IFB #PW17-6, Addendum #1, Exhibit G, Page 1 of 4...APPROVED NFPA 13 FIRE SPRINKLER PROTECTION,...

4
EX EXTERIOR PATH OF TRAVEL EGRESS PATH OF TRAVEL EX = EXTERIOR EXIT EE = EXIT ENCLOSURE EP = EXIT PASSAGEWAY EGRESS LEGEND NOTES: 1. ALL EXISTING EXITS SHALL REMAIN ACCESSIBLE DURING CONSTRUCTION FEC FIRE EXTINGUISHER CABINET (E) FLOOR AREA W/ NFPA 13 FIRE SPINKLERS (N) FLOOR AREA W/ NFPA 13 FIRE SPINKLERS FHC FIRE HOSE CABINET COMMON PATH OF TRAVEL 26' 6 EX EE 190 EX 16 EX 190 EGRESS FROM FLOORS ABOVE EGRESS FROM FLOORS ABOVE UP UP EE 2 DASHED LINE IS OUTLINE OF BLDG ABOVE AT FIRST FLOOR FHC FHC FEC FHC FHC AREA LIGHT SHADED IS (E) NFPA 13 FIRE SPRINKLERED 75 FT RADIUS FOR FEC/FHC COVERAGE TYP EX 25 EX 24 EX 33 AREA SHADED TO BE PROVIDED WITH (N) NFPA 13 FIRE SPRINKLER SYSTEM TYP- (SPACES ARE B OCCUPANCY UON) A-3 A-3 A-3 14' 45' 45' 46' 28' 43' EX 35 PROVIDE NEW NFPA 13 FIRE SPRINKLER PROTECTION FOR ALL NEW AND EXISTING SPACES IN THE BASEMENT THAT DO NOT CURRENTLY HAVE FIRE SPRINKLERS (SEE DIAGRAM BELOW). CONNECT TO THE EXISTING FIRE PROTECTION SERVICE MAINS AND PROVIDE NEW ZONE CONTROLS VALVES. AT EXISTING BASEMENT SPACES WITH 1974 APPROVED NFPA 13 FIRE SPRINKLER PROTECTION, UPGRADE ALL COMPONENTS TO CURRENT 2016 NFPA 13 FIRE SPRINKLER PROTECTION. 11 EX EE 79 EX 16 EX 79 EGRESS FROM FLOORS ABOVE EGRESS FROM FLOORS ABOVE UP UP EE 2 DASHED LINE IS OUTLINE OF BLDG ABOVE AT FIRST FLOOR FHC FHC FHC FHC AREA LIGHT SHADED IS (E) NFPA 13 FIRE SPRINKLERED 75 FT RADIUS FOR FEC/FHC COVERAGE TYP PROVIDE NEW NFPA 13 FIRE SPRINKLER PROTECTION FOR ALL NEW AND EXISTING SPACES IN THE BASEMENT THAT DO NOT CURRENTLY HAVE FIRE SPRINKLERS (SEE DIAGRAM BELOW). CONNECT TO THE EXISTING FIRE PROTECTION SERVICE MAINS AND PROVIDE NEW ZONE CONTROLS VALVES. AT EXISTING BASEMENT SPACES WITH 1974 APPROVED NFPA 13 FIRE SPRINKLER PROTECTION, UPGRADE ALL COMPONENTS TO CURRENT 2016 NFPA 13 FIRE SPRINKLER PROTECTION. N E R L E W A A T A S T E O F L R N F I O I A R L S C I E N A E D T E T H C I C 9 1 - - 5 31 C-15467 S H N O S. J E Z U A R C HUMBOLDT STATE UNIVERSITY Library - Seismic Renovations Arcata, California Owner: Trustees of the California State University Project Team Project Revisions Sheet Name Date Owner # SKA # Sheet Number Seals Arch: Suarez - Kuehne Architecture San Francisco, CA 94116 Struct: Thornton Tomasetti San Francisco, CA 94108 MEPT: Interface Engineering San Francisco, CA 94105 Acoust: Papadimos Group San Francisco, CA 94104 Civil: Stover Engineering Crescent City, CA 95531 Land: Genevieve Schmidt - Landscape Design McKinleyville, CA 95521 Cost: Construction Cost Management Services Oakland, CA 94612 A0.2 JUNE 8, 2018 EGRESS DIAGRAMS 1" = 20'-0" 2 LEVEL BASEMENT - EGRESS PLAN PROPOSED PROJECT NORTH NORTH 1" = 20'-0" 1 LEVEL BASEMENT - EGRESS PLAN EXISTING PROJECT NORTH NORTH 1 OWNER REV JUN 26, 2018 1 1 1 1 IFB #PW17-6, Addendum #1, Exhibit G, Page 1 of 4

Transcript of IFB #PW17-6, Addendum #1, Exhibit G, Page 1 of 4...APPROVED NFPA 13 FIRE SPRINKLER PROTECTION,...

