If you lack the skills, tools or equipment to perform ... · rcp-b (det ca) a/c zone #1 gfi-1 can...
Transcript of If you lack the skills, tools or equipment to perform ... · rcp-b (det ca) a/c zone #1 gfi-1 can...
![Page 1: If you lack the skills, tools or equipment to perform ... · rcp-b (det ca) a/c zone #1 gfi-1 can (blu) bath pur-2 from load center to galley slideout rcp-2 (blu) 110v connections](https://reader030.fdocuments.net/reader030/viewer/2022011809/5d28ccd888c99392328c8068/html5/thumbnails/1.jpg)
Danger of electrical shock, burns or death. Always remove all power sources before attempting any repair, service or diagnostic work. Power can be present from shore power, generator, inverter or battery. All power sources must
be disabled and secured before performing any service.
If you lack the skills, tools or equipment to perform diagnostic or repair work leave such work to an authorized
Winnebago Industries dealer or other qualified shop.
Copyright © 2014 Winnebago Industries, Inc.
![Page 2: If you lack the skills, tools or equipment to perform ... · rcp-b (det ca) a/c zone #1 gfi-1 can (blu) bath pur-2 from load center to galley slideout rcp-2 (blu) 110v connections](https://reader030.fdocuments.net/reader030/viewer/2022011809/5d28ccd888c99392328c8068/html5/thumbnails/2.jpg)
1.5
265
ALL GROUND WIRE TO BE COVERED WITH TUBING 8041-02-000.
SEE LOAD CENTER/ATS ASM FOR ADDITIONAL INFORMATION.
DRAWING NO.
78J
6
1B1
5
EA
X-X
FORELECTRICAL
CALLOUTSSEE DWG NO.
121339-01-000
ELECTRICAL SYSTEM-50 AMP
1.
MOUNT ATS AS HIGH AS POSSIBLE IN COMPARTMENT.ROUTE GROUND CABLE WITH GENERATOR WIRES THROUGHPANEL & CONNECT TO FRAME RAIL GROUND.
NOTES:
FEATURE
ALL 110V WIRE TO BE CLAMPED WITH CLAMP 10497-05-000WITHIN 200MM OF OUTLET BOXES, USE SCREW G67-10-12B.
1 7
CODES/STANDARDS USA
WIRE PASSES THROUGH FLOOR AT THIS POINT.
2.
A
78J
3.
5
6
14 J37F
RELEASE
186520-12
6
186520
1B1(WHT)TO WATER HEATERFROM LOAD CENTER
FOR ELECTRICALTORQUE
SPECIFICATIONSSEE DWG NO.
128783-01-000
186520-01
78J
CODES/STANDARDS-CSA/CMVSS
1B1
ATS
2
C
CHKR
PART NO
DSNR
REV
3
P.E.
6
REVISION RECORD
57
D
ALL DIMENSIONS ARE IN MILLIMETERS
A
ANGLE
ORIG. DATE
FIRST USED
D
MATERIAL:
COPYRIGHT 2014WINNEBAGO
INDUSTRIES, INC.
B
4
ZONE
WHOLE DIM (X)
C
REV DWGNO
DATE
THIRD ANGLE
4
DFTR-ORIG
ONE-PLACE (X.X)
DO NOT SCALE DRAWING
26
TWO-PLACE (X.XX)
A
R
8
1
DFTR
5
PROJECTION
DATE
TITLE:
8 REF:
UNSPECIFIED TOLERANCES ARE:
3
REFER TO ES0018 FOR FASTENERTIGHTENING GUIDELINES
M.E.
7
B
1
REV
OFSHEET
78J
0.50
1000 DROPTO LOAD CENTERBLK,BRN,YEL,PUR,GLD-2,GLD,MAINTO LOAD CENTER
265
1
ALL WIRES TO BE SECURED WITH CLAMP 10495-01-000OR CLIP 80734-01-000 EVERY 600MM. USE SCREWG67-10-12B UNLESS OTHERWISE SPECIFIED.
