IMPEDANCE AUDIOMETRYAditya Ghosh RoyPGT2MS ENT
![Page 2: Impedance audiometry part 1](https://reader034.fdocuments.net/reader034/viewer/2022042423/58ac0d4b1a28ab33178b4eeb/html5/thumbnails/2.jpg)
IMPEDANCE AUDIOMETRY
•USE
• TESTTYMPANOMETRY
EUSTACHIAN TUBE FUNCTIONSTAPEDIAL
REFLEX
![Page 3: Impedance audiometry part 1](https://reader034.fdocuments.net/reader034/viewer/2022042423/58ac0d4b1a28ab33178b4eeb/html5/thumbnails/3.jpg)
SOUND WAVE
SOUND WAVESOLID
RELECTED SOUND
WAVE
AIR
AIR
ABSORBED SOUND
![Page 4: Impedance audiometry part 1](https://reader034.fdocuments.net/reader034/viewer/2022042423/58ac0d4b1a28ab33178b4eeb/html5/thumbnails/4.jpg)
SOUNDAIR
SOLIDREFLECTED SOUND
IMPEDANCE
STIFFNES
S
MASS
FRICTION
![Page 5: Impedance audiometry part 1](https://reader034.fdocuments.net/reader034/viewer/2022042423/58ac0d4b1a28ab33178b4eeb/html5/thumbnails/5.jpg)
IMPEDANCE
AIR
COCHLEA
SOUNDMIDDLE EAR IMPEDANCE MATCHING
DEVICE
COCHLEA
EAC
TM
![Page 6: Impedance audiometry part 1](https://reader034.fdocuments.net/reader034/viewer/2022042423/58ac0d4b1a28ab33178b4eeb/html5/thumbnails/6.jpg)
TYMPANOMETRY (DEF)
• CHANGE IN PRESSURE --- CHANGE IN TM STIFFNESS ---SOUND ENERGY REFLECTED BACK DEPENDS ON STIFFNESS OF TM OR PRESSURE CHANGE
PROBE TONE AMPLIFIER
MANOMETER
SOUND
TYMPANIC MEMBRANE
REFLECTED
SOUND
PRESSURE
![Page 7: Impedance audiometry part 1](https://reader034.fdocuments.net/reader034/viewer/2022042423/58ac0d4b1a28ab33178b4eeb/html5/thumbnails/7.jpg)
• THEREFORE TYMPANOMETRY MAY BE DEFINED AS MEASUREMENT OF CHANGE IN IMPEDANCE OF MIDDLE EAR CAVITY AT THE TM PLANE IN RELATION TO CHANGE IN PRESSURE IN EAC.
• TYMPANOGRAM
Y or ORDINATEIMPEDANCE OR
STIFFNESS
X OR ABSCISSAAIR PRESSURE
![Page 8: Impedance audiometry part 1](https://reader034.fdocuments.net/reader034/viewer/2022042423/58ac0d4b1a28ab33178b4eeb/html5/thumbnails/8.jpg)
• IMPEDANCE
• NONE OF THE PARAMETERS MEASURED INDIVIDUALLY
SO AS A RESULT ACOUSTIC ADMITTANCE IS MEASUREDADMITTANCE IS RECIPROCAL OF IMPEDANCE
STIFFNESSMASS
FRICTION
IMPEDANCEOPPOSITION TO FLOW OF
ENERGYACOUSTIC OHM
ADMITTANCEEASE TO FLOW OF ENERGY
ACOUSTIC MHO
![Page 9: Impedance audiometry part 1](https://reader034.fdocuments.net/reader034/viewer/2022042423/58ac0d4b1a28ab33178b4eeb/html5/thumbnails/9.jpg)
• AUDIOMETERS STILL AUDIOMETERS DO NOT MEASURE ADMITTANCE DIRECTLY COMPLIANCE
LOW FREQUENCY PROBE TONE USED IMPEDANCE
EASE OF MOVEMENT OR SPRINGINESS OF MIDDLE EAR SYSTEM
IS ALSO RECIPROCAL OF STIFFNESS
![Page 10: Impedance audiometry part 1](https://reader034.fdocuments.net/reader034/viewer/2022042423/58ac0d4b1a28ab33178b4eeb/html5/thumbnails/10.jpg)
• HENCE IF COMPLIANCE IS MEASURED USING LOW FREQUENCY TONE
• IMPEDANCE OF MIDDLE EAR SYSTEM
• MOST OF THE IMPEDANCE AUDIOMETERS MEASURE COMPLIANCE
![Page 11: Impedance audiometry part 1](https://reader034.fdocuments.net/reader034/viewer/2022042423/58ac0d4b1a28ab33178b4eeb/html5/thumbnails/11.jpg)
IMPORTANT POINTS
• C1 – COMPLIANCE VALUE AT +200mm water
• C2 – COMPLIANCE VALUE AT (MAXIMUM)
• CX – STATIC COMPLIANCE (C2- C1=CX)
STATIC COMPLIANCE IS DEFINED AS COMPLIANCE OF AUDITORY CONDUCTIVE PATHWAY AT TM.