Page 1: IFB #PW17-6, Addendum #1, Exhibit G, Page 1 of 4...APPROVED NFPA 13 FIRE SPRINKLER PROTECTION, UPGRADE ALL COMPONENTS TO CURRENT 2016 NFPA 13 FIRE SPRINKLER PROTECTION. N E R L EWA

EX

EXTERIOR PATH OF TRAVEL

EGRESS PATH OF TRAVEL

EX = EXTERIOR EXITEE = EXIT ENCLOSUREEP = EXIT PASSAGEWAY

EGRESS LEGEND

NOTES:1. ALL EXISTING EXITS SHALL REMAIN ACCESSIBLE

DURING CONSTRUCTION

FEC FIRE EXTINGUISHER CABINET

(E) FLOOR AREA W/ NFPA 13 FIRE SPINKLERS

(N) FLOOR AREA W/ NFPA 13 FIRE SPINKLERS

FHC FIRE HOSE CABINET

COMMON PATH OF TRAVEL26'

6

EX

EE

190 EX

16

EX 190

EGRESS FROM FLOORS ABOVE

EGRESS FROM FLOORS ABOVE

UP

UP

EE

2

DASHED LINE IS OUTLINE OF BLDG ABOVE AT FIRST FLOOR

FHC

FH

C

FE

C

FHC

FH

C

AREA LIGHT SHADED IS (E) NFPA 13 FIRE SPRINKLERED

75 FT RADIUS FOR FEC/FHC COVERAGE TYP

EX

25E

X

24

EX

33

AREA SHADED TO BE PROVIDED WITH (N) NFPA 13 FIRE SPRINKLER SYSTEM TYP-(SPACES ARE B OCCUPANCY UON)

A-3

A-3

A-3

14'

45'

45'

46'28'

43'

EX35

PROVIDE NEW NFPA 13 FIRE SPRINKLER PROTECTION FOR ALL NEW AND EXISTING SPACES IN THE BASEMENT THAT DO

NOT CURRENTLY HAVE FIRE SPRINKLERS (SEE DIAGRAM BELOW). CONNECT TO THE EXISTING FIRE PROTECTION

SERVICE MAINS AND PROVIDE NEW ZONE CONTROLS VALVES. AT EXISTING BASEMENT SPACES WITH 1974

APPROVED NFPA 13 FIRE SPRINKLER PROTECTION, UPGRADE ALL COMPONENTS TO CURRENT 2016 NFPA 13 FIRE

SPRINKLER PROTECTION.

11

EX

EE

79 EX

16

EX 79

EGRESS FROM FLOORS ABOVE

EGRESS FROM FLOORS ABOVE

UP

UP

EE

2

DASHED LINE IS OUTLINE OF BLDG ABOVE AT FIRST FLOOR

FHC

FH

C

FHC

FH

C

AREA LIGHT SHADED IS (E) NFPA 13 FIRE SPRINKLERED

75 FT RADIUS FOR FEC/FHC COVERAGE TYP

PROVIDE NEW NFPA 13 FIRE SPRINKLER PROTECTION FOR ALL NEW AND EXISTING SPACES IN THE BASEMENT THAT DO

NOT CURRENTLY HAVE FIRE SPRINKLERS (SEE DIAGRAM BELOW). CONNECT TO THE EXISTING FIRE PROTECTION

SERVICE MAINS AND PROVIDE NEW ZONE CONTROLS VALVES. AT EXISTING BASEMENT SPACES WITH 1974

APPROVED NFPA 13 FIRE SPRINKLER PROTECTION, UPGRADE ALL COMPONENTS TO CURRENT 2016 NFPA 13 FIRE

SPRINKLER PROTECTION.

NER

LEWA

A

T

AS

T

EOF L

R

N

FI O

I A

R

L

S

CI

ENAED

TET

HCI

C

91--5 31

C-15467

SHN

O

S.

J

EZ

UAR

C

HU

MB

OL

DT

ST

AT

E

UN

IVE

RS

ITY

Lib

ra

ry

-S

eis

mic

Re

no

va

tio

ns

Arc

ata,

Cal

ifo

rnia

Owner: Trustees of the California StateUniversity

Project Team

Project

Revisions

Sheet Name

Date

Owner #

SKA #

Sheet Number

Seals

Arch: Suarez-Kuehne ArchitectureSan Francisco, CA 94116

Struct: Thornton TomasettiSan Francisco, CA 94108

MEPT: Interface EngineeringSan Francisco, CA 94105

Acoust: Papadimos GroupSan Francisco, CA 94104

Civil: Stover EngineeringCrescent City, CA 95531

Land: Genevieve Schmidt - Landscape DesignMcKinleyville, CA 95521

Cost: Construction Cost Management ServicesOakland, CA 94612

A0.2

JUNE 8, 2018

EGRESSDIAGRAMS

1" = 20'-0"2

LEVEL BASEMENT - EGRESS PLAN PROPOSED

PROJECT NORTH

NORTH

1" = 20'-0"1

LEVEL BASEMENT - EGRESS PLAN EXISTING

PROJECT NORTH

NORTH

1 OWNER REV JUN 26, 2018

1

1

1

1

IFB #PW17-6, Addendum #1, Exhibit G, Page 1 of 4

Page 2: IFB #PW17-6, Addendum #1, Exhibit G, Page 1 of 4...APPROVED NFPA 13 FIRE SPRINKLER PROTECTION, UPGRADE ALL COMPONENTS TO CURRENT 2016 NFPA 13 FIRE SPRINKLER PROTECTION. N E R L EWA