--------
WATER HEATERJUNCTION BOXCONNECTOR58028-01-000 (2)
186520-16
265
4. SEE WIRING DIAGRAM-BODY,110V FOR ADDITIONAL INFORMATION.
186520WIRING INSTL-BODY,110V
3
7
300 DROP10 GA INVERTER INPUT AND10 GA INVERTER OUPUT CIRCUITSORG ROMEX
300 DROPPUR,YEL,BRN,BLK,GLD-2 & GLDTO GALLEY 110VCONNECTIONSUNDER FLOORDETAIL FA
(BLU) 300 LOOPTO EXT RCP
RCP-2 (BLU)EXT RCP
BRACKET155223-12-CHTSCREWG67-10-08U (3)(MOUNT TO RISERAT DIM SHOWN)
7
GROMMET23942-01-000 (3)
GROMMET23942-01-000
(BLU) 110V CONNECTORMOUNTED HEREDETAIL FB
COVER-WIRE170196-02-CHTSCREWG39-08-12U (2)
LARGE LOOP (BLU)FROM LOAD CENTERTHRU BATH GFI& REAR BATHTO RCP-2 EXT RCP& RT FRT SLIDE110V CONNECTIONSWHT DROPTO LOAD CENTER
AA
MAINTO LOAD CENTER
POWER CORD
GENERATORPOWER CABLE
VIEW AA
CLAMP10497-03-000 (2)SCREWG39-08-12U (2)
PANEL-RECEPTACLE151376-01-CHTSCREWG11-08-12U (4)
45
195COVER-WIRE170196-05-CHTSCREWG39-08-12U (6)
CABLE-GENERATOR,POWER(SUPPLIED W/GENERATOR)ROUTE TO ATS AND REDUCELENGTH FOR PROPER FIT
*1
86
52
0 *
03-Jun-2014
![Page 3: If you lack the skills, tools or equipment to perform ... · rcp-b (det ca) a/c zone #1 gfi-1 can (blu) bath pur-2 from load center to galley slideout rcp-2 (blu) 110v connections](https://reader030.fdocuments.net/reader030/viewer/2022011809/5d28ccd888c99392328c8068/html5/thumbnails/3.jpg)
265
WIRING INSTL-BODY,110V
5
RCP-2 (PUR-2)A/V PREP
SEE WIRING DIAGRAM-BODY,110V FOR ADDITIONAL INFORMATION.
2.
1B1 78J
4.
ALL WIRES TO BE SECURED WITH CLAMP 10495-01-000OR CLIP 80734-01-000 EVERY 600MM. USE SCREWG67-10-12B UNLESS OTHERWISE SPECIFIED.
2
GFI-1 CAN (BRN)GALLEY
1B1
ELECTRICAL SYSTEM-50 AMP
1.
CODES/STANDARDS USA
186520
78J
RCP-1 (BLK)MICROWAVE
GALLEY SLIDEOUT110V CONNECTIONSBRACKET155223-12-CHTSCREWG67-10-08U (3)(MOUNT TO SLIDEOUT FLOORCENTERED IN CABINETTOUCHING CABINET FACE)DETAIL FA
ROUTE 110V WIRESWITH WATER LINES
NOTES:
FOR ELECTRICALTORQUE
SPECIFICATIONSSEE DWG NO.
128783-01-000
X-X
FORELECTRICAL
CALLOUTSSEE DWG NO.
121339-01-000
D
C
1
FIRST USED
8 3
B
28 1
DO NOT SCALE DRAWING
4
4DWGNO
3
TITLE:
C
6
B
7 5
PART NO
2
D
REV
5
AA
6
7
SHEET
WIRE ROUTED THROUGH FLOOR AT THIS POINT.
ALL GROUND WIRE TO BE COVERED WITH TUBING 8041-02-000.3.
