High-Speed Genset - tekhar.comtekhar.com/Programma/HYUNDAI/pdf_pict/Disel generators/DIGI.pdf ·...
Transcript of High-Speed Genset - tekhar.comtekhar.com/Programma/HYUNDAI/pdf_pict/Disel generators/DIGI.pdf ·...
▲ High-Speed Genset(Mounted Panel Type)
▲ High-Speed Genset(Radiator Type)
HHI, Hyundai Heavy Industries Co. Ltd., is one of the world’s leading
synchronous Diesel Generator Set manufacturers.
With proven performance, Hyundai’s Diesel Generator Set meets or exceeds
our customer’s need for service, safety and engineering.
With proven performance and extensive expertise, HHI diesel generator sets
offer excellent performance, versatility, reliability in extreme climate and
demanding applications worldwide.
Hyundai satisfies its customers by utilizing advanced technology, continuous
product improvement, and maintaining an uncompromising commitment to
innovation in order to give the customers the confidence to recommend
Hyundai Diesel Generators for any application.
▲ Medium-Speed Genset(Heat Exchanger Type)
Medium-& Low-Speed Gensets
Output 465~20,000 kW
Frequency 60 Hz or 50 Hz
Voltage 380 ~ 13,800 V
Revolution 1200 rpm or below
Cooling by Remote Radiator or Heat Exchanger
● Features of Diesel Generator Sets 4
● Mounted Control Panel 6
● Floor-Standing Control Panel 8
● Specifications (17~320 kW) 10
● Specifications (75~515 kW) 12
● Specifications (20~300 kW) 14
● Specifications (320~2000 kW) 16
● Specifications (280~2000 kW) 18
● Specifications (600~3420 kW) 20
● Specifications (1250~5320 kW) 22
C o n t e n t s
HYUNDAI DIESEL GENERATOR 02 03
High-Speed Gensets
Output 20~2,000 kW
Frequency 60 Hz or 50 Hz
Voltage 200 ~ 13,800 V
Revolution 1800 rpm or 1500 rpm
Cooling by Radiator or Heat Exchanger
Emergency Power
▶ for Intelligent Building
▶ for Broadcasting Facility
▶ for Apartment Housing
▶ for Hotel, Hospital, etc.
▶ for Special SCR Load, etc.
Continuous Power
▶ for Co-generation Power Station
▶ for Peak-Shaving in Summer and Winter
▶ for Temporary Power at a Construction Site
Various Diesel Engines
to supply various worldwide engine brands
according to customers request.
HMC, DAEWOO, VOLVO, JOHN DEERE,
CUMMINS, MTU, MITSUBIHI, PERKINS,
CATERPILLAR
Large Battery Charger
to check the charging voltage and increase
capacity to shorten charging time.
�20~300 kW: 5 A �above 320 kW: 10 A
Sound Attenuated Silencer
to use durable expanded silencer and internal
sound-attenuated material to enhance
attenuation efficiency and adiabatic rate of
silencer.
�Attenuation: 25dB (A)
Convenient Fuel Service Tank
to protect engine from rust with rustproof
paint on the interior surface of fuel tank and
attach level gauge on front surface of floor-
standing fuel tank to check fuel level.
Features of Diesel Generator Sets
▲ Mounted Large Fuel Tank
▲ Durable Jacket Water Heater
▲ Safe and Convenient Terminal Box
▲ Durable and Efficient Alternator
Durable and Efficient Alternator
to be manufactured per JEM 1354, IEC, and tested per
IEEE standards.
Reliable Circuit Breaker
to adopt reliable HHI breakers which have been certified
and approved by worldwide authorized agencies.
Safe and Convenient Terminal Box
to easily connect the terminal box with ample clearance
between main power cables so as to meet safety
standards.
Durable Jacket Water Heater
to improve the duality of JW heater by using high pressure
hose and connector in order to prevent water from
dripping out of a worn-out hose.
Air Cutting in Fuel Line
to keep air from going into the fuel return line with check
valve during any long term stop.
Strongly Built Common Bed
to reinforce bed above 250 mm in height taking vibration
and shipping into consideration.
Reliable Maintenance Tool
to supply “KS” marked tool for operation & maintenance.
HYUNDAI DIESEL GENERATOR 04 05
Mounted Control Panel
�Engine Control Unit (ECU)�Fault Indicators�Voltage/Ampere Switch (VS/AS)�Starting Switch�Voltage Adjusting Switch�Emergency Stop Button�Dimension W×H×D 500×330×300
�Running Hours Hr�Engine Speed rpm�Lube Oil Pressure kg/cm2
�Jacket Water Temperature ℃
�Voltmeter Vac�Ammeter A�Frequency Meter Hz�Battery Voltmeter Vdc
Starting Failure
Over Speed
High J.W. Temp.
Low L.O. Pressure
Emergency Stop
Over Voltage
Over Current
●
●
●
●
●
●
○
●
●
●
●
●
●
○
●
●
●
●
●
●
●
●
●
●
●
●
●
○
Protection Alarm Lamp Alarm horn CB Trip Engine Stop
Mounted Control Panel
Standard Protection Device
HYUNDAI DIESEL GENERATOR 06 07
Floor-Standing Control Panel
Starting Failure
Over Speed
High J.W Temp.
Low L.O. Pressure
Emergency Stop
Over Voltage
Under Voltage
Over Current
Low F.O. Level
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
○
●
●
●
●
●
●
○
○
○
Protection Alarm Lamp Alarm horn CB Trip Engine Stop
HYUNDAI DIESEL GENERATOR
�Wattmeter kW�Voltmeter Vac�Ammeter A�Frequency Meter Hz�Power Factor Meter PF�Battery Voltmeter Vdc�Battery Ammeter Adc�Electric Over Voltage Relay (EOVR)�Electric Over Current Relay (EOCR)�Electric Under Voltage Relay (EUVR)
�Engine Control Unit (ECU)�Battery Charger�Fault Indicator�Voltage / Ampere Switch (VS / AS)�Starting Switch�Voltage Adjusting Switch�Emergency Stop Button�Main Circuit Breaker (ACB or VCB)�Dimension (ACB) W×H×D (mm) 800×2000×1060�Dimension (VCB) W×H×D (mm) 800×2350×2260
Standard Protection Device
Generator Control Panel
08 09
Specifications 17 kW~320 kW (1800/1500 rpm)
NOTE) 1. A genset model is based on standby output rating of alternator.
