Ground Floor Plan Roof Plan - live.ipcn.nsw.gov.au · pMrojeactcarthur Memorial Park Varroville...

15
project Macarthur Memorial Park Varroville Outbuildings 166-170 St Andrews Road Varroville Former Coach House -Existing Ground Floor Plan & Roof Plan MD.101 1711 www.architecturalprojects.net.au A tel. +61 (0)2 8303 1700 Gary O'Reilly | nominated architect no. 4796 25/8/17 File Path - /Volumes/Server Files/04. CAD/Current projects/1711 166-170 St Andrews Road Varoville/Client/166- 170 St Andrews Road Varoville MD B Action Conservation.pln DEVELOPMENT APPLICATION NOT FOR CONSTRUCTION drawing plot date revision drawing no. Architectural Projects 01 W105 FFL + 74.450 GD02 GW02 GW01 GD03 GD01 G02 G03 G01 AD.01 over 1 23 AD.02 over MD203 01 W105 MD203 10m 0 1 5 Ground Floor Plan Roof Plan

Transcript of Ground Floor Plan Roof Plan - live.ipcn.nsw.gov.au · pMrojeactcarthur Memorial Park Varroville...

Page 1: Ground Floor Plan Roof Plan - live.ipcn.nsw.gov.au · pMrojeactcarthur Memorial Park Varroville Outbuildings 166-170 St Andrews Road Varroville wtewl. w+6.a1r c(h0)i2te c8t3u0ra3l

project

Macarthur Memorial Park Varroville Outbuildings166-170 St Andrews Road Varroville Former Coach House -Existing Ground Floor Plan & Roof Plan MD.1011711

www.architecturalprojects.net.auAtel. +61 (0)2 8303 1700

Gary O'Reilly | nominated architect no. 4796

25/8/17

File Path -/Volumes/Server Files/04. CAD/Current projects/1711 166-170 St Andrews Road Varoville/Client/166- 170 St Andrews Road Varoville MD B Action Conservation.pln

DEVELOPMENT APPLICATIONNOT FOR CONSTRUCTION

drawing plot date revisiondrawing no.Architectural Projects

01W105

FFL + 74.450

GD02

GW02

GW01

GD03

GD01

G02

G03

G01

AD.01 over

123

AD.02 over

MD203

01W105MD203

10m0 1 5

Ground Floor Plan Roof Plan

Page 2: Ground Floor Plan Roof Plan - live.ipcn.nsw.gov.au · pMrojeactcarthur Memorial Park Varroville Outbuildings 166-170 St Andrews Road Varroville wtewl. w+6.a1r c(h0)i2te c8t3u0ra3l

project

Macarthur Memorial Park Varroville Outbuildings166-170 St Andrews Road Varroville Former Coach House -Existing Elevations MD.1021711

www.architecturalprojects.net.auAtel. +61 (0)2 8303 1700

Gary O'Reilly | nominated architect no. 4796

25/8/17

File Path -/Volumes/Server Files/04. CAD/Current projects/1711 166-170 St Andrews Road Varoville/Client/166- 170 St Andrews Road Varoville MD B Action Conservation.pln

DEVELOPMENT APPLICATIONNOT FOR CONSTRUCTION

drawing plot date revisiondrawing no.Architectural Projects

RL + 74.26RL + 74.30FFL+ 74.450 RL +74.44

RL + 74.26

AD.01

FFL+ 74.450

RL +74.44 RL +74.45DG02

GD01

FFL+ 74.450 RL + 74.30RL + 74.47

AD.02

FFL+ 74.450

10m0 1 5

South Elevation East Elevation

North Elevation West Elevation

Page 3: Ground Floor Plan Roof Plan - live.ipcn.nsw.gov.au · pMrojeactcarthur Memorial Park Varroville Outbuildings 166-170 St Andrews Road Varroville wtewl. w+6.a1r c(h0)i2te c8t3u0ra3l

project

Macarthur Memorial Park Varroville Outbuildings166-170 St Andrews Road Varroville Former Coach House-Section 01 MD.1031711

www.architecturalprojects.net.auAtel. +61 (0)2 8303 1700

Gary O'Reilly | nominated architect no. 4796

25/8/17

File Path -/Volumes/Server Files/04. CAD/Current projects/1711 166-170 St Andrews Road Varoville/Client/166- 170 St Andrews Road Varoville MD B Action Conservation.pln