44

55

77

88

9

10

11

A

A

B

B

C

C

D

D

E

E

F

F

H

H

I

I

J

J

K

K

L

L

M

M

33

22

66

LEVEL 1 ABOVE -SHOWN DASHED

A5.2

1

G

G

MECH ROOM

7CSTORAGE

6C

VETERANSADMINISTRATOR

OFFICE

7A

INTERN ASTUDENT OFFICE

7B

VETERANSENROLLMENT &

TRANSITIONSERVICES

7

SDRC OFFICES

8B

OFFICE

8A

STUDENTDISABILITYRESOURCE

CENTER

8

OFFICE

6B

SHAREDWORKSHOP

ROOM

55

INTERDEPARTMENTAL

56

OFFICE

4C

HSI-STEM

3

MECH

43B

A & CAC OFFICE

2

A & CAC OFFICE

1CONFERENCE

4D

F1

3.13.1

TESTING CENTERSERVICESOFFICES

21

TESTING 9STATIONS

22

TESTING 5STATIONS

23

TESTING /ASSESSMENTMONITORING

24

TESTING 4STATIONS

25

CUST

C-0A

ELEV MECH

28

TELECOM

29

TESTING 8STATIONS

30

TESTING 10STATIONS

32

TESTING 2STATIONS

34

FLEX OFFICE

35

FLEX OFFICE

38

FLEX OFFICE

39

A & CAC OFFICES

41

ELEV

EL-0A

A & CACSTORAGE OR

OFFICE

47

FLEX OFFICE

48

FLEX OFFICE

51

LIBRARYSTORAGE

61

MECH

62 LIBRARY OFFICESTORAGE

63

ELEV MACHINEROOM

64

ELEV PIT

LIBRARYSPECIAL

COLLECTIONS

61B

MECH

62B

MECH

62C

MECH

62D

WOMEN'S

RR-W-0

MECH

43A

CENTRAL STAIR

S-0A

PHOTOGRAPHYSTUDIO

61A

TESTINGPROCTOR

24A

OFFICE

21A

NW STAIR

S-0D

SW

ST

AIR

S-0

C

SE STAIR

S-0B

NE STAIR

S-0E

MECH

62A

LIBRARYSPECIAL

COLLECTIONS

61C

CUST

C-0B

UP

UP

UP

UP

UP

1

A3.1

(N) SHEAR WALL TYP(SSD)

(N) WDW WALL TYP

(N) SHEAR WALL TYP (SSD)

(N) SHEAR WALL TYP (SSD)

(N) 60MIN FIRE-RATEDEXT GLAZING TYP

(N) SHEAR WALL TYP(SSD)

(N) SHEAR WALL TYP(SSD)

(N) SHEARWALL TYP(SSD)

(N) SHEAR WALL TYP(SSD)

(N) FRP WRAP EXTCOLUMN TYP (SSD)

(N) FRP WRAP EXTCOLUMN (SSD)

(N) TS COL TYP (SSD)

(N) TS COL TYP (SSD)

(N) DOOR &HM FRAME

(N) DOOR & HMFRAME IN (N) OPNG

(N) DOOR & HMFRAME IN (N) OPNG

(E) SEISMICALLYBRACED STACKS

(N) PAVINGHATCHED(SCD)

(N) FRP WRAP EXTCOLUMN TYP (SSD)

(E) CURB

(N) PAVING(SCD)

(E) PAVING / CURB

(N) PAVINGHATCHED TYP(SCD)

(N) CONC INFILL @ (E)DOOR OPNG (SSD)

(N) CONC INFILL @ (E)DOOR OPNG (SSD)

(N) FRP WRAP@ (E) COL TYP(SSD)

(N) NON-RATED WALL@ (E) COL TYP

A6.6

1

A6.62

A6.63

A6.6

4

2

A3.1

FLEX OFFICE

52

SHAREDWORKROOM

KITCHENETTE

50

A & CAC OFFICE

58B

FLEX OFFICE

36

FLEX OFFICE

37

A & CAC OFFICE

59

A & CAC OFFICE

44

CONFERENCE

45

(N) DOOR @ (E) DOOROPNG (SSD)

A5.1

3

A5.1

4

OFFICE

40

A & CAC OFFICE

42

HALL

H-0B

HALL

H-0E

HALL

H-0C

43-A

5-A

5-B

6B-A

7C-A 7B-A

7A-A

S-0C-A

8B-A

8A-A

21A-A

50-A

51-A

H-0

C-A

LOBBY

5

S-0B-A

43B-A

HALL

H-0D

(N) WALL W/ ADDLACOUST GYP BD TYPBTWN OFFICES

(N)

FE

C

(E) FEC

(E) FEC

(E)

FE

C(E) FEC

A5.4

5

(N) 60MIN FIRE-RATEDOVERHEAD DOOR

NOTE (E) CONC COL HAS (E) CI RWL CAST IN COL (SSD) FOR REQD PROCEDURES

A9.4

2SIM

A9.3

5SIM

A5.5

8

HALL

H-0F

HALL

H-0G

CLST

4F

OFFICE

4B

OFFICE

4A

OFFICE

8C

OFFICE

8E

OFFICE

8D

COMMUNITYBASED

LEARNING

58

KITCHENETTE

58A

OFFICE

57

A & CAC OFFICE

3A

H-0A-A

4D-A

4C-A

4B-A

4A-A

H-0B-A H-0B-B

8C-A

8D-A

8E-A

58A-A

57-AH-0A-C

(E) 4" CONDUIT W/ (N) )OR RE-PULLED)TELECOM CABLE INADJACENT CONDUIT TOREMAIN - SEE DEMOPLAN (SED SSD)

ACADEMIC &CAREER

ADVISINGCENTER

4

H-0A-D

OFFICE

6A

6A-A

YOUTHEDUCATIONAL

SERVICES (YES)

6

(N) DOOR/FRAME IN (E) OPNG

(N) HI-LO DF

4-A

H-0A-B

STOR

4E4E-A

(N) PAVING HATCHEDTYP (SCD)

4-B

MECH

43

HALL

H-0A

MEN'S

RR-M-0

(N) CONC WALL TYP(SSD)

(N) FRP WRAP EXT COLUMN (SSD)

(N) FRP WRAP EXTCOLUMN (SSD)

(N) CONC WALL TYP(SSD)