� Standby: power rating at below average 90% load for 1 hour in any 1-hour period.
No application with overload (DIN6270B)
� Prime : max. power rating at variable load for unlimited periods with overload
available for 1 hour in any 12-hour period. (DIN6270B)
Specifications
Brushless self-exiting
380/220V (220/127V,440/254V,480/277V,3300V,6600V,11000V,13800V)
60/50Hz, 4P
3-phase 4-wire / P.F 0.8
F ( H ) / IP-20 ( IP -22, IP-23)
Semi-Auto Control
IP-40
MCCB 4P
Voltmeter, Ammeter, Frequency Meter, Phase Selection Switch, Buzzer, Engine Selection Switch
Auto Control
IP-40
4-cycle, water cooled
Mechanical
ASTM D9775 No1D/2D or KS M 2610 No. 2 Diesel Fuel Oil
API CD or CF (SAE 15W/40)
Water cooled by radiator
1800/1500rpm
Electric cell motor
GENSET Model60Hz50Hz
OUTPUT (kW)
Dimension (mm)
Weight (kg)
Exhaust Pipe Size (mm)
Radiator Size W×H (mm)
Ventilation Flow Rate (m2/min)
Output (PS)Standby
Prime
Control
Protection
Circuit Breaker
Meters
Control
Protection
Circuit Breaker
Meters
Maker
Model
Type
No of Cylinders
Bore×Stroke (mm)
Cylinder Displacement (ℓ)
Governor Type
Recommended Fuel Oil
Fuel Consumption (ℓ/hr)
Recommended Lub. Oil
Lub. Oil Capacity (ℓ)
Cooling System
Coolant Capacity (ℓ)
Starting System
Type
Voltage Rating
Frequency/Pole
Phase-Wire/Power Factor
Insulation/Protection Class
Mounted
Floor Standing
HEG115HS97HE
HEG80HS67HE
HEG55HS36HE
HEG37HS30HE
HEG17HS12HE
GENSET
Standby
Prime
rpm / Hz
Length
Width
Height
Engine
Alternator
Panel
17/12
15/11
1600
570
1100
845
50A
610×540
71.7
HMC
D4BB-G
28/23
25/21
91.9×100
2.607
3.2/1.8
5.4
15
37/30
33/26
2000
740
1202
958
50A
610×540
81.9
HMC
D4AF-G
60/50
54/45
104×105
3.568
10.7/7.0
8.5
20
55/36
50/32
2000
740
1202
968
65A
610×540
83.4
HMC
D4AK-G
82/60
74/54
100×105
3.298
15/8.7
8.5
20
115/97
105/87
2500
770
1193
1410
65A
706×670
93.1
HMC
D6BT-G
180/155
162/140
118×115
7.54
29.8/22.7
13
25
80/67
73/60
2200
780
1219
1400
65A
706×670
91.1
HMC
D6BR-G
130/110
117/99
118×115
7.54
20.7/15.6
13
25
I-6I-6I-4I-4I-4
Wattmeter, Voltmeter, Ammeter, Frequency, Power Factor, Battery Voltage/Ammeter,
MCCB 4P ACB 4P
10 11
2. Operating Conditions
� Ambient temperature: -15℃~40℃
� Standard altitude: below 1000 m sea level
� Relative humidity: below 85%
� Installation area: indoor (temp. 5℃~40℃)
HEG125HS105HE
HEG175HS132HE
HEG200HS172HE
HEG230HS200HE
HEG250HS
-
HEG275HS230HE
HEG300HS260HE
HEG320HS
-
125/105
114/95
2500
860
1405
1935
65A
742×830
130
HMC
D6AU-G
190/170
171/153
134×140
11.14
32.8/25
24
37
Brushless self-exiting
380/220V (220/127V,440/254V,480/277V,3300V,6600V,11000V,13800V)
60/50Hz, 4P
3-phase 4-wire / P.F 0.8
F ( H ) / IP-20 ( IP -22, IP-23)
Semi-Auto Control
IP-40
MCCB 4P
Voltmeter, Ammeter, Frequency Meter, Phase Selection Switch, Buzzer, Engine Selection Switch
Auto Control
IP-40
ACB 4P
API CD or CF (SAE 15W/40)
175/132
159/118
2500
880
1460
2072
90A
742×830
285
HMC
D6AZ-G2
300/210
270/189
134×140
11.14
43.3/32
24
37
200/172
182/154
2500
880
1460
2275
90A
742×830
285
HMC
D6AZ-G1
300/270
270/243
134×140
11.14
49.5/38
24
37
230/200
210/184
2600
1080
1430
2617
90A
790×860
294.2
HMC
D6AC-G
350/320
315/288
130 ×140
11.14
56/45
24
40
250/-
228/-
2700
1300
1500
2850
100A
838×1000
504.3
HMC
D6CA-G3
410/-
400/-
133×155
12.92
61/-
28
61
275/230
250/200
2700
1300
1500
2850
100A
838×1000
504.3
HMC
D6CA-G3
410/360
400/320
133×155
12.92
67/-
28
61
300/260
273/230
2700
1300
1500
2850
100A
838×1000
504.3
HMC
D6CA-G2
450/400
430/360
133×155
12.92
72/56
28
61
320/-
280/-
2700
1300
1500
2850
100A
838×1000
520
HMC
D6CA-G1
490/-
440/-
133×155
12.92
77/-
28
61
4-cycle, water cooled
Mechanical Electronic
ASTM D9775 No1D/2D or KS M 2610 No. 2 Diesel Fuel Oil
Water cooled by radiator
1800/1500rpm
Phase Selection Switch, Engine Operating Switch, CB Selection Switch, Voltage Adjusting Switch, EOVR, EOCR, EUVR, Buzzer, Lamp, Push-button
Electric cell motor
I-6 I-6 I-6 I-6 I-6 I-6 I-6 I-6
API CD or CF (SAE 15W/40)
4-cycle, water cooled, turbocharged
ASTM D975 No1D/2D or KS M 2610 No. 2 Diesel Fuel Oil
Water cooled by radiator
1800/1500 rpm
Brushless self-exiting
