HP 16505A Prototype Analyzer Software Upgrade Installation...

24
© Copyright Hewlett-Packard Company 1997 All Rights Reserved Software Upgrade Installation Guide Publication Number 16505-92010 First Edition, June 1997 For Safety Information, Warranties, and Regulatory information, see the pages at the back of this guide. Prototype Analyzer HP 16505A

Transcript of HP 16505A Prototype Analyzer Software Upgrade Installation...

Page 1: HP 16505A Prototype Analyzer Software Upgrade Installation ...literature.cdn.keysight.com/litweb/pdf/16505-92010.pdf · This is the HP 16505A Prototype Analyzer Software Upgrade Installation

© Copyright Hewlett-Packard Company 1997All Rights Reserved

Software Upgrade

Installation Guide

Publication Number 16505-92010First Edition, June 1997

For Safety Information, Warranties, and Regulatoryinformation, see the pages at the back of this guide.

Prototype AnalyzerHP 16505A

Page 2: HP 16505A Prototype Analyzer Software Upgrade Installation ...literature.cdn.keysight.com/litweb/pdf/16505-92010.pdf · This is the HP 16505A Prototype Analyzer Software Upgrade Installation

Contents

Contents

Pages 4-7

Page 3

Pages 8-13

Page 14

Pages 15-20

Upgrade the HP 16500

Power-Down the HP 16505A

Upgrade the HP 16505A

Power-Up the HP 16505A SystemPower-Up the HP 16505A System

Installing AdditionalFeatures/Product SupportInstalling AdditionalFeatures/Product Support

2

Installing HP 16505A features/product support usingfloppy disks.

This Installation Guide covers two HP 16505Asoftware upgrade/install procedures:

Updating the HP 16500B/C logic analyzer with floppydisks and the HP 16505A prototype analyzer withCD-ROM and floppy disk.

The upgrade preserves all user files,directories, passwords, and network setup.The upgrade is done via local session.

Page 3: HP 16505A Prototype Analyzer Software Upgrade Installation ...literature.cdn.keysight.com/litweb/pdf/16505-92010.pdf · This is the HP 16505A Prototype Analyzer Software Upgrade Installation

Power-Down the HP 16505A

3

Power-Down the HP 16505A System

Back up your "user files".

(Rear Panels)

MyUser Files

Back up your files and powerdown the target and system.

HP 16500Standby PowerSwitch off.

Power-downthe target.

HP 16505AMain PowerSwitch off.

HEWLETTPACKARD

16500CLOGIC ANALYSIS SYSTEM

HP 16500Main PowerSwitch off.

43

2

5

It is always best practice to back up yourHP 16500 and HP 16505A user files viafloppy or network.

1

Page 4: HP 16505A Prototype Analyzer Software Upgrade Installation ...literature.cdn.keysight.com/litweb/pdf/16505-92010.pdf · This is the HP 16505A Prototype Analyzer Software Upgrade Installation

Upgrade the HP 16500

4

Insert the first software upgrade diskand power-up the HP 16500.

HEWLETTPACKARD

16500CLOGIC ANALYSIS SYSTEM

HP 16500C(or HP 16500B)HP 16500C(or HP 16500B) Main Power Switch

(Rear Panel)2

Upgrade the HP 16500

Standby PowerSwitch

Insert the first diskof the HP 16500

operating system.

Allow 30 secondsto boot up.

3

1

4

Only the HP 16500 should be turned onwhen installing the HP 16500 software.

Page 5: HP 16505A Prototype Analyzer Software Upgrade Installation ...literature.cdn.keysight.com/litweb/pdf/16505-92010.pdf · This is the HP 16505A Prototype Analyzer Software Upgrade Installation

Upgrade the HP 16500

5

Select the HP 16500 flexible disk drive and set the file operation field to Copy.

Load

Store

Autoload

Rename

Purge

FormatDisk

ChangeDirectory

Copy

DuplicateDisk

Configuration

Hard Disk

Flexible Disk

Utilities

Test

Page 6: HP 16505A Prototype Analyzer Software Upgrade Installation ...literature.cdn.keysight.com/litweb/pdf/16505-92010.pdf · This is the HP 16505A Prototype Analyzer Software Upgrade Installation

Upgrade the HP 16500

6

Set the source field to the wildcard symbol and set the destination directoryto \SYSTEM.