(N) FRP WRAP EXTCOLUMN (SSD)

(N) CONC WALL TYP (SSD)

(N) CONC WALL TYP(SSD)

(N) FRP WRAP EXTCOLUMN TYP (SSD)

(N) DOOR & HMFRAME

(N) CONC WALL TYP(SSD)

(N) 60MIN FIRE-RATEDEXT GLAZING TYP

(N) 60MIN FIRE-RATEDEXT GLAZING TYP

(N) PAVING SHOWNHATCHED TYP (SCD)

(E) PAVING

3

1

2

5

L3

1

4

1 1

4

1

H-0F-A

8A7A

7

7

L1L2

L3

6

6 A5.2

5

1

A3.2

A7.3

3

A7.3

4

2

1

3A-A

A7.37

8

5

6

A7.3

10

12

11 9

A7.3

14

13

16

15

A7.43

4

1

2

A7.47

8

5

6

A7.4

10

911

12

81

REINSTALL (E) BLDG ALARM BELL (RECONNECT TO (E) LOCATION - SEE DEMO PLAN)

J6

J6

C4

E4 E4

D4

D4B4

D4

A4

F1

C4

G4

K4

K4

E4E4

E4

E4C4

D4

D4

E4

G4

G4

D4

D4

H4

H4

C4

C4

E4

D4

E4

D4

C4

E6

E6

E4

C4

G4

G4

D4

D4

D4

G4

G4

G4

D4

E4

E4

C4D4

D4

E4

G4

G4

D4

B4

A6.1

2

A6.2

1

A6.42

E4

G6

G6

B4

B4

6-A

A9.3

5SIM

A5.6

1

A5.6

2

A5.6

5

43-C

PROVIDE (N) THRES (C 6/A9.5) @ THESE (E) DOORS

PROVIDE (N) THRES (C 6/A9.5) @ THESE (E) DOORS

PROVIDE (N) FLOOR FINISH TRANSITION THRES (B 6/A9.5)

@ ALL (E) DOORS WITH (N) FLOOR FINISHES ON ONE OR BOTH SIDES OF DOOR OPNG

TYP UON

43-B

A5.6

8

A5.6

9

A5.6

10

5-I

A5.6

11

A5.6

5 OHSIM

G4

SEE BASEMENT DIMENSION PLANS A2.2.1 & A2.2.2 FOR INTERIOR PTN LOCATING

DIMENSIONS NOT SHOWN ON THIS PLAN

6C-A

3-A

A9.623

24

9

9

10

D4

(N) 30" HT TRANSACTIONCOUNTER W/ KNEESPACE BELOW

G4

NOTE ALL (E) CLEAN OUTS LOCATED IN NEW PAVING OR LANDSCAPE ARE TO HAVE THEIR ELEVS ADJUSTED TO MEET (N) PAVING & FIN

GRADES TYP (SCD)

CO

CO

(E) MANHOLE TOHAVE ELEVADJUSTED TOMEET (N) PAVING(SCD)

B3 B3A7.2

1415

A7.216

17 13

58B-A

(N) ONE-WAYGLASSWDW

A7.1

10

A7.1

11

(E) DRAININLET(SCD)

(E) IRRIGCONT (SID)

(E) IRRIG CONT (SID)

WATER QUICK CONNECT

(N) CONC WALL INFILL (SSD)

43B

-B

(N) SOLIDPOLYMERCTOP TYPTHIS ROOM

3'-8"

VIF

PROVIDE NEW NFPA 13 FIRE SPRINKLER PROTECTION FOR ALL NEW AND EXISTING SPACES IN THE BASEMENT THAT DO NOT CURRENTLY HAVE FIRE SPRINKLERS (SEE DIAGRAM SHEET A0.2). CONNECT TO THE

EXISTING FIRE PROTECTION SERVICE MAINS AND PROVIDE NEW ZONE CONTROLS VALVES. AT

EXISTING BASEMENT SPACES WITH 1974 APPROVED NFPA 13 FIRE SPRINKLER

PROTECTION, UPGRADE ALL COMPONENTS TO CURRENT 2016 NFPA 13 FIRE SPRINKLER

PROTECTION.

(E) WALL TO REMAIN SHOWN SOLID

WALL LEGEND - PROPOSED

(N) WALL SHOWN HATCHED GRAY(NON-RATED UON AS SHOWNBELOW WITH RATED DASHEDLINES)

(E) 1-HR FIRE RESISTANCE RATED INTWALL TYP

(E) 2-HR FIRE RESISTANCE RATED INTWALL TYP

(E) 1-HR FIRE RESISTANCE RATED INTCORRIDOR WALL TYP

1. FOR RCPs SEE A4.0 THROUGH 4.52. SEE WALL & PARTITION KEY/ DETAILS A11.1 THROUGH A11.53. PROVIDE ALL REQD BACKING PLATES FOR (N) EQUIP,

ACCESSORIES, CASEWORK, ETC PER BACKING PLATE SCHEDULEA11.1

4. SEE ROOM FINISH SCHEDULE A9.8 FOR DETAILS REQUIREMENTS5. SEE GLAZED OPENING SCHEDULE/ DETAILS A9.66. SEE DOOR SCHEDULE/ DETAILS A9.57. ALL DIMENSIONS NOTED ARE TO FACE OF FINISH, CENTER OF WALL

ASSEMBLY, OR GRID LINES UON8. FOR INTERIOR SIGNAGE LOCATION SEE SIGNAGE PLANS A2.2S,

DETAIL PLANS A5.49. SEE SITE PLAN A0.2 FOR SITE SIGNAGE LOCATIONS10. SEE EXTERIOR ELEVATIONS FOR EXTERIOR BUILDING SIGNAGE

A6.1 THROUGH A6.7

GENERAL PLAN NOTES

NER

LEWA

A

T

AS

T

EOF L

R

N

FI O

I A

R

L

S

CI

ENAED

TET

HCI

C

91--5 31

C-15467

SHN

O

S.