CODES/STANDARDS-CSA/CMVSS
5
ALL 110V WIRE TO BE CLAMPED WITH CLAMP 10497-05-000WITHIN 200MM OF OUTLET BOXES, USE SCREW G67-10-12B. 14 J37F
186520
265
GFI-1 US (BRN)GALLEY
RCP-3 (YEL-2)REFRIGERATOR
RCP-2 (BRN)SIDEWALL SP-04
RCP-3 (GLD)WASHER
SP-04
RCP-2 (BLU)REAR BATH
(BLK) FROM SIDEWALLTO 110V CONNECTORDETAIL FA
EC
RCP-2 (BRN)SIDEWALL SP-04
RCP-TV (PUR)SEE WIRING INSTL-TV/DVDFOR ADDITIONAL INFORMATION
RCP-3 (GLD-2)DRYER
SP-04
RCP-2 (PUR-2)BEDROOM TV
*1
86
52
0 *
RCP-2 (BRN)GALLEY
03-Jun-2014
![Page 4: If you lack the skills, tools or equipment to perform ... · rcp-b (det ca) a/c zone #1 gfi-1 can (blu) bath pur-2 from load center to galley slideout rcp-2 (blu) 110v connections](https://reader030.fdocuments.net/reader030/viewer/2022011809/5d28ccd888c99392328c8068/html5/thumbnails/4.jpg)
GFI-1 US (BLU)BATH
RCP-2 (PUR)BED REAR
DA
2.
ALL GROUND WIRE TO BE COVERED WITH TUBING 8041-02-000.
3
DETAIL CC
78J
110VCONNECTION(PUR)DETAIL DA
ALL WIRES TO BE SECURED WITH CLAMP 10495-01-000OR CLIP 80734-01-000 EVERY 600MM. USE SCREWG67-10-12B UNLESS OTHERWISE SPECIFIED.
CODES/STANDARDS-CSA/CMVSS
SP-04
RCP-1 BED(PUR)
SEE EXTERIOR ENT CTR FOR ADDITIONAL INFORMATION.
7
RCP-2 (PUR)FRONT SDW
RCP-B (DET CA)A/C ZONE #1
GFI-1 CAN (BLU)BATH
PUR-2
FROM LOADCENTER
TO GALLEY SLIDEOUT110V CONNECTIONSRCP-2 (BLU)
LOUNGE
X-X
FORELECTRICAL
CALLOUTSSEE DWG NO.
121339-01-000
FOR ELECTRICALTORQUE
SPECIFICATIONSSEE DWG NO.
128783-01-000
D
C
1
FIRST USED
8 3
B
28 1
DO NOT SCALE DRAWING
4
4DWGNO
3
TITLE:
C
6
B
7 5
PART NO
2
D
REV
5
AA
6
7
SHEET
4.
ALL 110V WIRE TO BE CLAMPED WITH CLAMP 10497-05-000WITHIN 200MM OF OUTLET BOXES, USE SCREW G67-10-12B.
PUR-2
6
WIRE IN ROOF.
265
SP-04
78J
WIRE ROUTED THROUGH FLOOR AT THIS POINT.
CODES/STANDARDS USA
1.
NOTES:
LOAD CENTER/ATS ASM184319-02-000
7
186520
186520
110V CONNECTION(PUR)DETAIL DA
265
7
6
7
SEE WIRING DIAGRAM-BODY,110V FOR ADDITIONAL INFORMATION.
TO RCP-B TV'S
8
7
3.
1B1
5
WIRING INSTL-BODY,110V
14 J37F
WIRE IN SIDEWALL.
ELECTRICAL SYSTEM-50 AMP
1B1
RCP-2 (PUR)BED FRONT
(PUR)RCP-EXT TV
8
COVER-WIRE153862-02-CHTSCREWG67-10-12B (4)
1DF
1DF EXT TV ENTERTAINMENT CENTER
RCP-B (DET CD)TV'S
RCP-B (DET CA)A/C ZONE #2
5
FROM LOADCENTER
TO FRONTA/C ZONE#1
DETAIL CB
RCP-B AC ZONE #2(GRN)
DETAIL CA
RCP-B AC ZONE #1(RED)
FROM LOADCENTER
TO REARA/C ZONE #2
SP-04 7
TO 110V CONNECTIONUNDER BED
SEE DETAIL DA
THROW IN #2
PUR-2
RCP-1 (PUR)BED
*1
86
52
0 *
THROW IN #2
DETAIL CD
RCP-B TV'S(PUR)
FROM RCP-1 BED(DET CC) TO RCP-B FRONT
8
03-Jun-2014
![Page 5: If you lack the skills, tools or equipment to perform ... · rcp-b (det ca) a/c zone #1 gfi-1 can (blu) bath pur-2 from load center to galley slideout rcp-2 (blu) 110v connections](https://reader030.fdocuments.net/reader030/viewer/2022011809/5d28ccd888c99392328c8068/html5/thumbnails/5.jpg)
CODES/STANDARDS-CSA/CMVSS265
265
ELECTRICAL SYSTEM-50 AMP
CODES/STANDARDS USA
186520
78J
X-X
FORELECTRICAL
CALLOUTSSEE DWG NO.
