IBM Education Assistance for z/OS V2R1...Presentation Summary This presentation explained the...

17
© 2013 IBM Corporation Material is current as of June 2013 Item: I/O Autoconfiguration (zDAC) Stage 4 Element/Component: HCD/HCM IBM Education Assistance for z/OS V2R1

Transcript of IBM Education Assistance for z/OS V2R1...Presentation Summary This presentation explained the...

Page 1: IBM Education Assistance for z/OS V2R1...Presentation Summary This presentation explained the functional enhancements of the I/O path report to verify a configuration, along wih its

© 2013 IBM CorporationMaterial is current as of June 2013

Item: I/O Autoconfiguration (zDAC) Stage 4Element/Component: HCD/HCM

IBM Education Assistance for z/OS V2R1

Page 2: IBM Education Assistance for z/OS V2R1...Presentation Summary This presentation explained the functional enhancements of the I/O path report to verify a configuration, along wih its

Page 2 of 17 © 2013 IBM Corporation

Filename: zOS V2R1 HCD_HCM IO Autoconfiguration Stage 4.odp

Agenda

■ Overview - Verify configuration available by using zDAC■ Overview - Provide single point of failure information■ Usage & Invocation■ Interactions & Dependencies■ Presentation Summary■ Appendix

IBM Presentation Template Full Version

Page 3: IBM Education Assistance for z/OS V2R1...Presentation Summary This presentation explained the functional enhancements of the I/O path report to verify a configuration, along wih its

Page 3 of 17 © 2013 IBM Corporation

Filename: zOS V2R1 HCD_HCM IO Autoconfiguration Stage 4.odp

Overview – Verify configuration available by using zDAC

■ Problem Statement / Need Addressed –Verify configuration is available only, if Tivoli System Automation (TSA)

I/O Operations is installed and loaded. TSA I/O Operations is a priced product.

■ Solution–For processors capable of zDAC (z196 / z114) zDAC is used to

discover the active configuration, if TSA I/O Operations is not operational.

■ Benefit / Value –The prerequisite for TSA I/O Operations is removed.

IBM Presentation Template Full Version

Page 4: IBM Education Assistance for z/OS V2R1...Presentation Summary This presentation explained the functional enhancements of the I/O path report to verify a configuration, along wih its

Page 4 of 17 © 2013 IBM Corporation

Filename: zOS V2R1 HCD_HCM IO Autoconfiguration Stage 4.odp

Overview – Provide single point of failure information

■ Problem Statement / Need Addressed –There is no information on single points of failure (SPOF) for active

paths within HCD.■ Solution

–Integrate information provided by macro IOSSPOF into I/O path report.■ Benefit / Value

–Customers can easily identify single points of failure.

IBM Presentation Template Full Version

Page 5: IBM Education Assistance for z/OS V2R1...Presentation Summary This presentation explained the functional enhancements of the I/O path report to verify a configuration, along wih its

Page 5 of 17 © 2013 IBM Corporation

Filename: zOS V2R1 HCD_HCM IO Autoconfiguration Stage 4.odp

Usage & Invocation – similar to existing IO path reportIBM Presentation Template Full Version

● Use production IODF● Option 2 – activate or process

● Option 6 – activate or verify

● Option 4 or 5 - verify ..

● Identify target

Page 6: IBM Education Assistance for z/OS V2R1...Presentation Summary This presentation explained the functional enhancements of the I/O path report to verify a configuration, along wih its

Page 6 of 17 © 2013 IBM Corporation

Filename: zOS V2R1 HCD_HCM IO Autoconfiguration Stage 4.odp

Usage & Invocation – also via sysplex listIBM Presentation Template Full Version

● Use production IODF

● Option 2 activate or process configuration …

● Option 7 activate configuration sysplex-wide

Page 7: IBM Education Assistance for z/OS V2R1...Presentation Summary This presentation explained the functional enhancements of the I/O path report to verify a configuration, along wih its

Page 7 of 17 © 2013 IBM Corporation

Filename: zOS V2R1 HCD_HCM IO Autoconfiguration Stage 4.odp

Usage & Invocation – Informational message about zDAC being usedIBM Presentation Template Full Version

When TSA I/O Operations is not available, HCD tries to retrieve the active configuration via zDAC.

Page 8: IBM Education Assistance for z/OS V2R1...Presentation Summary This presentation explained the functional enhancements of the I/O path report to verify a configuration, along wih its

Page 8 of 17 © 2013 IBM Corporation

Filename: zOS V2R1 HCD_HCM IO Autoconfiguration Stage 4.odp

Usage & Invocation – resulting I/O path list IBM Presentation Template Full Version

Page 9: IBM Education Assistance for z/OS V2R1...Presentation Summary This presentation explained the functional enhancements of the I/O path report to verify a configuration, along wih its

Page 9 of 17 © 2013 IBM Corporation

Filename: zOS V2R1 HCD_HCM IO Autoconfiguration Stage 4.odp

Changed column STAT to indicate Single Point Of Failure

■ Operational (blank),

■ not operational (OFFL),

■ or unknown (UNKN).