J

EZ

UAR

C

HU

MB

OL

DT

ST

AT

E

UN

IVE

RS

ITY

Lib

ra

ry

-S

eis

mic

Re

no

va

tio

ns

Arc

ata,

Cal

ifo

rnia

Owner: Trustees of the California StateUniversity

Project Team

Project

Revisions

Sheet Name

Date

Owner #

SKA #

Sheet Number

Seals

Arch: Suarez-Kuehne ArchitectureSan Francisco, CA 94116

Struct: Thornton TomasettiSan Francisco, CA 94108

MEPT: Interface EngineeringSan Francisco, CA 94105

Acoust: Papadimos GroupSan Francisco, CA 94104

Civil: Stover EngineeringCrescent City, CA 95531

Land: Genevieve Schmidt - Landscape DesignMcKinleyville, CA 95521

Cost: Construction Cost Management ServicesOakland, CA 94612

A2.2

JUNE 8, 2018

BASEMENTFLOORPROPOSEDPLAN

3/32" = 1'-0"1

LEVEL - BASEMENT - PROPOSED

PROJECT NORTH

NORTH

1 OWNER REV JUN 26, 2018

1

1

1

IFB #PW17-6, Addendum #1, Exhibit G, Page 2 of 4

Page 3: IFB #PW17-6, Addendum #1, Exhibit G, Page 1 of 4...APPROVED NFPA 13 FIRE SPRINKLER PROTECTION, UPGRADE ALL COMPONENTS TO CURRENT 2016 NFPA 13 FIRE SPRINKLER PROTECTION. N E R L EWA

Abbreviations

NUMBER#

AND&

ABANDON IN PLACE(A)

EXISTING(E)

FUTURE(F)

NEW(N)

RELOCATE / RELOCATED LOCATION(R)

DEMOLISH(X)

AT@

FOOT, FEET'

AQUASTAT, ARCHITECT, ANCHOR, AMPHEREA

ABOVE FINISHED FLOORAFF

ACCESS PANELAP

BELOW FINISHED FLOORBFF

BACKFLOW PREVENTERBFP

BUILDINGBLDG

BRITISH THERMAL UNITS PER HOURBTUH

CONDENSATE DRAINCD

CUBIC FEET PER HOURCFH

CUBIC FEET PER SECONDCFS

CLEANOUTCO

CONTINUATIONCONT.

CHECK VALVECV

COLD WATERCW

DRAIND

DOUBLE CHECK VALVE ASSEMBLYDCVA

DOMESTIC EXPANSION TANKDET

DRINKING FOUNTAINDF

DRAINAGE FIXTURE UNITDFU

DOWNDN

DOWNSPOUTDS

DOWNSPOUT NOZZLEDSN

DISHWASHER, DOMESTIC WATERDW

DRAINAGE, WASTE AND VENTDWV

ELECTRIC WATER COOLEREWC

ELECTRIC WATER HEATEREWH

FIRE, FAHRENHEITF

FLOOR CLEANOUTFCO

FLOOR DRAINFD

FINISHED FLOOR ELEVATIONFFE

FLOORFL

FEETFT

FLUSH VALVEFV

GALLONS PER MINUTEGPM

GAS WATER HEATERGWH

HOSE BIBBHB

HEATING, VENTILATING AND AIR CONDITIONINGHVAC

HOT WATERHW

HOT WATER FIXTURE UNITHWFU

HOT WATER RETURNHWR

HERTZHZ

INCHESIN, "

INVERT ELEVATIONINV

INDIRECT WASTEIW

LAVATORYL

MINIMUMMIN

MOP SINKMS

MIXING VALVEMX

NORTHN

NOT IN CONTRACTNIC

NUMBERNO.

NOT TO SCALENTS

OVERFLOW DRAIN, OUTSIDE DIAMETEROD

OWNER FURNISHED, CONTRACTOR INSTALLEDOFCI

OWNER FURNISHED, OWNER INSTALLEDOFOI

PLUMBING, PUMPP

PRESSURE DROP, PLUMBING DEMOLITION, PUMPED DISCHARGEPD

PLUMBINGPLBG

POINT OF CONNECTIONPOC

PRESSURE REDUCING VALVEPRV

POUNDS PER SQUARE INCHPSI

QUANTITYQTY

ROOF DRAINRD

REDUCED PRESSURE BACKFLOW PREVENTERRPBP

RAINWATER LEADERRWL

SINKS, SK

SHOCK ARRESTORSA

SANITARYSAN

SERVICE BOXSB

STORM DRAINSD

SQUARE FEETSF

SHEETSHT

SHUT OFF VALVESOV

SUMP PUMP, STATIC PRESSURESP

TEMPERATURETEMP

TRAP PRIMER, TOTAL PRESSURETP

TYPICALTYP

URINALU, UR

VACUUM, VENT, VOLTV

VENT THRU ROOFVTR

WITHW/

WASTEW

WATER COLUMN, WATER CLOSETWC

WALL CLEANOUTWCO

WATER HEATER, WALL HYDRANTWH

WATER HAMMER ARRESTORWHA

WATER SUPPLY FIXTURE UNITWSFU

General

DEMOLISH

EXISTING WORK

NEW WORK

PIPE OR CONDUIT BELOW GRADE

CONTINUATION

EQUIPMENT IDENTIFICATION

XX-X

LOCATION

EXTENT OF DEMOLITION

FIXTURE TAG (LEVEL BELOW FIXTURE)