![Page 12: Impedance audiometry part 1](https://reader034.fdocuments.net/reader034/viewer/2022042423/58ac0d4b1a28ab33178b4eeb/html5/thumbnails/12.jpg)
MIDDLE EAR PRESSURE
• PRESSURE AT WHICH COMPLIANCE VALUE IS MAXIMUM IS CALLED AS MIDDLE EAR PRESSURE IE PRESSURE OF AIR IN MIDDLE EAR CAVITY.
![Page 13: Impedance audiometry part 1](https://reader034.fdocuments.net/reader034/viewer/2022042423/58ac0d4b1a28ab33178b4eeb/html5/thumbnails/13.jpg)
PHYSICAL VOLUME TEST VALUE
THE COMPLIANCE VALUE AT +200mM water IS THE VOLUME OF EAC .
![Page 14: Impedance audiometry part 1](https://reader034.fdocuments.net/reader034/viewer/2022042423/58ac0d4b1a28ab33178b4eeb/html5/thumbnails/14.jpg)
TYMPANOMETRY
MEASUREMENT OF STATIC
COMPLIANCE
MEASUREMENT OF MIDDLE EAR PRESSURE
![Page 15: Impedance audiometry part 1](https://reader034.fdocuments.net/reader034/viewer/2022042423/58ac0d4b1a28ab33178b4eeb/html5/thumbnails/15.jpg)
MEASUREMENT OF STATIC COMPLIANCE
• cc/ ml if COMPLIANCE• Millimho if SUSPECTANCE
• IF A 220 Hz PROBE– 1MILLIMHO OF SUSPECTANCE = 1 CC/ML OF COMPLIANCE
TYMPANOGRAM
ABSOLUTE
RELATIVE
COMPENSATED
![Page 16: Impedance audiometry part 1](https://reader034.fdocuments.net/reader034/viewer/2022042423/58ac0d4b1a28ab33178b4eeb/html5/thumbnails/16.jpg)
• BASELINE IS COMPLIANCE AT +200
• SHADED AREA IS VOLUME OF EAC
• ALSO CALLED NON COMPENSATED TYPE
ABSOLUTE
• BASELINE IS 0 AT ORDINATE• BRACKET PORTION IS
COMPLIANCE
RELATIVE
• BASELINE IS 0 AT ORDINATE• BRACKET PORTION IS
COMPLIANCE• SHADED AREA BESIDE THE
TYMPANOGRAM IS VOLUME OF EAC
COMPENSATED
![Page 17: Impedance audiometry part 1](https://reader034.fdocuments.net/reader034/viewer/2022042423/58ac0d4b1a28ab33178b4eeb/html5/thumbnails/17.jpg)
• NORMAL RANGE COMPLIANCE
• IMP POINT– CLINICAL CONDITION OF TM TO BE ALWAYS NOTED
• STUDY BY A.S. FELDMAN– HEALED TM INVALIDATES COMPLIANCE AS ONE OF THE TESTS OF TYMPANOMETRY
.35 TO 1.40 ML
>2.50mL
<.28 mL
AB
NO
RMAL
LY
HIG
H
ABNO
RMALL
Y LOW
![Page 18: Impedance audiometry part 1](https://reader034.fdocuments.net/reader034/viewer/2022042423/58ac0d4b1a28ab33178b4eeb/html5/thumbnails/18.jpg)
LARGE TM
OSSICULAR DISCONTINUITY
SCARED/HEALED TM
POST STAPEDECTOMY EAR
OTITIS MEDIA WITH EFFUSION
OSSICULAR FIXATION
TYMPANOSCLEROSIS
OTOSCLEROSIS
TUMOUR OF MIDDLE EAR
![Page 19: Impedance audiometry part 1](https://reader034.fdocuments.net/reader034/viewer/2022042423/58ac0d4b1a28ab33178b4eeb/html5/thumbnails/19.jpg)
MEASUREMENT OF MIDDLE EAR PRESSURE• EXPRESSED IN mm WATER / DEKA PASCAL
(daPa)
• 1mm WATER = 1.20 DEKA PASCAL
• RANGE = +50 TO -50 mm WATER
• MEP NEGATIVE WHEN P < -100 mm WATER
• PAED AGE GROUP-- +25 TO -100mm WATER