DEVELOPMENT APPLICATIONNOT FOR CONSTRUCTION

drawing plot date revisiondrawing no.Architectural Projects

10m0 1 5

RL + 74.47

RL + 74.30

AD.01

FFL+ 74.450

Section 01 Former Coach House

Page 4: Ground Floor Plan Roof Plan - live.ipcn.nsw.gov.au · pMrojeactcarthur Memorial Park Varroville Outbuildings 166-170 St Andrews Road Varroville wtewl. w+6.a1r c(h0)i2te c8t3u0ra3l

project

Macarthur Memorial Park Varroville Outbuildings166-170 St Andrews Road Varroville Cottage -Existing Ground Floor Plan & Roof Plan MD.2011711

www.architecturalprojects.net.auAtel. +61 (0)2 8303 1700

Gary O'Reilly | nominated architect no. 4796

25/8/17

File Path -/Volumes/Server Files/04. CAD/Current projects/1711 166-170 St Andrews Road Varoville/Client/166- 170 St Andrews Road Varoville MD B Action Conservation.pln

DEVELOPMENT APPLICATIONNOT FOR CONSTRUCTION

drawing plot date revisiondrawing no.Architectural Projects

10m0 1 5

01W206

01W206

MD103

MD103

01W206

01W206

FFL + 74.590

GW03 GW02 GW01

GW04 GW05

GW06

GW

07

GW08

GW09

GW10

G02G01

G03 G04 G05 G06 G09

G08

G07

GD01

GD02

GD03 GD04 GD05

GD

06

GD07

GD08

GD09

GD10

GD11

GW11

GW12

MD103

MD103

Roof PlanCottage -Existing Ground Floor Plan

Page 5: Ground Floor Plan Roof Plan - live.ipcn.nsw.gov.au · pMrojeactcarthur Memorial Park Varroville Outbuildings 166-170 St Andrews Road Varroville wtewl. w+6.a1r c(h0)i2te c8t3u0ra3l

project

Macarthur Memorial Park Varroville Outbuildings166-170 St Andrews Road Varroville Cottage- Existing Elevations MD.2021711

www.architecturalprojects.net.auAtel. +61 (0)2 8303 1700

Gary O'Reilly | nominated architect no. 4796

25/8/17

File Path -/Volumes/Server Files/04. CAD/Current projects/1711 166-170 St Andrews Road Varoville/Client/166- 170 St Andrews Road Varoville MD B Action Conservation.pln

DEVELOPMENT APPLICATIONNOT FOR CONSTRUCTION

drawing plot date revisiondrawing no.Architectural Projects

GD09

RL + 73.70RL+ 74.05

FFL + 74.59

GW06

GW04 GW05 GW07GW08

FFL + 74.59RL + 73,70 RL + 73,75

GW09

FFL + 74.59RL + 74,350

GW03GW02GW01 GD01

FFL + 74.59GW10

GW11

10m0 1 5

South Elevation East Elevation

West ElevationNorth Elevation

Page 6: Ground Floor Plan Roof Plan - live.ipcn.nsw.gov.au · pMrojeactcarthur Memorial Park Varroville Outbuildings 166-170 St Andrews Road Varroville wtewl. w+6.a1r c(h0)i2te c8t3u0ra3l

project

Macarthur Memorial Park Varroville Outbuildings166-170 St Andrews Road Varroville Cottage-Section 01 MD.2031711

www.architecturalprojects.net.auAtel. +61 (0)2 8303 1700

Gary O'Reilly | nominated architect no. 4796

25/8/17

File Path -/Volumes/Server Files/04. CAD/Current projects/1711 166-170 St Andrews Road Varoville/Client/166- 170 St Andrews Road Varoville MD B Action Conservation.pln

DEVELOPMENT APPLICATIONNOT FOR CONSTRUCTION

drawing plot date revisiondrawing no.Architectural Projects

10m0 1 5

RL + 74.20RL + 74.31FFL + 74.59

Section 01 cottage1:100

Page 7: Ground Floor Plan Roof Plan - live.ipcn.nsw.gov.au · pMrojeactcarthur Memorial Park Varroville Outbuildings 166-170 St Andrews Road Varroville wtewl. w+6.a1r c(h0)i2te c8t3u0ra3l