X

KEYED NOTE

X

POINT OF CONNECTION

Piping Fittings

ACCESS PANEL

AP

AQUASTAT

BLIND FLANGE

CAP

CLEANOUT TO GRADE

COTG

CONCENTRIC REDUCER

DOWNSPOUT NOZZLE

DSN

ECCENTRIC REDUCER

FLOOR CLEANOUT

FCO

FLOOR DRAIN

FD

FLOOR SINK

FS

FLOW DIRECTION

HOSE BIBB / WALL HYDRANT

OVERFLOW ROOF DRAIN

OD

PIPE DROP

PIPE RISE

PUMP

ROOF DRAIN

RD

SHOCK ABSORBER / WATER HAMMER ARRESTOR

S

STRAINER

T&P RELIEF VALVE WITH PIPE TO DRAIN

TEE DOWN ON PIPE

TEE UP ON PIPE

VENT THROUGH ROOF

VTR

WALL CLEANOUT

WCO

Piping Systems

COLD WATER PIPING

CONDENSATE / INDIRECT DRAIN PIPING

D

HOT WATER PIPING

HOT WATER RETURN PIPING

NATURAL GAS PIPING, 2 LB

2#G

NATURAL GAS PIPING, 7" WC PRESSURE

G

OVERFLOW DRAIN PIPING ABOVE GRADE OR FINISHED FLOOR

OD

SANITARY VENT PIPING

SANITARY WASTE OR SOIL PIPING ABOVE GRADE OR FINISHED FLOOR

SANITARY WASTE OR SOIL PIPING BELOW GRADE OR FINISHED FLOOR

STORM DRAIN PIPING ABOVE GRADE OR FINISHED FLOOR

SD

STORM DRAIN PIPING BELOW GRADE OR FINISHED FLOOR

SD

TRAP PRIMER PIPING

TP

Valves

BACKFLOW PREVENTER

BFP

CHECK VALVE

SHUTOFF VALVE, GENERAL

PLUMBING SYMBOL LIST

NOTE: This is a standard symbol list and not all items listed may be used.

SHEET INDEX

P0.1 SYMBOL LIST AND GENERAL NOTES - PLUMBING

P0.2 SCHEDULES - PLUMBING

PD2.0 BASEMENT DEMOLITION PLAN - PLUMBING

PD2.2 LEVEL 2 DEMOLITION PLAN - PLUMBING

P2.0 BASEMENT PLAN - PLUMBING

P2.2 LEVEL 2 PLAN - PLUMBING

P3.0 ENLARGED PLANS - PLUMBING

GENERAL PLUMBING NOTES

A. CONDITIONS SHOWN ON THE PLANS RELATIVE TO THE WORK TO BE

PERFORMED ARE BASED ON THE BEST INFORMATION AVAILABLE AND

SUBJECT TO VERIFICATION. VERIFY LOCATIONS AND ELEVATIONS OF

UTILITIES TO BE CROSSED OR CONNECTED. CORRECT DEFICIENCIES

CAUSED BY FAILURE TO PERFORM SUCH VERIFICATIONS AT NO

EXPENSE TO OWNER. IMMEDIATELY NOTIFY ARCHITECT AND ENGINEER

OF CONDITION IN CONFLICT WITH DETAILS/PLANS.

B. COORDINATE INSTALLATION OF PIPING, FIXTURES, EQUIPMENT AND THE

LIKE BELOW AND ABOVE GRADE WITH STRUCTURAL COMPONENTS AND

OTHER SYSTEMS INSTALLATION.

C. COORDINATE FIXTURES, EQUIPMENT, PIPE ROUGH-IN/CONNECTION

LOCATIONS AND DRAIN LOCATIONS WITH ARCHITECTURAL DRAWINGS.

D. LOCATE VALVES FOR SERVICE ACCESSIBILITY. VALVES INSTALLED

ABOVE CEILING SHALL BE WITHIN 18" OF CEILING.

E. SEE PLUMBING FIXTURE SCHEDULE FOR PIPE CONNECTION SIZES.

F. PROVIDE NEW CW, HW, W/SOV FROM (E) MAIN TO ALL PLUMBING

FIXTURE(S)

GENERAL FIRE PROTECTION NOTES

A. PROVIDE NEW SPRINKLER PROTECTION IN ACCORDANCE WITH NFPA 13

FOR ALL NEW AND EXISTING SPACES IN THE BASEMENT THAT DO NOT

CURRENTLY HAVE FIRE SPRINKLERS (SEE ARCHITECTURAL DRAWINGS) .

CONNECT TO THE EXISTING FIRE PROTECTION SERVICE MAINS AND

PROVIDE NEW ZONE CONTROL VALVES. AT EXISTING BASEMENT SPACES

WITH 1974 APPROVED NFPA 13 FIRE SPRINKLER PROTECTION, UPGRADE

ALL COMPONENTS TO CURRENT 2016 NFPA 13 REQUIREMENTS.

