GROUND INVESTIGATION REPORT (FACTUAL)
Transcript of GROUND INVESTIGATION REPORT (FACTUAL)
Report Title: Cliff Stabilisation Programme, King’s Parade, Clacton, Essex May 2020 Ground Investigation Report (Factual) Report No: END20-031 P a g e | 1
Endeavour Drilling Ltd Unit 7, Mapledean Industrial Estate Maldon Road Latchingdon Essex CM3 6LG
GROUND INVESTIGATION REPORT (FACTUAL)
Client: Tendering District Council
May 2020
Cliff Stabilisation Programme, King’s Parade,
Clacton, Essex,
CO15 5QG
Report No: END20-031
Report Title: Cliff Stabilisation Programme, King’s Parade, Clacton, Essex May 2020 Ground Investigation Report (Factual) Report No: END20-031 P a g e | 2
GROUND INVESTIGATION REPORT (FACTUAL) Cliff Stabilisation Programme, Kings Parade, Clacton, Essex Author: Oliver Wendland BSc (Hons), FGS
Signed:
Checked By: Matthew Somerville BSc (Hons), FGS, CGeol
Signed:
Revision Date Description Prepared Checked
Preliminary 26.05.20 Factual Report OW MJS
Report Title: Cliff Stabilisation Programme, King’s Parade, Clacton, Essex May 2020 Ground Investigation Report (Factual) Report No: END20-031 P a g e | 3
CONTENTS:- 1. INTRODUCTION ................................................................................. 4
2. LIMITATIONS ...................................................................................... 4
3. FIELDWORK ....................................................................................... 5
4. LABORATORY TESTING .................................................................... 7
APPENDIX:- APPENDIX A: SITE LOCATION PLANS
APPENDIX B: CABLE PERCUSSIVE BOREHOLE RECORDS
APPENDIX C: INCLINOMETER GRAPHICAL DATA
APPENDIX D: INCLINOMETER NUMERICAL DATA
APPENDIX E: GROUNDWATER MONITORING RESULTS
APPENDIX F: INCLINOMETER CALIBRATION CERTIFICATE
APPENDIX G: GEOTECHNICAL LABORATORY TEST RESULTS
Report Title: Cliff Stabilisation Programme, King’s Parade, Clacton, Essex May 2020 Ground Investigation Report (Factual) Report No: END20-031
P a g e | 4
1. INTRODUCTION
Endeavour Drilling Ltd (ED) received instruction to carry out ground investigationsto aid in the design of a cliff stabilisation programme located in two separate areasalong Kings Parade, Clacton, Essex. The nearest postcode to the site is CO155QG.
The ground investigation was instructed by the Consulting Engineers, Hestur Ltd,on behalf of the client, Tendering District Council and comprised of six cablepercussive boreholes with associated sampling and in-situ testing. Laboratorytesting, comprising of geotechnical testing was also undertaken.
To allow for a longer term assessment of the cliff’s movement and groundwaterconditions, two inclinometers and four semi-permanent groundwater standpipeswere installed within the boreholes.
At the time of reporting, both the inclinometer and groundwater monitoring hasbeen performed five times over a period of six weeks. A further five visits will becompleted at dates stipulated by the client and on completion these results will bepresented in a revised report.
This report presents the factual findings of the investigation, along with themonitoring and laboratory test results undertaken.
Where applicable, investigation techniques, sampling, logging of soils and in-situtesting complied with the requirements of British Standard BS5930: 2015 – ‘Codeof Practice for Site Investigations’.
2. LIMITATIONS
This report is based on the results of the cable percussive boreholes and thelaboratory testing carried out on samples recovered from these exploratory holesand on details of the scheme provided by the Client.
This report has been prepared for the benefit of Tendering District Council and itscontents should not be relied upon by others without the written authority of ED. Ifany unauthorised third party makes use of this report they do so at their own riskand ED owes them no duty of care or skill.
All information provided by others is taken as being in good faith accurate, but EDcannot, and does not accept any liability for the detailed accuracy, errors oromissions in such information.
Report Title: Cliff Stabilisation Programme, King’s Parade, Clacton, Essex May 2020 Ground Investigation Report (Factual) Report No: END20-031 P a g e | 5
Subsoils are by their nature hidden from view and no investigation can be exhaustive to the extent that all soil conditions are revealed. Conditions may well be present beneath the site which was not evident from the investigations carried out.
Groundwater levels can be subject to considerable seasonal variations, and the conditions encountered in the exploratory boreholes may not reflect long-term conditions.
3. FIELDWORK
The fieldwork was undertaken between the 1st and 8th of April 2020 and comprised of six cable percussive boreholes, drilled with conventional 150mm casing and tooling to depths ranging from 5.00mbgl (BH05) to 20.00mbgl (BH01 & BH03), with associated sampling and in-situ testing.
To allow for a longer term assessment of the cliff’s movement and groundwater conditions, two inclinometers and four semi-permanent groundwater standpipes were installed within the boreholes.
The exploratory holes were all positioned by the client, Hestur Consulting Engineers Ltd prior to undertaking the fieldwork. An exploratory hole location plan is presented as Figure 1, in Appendix A.
3.1. Cable Percussive Boreholes
The positions were CAT scanned for the presence of underground buried services and an inspection pit excavated to a depth of 1.20mbgl to identify the presence of any buried services.
Disturbed samples were recovered throughout the boreholes for possible future geotechnical testing.
It should be noted that no insitu testing was performed in BH2 or BH5 given their close proximity to BH1 and BH6. Within all the remaining boreholes, standard penetration tests (SPT) were carried out at regular intervals, using an automatic trip hammer. The number of blows required to advance the cone over the final 300mm of a 450mm total drive was recorded and is shown as the penetration resistance (“N” value).
Undisturbed 100mm diameter samples were taken in cohesive soils using a plastic thick wall sampler (OS-T/W) at alternating intervals. A sample of the cutting shoe was retained.
Report Title: Cliff Stabilisation Programme, King’s Parade, Clacton, Essex May 2020 Ground Investigation Report (Factual) Report No: END20-031 P a g e | 6
Upon completion, the grid references and elevations relative to ordnance datum was surveyed by ED, with a Topcon DGPS.
The cable percussive borehole records are presented in Appendix B and give both descriptions and depths of strata encountered, together with details of samples taken, in-situ tests and any other relevant information.
3.2. Groundwater Installations
No groundwater was encountered during drilling operations, however, to allow for a longer-term assessment four boreholes were installed with 50mm diameter HDPE groundwater standpipes and finished at surface with a flush cover. Table 1, below summarises the design details:
Table 1: Groundwater Standpipe Design
BH No. Slotted Section (mbgl) Plain Section (mbgl)
Gravel Surround (mbgl)
Bentonite Seal (mbgl)
BH2 1.00m to 6.00m 0.00m to 1.00m 1.00m to 6.00m 0.20m to 1.00m
BH3 1.00m to 7.50m 0.00m to 1.00m 1.00m to 7.50m 0.20m to 1.00m
BH4 1.00m to 5.00m 0.00m to 1.00m 1.00m to 5.00m 0.20m to 1.00m
BH5 1.00m to 5.00m 0.00m to 1.00m 1.00m to 5.00m 0.20m to 1.00m,
3.3. Inclinometer Installations
On drilling completion, two boreholes, BH1 and BH6 were installed with 70mm outside diameter, Geosense Quick Jointing inclinometer casing to depths specified by the client.
The inclinometer casing system has four internal grooves formed at 90 degrees into the internal surface into which a portable inclinometer probe is inserted to carry out profile monitoring of the casing, which will deform with any ground movement.
During installation, a pre-blended grout mix, comprising of Bentonite powder and Portland cement in a ratio of 2 to 1 was used. Table 2, below summarises the design details:
Table 2: Inclinometer Standpipe Design
BH No. Inclinometer Section (mbgl)
BH1 0.30m to 10.00m
BH6 0.30m to 5.00m
Report Title: Cliff Stabilisation Programme, King’s Parade, Clacton, Essex May 2020 Ground Investigation Report (Factual) Report No: END20-031 P a g e | 7
3.4. Monitoring Results
At the time of reporting, both the inclinometer and groundwater monitoring has been performed five times over a period of six weeks. A further five visits will be completed at dates stipulated by the client and on completion these results will be presented in a revised report.
The results attained to date are presented in appendices C, D and E, whilst the calibration certificate of the portable inclinometer probe is presented in Appendix F.
4. LABORATORY TESTING
The laboratory testing programme comprised of geotechnical testing for use in assessing the ground conditions encountered. Chemical analysis did not form part of the brief for the investigation.
The laboratory testing was undertaken by I2 Analytical a UKAS / MCERTS accredited laboratory. The results are included in Appendix G.
4.1. Geotechnical Testing
The geotechnical laboratory testing was undertaken to provide classification and strength data on selected samples.
Twenty samples were tested for moisture content to enable the materials to be classified and their engineering behaviour assessed in accordance with BS1377, Part 2:1990; clause 3.2, 4.4, 5.3 and 5.4.
Atterberg limits were determined for twenty samples of cohesive material to enable the materials to be classified and their engineering behaviour assessed in accordance with BS1377, Part 2:1990; clause 3.2, 4.4, 5.3 and 5.4.
The undrained shear strength of the soil was determined in accordance with BS1377: Part 7: 1990, Clause 8 by the axial compression of cylindrical specimens cut from sixteen undisturbed samples.
Report Title: Cliff Stabilisation Programme, King’s Parade, Clacton, Essex May 2020 Ground Investigation Report (Factual) Report No: END20-031 P a g e | 8
APPENDIX A
Site Location Plan
Report Title: Cliff Stabilisation Programme, King’s Parade, Clacton, Essex May 2020 Ground Investigation Report (Factual) Report No: END20-031 P a g e | 9
APPENDIX B
Cable Percussive Borehole Records
Samples & In Situ Testing
Depth
0.20
0.50 - 1.000.70
1.20
1.50 - 2.00
2.50 - 3.00
3.50 - 4.00
4.30 - 4.80
4.80 - 5.30
7.00
7.50 - 7.95
8.00
9.00
10.00
Sample ID
D1
B1D2
D3
B2
B3
B4
B5
B6
D4
U1
D5
D6
D7
Test Result
HV 0.60m, 37kPa
SPT(C) 1.50m, N=20 (5,4/5,5,5,5)
SPT(C) 2.50m, N=42 (8,9/12,11,10,9)
SPT(C) 3.50m, N=50 (5,9/50 for 280mm)
SPT(S) 4.50m, N=15 (1,2/3,4,4,4)
SPT(S) 6.00m, N=17 (1,3/4,4,4,5)
Ublow=40
SPT(S) 9.00m, N=21 (2,3/5,5,5,6)
Strata DetailsLevel
(mAOD)13.26
13.0612.8612.66
10.86
9.06
8.56
Depth (m)(Thickness)
0.100.300.500.70
(1.80)
2.50
(1.80)
4.30
(0.50)
4.80
Legend Strata Description
ASPHALTMADE GROUND - Dark brown and reddish brown sandy fine to coarse, angular to sub angular gravel of flint, brick and concrete. Sand is fine to coarse.MADE GROUND - Soft light brown mottled dark blackish brown sandy very gravelly clay. Gravel is fine to coarse, angular to sub rounded of flint and brick.Firm light orangish brown slightly gravelly sandy CLAY.Medium dense brown slightly clayey gravelly fine to coarse SAND. Gravel is fine to coarse, sub angular to sub rounded of flint.
Dense light orangish brown slightly clayey very gravelly fine to coarse SAND. Gravel is fine to coarse, sub angular to sub rounded of flint.
...between 3.50 to 4.30mbgl very dense.
Firm light brown mottled orangish brown slightly sandy CLAY.
Stiff high strength dark brownish grey slightly sandy CLAY.
...below 6.0mbgl becoming fissured. Fissures are extremely closely to very closely spaced, planar with rough and smooth surfaces. Apertures are tight to open and clean.
...between 9.0mbgl to 11.00mbgl fissures are smooth with occasional polished surfaces.
1
2
3
4
5
6
7
8
9
10
GroundwaterWaterStrike
Backfill/Installation
Contract Name: Client:Kings Parade, Cliff Slip, Clacton-on-Sea Hestur
Contract Number: Date Started: Logged By: Checked By: Status:
J4280 01/04/2020 OW MJS FINAL
Borehole ID:
BH1
Sheet 1 of 2Cable Percussion
Borehole LogEasting:
620293.7Northing:
216177.1Ground Level:13.36mOD
Plant Used:Dando 150
Print Date:19/05/2020
Scale:1:50
Weather: Warm and sunny Termination: Reached target depth. SPT Hammer: AR2144Energy Ratio: N/R
Remarks:1. Location broken out at surface and hand excavated to 1.20mbgl. 2. No groundwater encountered. 3. Inclinometer installed to 10.0mbgl on completion.
HBSI CP Template Issue Number: 2 Issue Date: 09/06/2015
Start & End of Shift ObservationsDate Time Depth (m) Casing (m) Water (m)
01-04-2020 16:00 20.00 4.50
ChisellingFrom (m) To (m) Duration Remarks
Borehole DiameterDepth (m) Dia (mm)
1.20 30020.00 150
Casing DiameterDepth (m) Dia (mm)
4.50 150
InstallationTop (m) Base (m) Type Dia (mm)
0.20 10.00 PLAIN 70
Water StrikesStrike (m) Casing (m) Sealed (m) Time (mins) Rose to (m) Remarks
Samples & In Situ Testing
Depth
10.50 -10.95
11.00
12.00
13.00
13.50 -13.95
14.00
15.00
16.00
16.50 -16.95
17.00
18.00
19.00
19.50 -19.95
20.00
Sample ID
U2
D8
D9
D10
U3
D11
D12
D13
U4
D14
D15
D16
U5
D17
Test Result
Ublow=50
SPT(S) 12.00m, N=24 (3,3/5,6,6,7)
Ublow=50
SPT(S) 15.00m, N=31 (7,7/6,7,8,10)
Ublow=50
SPT(S) 18.00m, N=30 (3,5/6,7,9,8)
Ublow=55
Strata DetailsLevel
(mAOD)
-6.64
Depth (m)(Thickness)
(15.20)
20.00
Legend Strata Description
...below 13.50mbgl very stiff very high strength.
...below 19.50mbgl hard extremely high strength.
End of Borehole at 20.00m
11
12
13
14
15
16
17
18
19
20
GroundwaterWaterStrike
Backfill/Installation
Contract Name: Client:Kings Parade, Cliff Slip, Clacton-on-Sea Hestur
Contract Number: Date Started: Logged By: Checked By: Status:
J4280 01/04/2020 OW MJS FINAL
Borehole ID:
BH1
Sheet 2 of 2Cable Percussion
Borehole LogEasting:
620293.7Northing:
216177.1Ground Level:13.36mOD
Plant Used:Dando 150
Print Date:19/05/2020
Scale:1:50
Weather: Warm and sunny Termination: Reached target depth. SPT Hammer: AR2144Energy Ratio: N/R
Remarks:1. Location broken out at surface and hand excavated to 1.20mbgl. 2. No groundwater encountered. 3. Inclinometer installed to 10.0mbgl on completion.
