GrowSpan Series 2000 Steel End Frame Kits

17
Revision date: 12.06.19 ©2019 GrowSpan All Rights Reserved. Reproduction is prohibited without permission. 50' Wide GrowSpan Series 2000 Steel End Frame Kits STK# GK2EW50120B 50' Wide (Base Plates) GK2EW50120G 50' Wide (No Base Plates)

Transcript of GrowSpan Series 2000 Steel End Frame Kits

Page 1: GrowSpan Series 2000 Steel End Frame Kits

Revision date: 12.06.19

©2019 GrowSpanAll Rights Reserved. Reproduction is prohibited without permission.

50' Wide

GrowSpan™ Series 2000 Steel End Frame Kits

STK#GK2EW50120B 50' Wide (Base Plates)GK2EW50120G 50' Wide (No Base Plates)

Page 2: GrowSpan Series 2000 Steel End Frame Kits

2 GK2EW50120B_G Revision date: 12.06.19

Important Information

END FRAME KIT: HOW TO USE THIS GUIDE

After assembling building main frame, attach steel end frame. Read this section to learn how best to use this guide. Not all pages apply to your end wall frame. The phrase Ground Post Option used in this guide refers to end frames that do not include base plates.

• (B) Base Plate Diagrams: Used when end wall frame includes vertical supports and base plates that will be anchored to a concrete slab or concrete piers.

• (G) Without Base Plate Diagrams: Used when end wall frame includes vertical supports that will be set below grade and anchored in place using customer-supplied concrete.

ROUGH DOOR OPENING: Materials are included to frame an opening for a pedestrian door. If a door will not be installed in the end wall, C-channel material is not used. Always confirm rough opening dimensions by reading the documentation included with door and by measuring the actual door before anchoring any framing in concrete.

ATTENTION: Customer/contractor is responsible for installing end framing to install door. Consult a qualified contractor to assist in framing an opening and to complete door installation if needed. Additional purchase required for doors and end wall cladding kits. Consult documentation with those items for additional details.

REQUIRED TOOLS

The following list identifies the main tools needed to assemble end frame. Additional tools and supports may be needed depending on the structure, location, and application.

• Tape measure or measuring device

• Marker to mark the location on tubing.

• Variable speed drill and impact driver (cordless with extra batteries works best)

• Metal file and metal-cutting saw

• Wrenches and impact socket set

• Hammers, gloves, and eye protection

• Adjustable pliers and self-locking pliers

• Ladders, work platforms, and other machinery for lifting designed to work safely at building and end frame height.

ATTENTION: Consult the services of a qualified, professional contractor if you are not familiar with constructing similar frame structures.

The individuals assembling this end frame are responsible for designing and furnishing all temporary bracing, shoring and support needed during the assembly process. For safety reasons, those who are not familiar with recognized construction methods and techniques must seek the help of a qualified contractor.

SAFETY PRECAUTIONS

• Wear eye, hand, and head protection.

• Use a portable GFCI (Ground Fault Circuit Interrupter) when working with power tools and cords.

• Do not climb on framing during or after construction.

• Do not occupy the shelter during high winds, tornadoes, or hurricanes.

• Provide adequate ventilation if the structure is enclosed.

• Do not store hazardous materials in the shelter.

• Provide proper ingress and egress to prevent entrapment.

READ THIS DOCUMENT BEFORE YOU BEGIN

Thank you for purchasing this GrowSpan™ Series 2000 Steel End Frame Kit. When properly assembled and maintained, this product will provide years of reliable service. These instructions include helpful hints and important information needed to safely assemble and properly maintain the end frame. Please read these instructions before you begin.

If you have any questions during the assembly, contact Customer Service for assistance.

Page 3: GrowSpan Series 2000 Steel End Frame Kits

3Revision date: 12.06.19 GK2EW50120B_G

Important Information

ASSEMBLY PROCEDURE

Following these instructions helps ensure proper assembly of your end frame. Steps outlining assembly are as follows:

1. Verify all parts are included in shipment. Notify Customer Service for questions or concerns.

2. Read these instructions and all additional documentation included with shipment before you begin.

3. Gather the tools, bracing, ladders (and lifts), and assistants needed to assemble end frame.

4. Check weather before you install end frame cladding (additional purchase required). Do not install cladding on a windy or stormy day.