*

\ S Y S T E M

Clear

Done

*

Clear

Done

Page 7: HP 16505A Prototype Analyzer Software Upgrade Installation ...literature.cdn.keysight.com/litweb/pdf/16505-92010.pdf · This is the HP 16505A Prototype Analyzer Software Upgrade Installation

Upgrade the HP 16500

andpower-down the instrument.

7

Select Execute to begin copying.

*

Insert the next disk and repeat this stepuntil all the HP 16500 update files arecopied. Remove the last disk

fileexists...Overwrite?

Continue

Cancel

Page 8: HP 16505A Prototype Analyzer Software Upgrade Installation ...literature.cdn.keysight.com/litweb/pdf/16505-92010.pdf · This is the HP 16505A Prototype Analyzer Software Upgrade Installation

Upgrade the HP 16505A

8

Connect the CD-ROM drive tothe HP 16505A.

HP 16500C(or HP 16500B)HP 16500C(or HP 16500B)HP 16505A

CD-ROM DriveConnect the SCSI cable to theHP 16505A and the CD-ROM drive.

Disconnect theHigh Speed Interface Cablefrom the HP 16505A.

(Terminated)

2

1

Unterminated CD-ROM drives may corruptthe HP 16505A hard drive. CD-ROMdrives supplied by HP with Rev. A.01.30have been terminated internally.

Upgrade the HP 16505A

Page 9: HP 16505A Prototype Analyzer Software Upgrade Installation ...literature.cdn.keysight.com/litweb/pdf/16505-92010.pdf · This is the HP 16505A Prototype Analyzer Software Upgrade Installation

Upgrade the HP 16505A

9

Set the SCSI address and connect the power cable.

1

2

Set the SCSI address to address 4.

Connect the power cable.

(CD-ROM Power Switch.)

23 4 5 6

1

CD-ROM drives supplied by HP withRev. A.01.30 have the SCSI addressset to 4 at the factory. Ensure that theswitch settings correspond to thisdrawing.

Page 10: HP 16505A Prototype Analyzer Software Upgrade Installation ...literature.cdn.keysight.com/litweb/pdf/16505-92010.pdf · This is the HP 16505A Prototype Analyzer Software Upgrade Installation

Upgrade the HP 16505A

10

Turn on the CD-ROM drive and the HP 16505A.

Monitor Main PowerSwitchMonitor Main PowerSwitch

2

1CD-ROM power switch.

(Rear Panel)

HP 16505AMain Power SwitchHP 16505AMain Power Switch

3

Page 11: HP 16505A Prototype Analyzer Software Upgrade Installation ...literature.cdn.keysight.com/litweb/pdf/16505-92010.pdf · This is the HP 16505A Prototype Analyzer Software Upgrade Installation

Upgrade the HP 16505A

11

Insert the CD and the flexible disk into the drives.

HP 16505A CD InstallUtility DiskHP 16505A CD InstallUtility Disk

HP 16505A CD

Page 12: HP 16505A Prototype Analyzer Software Upgrade Installation ...literature.cdn.keysight.com/litweb/pdf/16505-92010.pdf · This is the HP 16505A Prototype Analyzer Software Upgrade Installation

Chapter Start TitleChapter Start Title

Upgrade the HP 16505A

12

Click on the appropriate fields to begin loading the software upgrade.

HP 16505A - Session Manager

Page 13: HP 16505A Prototype Analyzer Software Upgrade Installation ...literature.cdn.keysight.com/litweb/pdf/16505-92010.pdf · This is the HP 16505A Prototype Analyzer Software Upgrade Installation

Upgrading the HP 16505A

13

Upon completion, turn off the system and reconnect theHigh Speed Interface Cable.

HP 16500C(or HP 16500B)HP 16500C(or HP 16500B)HP 16505A

CD-ROM DriveCD-ROM Drive

Connect the High Speed Interface Cableto the HP 16505A.