HBSI CP Template Issue Number: 2 Issue Date: 09/06/2015
Start & End of Shift ObservationsDate Time Depth (m) Casing (m) Water (m)
01-04-2020 16:00 20.00 4.50
ChisellingFrom (m) To (m) Duration Remarks
Borehole DiameterDepth (m) Dia (mm)
1.20 30020.00 150
Casing DiameterDepth (m) Dia (mm)
4.50 150
InstallationTop (m) Base (m) Type Dia (mm)
0.20 10.00 PLAIN 70
Water StrikesStrike (m) Casing (m) Sealed (m) Time (mins) Rose to (m) Remarks
Samples & In Situ Testing
Depth
0.30
0.70
4.00
4.80
Sample ID
D1
D2
D3
D4
Test Result
Strata DetailsLevel
(mAOD)13.2513.10
12.65
9.35
8.55
7.35
Depth (m)(Thickness)
0.100.25
(0.45)
0.70
(3.30)
4.00
(0.80)
4.80
(1.20)
6.00
Legend Strata Description
ASPHALTMADE GROUND - Dark brown and reddish brown sandy fine to coarse, angular to sub angular gravel of flint, brick and concrete. Sand is fine to coarse.Firm light brown and orangish brown slightly gravelly sandy CLAY. Gravel is fine to coarse, sub angular to sub rounded of flint.Light orangish brown slightly clayey very gravelly fine to coarse SAND. Gravel is fine to coarse, sub angular to sub rounded of flint.
Firm light brown mottled orangish brown slightly sandy CLAY.
Stiff dark brownish grey slightly sandy CLAY.
End of Borehole at 6.00m
1
2
3
4
5
6
7
8
9
10
GroundwaterWaterStrike
Backfill/Installation
Contract Name: Client:Kings Parade, Cliff Slip, Clacton-on-Sea Hestur
Contract Number: Date Started: Logged By: Checked By: Status:
J4280 02/04/2020 OW MJS FINAL
Borehole ID:
BH2
Sheet 1 of 1Cable Percussion
Borehole LogEasting:
620297.3Northing:
216179.4Ground Level:13.35mOD
Plant Used:Dando 150
Print Date:19/05/2020
Scale:1:50
Weather: Warm and sunny Termination: Reached target depth.
Remarks:1. Location broken out at surface and hand excavated to 1.20mbgl. 2. No groundwater encountered. 3. No insitu testing required. 4. 50mm monitoring well installed to 6.0mbgl on completion.
HBSI CP Template Issue Number: 2 Issue Date: 09/06/2015
Start & End of Shift ObservationsDate Time Depth (m) Casing (m) Water (m)
02-04-2020 16:00 6.00 4.50
ChisellingFrom (m) To (m) Duration Remarks
Borehole DiameterDepth (m) Dia (mm)
1.20 3006.00 150
Casing DiameterDepth (m) Dia (mm)
4.50 150
InstallationTop (m) Base (m) Type Dia (mm)
0.30 1.00 PLAIN 501.00 6.00 SLOTTED 50
Water StrikesStrike (m) Casing (m) Sealed (m) Time (mins) Rose to (m) Remarks
Samples & In Situ Testing
Depth
0.20
0.50 - 1.00
1.50 - 2.00
2.50 - 3.00
3.50 - 4.00
4.50 - 5.00
5.00 - 5.50
5.50 - 6.00
6.00
7.00
7.50 - 7.95
8.00
9.00
10.00
Sample ID
D1
B1
B2
B3
B4
B5
B6
B7
D2
D3
U1
D4
D5
D6
Test Result
HV 0.70m, 70kPa
SPT(C) 1.50m, N=23 (4,4/5,4,6,8)
SPT(C) 2.50m, N=31 (1,3/5,8,8,10)
SPT(C) 4.50m, N=25 (5,7/5,7,7,6)
SPT(S) 6.00m, N=17 (2,2/4,4,4,5)
Ublow=40
SPT(S) 9.00m, N=22 (9,4/4,5,6,7)
Strata DetailsLevel
(mAOD)
13.41
13.06
12.16
11.16
8.66
8.16
Depth (m)(Thickness)
0.25(0.35)0.60
(0.90)
1.50
(1.00)
2.50
(2.50)
5.00
(0.50)
5.50
Legend Strata Description
TOPSOIL - Light brown slightly gravelly clayey fine to medium sand with frequent rootlets <2mm and roots <4mm diameter (living).MADE GROUND - Light brown slightly clayey very gravelly fine to medium sand with occasional sub angular brick cobbles. Gravel is fine to coarse, angular to sub rounded of flint.MADE GROUND Light reddish brown and dark brown sandy very cobbly, fine to coarse, angular to sub rounded gravel of brick, concrete and flint. Sand is fine to coarse.
Medium dense light orangish brown very sandy, fine to coarse, sub angular to sub rounded GRAVEL of flint. Sand is fine to coarse.
Dense light orangish brown slightly clayey SAND and GRAVEL. Sand is fine to coarse. Gravel is fine to coarse, sub angular to subrounded of flint.
...below 4.50mbgl medium dense.
Firm light brown slightly sandy CLAY.
Stiff high strength fissured dark brownish grey slightly sandy CLAY. Fissures are extremely closely to very closely spaced, planar with smooth and rough surfaces. Apertures are tight and open and clean.
...between 9.0m to 9.30mbgl thin band of weak Claystone recovered as sub angular fine to coarse gravel.
1
2
3
4
5
6
7
8
9
10
GroundwaterWaterStrike
Backfill/Installation
Contract Name: Client:Kings Parade, Cliff Slip, Clacton-on-Sea Hestur
Contract Number: Date Started: Logged By: Checked By: Status:
J4280 03/04/2020 OW MJS FINAL
Borehole ID:
BH3
Sheet 1 of 2Cable Percussion
Borehole LogEasting:
620191.1Northing:216118.8
Ground Level:13.66mOD
Plant Used:Dando 150
Print Date:19/05/2020
Scale:1:50
Weather: Warm and sunny Termination: Reached target depth. SPT Hammer: AR2144Energy Ratio: N/R
Remarks:1. Inspection pit hand excavated to 1.20mbgl. 2. No groundwater encountered. 3. 50mm monitoring well installed to 7.50mbgl on completion.
HBSI CP Template Issue Number: 2 Issue Date: 09/06/2015
Start & End of Shift ObservationsDate Time Depth (m) Casing (m) Water (m)
03-04-2020 16:00 20.00 5.50
ChisellingFrom (m) To (m) Duration Remarks
Borehole DiameterDepth (m) Dia (mm)
1.20 30020.00 150
Casing DiameterDepth (m) Dia (mm)
5.50 150
InstallationTop (m) Base (m) Type Dia (mm)
0.30 1.00 PLAIN 501.00 7.50 SLOTTED 50
Water StrikesStrike (m) Casing (m) Sealed (m) Time (mins) Rose to (m) Remarks
Samples & In Situ Testing
Depth
10.50 -10.95
11.00
12.00
13.50 -13.95
14.00
15.00
16.00
16.50 -16.95
17.00
18.00
19.00
19.50 -19.95
20.00
Sample ID
U2
D7
D8
U3
D9
D10
D11
U4
D12
D13
D14
U5
D15
Test Result
Ublow=45
SPT(S) 12.00m, N=25 (3,4/5,6,7,7)
Ublow=45
SPT(S) 15.00m, N=27 (3,3/6,6,6,9)
Ublow=50
SPT(S) 18.00m, N=27 (3,5/6,6,7,8)
Ublow=60
Strata DetailsLevel
(mAOD)
-6.34
Depth (m)(Thickness)
(14.50)
20.00
Legend Strata Description
...at 10.95mbgl fissures are smooth with polished surfaces.
...below 14.0mbgl with rare medium gravel size pyrite nodules.
...below 16.50mbgl very stiff very high strength.
End of Borehole at 20.00m
11
12
13
14
15
16
17
18
19
20
GroundwaterWaterStrike
Backfill/Installation
Contract Name: Client:Kings Parade, Cliff Slip, Clacton-on-Sea Hestur
Contract Number: Date Started: Logged By: Checked By: Status:
J4280 03/04/2020 OW MJS FINAL
Borehole ID:
BH3
Sheet 2 of 2Cable Percussion
Borehole LogEasting:
620191.1Northing:216118.8
Ground Level:13.66mOD
Plant Used:Dando 150
Print Date:19/05/2020
Scale:1:50
Weather: Warm and sunny Termination: Reached target depth. SPT Hammer: AR2144Energy Ratio: N/R
Remarks:1. Inspection pit hand excavated to 1.20mbgl. 2. No groundwater encountered. 3. 50mm monitoring well installed to 7.50mbgl on completion.
HBSI CP Template Issue Number: 2 Issue Date: 09/06/2015
Start & End of Shift ObservationsDate Time Depth (m) Casing (m) Water (m)
03-04-2020 16:00 20.00 5.50
ChisellingFrom (m) To (m) Duration Remarks
Borehole DiameterDepth (m) Dia (mm)
1.20 30020.00 150
Casing DiameterDepth (m) Dia (mm)
5.50 150
InstallationTop (m) Base (m) Type Dia (mm)
0.30 1.00 PLAIN 501.00 7.50 SLOTTED 50
Water StrikesStrike (m) Casing (m) Sealed (m) Time (mins) Rose to (m) Remarks
Samples & In Situ Testing
Depth
0.300.50 - 1.00
0.70
1.20
2.50 - 2.95
3.00
4.50 - 4.95
5.00
7.00
7.50 - 7.95
8.00
9.00
10.00
Sample ID
D1B1D2
D3
U1
D4
U2
D5
D6
U3
D7
D8
D10
Test Result
HV 0.70m, 70kPa
SPT(S) 1.50m, N=9 (1,1/2,2,2,3)
Ublow=30
SPT(S) 3.50m, N=14 (1,2/3,3,4,4)
Ublow=40
SPT(S) 6.00m, N=22 (2,4/5,4,5,8)
Ublow=50
SPT(S) 9.00m, N=29 (3,4/6,7,8,8)
Strata DetailsLevel
(mAOD)
3.953.75
3.15
1.75
-5.75
Depth (m)(Thickness)
(0.30)0.300.50
(0.60)
1.10
(1.40)
2.50
(7.50)
10.00
Legend Strata Description
CONCRETE
MADE GROUND - Light brown and yellowish brown sandy very gravelly clay. Gravel is fine to coarse, sub angular to sub rounded of brick and flint.Firm light brown and light grey slightly sandy gravelly CLAY frequently thinly laminated with fine to medium sand lenses. Gravel is fine to coarse, sub angular to sub rounded of flint.Firm light brownish grey slightly sandy CLAY.
Stiff high strength fissured dark brownish grey slightly sandy CLAY. Fissures are extremely closely to very closely spaced, planar with smooth and rough surfaces. Apertures are tight and open and clean.
...below 7.50mbgl very stiff very high strength.
End of Borehole at 10.00m
1
2
3
4
5
6
7
8
9
10
GroundwaterWaterStrike
Backfill/Installation
Contract Name: Client:Kings Parade, Cliff Slip, Clacton-on-Sea Hestur
Contract Number: Date Started: Logged By: Checked By: Status:
J4280 06/04/2020 OW MJS FINAL
Borehole ID:
BH4
Sheet 1 of 1Cable Percussion
Borehole LogEasting:
620215.7Northing:
216103.0Ground Level:
4.25mODPlant Used:Dando 150
Print Date:19/05/2020
Scale:1:50
Weather: Warm and sunny Termination: Reached target depth. SPT Hammer: AR2144Energy Ratio: N/R
Remarks:1. Location broken out at surface and hand excavated to 1.20mbgl. 2. No groundwater encountered. 3. 50mm monitoring well installed to 5.0mbgl on completion.
HBSI CP Template Issue Number: 2 Issue Date: 09/06/2015
Start & End of Shift ObservationsDate Time Depth (m) Casing (m) Water (m)
06-04-2020 16:00 10.00 2.50
ChisellingFrom (m) To (m) Duration Remarks
Borehole DiameterDepth (m) Dia (mm)
1.20 30010.00 150
Casing DiameterDepth (m) Dia (mm)
2.50 150
InstallationTop (m) Base (m) Type Dia (mm)
0.30 1.00 PLAIN 501.00 5.00 SLOTTED 50
Water StrikesStrike (m) Casing (m) Sealed (m) Time (mins) Rose to (m) Remarks
Samples & In Situ Testing
Depth
0.30
1.60
2.00
5.00
Sample ID
D1
D2
D3
D4
Test Result
Strata DetailsLevel
(mAOD)4.21
4.01
3.31
2.31
-0.69
Depth (m)(Thickness)
0.100.30
(0.70)
1.00
(1.00)
2.00
(3.00)
5.00
Legend Strata Description
ASPHALTCONCRETEMADE GROUND - Firm light brown gravelly very sandy clay. Gravel is fine to coarse, angular to sub rounded of brick, flint and concrete.
Light brown clayey gravelly fine to coarse SAND. Gravel is fine to coarse, sub angular to sub rounded of flint.
Stiff fissured dark brownish grey slightly sandy CLAY. Fissures are extremely closely to very closely spaced, planar with smooth and rough surfaces. Apertures are tight and open and clean.
End of Borehole at 5.00m
1
2
3
4
5
6
7
8
9
10
GroundwaterWaterStrike
Backfill/Installation
Contract Name: Client:Kings Parade, Cliff Slip, Clacton-on-Sea Hestur
Contract Number: Date Started: Logged By: Checked By: Status:
J4280 07/04/2020 OW MJS FINAL
Borehole ID:
BH5
Sheet 1 of 1Cable Percussion
Borehole LogEasting:
620312.4Northing:
216157.8Ground Level:
4.31mODPlant Used:Dando 150
Print Date:19/05/2020
Scale:1:50
Weather: Warm and sunny Termination: Reached target depth.
Remarks:1. Location broken out at surface and hand excavated to 1.20mbgl. 2. No groundwater encountered. 3. No insitu testing required. 4. 50mm monitoring well installed to 5.0mbgl on completion.
HBSI CP Template Issue Number: 2 Issue Date: 09/06/2015
Start & End of Shift ObservationsDate Time Depth (m) Casing (m) Water (m)
07-04-2020 16:00 5.00 2.50
ChisellingFrom (m) To (m) Duration Remarks
Borehole DiameterDepth (m) Dia (mm)
1.20 3005.00 150
Casing DiameterDepth (m) Dia (mm)
2.50 150
InstallationTop (m) Base (m) Type Dia (mm)
0.30 1.00 PLAIN1.00 5.00 SLOTTED
Water StrikesStrike (m) Casing (m) Sealed (m) Time (mins) Rose to (m) Remarks
Samples & In Situ Testing
Depth
0.300.50 - 1.00
0.70
1.20
2.50 - 2.95
3.00
3.50
4.50 - 4.95
5.00
6.00
7.00
7.50 - 7.95
8.00
9.00
10.00
Sample ID
D1B1D2
D3
U1
D4
D5
U2
D6
D7
D8
U3
D9
D10
D11
Test Result
SPT(S) 1.50m, N=14 (2,3/3,3,4,4)
Ublow=30
SPT(S) 3.50m, N=17 (2,3/4,4,4,5)
Ublow=40
SPT(S) 6.00m, N=24 (3,3/5,6,6,7)
Ublow=50
SPT(S) 9.00m, N=26 (2,3/4,7,7,8)
Strata DetailsLevel
(mAOD)4.20
4.00
2.80
-5.70
Depth (m)(Thickness)
0.100.30
(1.20)
1.50
(8.50)
10.00
Legend Strata Description
ASPHALTCONCRETEMADE GROUND - Firm light brown mottled orangish brown slightly gravelly sandy clay occasionally thickly laminated with clayey fine to coarse sand. Gravel is fine to coarse, sub angular to sub rounded of flint.