5. Assemble end frame.

6. Read care and maintenance information (below).

7. Complete and return all warranty information as instructed (if present).

UNPACK AND IDENTIFY PARTS

The following steps help ensure you have all parts before you begin.

1. Unpack shipment and place where you can easily inventory parts. Refer to Bill of Materials/Spec Sheets.

2. Verify all parts listed on Bill of Materials/Spec Sheets are present. If anything is missing or you have questions, consult all diagrams for clarification, or contact Customer Service. NOTE: At this time, you do not need to open the plastic bags containing smaller parts such as fasteners and clamps.

CARE AND MAINTENANCE

Proper care and maintenance is important. Check these items periodically:

• Inspect all components regularly and frequently.

• Check connections and all fasteners to verify they remain tight and in good repair.

• Do not climb or stand on shelter or end frame.

• Remove debris and objects that may accumulate on the shelter. Use tools that will not damage the cover (if equipped) when removing debris.

• Remove snow to prevent excess accumulation. Use tools that will not damage the cover (if equipped) when removing snow. Never allow snow to accumulate on the cover or along sides and end panels after removing snow.

• Replace all worn or damaged parts promptly.

CUSTOMER-SUPPLIED MATERIALS

Concrete is required to anchor end wall vertical columns. Concrete is not supplied and can be purchased locally. Anchor base plates to concrete slab or piers; end wall supports without base plates are set below grade and an-chored to site using concrete.

WARNING: The individuals assembling this end frame are responsible for designing and furnishing all temporary bracing, shoring and support needed during the assembly process. For safety reasons, those who are not familiar with recognized construction methods and techniques must seek the help of a qualified contractor.

Page 4: GrowSpan Series 2000 Steel End Frame Kits

4 GK2EW50120B_G Revision date: 12.06.19

End Frame Base Plate Layout (B)

0" @

PLA

TE E

DG

E

0" @

PLA

TE E

DG

E

1 1

/2"

7 1

/2"

7'-4

1/2

"

14'

-4 1

/2"

21'

-4 1

/2"

29'

-4 1

/2"

36'

-4 1

/2"

43'

-4 1

/2"

50'

-1 1

/2"

50'

-7 1

/2"

4 1

/2"

7'-4

1/2

"

14'

-4 1

/2"

21'

-4 1

/2"

29'

-4 1

/2"

36'

-4 1

/2"

43'

-4 1

/2"

50'

-9" @

PLA

TE E

DG

E

PLATE CENTERS:

ANCHOR HOLE CENTERS:

SECTION "A-A"

111817 DETAIL(OPTIONAL)

3" 6"

5 1/2"

8" 7/8" TYP.

1 1/4"

NOTE: USE PLATE CENTERS FOR GROUND POST APPLICATION.AA

Page 5: GrowSpan Series 2000 Steel End Frame Kits

5Revision date: 12.06.19 GK2EW50120B_G

7'-0" 7'-0" 7'-0" 8'-0" 7'-0" 7'-0" 7'-0"

4'-0"

4'-0"

1'-5"

2'-7"

3'-0"

3'-0"

B

T

C1

GT

LBLB

GROUND LEVEL

TOP OF POST

B

LB LB

T

T

T

C2 C2

C1

C3 C3T

T

BB B B

GT

GT

GT

GT

GT

GT

GT

GT

GT

GTGT

GT

GT

GT

GT

GT

GT

GT

GT

GTGT

GT

GT

GTGT

GT

GT

50'-0"

NOTES:

ALL DIMENSIONS ARE FROM CENTER TO CENTER UNLESS OTHERWISE NOTED.