121339-01-000
D
C
1
FIRST USED
8 3
B
28 1
DO NOT SCALE DRAWING
4
4DWGNO
3
TITLE:
C
6
B
7 5
PART NO
2
D
REV
5
AA
6
7
SHEET
14 J37F1B1
1B1
186520
4
FOR ELECTRICALTORQUE
SPECIFICATIONSSEE DWG NO.
128783-01-000 WIRING INSTL-BODY,110V
78J
3
CLAMP10495-01-000 (4)SCREWG67-10-12B (4)
USE CONNECTOR-WIRE,NM144283-02-000TO CONNECT TOWIRE FROM SIDEWALL
WIRE FROMSIDEWALL
SLIDEOUT #2WIRE #14
DETAIL DA
CLAMP10497-03-000 (3)SCREWG39-06-12B (3)
SCREWG39-06-24B (8)
110V PUR-2THROW IN #2 FROMRCP-B TV'S TO RCP-1 BEDSEE DETAIL CC & CD
NOTES:
WIRE MUST BE ROUTED THROUGH CLAMPS AS SHOWN.
MAKE LOOP AS SMALL AS POSSIBLE WHEN SLIDEOUT IS COMPLETELY RETRACTED.
1.
3
4 SEE LOAD CENTER/ATS ASM FOR ADDITIONAL INFORMATION.
RUN 12V WIRE ALONG WITH REAR SLIDEOUT WIRE.2.
RCP-1 AIR BED(REF)SEE DET CC
*1
86
52
0 *
03-Jun-2014
![Page 6: If you lack the skills, tools or equipment to perform ... · rcp-b (det ca) a/c zone #1 gfi-1 can (blu) bath pur-2 from load center to galley slideout rcp-2 (blu) 110v connections](https://reader030.fdocuments.net/reader030/viewer/2022011809/5d28ccd888c99392328c8068/html5/thumbnails/6.jpg)
X-X
FORELECTRICAL
CALLOUTSSEE DWG NO.
121339-01-000
FOR ELECTRICALTORQUE
SPECIFICATIONSSEE DWG NO.
128783-01-000
D
C
1
FIRST USED
8 3
B
28 1
DO NOT SCALE DRAWING
4
4DWGNO
3
TITLE:
C
6
B
7 5
PART NO
2
D
REV
5
AA
6
7
SHEET
1B1
186520
CODES/STANDARDS-CSA/CMVSS
ELECTRICAL SYSTEM-50 AMP
14 J37F
265
5
WIRING INSTL-BODY,110V
401
186520
1B1
78J265
INVERTER-DC/AC, 1000 WATT
CODES/STANDARDS USA
VIEW EA
VIEW EB
40A INVERTER-DC/AC WITHOUT
NOTES:
SEE LOAD CENTER/ATS ASM FOR ADDITIONAL INFORMATION.1
1
1
AC OUTPUT10 GA WIREFROM INVERTERBREAKER PANELDETAIL EB
BRACKET ASM-MOUNT,INVERTER176315-10-CHTRIVET113133-01-CHT (4)
INVERTER175386-02-000NUTD39-06-00B (4)
CONNECTOR-WIRE008311-01-000 (5)
AC INPUT10 GA WIREFROM MAINBREAKER PANELDETAIL EB
WIRE ASM-GROUND
POSITIVE BATTERYCABLE CONNECTION
NEGATIVE BATTERYCABLE CONNECTION
1
REMOTE DISPLAYPANEL & AC TEMPSENSOR CONNECTION
*1
86
52
0 *
78J
03-Jun-2014
![Page 7: If you lack the skills, tools or equipment to perform ... · rcp-b (det ca) a/c zone #1 gfi-1 can (blu) bath pur-2 from load center to galley slideout rcp-2 (blu) 110v connections](https://reader030.fdocuments.net/reader030/viewer/2022011809/5d28ccd888c99392328c8068/html5/thumbnails/7.jpg)
D
C
1
FIRST USED
8 3
B
28 1
DO NOT SCALE DRAWING
4
4DWGNO
3
TITLE:
C
6
B
7 5
PART NO
2
D
REV
5
AA
6
7
SHEET
14 J37F
WIRING INSTL-BODY,110V
186520
1865206
X-X
FORELECTRICAL
CALLOUTSSEE DWG NO.