![Page 20: Impedance audiometry part 1](https://reader034.fdocuments.net/reader034/viewer/2022042423/58ac0d4b1a28ab33178b4eeb/html5/thumbnails/20.jpg)
NORMAL MEP• SCARRED TM• OSICULLAR FIXATION• OSICULLAR DISCONTUINITY• STAPEDIAL OTOSCLEROSISNEGATIVE MEP• ET DYSFUNCTION• SECRETORY OTITIS
MEDIA/EFFUSION
![Page 21: Impedance audiometry part 1](https://reader034.fdocuments.net/reader034/viewer/2022042423/58ac0d4b1a28ab33178b4eeb/html5/thumbnails/21.jpg)
ABSENCE OF PEAK• PERFORATED TM• ADHESIVE OTITIS MEDIA• ARTIFACT• PATENT GROMET IN TM• CERUMEN
POSITIVE MEP•EARLY ACUTE OTITIS MEDIA
![Page 22: Impedance audiometry part 1](https://reader034.fdocuments.net/reader034/viewer/2022042423/58ac0d4b1a28ab33178b4eeb/html5/thumbnails/22.jpg)
IMP POINT--POSITIVE PRESSURE PEAK
• SWALLOWING• CHILD CRYING PHYSIOLOGICAL• VALSALVA• HOLD BREATH IN EXPIRATION
• IN EARLY AOM PUS FORMED IN MEC AND ET DYSFUNCTION
DECREASE VOLUME + INCREASE PRESSURE OF MEC
POSITIVE PRESSURE PEAK
![Page 23: Impedance audiometry part 1](https://reader034.fdocuments.net/reader034/viewer/2022042423/58ac0d4b1a28ab33178b4eeb/html5/thumbnails/23.jpg)
TYPES AND SHAPES OF TYMPANOGRAMS
TYMPANOGRAMS
J. JERGER
A
B
A.S. FELDMAN
![Page 24: Impedance audiometry part 1](https://reader034.fdocuments.net/reader034/viewer/2022042423/58ac0d4b1a28ab33178b4eeb/html5/thumbnails/24.jpg)
TYPE A
• SHARP MAXIMUM AT 0 mm WATER• NORMAL EAR AND SOME CASES OF
OTOSCLEROSIS
![Page 25: Impedance audiometry part 1](https://reader034.fdocuments.net/reader034/viewer/2022042423/58ac0d4b1a28ab33178b4eeb/html5/thumbnails/25.jpg)
TYPE AD• NORMAL MIDDLE EAR PRESSURE WITH
HIGH COMPLIANCE• SEEN IN OSSICULAR CHAIN
DISCONTUINITY OR SCARRING OF TM• NOTCHED PEAK OR DOUBLE MAX AT 0
mm USUALLY SEEN WITH A HIGH FREQUENCY PROBE IN OSSICULAR DISCONTUINITY
![Page 26: Impedance audiometry part 1](https://reader034.fdocuments.net/reader034/viewer/2022042423/58ac0d4b1a28ab33178b4eeb/html5/thumbnails/26.jpg)
TYPE AS
• NORMAL MIDDLE EAR PRESSURE WITH LOW COMPLIANCE
• OTOSCLEROSIS AND THICKENED TM
![Page 27: Impedance audiometry part 1](https://reader034.fdocuments.net/reader034/viewer/2022042423/58ac0d4b1a28ab33178b4eeb/html5/thumbnails/27.jpg)
TYPE B
• FLAT TYMPANOGRAM• LITTLE OR NO COMPLIANCE AND NO SHARP PEAK• SEEN IN ADHESIVE OTITIS MEDIA, OTITIS MEDIA
WITH EFFUSION, PERFORATION OF TM
![Page 28: Impedance audiometry part 1](https://reader034.fdocuments.net/reader034/viewer/2022042423/58ac0d4b1a28ab33178b4eeb/html5/thumbnails/28.jpg)
TYPE C
• NEGATIVE MIDDLE EAR PRESSURE WITH NORMAL COMPLIANCE
• ET DYSFUNCTION WITHOUT EFFUSION
![Page 29: Impedance audiometry part 1](https://reader034.fdocuments.net/reader034/viewer/2022042423/58ac0d4b1a28ab33178b4eeb/html5/thumbnails/29.jpg)
TYPE CS
• NEGATIVE MIDDLE EAR PRESSURE WITH LOW COMPLIANCE• ET DYSFUNCTION WITH OTITIS MEDIA WITH EFFUSION