Firm medium strength fissured dark brownish grey slightly sandy CLAY with rare fine gravel sized pyrite nodules. Fissures are extremely closely to very closely spaced, planar with smooth and rough surfaces. Apertures are tight and open and clean.
...below 4.50mbgl stiff high strength.
...below 7.50mbgl very stiff very high strength.
End of Borehole at 10.00m
1
2
3
4
5
6
7
8
9
10
GroundwaterWaterStrike
Backfill/Installation
Contract Name: Client:Kings Parade, Cliff Slip, Clacton-on-Sea Hestur
Contract Number: Date Started: Logged By: Checked By: Status:
J4280 07/04/2020 OW MJS FINAL
Borehole ID:
BH6
Sheet 1 of 1Cable Percussion
Borehole LogEasting:
620308.4Northing:
216155.0Ground Level:
4.30mODPlant Used:Dando 150
Print Date:19/05/2020
Scale:1:50
Weather: Warm and sunny Termination: Reached target depth. SPT Hammer: AR2144Energy Ratio: N/R
Remarks:1. Location broken out at surface and hand excavated to 1.20mbgl. 2. No groundwater encountered. 3. Inclinometer installed to 5.0mbgl on completion.
HBSI CP Template Issue Number: 2 Issue Date: 09/06/2015
Start & End of Shift ObservationsDate Time Depth (m) Casing (m) Water (m)
07-04-2020 16:00 10.00 2.50
ChisellingFrom (m) To (m) Duration Remarks
Borehole DiameterDepth (m) Dia (mm)
1.20 30010.00 150
Casing DiameterDepth (m) Dia (mm)
2.50 150
InstallationTop (m) Base (m) Type Dia (mm)
0.30 5.00 PLAIN 50
Water StrikesStrike (m) Casing (m) Sealed (m) Time (mins) Rose to (m) Remarks
Report Title: Cliff Stabilisation Programme, King’s Parade, Clacton, Essex May 2020 Ground Investigation Report (Factual) Report No: END20-031 P a g e | 10
APPENDIX C
Inclinometer Graphical Data
Client
Location
18.05.20
Inclinometer Profile BH1
Date
Job No. J4280
Hestur Consulting Engineers Ltd
Kings Parade, Clacton, Essex
Client
Location
18.05.20
Inclinometer Profile BH6
Date
Job No. J4280
Hestur Consulting Engineers Ltd
Kings Parade, Clacton, Essex
Report Title: Cliff Stabilisation Programme, King’s Parade, Clacton, Essex May 2020 Ground Investigation Report (Factual) Report No: END20-031 P a g e | 11
APPENDIX D
Inclinometer Numerical Data
Client
Location
18.05.20
Inclinometer Profile BH1
Date
Job No. J4280
Hestur Consulting Engineers Ltd
Kings Parade, Clacton, Essex
Client
Location
18.05.20
Inclinometer Profile BH6
Date
Job No. J4280
Hestur Consulting Engineers Ltd
Kings Parade, Clacton, Essex
Report Title: Cliff Stabilisation Programme, King’s Parade, Clacton, Essex May 2020 Ground Investigation Report (Factual) Report No: END20-031 P a g e | 12
APPENDIX E
Groundwater Monitoring Results
Client:
Site: Date: Various
Borehole No.
Install Depth
(mbgl) Dipped Depth (mbgl) DATE
Water Level
(mbgl)
BH2 6.00 6.00 14.04.20 3.82
BH3 7.50 7.50 14.04.20 4.65
BH4 5.00 5.00 14.04.20 0.32
BH5 5.00 5.00 14.04.20 2.07
BH2 6.00 6.00 20.04.20 3.84
BH3 7.50 7.50 20.04.20 4.64
BH4 5.00 5.00 20.04.20 0.35
BH5 5.00 5.00 20.04.20 1.78
BH2 6.00 6.00 27.04.20 3.85
BH3 7.50 7.50 27.04.20 4.66
BH4 5.00 5.00 27.04.20 0.29
BH5 5.00 5.00 27.04.20 1.80
BH2 6.00 6.00 04.05.20 3.87
BH3 7.50 7.50 04.05.20 4.67
BH4 5.00 5.00 04.05.20 0.28
BH5 5.00 5.00 04.05.20 1.78
BH2 6.00 6.00 18.05.20 3.88
BH3 7.50 7.50 18.05.20 4.70
BH4 5.00 5.00 18.05.20 0.32
BH5 5.00 5.00 18.05.20 1.78
Water Level Readings
Hestur
Kings Parade, Cliff Slip
Report Title: Cliff Stabilisation Programme, King’s Parade, Clacton, Essex May 2020 Ground Investigation Report (Factual) Report No: END20-031 P a g e | 13
APPENDIX F
Inclinometer Calibration Certificate
Report Title: Cliff Stabilisation Programme, King’s Parade, Clacton, Essex May 2020 Ground Investigation Report (Factual) Report No: END20-031 P a g e | 14
APPENDIX G
Geotechnical Laboratory Test Results
TEST CERTIFICATE
Liquid and Plastic Limits
Tested in Accordance with: BS 1377-2: 1990: Clause 4.4 and 5
Client: Client Reference:
Client Address: Job Number:
Date Sampled:
Date Received:
Contact: Date Tested:
Site Address: Sampled By:
Testing carried out at i2 Analytical Limited, ul. Pionierow 39, 41-711 Ruda Slaska, Poland
Test Results:
Laboratory Reference: Depth Top [m]:
Hole No.: Depth Base [m]:
Sample Reference: Sample Type:
Soil Description:
Sample Preparation:
Legend, based on BS 5930:2015 Code of practice for site investigations
Plasticity Liquid Limit
C Clay L Low below 35
M Silt I Medium 35 to 50
H High 50 to 70
V Very high 70 to 90
E Extremely high exceeding 90
Organic O append to classification for organic material ( eg CHO )
Note: Moisture Content by BS 1377-2: 1990: Clause 3.2
Remarks:
Signed:
for and on behalf of i2 Analytical Ltd
Opinions and interpretations expressed herein are outside of the scope of the UKAS Accreditation. This
report may not be reproduced other than in full without the prior written approval of the issuing
laboratory. The results included within the report are representative of the samples submitted for
analysis.Page 1 of 1 Date Reported: 30/04/2020 GF 232.8
31 89 34 55 100
Tested in natural condition
As Received Moisture
Content [%]
Liquid Limit
[%]
Plastic Limit
[%]
Plasticity Index
[%]
% Passing 425µm
BS Test Sieve
BH1 Not Given
Not Given D
Brown CLAY
Matthew Somerville 20/04/2020
Hestur Kings Parade Cliff Slip Not Given
1494808 7.00
Endeavour Drilling J4280
Unit 7 Mapledean Industrial Estate, Maldon Road,
Chelmsford, CM3 6LD
20-96643
01/04/2020
16/04/2020
CL
CI
CH
CV
CE
MLMI
MH
MV
ME
A line
0
10
20
30
40
50
60
70
80
90
100
0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150
PLA
STIC
ITY
IN
DEX
LIQUID LIMIT
Szczepan BielatowiczPL Deputy of Head of Geotechnical Section
TEST CERTIFICATE
Liquid and Plastic Limits
Tested in Accordance with: BS 1377-2: 1990: Clause 4.4 and 5
Client: Client Reference:
Client Address: Job Number:
Date Sampled:
Date Received:
Contact: Date Tested:
Site Address: Sampled By:
Testing carried out at i2 Analytical Limited, ul. Pionierow 39, 41-711 Ruda Slaska, Poland
Test Results:
Laboratory Reference: Depth Top [m]:
Hole No.: Depth Base [m]:
Sample Reference: Sample Type:
Soil Description:
Sample Preparation:
Legend, based on BS 5930:2015 Code of practice for site investigations
Plasticity Liquid Limit
C Clay L Low below 35
M Silt I Medium 35 to 50
H High 50 to 70
V Very high 70 to 90
E Extremely high exceeding 90
Organic O append to classification for organic material ( eg CHO )
Note: Moisture Content by BS 1377-2: 1990: Clause 3.2
Remarks:
Signed:
for and on behalf of i2 Analytical Ltd
Opinions and interpretations expressed herein are outside of the scope of the UKAS Accreditation. This
report may not be reproduced other than in full without the prior written approval of the issuing
laboratory. The results included within the report are representative of the samples submitted for
analysis.Page 1 of 1 Date Reported: 30/04/2020 GF 232.8
29 95 32 63 100
Tested in natural condition
As Received Moisture
Content [%]
Liquid Limit
[%]
Plastic Limit
[%]
Plasticity Index
[%]
% Passing 425µm
BS Test Sieve
BH1 Not Given
Not Given D
Brown CLAY
Matthew Somerville 20/04/2020
Hestur Kings Parade Cliff Slip Not Given
1494810 9.00
Endeavour Drilling J4280
Unit 7 Mapledean Industrial Estate, Maldon Road,
Chelmsford, CM3 6LD
20-96643
01/04/2020
16/04/2020
CL
CI
CH
CV
CE
MLMI
MH
MV
ME
A line
0
10
20
30
40
50
60
70
80
90
100
0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150
PLA
STIC
ITY
IN
DEX
LIQUID LIMIT
Szczepan BielatowiczPL Deputy of Head of Geotechnical Section
TEST CERTIFICATE
Liquid and Plastic Limits
Tested in Accordance with: BS 1377-2: 1990: Clause 4.4 and 5
Client: Client Reference:
Client Address: Job Number:
Date Sampled:
Date Received:
Contact: Date Tested:
Site Address: Sampled By:
Testing carried out at i2 Analytical Limited, ul. Pionierow 39, 41-711 Ruda Slaska, Poland
Test Results:
Laboratory Reference: Depth Top [m]:
Hole No.: Depth Base [m]:
Sample Reference: Sample Type:
Soil Description:
Sample Preparation:
Legend, based on BS 5930:2015 Code of practice for site investigations
Plasticity Liquid Limit
C Clay L Low below 35
M Silt I Medium 35 to 50
H High 50 to 70
V Very high 70 to 90
E Extremely high exceeding 90
Organic O append to classification for organic material ( eg CHO )
Note: Moisture Content by BS 1377-2: 1990: Clause 3.2
Remarks:
Signed:
for and on behalf of i2 Analytical Ltd
Opinions and interpretations expressed herein are outside of the scope of the UKAS Accreditation. This
report may not be reproduced other than in full without the prior written approval of the issuing
laboratory. The results included within the report are representative of the samples submitted for
analysis.Page 1 of 1 Date Reported: 30/04/2020 GF 232.8
30 96 37 59 100
Tested in natural condition
As Received Moisture
Content [%]
Liquid Limit
[%]
Plastic Limit
[%]
Plasticity Index
[%]
% Passing 425µm
BS Test Sieve
BH1 Not Given
Not Given D
Brown CLAY
Matthew Somerville 20/04/2020
Hestur Kings Parade Cliff Slip Not Given
1494812 11.00
Endeavour Drilling J4280
Unit 7 Mapledean Industrial Estate, Maldon Road,
Chelmsford, CM3 6LD
20-96643
01/04/2020
16/04/2020
CL
CI
CH
CV
CE
MLMI
MH
MV
ME
A line
0
10
20
30
40
50
60
70
80
90
100
0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150
PLA
STIC
ITY
IN
DEX
LIQUID LIMIT
Szczepan BielatowiczPL Deputy of Head of Geotechnical Section
TEST CERTIFICATE
Liquid and Plastic Limits
Tested in Accordance with: BS 1377-2: 1990: Clause 4.4 and 5
Client: Client Reference:
Client Address: Job Number:
Date Sampled:
Date Received:
Contact: Date Tested:
Site Address: Sampled By:
Testing carried out at i2 Analytical Limited, ul. Pionierow 39, 41-711 Ruda Slaska, Poland
Test Results:
Laboratory Reference: Depth Top [m]:
Hole No.: Depth Base [m]:
Sample Reference: Sample Type:
Soil Description:
Sample Preparation:
Legend, based on BS 5930:2015 Code of practice for site investigations
Plasticity Liquid Limit
C Clay L Low below 35
M Silt I Medium 35 to 50
H High 50 to 70
V Very high 70 to 90
E Extremely high exceeding 90
Organic O append to classification for organic material ( eg CHO )
Note: Moisture Content by BS 1377-2: 1990: Clause 3.2
Remarks:
Signed:
for and on behalf of i2 Analytical Ltd
Opinions and interpretations expressed herein are outside of the scope of the UKAS Accreditation. This
report may not be reproduced other than in full without the prior written approval of the issuing
laboratory. The results included within the report are representative of the samples submitted for
analysis.Page 1 of 1 Date Reported: 30/04/2020 GF 232.8
30 87 37 50 100
Tested in natural condition
As Received Moisture
Content [%]
Liquid Limit
[%]
Plastic Limit
[%]
Plasticity Index
[%]
% Passing 425µm
BS Test Sieve
BH1 Not Given
Not Given D
Brown CLAY
Matthew Somerville 20/04/2020
Hestur Kings Parade Cliff Slip Not Given
1494813 13.00
Endeavour Drilling J4280
Unit 7 Mapledean Industrial Estate, Maldon Road,
Chelmsford, CM3 6LD
20-96643
01/04/2020
16/04/2020
CL
CI
CH
CV
CE
MLMI
MH
MV
ME
A line
0
10
20
30
40
50
60
70
80
90
100
0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150
PLA
STIC
ITY
IN
DEX
LIQUID LIMIT
Szczepan BielatowiczPL Deputy of Head of Geotechnical Section
TEST CERTIFICATE
Liquid and Plastic Limits
Tested in Accordance with: BS 1377-2: 1990: Clause 4.4 and 5
Client: Client Reference:
Client Address: Job Number:
Date Sampled:
Date Received:
Contact: Date Tested:
Site Address: Sampled By:
Testing carried out at i2 Analytical Limited, ul. Pionierow 39, 41-711 Ruda Slaska, Poland
Test Results:
Laboratory Reference: Depth Top [m]:
Hole No.: Depth Base [m]:
Sample Reference: Sample Type:
Soil Description:
Sample Preparation:
Legend, based on BS 5930:2015 Code of practice for site investigations
Plasticity Liquid Limit
C Clay L Low below 35
M Silt I Medium 35 to 50
H High 50 to 70
V Very high 70 to 90
E Extremely high exceeding 90
Organic O append to classification for organic material ( eg CHO )
Note: Moisture Content by BS 1377-2: 1990: Clause 3.2
Remarks:
Signed:
for and on behalf of i2 Analytical Ltd
Opinions and interpretations expressed herein are outside of the scope of the UKAS Accreditation. This
report may not be reproduced other than in full without the prior written approval of the issuing
laboratory. The results included within the report are representative of the samples submitted for
analysis.Page 1 of 1 Date Reported: 30/04/2020 GF 232.8
29 83 32 51 100
Tested in natural condition
As Received Moisture
Content [%]
Liquid Limit
[%]
Plastic Limit
[%]
Plasticity Index
[%]
% Passing 425µm
BS Test Sieve
BH1 Not Given
Not Given D
Brown CLAY
Matthew Somerville 20/04/2020
Hestur Kings Parade Cliff Slip Not Given
1494815 16.00
Endeavour Drilling J4280
Unit 7 Mapledean Industrial Estate, Maldon Road,
Chelmsford, CM3 6LD
20-96643
01/04/2020
16/04/2020
CL
CI
CH
CV
CE
MLMI
MH
MV
ME
A line
0
10
20
30
40
50
60
70
80
90
100
0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150
PLA
STIC
ITY
IN
DEX
LIQUID LIMIT
Szczepan BielatowiczPL Deputy of Head of Geotechnical Section
TEST CERTIFICATE
Liquid and Plastic Limits
Tested in Accordance with: BS 1377-2: 1990: Clause 4.4 and 5
Client: Client Reference:
Client Address: Job Number:
Date Sampled:
Date Received:
Contact: Date Tested:
Site Address: Sampled By:
Testing carried out at i2 Analytical Limited, ul. Pionierow 39, 41-711 Ruda Slaska, Poland
Test Results:
Laboratory Reference: Depth Top [m]:
Hole No.: Depth Base [m]:
Sample Reference: Sample Type:
Soil Description:
Sample Preparation:
Legend, based on BS 5930:2015 Code of practice for site investigations
Plasticity Liquid Limit
C Clay L Low below 35
M Silt I Medium 35 to 50
H High 50 to 70
V Very high 70 to 90
E Extremely high exceeding 90
Organic O append to classification for organic material ( eg CHO )
Note: Moisture Content by BS 1377-2: 1990: Clause 3.2
Remarks:
Signed:
for and on behalf of i2 Analytical Ltd
Opinions and interpretations expressed herein are outside of the scope of the UKAS Accreditation. This