0 1 5m2 2.5

DEVELOPMENT APPLICATIONNOT FOR CONSTRUCTION

N

issue amendment date

drawing

scale drawn checked

Project No. revision

Electrical

Mechanical

Landscape

Hydraulic

Survey

Structural -

-

-

-

-

-

The contractor shall confirm on site existing dimensions and conditionsbefore commencement of works. All discrepancies should be reportedto the architect for instructions

Reproduction of this drawing is prohibited without the consent ofArchitectural Projects Pty. Ltd.

Architectural Projects does not accept responsibility for the dimensionalaccuracy of any data contained in CAD or other attachements as it maybe based on third party origin information. All information should beverified in writing.

This drawing has been prepared in conjunctionwith the following drawings:

Architectural Projects Pty. Ltd.©

project

Macarthur Memorial ParkVarroville Outbuildings166-170 St Andrews RoadVarroville

Former Coach House Ground Floor Plan

1711

GO

DA.101

plot date

25/8/17

File Path -/Volumes/Server Files/04. CAD/Current projects/1711 166-170 St Andrews Road Varoville/Client/166- 170 St Andrews Road Varoville MD B Action Conservation.pln

Gary O'Reilly - Registered Architect No. 4796

Architectural Projects Pty. Ltd.-, ABN 78 003 526 823

tel +61 (02) 8303 1700.-, fax +61(02) 9319 1128.-,

architects@architectural projects.net.au -,www.architectural projects.net.authe Foundry.-, Studio 1 / 181 Lawson St, Darlington.-, NSW Australia 2008

drawing No.

TC1:50 @ A1@ A3-

File Path -/Volumes/Server Files/04. CAD/Current projects/1711 166-170 St Andrews Road Varoville/Client/166- 170 St Andrews Road Varoville MD B Action Conservation.pln

Preliminary Issue 01 06 17-

Development Application 25 08 17A

A

01W105

FFL + 74.450

Landing Platform over dotted

GD02

GW02

GW01

GD03

GD01

G02

G03

G01

G04

AD.01 over

1

23

GD04GD05GD06C04

C03 C02 C01

C06 C05

C07C08C09C10C11

AD.02 over

New timber column to support existing double beamover. Footing detail to match column C06

Remove existing temporary steel columns and replacewith new timber column to engineer detail. Carefully cutout section of existing slab for new concrete footing.Finish to top of footing to match existing concrete slab .Provide full depth construction joint between existingslab and new footing

Brick crack repair and brick tie joints to engineersdetails

Remove existing electrical cabinet and conducts andmake good to existing wall

Brick crack repair and brick tiejoints to engineers details

Clean off existing concrete slab

Existing timber beams over (dotted)

New verandah beam over (dotted)

New timber columns to detail

conc-ex

conc-ex

conc-ex

conc-ex

Fall

Fall

NOTES:

1. Conservation Works ScheduleThe conservation works schedule prepared by ArchitecturalProjects should be read in conjunction with these drawings.

2. Existing Concrete SlabsRetain and repair as necessary to match existing slab to G04 -remove all existing soil and organic matter

3. Existing Timber Columns-C 01- C04-Remove lower deteriorated section and scarf newsection to match to existing column-C02- C03- Remove existing non- original column and replace tomatch column C01

4. New Timber Columns-C 05- C06- New to detail-C 07- C11- New timber to detail

5. Existing BrickworkReconstruct existing brickwork where it has collapsed to G01 andG04 (dotted) to match existing using salvaged bricks from site

6. Existing Timber WindowsRetain and protect existing windowsComplete maintenance works as scheduled

7. Existing DoorsRetain and make good existing door frame as scheduledInstall new door as scheduled to detail

8. Roof G04Collect all existing timber shingles that are currently on the groundCollect all loose existing timber shingles and store in palletslocated on site elevated on a temporary brickwork: Install a metalroof over the pallets which is fixed to the top of the pallet forprotection

Complete a photographic record of existing roof framing andconnections to existing roof prior to commencing any work anduse for reference in reconstruction of roofCarefully remove existing timber rafters, which have collapsed.Remove existing attached shingles and store as aboveRemove existing battensAssess each rafter and retain those rafers in suitable conditionRafters not suitable for reuse due to termites or dry rot damageshall be retained for repairs. Store as directed

Reconstruct roof to G04 in accordance with spacing and detail ofexisting roof framing. Timber sizes to match exactly the sizes andprofiles of existing rafters . Timber species to match existingInstall new additional timber rafters to augment the existing roof inaccordance with engineer details.