380/220V (220/127V,440/254V,480/277V,3300V,6600V,11000V,13800V)
60/50 Hz, 4P
3PH- 4W / P.F 0.8
H / IP-22 (IP-23)
Semi-Auto Control
IP-40
MCCB 4P
Voltmeter, Ammeter, Frequency Meter, Phase Selection Switch, Buzzer, Engine Selection Switch
Auto Control
IP-40
ACB 4P
Wattmeter, Voltmeter, Ammeter, Frequency, Power Factor, Battery Voltage/Ammeter,
Electric motor
GENSET Model60Hz50Hz
OUTPUT (kW)
Dimension (mm)
Weight (kg)
Exhaust Pipe Size (mm)
Radiator Size W×H (mm)
Ventilation Flow Rate (m2/min)
Output (HP)Standby
Prime
Control
Protection
Circuit Breaker
Meters
Control
Protection
Circuit Breaker
Meters
Maker
Model
Type
No of Cylinders
Bore×Stroke (mm)
Cylinder Displacement (ℓ)
Governor Type
Recommended Fuel Oil
Fuel Consumption (ℓ/hr)
Recommended Lub. Oil
Lub. Oil Capacity (ℓ)
Cooling System
Coolant Capacity (ℓ)
Starting System
Type
Voltage Rating
Frequency, Pole
Phase-Wire/Power Factor
Insulation/Protection Class
Mounted
Floor Standing
HEG175VS160VE
HEG140VS130VE
HEG115VS110VE
HEG90VS85VE
HEG75VS70VE
GENSET
Standby
Prime
rpm / Hz
Length
Width
Height
Engine
Alternator
Panel
75/70
68/65
1979
664
1230
1050
80A
450×523
114
VOLVO
TD520GE
121/116
111/105
108×130
4.76
19.1/18.6
11
22
90/85
82/79
2189
732
1230
1250
80A
440×609
115.5
VOLVO
TAD520GE
150/139
137/128
108×130
4.76
21.8/20.8
11
19.7
115/110
105/100
2157
741
1300
1400
80A
667×631
148
VOLVO
TD720GE
182/174
167/159
108×130
7.15
29/27.6
17
22
175/160
150/140
2302
1001
1514
1688
100A
941×951
194.5
VOLVO
TWD710G
271/246
230/218
104.77×130
6.73
43.5/39.2
24
26
140/130
125/120
2325
866
1300
1500
80A
660×701
200
VOLVO
TAD720GE
222/208
203/190
108×130
7.15
33.6/30.5
17
23.8
Mechanical
I-6I-6I-6I-4I-4
Specifications 75 kW~515 kW (1800/1500 rpm)
Specifications
NOTE) 1. A genset model is based on standby output rating of alternator.
� Standby: power rating at below average 90% load for 1 hour in any 1-hour period.
No application with overload (DIN6270B)
� Prime : max. power rating at variable load for unlimited periods with overload
available for 1 hour in any 12-hour period. (DIN6270B)
HEG200VS180VE
HEG225VS220VE
HEG250VS240VE
HEG260VS
-
HEG300VS285VE
HEG350VS330VE
HEG400VS360VE
HEG450VS410VE
HEG515VS450VE
200/180
185/160
2354
877
1491
1738
100A
785×1001
173.5
VOLVO
TWD740GE
321/277
292/253
107×135
7.28
50.5/43.5
24
26
API CD or CF (SAE 15W/40)
225/220
205/200
2458
945
1491
1806
100A
795×1001
193
VOLVO
TAD740GE
352/336
321/306
107×135
7.28
53.8/52.6
24
36.9
250/240
210/205
2657
945
1636
1985
100A
951×1140
223
VOLVO
TAD1030GE
393/367
329/311
120.65×140
9.6
64.6/60.6
32
37
260/ -
230/ -
2707
945
1636
2035
100A
951×1140
210
VOLVO
TAD1031GE
400/ -
366/ -
120.65×140
9.6
71.1/ -
32
37
300/285
275/260
2948
1120
1587
2470
125A
910×890
296
VOLVO
TAD1240GE
469/435
428/397
131×150
12.13
74.7/67.5
31
44
350/330
320/300
2948
1120
1587
2635
125A
910×890
296
VOLVO
TAD1241GE
534/494
488/452
131×150
12.13
84.1/78.2
31
44
400/360
365/330
2948
1120
1587
2690
125A
910×890
385
VOLVO
TAD1242GE
611/541
558/494
131×150
12.13
101.6/85.3
31
44
450/410
410/375
3264
1089
1765
2992
150A
951.4×1140
534
VOLVO
TAD1630GE
672/608
612/554
144×165
16.12
118.5/105.4
57
60
515/450
465/410
3344
1261
1765
3091
150A
1123×1132
450
VOLVO
TAD1631GE
768/660
687/601
144×165
16.12
132.3/114.1
57
64
4-cycle, water cooled, turbocharged
Electronic
ASTM D975 No1D/2D or KS M 2610 No. 2 Diesel Fuel Oil
Water cooled by radiator
1800/1500 rpm
Brushless self-exiting
380/220V (220/127V,440/254V,480/277V,3300V,6600V,11000V,13800V)
60/50 Hz, 4P
3PH- 4W / P.F 0.8
H / IP-22 (IP-23)
Semi-Auto Control
IP-40
MCCB 4P
Voltmeter, Ammeter, Frequency Meter, Phase Selection Switch, Buzzer, Engine Selection Switch
Auto Control
IP-40
ACB 4P
Phase Selection Switch, Engine Operating Switch, CB Selection Switch, Voltage Adjusting Switch, EOVR, EOCR, EUVR, Buzzer, Lamp, Push-button
Electric motor
I-6 I-6 I-6 I-6 I-6 I-6 I-6 I-6 I-6
2. Operating Conditions
� Ambient temperature: -15℃~40℃
� Standard altitude: below 1000 m sea level
� Relative humidity: below 85%
� Installation area: indoor (temp. 5℃~40℃)
12 13
GENSET Model60Hz50Hz
OUTPUT (kW)
Dimension (mm)
Weight (kg)