121339-01-000
FOR ELECTRICALTORQUE
SPECIFICATIONSSEE DWG NO.
128783-01-000
ELECTRICAL SYSTEM-50 AMP
265 78J
1B1
265 CODES/STANDARDS-CSA/CMVSS
CODES/STANDARDS USA
78J
1B1
CLAMP10495-01-000 (22)SCREWG39-08-08U (22)
SCREWG39-06-16B (36)
LOCATED UNDERMAIN FLOOR(SEE SHT 1
FOR LOCATION)
LOCATED UNDERGALLEY DRAWERS
(SEE SHT 2FOR LOCATION)
CONNECTOR-WIRE,NM144283-02-000SCREWG39-06-24B (4)
CLAMP10495-01-000 (4)SCREWG67-10-12B (4)
(BLU)SLIDEOUT #3 WIRE #1
DETAIL FB
CONNECTOR-WIRE,NM144283-02-000SCREWG39-06-24B (4)
(BLU)WIRE IN SIDEWALL
(BLU)TO RCP-SIDEWALL LOUNGE
(BLU)FROM RCP-2 EXT
(PUR)FROM LOAD CENTER
(YEL)FROM LOAD CENTER
(BLK)FROM LOAD CENTER
(GLD)FROM LOAD CENTER
(BRN)FROM LOAD CENTER
THROW IN #5(GLD)TO RCP-WASHER
THROW IN #4(YEL)TO RCP-3REFRIGERATOR
THROW IN #1(BRN)TO RCP-2(BDRM & GALLEY GFI
(BLK) WIREFROM SIDEWALLTO MICROWAVE
THROW IN #3(PUR)TO RCP-1BEDROOM TV
(GLD)SLIDEOUT #1 WIRE #5
(BLK)SLIDEOUT #1 WIRE #2
(BRN)SLIDEOUT #1 WIRE #1
(YEL)SLIDEOUT #1 WIRE #4
(PUR)SLIDEOUT #1 WIRE #3
DETAIL FA
CONNECTOR-WIRE,NM144283-02-000SCREWG39-06-24B (4)
(GLD-2)FROM LOAD CENTER
(GLD-2)SLIDEOUT #1 WIRE #6
THROW IN #6(GLD-2)TO DRYER
STACK PUR-2 AND GLD-2 ON BRACKET
*1
86
52
0 *
03-Jun-2014
![Page 8: If you lack the skills, tools or equipment to perform ... · rcp-b (det ca) a/c zone #1 gfi-1 can (blu) bath pur-2 from load center to galley slideout rcp-2 (blu) 110v connections](https://reader030.fdocuments.net/reader030/viewer/2022011809/5d28ccd888c99392328c8068/html5/thumbnails/8.jpg)
D
C
1
FIRST USED
8 3
B
28 1
DO NOT SCALE DRAWING
4
4DWGNO
3
TITLE:
C
6
B
7 5
PART NO
2
D
REV
5
AA
6
7
SHEET
14 J37F
WIRING INSTL-BODY,110V
186520
186520 *1
86
52
0 *
7
X-X
FORELECTRICAL
CALLOUTSSEE DWG NO.