report may not be reproduced other than in full without the prior written approval of the issuing
laboratory. The results included within the report are representative of the samples submitted for
analysis.Page 1 of 1 Date Reported: 30/04/2020 GF 232.8
30 98 39 59 100
Tested in natural condition
As Received Moisture
Content [%]
Liquid Limit
[%]
Plastic Limit
[%]
Plasticity Index
[%]
% Passing 425µm
BS Test Sieve
BH1 Not Given
Not Given B
Brown CLAY
Matthew Somerville 20/04/2020
Hestur Kings Parade Cliff Slip Not Given
1494817 19.00
Endeavour Drilling J4280
Unit 7 Mapledean Industrial Estate, Maldon Road,
Chelmsford, CM3 6LD
20-96643
01/04/2020
16/04/2020
CL
CI
CH
CV
CE
MLMI
MH
MV
ME
A line
0
10
20
30
40
50
60
70
80
90
100
0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150
PLA
STIC
ITY
IN
DEX
LIQUID LIMIT
Szczepan BielatowiczPL Deputy of Head of Geotechnical Section
TEST CERTIFICATE
Liquid and Plastic Limits
Tested in Accordance with: BS 1377-2: 1990: Clause 4.4 and 5
Client: Client Reference:
Client Address: Job Number:
Date Sampled:
Date Received:
Contact: Date Tested:
Site Address: Sampled By:
Testing carried out at i2 Analytical Limited, ul. Pionierow 39, 41-711 Ruda Slaska, Poland
Test Results:
Laboratory Reference: Depth Top [m]:
Hole No.: Depth Base [m]:
Sample Reference: Sample Type:
Soil Description:
Sample Preparation:
Legend, based on BS 5930:2015 Code of practice for site investigations
Plasticity Liquid Limit
C Clay L Low below 35
M Silt I Medium 35 to 50
H High 50 to 70
V Very high 70 to 90
E Extremely high exceeding 90
Organic O append to classification for organic material ( eg CHO )
Note: Moisture Content by BS 1377-2: 1990: Clause 3.2
Remarks:
Signed:
for and on behalf of i2 Analytical Ltd
Opinions and interpretations expressed herein are outside of the scope of the UKAS Accreditation. This
report may not be reproduced other than in full without the prior written approval of the issuing
laboratory. The results included within the report are representative of the samples submitted for
analysis.Page 1 of 1 Date Reported: 30/04/2020 GF 232.8
32 87 38 49 100
Tested in natural condition
As Received Moisture
Content [%]
Liquid Limit
[%]
Plastic Limit
[%]
Plasticity Index
[%]
% Passing 425µm
BS Test Sieve
BH3 Not Given
Not Given D
Brown CLAY
Matthew Somerville 20/04/2020
Hestur Kings Parade Cliff Slip Not Given
1494819 6.00
Endeavour Drilling J4280
Unit 7 Mapledean Industrial Estate, Maldon Road,
Chelmsford, CM3 6LD
20-96643
03/04/2020
16/04/2020
CL
CI
CH
CV
CE
MLMI
MH
MV
ME
A line
0
10
20
30
40
50
60
70
80
90
100
0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150
PLA
STIC
ITY
IN
DEX
LIQUID LIMIT
Szczepan BielatowiczPL Deputy of Head of Geotechnical Section
TEST CERTIFICATE
Liquid and Plastic Limits
Tested in Accordance with: BS 1377-2: 1990: Clause 4.4 and 5
Client: Client Reference:
Client Address: Job Number:
Date Sampled:
Date Received:
Contact: Date Tested:
Site Address: Sampled By:
Testing carried out at i2 Analytical Limited, ul. Pionierow 39, 41-711 Ruda Slaska, Poland
Test Results:
Laboratory Reference: Depth Top [m]:
Hole No.: Depth Base [m]:
Sample Reference: Sample Type:
Soil Description:
Sample Preparation:
Legend, based on BS 5930:2015 Code of practice for site investigations
Plasticity Liquid Limit
C Clay L Low below 35
M Silt I Medium 35 to 50
H High 50 to 70
V Very high 70 to 90
E Extremely high exceeding 90
Organic O append to classification for organic material ( eg CHO )
Note: Moisture Content by BS 1377-2: 1990: Clause 3.2
Remarks:
Signed:
for and on behalf of i2 Analytical Ltd
Opinions and interpretations expressed herein are outside of the scope of the UKAS Accreditation. This
report may not be reproduced other than in full without the prior written approval of the issuing
laboratory. The results included within the report are representative of the samples submitted for
analysis.Page 1 of 1 Date Reported: 30/04/2020 GF 232.8
30 92 33 59 100
Tested in natural condition
As Received Moisture
Content [%]
Liquid Limit
[%]
Plastic Limit
[%]
Plasticity Index
[%]
% Passing 425µm
BS Test Sieve
BH3 Not Given
Not Given D
Brown CLAY
Matthew Somerville 20/04/2020
Hestur Kings Parade Cliff Slip Not Given
1494821 8.00
Endeavour Drilling J4280
Unit 7 Mapledean Industrial Estate, Maldon Road,
Chelmsford, CM3 6LD
20-96643
03/04/2020
16/04/2020
CL
CI
CH
CV
CE
MLMI
MH
MV
ME
A line
0
10
20
30
40
50
60
70
80
90
100
0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150
PLA
STIC
ITY
IN
DEX
LIQUID LIMIT
Szczepan BielatowiczPL Deputy of Head of Geotechnical Section
TEST CERTIFICATE
Liquid and Plastic Limits
Tested in Accordance with: BS 1377-2: 1990: Clause 4.4 and 5
Client: Client Reference:
Client Address: Job Number:
Date Sampled:
Date Received:
Contact: Date Tested:
Site Address: Sampled By:
Testing carried out at i2 Analytical Limited, ul. Pionierow 39, 41-711 Ruda Slaska, Poland
Test Results:
Laboratory Reference: Depth Top [m]:
Hole No.: Depth Base [m]:
Sample Reference: Sample Type:
Soil Description:
Sample Preparation:
Legend, based on BS 5930:2015 Code of practice for site investigations
Plasticity Liquid Limit
C Clay L Low below 35
M Silt I Medium 35 to 50
H High 50 to 70
V Very high 70 to 90
E Extremely high exceeding 90
Organic O append to classification for organic material ( eg CHO )
Note: Moisture Content by BS 1377-2: 1990: Clause 3.2
Remarks:
Signed:
for and on behalf of i2 Analytical Ltd
Opinions and interpretations expressed herein are outside of the scope of the UKAS Accreditation. This
report may not be reproduced other than in full without the prior written approval of the issuing
laboratory. The results included within the report are representative of the samples submitted for
analysis.Page 1 of 1 Date Reported: 30/04/2020 GF 232.8
30 90 38 52 100
Tested in natural condition
As Received Moisture
Content [%]
Liquid Limit
[%]
Plastic Limit
[%]
Plasticity Index
[%]
% Passing 425µm
BS Test Sieve
BH3 Not Given
Not Given D
Brown CLAY
Matthew Somerville 20/04/2020
Hestur Kings Parade Cliff Slip Not Given
1494822 10.00
Endeavour Drilling J4280
Unit 7 Mapledean Industrial Estate, Maldon Road,
Chelmsford, CM3 6LD
20-96643
03/04/2020
16/04/2020
CL
CI
CH
CV
CE
MLMI
MH
MV
ME
A line
0
10
20
30
40
50
60
70
80
90
100
0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150
PLA
STIC
ITY
IN
DEX
LIQUID LIMIT
Szczepan BielatowiczPL Deputy of Head of Geotechnical Section
TEST CERTIFICATE
Liquid and Plastic Limits
Tested in Accordance with: BS 1377-2: 1990: Clause 4.4 and 5
Client: Client Reference:
Client Address: Job Number:
Date Sampled:
Date Received:
Contact: Date Tested:
Site Address: Sampled By:
Testing carried out at i2 Analytical Limited, ul. Pionierow 39, 41-711 Ruda Slaska, Poland
Test Results:
Laboratory Reference: Depth Top [m]:
Hole No.: Depth Base [m]:
Sample Reference: Sample Type:
Soil Description:
Sample Preparation:
Legend, based on BS 5930:2015 Code of practice for site investigations
Plasticity Liquid Limit
C Clay L Low below 35
M Silt I Medium 35 to 50
H High 50 to 70
V Very high 70 to 90
E Extremely high exceeding 90
Organic O append to classification for organic material ( eg CHO )
Note: Moisture Content by BS 1377-2: 1990: Clause 3.2
Remarks:
Signed:
for and on behalf of i2 Analytical Ltd
Opinions and interpretations expressed herein are outside of the scope of the UKAS Accreditation. This
report may not be reproduced other than in full without the prior written approval of the issuing
laboratory. The results included within the report are representative of the samples submitted for
analysis.Page 1 of 1 Date Reported: 30/04/2020 GF 232.8
29 91 35 56 100
Tested in natural condition
As Received Moisture
Content [%]
Liquid Limit
[%]
Plastic Limit
[%]
Plasticity Index
[%]
% Passing 425µm
BS Test Sieve
BH3 Not Given
Not Given D
Brown CLAY
Matthew Somerville 20/04/2020
Hestur Kings Parade Cliff Slip Not Given
1494824 12.00
Endeavour Drilling J4280
Unit 7 Mapledean Industrial Estate, Maldon Road,
Chelmsford, CM3 6LD
20-96643
03/04/2020
16/04/2020
CL
CI
CH
CV
CE
MLMI
MH
MV
ME
A line
0
10
20
30
40
50
60
70
80
90
100
0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150
PLA
STIC
ITY
IN
DEX
LIQUID LIMIT
Szczepan BielatowiczPL Deputy of Head of Geotechnical Section
TEST CERTIFICATE
Liquid and Plastic Limits
Tested in Accordance with: BS 1377-2: 1990: Clause 4.4 and 5
Client: Client Reference:
Client Address: Job Number:
Date Sampled:
Date Received:
Contact: Date Tested:
Site Address: Sampled By:
Testing carried out at i2 Analytical Limited, ul. Pionierow 39, 41-711 Ruda Slaska, Poland
Test Results:
Laboratory Reference: Depth Top [m]:
Hole No.: Depth Base [m]:
Sample Reference: Sample Type:
Soil Description:
Sample Preparation:
Legend, based on BS 5930:2015 Code of practice for site investigations
Plasticity Liquid Limit
C Clay L Low below 35
M Silt I Medium 35 to 50
H High 50 to 70
V Very high 70 to 90
E Extremely high exceeding 90
Organic O append to classification for organic material ( eg CHO )
Note: Moisture Content by BS 1377-2: 1990: Clause 3.2
Remarks:
Signed:
for and on behalf of i2 Analytical Ltd
Opinions and interpretations expressed herein are outside of the scope of the UKAS Accreditation. This
report may not be reproduced other than in full without the prior written approval of the issuing
laboratory. The results included within the report are representative of the samples submitted for
analysis.Page 1 of 1 Date Reported: 30/04/2020 GF 232.8
29 82 32 50 100
Tested in natural condition
As Received Moisture
Content [%]
Liquid Limit
[%]
Plastic Limit
[%]
Plasticity Index
[%]
% Passing 425µm
BS Test Sieve
BH3 Not Given
Not Given D
Brown CLAY
Matthew Somerville 20/04/2020
Hestur Kings Parade Cliff Slip Not Given
1494826 16.00
Endeavour Drilling J4280
Unit 7 Mapledean Industrial Estate, Maldon Road,
Chelmsford, CM3 6LD
20-96643
03/04/2020
16/04/2020
CL
CI
CH
CV
CE
MLMI
MH
MV
ME
A line
0
10
20
30
40
50
60
70
80
90
100
0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150
PLA
STIC
ITY
IN
DEX
LIQUID LIMIT
Szczepan BielatowiczPL Deputy of Head of Geotechnical Section
TEST CERTIFICATE
Liquid and Plastic Limits
Tested in Accordance with: BS 1377-2: 1990: Clause 4.4 and 5
Client: Client Reference:
Client Address: Job Number:
Date Sampled:
Date Received:
Contact: Date Tested:
Site Address: Sampled By:
Testing carried out at i2 Analytical Limited, ul. Pionierow 39, 41-711 Ruda Slaska, Poland
Test Results:
Laboratory Reference: Depth Top [m]:
Hole No.: Depth Base [m]:
Sample Reference: Sample Type:
Soil Description:
Sample Preparation:
Legend, based on BS 5930:2015 Code of practice for site investigations
Plasticity Liquid Limit
C Clay L Low below 35
M Silt I Medium 35 to 50
H High 50 to 70
V Very high 70 to 90
E Extremely high exceeding 90
Organic O append to classification for organic material ( eg CHO )
Note: Moisture Content by BS 1377-2: 1990: Clause 3.2
Remarks:
Signed:
for and on behalf of i2 Analytical Ltd
Opinions and interpretations expressed herein are outside of the scope of the UKAS Accreditation. This
report may not be reproduced other than in full without the prior written approval of the issuing
laboratory. The results included within the report are representative of the samples submitted for
analysis.Page 1 of 1 Date Reported: 30/04/2020 GF 232.8
29 89 34 55 100
Tested in natural condition
As Received Moisture
Content [%]
Liquid Limit
[%]
Plastic Limit
[%]
Plasticity Index
[%]
% Passing 425µm
BS Test Sieve
BH3 Not Given
Not Given D
Brown CLAY
Matthew Somerville 20/04/2020
Hestur Kings Parade Cliff Slip Not Given
1494828 19.00
Endeavour Drilling J4280
Unit 7 Mapledean Industrial Estate, Maldon Road,
Chelmsford, CM3 6LD
20-96643
03/04/2020
16/04/2020
CL
CI
CH
CV
CE
MLMI
MH
MV
ME
A line
0
10
20
30
40
50
60
70
80
90
100
0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150
PLA
STIC
ITY
IN
DEX
LIQUID LIMIT
Szczepan BielatowiczPL Deputy of Head of Geotechnical Section
TEST CERTIFICATE
Liquid and Plastic Limits
Tested in Accordance with: BS 1377-2: 1990: Clause 4.4 and 5
Client: Client Reference:
Client Address: Job Number:
Date Sampled:
Date Received:
Contact: Date Tested:
Site Address: Sampled By:
Testing carried out at i2 Analytical Limited, ul. Pionierow 39, 41-711 Ruda Slaska, Poland
Test Results:
Laboratory Reference: Depth Top [m]:
Hole No.: Depth Base [m]:
Sample Reference: Sample Type:
Soil Description:
Sample Preparation:
Legend, based on BS 5930:2015 Code of practice for site investigations
Plasticity Liquid Limit
C Clay L Low below 35
M Silt I Medium 35 to 50
H High 50 to 70
V Very high 70 to 90
E Extremely high exceeding 90
Organic O append to classification for organic material ( eg CHO )
Note: Moisture Content by BS 1377-2: 1990: Clause 3.2
Remarks:
Signed:
for and on behalf of i2 Analytical Ltd
Opinions and interpretations expressed herein are outside of the scope of the UKAS Accreditation. This
report may not be reproduced other than in full without the prior written approval of the issuing
laboratory. The results included within the report are representative of the samples submitted for
analysis.Page 1 of 1 Date Reported: 30/04/2020 GF 232.8
27 75 25 50 63
Tested after washing to remove >425um
As Received Moisture
Content [%]
Liquid Limit
[%]
Plastic Limit
[%]
Plasticity Index
[%]
% Passing 425µm
BS Test Sieve
BH4 Not Given
Not Given D
Greyish brown gravelly CLAY
Matthew Somerville 20/04/2020
Hestur Kings Parade Cliff Slip Not Given
1494830 1.20
Endeavour Drilling J4280
Unit 7 Mapledean Industrial Estate, Maldon Road,
Chelmsford, CM3 6LD
20-96643
06/04/2020
16/04/2020
CL
CI
CH
CV
CE
MLMI
MH
MV
ME
A line
0
10
20
30
40
50
60
70
80
90
100
0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150
PLA
STIC
ITY
IN
DEX
LIQUID LIMIT
Szczepan BielatowiczPL Deputy of Head of Geotechnical Section
TEST CERTIFICATE
Liquid and Plastic Limits
Tested in Accordance with: BS 1377-2: 1990: Clause 4.4 and 5