![Page 30: Impedance audiometry part 1](https://reader034.fdocuments.net/reader034/viewer/2022042423/58ac0d4b1a28ab33178b4eeb/html5/thumbnails/30.jpg)
CLASSIFICATION BY A.S. FELDMAN
PEAK PRESSURE
TYPE OF CONFIGURATION
OF TYMPANOGRAM
COMPLIANCE OR AMPLITUDE
![Page 31: Impedance audiometry part 1](https://reader034.fdocuments.net/reader034/viewer/2022042423/58ac0d4b1a28ab33178b4eeb/html5/thumbnails/31.jpg)
1.NORMAL TYMPANO GRAM• GOOD COMPLIANCE AND PEAK PRESSURE AT 0
mm WATER• CORRESPONDS TO JAGER TYPE A
![Page 32: Impedance audiometry part 1](https://reader034.fdocuments.net/reader034/viewer/2022042423/58ac0d4b1a28ab33178b4eeb/html5/thumbnails/32.jpg)
2.NORMAL MIDDLE EAR PRESSURE WITH HIGH COMPLIANCE • IF 226HZ PROBE USED THEN EITHER OSSICULAR
CHAIN DISCONTUINITY OR SCARRING OF TM• BUT IF A 660 OR 800 HZ PROBE USED THEN A
NOTCHED PEAK OR DOUBLE MAX AT 0 mm USUALLY SEEN IN OSSICULAR DISCONTUINITY
![Page 33: Impedance audiometry part 1](https://reader034.fdocuments.net/reader034/viewer/2022042423/58ac0d4b1a28ab33178b4eeb/html5/thumbnails/33.jpg)
3.NORMAL MIDDLE EAR PRESSURE WITH LOW COMPLIANCE• OTOSCLEROSIS OR OSSICULAR FIXATION AND
THICKENED TM
![Page 34: Impedance audiometry part 1](https://reader034.fdocuments.net/reader034/viewer/2022042423/58ac0d4b1a28ab33178b4eeb/html5/thumbnails/34.jpg)
4. FLAT TYMPANOGRAM• LITTLE OR NO COMPLIANCE AND NO SHARP PEAK• SEEN IN ADHESIVE OTITIS MEDIA, OTITIS MEDIA
WITH EFFUSION, PERFORATION OF TM .• CORRESPONDS TO JAGER TYPE B.
![Page 35: Impedance audiometry part 1](https://reader034.fdocuments.net/reader034/viewer/2022042423/58ac0d4b1a28ab33178b4eeb/html5/thumbnails/35.jpg)
5.NEGATIVE MIDDLE EAR PRESSURE WITH LOW COMPLIANCE• ET DYSFUNCTION WITH OTITIS MEDIA WITH
EFFUSION• CORRESPONDS TO JAGER TYPE CS
![Page 36: Impedance audiometry part 1](https://reader034.fdocuments.net/reader034/viewer/2022042423/58ac0d4b1a28ab33178b4eeb/html5/thumbnails/36.jpg)
6. POSITIVE MIDDLE EAR PRESSURE NORMAL COMPLIANCE• RARELY SEEN• IN EARLY AOM
IN EARLY AOM PUS FORMED IN MEC AND ET DYSFUNCTION
DECREASE VOLUME + INCREASE PRESSURE OF MEC
POSITIVE PRESSURE PEAK
![Page 37: Impedance audiometry part 1](https://reader034.fdocuments.net/reader034/viewer/2022042423/58ac0d4b1a28ab33178b4eeb/html5/thumbnails/37.jpg)
7.NEGATIVE MIDDLE EAR PRESSURE WITH NORMAL COMPLIANCE• ET DYSFUNCTION WITHOUT EFFUSION
![Page 38: Impedance audiometry part 1](https://reader034.fdocuments.net/reader034/viewer/2022042423/58ac0d4b1a28ab33178b4eeb/html5/thumbnails/38.jpg)
TO SUMMARISE
![Page 39: Impedance audiometry part 1](https://reader034.fdocuments.net/reader034/viewer/2022042423/58ac0d4b1a28ab33178b4eeb/html5/thumbnails/39.jpg)
TO BE CONT..