Exhaust Pipe Size (mm)
Radiator Size W×H (mm)
Ventilation Flow Rate (m2/min)
Output (PS)Standby
Prime
Control
Protection
Circuit Breaker
Meters
Control
Protection
Circuit Breaker
Meters
Maker
Model
Type
No of Cylinders
Bore×Stroke (mm)
Cylinder Displacement (ℓ)
Governor Type
Recommended Fuel Oil
Fuel Consumption (ℓ/hr)
Recommended Lub. Oil
Lub. Oil Capacity (ℓ)
Cooling System
Coolant Capacity (ℓ)
Starting System
Type
Voltage Rating
Frequency, Pole
Phase-Wire/Power Factor
Insulation/Protection Class
Mounted
Floor Standing
HEG20DS15DE
HEG28DS23DE
HEG50DS40DE
HEG60DS50DE
GENSET
Standby
Prime
rpm / Hz
Length
Width
Height
Engine
Alternator
Panel
20/15
17/13
1990
770
1460
650
65A
685×480
93.5
DAEWOO
DC24
34/28
31/25
91.9×100
2.607
8.2/6.2
5.4
22.2
28/23
25/20
2140
770
1460
850
65A
685×480
113.8
DAEWOO
DB33
47/39
43/25
102×100
3.268
9.2/7.8
7.5
25
50/40
45/34
2260
750
1460
1063
65A
660×720
173.8
DAEWOO
D034TI
82/65
75/57
102×100
3.268
15.6/12.5
6.5
21.5
60/50
50/44
2597
870
1460
1300
65A
760×590
225.8
DAEWOO
DB58
95/80
87/73
102×118
5.785
18.1/15.3
19
34
Brushless self-exiting
380/220V (220/127V,440/254V,480/277V,3300V,6600V,11000V,13800V)
60/50 Hz, 4P
3-phase 4-wire / P.F 0.8
F ( H ) / IP-20
Semi-Auto Control
IP-40
MCCB 4P
Voltmeter, Ammeter, Frequency Meter, Phase Selection Switch, Buzzer, Engine Selection Switch
Auto Control
IP-40
MCCB 4P
Wattmeter, Voltmeter, Ammeter, Frequency, Power Factor,
API CD or CF (SAE 15W/40)
4-cycle, water cooled
Mechanical
ASTM D975 No1D/2D or KS M 2610 No. 2 Diesel Fuel Oil
Water cooled by radiator
1800 /1500 rpm
Electric cell motor
I-6I-4I-4I-4
Specifications 20 kW~300 kW (1800/1500 rpm)
Specifications
NOTE) 1. A genset model is based on standby output rating of alternator.
� Standby: power rating at below average 90% load for 1 hour in any 1-hour period.
No application with overload (DIN6270B)
� Prime : max. power rating at variable load for unlimited periods with overload
available for 1 hour in any 12-hour period. (DIN6270B)
HEG85DS70DE
HEG125DS100DE
HEG165DS140DE
HEG200DS170DE
HEG250DS220DE
HEG275DS240DE
HEG300DS
-
85/70
75/62
2755
870
1460
1800
65A
750×830
288.3
DAEWOO
D1146
143/116
130/105
111×139
8.071
26.6/20.8
15.5
38.5
Brushless self-exiting
380/220V (220/127V,440/254V,480/277V,3300V,6600V,11000V,13800V)
60/50 Hz, 4P
3-phase 4-wire / P.F 0.8
F ( H ) / IP-20
Semi-Auto Control
IP-40
MCCB 4P
Voltmeter, Ammeter, Frequency Meter, Phase Selection Switch, Buzzer, Engine Selection Switch
Auto Control
IP-40
ACB 4P
API CD or CF (SAE 15W/40)
125/100
105/90
2755
870
1460
1900
100A
750×830
358.1
DAEWOO
D1146T
200/160
170/145
111×139
8.071
35.1/27
15.5
38.5
165/140
145/125
2959
946
1619
2046
100A
910×1000
454.2
DAEWOO
P086TI-1
270/226
245/205
111×139
8.071
47.1/39.5
15.5
48.5
200/170
175/150
2959
946
1619
2246
100A
910×1000
534.1
DAEWOO
P086TI
303/270
279/240
111×139
8.071
56.8/48.4
15.5
48.5
250/220
220/195
3215
1015
1559
2639
100A
995×1080
679.9
DAEWOO
P126TI-3
375/343
343/304
123×155
11.051
76.5/66.2
23
60
275/240
240/210
3215
1015
1559
2639
100A
995×1080
722.4
DAEWOO
P126TI
450/370
378/328
123×155
11.051
76.5/66.2
23
60
300/ -
270/ -
3215
1015
1559
2639
100A
990×1080
722.4
DAEWOO
P126TI-2
465/ -
422/ -
123×155
11.051
82.5/ -
23
60
4-cycle, water cooled
Mechanical Electric
ASTM D975 No1D/2D or KS M 2610 No. 2 Diesel Fuel Oil
Water cooled by radiator
1800 /1500 rpm
Battery Voltage/Ammeter, Phase Selection Switch, Engine Operating Switch, CB Selection Switch, Voltage Adjusting Switch, EOVR, EOCR, EUVR, Buzzer, Lamp, Push-button
Electric cell motor
I-6 I-6 I-6 I-6 I-6 I-6 I-6
2. Operating Conditions
� Ambient temperature: -15℃~40℃
� Standard altitude: below 1000 m sea level
� Relative humidity: below 85%
� Installation area: indoor (temp. 5℃~40℃)
14 15
GENSET
GENSET
OUTPUT
(kW)
Standby
Prime
rpm / Hz
Model60Hz50Hz
360/320
325/285
2990
1397
1875
2650
150A
1146×1236
673.1
DAEWOO
P158LE-1
546/492
498/444
128×142
14.618
103/86.1
28
88
400/370
360/320
2990
1397
1875
2650
150A
1146×1236
673.1
DAEWOO
P158LE
602/563
547/494
128×142
14.618
115.7/102.9
28
88
450/395
405/360
3170
1388
1875