Client: Client Reference:
Client Address: Job Number:
Date Sampled:
Date Received:
Contact: Date Tested:
Site Address: Sampled By:
Testing carried out at i2 Analytical Limited, ul. Pionierow 39, 41-711 Ruda Slaska, Poland
Test Results:
Laboratory Reference: Depth Top [m]:
Hole No.: Depth Base [m]:
Sample Reference: Sample Type:
Soil Description:
Sample Preparation:
Legend, based on BS 5930:2015 Code of practice for site investigations
Plasticity Liquid Limit
C Clay L Low below 35
M Silt I Medium 35 to 50
H High 50 to 70
V Very high 70 to 90
E Extremely high exceeding 90
Organic O append to classification for organic material ( eg CHO )
Note: Moisture Content by BS 1377-2: 1990: Clause 3.2
Remarks:
Signed:
for and on behalf of i2 Analytical Ltd
Opinions and interpretations expressed herein are outside of the scope of the UKAS Accreditation. This
report may not be reproduced other than in full without the prior written approval of the issuing
laboratory. The results included within the report are representative of the samples submitted for
analysis.Page 1 of 1 Date Reported: 30/04/2020 GF 232.8
35 88 35 53 100
Tested in natural condition
As Received Moisture
Content [%]
Liquid Limit
[%]
Plastic Limit
[%]
Plasticity Index
[%]
% Passing 425µm
BS Test Sieve
BH4 Not Given
Not Given D
Brown CLAY
Matthew Somerville 20/04/2020
Hestur Kings Parade Cliff Slip Not Given
1494832 3.00
Endeavour Drilling J4280
Unit 7 Mapledean Industrial Estate, Maldon Road,
Chelmsford, CM3 6LD
20-96643
06/04/2020
16/04/2020
CL
CI
CH
CV
CE
MLMI
MH
MV
ME
A line
0
10
20
30
40
50
60
70
80
90
100
0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150
PLA
STIC
ITY
IN
DEX
LIQUID LIMIT
Szczepan BielatowiczPL Deputy of Head of Geotechnical Section
TEST CERTIFICATE
Liquid and Plastic Limits
Tested in Accordance with: BS 1377-2: 1990: Clause 4.4 and 5
Client: Client Reference:
Client Address: Job Number:
Date Sampled:
Date Received:
Contact: Date Tested:
Site Address: Sampled By:
Testing carried out at i2 Analytical Limited, ul. Pionierow 39, 41-711 Ruda Slaska, Poland
Test Results:
Laboratory Reference: Depth Top [m]:
Hole No.: Depth Base [m]:
Sample Reference: Sample Type:
Soil Description:
Sample Preparation:
Legend, based on BS 5930:2015 Code of practice for site investigations
Plasticity Liquid Limit
C Clay L Low below 35
M Silt I Medium 35 to 50
H High 50 to 70
V Very high 70 to 90
E Extremely high exceeding 90
Organic O append to classification for organic material ( eg CHO )
Note: Moisture Content by BS 1377-2: 1990: Clause 3.2
Remarks:
Signed:
for and on behalf of i2 Analytical Ltd
Opinions and interpretations expressed herein are outside of the scope of the UKAS Accreditation. This
report may not be reproduced other than in full without the prior written approval of the issuing
laboratory. The results included within the report are representative of the samples submitted for
analysis.Page 1 of 1 Date Reported: 30/04/2020 GF 232.8
27 79 34 45 100
Tested in natural condition
As Received Moisture
Content [%]
Liquid Limit
[%]
Plastic Limit
[%]
Plasticity Index
[%]
% Passing 425µm
BS Test Sieve
BH4 Not Given
Not Given D
Brown CLAY
Matthew Somerville 20/04/2020
Hestur Kings Parade Cliff Slip Not Given
1494834 7.00
Endeavour Drilling J4280
Unit 7 Mapledean Industrial Estate, Maldon Road,
Chelmsford, CM3 6LD
20-96643
06/04/2020
16/04/2020
CL
CI
CH
CV
CE
MLMI
MH
MV
ME
A line
0
10
20
30
40
50
60
70
80
90
100
0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150
PLA
STIC
ITY
IN
DEX
LIQUID LIMIT
Szczepan BielatowiczPL Deputy of Head of Geotechnical Section
TEST CERTIFICATE
Liquid and Plastic Limits
Tested in Accordance with: BS 1377-2: 1990: Clause 4.4 and 5
Client: Client Reference:
Client Address: Job Number:
Date Sampled:
Date Received:
Contact: Date Tested:
Site Address: Sampled By:
Testing carried out at i2 Analytical Limited, ul. Pionierow 39, 41-711 Ruda Slaska, Poland
Test Results:
Laboratory Reference: Depth Top [m]:
Hole No.: Depth Base [m]:
Sample Reference: Sample Type:
Soil Description:
Sample Preparation:
Legend, based on BS 5930:2015 Code of practice for site investigations
Plasticity Liquid Limit
C Clay L Low below 35
M Silt I Medium 35 to 50
H High 50 to 70
V Very high 70 to 90
E Extremely high exceeding 90
Organic O append to classification for organic material ( eg CHO )
Note: Moisture Content by BS 1377-2: 1990: Clause 3.2
Remarks:
Signed:
for and on behalf of i2 Analytical Ltd
Opinions and interpretations expressed herein are outside of the scope of the UKAS Accreditation. This
report may not be reproduced other than in full without the prior written approval of the issuing
laboratory. The results included within the report are representative of the samples submitted for
analysis.Page 1 of 1 Date Reported: 30/04/2020 GF 232.8
30 78 39 39 100
Tested in natural condition
As Received Moisture
Content [%]
Liquid Limit
[%]
Plastic Limit
[%]
Plasticity Index
[%]
% Passing 425µm
BS Test Sieve
BH4 Not Given
Not Given D
Brown CLAY
Matthew Somerville 20/04/2020
Hestur Kings Parade Cliff Slip Not Given
1494836 9.00
Endeavour Drilling J4280
Unit 7 Mapledean Industrial Estate, Maldon Road,
Chelmsford, CM3 6LD
20-96643
06/04/2020
16/04/2020
CL
CI
CH
CV
CE
MLMI
MH
MV
ME
A line
0
10
20
30
40
50
60
70
80
90
100
0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150
PLA
STIC
ITY
IN
DEX
LIQUID LIMIT
Szczepan BielatowiczPL Deputy of Head of Geotechnical Section
TEST CERTIFICATE
Liquid and Plastic Limits
Tested in Accordance with: BS 1377-2: 1990: Clause 4.4 and 5
Client: Client Reference:
Client Address: Job Number:
Date Sampled:
Date Received:
Contact: Date Tested:
Site Address: Sampled By:
Testing carried out at i2 Analytical Limited, ul. Pionierow 39, 41-711 Ruda Slaska, Poland
Test Results:
Laboratory Reference: Depth Top [m]:
Hole No.: Depth Base [m]:
Sample Reference: Sample Type:
Soil Description:
Sample Preparation:
Legend, based on BS 5930:2015 Code of practice for site investigations
Plasticity Liquid Limit
C Clay L Low below 35
M Silt I Medium 35 to 50
H High 50 to 70
V Very high 70 to 90
E Extremely high exceeding 90
Organic O append to classification for organic material ( eg CHO )
Note: Moisture Content by BS 1377-2: 1990: Clause 3.2
Remarks:
Signed:
for and on behalf of i2 Analytical Ltd
Opinions and interpretations expressed herein are outside of the scope of the UKAS Accreditation. This
report may not be reproduced other than in full without the prior written approval of the issuing
laboratory. The results included within the report are representative of the samples submitted for
analysis.Page 1 of 1 Date Reported: 30/04/2020 GF 232.8
34 96 30 66 100
Tested in natural condition
As Received Moisture
Content [%]
Liquid Limit
[%]
Plastic Limit
[%]
Plasticity Index
[%]
% Passing 425µm
BS Test Sieve
BH6 Not Given
Not Given D
Brown CLAY
Matthew Somerville 20/04/2020
Hestur Kings Parade Cliff Slip Not Given
1494838 3.00
Endeavour Drilling J4280
Unit 7 Mapledean Industrial Estate, Maldon Road,
Chelmsford, CM3 6LD
20-96643
07/04/2020
16/04/2020
CL
CI
CH
CV
CE
MLMI
MH
MV
ME
A line
0
10
20
30
40
50
60
70
80
90
100
0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150
PLA
STIC
ITY
IN
DEX
LIQUID LIMIT
Szczepan BielatowiczPL Deputy of Head of Geotechnical Section
TEST CERTIFICATE
Liquid and Plastic Limits
Tested in Accordance with: BS 1377-2: 1990: Clause 4.4 and 5
Client: Client Reference:
Client Address: Job Number:
Date Sampled:
Date Received:
Contact: Date Tested:
Site Address: Sampled By:
Testing carried out at i2 Analytical Limited, ul. Pionierow 39, 41-711 Ruda Slaska, Poland
Test Results:
Laboratory Reference: Depth Top [m]:
Hole No.: Depth Base [m]:
Sample Reference: Sample Type:
Soil Description:
Sample Preparation:
Legend, based on BS 5930:2015 Code of practice for site investigations
Plasticity Liquid Limit
C Clay L Low below 35
M Silt I Medium 35 to 50
H High 50 to 70
V Very high 70 to 90
E Extremely high exceeding 90
Organic O append to classification for organic material ( eg CHO )
Note: Moisture Content by BS 1377-2: 1990: Clause 3.2
Remarks:
Signed:
for and on behalf of i2 Analytical Ltd
Opinions and interpretations expressed herein are outside of the scope of the UKAS Accreditation. This
report may not be reproduced other than in full without the prior written approval of the issuing
laboratory. The results included within the report are representative of the samples submitted for
analysis.Page 1 of 1 Date Reported: 30/04/2020 GF 232.8
32 87 34 53 100
Tested in natural condition
As Received Moisture
Content [%]
Liquid Limit
[%]
Plastic Limit
[%]
Plasticity Index
[%]
% Passing 425µm
BS Test Sieve
BH6 Not Given
Not Given D
Brown CLAY
Matthew Somerville 20/04/2020
Hestur Kings Parade Cliff Slip Not Given
1494840 5.00
Endeavour Drilling J4280
Unit 7 Mapledean Industrial Estate, Maldon Road,
Chelmsford, CM3 6LD
20-96643
07/04/2020
16/04/2020
CL
CI
CH
CV
CE
MLMI
MH
MV
ME
A line
0
10
20
30
40
50
60
70
80
90
100
0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150
PLA
STIC
ITY
IN
DEX
LIQUID LIMIT
Szczepan BielatowiczPL Deputy of Head of Geotechnical Section
TEST CERTIFICATE
Liquid and Plastic Limits
Tested in Accordance with: BS 1377-2: 1990: Clause 4.4 and 5
Client: Client Reference:
Client Address: Job Number:
Date Sampled:
Date Received:
Contact: Date Tested:
Site Address: Sampled By:
Testing carried out at i2 Analytical Limited, ul. Pionierow 39, 41-711 Ruda Slaska, Poland
Test Results:
Laboratory Reference: Depth Top [m]:
Hole No.: Depth Base [m]:
Sample Reference: Sample Type:
Soil Description:
Sample Preparation:
Legend, based on BS 5930:2015 Code of practice for site investigations
Plasticity Liquid Limit
C Clay L Low below 35
M Silt I Medium 35 to 50
H High 50 to 70
V Very high 70 to 90
E Extremely high exceeding 90
Organic O append to classification for organic material ( eg CHO )
Note: Moisture Content by BS 1377-2: 1990: Clause 3.2
Remarks:
Signed:
for and on behalf of i2 Analytical Ltd
Opinions and interpretations expressed herein are outside of the scope of the UKAS Accreditation. This
report may not be reproduced other than in full without the prior written approval of the issuing
laboratory. The results included within the report are representative of the samples submitted for
analysis.Page 1 of 1 Date Reported: 30/04/2020 GF 232.8
29 81 30 51 100
Tested in natural condition
As Received Moisture
Content [%]
Liquid Limit
[%]
Plastic Limit
[%]
Plasticity Index
[%]
% Passing 425µm
BS Test Sieve
BH6 Not Given
Not Given D
Brown CLAY
Matthew Somerville 20/04/2020
Hestur Kings Parade Cliff Slip Not Given
1494841 7.00
Endeavour Drilling J4280
Unit 7 Mapledean Industrial Estate, Maldon Road,
Chelmsford, CM3 6LD
20-96643
07/04/2020
16/04/2020
CL
CI
CH
CV
CE
MLMI
MH
MV
ME
A line
0
10
20
30
40
50
60
70
80
90
100
0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150
PLA
STIC
ITY
IN
DEX
LIQUID LIMIT
Szczepan BielatowiczPL Deputy of Head of Geotechnical Section
TEST CERTIFICATE
Liquid and Plastic Limits
Tested in Accordance with: BS 1377-2: 1990: Clause 4.4 and 5
Client: Client Reference:
Client Address: Job Number:
Date Sampled:
Date Received:
Contact: Date Tested:
Site Address: Sampled By:
Testing carried out at i2 Analytical Limited, ul. Pionierow 39, 41-711 Ruda Slaska, Poland
Test Results:
Laboratory Reference: Depth Top [m]:
Hole No.: Depth Base [m]:
Sample Reference: Sample Type:
Soil Description:
Sample Preparation:
Legend, based on BS 5930:2015 Code of practice for site investigations
Plasticity Liquid Limit
C Clay L Low below 35
M Silt I Medium 35 to 50
H High 50 to 70
V Very high 70 to 90
E Extremely high exceeding 90
Organic O append to classification for organic material ( eg CHO )
Note: Moisture Content by BS 1377-2: 1990: Clause 3.2
Remarks:
Signed:
for and on behalf of i2 Analytical Ltd
Opinions and interpretations expressed herein are outside of the scope of the UKAS Accreditation. This
report may not be reproduced other than in full without the prior written approval of the issuing
laboratory. The results included within the report are representative of the samples submitted for
analysis.Page 1 of 1 Date Reported: 30/04/2020 GF 232.8
26 79 36 43 100
Tested in natural condition
As Received Moisture
Content [%]
Liquid Limit
[%]
Plastic Limit
[%]
Plasticity Index
[%]
% Passing 425µm
BS Test Sieve
BH6 Not Given
Not Given D
Brown CLAY
Matthew Somerville 20/04/2020
Hestur Kings Parade Cliff Slip Not Given
1494843 9.00
Endeavour Drilling J4280
Unit 7 Mapledean Industrial Estate, Maldon Road,
Chelmsford, CM3 6LD
20-96643
07/04/2020
16/04/2020
CL
CI
CH
CV
CE
MLMI
MH
MV
ME
A line
0
10
20
30
40
50
60
70
80
90
100
0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150
PLA
STIC
ITY
IN
DEX
LIQUID LIMIT
Szczepan BielatowiczPL Deputy of Head of Geotechnical Section
SUMMARY REPORT
Summary of Classification Test Results
Tested in Accordance with:
Client: Client Reference:
Client Address: Job Number:
Date Sampled:
Date Received:
Contact: Date Tested:
Site Address: Sampled By:
Testing carried out at i2 Analytical Limited, ul. Pionierow 39, 41-711 Ruda Slaska, Poland
Test results
m m % % % % % % Mg/m3 Mg/m3 Mg/m3 %
7.00Not
GivenD 31 100 89 34 55
9.00Not
GivenD 29 100 95 32 63
11.00Not
GivenD 30 100 96 37 59
13.00Not
GivenD 30 100 87 37 50
16.00Not
GivenD 29 100 83 32 51
19.00Not
GivenB 30 100 98 39 59
6.00Not
GivenD 32 100 87 38 49
8.00Not
GivenD 30 100 92 33 59
10.00Not
GivenD 30 100 90 38 52
12.00Not
GivenD 29 100 91 35 56
Note: # Non accredited; NP - Non plastic
Comments:
Signed:
for and on behalf of i2 Analytical LtdOpinions and interpretations expressed herein are outside of the scope of the UKAS Accreditation. This report may not be reproduced other than in full without the prior written
approval of the issuing laboratory. The results included within the report are representative of the samples submitted for analysis.