GIRTS/FRAMING CHANNEL MAY REQUIRE FIELD CUTTING TO FIT.ENDWALL COLUMNS:

GIRT/DOOR FRAMEGT GRT2X2G16L144 (16 GA PROFILE)

T (2X) PGBRKAAS01 (CONNECTION PLATE)

COLUMN TOP CONNECTION PLATE:

111817 (BASE PLATE)B

COLUMN BOTTOM BASE PLATE:

LATERAL BRACING BRACKET:

LB QH1070 (PIPE STRAP)

C3 PG2X4EC14L24331 (2" x 4" 14 GA 1-PLY RECT. TUBE)

PG2X4EC14L15913 (2" x 4" 14 GA 1-PLY RECT. TUBE)

PG2X4EC14L21000 (2" x 4" 14 GA 1-PLY RECT. TUBE)C2C1

End Frame Solid (B)

Page 6: GrowSpan Series 2000 Steel End Frame Kits

6 GK2EW50120B_G Revision date: 12.06.19

7'-0" 7'-0" 7'-0" 8'-0" 7'-0" 7'-0" 7'-0"

4'-0"

4'-0"

1'-5"

2'-7"

3'-0"

3'-0"

NOTES:

ALL DIMENSIONS ARE FROM CENTER TO CENTER UNLESS OTHERWISE NOTED.

SEE DOOR KIT INSTRUCTIONS FOR ADDITIONAL INSTALLATION INFORMATION (IF APPLICABLE).

GIRTS/FRAMING CHANNEL MAY REQUIRE FIELD CUTTING TO FIT.

B

T

C1

GT

VERIFYDOOR

ROUGHOPENING

H1

DBDB

LBLB

H1

H1

GROUND LEVEL

TOP OF POST

B

LB LB

T

T

T

C2 C2

C1

C3 C3T

T

BB B B

GT

GT

GT

GT

GT

GT

GT

GT

GT

GTGT

GT

GT

GT

GT

GT

GT

GT

GT

GTGT

GT

GT

GTGT

50'-0"

GRT2X2G16L144 (16 GA PROFILE)GTGIRT/DOOR FRAME

ENDWALL COLUMNS:

H1 105488 (2" C-CHANNEL)

DB QH1330 (FRAME BRACKET)

C1C2 PG2X4EC14L21000 (2" x 4" 14 GA 1-PLY RECT. TUBE)

PG2X4EC14L15913 (2" x 4" 14 GA 1-PLY RECT. TUBE)

COLUMN BOTTOM BASE PLATE:B 111817 (BASE PLATE)

COLUMN TOP CONNECTION PLATE:T (2X) PGBRKAAS01 (CONNECTION PLATE)

QH1070 (PIPE STRAP)LB

LATERAL BRACING BRACKET:

PG2X4EC14L24331 (2" x 4" 14 GA 1-PLY RECT. TUBE)C3

End Frame Diagram: Door Frame (B)

Page 7: GrowSpan Series 2000 Steel End Frame Kits

7Revision date: 12.06.19 GK2EW50120B_G

7'-0" 7'-0" 7'-0" 8'-0" 7'-0" 7'-0" 7'-0"

4'-0"

4'-0"

1'-5"

1'-1 3/8"

3'-0"

4'-0"

QH1070 (PIPE STRAP)LB

LATERAL BRACING BRACKET:

COLUMN BOTTOM BASE PLATE:B 111817 (BASE PLATE)

COLUMN TOP CONNECTION PLATE:(2X) PGBRKAAS01 (CONNECTION PLATE)T

GRT2X2G16L144 (16 GA PROFILE)GTGIRT/DOOR FRAME

ENDWALL COLUMNS:

C3 PG2X4EC14L24331 (2" x 4" 14 GA 1-PLY RECT. TUBE)

PG2X4EC14L15913 (2" x 4" 14 GA 1-PLY RECT. TUBE)

PG2X4EC14L21000 (2" x 4" 14 GA 1-PLY RECT. TUBE)C2C1

NOTES:

ALL DIMENSIONS ARE FROM CENTER TO CENTER UNLESS OTHERWISE NOTED.

GIRTS/FRAMING CHANNEL MAY REQUIRE FIELD CUTTING TO FIT.

