Heat Transfer Simulation for the Welding of the T-Section
![Page 2: Heat Transfer Simulation for the Welding of the T-Section.](https://reader035.fdocuments.net/reader035/viewer/2022062305/5697bffb1a28abf838cc0d37/html5/thumbnails/2.jpg)
Boundary Conditions
• This model was run with a Gaussian heat flux distribution for the weld zone as used in other studies.
• The weld heat transfer model used is a combination of rapid heat flux followed with constant (melt) temperature imposed at the weld zone as verified by experiments.
![Page 3: Heat Transfer Simulation for the Welding of the T-Section.](https://reader035.fdocuments.net/reader035/viewer/2022062305/5697bffb1a28abf838cc0d37/html5/thumbnails/3.jpg)
Boundary Conditions (cont’d)
• The heat transfer coefficients on all surfaces were calculated using the vertical and horizontal plate correlations available in literature.
• Radiation boundary condition was applied where temperature was high.
![Page 4: Heat Transfer Simulation for the Welding of the T-Section.](https://reader035.fdocuments.net/reader035/viewer/2022062305/5697bffb1a28abf838cc0d37/html5/thumbnails/4.jpg)
MATERIAL K THERMAL
COND.W / m K
DENSITY
Kg / m3
CpSPECIFIC
HEATJ / Kg K
TYPE OF
SUB DOMAIN
Stainless SteelAISI 316
13.4 8238 468 T-section and outer can
Pure Copper 401 8933 385 Cladding and Conductors
Glass fine fiberOrganic bonded
0.036 105 795 Gap between can and copper
cladding
Kapton type 100 HN film
0.12 1.42 x 103 1.09 x 103 Ground or Outer Insulation
Kapton +Glass Layers
0.042 631 913 Inner Insulation over Copper Conductors
Properties TableAll Properties have been taken at 300 K
![Page 5: Heat Transfer Simulation for the Welding of the T-Section.](https://reader035.fdocuments.net/reader035/viewer/2022062305/5697bffb1a28abf838cc0d37/html5/thumbnails/5.jpg)
T- Section: Stainless Steel
Gap: Glass
Cladding: Pure Copper
Outer Insl: Kapton
Inner Insl: Kapton+Glass
Conductors: Pure Copper
![Page 6: Heat Transfer Simulation for the Welding of the T-Section.](https://reader035.fdocuments.net/reader035/viewer/2022062305/5697bffb1a28abf838cc0d37/html5/thumbnails/6.jpg)
All Dimensions are in inches.All temperatures are in Kelvin, except the graphical presentation of temperature with time where Celsius is used for easier comparison with other (experimental) results.
![Page 7: Heat Transfer Simulation for the Welding of the T-Section.](https://reader035.fdocuments.net/reader035/viewer/2022062305/5697bffb1a28abf838cc0d37/html5/thumbnails/7.jpg)
![Page 8: Heat Transfer Simulation for the Welding of the T-Section.](https://reader035.fdocuments.net/reader035/viewer/2022062305/5697bffb1a28abf838cc0d37/html5/thumbnails/8.jpg)
![Page 9: Heat Transfer Simulation for the Welding of the T-Section.](https://reader035.fdocuments.net/reader035/viewer/2022062305/5697bffb1a28abf838cc0d37/html5/thumbnails/9.jpg)
Gaussian heat flux imposed at the weld zone
0 < time < 0.01 secs
![Page 10: Heat Transfer Simulation for the Welding of the T-Section.](https://reader035.fdocuments.net/reader035/viewer/2022062305/5697bffb1a28abf838cc0d37/html5/thumbnails/10.jpg)
Addition of heat flux
![Page 11: Heat Transfer Simulation for the Welding of the T-Section.](https://reader035.fdocuments.net/reader035/viewer/2022062305/5697bffb1a28abf838cc0d37/html5/thumbnails/11.jpg)
Constant temperature imposed at the weld zone
0.01 < time < 1.5 secs
![Page 12: Heat Transfer Simulation for the Welding of the T-Section.](https://reader035.fdocuments.net/reader035/viewer/2022062305/5697bffb1a28abf838cc0d37/html5/thumbnails/12.jpg)
Constant Temperature
![Page 13: Heat Transfer Simulation for the Welding of the T-Section.](https://reader035.fdocuments.net/reader035/viewer/2022062305/5697bffb1a28abf838cc0d37/html5/thumbnails/13.jpg)
Constant Temperature
![Page 14: Heat Transfer Simulation for the Welding of the T-Section.](https://reader035.fdocuments.net/reader035/viewer/2022062305/5697bffb1a28abf838cc0d37/html5/thumbnails/14.jpg)