Page 1 of 1 Date Reported: 30/04/2020 GF 234.10
1494822 BH3 Not Given Brown CLAY Atterberg 1 Point
1494824 BH3 Not Given Brown CLAY Atterberg 1 Point
1494819 BH3 Not Given Brown CLAY Atterberg 1 Point
1494821 BH3 Not Given Brown CLAY Atterberg 1 Point
1494815 BH1 Not Given Brown CLAY Atterberg 1 Point
1494817 BH1 Not Given Brown CLAY Atterberg 1 Point
1494812 BH1 Not Given Brown CLAY Atterberg 1 Point
1494813 BH1 Not Given Brown CLAY Atterberg 1 Point
1494808 BH1 Not Given Brown CLAY Atterberg 1 Point
1494810 BH1 Not Given Brown CLAY Atterberg 1 Point
Reference
Depth
Top
Depth
BaseType
%
Passing
425um
LL PL
Density
Tota
l
Po
rosi
ty#
PI bulk dry PDLaboratory
Reference
Hole
No.
Sample
Description RemarksMC WC
Atterberg
Endeavour Drilling MC by BS 1377-2: 1990: Clause 3.2; WC by BS EN 17892-1: 2014; Atterberg
by BS 1377-2: 1990: Clause 4.3, Clause 4.4 and 5; PD by BS 1377-2: 1990:
Clause 8.2
J4280
Unit 7 Mapledean Industrial Estate, Maldon
Road,
Chelmsford, CM3 6LD
20-96643
01/04 - 03/04/2020
16/04/2020
Matthew Somerville 20/04/2020
Hestur Kings Parade Cliff Slip Not Given
Szczepan BielatowiczPL Deputy of Head of Geotechnical Section
SUMMARY REPORT
Summary of Classification Test Results
Tested in Accordance with:
Client: Client Reference:
Client Address: Job Number:
Date Sampled:
Date Received:
Contact: Date Tested:
Site Address: Sampled By:
Testing carried out at i2 Analytical Limited, ul. Pionierow 39, 41-711 Ruda Slaska, Poland
Test results
m m % % % % % % Mg/m3 Mg/m3 Mg/m3 %
16.00Not
GivenD 29 100 82 32 50
19.00Not
GivenD 29 100 89 34 55
1.20Not
GivenD 27 63 75 25 50
3.00Not
GivenD 35 100 88 35 53
7.00Not
GivenD 27 100 79 34 45
9.00Not
GivenD 30 100 78 39 39
3.00Not
GivenD 34 100 96 30 66
5.00Not
GivenD 32 100 87 34 53
7.00Not
GivenD 29 100 81 30 51
9.00Not
GivenD 26 100 79 36 43
Note: # Non accredited; NP - Non plastic
Comments:
Signed:
for and on behalf of i2 Analytical LtdOpinions and interpretations expressed herein are outside of the scope of the UKAS Accreditation. This report may not be reproduced other than in full without the prior written
approval of the issuing laboratory. The results included within the report are representative of the samples submitted for analysis.
Page 1 of 1 Date Reported: 30/04/2020 GF 234.10
1494841 BH6 Not Given Brown CLAY Atterberg 1 Point
1494843 BH6 Not Given Brown CLAY Atterberg 1 Point
1494838 BH6 Not Given Brown CLAY Atterberg 1 Point
1494840 BH6 Not Given Brown CLAY Atterberg 1 Point
1494834 BH4 Not Given Brown CLAY Atterberg 1 Point
1494836 BH4 Not Given Brown CLAY Atterberg 1 Point
1494830 BH4 Not Given Greyish brown gravelly CLAY Atterberg 1 Point
1494832 BH4 Not Given Brown CLAY Atterberg 1 Point
1494826 BH3 Not Given Brown CLAY Atterberg 1 Point
1494828 BH3 Not Given Brown CLAY Atterberg 1 Point
Reference
Depth
Top
Depth
BaseType
%
Passing
425um
LL PL
Density
Tota
l
Po
rosi
ty#
PI bulk dry PDLaboratory
Reference
Hole
No.
Sample
Description RemarksMC WC
Atterberg
Endeavour Drilling MC by BS 1377-2: 1990: Clause 3.2; WC by BS EN 17892-1: 2014; Atterberg
by BS 1377-2: 1990: Clause 4.3, Clause 4.4 and 5; PD by BS 1377-2: 1990:
Clause 8.2
J4280
Unit 7 Mapledean Industrial Estate, Maldon
Road,
Chelmsford, CM3 6LD
20-96643
03/04 - 07/04/2020
16/04/2020
Matthew Somerville 20/04/2020
Hestur Kings Parade Cliff Slip Not Given
Szczepan BielatowiczPL Deputy of Head of Geotechnical Section
TEST CERTIFICATEUnconsolidated Undrained
Triaxial Compression
Tested in Accordance with:
BS 1377-7: 1990: Clause 8
Client: Client Reference:
Client Address: Job Number:
Date Sampled:
Date Received:
Contact: Date Tested:
Site Address: Sampled By:
Testing carried out at i2 Analytical Limited, ul. Pionierow 39, 41-711 Ruda Slaska, Poland
Test Results:
Laboratory Reference: Depth Top [m]:
Hole No.: Depth Base [m]:
Sample Reference: Sample Type:
Sample Description:
Test Number Rate of Strain %/min
Length mm Cell Pressure kPa
Diameter mm Axial Strain at failure %
Bulk Density Mg/m3 Deviator Stress, ( σ1 - σ3 )f kPa
Moisture Content % Undrained Shear Strength, cu kPa ½( σ1 - σ3 )f
Dry Density Mg/m3 Mode of Failure
Membrane Correction kPa Membrane thickness mm
Position within sample
Remarks:
Signed:
for and on behalf of i2 Analytical Ltd
Endeavour Drilling J4280
Unit 7 Mapledean Industrial Estate, Maldon Road,
Chelmsford, CM3 6LD
20-96643
01/04/2020
16/04/2020
Matthew Somerville 24/04/2020
Hestur Kings Parade Cliff Slip Not Given
1494809 7.50
BH1 7.95
Not Given U
Brown CLAY
1 2.00
75.32 150
37.24 5.9
1.98 293
28 147
1.55 Compound
0.71 0.17
Note: Deviator stress corrected for area change and membrane effects. Mohr circles and their interpretation is not covered by BS1377.
This is provided for information only.
Opinions and interpretations expressed herein are outside of the scope of the UKAS Accreditation. This
report may not be reproduced other than in full without the prior written approval of the issuing
laboratory. The results included within the report are representative of the samples submitted for
analysis.Page 1 of 1 Date Reported: 30/04/2020 GF 184.10
0
50
100
150
200
250
300
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25
Corr
ecte
d D
evia
tor
Str
ess kP
a
Axial Strain %
Deviator Stress v Axial Strain
0
50
100
150
200
250
300
0 50 100 150 200 250 300 350 400 450 500 550 600
Shear
Str
ength
kP
a
Normal Stresses kPa
Mohr Circles
Szczepan BielatowiczPL Deputy of Head of Geotechnical Section
TEST CERTIFICATEUnconsolidated Undrained
Triaxial Compression
Tested in Accordance with:
BS 1377-7: 1990: Clause 8
Client: Client Reference:
Client Address: Job Number:
Date Sampled:
Date Received:
Contact: Date Tested:
Site Address: Sampled By:
Testing carried out at i2 Analytical Limited, ul. Pionierow 39, 41-711 Ruda Slaska, Poland
Test Results:
Laboratory Reference: Depth Top [m]:
Hole No.: Depth Base [m]:
Sample Reference: Sample Type:
Sample Description:
Test Number Rate of Strain %/min
Length mm Cell Pressure kPa
Diameter mm Axial Strain at failure %
Bulk Density Mg/m3 Deviator Stress, ( σ1 - σ3 )f kPa
Moisture Content % Undrained Shear Strength, cu kPa ½( σ1 - σ3 )f
Dry Density Mg/m3 Mode of Failure
Membrane Correction kPa Membrane thickness mm
Position within sample
Remarks:
Signed:
for and on behalf of i2 Analytical Ltd
Endeavour Drilling J4280
Unit 7 Mapledean Industrial Estate, Maldon Road,
Chelmsford, CM3 6LD
20-96643
01/04/2020
16/04/2020
Matthew Somerville 24/04/2020
Hestur Kings Parade Cliff Slip Not Given
1494811 10.50
BH1 10.95
Not Given U
Brown CLAY
1 2.00
75.10 210
37.16 2.4
1.92 287
29 143
1.49 Brittle
0.34 0.19
Note: Deviator stress corrected for area change and membrane effects. Mohr circles and their interpretation is not covered by BS1377.
This is provided for information only.
Opinions and interpretations expressed herein are outside of the scope of the UKAS Accreditation. This
report may not be reproduced other than in full without the prior written approval of the issuing
laboratory. The results included within the report are representative of the samples submitted for
analysis.Page 1 of 1 Date Reported: 30/04/2020 GF 184.10
0
50
100
150
200
250
300
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25
Corr
ecte
d D
evia
tor
Str
ess kP
a
Axial Strain %
Deviator Stress v Axial Strain
0
50
100
150
200
250
300
0 50 100 150 200 250 300 350 400 450 500 550 600
Shear
Str
ength
kP
a
Normal Stresses kPa
Mohr Circles
Szczepan BielatowiczPL Deputy of Head of Geotechnical Section
TEST CERTIFICATEUnconsolidated Undrained
Triaxial Compression
Tested in Accordance with:
BS 1377-7: 1990: Clause 8
Client: Client Reference:
Client Address: Job Number:
Date Sampled:
Date Received:
Contact: Date Tested:
Site Address: Sampled By:
Testing carried out at i2 Analytical Limited, ul. Pionierow 39, 41-711 Ruda Slaska, Poland
Test Results:
Laboratory Reference: Depth Top [m]:
Hole No.: Depth Base [m]:
Sample Reference: Sample Type:
Sample Description:
Test Number Rate of Strain %/min
Length mm Cell Pressure kPa
Diameter mm Axial Strain at failure %
Bulk Density Mg/m3 Deviator Stress, ( σ1 - σ3 )f kPa
Moisture Content % Undrained Shear Strength, cu kPa ½( σ1 - σ3 )f
Dry Density Mg/m3 Mode of Failure
Membrane Correction kPa Membrane thickness mm
Position within sample
Remarks:
Signed:
for and on behalf of i2 Analytical Ltd
Endeavour Drilling J4280
Unit 7 Mapledean Industrial Estate, Maldon Road,
Chelmsford, CM3 6LD
20-96643
01/04/2020
16/04/2020
Matthew Somerville 24/04/2020
Hestur Kings Parade Cliff Slip Not Given
1494814 13.50
BH1 13.95
Not Given U
Brown CLAY
1 2.00
74.89 270
37.00 6.9
1.97 381
32 191
1.49 Brittle
0.93 0.20
Note: Deviator stress corrected for area change and membrane effects. Mohr circles and their interpretation is not covered by BS1377.
This is provided for information only.