Install new timber verandah beam to match existing (fragment)Install new timber columns C07-C11 to detailInstall additional beam at mid spam to augment existing roofframing in accordance with engineer details

Install brass plaque confirming reconstruction to details. Refer toConstruction Works Schedule

LEGEND

CRACK REPAIR ANDREPAIR TO ENGINEER DETAILS

EXISTING REGRADING OFEXISTING GROUND LEVEL ( APPROX.)

RECONSTRUCT EXISTING BRICKWORKTO MATCH EXISTING

AdjustableBathBulkheadBrick PavingBasinBrickworkConcrete BlockworkColour backed glassControl JointCement RenderConcrete Roof TilesConcreteCheck On SiteChrome PlatedCupboardCarpetCeramic TilesDownpipeDamp Proof CourseDishwasherExisting Ceiling LevelExisting Floor LevelExisting Ground LineExpansion JointFace BrickworkFibre CementFinished Ceiling LevelFixed GlazingGel coated Fibre GlassFinished Ground LevelFire HydrantFire Hose ReelFinished Floor LevelFloor WasteFinished Structural LevelGranolithicHot PlateHardwoodHot Water UnitLaminate Finish

lvmdfmmcmrmrfmsmsbopglovpbdpcpconcplyrefRLrwhsscshshrskslrfspssststpvtctdtrttftphtrtrztvurvlwbwcwpmwrwrc

LouvreMed. Density FibreboardMirrorMetal CladdingMoisture ResistantMetal RoofingMild SteelMain SwitchboardOpaque GlazingOvenPlasterboardPolished ChromePolished ConcretePlywoodRefrigeratorReduced LevelRainwater HeadSinkSatin ChromeShadow LineShowerSkirtingSlate RoofingSet PlasterStainless SteelStoneStone PavingTerracottaTimber DeckingTerracotta Roof TilesTimber Strip FloorToilet Paper HolderTowel RailTerrazzoTimber Veneer (MDF)UrinalVinylWeatherboardWater ClosetWaterproofing MembraneWardrobeWestern Red Cedar

abbkhdbkpvbsnbwkcblkcbgcjcrcrtconccoscpcbdcptctdpdpcdwECLEFLEGLejFbwkfcFCLfgfgcFGLfhfhrFFLfwFSLgranohphwdhwulam

LEGEND

N

SCALE 1:50@A1

Ground Floor Plan-

01

Page 8: Ground Floor Plan Roof Plan - live.ipcn.nsw.gov.au · pMrojeactcarthur Memorial Park Varroville Outbuildings 166-170 St Andrews Road Varroville wtewl. w+6.a1r c(h0)i2te c8t3u0ra3l

0 1 5m2 2.5

DEVELOPMENT APPLICATIONNOT FOR CONSTRUCTION

N

issue amendment date

drawing

scale drawn checked

Project No. revision

Electrical

Mechanical

Landscape

Hydraulic

Survey

Structural -

-

-

-

-

-

The contractor shall confirm on site existing dimensions and conditionsbefore commencement of works. All discrepancies should be reportedto the architect for instructions

Reproduction of this drawing is prohibited without the consent ofArchitectural Projects Pty. Ltd.

Architectural Projects does not accept responsibility for the dimensionalaccuracy of any data contained in CAD or other attachements as it maybe based on third party origin information. All information should beverified in writing.