3000
150A
1146×1236
680.9
DAEWOO
P180LE-1
677/601
617/548
128×142
18.273
124.7/110
35
94
500/445
450/400
3170
1388
1875
3050
150A
1146×1236
680.9
DAEWOO
P180LE
734/674
676/602
128×142
18.273
144.6/128.7
35
94
560/500
510/460
3390
1388
1875
3800
150A
1300×1250
688.7
DAEWOO
P222LE-1
850/752
765/696
128×142
21.927
173.5/154.3
40
113
Length
Width
Height
Control
Protection
Circuit Breaker
Meters
Control
Protection
Circuit Breaker
Meters
Dimension
(mm)
Weight (kg)
Exhaust Pipe Size (mm)
Radiator Size W×H (mm)
Ventilation Flow Rate (m2/min)
Maker
Model
Type
No of Cylinders
Bore×Stroke (mm)
Cylinder Displacement (ℓ)
Governor Type
Recommended Fuel Oil
Fuel Consumption (ℓ/hr)
Recommended Lub. Oil
Lub. Oil Capacity (ℓ)
Cooling System
Coolant Capacity (ℓ)
Starting System
Type
Voltage Rating
Frequency, Pole
Phase-Wire/Power Factor
Insulation/Protection Class
Mounted
Floor
Standing
Engine
Alternator
Panel
320/280
290/255
2990
1397
1875
2540
150A
1146×1236
673.1
DAEWOO
P158LE-2
491/437
447/399
128×142
14.618
91.3/75.9
28
88
1800rpm / 1500rpm
4-cycle, water cooled, turbocharged
Electric
ASTM D975 No1D/2D or KS M 2610 No. 2 Diesel Fuel Oil
API CD or CF (SAE 15W/40)
Water cooled by radiator
Electric cell motor
Semi-Auto Control
IP-40
MCCB 4P
Voltmeter, Ammeter, Frequency Meter, Phase Selection Switch, Buzzer, Engine Selection Switch
Brushless self-exiting
380/220V (220/127V,440/254V,480/277V,3300V,6600V,11000V,13800V)
60/50 Hz, 4P
3PH-4W / P.F 0.8
F ( H ) / IP-20 ( IP -22, IP-23)
Auto Control
IP-40
ACB 4P
-
-
-
V-8 V-8 V-8 V-10 V-10 V-12
Output (PS)Standby
Prime
HEG320DS280DE
HEG360DS320DE
HEG400DS370DE
HEG450DS395DE
HEG500DS445DE
HEG560DS500DE
Wattmeter, Voltmeter, Ammeter, Frequency, Power Factor, Battery Voltage/Ammeter,
Specifications 320 kW~2000 kW (1800/1500 rpm)
Specifications
NOTE) 1. A genset model is based on standby output rating of alternator.
� Standby: power rating at below average 90% load for 1 hour in any 1-hour period.
No application with overload (DIN6270B)
� Prime : max. power rating at variable load for unlimited periods with overload
available for 1 hour in any 12-hour period. (DIN6270B)
650/580
585/523
3300
1435
2125
4300
200A
1347×1330
850
MAN
D2842LE203
976/860
927/798
128×142
21.93
160/139
32
108
750/620
625/570
3800
1580
2160
6720
250A
1422×1334
954
MTU
12V2000G82/62
1135/924
944/849
130×150
23.88
180/142.4
82
180
900/730
- /655
4200
1752
2217
7050
300A
1702×1575
1098
MTU
16V2000G42/22
1359/1094
- /978
130×150
31.84
210/164.4
110
220
1000/800
850/730
4200
1752
2217
7300
300A
1702×1575
1308
MTU
16V2000G82/62
1515/1216
1257/1094
130×150
31.84
238/180.7
110
220
1350/1200
- /1100
5400
2083
2955
9430
350A
1903×2019
1675
MTU
12V4000G40/20
2024/1807
- /1637
165×190
48.7
308/272.5
260
580
1500/1320
1350/1225
5400
2413
3100
9690
350A
2233×2161
1883
MTU
12V4000G80/60
2228/1990
2024/1807
165×190
48.7
346/302.8
260
660
1800/1600
- /1470
6430
2590
3260
12190
400A
2410×2318
2198
MTU
16V4000G40/20
2704/2391
- /2174
165×190
65
411/359.5
290
715
2000/1800
1800/1625
6430
2838
3530
12890
400A
2648×2588
2207
MTU
16V4000G80/60
2976/3027
2704/2750
165×190
65
462/408.7
290
835
600/520
535/480
3390
1388
1875
3800
150A
1300×1250
688.7
DAEWOO
P222LE
883/781
803/723
128 ×142
21.927
173.5/154.3
40
113
4-cycle, water cooled, turbocharged
Electric
ASTM D975 No1D/2D or KS M 2610 No. 2 Diesel Fuel Oil
API CD or CF (SAE 15W/40)
Water cooled by radiator
Electric cell motor
Brushless self-exiting
380/220V (220/127V,440/254V,480/277V,3300V,6600V,11000V,13800V)
60/50 Hz, 4P
3PH-4W / P.F 0.8
F ( H ) / IP-20 ( IP -22, IP-23)
-
-
-
-
Auto Control
IP-40
ACB 4P
1800rpm / 1500rpm
V-12 V-12 V-12 V-16 V-16 V-12 V-12 V-16 V-16
HEG600DS520DE
HEG650MS580ME
HEG750TS620TE
HEG900TS730TE
HEG1000TS800TE
HEG1350TS1200TE
HEG1500TS1320E
HEG1850TS1600TE
HEG2000TS1800TE
Phase Selection Switch, Engine Operating Switch, CB Selection Switch, Voltage Adjusting Switch, EOVR, EOCR, EUVR, Buzzer, Lamp, Push-button
2. Operating Conditions
� Ambient temperature: -15℃~40℃
� Standard altitude: below 1000 m sea level
� Relative humidity: below 85%
