GS250K DIESEL GENSET MODEL GS250K - …cagenerators.com/assets/pdf/GS250K.pdf · specifications and...
Transcript of GS250K DIESEL GENSET MODEL GS250K - …cagenerators.com/assets/pdf/GS250K.pdf · specifications and...
specifications and design liable to modifications without prior notice
GS250K DIESEL GENSETMODEL GS250K
Stand-by Power @ 50Hz 220kW / 275 kVA Prime Power @ ¤Hz 200 kW / 250 kVA
Standard Features
General features :
Engine (VOLVO , TAD740GE )Charge alternator 24 V , Governor:Electronic typeECUAlternator (LEROY SOMER , LSA462L6 )Single bearing alternator IP 23 , insulation class H /HRadiator 50°C [122°F]°C max. T° air inlet with coolantcapSkid and vibration isolatorsDry type air filterMain line circuit breakerMicroprocessor control panel24 V battery, rack and cableIndustrial silencer (loose)User manual
Generator Ratings
Voltage HZ Phase P.F Standby Amps Standby RatingskW/kVA
Prime RatingskW/kVA
415/240 50 3 0.8 367 211 / 264 192 / 240400/230 50 3 0.8 397 220 / 275 200 / 250380/220 50 3 0.8 418 220 / 275 200 / 250240/120 50 3 0.8 635 211 / 264 192 / 240230/115 50 3 0.8 690 220 / 275 200 / 250220/110 50 3 0.8 722 220 / 275 200 / 250200/115 50 3 0.8 794 220 / 275 200 / 250
Stand-By ratings are available for the duration of any power outage. No overload capacity is specified at this ratings. Prime ratings are availableper BS 5514, DIN 6271, ISO-3046 and IEC 34-1 with 10% overload capacity one hour in twelve hours.
Conditions of sale
SDMO provides a full line of products with high qualityrecognized engines and alternators.Service and parts are available from SDMO distributors as asingle source of responsibility.
Each and every units is factory tested. All generator sets arealso prototype tested.Two years limited warranty , please refer to the conditionsterms . Five years extended are also available.
specifications and design liable to modifications without prior notice
ENGINE DATAManufacturer / Model
Cylinder ArrangementDisplacement
Bore and StrokeCompression ratio
Rated RPMPiston Speed
Max. stand by Power at rated RPMFrequency regulation, steady state
BMEPGovernor : type
VOLVO TAD740GE , 4-cycle, Turbo , Air/Air DC6 X L
7.28L [444.3C.I.]107mm [4.2in.] X 135mm [5.3in.]
17.2 : 11500 Rpm
6.75m/s [22.1ft./s]242kW [324BHP]
+/-0.5%25bar [362psi]
Electronic type ECUExhaust System
Exhaust gas flowExhaust temperature
Max back pressure
653L/s [1384cfm] 540°C [1004°F]
1000mm CE [39in. WG]Fuel System
110% (Stand By power )100% (of the Prime Power)
75% (of the Prime Power)50% (of the Prime Power)
Total fuel flow
55.5L/h [14.7gal/hr] 50.5L/h [13.3gal/hr]37.5L/h [9.9gal/hr]25.2L/h [6.7gal/hr]110L/h [29.1gal/hr]
Oil SystemTotal oil capacity w/filters
Oil Pressure low idleOil Pressure rated RPM
Oil consumption 100% loadOil capacity carter
29L [7.7gal] 0.7bar [10.1psi]5bar [72.5psi]
0.05L/h [0.0gal/hr]24L [6.3gal]
Thermal balance 100% loadHeat rejection to exhaustRadiated heat to ambiant
Heat rejection to coolant
160kW [9098Btu/mn]13kW [739Btu/mn]
99kW [5629Btu/mn] Air intake
Max. intake restrictionEngine air flow
500mm CE [20in. WG]245L/s [519cfm]
Coolant SystemRadiator & engine capacity
Max water temperatureOutlet water temperature
Fan powerFan air flow
Available restriction on air flowType of coolant
Thermostat
36.9L [9.7gal]103°C [217°F]93°C [199°F]
5 kW5.4m3/s [11443cfm]45mm CE [1.8in. WG]
Glycol-Ethylene75-88 °C
EmissionsHCCONox
PM
30 mg/Nm3330 mg/Nm32800 mg/Nm357.2 mg/Nm3
specifications and design liable to modifications without prior notice
ALTERNATOR SPECIFICATIONS
GENERAL DATACompliance with NEMA MG21, UTE NF C51.111, VDE 0530, BS4999, CSA standards.