B

T

C1

GT

LBLB

GROUND LEVEL

TOP OF POST

B

LB LB

T

T

T

C2 C2

C1

C3 C3T

T

BB B B

GT

GT

GT

GT

GT

GT

GT

GT

GT

GTGT

GT

GT

GT

GT

GT

GT

GT

GT

GTGT

GT

GT

GT

GT

GT

GT

50'-0"

Vent End Frame Diagram (B)IMPORTANT: IF A GUILLOTINE VENT WAS PURCHASED TO INSTALL IN THE END WALL, CONSULT THE INSTRUCTIONS INCLUDED WITH THAT KIT FOR REQUIRED VENT DIMENSIONS AS THEY MAY DIFFER FROM THOSE SHOWN.

Page 8: GrowSpan Series 2000 Steel End Frame Kits

8 GK2EW50120B_G Revision date: 12.06.19

End Frame (G): Vertical Supports Layout

7'-0" 8'-0" 7'-0" 7'-0" 7'-0" 7'-0" 7'-0"

50'-0"

Concrete to anchor vertical supports (required).

Page 9: GrowSpan Series 2000 Steel End Frame Kits

9Revision date: 12.06.19 GK2EW50120B_G

4'-0"

4'-0"

1'-5"

2'-7"

3'-0"

3'-0"

7'-0" 8'-0" 7'-0" 7'-0" 7'-0"

5/8" FROM GROUND LEVELTO BOTTOM OF COLUMN

2'-0"EMBEDMENT 7'-0" 7'-0"

NOTES:

ALL DIMENSIONS ARE FROM CENTER TO CENTER UNLESS OTHERWISE NOTED.

GIRTS/FRAMING CHANNEL MAY REQUIRE FIELD CUTTING TO FIT.ENDWALL COLUMNS:

GIRT/DOOR FRAMEGT GRT2X2G16L144 (16 GA PROFILE)

T (2X) PGBRKAAS01 (CONNECTION PLATE)

COLUMN TOP CONNECTION PLATE:

N/AB

COLUMN BOTTOM GROUND POST INSERT:

LATERAL BRACING BRACKET:

LB QH1070 (PIPE STRAP)

C1C2 PG2X4EC14L21000 (2" x 4" 14 GA 1-PLY RECT. TUBE)

PG2X4EC14L18375 (2" x 4" 14 GA 1-PLY RECT. TUBE)

PG2X4EC14L24331 (2" x 4" 14 GA 1-PLY RECT. TUBE)C3

T

C1

GT

LBLB

GROUND LEVEL

TOP OF POSTLB LB

T

T

T

C2 C2

C1

C3 C3T

T

GT

GT

GT

GT

GT

GT

GT

GT

GT

GTGT

GT

GT

GT

GT

GT

GT

GT

GT

GTGT

GT

GT

GTGT

GT

GT

50'-0"

End Frame Solid (G)ATTENTION: See End Frame Connections Details 1-4 showing how to anchor vertical end wall columns in concrete.

Page 10: GrowSpan Series 2000 Steel End Frame Kits

10 GK2EW50120B_G Revision date: 12.06.19

4'-0"

4'-0"

1'-5"

2'-7"

3'-0"

3'-0"

7'-0" 8'-0" 7'-0" 7'-0" 7'-0"

5/8" FROM GROUND LEVELTO BOTTOM OF COLUMN

2'-0"EMBEDMENT 7'-0" 7'-0"

NOTES:

ALL DIMENSIONS ARE FROM CENTER TO CENTER UNLESS OTHERWISE NOTED.

SEE DOOR KIT INSTRUCTIONS FOR ADDITIONAL INSTALLATION INFORMATION (IF APPLICABLE).

GIRTS/FRAMING CHANNEL MAY REQUIRE FIELD CUTTING TO FIT.

