HS-422 Series V ibr ation Sensor - Hansford Sensors Ltd. · 2013. 4. 14. · PUR Screened - length...

2

Transcript of HS-422 Series V ibr ation Sensor - Hansford Sensors Ltd. · 2013. 4. 14. · PUR Screened - length...

Page 1: HS-422 Series V ibr ation Sensor - Hansford Sensors Ltd. · 2013. 4. 14. · PUR Screened - length to be specified on order See 'How to order' table 100 Metres max. (10 bar) Ranges,

Tel: +44(0) 845 680 1957Fax: +44(0) 845 680 1958Email: [email protected]: www.hansfordsensors.com

Operating Temperature RangeSealingMaximum ShockEmissionsImmunity

-25 to 90 ºCIP685000 gEN61000-6-4:2007EN61000-6-2:2005

Case MaterialSensing Element/ConstructionMounting TorqueWeightCableMounting ThreadsSubmersible DepthOptions

Stainless SteelPZT/Compression8 Nm140 gms (nom)PUR Screened - length to be specified on orderSee 'How to order' table100 Metres max. (10 bar) Ranges, filters, other cable lengths,intrinsically safe

Mounted Base ResonanceAcceleration Ranges

Frequency ResponseIsolationMeasurement RangeTransverse SensitivityElectrical

10 kHz min.0-1 to 0-100 g RMS ± 10%Nominal 80 Hz at 22 °C10 Hz to 5 kHz at ±5% -ISO10816Base isolated50 g peakLess than 5%

Typical Applications

Low cost on-line means of monitoringwith the capability of interfacing directinto PLC, BMS or any 4-20mA inputmodule.Proven use in vibration monitoringfor offline applications using commerciallyavailable data collectors.

Protecting...Fans, Motors, Pumps, Compressors,Centrifuges, Conveyers, Air Handlers,Gearboxes, Rolls, Dryers, Presses,Cooling, HVAC, Spindles, Machine Tooling,Process Equipment and many more.

HS-422 Series Vibration SensorSubmersible, Good Resistance to Oil, 4-20mA 'g' Sensor for PLC Interface

Technical Performance

Environmental

Mechanical

Output CurrentSupply VoltageSettling TimeOutput ImpedanceCase Isolation

4-20 mA DC proportional to 'g'15 - 30 Volts DC (for 4-20 mA)2 secondsLoop Resistance 600 Ohms max. at 24 Volts>10 Ohms at 500 Volts8

Page 2: HS-422 Series V ibr ation Sensor - Hansford Sensors Ltd. · 2013. 4. 14. · PUR Screened - length to be specified on order See 'How to order' table 100 Metres max. (10 bar) Ranges,

HS-422 Series Vibration SensorDimensions

Frequency Response

Tel: +44(0) 845 680 1957Fax: +44(0) 845 680 1958Email: [email protected]: www.hansfordsensors.com

Ref: HS-422-SubC-OilResist-1111

Mounting of sensor to achieve good repeatable readings.Vibration sensor should be firmly fixed to a flat surface (spotface surface may be needed to be produced and cable anchoredto sensor body.)

TS187 Iss01

How to order

Please contact our Sales Office for information on sensor accessories (mounting studs, etc) and multichannel switch boxes.

We reserve the right to alter the specification of this product without prior notice.

Black

White