Lib

ra

ry

- S

eis

mic

Re

no

va

tio

ns

S K

a

rc

hit

ec

tu

re

ua

re

z u

eh

ne

2412 1

4th

Aven

ue

Cal

iforn

ia , 94116

tel

4

15.2

42.1

400

Sa

nF

oi

cn

ar

cs

REV 01 JUN 26, 2018

IFB #PW17-6, Addendum #1, Exhibit G, Page 3 of 4

gmm18
Polygon
Page 4: IFB #PW17-6, Addendum #1, Exhibit G, Page 1 of 4...APPROVED NFPA 13 FIRE SPRINKLER PROTECTION, UPGRADE ALL COMPONENTS TO CURRENT 2016 NFPA 13 FIRE SPRINKLER PROTECTION. N E R L EWA

44

55

77

88

9

10

11

A

A

B

B

C

C

D

D

E

E

F

F

H

H

I

I

J

J

K

K

L

L

M

M

33

22

66

G

G

MECH ROOM

7C

STORAGE

6C

VETERANS

ADMINISTRATOR

OFFICE

7A

INTERN A

STUDENT OFFICE

7B

VETERANS

ENROLLMENT &

TRANSITION

SERVICES

7

SDRC OFFICES

8B

OFFICE

8A

STUDENT

DISABILITY

RESOURCE

CENTER

8

OFFICE

6B

SHARED

WORKSHOP

ROOM

55

INTERDEPARTMENTAL

56

OFFICE

4C

HSI-STEM

3

MECH

43B

A & CAC OFFICE

2

A & CAC OFFICE

1

CONFERENCE

4D

F1

3.13.1

TESTING CENTER

SERVICES

OFFICES

21

TESTING 9

STATIONS

22

TESTING 5

STATIONS

23

TESTING /

ASSESSMENT

MONITORING

24

TESTING 4

STATIONS

25

CUST

C-0A

ELEV MECH

28

TELECOM

29

TESTING 8

STATIONS

30

TESTING 10

STATIONS

32

TESTING 2

STATIONS

34

FLEX OFFICE

35

FLEX OFFICE

38

FLEX OFFICE

39

A & CAC OFFICES

41

ELEV

EL-0A

A & CAC

STORAGE OR

OFFICE

47

FLEX OFFICE

48

FLEX OFFICE

51

LIBRARY

STORAGE

61

MECH

62

LIBRARY OFFICE

STORAGE

63

ELEV MACHINE

ROOM

64

ELEV PIT

LIBRARY

SPECIAL

COLLECTIONS

61B

MECH

62B

MECH

62C

MECH

62D

WOMEN'S

RR-W-0

MECH

43A

CENTRAL STAIR

S-0A

PHOTOGRAPHY

STUDIO

61A

TESTING

PROCTOR

24A

OFFICE

21A

NW STAIR

S-0D

SW

S

TA

IR

S-0C

SE STAIR

S-0B

NE STAIR

S-0E

MECH

62A

LIBRARY

SPECIAL

COLLECTIONS

61C

CUST

C-0B

FLEX OFFICE

52

SHARED

WORKROOM

KITCHENETTE

50

A & CAC OFFICE

58B

FLEX OFFICE

36

FLEX OFFICE

37

A & CAC OFFICE

59

A & CAC OFFICE

44

CONFERENCE

45

OFFICE

40

A & CAC OFFICE

42

HALL

H-0B

HALL

H-0E

HALL

H-0C

LOBBY

5

HALL

H-0D

HALL

H-0F

HALL

H-0G

CLST

4F

OFFICE

4B

OFFICE

4A

OFFICE

8C

OFFICE

8E

OFFICE

8D

COMMUNITY

BASED

LEARNING

58

KITCHENETTE

58A

OFFICE

57

A & CAC OFFICE

3A

ACADEMIC &

CAREER

ADVISING

CENTER

4

OFFICE

6A

YOUTH

EDUCATIONAL

SERVICES (YES)

6

STOR

4E

MECH

43

HALL

H-0A

MEN'S

RR-M-0

3

1

2

5

L3

1

4

1 1

4

1

7

7

L1

L2

L3

6

6

8

1

9

9

10

SHEET KEYNOTES

1 (BASE BID) CONNECT NEW NATURAL GAS PIPE TRAIN TO NEW

4000 MBH BOILER.

2 (ALTERNATE ONLY) CONNECT NEW NATURAL GAS PIPE TRAIN

TO NEW 3500 MBH BOILER.

3 REROUTE NEW 6" PIPE GAS PIPE AROUND SHEAR WALL.

4 REROUTE SPRINKLER LINES AROUND NEW WORK AT

COLUMN. SEE ARCHITECTURAL DRAWING A5.1 DETAIL 2.

5 ROUTE NEW 1" CONDENSATE FROM BOILER TO FD.

6 UP TO NEW DF.

7 INSTALL NEW SINK, FAUCET, TRIM, P-TRAP, AND SERVICE

STOPS TO EXISTING ROUGH-INS.