� Installation area: indoor (temp. 5℃~40℃)
16 17
GENSET
GENSET
OUTPUT
(kW)
Standby
Prime
rpm / Hz
Model60Hz50Hz
300/290
275/250
3286
990
1777
3275
150A
920×940
519
CUMMINS
NTA855-G2
465/430
420/380
140×152
14
89/78
38.6
79.8
350/ -
315/ -
3304
990
1777
3390
150A
920×940
521
CUMMINS
NTA855-G3
535/ -
480/ -
140×152
14
96/ -
38.6
84.8
400/330
345/300
3490
1266
1906
4410
150A
1175×1143
808.3
CUMMINS
KTA19-G2
600/495
525/450
159×159
18.9
113/91
45
91
450/400
410/365
3490
1266
1906
4410
150A
1175×1143
808.8
CUMMINS
KTA19-G3
685/600
620/540
159×159
18.9
122/107
45
91
500/460
455/405
3490
1266
1906
4565
150A
1175×1143
813
CUMMINS
KTA19-G4
755/675
680/600
159×159
18.9
133/121
45
91
Length
Width
Height
Control
Protection
Circuit Breaker
Meters
Control
Protection
Circuit Breaker
Meters
Dimension
(mm)
Weight (kg)
Exhaust Pipe Size (mm)
Radiator Size W×H (mm)
Ventilation Flow Rate (m2/min)
Maker
Model
Type
No of Cylinders
Bore×Stroke (mm)
Cylinder Displacement (ℓ)
Governor Type
Recommended Fuel Oil
Fuel Consumption (ℓ/hr)
Recommended Lub. Oil
Lub. Oil Capacity (ℓ)
Cooling System
Coolant Capacity (ℓ)
Starting System
Type
Voltage Rating
Frequency, Pole
Phase-Wire/Power Factor
Insulation/Protection Class
Mounted
Floor
Standing
Engine
Alternator
Panel
280/270
250/245
3286
990
1777
3150
150A
920×940
581.8
CUMMINS
NT855-G6
435/415
395/375
140×152
14
82/76
38.6
63.9
1800rpm / 1500rpm
4-cycle, water cooled, turbocharged
Electric
ASTM D975 No1D/2D or KS M 2610 No. 2 Diesel Fuel Oil
API CD or CF (SAE 15W/40)
Water cooled by radiator
Electric cell motor
Semi-Auto Control
IP-40
MCCB 4P
Voltmeter, Ammeter, Frequency Meter, Phase Selection Switch, Buzzer, Engine Selection Switch
Brushless self-exiting
380/220V (220/127V,440/254V,480/277V,3300V,6600V,11000V,13800V)
60/50 Hz, 4P
3PH-4W / P.F 0.8
F ( H ) / IP-20 ( IP -22, IP-23)
Auto Control
IP-40
ACB 4P
I-6 I-6 I-6 I-6 I-6 I-6
Output (HP)Standby
Prime
HEG280CS270CE
HEG300CS290CE
HEG350CS
-
HEG400CS330CE
HEG450CS400CE
HEG500CS460CE
Wattmeter, Voltmeter, Ammeter, Frequency, Power Factor, Battery Voltage/Ammeter,
Specifications 280 kW~2000 kW (1800/1500 rpm)
Specifications
NOTE) 1. A genset model is based on standby output rating of alternator.
� Standby: power rating at below average 90% load for 1 hour in any 1-hour period.
No application with overload (DIN6270B)
� Prime : max. power rating at variable load for unlimited periods with overload
available for 1 hour in any 12-hour period. (DIN6270B)
760/640
690/580
4297
1442
2092
7000
250A
1378×1334
1207
CUMMINS
QST30-G1
1135/940
1030/850
140 ×165
30.48
207/169
132
201
810/700
730/640
4297
1442
2092
7150
250A
1378×1334
1210
CUMMINS
QST30-G2
1200/1030
1085/935
140 ×165
30.48
219/187
132
201
875/780
790/700
4391
1442
2092
7450
250A
1378×1334
1385
CUMMINS
QST30-G3
1350/1200
1220/1080
140 ×165
30.48
228/204
132
201
1000/890
910/805
4470
1506
2092
8600
250A
1378×1334
1608
CUMMINS
QST30-G4
1490/1300
1350/1180
140 ×165
30.48
267/224
132
307
1250/1100
1090/890
5290
1785
2238
10300
250A
1900×1946
1710
CUMMINS
KTA50-G3
1850/1645
1635/1470
159 ×159
50.3
318/182
177
351
1520/1280
1260/1080
5886
2033
2756
12100
250A
1900×1946
1820
CUMMINS
KTA50-G9
2220/1880
1855/1585
159 ×159
50.3
375/321
204
386
1750/ -
1590/ -
6251
2789
3175
16300
300A
2600×2600
2020
CUMMINS
QSK60-G5
2547/ -
2312/ -
159 ×190
60.2
402/358
296
378.5
2000/ -
1800/ -
6251
2789
3175
16300
300A
2600×2600
2041
CUMMINS
QSK60-G6
2922/ -
2614/ -
159 ×190
60.2
466/393
296
378.5
600/565
545/510
4047
1423
1987
6040
200A
1347×1333
1157
CUMMINS
VTA28-G5
900/825
815/750
140 ×152
28
173/154
83
167
4-cycle, water cooled, turbocharged
Electric
ASTM D975 No1D/2D or KS M 2610 No. 2 Diesel Fuel Oil
API CD or CF (SAE 15W/40)
Water cooled by radiator
Electric cell motor
Brushless self-exiting
380/220V (220/127V,440/254V,480/277V,3300V,6600V,11000V,13800V)
60/50 Hz, 4P
3PH-4W / P.F 0.8
F ( H ) / IP-20 ( IP -22, IP-23)
-
-
-
-
Auto Control
IP-40
ACB 4P
1800rpm / 1500rpm
V-12 V-12 V-12 V-12 V-12 V-16 V-16 V-16 V-16
HEG600CS565CE
HEG760CS640CE
HEG810CS700CE
HEG875CS780CE
HEG1000CS890CE
HEG1250CS1100CE
HEG1520CS1280CE
HEG1750CS
