Healthe Air 2.0 User Guide · 2020. 11. 11. · Healthe Inc. | 3905 W Eau Gallie blvd, Suite 101,...

5
life in a different light Healthe Air 2.0 User Guide

Transcript of Healthe Air 2.0 User Guide · 2020. 11. 11. · Healthe Inc. | 3905 W Eau Gallie blvd, Suite 101,...

Page 1: Healthe Air 2.0 User Guide · 2020. 11. 11. · Healthe Inc. | 3905 W Eau Gallie blvd, Suite 101, Melbourne, FL 32941 | 877.999.5742 | healtheinc.com 3 2X2 AND 2X4 INSTALLATION Before

life in a different light

Healthe Air 2.0 User Guide

Page 2: Healthe Air 2.0 User Guide · 2020. 11. 11. · Healthe Inc. | 3905 W Eau Gallie blvd, Suite 101, Melbourne, FL 32941 | 877.999.5742 | healtheinc.com 3 2X2 AND 2X4 INSTALLATION Before

Healthe Inc. | 3905 W Eau Gallie blvd, Suite 101, Melbourne, FL 32941 | 877.999.5742 | healtheinc.com

2

IMPORTANT SAFEGUARDS

READ AND FOLLOW ALL SAFETY INSTRUCTIONS

When using electrical equipment, basic safety precautions should always be followed including the following:

WARNING: Risk of Electric Shock. Disconnect power at the fuse or circuit breaker before installing or servicing.

WARNING: Risk of fire or electric shock. This product installation requires knowledge of luminaires electrical systems. Installation should be performed only by a qualified electrician in accordance with the National Electrical Code and local building codes.

WARNING: Risk of fire or electric shock. The input voltage rating of this product is 120–277VAC. AC line voltage must meet the product input voltage rating before installation.

WARNING: Risk of fire or electric shock. ONLY install this product in ceilings that have the construction features and dimensions shown in the product documents and/or drawings.

WARNING: Risk of fire or electric shock. Do not make or alter any open holes in an enclosure of wiring or electrical components. Only those open holes indicated in the photographs and/or drawings may be used during installation.

WARNING: Risk of electric shock. To prevent wiring damage or abrasion, do not expose wiring to edges of sheet metal or other sharp objects.

WARNING: Risk of Electric Shock. Do not use or proceed with installation when enclosure is broken.

CAUTION: Do not use abrasive materials, glass cleaners or other solvents on cover plate or lens. Use of these substances may cause the damage to the product. For cleaning purpose, use a mild soap solution.

SAVE THESE INSTRUCTIONS

FDA DISCLAIMER – FOOD AND DRUG ADMINISTRATION STATEMENT: The statements made within this manual have not been evaluated by the U.S. Food and Drug Administration. This product is not intended to diagnose, treat, cure or prevent any disease.

NOT FOR SALE OR DISTRIBUTION IN HAWAII, INDIANA, NEW MEXICO, WYOMING, OKLAHOMA, COLORADO, WASHINGTON DC, AND US TERRITORY OF PUERTO RICO.

WARRANTY

Limited Warranty Period: This lamp has a 5-year Limited Warranty. If this Product fails to operate during the Warranty Period due to a defect in materials or workmanship, please follow the instructions below to view complete warranty details or to submit a warranty claim.Visit www.healtheinc.com/pages/warranties for complete warranty information, or call Customer Support at 1-877-999-5742 to submit warranty claims or request a resolution to a consumer concern.

Safety Information

Page 3: Healthe Air 2.0 User Guide · 2020. 11. 11. · Healthe Inc. | 3905 W Eau Gallie blvd, Suite 101, Melbourne, FL 32941 | 877.999.5742 | healtheinc.com 3 2X2 AND 2X4 INSTALLATION Before

Healthe Inc. | 3905 W Eau Gallie blvd, Suite 101, Melbourne, FL 32941 | 877.999.5742 | healtheinc.com

3

2X2 AND 2X4 INSTALLATION

Before starting, make sure POWER is turned off at the main circuit breaker to the location that you are installing the Healthe Air 2.0. Remove existing troffer if applicable.NOTE: The Healthe Air 2.0 is designed to placed onto a grid ceiling.