2

TO EXISTING

BOILER

MECH ROOM

7C

STORAGE

6C

VETERANS

ADMINISTRATOR

OFFICE

7A

INTERN A

STUDENT

OFFICE

7B

VETERANS

ENROLLMENT

&

TRANSITION

SERVICES

7

SDRC

OFFICES

8B

OFFICE

8A

STUDENT

DISABILITY

RESOURCE

CENTER

8

OFFICE

6B

SHARED

WORKSHOP

ROOM

55

INTERDEPARTMENTAL

56

OFFICE

4C

HSI-STEM

3

MECH

43B

A & CAC

OFFICE

2

A & CAC

OFFICE

1

CONFERENCE

4D

TESTING

CENTER

SERVICES

OFFICES

21

TESTING

9 STATIONS

22

TESTING

5 STATIONS

23

TESTING /

ASSESSMENT

MONITORING

24

TESTING

4 STATIONS

25

CUST

C-1A

ELEV MECH

28

TELECOM

29

TESTING

8 STATIONS

30

TESTING

10 STATIONS

32

TESTING

2 STATIONS

34

FLEX OFFICE

35

FLEX OFFICE

38

FLEX OFFICE

39

A & CAC

OFFICES

41

ELEV

EL-0A

A & CAC

STORAGE OR

OFFICE

47

FLEX OFFICE

48

FLEX OFFICE

51

LIBRARY

STORAGE

61

MECH

62

LIBRARY

OFFICE

STORAGE

63

ELEV

MACHINE

ROOM

64

ELEV PIT

LIBRARY

SPECIAL

COLLECTIONS

61B

MECH

62B

MECH

62C

MECH

62D

MEN'S

WOMEN'S

RR-W-0

MECH

43A

CENTRAL

STAIR

S-0A

PHOTOGRAPHY

STUDIO

61A

TESTING

PROCTOR

24A

OFFICE

21A

NW STAIR

S-0D

SW STAIR

S-0C

SE STAIR

S-0B

NE STAIR

S-0E

MECH

62A

LIBRARY

SPECIAL

COLLECTIONS

61C

CUSTODIAL

C-0B

FLEX OFFICE

53

FLEX OFFICE

52

SHARED

WORKROOM

KITCHENETTE

50

A & CAC

OFFICE

58B

FLEX OFFICE

36

FLEX OFFICE

37

A & CAC

OFFICE

59

A & CAC

OFFICE

44

CONFERENCE

45

OFFICE

40

A & CAC

OFFICE

42

HALL

H-0B

HALL

H-0E

HALL

H-0C

LOBBY

5

HALL

H-0D

HALL

H-0A

HALL

H-0F

HALL

H-0G

CLST

4E

OFFICE

4B

OFFICE

4A

OFFICE

8C

OFFICE

8E

OFFICE

8D

COMMUNITY

BASED

LEARNING

58

KITCHENETTE

58A

OFFICE

57

A & CAC

OFFICE

3A

ACADEMIC &

CAREER

ADVISING

CENTER

4

OFFICE

6A

YOUTH

EDUCATIONAL

SERVICES

(YES)

6

STOR

4E

MECH

43

4

P3.0

G

G G

5" EXISTING GAS

EX 4"

B-1

1

2

3

FS

45"EX 4"

NEW BOILER

B-2

EX 3/4"

5

5

GENERAL NOTES

1 THE TOILET ROOM WORK INCLUDES FIXTURE REPLACEMENT

WITH SLIGHT RELOCATION. ADJUST PIPING SYSTEMS AND

HANGERS AND RELOCATE ROUGH-INS. PROVIDE NEW

SERVICE STOPS, CARRIERS, P-TRAPS, AND TRAP ARMS.

SANITARY CALCULATIONS

FIXTURES ADDED:

WC (4 DFU) X 5 = 20 DFU

LAV (1 DFU) X 6 = 6 DFU

UR (2 DFU) X 2 = 4 DFU

TOTAL = 31 DFU

FIXTURES REMOVED:

WC (4 DFU) X 5 = 20 DFU

LAV (1 DFU) X 6 = 6 DFU

UR (2 DFU) X 2 = 4 DFU

TOTAL = 30 DFU

0.5 DFU ADDED TO BASEMENT NEW WORK

DF (.5DFU) X 2 = 1 DFU DF (.5DFU) X 1 = .5 DFU

WATER CALCULATIONS

FIXTURES ADDED:

WC (5 SFU) X 5 = 25 SFU

LAV (1 SFU) X 6 = 6 SFU

UR (4 SFU) X 2 = 8 SFU

TOTAL = 40 SFU

FIXTURES REMOVED:

0.5 SFU ADDED TO BASEMENT NEW WORK. PEAK DOMESTIC

DF (.5 SFU) X 2 = 1 SFU

WC (5 SFU) X 5 = 25 SFU

LAV (1 SFU) X 6 = 6 SFU

UR (4 SFU) X 2 = 6 SFU

TOTAL = 39.5 SFU

DF (.5 SFU) X 1 = .5 SFU

WATER DEMAND IS UNCHANGED.

1-1/2"

ABV CLG

6

6

P3.0

1

P0.2

7

EX 3/4 HW

EX 3/4 HWR

EX 3/4 CW

3/4" HW

EX1/2" CW

3/4" HWR

7

SK-1

SK-1

2. PROVIDE NEW SPRINKLER PROTECTION IN ACCORDANCE WITH NFPA 13

FOR ALL NEW AND EXISTING SPACES IN THE BASEMENT THAT DO NOT

CURRENTLY HAVE FIRE SPRINKLERS (SEE ARCHITECTURAL DRAWINGS) .

CONNECT TO THE EXISTING FIRE PROTECTION SERVICE MAINS AND

PROVIDE NEW ZONE CONTROL VALVES. AT EXISTING BASEMENT SPACES

WITH 1974 APPROVED NFPA 13 FIRE SPRINKLER PROTECTION, UPGRADE

ALL COMPONENTS TO CURRENT 2016 NFPA 13 REQUIREMENTS.

0 16' 24'

SCALE: 3/32"=1'-0"

8'

1 BASEMENT PLAN - PLUMBING

Lib

ra

ry

- S

eis

mic

Re

no

va

tio

ns

S K

a

rc

hit

ec

tu

re

ua

re

z u

eh

ne

2412 1

4th

Aven

ue

Cal

iforn

ia , 94116

tel

4

15.2

42.1

400

Sa

nF

oi

cn

ar

cs

REV 01 JUN 26, 2018

IFB #PW17-6, Addendum #1, Exhibit G, Page 4 of 4

gmm18
Polygon