-
HEG2000CS
-
Phase Selection Switch, Engine Operating Switch, CB Selection Switch, Voltage Adjusting Switch, EOVR, EOCR, EUVR, Buzzer, Lamp, Push-button
2. Operating Conditions
� Ambient temperature: -15℃~40℃
� Standard altitude: below 1000 m sea level
� Relative humidity: below 85%
� Installation area: indoor (temp. 5℃~40℃)
18 19
GENSET Model60Hz50Hz
OUTPUT (kW)
Dimension (mm)
Weight (kg)
Exhaust Pipe Size (mm)
Radiator Size W×H (mm)
Ventilation Flow Rate (m2/min)
Output (HP)Standby
Prime
Maker
Model
Type
No of Cylinders
Bore×Stroke (mm)
Cylinder Displacement (ℓ)
Governor Type
Recommended Fuel Oil
Fuel Consumption (ℓ/hr)
Recommended Lub. Oil
Lub. Oil Capacity (ℓ)
Cooling System
Coolant Capacity (ℓ)
Starting System
Type
Voltage Rating
Frequency, Pole
Phase-Wire/Power Factor
Insulation/Protection Class
Type
Control
Protection
Circuit Breaker
Meters
HEG1350IS1220IE
HEG1250IS1130IE
HEG1000IS840IE
HEG800IS680IE
HEG600IS515IE
GENSET
Standby
Prime
rpm / Hz
Length
Width
Height
Engine
Alternator
Panel
1350/1220
1225/1100
4935
2225
2892
10830
300A
1740×2000
1800
MHI
S12R-PTA2
1903/1723
1729/1562
170 ×180
49.03
331/296
180
305
1250/1130
1100/1025
4700
2225
2370
10830
300A
1740×1700
1800
MHI
S12R-PTA
1791/1595
1528/1448
170×180
49.03
287/265
180
335
1000/840
925/800
4232
1756
2453
7850
200A
1530×1630
1800
MHI
S12H-PTA
1448/1314
1314/1193
150×175
37.11
245/220
200
244
800/680
685/614
4015
1720
2020
6420
200A
1520×1300
1380
MHI
S12A2-PTA
1146/970
980/880
150×160
33.93
194/169
120
215
600/515
535/465
3790
1594
1963
5350
200A
1330×1000
720
MHI
S6R-PTA
865/744
771/670
170×180
24.51
145/124
94
113
Brushless self-exiting
380/220V (220/127V,440/254V,480/277V,3300V,6600V,11000V,13800V)
60/50 Hz, 4P
3PH-4W / P.F 0.8
F ( H ) / IP-20 ( IP -22, IP-23)
Free standing
Auto Control
IP-40
ACB 4P, VCB 4P
API CD or CF (SAE 15W/40)
4-cycle, water cooled, turbocharged
Electric
ASTM D9775 No1D/2D or KS M 2610 No. 2 Diesel Fuel Oil
Water cooled by radiator
1800/1500rpm
Wattmeter, Voltmeter, Ammeter, Frequency, Power Factor, Battery Voltage/Ammter,
Electric cell motor
V-12V-12V-12V-12I-6
Specifications 600 kW~3420 kW (1800/1500 rpm, 1200/1000 rpm)
Specifications
NOTE) 1. A genset model is based on standby output rating of alternator.
� Standby: power rating at below average 90% load for 1 hour in any 1-hour period.
No application with overload (DIN6270B)
� Prime : max. power rating at variable load for unlimited periods with overload
available for 1 hour in any 12-hour period. (DIN6270B)
HEG1500IS1320IE
HEG1600IS1510IE
HEG1800IS1680IE
HEG2000IS1800IE
HEG1280IM1200IN
HEG1700IM1600IN
HEG2600IM2400IN
HEG3420IM3200IN
1500/1320
1375/1200
5080
2230
2892
13000
300A
1740×2000
1800
MHI
S12R-PTAA2
2139/1882
1940/1712
170×180
49.03
358/314
180
350
Brushless self-exiting
380/220V (220/127V,440/254V,480/277V,3300V,6600V,11000V,13800V)
60/50 Hz, 4P
3PH-4W / P.F 0.8
F ( H ) / IP-20 ( IP -22, IP-23)
Free standing
Auto Control
IP-40
ACB 4P, VCB 4P
API CD or CF (SAE 15W/40)
1600/1510
1460/1375
5550
2732
3001
13300
350A
1740×2000
1950
MHI
S16R-PTA
2279/2131
2064/1944
170×180
65.37
393/354
230
350
1800/1680
1635/1520
5650
2732
3001
13800
350A
2410×2350
2040
MHI
S16R-PTA2
2547/2359
2312/2145
170×180
65.37
443/406
230
445
2000/1800
1800/1600
6000
2432
3456
16000
350A
2050×2500
2500
MHI
S16R-PTAA2
2822/2540
2540/2257
170×180
65.37
478/411
230
560
1280/1200
1224/1152
5500
2000
2500
14000
MHI
S6U-PTA
1812/1688
1727/1627
240×260
70.6
324/294
370
270
1700/1600
1638/1520
6400
2000
2600
19000
MHI
S8U-PTA
2416/2250
2302/2170
240×260
94.1
433/392
490
360
2600/2400
2448/2308
6200
2500
3000
25000
MHI
S12U-PTA
3623/3375
3453/3256
240×260
141.2
649/589
520
520
3420/3200
3260/2760
9700
2600
3400
38000
MHI
S16U-PTA
4831/4500
4603/4340
240 ×260
188.2
865/785
680
700
4-cycle, water cooled, turbocharged
Electric
ASTM D9775 No1D/2D or KS M 2610 No. 2 Diesel Fuel Oil
Remote Radiator or Heat Exchanger
60/50 Hz, 6P
Remote Radiator or Heat Exchanger
Water cooled by radiator
1800/1500rpm 1200/1000rpm
Phase Selection Switch, Engine Operating Switch, CB Selection Switch, Voltage Adjusting Switch, EOVR, EOCR, EUVR, Buzzer, Lamp, Push-button