Installation Guide

2. Gently place Air 2.0 in the T-Grid ceiling making sure each tab is secured onto the T-bar grid.

1. Place Healthe Air 2.0 in an open work space and pull out the (4) T-Grid mounting tabs to 90° as shown

3. Bend each T-Grid mounting tab against T-bar grid and fasten with a #8 sheet metal screw (screw not included) to secure Troffer to T-bar grid in accordance to National Electrical Code and local building codes.

4. Attach hanger wires from the building ceiling structure to the Air 2.0 in accordance with local building and safety code requirements.

6. Make all the electrical connections with wire nuts from AC power supply cable to the Air 2.0, connecting black to black, white to white, and green to green. For the 0-10V dimmer wiring, connect grey to grey and violet to violet from dimmer to the Air 2.0. (See Wiring Diagram on page 4.)

7. After all electrical connections are made, attach the power conduit plate back onto the Air 2.0 to complete installation.

5. Remove power conduit plate, feed power supply cable into the conduit plate, and install with appropriate electrical fitting.

Page 4: Healthe Air 2.0 User Guide · 2020. 11. 11. · Healthe Inc. | 3905 W Eau Gallie blvd, Suite 101, Melbourne, FL 32941 | 877.999.5742 | healtheinc.com 3 2X2 AND 2X4 INSTALLATION Before

Healthe Inc. | 3905 W Eau Gallie blvd, Suite 101, Melbourne, FL 32941 | 877.999.5742 | healtheinc.com

4

WIRING DIAGRAM

0–10 V Dimmer

Healthe Air 2.02x2

(+) Violet(-) Grey

0–10 V Signals

Ground (Green)

AC Input —Line (Black)

AC Input—Neutral (White)

Installation Guide

Page 5: Healthe Air 2.0 User Guide · 2020. 11. 11. · Healthe Inc. | 3905 W Eau Gallie blvd, Suite 101, Melbourne, FL 32941 | 877.999.5742 | healtheinc.com 3 2X2 AND 2X4 INSTALLATION Before

Service Guide

Routine maintenance of key components of the Healthe Air 2.0 will help sustain the product’s smooth performance and minimize downtime. For optimal performance of the HEPA/Charcoal filter, it should be inspected monthly and replaced every six to twelve months. For the UVC LED module included as part of the Healthe Air 2.0, it should be replaced after 3,000 hours of operations. Please refer to the UV LED Module Replacement Schedule below.

REPLACING HEPA/CHARCOAL FILTER IN AIR 2.01. Shut off power to the Healthe Air 2.0 via the main wall switch.2. The HEPA filter is located behind the perforated screen door opposite of the

motion sensor. Remove the two screws (5/64 hex) securing the screen door and allow the door to swing down. (Fig 1)

3. Once the screen door is opened, bend the tabs on the side of the filter to release and remove it. (Fig 2)

4. Install new filter.5. Close the screen door and secure with the corresponding screws and turn on

the power via the main wall switch. (Fig 1)

UVC LED MODULE REPLACEMENT SCHEDULEThis recommended replacement schedule is based on a daily average hours of operation.

Hours of Daily Operation Replace the Modules Every

2 hours/day 48 months4 hours/day 24 months8 hours/day 12 months12 hours/day 8 months

REPLACING UVC LED MODULE IN AIR 2.01. Shut off power to the Healthe Air 2.0 via the main wall switch.2. Remove the two (5/64 hex) screws from each of the perforated screen

doors (2 screws each door, 4 total) and allow the doors to swing down. (Fig 3)

3. Once both doors are opened, remove the four screws securing the general illumination LED Module and allow it to swing down to expose the two (2) UVC LED Modules behind it. (Fig 4 and Fig 5)

4. Uninstall both UVC LED Modules by disconnecting the quick connectors and removing the six screws securing each of the UVC LED Modules. (Fig 5)

5. Install the new UVC LED Modules with the corresponding screws and attach the quick connectors to establish an electrical connection. (Fig 5)

6. Reinstall the general illumination LED Module back into the main housing using corresponding screws. (Fig 4)

7. Close and reinstall both perforated screen doors with the corresponding hex screws and turn on the power. (Fig 3)

Fig 1

Fig 2

Fig 3

Fig 4

Fig 5

©2020 Healthe Inc. All Rights Reserved. Specifications subject to change without notice.

DOC-00009-REV1

Healthe Inc.3905 W Eau Gallie Blvd, Suite 101, Melbourne, FL 32934877.999.5742 | healtheinc.com