Vacuum-impregnated windings with epoxy varnish.IP21 drip proof.
ALTERNATOR DATAManufacturer / Type
Number of phasePower factor (Cos Phi)
AltitudeOverspeed
Pole : numberExciter type
Insulation : class, temperature riseVoltage regulator
Sustained short circuit currentTotal harmonics (TGH/THC)
Wave form : NEMA = TIF – TGH/THCWave form : CEI = FHT – TGH/THC
Bearing : numberCoupling
Voltage regulation 0 to 100% loadRecovery time (20% Volt dip) ms
SkVA with 90 % of nominal sustained voltage (at 0.4 PF)
LEROY SOMER LSA462L6 3
0.8< 1000 m2250 rpm
4SHUNTH / HR448
3 IN = 10s< 4%< 50< 2%
1Direct
+/- 1%< 500 ms
670
OTHER ALTERNATOR DATAContinuous nominal rating @ 40°C
Standby rating @ 27°CEfficiencies @ 4/4 load
Air flowShort circuit ratio;50 (Kcc)
Direct axis synchro reactance unsaturated (Xd)Quadra axis synchro reactance unsaturated (Xq)
Open circuit time constant;50 (T’do)Direct axis transient reactance saturated (X’d)
Short circuit transient time constant (T’d)Direct axis subtransient reactance saturated (X’’d)
Subtransient time constant (T’’d)Quadra axis subtransient reactance saturated (X’’q)
Zero sequence reactance unsaturated (Xo)Negative sequence reactance saturated (X2)
Armature time constant (Ta)No load excitation current (io)
Full load excitation current (ic)Full load excitation voltage (uc)
Recovery time (Delta U = 20% transitoire)Motor start (Delta = 20% perm. Or 50% trans.)
Transient dip (4/4 charge) – PF : 1.8 ARNo load lossesHeat rejection
300 kVA337 kVA92.8 %
0.51m3/s [1080.62cfm]0.41
327 %196 %
2100 ms15.5 %105 ms9.3 %10 ms11.5 %0.5 %10.4 %16 ms1.1 A4 A35 V
< 500 ms700 kVA
16 %5.65 kW18.5 kW
specifications and design liable to modifications without prior notice
Control Panels
TELYS Specifications :Frequency meter, Ammeter, Voltmeter
Alarms and faults Oil pressure, water temperature, No start-up,Overspeed, Min/max alternator, Min/max battery voltage, Low fuel level,Emergency stop Engine parameters Hours counter, Oil pressure, Watertemperature, Engine speed, Battery voltage, Fuel level
KERYS Specifications :Frequency meter, Ammeter, Voltmeter
Alarms and faults Oil pressure, water temperature, No start-up,Overspeed, Min/max alternator, Min/max battery voltage, Low fuel level,Emergency stop Engine parameters Hours counter, Oil pressure, Watertemperature, Engine speed, Battery voltage, Fuel level Additionalspecifications Website, Troubleshooting, Assistance and Maintenance,Plotting and logging, Load impact, 8 configurations available,Compliance with international standards...
M80 Specifications : Tachometer, Emergency stop
button, client connection terminal strip, EC certified Engine parameters :Hours counter, Oil pressure gauge,Water temperature indicator, Oil pressure indicator
specifications and design liable to modifications without prior notice
Options
Engine and Radiator Alternator Control panel
Anti condensation heater NFPA 110 level 1Heat shield protection Enforced impregnation Paralleling systemOil drain extension Oversized alternator Remote annunciatorHeavy duty air filter Oil temperature shutdown
Lube oil drain pump Exhaust Key start panelRadiator core guard Residential silencer LiteratureBattery charger Critical silencer PartsBlock heater Flexible exhaust conn. Maintenance
Fuel Enclosure M227
Day tank Silent 69 db @ 23 Ft (stby)Subbase fuel tanks UL
Water separator fuel filter
Weight and Dimensions
Open Model
Overall size l x w x h :2900mm [114in] x 1300mm [51in] x 1690mm [67in]
Weight :2250kg [4959lbs] Net 2650kg [5841lbs] Brut
With Optional Enclosure
Overall size l x w x h :4004mm [158in] x 1380mm [54in] x 2125mm [84in]
Weight :3200kg [7053lbs] Net 3590kg [7912lbs] Brut