Electric cell motor Air Direct Injection
V-12 V-16 V-16 V-16 I-6 I-8 V-12 V-16
2. Operating Conditions
� Ambient temperature: -15℃~40℃
� Standard altitude: below 1000 m sea level
� Relative humidity: below 85%
� Installation area: indoor (temp. 5℃~40℃)
20 21
GENSET Model60Hz50Hz
OUTPUT (kW)
Dimension (mm)
Weight (kg)
Exhaust Pipe Size (mm)
Radiator Size W×H (mm)
Ventilation Flow Rate (m2/min)
Output (BHP)Standby
Prime
Maker
Model
Type
No of Cylinders
Bore×Stroke (mm)
Cylinder Displacement (ℓ)
Governor Type
Recommended Fuel Oil
Fuel Consumption (ℓ/hr)
Recommended Lub. Oil
Lub. Oil Capacity (ℓ)
Cooling System
Coolant Capacity (ℓ)
Starting System
Type
Voltage Rating
Frequency/Pole
Phase-Wire/Power Factor
Insulation/Protection Class
Type
Control
Protection
Circuit Breaker
Meters
HEG1250AS1120AE
HEG1500AS1320AE
HEG1750AS1600AE
HEG2000AS1760AE
GENSET
Standby
Prime
rpm / Hz
Length
Width
Height
Engine
Alternator
Panel
1250/1120
1135/1020
5185
2092
2361
10815
300A
1800×1600
2012
CAT
3512TA/GSE
1818/1604
1662/1458
170×190
51.8
333/292
333
333
1500/1320
1360/1200
5737
2319
2545
12850
350A
2000×2000
2341
CAT
3512BTA/GSE
2172/1924
1971/1749
170×190
51.8
393/332
333
382
1750/1600
1600/1460
5813
2319
2545
13235
400A
2000×2000
2295
CAT
3516TA/GSE
2520/2305
2304/2095
170×190
69
442/427
416
458
2000/1760
1825/1600
6280
2319
2545
14700
400A
2000×2000
2341
CAT
3516BTA/GSE
2876/3164
2628/2293
170×190
69
500/469
416
458
Brushless self-exiting
380/220V (220/127V,440/254V,480/277V,3300V,6600V,11000V,13800V)
60/50 Hz, 4P
3PH-4W / P.F 0.8
F ( H ) / IP-20 ( IP -22, IP-23)
Free standing
Auto Control
IP-40
ACB 4P, VCB 4P
API CD or CF (SAE 15W/40)
4-cycle, water cooled, turbocharged
Electric
ASTM D9775 No1D/2D or KS M 2610 No. 2 Diesel Fuel Oil
Water cooling type by radiator
1800/1500 rpm
Wattmeter, Voltmeter, Ammeter, Frequency, Power Factor,
Electric cell motor
V-16V-16V-12V-12
Specifications 1250~5320 kW (1800/1500 rpm,900/750 rpm,720 rpm)
Specification
NOTE) 1. A genset model is based on standby output rating of alternator.
� Standby: power rating at below average 90% load for 1 hour in any 1-hour period.
No application with overload (DIN6270B)
� Prime : max. power rating at variable load for unlimited periods with overload
available for 1 hour in any 12-hour period. (DIN6270B)
HEG2000AM1725AN
HEG2660AM2285AN
HEG4000AM3460AN
HEG5320AM4580AN
HEG1680AM
-
HEG2220AM
-
HEG3360AM
-
HEG4440AM
-
2000/1725
1770/1570
9100
3900
2000
37980
450A
CAT
3606
2803
2548
280×300
111
495/427
846
900
Brushless self-exiting
380/220V (220/127V,440/254V,480/277V,3300V,6600V,11000V,13800V)
60/50 Hz, 8P
3PH-4W / P.F 0.8
F ( H ) / IP-20 ( IP -22, IP-23)
Free standing
Auto Control
IP-40
ACB 4P, VCB 4P
API CD or CF (SAE 15W/40)
2660/2285
2400/2080
9100
3950
2000
46500
450A
CAT
3608
3731
3395
280×300
148
647/556
1078
1030
4000/3460
3610/3140
9100
4100
2000
56500
600A
CAT
3612
5606
5096
280×300
222
998/863
1268
1400
5320/4580
4800/4160
10600
4300
2000
68500
650A
CAT
3616
7462
6789
280×300
296
1294/1114
1649
1660
1680
1500
9100
3900
2000
37980
450A
CAT
3606
2356
2139
280×300
111
398
846
900
2220
2000
9100
3950
2000
46500
450A
CAT
3608
3114
2833
280×300
148
530
1078
1030
3360
3050
9100
4100
2000
56500
600A
CAT
3612
4713
4278
280×300
222
796.7
1268
1400
4440
4040
10600
4300
2000
68500
650A
CAT
3616
6227
5666
280×300
296
1059
1649
1660
4-cycle, water cooled, turbocharged
Remote Radiator or Heat Exchanger
Remote Radiator or Heat Exchanger
Electric
ASTM D9775 No1D/2D or KS M 2610 No. 2 Diesel Fuel Oil
Water cooling type by radiator Water cooling type by remote radiator or by heat exchanger
60/50 Hz, 10P
900/750rpm 720rpm
Battery Voltage/Ammter, Phase SelectionSwitch, Engine Operating Switch, CB Selection Switch, Voltage Adjusting Switch, EOVR, EOCR, EUVR, Buzzer, Lamp, Push-button
Electric cell motor
I-6 I-8 V-12 V-16 I-6 I-8 V-12 V-16
2. Operating Conditions
� Ambient temperature: -15℃~40℃
� Standard altitude: below 1000 m sea level
� Relative humidity: below 85%
� Installation area: indoor (temp. 5℃~40℃)
22 23