Opinions and interpretations expressed herein are outside of the scope of the UKAS Accreditation. This
report may not be reproduced other than in full without the prior written approval of the issuing
laboratory. The results included within the report are representative of the samples submitted for
analysis.Page 1 of 1 Date Reported: 30/04/2020 GF 184.10
0
100
200
300
400
500
600
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25
Corr
ecte
d D
evia
tor
Str
ess kP
a
Axial Strain %
Deviator Stress v Axial Strain
0
100
200
300
400
500
600
0 100 200 300 400 500 600 700 800 900 1000 1100 1200
Shear
Str
ength
kP
a
Normal Stresses kPa
Mohr Circles
Szczepan BielatowiczPL Deputy of Head of Geotechnical Section
TEST CERTIFICATEUnconsolidated Undrained
Triaxial Compression
Tested in Accordance with:
BS 1377-7: 1990: Clause 8
Client: Client Reference:
Client Address: Job Number:
Date Sampled:
Date Received:
Contact: Date Tested:
Site Address: Sampled By:
Testing carried out at i2 Analytical Limited, ul. Pionierow 39, 41-711 Ruda Slaska, Poland
Test Results:
Laboratory Reference: Depth Top [m]:
Hole No.: Depth Base [m]:
Sample Reference: Sample Type:
Sample Description:
Test Number Rate of Strain %/min
Length mm Cell Pressure kPa
Diameter mm Axial Strain at failure %
Bulk Density Mg/m3 Deviator Stress, ( σ1 - σ3 )f kPa
Moisture Content % Undrained Shear Strength, cu kPa ½( σ1 - σ3 )f
Dry Density Mg/m3 Mode of Failure
Membrane Correction kPa Membrane thickness mm
Position within sample
Remarks:
Signed:
for and on behalf of i2 Analytical Ltd
Endeavour Drilling J4280
Unit 7 Mapledean Industrial Estate, Maldon Road,
Chelmsford, CM3 6LD
20-96643
01/04/2020
16/04/2020
Matthew Somerville 24/04/2020
Hestur Kings Parade Cliff Slip Not Given
1494816 16.50
BH1 16.95
Not Given U
Brown CLAY
1 2.00
74.62 330
37.40 5.6
1.95 359
30 180
1.49 Brittle
0.89 0.22
Note: Deviator stress corrected for area change and membrane effects. Mohr circles and their interpretation is not covered by BS1377.
This is provided for information only.
Opinions and interpretations expressed herein are outside of the scope of the UKAS Accreditation. This
report may not be reproduced other than in full without the prior written approval of the issuing
laboratory. The results included within the report are representative of the samples submitted for
analysis.Page 1 of 1 Date Reported: 30/04/2020 GF 184.10
0
100
200
300
400
500
600
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25
Corr
ecte
d D
evia
tor
Str
ess kP
a
Axial Strain %
Deviator Stress v Axial Strain
0
100
200
300
400
500
600
0 100 200 300 400 500 600 700 800 900 1000 1100 1200
Shear
Str
ength
kP
a
Normal Stresses kPa
Mohr Circles
Szczepan BielatowiczPL Deputy of Head of Geotechnical Section
TEST CERTIFICATEUnconsolidated Undrained
Triaxial Compression
Tested in Accordance with:
BS 1377-7: 1990: Clause 8
Client: Client Reference:
Client Address: Job Number:
Date Sampled:
Date Received:
Contact: Date Tested:
Site Address: Sampled By:
Testing carried out at i2 Analytical Limited, ul. Pionierow 39, 41-711 Ruda Slaska, Poland
Test Results:
Laboratory Reference: Depth Top [m]:
Hole No.: Depth Base [m]:
Sample Reference: Sample Type:
Sample Description:
Test Number Rate of Strain %/min
Length mm Cell Pressure kPa
Diameter mm Axial Strain at failure %
Bulk Density Mg/m3 Deviator Stress, ( σ1 - σ3 )f kPa
Moisture Content % Undrained Shear Strength, cu kPa ½( σ1 - σ3 )f
Dry Density Mg/m3 Mode of Failure
Membrane Correction kPa Membrane thickness mm
Position within sample
Remarks:
Signed:
for and on behalf of i2 Analytical Ltd
Endeavour Drilling J4280
Unit 7 Mapledean Industrial Estate, Maldon Road,
Chelmsford, CM3 6LD
20-96643
01/04/2020
16/04/2020
Matthew Somerville 24/04/2020
Hestur Kings Parade Cliff Slip Not Given
1494818 19.50
BH1 19.95
Not Given U
Brown CLAY
1 2.00
74.70 390
37.48 5.2
1.96 646
32 323
1.48 Compound
0.81 0.21
Note: Deviator stress corrected for area change and membrane effects. Mohr circles and their interpretation is not covered by BS1377.
This is provided for information only.
Opinions and interpretations expressed herein are outside of the scope of the UKAS Accreditation. This
report may not be reproduced other than in full without the prior written approval of the issuing
laboratory. The results included within the report are representative of the samples submitted for
analysis.Page 1 of 1 Date Reported: 30/04/2020 GF 184.10
0
200
400
600
800
1 000
1 200
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25
Corr
ecte
d D
evia
tor
Str
ess kP
a
Axial Strain %
Deviator Stress v Axial Strain
0
100
200
300
400
500
600
0 100 200 300 400 500 600 700 800 900 1000 1100 1200
Shear
Str
ength
kP
a
Normal Stresses kPa
Mohr Circles
Szczepan BielatowiczPL Deputy of Head of Geotechnical Section
TEST CERTIFICATEUnconsolidated Undrained
Triaxial Compression
Tested in Accordance with:
BS 1377-7: 1990: Clause 8
Client: Client Reference:
Client Address: Job Number:
Date Sampled:
Date Received:
Contact: Date Tested:
Site Address: Sampled By:
Testing carried out at i2 Analytical Limited, ul. Pionierow 39, 41-711 Ruda Slaska, Poland
Test Results:
Laboratory Reference: Depth Top [m]:
Hole No.: Depth Base [m]:
Sample Reference: Sample Type:
Sample Description:
Test Number Rate of Strain %/min
Length mm Cell Pressure kPa
Diameter mm Axial Strain at failure %
Bulk Density Mg/m3 Deviator Stress, ( σ1 - σ3 )f kPa
Moisture Content % Undrained Shear Strength, cu kPa ½( σ1 - σ3 )f
Dry Density Mg/m3 Mode of Failure
Membrane Correction kPa Membrane thickness mm
Position within sample
Remarks:
Signed:
for and on behalf of i2 Analytical Ltd
Endeavour Drilling J4280
Unit 7 Mapledean Industrial Estate, Maldon Road,
Chelmsford, CM3 6LD
20-96643
03/04/2020
16/04/2020
Matthew Somerville 24/04/2020
Hestur Kings Parade Cliff Slip Not Given
1494820 7.50
BH3 7.95
Not Given U
Brown CLAY
1 2.00
75.04 140
37.50 10.8
1.88 240
31 120
1.43 Brittle
1.13 0.18
Note: Deviator stress corrected for area change and membrane effects. Mohr circles and their interpretation is not covered by BS1377.
This is provided for information only.
Opinions and interpretations expressed herein are outside of the scope of the UKAS Accreditation. This
report may not be reproduced other than in full without the prior written approval of the issuing
laboratory. The results included within the report are representative of the samples submitted for
analysis.Page 1 of 1 Date Reported: 30/04/2020 GF 184.10
0
50
100
150
200
250
300
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25
Corr
ecte
d D
evia
tor
Str
ess kP
a
Axial Strain %
Deviator Stress v Axial Strain
0
50
100
150
200
250
300
0 50 100 150 200 250 300 350 400 450 500 550 600
Shear
Str
ength
kP
a
Normal Stresses kPa
Mohr Circles
Szczepan BielatowiczPL Deputy of Head of Geotechnical Section
TEST CERTIFICATEUnconsolidated Undrained
Triaxial Compression
Tested in Accordance with:
BS 1377-7: 1990: Clause 8
Client: Client Reference:
Client Address: Job Number:
Date Sampled:
Date Received:
Contact: Date Tested:
Site Address: Sampled By:
Testing carried out at i2 Analytical Limited, ul. Pionierow 39, 41-711 Ruda Slaska, Poland
Test Results:
Laboratory Reference: Depth Top [m]:
Hole No.: Depth Base [m]:
Sample Reference: Sample Type:
Sample Description:
Test Number Rate of Strain %/min
Length mm Cell Pressure kPa
Diameter mm Axial Strain at failure %
Bulk Density Mg/m3 Deviator Stress, ( σ1 - σ3 )f kPa
Moisture Content % Undrained Shear Strength, cu kPa ½( σ1 - σ3 )f
Dry Density Mg/m3 Mode of Failure
Membrane Correction kPa Membrane thickness mm
Position within sample
Remarks:
Signed:
for and on behalf of i2 Analytical Ltd
Endeavour Drilling J4280
Unit 7 Mapledean Industrial Estate, Maldon Road,
Chelmsford, CM3 6LD
20-96643
03/04/2020
16/04/2020
Matthew Somerville 24/04/2020
Hestur Kings Parade Cliff Slip Not Given
1494823 10.50
BH3 10.95
Not Given U
Brown CLAY
1 2.00
75.67 210
37.58 3.8
1.90 251
30 125
1.46 Brittle
0.63 0.23
Note: Deviator stress corrected for area change and membrane effects. Mohr circles and their interpretation is not covered by BS1377.
This is provided for information only.
Opinions and interpretations expressed herein are outside of the scope of the UKAS Accreditation. This
report may not be reproduced other than in full without the prior written approval of the issuing
laboratory. The results included within the report are representative of the samples submitted for
analysis.Page 1 of 1 Date Reported: 30/04/2020 GF 184.10
0
50
100
150
200
250
300
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25
Corr
ecte
d D
evia
tor
Str
ess kP
a
Axial Strain %
Deviator Stress v Axial Strain
0
50
100
150
200
250
300
0 50 100 150 200 250 300 350 400 450 500 550 600
Shear
Str
ength
kP
a
Normal Stresses kPa
Mohr Circles
Szczepan BielatowiczPL Deputy of Head of Geotechnical Section
TEST CERTIFICATEUnconsolidated Undrained
Triaxial Compression
Tested in Accordance with:
BS 1377-7: 1990: Clause 8
Client: Client Reference:
Client Address: Job Number:
Date Sampled:
Date Received:
Contact: Date Tested:
Site Address: Sampled By:
Testing carried out at i2 Analytical Limited, ul. Pionierow 39, 41-711 Ruda Slaska, Poland
Test Results:
Laboratory Reference: Depth Top [m]:
Hole No.: Depth Base [m]:
Sample Reference: Sample Type:
Sample Description:
Test Number Rate of Strain %/min
Length mm Cell Pressure kPa
Diameter mm Axial Strain at failure %
Bulk Density Mg/m3 Deviator Stress, ( σ1 - σ3 )f kPa
Moisture Content % Undrained Shear Strength, cu kPa ½( σ1 - σ3 )f
Dry Density Mg/m3 Mode of Failure
Membrane Correction kPa Membrane thickness mm
Position within sample
Remarks:
Signed:
for and on behalf of i2 Analytical Ltd
Endeavour Drilling J4280
Unit 7 Mapledean Industrial Estate, Maldon Road,
Chelmsford, CM3 6LD
20-96643
03/04/2020
16/04/2020
Matthew Somerville 24/04/2020
Hestur Kings Parade Cliff Slip Not Given
1494825 13.50
BH3 13.95
Not Given U
Brown CLAY
1 2.00
75.05 270
37.40 3.5
1.93 292
31 146
1.48 Brittle
0.56 0.22
Note: Deviator stress corrected for area change and membrane effects. Mohr circles and their interpretation is not covered by BS1377.
This is provided for information only.
Opinions and interpretations expressed herein are outside of the scope of the UKAS Accreditation. This
report may not be reproduced other than in full without the prior written approval of the issuing
laboratory. The results included within the report are representative of the samples submitted for
analysis.Page 1 of 1 Date Reported: 30/04/2020 GF 184.10
0
50
100
150
200
250
300
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25
Corr
ecte
d D
evia
tor
Str
ess kP
a
Axial Strain %
Deviator Stress v Axial Strain
0
50
100
150
200
250
300
0 50 100 150 200 250 300 350 400 450 500 550 600
Shear
Str
ength
kP
a
Normal Stresses kPa
Mohr Circles
Szczepan BielatowiczPL Deputy of Head of Geotechnical Section
TEST CERTIFICATEUnconsolidated Undrained
Triaxial Compression
Tested in Accordance with:
BS 1377-7: 1990: Clause 8
Client: Client Reference:
Client Address: Job Number:
Date Sampled:
Date Received:
Contact: Date Tested:
Site Address: Sampled By:
Testing carried out at i2 Analytical Limited, ul. Pionierow 39, 41-711 Ruda Slaska, Poland
Test Results:
Laboratory Reference: Depth Top [m]:
Hole No.: Depth Base [m]:
Sample Reference: Sample Type:
Sample Description:
Test Number Rate of Strain %/min
Length mm Cell Pressure kPa
Diameter mm Axial Strain at failure %
Bulk Density Mg/m3 Deviator Stress, ( σ1 - σ3 )f kPa
Moisture Content % Undrained Shear Strength, cu kPa ½( σ1 - σ3 )f
Dry Density Mg/m3 Mode of Failure
Membrane Correction kPa Membrane thickness mm
Position within sample
Remarks:
Signed:
for and on behalf of i2 Analytical Ltd
Endeavour Drilling J4280
Unit 7 Mapledean Industrial Estate, Maldon Road,
Chelmsford, CM3 6LD
20-96643
03/04/2020
16/04/2020
Matthew Somerville 24/04/2020
Hestur Kings Parade Cliff Slip Not Given
1494827 16.50
BH3 16.95
Not Given U
Brown CLAY
1 0.03
75.16 330
37.43 4.7
1.94 515
31 258
1.48 Compound
0.69 0.20
Note: Deviator stress corrected for area change and membrane effects. Mohr circles and their interpretation is not covered by BS1377.
This is provided for information only.
Opinions and interpretations expressed herein are outside of the scope of the UKAS Accreditation. This
report may not be reproduced other than in full without the prior written approval of the issuing
laboratory. The results included within the report are representative of the samples submitted for
analysis.Page 1 of 1 Date Reported: 30/04/2020 GF 184.10
0
100
200
300
400
500
600
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25
Corr
ecte
d D
evia
tor
Str
ess kP
a
Axial Strain %
Deviator Stress v Axial Strain
0
100
200
300
400
500
600
0 100 200 300 400 500 600 700 800 900 1000 1100 1200
Shear
Str
ength
kP
a
Normal Stresses kPa
Mohr Circles
Szczepan BielatowiczPL Deputy of Head of Geotechnical Section
TEST CERTIFICATEUnconsolidated Undrained
Triaxial Compression
Tested in Accordance with:
BS 1377-7: 1990: Clause 8
Client: Client Reference:
Client Address: Job Number:
Date Sampled:
Date Received:
Contact: Date Tested:
Site Address: Sampled By:
Testing carried out at i2 Analytical Limited, ul. Pionierow 39, 41-711 Ruda Slaska, Poland
Test Results:
Laboratory Reference: Depth Top [m]:
Hole No.: Depth Base [m]:
Sample Reference: Sample Type:
Sample Description:
Test Number Rate of Strain %/min
Length mm Cell Pressure kPa
Diameter mm Axial Strain at failure %
Bulk Density Mg/m3 Deviator Stress, ( σ1 - σ3 )f kPa
Moisture Content % Undrained Shear Strength, cu kPa ½( σ1 - σ3 )f
Dry Density Mg/m3 Mode of Failure
Membrane Correction kPa Membrane thickness mm
Position within sample
Remarks:
Signed:
for and on behalf of i2 Analytical Ltd
Endeavour Drilling J4280
Unit 7 Mapledean Industrial Estate, Maldon Road,
Chelmsford, CM3 6LD
20-96643
03/04/2020
16/04/2020
Matthew Somerville 24/04/2020
Hestur Kings Parade Cliff Slip Not Given
1494829 19.50
BH3 19.95
Not Given U
Brown CLAY
1 2.00
75.00 390
36.72 5.6
1.93 466
32 233
1.47 Brittle
0.78 0.19
Note: Deviator stress corrected for area change and membrane effects. Mohr circles and their interpretation is not covered by BS1377.