This drawing has been prepared in conjunctionwith the following drawings:

Architectural Projects Pty. Ltd.©

project

Macarthur Memorial ParkVarroville Outbuildings166-170 St Andrews RoadVarroville

Former Coach House Roof Plan

1711

GO

DA.102

plot date

25/8/17

File Path -/Volumes/Server Files/04. CAD/Current projects/1711 166-170 St Andrews Road Varoville/Client/166- 170 St Andrews Road Varoville MD B Action Conservation.pln

Gary O'Reilly - Registered Architect No. 4796

Architectural Projects Pty. Ltd.-, ABN 78 003 526 823

tel +61 (02) 8303 1700.-, fax +61(02) 9319 1128.-,

architects@architectural projects.net.au -,www.architectural projects.net.authe Foundry.-, Studio 1 / 181 Lawson St, Darlington.-, NSW Australia 2008

drawing No.

TC1:50 @ A1@ A3-

File Path -/Volumes/Server Files/04. CAD/Current projects/1711 166-170 St Andrews Road Varoville/Client/166- 170 St Andrews Road Varoville MD B Action Conservation.pln

Preliminary Issue 01 06 17-

Development Application 25 08 17A

A

01W105

Retain and protect existing corrugated steel roofing asscheduled

Install new galvanised steel ogee gutter and .. downpipesas specified

Replace existing timber barge board and install newedge roll to detailReplace existing ridge capping to detail

Reconstruct timber shingles roof under (dotted) to matchexisting

Retain and protect existing timber shingle roofing asspecifiedInstall new galvanised corrugated steel roof as specified

Reconstruct timber roof framing and timber shingles roofingas specifiedInstall new galvanised corrugated steel roofing as specified

Install new galvanised steel ogee gutter and downpipesas specified

Reconstruct timber shingles roof under (dotted) to matchexisting

Reconstruct timber boards and framing to existing catshead landing

Reconstruct timber shingles roof under( dotted ) tomatch existingRepair/infill corrugated steel roofing to match existing

Reconstruct timber shingles roofunder (dotted) to match existing

Replace existing ridge capping todetail

Replace existing timber barge board and install newedge roll to detailReplace existing ridge capping to detail

mrf

mrf

mrf-ex

mrf-ex

NOTES:

1. Conservation Works ScheduleThe conservation works schedule prepared by ArchitecturalProjects should be read in conjunction with these drawings

2. Existing Roof SheetingGenerally retain and protect existing roof sheeting "in situ" .Carefully inspect the roof space and identify areas required forrepairs. Replace and repair to match existing sheeting to achieve awater proof roofing system as scheduledRemove all modern Tek-screws and washersRetain all existing traditional roof fixings and lead washersRetighten all existing fixings to be retained. Replace wheredamaged. Replace missing and damaged lead washersInstall new roof fixings to match existing where missing or fixingsare to be replaced

3. Existing Timber Shingle Roofing.The original timber shingle roof remains extant under the existingcorrugated steel roofingRetain and protect the existing shingle roofing and prevent anydamage to the extant shinglesInspect the underseal of the shingles form with the roof space fortermites damage and active termites

4. Existing Flashingsinstall new lead soaker flashing for the chimney flueInspect all existing flashings and repair as required to matchexisting

5. GuttersReplace existing gutter with new galvanised ogee gutters. Installnew galvanised ogee gutter to the existing verandah

6. DownpipesInstall new 90mm OD galvanised downpipes as noted

AdjustableBathBulkheadBrick PavingBasinBrickworkConcrete BlockworkColour backed glassControl JointCement RenderConcrete Roof TilesConcreteCheck On SiteChrome PlatedCupboardCarpetCeramic TilesDownpipeDamp Proof CourseDishwasherExisting Ceiling LevelExisting Floor LevelExisting Ground LineExpansion JointFace BrickworkFibre CementFinished Ceiling LevelFixed GlazingGel coated Fibre GlassFinished Ground LevelFire HydrantFire Hose ReelFinished Floor LevelFloor WasteFinished Structural LevelGranolithicHot PlateHardwoodHot Water UnitLaminate Finish

lvmdfmmcmrmrfmsmsbopglovpbdpcpconcplyrefRLrwhsscshshrskslrfspssststpvtctdtrttftphtrtrztvurvlwbwcwpmwrwrc

