Heat Pump Air Curtain 7 Day Controller RBC-AMS41E€¦ · Toshiba 24 hour Technical Helpline 0870...

2
Note 1: The remote controller wire should not be bundled with other wires (mains, etc.), or installed with other wires in the same conduit, as malfunction may result. Note 2: Install the remote controller away from sourc- es of electrical interference and electromagnetic fields. Note 3: If electrical inter- ference is unavoidable, countermeasures such as appropriate filtering should be employed. Connect the wires of the remote controller follow- ing the terminal number- ing convention of the air curtain to prevent miswir- ing. Do not apply 230v AC mains voltage to the re- mote controller as it will be damaged. The RBC-AMS41E is a general controller and in- cludes features that are not utilised by Envirotec air curtains. For Toshiba technical en- quiries and Support, or if fault codes appear on the controller display, switch the air curtain off at circuit breaker or isolator and contact: Toshiba 24 hour Technical Helpline 0870 843 0333. Heat Pump Air Curtain 7 Day Controller RBC-AMS41E If requested, the Air Curtain can be supplied with a special 7 day hard wired remote controller, model RBC-AMS41E, manufactured by Toshiba to match their outside evaporator unit. The 7 day hard wired remote controller can control an individual air curtain or a group of 8 air curtains. The remote controller allows the operating parameters to be set for the indoor unit. It also allows faults to be displayed and unit configurations to be set up. Installation For full owner’s manual, please visit the Toshiba website at: http://www.toshiba-aircon.co.uk/products/controls/view/ standard-remote-rbc-ams41e

Transcript of Heat Pump Air Curtain 7 Day Controller RBC-AMS41E€¦ · Toshiba 24 hour Technical Helpline 0870...

Page 1: Heat Pump Air Curtain 7 Day Controller RBC-AMS41E€¦ · Toshiba 24 hour Technical Helpline 0870 843 0333. Heat Pump Air Curtain 7 Day Controller RBC-AMS41E If requested, the Air

Note 1: The remote controller wire should not be bundled with other wires (mains, etc.), or installed with other wires in the same conduit, as malfunction may result.

Note 2: Install the remote controller away from sourc-es of electrical interference and electromagnetic fields.

Note 3: If electrical inter-ference is unavoidable, countermeasures such as appropriate filtering should be employed.

Connect the wires of the remote controller follow-ing the terminal number-ing convention of the air

curtain to prevent miswir-ing. Do not apply 230v AC mains voltage to the re-mote controller as it will be damaged.

The RBC-AMS41E is a general controller and in-cludes features that are not utilised by Envirotec air curtains.

For Toshiba technical en-quiries and Support, or if fault codes appear on the controller display, switch the air curtain off at circuit breaker or isolator and contact:

Toshiba 24 hour Technical Helpline0870 843 0333.

Heat Pump Air Curtain 7 Day ControllerRBC-AMS41E

If requested, the Air Curtain can be supplied with a special 7 day hard wired remote controller, model RBC-AMS41E, manufactured by Toshiba to match their outside evaporator unit.

The 7 day hard wired remote controller can

control an individual air curtain or a group of 8 air curtains. The remote controller allows the operating parameters to be set for the indoor unit. It also allows faults to be displayed and unit configurations to be set up.

Installation

For full owner’s manual, please visit the Toshiba website at:

http://www.toshiba-aircon.co.uk/products/controls/view/standard-remote-rbc-ams41e

Page 2: Heat Pump Air Curtain 7 Day Controller RBC-AMS41E€¦ · Toshiba 24 hour Technical Helpline 0870 843 0333. Heat Pump Air Curtain 7 Day Controller RBC-AMS41E If requested, the Air

Toshiba RBC-AMS41E, Issue A - 2016© Envirotec Ltd. Due to a policy of continuous development and improvement, the right is reserved to supply products which may differ from those described in this publication.