3

Turn offthe system.1

Disconnect theSCSI Cablefrom the HP 16505A.

2

Page 14: HP 16505A Prototype Analyzer Software Upgrade Installation ...literature.cdn.keysight.com/litweb/pdf/16505-92010.pdf · This is the HP 16505A Prototype Analyzer Software Upgrade Installation

Power-Up the HP 16505A

14

UpgradeComplete

Power-Up the HP 16505A System

HEWLETTPACKARD

16500CLOGIC ANALYSIS SYSTEM

Start upOrder

HP 16500Main PowerSwitch

HP 16500Main PowerSwitch

1

2 HP 16500Standby PowerSwitch

HP 16500Standby PowerSwitch

3 Wait...The HP 16500 must beallowed to fully boot upbefore you turn on theHP 16505A and themonitor.

Monitor Main PowerSwitchMonitor Main PowerSwitch4

HP 16505AMain Power SwitchHP 16505AMain Power Switch

Power up the Target.

5

6

Page 15: HP 16505A Prototype Analyzer Software Upgrade Installation ...literature.cdn.keysight.com/litweb/pdf/16505-92010.pdf · This is the HP 16505A Prototype Analyzer Software Upgrade Installation

Installing Additional HP 16505A Features/Product Support

15

Installing Additional HP 16505A Features/Product Support

Only the HP 16500 should be turned onwhen installing the HP 16500 software.

HP 16500(B or C)Main PowerSwitch

HP 16500(B or C)Main PowerSwitch

Power-downthe target andthe HP 16505A.

Power-downthe target andthe HP 16505A.

Allow 30 secondsto boot up.Allow 30 secondsto boot up.

Insert the first diskof the HP 16500operating system.

Insert the first diskof the HP 16500operating system.

HP 16500Standby PowerSwitch

HP 16500Standby PowerSwitch 3

4

5

2

1

Start upOrder

Page 16: HP 16505A Prototype Analyzer Software Upgrade Installation ...literature.cdn.keysight.com/litweb/pdf/16505-92010.pdf · This is the HP 16505A Prototype Analyzer Software Upgrade Installation

Installing Additional Features/Product Support

16

Select the HP 16500 flexible disk drive and set the file operation field to Copy.

Load

Store

Autoload

Rename

Purge

FormatDisk

ChangeDirectory

Copy

DuplicateDisk

Configuration

Hard DiskHard Disk

Flexible Disk

Utilities

Test

Page 17: HP 16505A Prototype Analyzer Software Upgrade Installation ...literature.cdn.keysight.com/litweb/pdf/16505-92010.pdf · This is the HP 16505A Prototype Analyzer Software Upgrade Installation

Installing Additional Features/Product Support

17

Set the source field to the wildcard symbol and set the destination directoryto \SYSTEM.

*

\ S Y S T E M

Clear

Done

*

Clear

Done

Page 18: HP 16505A Prototype Analyzer Software Upgrade Installation ...literature.cdn.keysight.com/litweb/pdf/16505-92010.pdf · This is the HP 16505A Prototype Analyzer Software Upgrade Installation

Installing Additional Features/Product Support

18

Select Execute to begin copying.

*

Insert the next disk andrepeat this step until allHP 16500 files are copied.

Insert the next disk andrepeat this step until allHP 16500 files are copied.

fileexists...Overwrite?

Continue

Cancel

Page 19: HP 16505A Prototype Analyzer Software Upgrade Installation ...literature.cdn.keysight.com/litweb/pdf/16505-92010.pdf · This is the HP 16505A Prototype Analyzer Software Upgrade Installation

Installing Additional Features/Product Support

19

Turn on the HP 16505A system and insert the Product/Features disk(s).

Cycle the HP 16500Standby Power SwitchCycle the HP 16500Standby Power Switch

Monitor MainPower SwitchMonitor MainPower Switch

Insert theProduct/Features Disk

Insert theProduct/Features Disk

The HP 16500 must beallowed to fully boot up.

2

3

Prototype AnalyzerMain Power SwitchPrototype AnalyzerMain Power Switch

Wait...