121339-01-000
FOR ELECTRICALTORQUE
SPECIFICATIONSSEE DWG NO.
128783-01-000
110V CONNECTIONUNDER GALLEY
RCP-3REFRIGERATOR
110V CONNECTIONUNDER STOVE
2
BELOW FLOOR.
4
110V CONNECTION(LOCATED UNDER RT FRT ROOM)
RCP-2BED FRONT
5
GFI-1GALLEY 1
1
RCP-2COMPONENT 15
RCP-2BED REAR
ALL OUTLETS DOWN STREAM AND INCLUDING THIS OUTLETARE GROUND FAULT INTERUPT PROTECTED.
RCP-2EXT ENT CTR
RCP-1BEDROOM TV
3
2
110V CONNECTION(LOCATED BEHIND SOFA)
5
110V CONNECTION(LOCATED BELOW BED)
1
110V CONNECTIONSBELOW GALLEY
RCP-2A/V PREP
4 WIRE IN ROOF.
RCP-2EXTERIOR
3
3
RCP-2MAIN TV
3
2
2
RCP-2COMPONENT 2
RCP-2DINETTE
110V CONNECTION(LOCATED BELOW BED)
RCP-2SIDEWALL
FRONT
RCP-B FRONT(LOCATED IN RT
FRONT OVHD)
RCP-2OVHD
RCP-2REAR BATH
WIRE IN SIDEWALL.
GFI-1FRONT BATH
NOTES:
110V CONNECTION(LOCATED BELOW GALLEY)
RCP-2DINETTE 2
5
110V CONNECTION(LOCATED BELOW STOVE)
RCP-1DRYER
110V CONNECTIONSBELOW STOVE
2
SEE WIRING INSTL-TV/DVD FOR ADDITIONAL INFORMATION.
1 RCP-2DINETTE 1
110V CONNECTIONUNDER GALLEY
110V CONNECTIONUNDER STOVE
5
110V CONNECTIONUNDER STOVE2
110V CONNECTIONUNDER GALLEY
RCP-1WASHER14-2
RCP-2EXT TV 1DF
RCP-1 BED(LOCATED UNDER BED)
78J ELECTRICAL SYSTEM-50 AMP
265
1B1
78J
CODES/STANDARDS USA
2651B1
CODES/STANDARDS-CSA/CMVSS
1DF EXT TV ENTERTAINMENT CENTERLINE 1 (BLK) ROUTED THRU THIS CURRENT SENSOR
LINE 2 (RED) ROUTED THRU THIS CURRENT SENSOR6
7
L2
R3
R5
L1
L2
N
R1
R7
L1
FRONTA/C
RCP-BLANK,
ROOFA/C FRT
(LOCATEDIN RTBATHREAR
WALL)
EMSMODULE
7
6
WATERHEATER
WHT
GLD-2
GLD
3
BLK
GEN4X4BOX
6-3
GROUND
RED
6-3
RED
RED
1 BLK
BLKBLK
GENERATOR
8 GRN
GROUND
POWERCORD
12-2 14-2
12-2
4-3
4-3
12-2
14-2
14-2
14-2
14-2
10-2
INVERTER
14-2
MAIN PANEL
FROMINVERTER
14-210-2
TOINVERTER
REARA/C
3 RCP-BLANK,
ROOFA/C RR
(LOCATEDIN RTBATHREAR
WALL)
110V CONNECTIONUNDER STOVE
RCP-1MICROWAVE
2 110V CONNECTIONUNDER GALLEY
GFI-2GALLEY 2
SLIDEOUT #1WIRE #1
SLIDEOUT #3WIRE #1
SLIDEOUT #1WIRE #6
SLIDEOUT #1WIRE #4
THROW IN WIRE #6
3
SLIDEOUT #1WIRE #2
THROW IN WIRE #4
THROW IN WIRE #5
THROW IN WIRE #1
RCP-B TV'S(LOCATED IN RT
BATH REAR WALL)
SLIDEOUT #1WIRE #2
SLIDEOUT #1WIRE #5
SLIDEOUT #2WIRE #1
THROW IN WIRE #
3
03-Jun-2014