Constant Temperature
![Page 15: Heat Transfer Simulation for the Welding of the T-Section.](https://reader035.fdocuments.net/reader035/viewer/2022062305/5697bffb1a28abf838cc0d37/html5/thumbnails/15.jpg)
Constant Temperature
![Page 16: Heat Transfer Simulation for the Welding of the T-Section.](https://reader035.fdocuments.net/reader035/viewer/2022062305/5697bffb1a28abf838cc0d37/html5/thumbnails/16.jpg)
Natural Cooling with Convection and Radiation
1.5 < time < 60 secs
![Page 17: Heat Transfer Simulation for the Welding of the T-Section.](https://reader035.fdocuments.net/reader035/viewer/2022062305/5697bffb1a28abf838cc0d37/html5/thumbnails/17.jpg)
Natural Cooling
![Page 18: Heat Transfer Simulation for the Welding of the T-Section.](https://reader035.fdocuments.net/reader035/viewer/2022062305/5697bffb1a28abf838cc0d37/html5/thumbnails/18.jpg)
Natural Cooling
![Page 19: Heat Transfer Simulation for the Welding of the T-Section.](https://reader035.fdocuments.net/reader035/viewer/2022062305/5697bffb1a28abf838cc0d37/html5/thumbnails/19.jpg)
Natural Cooling
![Page 20: Heat Transfer Simulation for the Welding of the T-Section.](https://reader035.fdocuments.net/reader035/viewer/2022062305/5697bffb1a28abf838cc0d37/html5/thumbnails/20.jpg)
Natural Cooling
![Page 21: Heat Transfer Simulation for the Welding of the T-Section.](https://reader035.fdocuments.net/reader035/viewer/2022062305/5697bffb1a28abf838cc0d37/html5/thumbnails/21.jpg)
Natural Cooling
![Page 22: Heat Transfer Simulation for the Welding of the T-Section.](https://reader035.fdocuments.net/reader035/viewer/2022062305/5697bffb1a28abf838cc0d37/html5/thumbnails/22.jpg)
Natural Cooling
![Page 23: Heat Transfer Simulation for the Welding of the T-Section.](https://reader035.fdocuments.net/reader035/viewer/2022062305/5697bffb1a28abf838cc0d37/html5/thumbnails/23.jpg)
Natural Cooling
![Page 24: Heat Transfer Simulation for the Welding of the T-Section.](https://reader035.fdocuments.net/reader035/viewer/2022062305/5697bffb1a28abf838cc0d37/html5/thumbnails/24.jpg)
Natural Cooling
![Page 25: Heat Transfer Simulation for the Welding of the T-Section.](https://reader035.fdocuments.net/reader035/viewer/2022062305/5697bffb1a28abf838cc0d37/html5/thumbnails/25.jpg)
Natural Cooling
![Page 26: Heat Transfer Simulation for the Welding of the T-Section.](https://reader035.fdocuments.net/reader035/viewer/2022062305/5697bffb1a28abf838cc0d37/html5/thumbnails/26.jpg)
Natural Cooling
![Page 27: Heat Transfer Simulation for the Welding of the T-Section.](https://reader035.fdocuments.net/reader035/viewer/2022062305/5697bffb1a28abf838cc0d37/html5/thumbnails/27.jpg)
Next few slides show temperature
profile at these specific locations
1-2 Glass+Kapton
2-3 Kapton
3-4 Cu cladding
4-5 Glass
6 Highest temp point
during welding
![Page 28: Heat Transfer Simulation for the Welding of the T-Section.](https://reader035.fdocuments.net/reader035/viewer/2022062305/5697bffb1a28abf838cc0d37/html5/thumbnails/28.jpg)
0 10 20 30 40 50 60
0
100
200
300
400
500
600
700
800
Time in seconds
Tem
pera
ture
in C
Temperature at various Locations
1
2 3
4
5
![Page 29: Heat Transfer Simulation for the Welding of the T-Section.](https://reader035.fdocuments.net/reader035/viewer/2022062305/5697bffb1a28abf838cc0d37/html5/thumbnails/29.jpg)
![Page 30: Heat Transfer Simulation for the Welding of the T-Section.](https://reader035.fdocuments.net/reader035/viewer/2022062305/5697bffb1a28abf838cc0d37/html5/thumbnails/30.jpg)
Conclusions• The temperatures reached in this model are higher
than in the two test cases because the thickness of steel sheet used here is 0.04” compared to the 0.06” used earlier.
• The temperature results here (2D) are higher (at least by 15% based on experiments) when compared with a 3D model.
• The maximum temperature at the edge of glass insulation observed here is 750 °C. The lower estimate for the melting of fiberglass is 820 °C.