Start upOrder

1

4

5

Cycle the power on the HP 16500 torestart the system with the new filesinstalled in the previous pages. (The mainpower switch on the HP 16500 rear panelmay remain in the ON position.)

Page 20: HP 16505A Prototype Analyzer Software Upgrade Installation ...literature.cdn.keysight.com/litweb/pdf/16505-92010.pdf · This is the HP 16505A Prototype Analyzer Software Upgrade Installation

Installing Additional Features/Product Support

20

Click on the appropriate fields to begin the file installation.

HP 16505A - Session Manager

UpgradeComplete

Upon completion, reboot the HP 16505A system(page 14) and power-up the target.

Page 21: HP 16505A Prototype Analyzer Software Upgrade Installation ...literature.cdn.keysight.com/litweb/pdf/16505-92010.pdf · This is the HP 16505A Prototype Analyzer Software Upgrade Installation

Copyright Hewlett-PackardCompany 1997All Rights Reserved.

Reproduction, adaptation, ortranslation without prior writtenpermission is prohibited, exceptas allowed under the copyrightlaws.

The information contained in thisdocument is subject to changewithout notice.

Use, duplication or disclosure bythe U.S.Government is subject torestrictions as set forth insubparagraph (c)(1)(ii) of theRights in Technical Data andComputer Software clause atDFARS 252.227-7013 for DODagencies, and subparagraphs(c)(1) and (c)(2) of theCommercial Computer SoftwareRestricted Rights clause at FAR52.227-19 for other agencies.

Hewlett-Packard Company3000 Hanover StreetPalo Alto, California 94304U.S.A.

Hewlett-Packard makes no

warranty of any kind with

regard to this material,

including, but not limited to, the

implied warranties of

merchantability or fitness for a

particular purpose.

Hewlett-Packard shall not beliable for errors contained hereinor for damages in connectionwith the furnishing, performance,or use of this material.

Hewlett-PackardP.O. Box 21971900 Garden of the Gods RoadColorado Springs, CO. 80901

This apparatus has been designedand tested in accordance with IECPublication 1010, SafetyRequirements for MeasuringApparatus, and has been suppliedin a safe condition. This is aSafety Class I instrument(provided with terminal forprotective earthing). Beforeapplying power, verify that thecorrect safety precautions aretaken (see the followingwarnings). In addition, note theexternal markings on theinstrument that are describedunder "Safety Symbols."

Before turning on theinstrument, you must connect theprotective earth terminal of theinstrument to the protectiveconductor of the (mains) powercord. The mains plug shall onlybe inserted in a socket outletprovided with a protective earthcontact. You must not negate theprotective action by using anextension cord (power cable)without a protective conductor(grounding). Grounding oneconductor of a two-conductoroutlet is not sufficient protection.

Only fuses with the requiredrated current, voltage, andspecified type (normal blow, timedelay, etc.) should be used. Donot use repaired fuses or short-circuited fuseholders. To do socould cause a shock or firehazard.

Service instructions are fortrained service personnel. Toavoid dangerous electric shock,do not perform any service unlessqualified to do so. Do notattempt internal service oradjustment unless another person,capable of rendering first aid andresuscitation, is present.

If you energize this instrumentby an auto transformer (forvoltage reduction), make sure thecommon terminal is connected tothe earth terminal of the powersource.

Whenever it is likely that theground protection is impaired,you must make the instrumentinoperative and secure it againstany unintended operation.

Do not operate the instrumentin the presence of flammablegasses or fumes. Operation ofany electrical instrument in suchan environment constitutes adefinite safety hazard.

Do not install substitute parts orperform any unauthorizedmodification to the instrument.

Capacitors inside the instrumentmay retain a charge even if theinstrument is disconnected fromits source of supply.

The Caution sign denotes ahazard. It calls attention to anoperating procedure, practice, orthe like, which, if not correctlyperformed or adhered to, couldresult in damage to or destructionof part or all of the product. Donot proceed beyond a Cautionsymbol until the indicatedconditions are fully understood ormet.

Earth terminal symbol: Used toindicate a circuit commonconnected to grounded chassis.

Hazardous voltage symbol.