GRT2X2G16L144 (16 GA PROFILE)GTGIRT/DOOR FRAME

ENDWALL COLUMNS:

H1 105488 (2" C-CHANNEL)

COLUMN BOTTOM GROUND POST INSERT:B N/A

COLUMN TOP CONNECTION PLATE:T (2X) PGBRKAAS01 (CONNECTION PLATE)

QH1070 (PIPE STRAP)LB

LATERAL BRACING BRACKET:

C3 PG2X4EC14L24331 (2" x 4" 14 GA 1-PLY RECT. TUBE)

PG2X4EC14L18375 (2" x 4" 14 GA 1-PLY RECT. TUBE)

PG2X4EC14L21000 (2" x 4" 14 GA 1-PLY RECT. TUBE)C2C1

T

C1

GT

VERIFYDOOR

ROUGHOPENING

H1

DBDB

LBLB

H1

H1

GROUND LEVEL

TOP OF POSTLB LB

T

T

T

C2 C2

C1

C3 C3T

T

GT

GT

GT

GT

GT

GT

GT

GT

GT

GTGT

GT

GT

GT

GT

GT

GT

GT

GT

GTGT

GT

GT

GTGT

50'-0"

End Frame Diagram: Door Frame (G)

Page 11: GrowSpan Series 2000 Steel End Frame Kits

11Revision date: 12.06.19 GK2EW50120B_G

4'-0"

4'-0"

1'-5"

1'-1 3/8"

3'-0"

4'-0"

7'-0" 8'-0" 7'-0" 7'-0" 7'-0"

5/8" FROM GROUND LEVELTO BOTTOM OF COLUMN

2'-0"EMBEDMENT 7'-0" 7'-0"

QH1070 (PIPE STRAP)LB

LATERAL BRACING BRACKET:

COLUMN BOTTOM GROUND POST INSERT:B N/A

COLUMN TOP CONNECTION PLATE:(2X) PGBRKAAS01 (CONNECTION PLATE)T

GRT2X2G16L144 (16 GA PROFILE)GTGIRT/DOOR FRAME

ENDWALL COLUMNS:

C3 PG2X4EC14L24331 (2" x 4" 14 GA 1-PLY RECT. TUBE)

PG2X4EC14L18375 (2" x 4" 14 GA 1-PLY RECT. TUBE)

PG2X4EC14L21000 (2" x 4" 14 GA 1-PLY RECT. TUBE)C2C1

NOTES:

ALL DIMENSIONS ARE FROM CENTER TO CENTER UNLESS OTHERWISE NOTED.

GIRTS/FRAMING CHANNEL MAY REQUIRE FIELD CUTTING TO FIT.

T

C1

GT

LBLB

GROUND LEVEL

TOP OF POSTLB LB

T

T

T

C2 C2

C1

C3 C3T

T

GT

GT

GT

GT

GT

GT

GT

GT

GT

GT

GT

GT

GT

GT

GT

GT

GT

GT

GT

GT

GT

GT

GT

GT

GT

GT

GT

50'-0"

Vent End Frame Diagram (G)ATTENTION: See End Frame Connections Details 1-4 showing how to anchor vertical end wall columns in concrete.

IMPORTANT: IF A GUILLOTINE VENT WAS PURCHASED TO INSTALL IN THE END WALL, CONSULT THE INSTRUCTIONS INCLUDED WITH THAT KIT FOR REQUIRED VENT DIMENSIONS AS THEY MAY DIFFER FROM THOSE SHOWN.

Page 12: GrowSpan Series 2000 Steel End Frame Kits

12 GK2EW50120B_G Revision date: 12.06.19

VIEW 1 - COLUMN TO BASE PLATE/GIRT (BASE PLATE OPTION)VIEW 1A - COLUMN TO GIRT (GROUND POST OPTION)

VIEW 2 - COLUMN TO TOP CHORD

VIEW 3 - COLUMN TO GIRT (NON-SPLICE)

VIEW 4 - LATERAL BRACE TO COLUMN

End Frame Connections (B & G)

Page 13: GrowSpan Series 2000 Steel End Frame Kits

13Revision date: 12.06.19 GK2EW50120B_G

ENDWALL COLUMN

ENDWALL GIRT

-(2X) #14 X 1" TEK SCREW

VIEW 3COLUMN TO GIRT (NON-SPLICE)

-(4X) #14 X 1" TEK SCREW

ENDWALL COLUMN

ENDWALL GIRT

ENDWALL GIRT

CONCRETE PIER

VIEW 1ACOLUMN TO GIRT

(GROUND POST OPTION)