■ If the report has been requested for the local system, it contains the status as returned from IOCINFO PATHMAP for the channel path in focus. For all operational paths (either via IOCINFO or I/O Operations API) a check for single point of failure is performed. The 4 letters map in following way

– POS 1: BLANK OR NUMBER BETWEEN 3 AND 8, (3: BOOK, 4: CAGE, 5:FAILOVER DOMAIN, 6: FANOUT, 7: DOMAIN, 8: SECONDARY STI/STI)

– POS 2: C, IF CU I/F SHARE SINGLE POINT OF FAILURE– POS 3: P, IF DEVICE HAS ONLY ONE PATH ONLINE– POS 4: S, IF ALL PATHS GO THROUGH ONE SWITCH

IBM Presentation Template Full Version

Page 10: IBM Education Assistance for z/OS V2R1...Presentation Summary This presentation explained the functional enhancements of the I/O path report to verify a configuration, along wih its

Page 10 of 17 © 2013 IBM Corporation

Filename: zOS V2R1 HCD_HCM IO Autoconfiguration Stage 4.odp

Column explanations

■ Sensed Data - CHT is the channel path type as returned ….from IOSCHPT. In case of discovery this information is only available, if the report is done for the local system.

■ Sensed Data - CUTYPE ….. if ZDAC was used: the type as specified in the node descriptor of the controller.

■ Sensed Data - DEVTYPE …. if ZDAC was used: the device type is the type found in the IODF (only filled, if the report is issued for the local system and if we have a token match with the active IODF)

■ Sensed Data - O … if ZDAC was used the state is the state returned from UCBSCAN. (only filled, if the report is issued for the local system and if we have a token match with the active IODF)

IBM Presentation Template Full Version

Page 11: IBM Education Assistance for z/OS V2R1...Presentation Summary This presentation explained the functional enhancements of the I/O path report to verify a configuration, along wih its

Page 11 of 17 © 2013 IBM Corporation

Filename: zOS V2R1 HCD_HCM IO Autoconfiguration Stage 4.odp

Usage & Invocation: Issue I/O path report via dialog

■ Option 3 Print or compare■ Option 1 Print configuration reports■ Select I/O path report■ Limit reports

Page 12: IBM Education Assistance for z/OS V2R1...Presentation Summary This presentation explained the functional enhancements of the I/O path report to verify a configuration, along wih its

Page 12 of 17 © 2013 IBM Corporation

Filename: zOS V2R1 HCD_HCM IO Autoconfiguration Stage 4.odp

Usage & Invocation – Informational message about zDAC being usedIBM Presentation Template Full Version

When TSA I/O Operations is not available, HCD tries to retrieve the active configuration via zDAC.

Page 13: IBM Education Assistance for z/OS V2R1...Presentation Summary This presentation explained the functional enhancements of the I/O path report to verify a configuration, along wih its

Page 13 of 17 © 2013 IBM Corporation

Filename: zOS V2R1 HCD_HCM IO Autoconfiguration Stage 4.odp

Commands

■ Batch invocation for IO pathreport is unchanged.

■ Sysplex name must be blankor local sysplex if TSA I/O operations is not available

e.g.

//REPORT1 EXEC PGM=CBDMGHCP,

// PARM=’REPORT,I,PROC1,PART1,MVS1,MYSYS,MYPLEX’

//HCDIODFS DD DSN=BWIN.IODF03.WORK,DISP=SHR

Page 14: IBM Education Assistance for z/OS V2R1...Presentation Summary This presentation explained the functional enhancements of the I/O path report to verify a configuration, along wih its

Page 14 of 17 © 2013 IBM Corporation

Filename: zOS V2R1 HCD_HCM IO Autoconfiguration Stage 4.odp

Messages (New and Updated)

■ CBDG375I I/O path is generated by means of IOS system discovery. Sensed data is limited to FICON attached storage devices on local system.

■ CBDG376I I/O path report using discovery is not possible. Reason: @1 Error information: @2 @3 @4

(sysplex not local, system not known, active IODF not available, dynamic changes not allowed ..)

■ CBDC096I Preparation of I/O path report in process - please wait ...

Page 15: IBM Education Assistance for z/OS V2R1...Presentation Summary This presentation explained the functional enhancements of the I/O path report to verify a configuration, along wih its

Page 15 of 17 © 2013 IBM Corporation

Filename: zOS V2R1 HCD_HCM IO Autoconfiguration Stage 4.odp

Interactions & Dependencies

■ User must be authorized to perform dynamic activation ■ Software Dependencies

–None.■ Hardware Dependencies

–IBM zEnterprise 196 or IBM zEnterprise 114 servers or IBM zEC 12■ Exploiters

–Systems programmers responsible for I/O definition

IBM Presentation Template Full Version

Page 16: IBM Education Assistance for z/OS V2R1...Presentation Summary This presentation explained the functional enhancements of the I/O path report to verify a configuration, along wih its

Page 16 of 17 © 2013 IBM Corporation

Filename: zOS V2R1 HCD_HCM IO Autoconfiguration Stage 4.odp

Presentation Summary

■ This presentation explained the functional enhancements of the I/O path report to verify a configuration, along wih its setup, usage and diagnostic information.

The functional enhancements are:– The usage of zDAC for discovery in case TSA I/O operations not being

available – Giving information about single points of failure (SPOF).

IBM Presentation Template Full Version

Page 17: IBM Education Assistance for z/OS V2R1...Presentation Summary This presentation explained the functional enhancements of the I/O path report to verify a configuration, along wih its

Page 17 of 17 © 2013 IBM Corporation

Filename: zOS V2R1 HCD_HCM IO Autoconfiguration Stage 4.odp

Appendix

■ Hardware Configuration Definition User's Guide, SC33-7988■ Hardware Configuration Manager User's Guide, SC33-7989 ■ Hardware Configuration Definition Messages, SC-7986■ Hardware Configuration Definition Planning, GA22-7525

■ HCD/HCM Homepage:–http://www.ibm.com/systems/z/os/zos/features/hcm/

■ HCD/HCM Contact:–[email protected]

IBM Presentation Template Full Version