Instruction manual symbol: theproduct is marked with thissymbol when it is necessary foryou to refer to the instructionmanual in order to protect againstdamage to the product.

Use caution when exposing orhandling the CRT. Handling orreplacing the CRT shall be doneonly by qualified maintenancepersonnel.

The Warning sign denotes ahazard. It calls attention to aprocedure, practice, or the like,which, if not correctly performedor adhered to, could result inpersonal injury. Do not proceedbeyond a Warning sign until theindicated conditions are fullyunderstood and met.

C

WARNING

CAUTION

Page 22: HP 16505A Prototype Analyzer Software Upgrade Installation ...literature.cdn.keysight.com/litweb/pdf/16505-92010.pdf · This is the HP 16505A Prototype Analyzer Software Upgrade Installation

No other warranty is

expressed or implied.

Hewlett-Packard specifically

disclaims the implied

warranties of

merchantability or fitness for

The remedies provided herein arethe buyer's sole and exclusiveremedies. Hewlett-Packard shallnot be liable for any direct,indirect, special, incidental, orconsequential damages, whetherbased on contract, tort, or any otherlegal theory.

Product maintenance agreementsand other customer assistanceagreements are available forHewlett-Packard products. For anyassistance, contact your nearestHewlett-Packard Sales Office.

Hewlett-Packard Companycertifies that this product met itspublished specifications at the timeof shipment from the factory.Hewlett-Packard further certifiesthat its calibration measurementsare traceable to the United StatesNational Institute of Standards andTechnology, to the extent allowedby the Institute's calibrationfacility, and to the calibrationfacilities of other InternationalStandards Organization members.

This is the HP 16505A PrototypeAnalyzer Software UpgradeInstallation Guide

Publication number 16505-92010Printed in USA.Edition dates are as follows:

First edition, June 1997

New editions are completerevisions of the manual. Updatepackages, which are issuedbetween editions, containadditional and replacement pagesto be merged into the manual byyou. The dates on the title pagechange only when a new edition ispublished. A software or firmwarecode may be printed before thedate. This code indicates theversion level of the software orfirmware of this product at the timethe manual or update was issued.Many product updates do notrequire manual changes; and,conversely, manual correctionsmay be done withoutaccompanying product changes.Therefore, do not expect a one-to-one correspondence betweenproduct updates and manualupdates.

The following list of pagesgives the date of the currentedition and of any changedpages to that edition.

All pages original edition

This Hewlett-Packard product has awarranty against defects in materialand workmanship for a period ofone year from date of shipment.During the warranty period,Hewlett-Packard Company will, atits option, either repair or replaceproducts that prove to be defective.For warranty service or repair, thisproduct must be returned to aservice facility designated byHewlett-Packard. For productsreturned to Hewlett-Packard forwarranty service, the Buyer shallprepay shipping charges to Hewlett-Packard and Hewlett-Packard shallpay shipping charges to return theproduct to the Buyer. However, theBuyer shall pay all shippingcharges, duties, and taxes forproducts returned to Hewlett-Packard from another country.Hewlett-Packard warrants that itssoftware and firmware designatedby Hewlett-Packard for use with aninstrument will execute itsprogramming instructions whenproperly installed on thatinstrument. Hewlett-Packard doesnot warrant that the operation of theinstrument software, or firmwarewill be uninterrupted or error free.

The foregoing warranty shall notapply to defects resulting fromimproper or inadequatemaintenance by the Buyer, Buyer-supplied software or interfacing,unauthorized modification ormisuse, operation outside of theenvironmental specifications for theproduct, or improper sitepreparation or maintenance.

The manufacturer of the CD-ROMdrive is responsible for post-salessupport and warranty for the CD-ROM drive.

Page 23: HP 16505A Prototype Analyzer Software Upgrade Installation ...literature.cdn.keysight.com/litweb/pdf/16505-92010.pdf · This is the HP 16505A Prototype Analyzer Software Upgrade Installation
Page 24: HP 16505A Prototype Analyzer Software Upgrade Installation ...literature.cdn.keysight.com/litweb/pdf/16505-92010.pdf · This is the HP 16505A Prototype Analyzer Software Upgrade Installation