HE-1500Di HE-7300Di Transducer Setup
-
Upload
manuel-diaz-gomez -
Category
Documents
-
view
218 -
download
4
description
Transcript of HE-1500Di HE-7300Di Transducer Setup
-
INSTRUCTION FOR TRANSDUCER SET-UP
HE-7300-Di HE-1500-Di
-
Transducer set-up for HE-7300-Di and HE-1500-Di Thank you for purchasing HONDEX products. This document explains the transducer setting for New VF Models : HE-7300-Di and HE-1500-Di. Please read this document carefully to set the transducer properly. 1-1. When you turn on the Power initially, the following window appears.
Press SET or > so that frequency set-up menu appears.
1-2. Select transducer from the list, then press MENU key.
When selecting OTHER TD, it is necessary to set-up the details of transducer manually on the following window.
1. Initial Setting of Transducer
-
1-3. Following display appears. Press MENU key to complete the set-up. You can also press SET key to return to the transducer list.
*Wrong set-up may damage on the product or transducer. 2-1. Indicate the transducer list. Go to MENU3 8 INITIALIZE 4 TRANSDUCER SET. 2-2. Select a transducer.
Transducer List Display
2. Set-up Transducer
-
It is necessary to select OTHER TD when using any transducer other than transducer list or 2 different transducers. 3-1. Indicate the transducer list. The value shown is the current set-up frequency. Go to MENU3 8 INITIALIZE 4 TRANSDUCER SET.
3-2. Select OTHER TD to show the display for detailed set-up of transducer.
3-3. Set-up each item on the display. Please refer to the followings for more explanation on the detailed set-up.
3. Set-up Other Transducer
This is the current frequency set-up value.
-
Type of Transducer Select the type of transducer. Single : Single frequency transducer Dual(3P): Dual frequencies by 1 transducer Dual(5P): Dual frequencies with 5P plug or 2 transducers. [Caution]
- Additional junction cable, BK01, is required when connecting 2 transducers. - The transducer connector needs to e 5P plug when connecting 2 transducers.
Refer to the following information about each detailed transducer set-up and pin assignment for each connector.
4. Detailed Set-up
-
FREQ. TX Set the transmitted frequency from transmitter. Selectable from 27~250kHz. NOMINAL FREQ. Set the frequency to be shown on the display. This value is indicated on the display. Selectable from 20~300kHz. TRANS TAP Optimize the matching of transmitter and transducers impedance. Select A when no selection is shown in Transducer List on the previous menu. When using 2 transducers, it is necessary to set manually. Refer to the attached Setting List for Standard Transducer and select the level for each. Initial set-up : A (Minimum Level)
Higher level set-up (B, C, D) may cause damage on transducer and main unit.
-
1st Edition JAN2012
5. Set-up Value for HONDEX Transducer