This is provided for information only.
Opinions and interpretations expressed herein are outside of the scope of the UKAS Accreditation. This
report may not be reproduced other than in full without the prior written approval of the issuing
laboratory. The results included within the report are representative of the samples submitted for
analysis.Page 1 of 1 Date Reported: 30/04/2020 GF 184.10
0
100
200
300
400
500
600
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25
Corr
ecte
d D
evia
tor
Str
ess kP
a
Axial Strain %
Deviator Stress v Axial Strain
0
100
200
300
400
500
600
0 100 200 300 400 500 600 700 800 900 1000 1100 1200
Shear
Str
ength
kP
a
Normal Stresses kPa
Mohr Circles
Szczepan BielatowiczPL Deputy of Head of Geotechnical Section
TEST CERTIFICATEUnconsolidated Undrained
Triaxial Compression
Tested in Accordance with:
BS 1377-7: 1990: Clause 8
Client: Client Reference:
Client Address: Job Number:
Date Sampled:
Date Received:
Contact: Date Tested:
Site Address: Sampled By:
Testing carried out at i2 Analytical Limited, ul. Pionierow 39, 41-711 Ruda Slaska, Poland
Test Results:
Laboratory Reference: Depth Top [m]:
Hole No.: Depth Base [m]:
Sample Reference: Sample Type:
Sample Description:
Test Number Rate of Strain %/min
Length mm Cell Pressure kPa
Diameter mm Axial Strain at failure %
Bulk Density Mg/m3 Deviator Stress, ( σ1 - σ3 )f kPa
Moisture Content % Undrained Shear Strength, cu kPa ½( σ1 - σ3 )f
Dry Density Mg/m3 Mode of Failure
Membrane Correction kPa Membrane thickness mm
Position within sample
Remarks:
Signed:
for and on behalf of i2 Analytical Ltd
Endeavour Drilling J4280
Unit 7 Mapledean Industrial Estate, Maldon Road,
Chelmsford, CM3 6LD
20-96643
06/04/2020
16/04/2020
Matthew Somerville 24/04/2020
Hestur Kings Parade Cliff Slip Not Given
1494831 2.50
BH4 2.95
Not Given U
Brown CLAY
1 2.00
192.94 50
101.71 5.9
1.93 167
30 83
1.48 Brittle
0.46 0.30
Note: Deviator stress corrected for area change and membrane effects. Mohr circles and their interpretation is not covered by BS1377.
This is provided for information only.
Opinions and interpretations expressed herein are outside of the scope of the UKAS Accreditation. This
report may not be reproduced other than in full without the prior written approval of the issuing
laboratory. The results included within the report are representative of the samples submitted for
analysis.Page 1 of 1 Date Reported: 30/04/2020 GF 184.10
0
50
100
150
200
250
300
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25
Corr
ecte
d D
evia
tor
Str
ess kP
a
Axial Strain %
Deviator Stress v Axial Strain
0
25
50
75
100
125
150
0 25 50 75 100 125 150 175 200 225 250 275 300
Shear
Str
ength
kP
a
Normal Stresses kPa
Mohr Circles
Szczepan BielatowiczPL Deputy of Head of Geotechnical Section
TEST CERTIFICATEUnconsolidated Undrained
Triaxial Compression
Tested in Accordance with:
BS 1377-7: 1990: Clause 8
Client: Client Reference:
Client Address: Job Number:
Date Sampled:
Date Received:
Contact: Date Tested:
Site Address: Sampled By:
Testing carried out at i2 Analytical Limited, ul. Pionierow 39, 41-711 Ruda Slaska, Poland
Test Results:
Laboratory Reference: Depth Top [m]:
Hole No.: Depth Base [m]:
Sample Reference: Sample Type:
Sample Description:
Test Number Rate of Strain %/min
Length mm Cell Pressure kPa
Diameter mm Axial Strain at failure %
Bulk Density Mg/m3 Deviator Stress, ( σ1 - σ3 )f kPa
Moisture Content % Undrained Shear Strength, cu kPa ½( σ1 - σ3 )f
Dry Density Mg/m3 Mode of Failure
Membrane Correction kPa Membrane thickness mm
Position within sample
Remarks:
Signed:
for and on behalf of i2 Analytical Ltd
Endeavour Drilling J4280
Unit 7 Mapledean Industrial Estate, Maldon Road,
Chelmsford, CM3 6LD
20-96643
06/04/2020
16/04/2020
Matthew Somerville 24/04/2020
Hestur Kings Parade Cliff Slip Not Given
1494833 4.50
BH4 4.95
Not Given U
Brown CLAY
1 2.00
191.62 90
102.13 6.4
1.96 232
33 116
1.48 Compound
0.52 0.32
Note: Deviator stress corrected for area change and membrane effects. Mohr circles and their interpretation is not covered by BS1377.
This is provided for information only.
Opinions and interpretations expressed herein are outside of the scope of the UKAS Accreditation. This
report may not be reproduced other than in full without the prior written approval of the issuing
laboratory. The results included within the report are representative of the samples submitted for
analysis.Page 1 of 1 Date Reported: 30/04/2020 GF 184.10
0
50
100
150
200
250
300
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25
Corr
ecte
d D
evia
tor
Str
ess kP
a
Axial Strain %
Deviator Stress v Axial Strain
0
50
100
150
200
250
300
0 50 100 150 200 250 300 350 400 450 500 550 600
Shear
Str
ength
kP
a
Normal Stresses kPa
Mohr Circles
Szczepan BielatowiczPL Deputy of Head of Geotechnical Section
TEST CERTIFICATEUnconsolidated Undrained
Triaxial Compression
Tested in Accordance with:
BS 1377-7: 1990: Clause 8
Client: Client Reference:
Client Address: Job Number:
Date Sampled:
Date Received:
Contact: Date Tested:
Site Address: Sampled By:
Testing carried out at i2 Analytical Limited, ul. Pionierow 39, 41-711 Ruda Slaska, Poland
Test Results:
Laboratory Reference: Depth Top [m]:
Hole No.: Depth Base [m]:
Sample Reference: Sample Type:
Sample Description:
Test Number Rate of Strain %/min
Length mm Cell Pressure kPa
Diameter mm Axial Strain at failure %
Bulk Density Mg/m3 Deviator Stress, ( σ1 - σ3 )f kPa
Moisture Content % Undrained Shear Strength, cu kPa ½( σ1 - σ3 )f
Dry Density Mg/m3 Mode of Failure
Membrane Correction kPa Membrane thickness mm
Position within sample
Remarks:
Signed:
for and on behalf of i2 Analytical Ltd
Endeavour Drilling J4280
Unit 7 Mapledean Industrial Estate, Maldon Road,
Chelmsford, CM3 6LD
20-96643
06/04/2020
16/04/2020
Matthew Somerville 24/04/2020
Hestur Kings Parade Cliff Slip Not Given
1494835 7.50
BH4 7.95
Not Given U
Brown CLAY
1 2.00
191.96 150
102.51 7.8
1.95 302
32 151
1.48 Brittle
0.51 0.28
Note: Deviator stress corrected for area change and membrane effects. Mohr circles and their interpretation is not covered by BS1377.
This is provided for information only.
Opinions and interpretations expressed herein are outside of the scope of the UKAS Accreditation. This
report may not be reproduced other than in full without the prior written approval of the issuing
laboratory. The results included within the report are representative of the samples submitted for
analysis.Page 1 of 1 Date Reported: 30/04/2020 GF 184.10
0
100
200
300
400
500
600
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25
Corr
ecte
d D
evia
tor
Str
ess kP
a
Axial Strain %
Deviator Stress v Axial Strain
0
50
100
150
200
250
300
0 50 100 150 200 250 300 350 400 450 500 550 600
Shear
Str
ength
kP
a
Normal Stresses kPa
Mohr Circles
Szczepan BielatowiczPL Deputy of Head of Geotechnical Section
TEST CERTIFICATEUnconsolidated Undrained
Triaxial Compression
Tested in Accordance with:
BS 1377-7: 1990: Clause 8
Client: Client Reference:
Client Address: Job Number:
Date Sampled:
Date Received:
Contact: Date Tested:
Site Address: Sampled By:
Testing carried out at i2 Analytical Limited, ul. Pionierow 39, 41-711 Ruda Slaska, Poland
Test Results:
Laboratory Reference: Depth Top [m]:
Hole No.: Depth Base [m]:
Sample Reference: Sample Type:
Sample Description:
Test Number Rate of Strain %/min
Length mm Cell Pressure kPa
Diameter mm Axial Strain at failure %
Bulk Density Mg/m3 Deviator Stress, ( σ1 - σ3 )f kPa
Moisture Content % Undrained Shear Strength, cu kPa ½( σ1 - σ3 )f
Dry Density Mg/m3 Mode of Failure
Membrane Correction kPa Membrane thickness mm
Position within sample
Remarks:
Signed:
for and on behalf of i2 Analytical Ltd
Endeavour Drilling J4280
Unit 7 Mapledean Industrial Estate, Maldon Road,
Chelmsford, CM3 6LD
20-96643
07/04/2020
16/04/2020
Matthew Somerville 24/04/2020
Hestur Kings Parade Cliff Slip Not Given
1494837 2.50
BH6 2.95
Not Given U
Brown CLAY
1 2.00
74.95 50
36.83 4.5
1.97 127
35 63
1.46 Compound
0.60 0.18
Note: Deviator stress corrected for area change and membrane effects. Mohr circles and their interpretation is not covered by BS1377.
This is provided for information only.
Opinions and interpretations expressed herein are outside of the scope of the UKAS Accreditation. This
report may not be reproduced other than in full without the prior written approval of the issuing
laboratory. The results included within the report are representative of the samples submitted for
analysis.Page 1 of 1 Date Reported: 30/04/2020 GF 184.10
0
50
100
150
200
250
300
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25
Corr
ecte
d D
evia
tor
Str
ess kP
a
Axial Strain %
Deviator Stress v Axial Strain
0
25
50
75
100
125
150
0 25 50 75 100 125 150 175 200 225 250 275 300
Shear
Str
ength
kP
a
Normal Stresses kPa
Mohr Circles
Szczepan BielatowiczPL Deputy of Head of Geotechnical Section
TEST CERTIFICATEUnconsolidated Undrained
Triaxial Compression
Tested in Accordance with:
BS 1377-7: 1990: Clause 8
Client: Client Reference:
Client Address: Job Number:
Date Sampled:
Date Received:
Contact: Date Tested:
Site Address: Sampled By:
Testing carried out at i2 Analytical Limited, ul. Pionierow 39, 41-711 Ruda Slaska, Poland
Test Results:
Laboratory Reference: Depth Top [m]:
Hole No.: Depth Base [m]:
Sample Reference: Sample Type:
Sample Description:
Test Number Rate of Strain %/min
Length mm Cell Pressure kPa
Diameter mm Axial Strain at failure %
Bulk Density Mg/m3 Deviator Stress, ( σ1 - σ3 )f kPa
Moisture Content % Undrained Shear Strength, cu kPa ½( σ1 - σ3 )f
Dry Density Mg/m3 Mode of Failure
Membrane Correction kPa Membrane thickness mm
Position within sample
Remarks:
Signed:
for and on behalf of i2 Analytical Ltd
Endeavour Drilling J4280
Unit 7 Mapledean Industrial Estate, Maldon Road,
Chelmsford, CM3 6LD
20-96643
07/04/2020
16/04/2020
Matthew Somerville 24/04/2020
Hestur Kings Parade Cliff Slip Not Given
1494839 4.50
BH6 4.95
Not Given U
Brown CLAY
1 2.00
75.03 80
36.88 4.4
1.93 286
32 143
1.47 Compound
0.56 0.17
Note: Deviator stress corrected for area change and membrane effects. Mohr circles and their interpretation is not covered by BS1377.
This is provided for information only.
Opinions and interpretations expressed herein are outside of the scope of the UKAS Accreditation. This
report may not be reproduced other than in full without the prior written approval of the issuing
laboratory. The results included within the report are representative of the samples submitted for
analysis.Page 1 of 1 Date Reported: 30/04/2020 GF 184.10
0
50
100
150
200
250
300
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25
Corr
ecte
d D
evia
tor
Str
ess kP
a
Axial Strain %
Deviator Stress v Axial Strain
0
50
100
150
200
250
300
0 50 100 150 200 250 300 350 400 450 500 550 600
Shear
Str
ength
kP
a
Normal Stresses kPa
Mohr Circles
Szczepan BielatowiczPL Deputy of Head of Geotechnical Section
TEST CERTIFICATEUnconsolidated Undrained
Triaxial Compression
Tested in Accordance with:
BS 1377-7: 1990: Clause 8
Client: Client Reference:
Client Address: Job Number:
Date Sampled:
Date Received:
Contact: Date Tested:
Site Address: Sampled By:
Testing carried out at i2 Analytical Limited, ul. Pionierow 39, 41-711 Ruda Slaska, Poland
Test Results:
Laboratory Reference: Depth Top [m]:
Hole No.: Depth Base [m]:
Sample Reference: Sample Type:
Sample Description:
Test Number Rate of Strain %/min
Length mm Cell Pressure kPa
Diameter mm Axial Strain at failure %
Bulk Density Mg/m3 Deviator Stress, ( σ1 - σ3 )f kPa
Moisture Content % Undrained Shear Strength, cu kPa ½( σ1 - σ3 )f
Dry Density Mg/m3 Mode of Failure
Membrane Correction kPa Membrane thickness mm
Position within sample
Remarks:
Signed:
for and on behalf of i2 Analytical Ltd
Endeavour Drilling J4280
Unit 7 Mapledean Industrial Estate, Maldon Road,
Chelmsford, CM3 6LD
20-96643
07/04/2020
16/04/2020
Matthew Somerville 24/04/2020
Hestur Kings Parade Cliff Slip Not Given
1494842 7.50
BH6 7.95
Not Given U
Brown CLAY
1 2.00
74.86 150
37.62 8.3
1.92 363
32 181
1.46 Compound
1.04 0.20
Note: Deviator stress corrected for area change and membrane effects. Mohr circles and their interpretation is not covered by BS1377.
This is provided for information only.
Opinions and interpretations expressed herein are outside of the scope of the UKAS Accreditation. This
report may not be reproduced other than in full without the prior written approval of the issuing
laboratory. The results included within the report are representative of the samples submitted for
analysis.Page 1 of 1 Date Reported: 30/04/2020 GF 184.10
0
100
200
300
400
500
600
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25
Corr
ecte
d D
evia
tor
Str
ess kP
a
Axial Strain %
Deviator Stress v Axial Strain
0
50
100
150
200
250
300
0 50 100 150 200 250 300 350 400 450 500 550 600
Shear
Str
ength
kP
a
Normal Stresses kPa
Mohr Circles
Szczepan BielatowiczPL Deputy of Head of Geotechnical Section