LouvreMed. Density FibreboardMirrorMetal CladdingMoisture ResistantMetal RoofingMild SteelMain SwitchboardOpaque GlazingOvenPlasterboardPolished ChromePolished ConcretePlywoodRefrigeratorReduced LevelRainwater HeadSinkSatin ChromeShadow LineShowerSkirtingSlate RoofingSet PlasterStainless SteelStoneStone PavingTerracottaTimber DeckingTerracotta Roof TilesTimber Strip FloorToilet Paper HolderTowel RailTerrazzoTimber Veneer (MDF)UrinalVinylWeatherboardWater ClosetWaterproofing MembraneWardrobeWestern Red Cedar

abbkhdbkpvbsnbwkcblkcbgcjcrcrtconccoscpcbdcptctdpdpcdwECLEFLEGLejFbwkfcFCLfgfgcFGLfhfhrFFLfwFSLgranohphwdhwulam

LEGEND

N

SCALE 1:50@A1

Roof Plan-

01

Page 9: Ground Floor Plan Roof Plan - live.ipcn.nsw.gov.au · pMrojeactcarthur Memorial Park Varroville Outbuildings 166-170 St Andrews Road Varroville wtewl. w+6.a1r c(h0)i2te c8t3u0ra3l

0 1 5m2 2.5

DEVELOPMENT APPLICATIONNOT FOR CONSTRUCTION

issue amendment date

drawing

scale drawn checked

Project No. revision

Electrical

Mechanical

Landscape

Hydraulic

Survey

Structural -

-

-

-

-

-

The contractor shall confirm on site existing dimensions and conditionsbefore commencement of works. All discrepancies should be reportedto the architect for instructions

Reproduction of this drawing is prohibited without the consent ofArchitectural Projects Pty. Ltd.

Architectural Projects does not accept responsibility for the dimensionalaccuracy of any data contained in CAD or other attachements as it maybe based on third party origin information. All information should beverified in writing.

This drawing has been prepared in conjunctionwith the following drawings:

Architectural Projects Pty. Ltd.©

project

Macarthur Memorial ParkVarroville Outbuildings166-170 St Andrews RoadVarroville

Former Coach House Elevations

1711 DA.103

plot date

25/8/17

File Path -/Volumes/Server Files/04. CAD/Current projects/1711 166-170 St Andrews Road Varoville/Client/166- 170 St Andrews Road Varoville MD B Action Conservation.pln

Gary O'Reilly - Registered Architect No. 4796

Architectural Projects Pty. Ltd.-, ABN 78 003 526 823architects@architectural projects.net.au -,www.architectural projects.net.authe Foundry.-, Studio 1 / 181 Lawson St, Darlington.-, NSW Australia 2008

drawing No.

xx1:50 @ A1@ A3-

GO

tel +61 (02) 8303 1700.-, fax +61(02) 9319 1128.-,

File Path -/Volumes/Server Files/04. CAD/Current projects/1711 166-170 St Andrews Road Varoville/Client/166- 170 St Andrews Road Varoville MD B Action Conservation.pln

Preliminary Issue 01 06 17-

Development Application 25 08 17A

A

Reconstruct timber beam to head of opening based onextant evidence to existing columns C01, C04Reconstruct 3/no timber louvres over beam based onextant evidence to existing columns C01, C04

Existing timber columns C01, C04 to be replaced asscheduled

Reconstruct the timber boardeddoor as scheduled and to detailDG 04 - DG -06

Reconstruct timber boarded dooras scheduled and to detail

Remove and replace as requiredany existing roof framing to matchexisting

Existing timber columns C02, C03 to be repaired asscheduled to detail

Replace existing gutter and downpipes as scheduled

Remove existing capping to existing barge boardInstall new barge board and galvanised edge roll asspecifiedRemove existing capping to existing barge board

Install new barge board and galvanised edge roll asspecified

Replace existing ridge capping as specified

Repair existing pulley beam . Scarf new section on toexisting beam

Reconstruct existing timber cats head landing to matchexisting

NOTES:

1. Conservation Works ScheduleThe conservation works schedule prepared by ArchitecturalProjects should be read in conjunction with these drawings

2. Existing Roof SheetingGenerally retain and protect existing roof sheeting "in situ" .Carefully inspect the roof space and identify areas required forrepairs. Replace and repair to match existing sheeting to achievea water proof roofing system as scheduledRemove all modern Tek-screws and washersRetain all existing traditional roof fixing and lead washersRetighten all existing fixings to be retained. Replace wheredamaged. Replace missing and damaged lead washersInstall new roof fixings to match existing where missing or fixingsare to be replaced