VIEW 1COLUMN TO BASE PLATE/GIRT

(BASE PLATE OPTION)

-(1X) BASE PLATE (111817)-(1X) 1/2" X 3" HEX BOLT (A325)-(2X) 1/2" WASHER (STRUCTURAL)-(1X) 1/2" NUT (STRUCTURAL)

-(4X) #14 X 1" TEK SCREW

ENDWALL GIRT

ENDWALL GIRTENDWALL COLUMN

TOP CHORD

ENDWALL COLUMN

-(2X) CONNECTION PLATE (PGBRKAAS01)-(2X) 1/2" X 3" HEX BOLT (A325)-(4X) 1/2" WASHER (STRUCTURAL)-(2X) 1/2" NUT (STRUCTURAL)

VIEW 2COLUMN TO TOP CHORD

NOTE: FIELD DRILL (1X) 9/16" HOLE THRU BOTH WALLS OF TOP CHORD.

-(1X) BRACKET (QH1070)-(3X) #14 X 1" TEK SCREW

ENDWALL COLUMN

LATERAL BRACE

VIEW 4LATERAL BRACE TO COLUMN

End Frame Connections Details 1-4 (B & G)

Page 14: GrowSpan Series 2000 Steel End Frame Kits

14 GK2EW50120B_G Revision date: 12.06.19

VIEW 1 - DOOR JAMB TO GIRT(ONLY APPLIES TO DOOR ENDWALL OPTION)

VIEW 2 - DOOR HEADER TO JAMB(ONLY APPLIES TO DOOR ENDWALL OPTION)

VIEW 3 - DOOR JAMB ANCHOR/GIRT (BASE PLATE OPTION)(ONLY APPLIES TO DOOR ENDWALL OPTION)

ATTENTION: Actual position of QH1330 bracket may differ and depends on how purchased door is secured to door frame.

End Frame Connections—Door Option (B & G)

Page 15: GrowSpan Series 2000 Steel End Frame Kits

15Revision date: 12.06.19 GK2EW50120B_G

VIEW 1DOOR JAMB TO GIRT

(ONLY APPLIES TO DOOR ENDWALL OPTION)

VIEW 2DOOR HEADER TO JAMB

(ONLY APPLIES TO DOOR ENDWALL OPTION)

VIEW 3DOOR JAMB ANCHOR/GIRT

(ONLY APPLIES TO DOOR ENDWALL OPTION)

DOOR JAMB ("C" CHANNEL)NOTE: THIS PART TO BE CUT IN FIELD TO FIT SO TAB SITSFLUSH AGAINST GIRT

ENDWALL GIRT

- (2X) WAFER HEAD SCREW #10 X 3/4

DOOR JAMB ("C" CHANNEL)

DOOR HEADER ("C" CHANNEL)NOTE: THIS PART TO BE CUT IN FIELD TO FIT

- (1X) #14 X 1" TEK SCREW

- (1X) #14 X 1" TEK SCREW

- (2X) WAFER HEAD SCREW #10 X 3/4

- (2X) WAFER HEAD SCREW #10 X 3/4

NOTE: BEND TAB UP 90°

DOOR JAMB ("C" CHANNEL)

ENDWALL GIRT

-(1X) BRACKET (QH1330)-(2X) #14 X 1" TEK SCREW

- (2X) WAFER HEAD SCREW #10 X 3/4

NOTE: FEILD CUT TWO SLITSTO CREATE A TAB

End Frame Connections Details 1-3—Door Option (B & G)

Page 16: GrowSpan Series 2000 Steel End Frame Kits

16 GK2EW50120B_G Revision date: 12.06.19

XR2535]ALUMINUM ANGLE [

ALUMINUM ANGLE TO BE FIELD CUT TO FIT(BASED ON ENDWALL OPTION)

ALUMINUM ANGLE [XR2535]

ENDWALL COLUMN BASE PLATE

ENDWALL GIRT

ENDWALL COLUMN

SIDE VIEW

ALUMINUM ANGLE DETAIL AT COLUMN BASE PLATE

- (2X) #14 X 1" TEK SCREW

NOTE: ALUMINUM ANGLE SHALLBE FLUSH TO THE GIRT FACEAND FIELD CUT TO FIT.

