UvmaxTM SM212

Page 42: Indoor Air Quality Assurance In A Dental Environment.Dental.presentation ( october 2012) by somamedical.net

Customized UVC Series

Ultraviolet light (UVC) for

projects based applications

Double Ended UVC

Single Ended UVC

UVC SM15C Submersible UVC

Page 43: Indoor Air Quality Assurance In A Dental Environment.Dental.presentation ( october 2012) by somamedical.net

SM Nano 1152 Titanium Dioxide

Page 44: Indoor Air Quality Assurance In A Dental Environment.Dental.presentation ( october 2012) by somamedical.net

The proof is in the pudding!!

Our recommended sterilization

solution protocol and products

can be effectively tested through a

pre and post microbial challenge

test, VOC count test and

particulate testing

Page 45: Indoor Air Quality Assurance In A Dental Environment.Dental.presentation ( october 2012) by somamedical.net

Our equipments used for testing

Particle Scanner

IAQA VOC Tester

Negative Ion Tester

Page 46: Indoor Air Quality Assurance In A Dental Environment.Dental.presentation ( october 2012) by somamedical.net

The importance of testing for

Volatile organic compounds (VOC)

Volatile organic compounds (VOCs) refers

to organic chemical compounds which have

significant vapor pressures and can affect the

environment and human health.

Page 47: Indoor Air Quality Assurance In A Dental Environment.Dental.presentation ( october 2012) by somamedical.net

The importance of testing for

negative ions

Negative ions help freshen and purify the air by

neutralizing allergens such as pollen, mold

spores, dust, and animal dander floating in the

air. Negative ions will cause floating particulates

to be attracted and stick to each other, forming

'clumps', this eventually falls to the ground and

thus purifies the air.

Page 48: Indoor Air Quality Assurance In A Dental Environment.Dental.presentation ( october 2012) by somamedical.net

The importance of testing for

Particulate count

Particle counters are used to determine the airquality by counting and sizing the number ofparticles in the air. This information is useful indetermining the concentration and micron size ofparticulates since it has a direct relationship tohuman well being and IAQA.

Page 49: Indoor Air Quality Assurance In A Dental Environment.Dental.presentation ( october 2012) by somamedical.net

Class

maximum particles/m³ FED STD

209E

equivalent≥0.1 µm ≥0.2 µm ≥0.3 µm ≥0.5 µm ≥1 µm ≥5 µm

ISO 1 10 2

ISO 2 100 24 10 4

ISO 3 1,000 237 102 35 8 Class 1

ISO 4 10,000 2,370 1,020 352 83 Class 10

ISO 5 100,000 23,700 10,200 3,520 832 29 Class 100

ISO 6 1,000,000 237,000 102,000 35,200 8,320 293 Class 1000

ISO 7 352,000 83,200 2,930Class

10,000

ISO 8 3,520,000 832,000 29,300Class

100,000

ISO 9 35,200,000 8,320,000 293,000 Room air

ISO 14644-1 clean room standards

Sourced from: http://en.wikipedia.org/wiki/Cleanroom