3. Existing Timber Shingle Roofing to G01-G03The original timber shingle roof remains extant under the existingcorrugated steel roofingRetain and protect the existing shingle roofing and prevent anydamage to the extant shinglesInspect the underside of the shingles from within the roof spacefor termite damage and active termites

8. Roof G04Collect all existing timber shingles that are currently on the groundCollect all loose existing timber shingles and store in palletslocated on site elevated on a temporary brickwork: Install a metalroof over the pallets which is fixed to the top of the pallet forprotection

Complete a photographic record of the existing roof framing andconnections to existing roof prior to commencing any work anduse for reference in reconstruction of roofCarefully remove existing timber rafters, which have collapsed.Remove existing attached shingles and store as aboveRemove existing battensAssess each rafter and retain those rafers in suitable conditionRafters not suitable for reuse due to termites or dry rot damageshall be retained for repairs. Store as directed

Reconstruct roof to G04 in accordance with spacing and detail ofexisting roof framing. Timber sizes to match exactly the sizes andprofiles of existing rafters . Timber species to match existingInstall new additional timber rafters to augment the existing roof inaccordance with engineer details.

Install new timber verandah beam to match existing (fragment)Install new timber columns C07-C11 to detailInstall additional beam at mid spam to augment existing roofframing in accordance with engineer details

Install brass plaque confirming reconstruction to details. Refer toConstruction Works Schedule

DG02DG06DG05DG04 C04C03C02C01

GD01

FFL+ 74.450 EFL

Existing lapped points in corrugated steel roofing to beretained

Cracks repair toexisting render todetail

Reconstruct timber shingles roofunder (dotted) to match existingReconstruct timber shingles roof

under (dotted) to match existingReplace existing timber barge board and install newedge roll to detailReplace existing ridge capping to detail Replace existing timber barge board and install new

edge roll to detailReplace existing ridge capping to detail

cr-ex

mrf-ex

mrf-ex

mrf-ex

dp

Remove existing capping to existing barge boardInstall new barge board and galvanised edge roll asspecified

Remove existing capping to existing barge boardInstall new barge board and galvanised edge roll asspecified

Crack replace to engineer details

Remove existing steel plate and tension bar and makegood to existing wall and render

Replace and clean existing stone foundation asspecified

Repair existing stone sill as specified

Retain and repair existing timber window asscheduled

Remove existing timber door andreconstruct timber window to openingas scheduled

Retain and repair ... reconstruct existingwindow as scheduled

EXISTING BUILDING TO BE DEMOLISHED

REPLACE OR INFILL RENDER TO MATCHEXISTING APPROXIMATE ONLY TO BEDETERMINED ON SITE

CRACK REPAIR TO DETAIL

LEGEND

WG02WG01

AD.02

FFL+ 74.450 EFL

Replace existing timber barge board and install new edge roll to detailReplace existing ridge capping to detail

cr-ex

cr-ex

st-ex

st-ex

st-ex

dpdp

AdjustableBathBulkheadBrick PavingBasinBrickworkConcrete BlockworkColour backed glassControl JointCement RenderConcrete Roof TilesConcreteCheck On SiteChrome PlatedCupboardCarpetCeramic TilesDownpipeDamp Proof CourseDishwasherExisting Ceiling LevelExisting Floor LevelExisting Ground LineExpansion JointFace BrickworkFibre CementFinished Ceiling LevelFixed GlazingGel coated Fibre GlassFinished Ground LevelFire HydrantFire Hose ReelFinished Floor LevelFloor WasteFinished Structural LevelGranolithicHot PlateHardwoodHot Water UnitLaminate Finish

lvmdfmmcmrmrfmsmsbopglovpbdpcpconcplyrefRLrwhsscshshrskslrfspssststpvtctdtrttftphtrtrztvurvlwbwcwpmwrwrc