NOTE: INSTALL ALUMINUMTUBE PRIOR TO ATTACHINGBOTTOM RUN OF ENDWALLGIRTS.

NOTE: ALUMINUM TUBE ONLYTO BE USED WHEN ATTACHINGPOLYCARBONATE PANELS TOCONCRETE PAD.

- (1X) 3 1/4" TAPCON SCREW [FA7165](SPACE AT MAX. 12" O.C.)

NOTE: POLYURETHANE SEALANT TO BE USED @ BASE OF ALUMINUM TUBE

GIRT

BASE PLATE (OPTION)

COLUMN

1" X 1 1/2" ALUMINUM TUBE [113301]FOR USE WITH BASE PLATE OPTION ONLY

Aluminum Angle Installation Option—Base Plates Only (B)

PANEL

ATTACH PANEL TO OUTSIDE OF GIRT AND ALUMINUM.

IN SOME INSTANCES, ALUMINUM ANGLE IS REPLACED WITH 113301 ALUMINUM TUBING. SEE NEXT PAGE.

ATTENTION: INSTALL BOTTOM RUN OF GIRT AFTER INSTALLING THE ALUMINUM ANGLE.

PRE-DRILL MOUNTING HOLES IN ALUMINUM; SPACE AT 12"-16" ON CENTER.

APPLY SEALANT (112263) UNDER ALUMINUM THEN SECURE TO CONCRETE USING CONCRETE FASTENERS INCLUDED WITH KIT.

TO PREVENT LEAKS AT THIS CONNECTION, INSTALL PC PANEL OVER GIRT AND ALUMINUM.

DO NOT INSTALL BEHIND ALUMINUM.

APPLY SEALANT UNDER AND ALONG ALUMINUM.

Page 17: GrowSpan Series 2000 Steel End Frame Kits

17Revision date: 12.06.19 GK2EW50120B_G

NOTE: INSTALL ALUMINUMTUBE PRIOR TO ATTACHINGBOTTOM RUN OF ENDWALLGIRTS.

NOTE: ALUMINUM TUBE ONLYTO BE USED WHEN ATTACHINGPOLYCARBONATE PANELS TOCONCRETE PAD.

ALUMINUM TUBE DETAIL AT COLUMN BASE PLATEDETAIL "B"

ALUMINUM TUBE [113301]

ALUMINUM TUBE TO BE FIELD CUT TO FIT(BASED ON ENDWALL OPTION)

B

A

A

- (1X) 3 1/4" TAPCON SCREW [FA7165](SPACE AT MAX. 12" O.C.)

NOTE: POLYURETHANE SEALANT TO BE USED @ BASE OF ALUMINUM TUBE

GIRT

BASE PLATE (OPTION)

COLUMN

1" X 1 1/2" ALUMINUM TUBE [113301]FOR USE WITH BASE PLATE OPTION ONLY

ALUMINUM TUBE [113301]

ENDWALL COLUMN BASE PLATE

ENDWALL GIRT

ENDWALL COLUMN

SECTION "A-A"

GLAZING LINE

Aluminum Square Tube Installation Option—Base Plates Only (B)

PANEL

ATTENTION: INSTALL BOTTOM RUN OF GIRT AFTER INSTALLING THE TUBING.

PRE-DRILL MOUNTING HOLES IN ALUMINUM; SPACE AT 12"-16" ON CENTER.

APPLY SEALANT (112263) UNDER ALUMINUM THEN SECURE TO CONCRETE USING CONCRETE FASTENERS INCLUDED WITH KIT.

TO PREVENT LEAKS AT THIS CONNECTION, INSTALL PC PANEL OVER GIRT AND ALUMINUM.

DO NOT INSTALL BEHIND ALUMINUM.

APPLY SEALANT UNDER AND ALONG ALUMINUM.

ATTACH PANEL TO OUTSIDE OF GIRT AND ALUMINUM.