LouvreMed. Density FibreboardMirrorMetal CladdingMoisture ResistantMetal RoofingMild SteelMain SwitchboardOpaque GlazingOvenPlasterboardPolished ChromePolished ConcretePlywoodRefrigeratorReduced LevelRainwater HeadSinkSatin ChromeShadow LineShowerSkirtingSlate RoofingSet PlasterStainless SteelStoneStone PavingTerracottaTimber DeckingTerracotta Roof TilesTimber Strip FloorToilet Paper HolderTowel RailTerrazzoTimber Veneer (MDF)UrinalVinylWeatherboardWater ClosetWaterproofing MembraneWardrobeWestern Red Cedar

abbkhdbkpvbsnbwkcblkcbgcjcrcrtconccoscpcbdcptctdpdpcdwECLEFLEGLejFbwkfcFCLfgfgcFGLfhfhrFFLfwFSLgranohphwdhwulam

LEGEND

SCALE 1:50@A1

North Elevation-

01

SCALE 1:50@A1

West Elevation-

02

Page 10: Ground Floor Plan Roof Plan - live.ipcn.nsw.gov.au · pMrojeactcarthur Memorial Park Varroville Outbuildings 166-170 St Andrews Road Varroville wtewl. w+6.a1r c(h0)i2te c8t3u0ra3l

0 1 5m2 2.5

DEVELOPMENT APPLICATIONNOT FOR CONSTRUCTION

issue amendment date

drawing

scale drawn checked

Project No. revision

Electrical

Mechanical

Landscape

Hydraulic

Survey

Structural -

-

-

-

-

-

The contractor shall confirm on site existing dimensions and conditionsbefore commencement of works. All discrepancies should be reportedto the architect for instructions

Reproduction of this drawing is prohibited without the consent ofArchitectural Projects Pty. Ltd.

Architectural Projects does not accept responsibility for the dimensionalaccuracy of any data contained in CAD or other attachements as it maybe based on third party origin information. All information should beverified in writing.

This drawing has been prepared in conjunctionwith the following drawings:

Architectural Projects Pty. Ltd.©

project

Macarthur Memorial ParkVarroville Outbuildings166-170 St Andrews RoadVarroville

Former Coach House Elevations

1711 DA.104

plot date

25/8/17

File Path -/Volumes/Server Files/04. CAD/Current projects/1711 166-170 St Andrews Road Varoville/Client/166- 170 St Andrews Road Varoville MD B Action Conservation.pln

Gary O'Reilly - Registered Architect No. 4796

Architectural Projects Pty. Ltd.-, ABN 78 003 526 823architects@architectural projects.net.au -,www.architectural projects.net.authe Foundry.-, Studio 1 / 181 Lawson St, Darlington.-, NSW Australia 2008

drawing No.

xx1:50 @ A1@ A3-

GO

tel +61 (02) 8303 1700.-, fax +61(02) 9319 1128.-,

File Path -/Volumes/Server Files/04. CAD/Current projects/1711 166-170 St Andrews Road Varoville/Client/166- 170 St Andrews Road Varoville MD B Action Conservation.pln

Preliminary Issue 01 06 17-

Development Application 25 08 17A

A

Reconstruct existing roof framing of timber shinglesroofing to detailInstall new galvanised steel corrugated roofing

Repair existing pulley beam. Scarf newsection on to existing beam to match

Reconstruct existing timbercats head landing to matchexisting

WG01

C07C08C09C10C11

NOTES:

1. Conservation Works ScheduleThe conservation works schedule prepared by ArchitecturalProjects should be read in conjunction with these drawings

2. Existing Roof SheetingGenerally retain and protect existing roof sheeting "in situ" .Carefully inspect the roof space and identify areas required forrepairs. Replace and repair to match existing sheeting to achievea water proof roofing system as scheduledRemove all modern Tek-screws and washersRetain all existing traditional roof fixing and lead washersRetighten all existing fixings to be retained. Replace wheredamaged. Replace missing and damaged lead washersInstall new roof fixings to match existing where missing or fixingsare to be replaced

3. Existing Timber Shingle Roofing to G01-G03The original timber shingle roof remains extant under the existingcorrugated steel roofingRetain and protect the existing shingle roofing and prevent anydamage to the extant shinglesInspect the underside of the shingles from within the roof spacefor termite damage and active termites

8. Roof G04Collect all existing timber shingles that are currently on the groundCollect all loose existing timber shingles and store in palletslocated on site elevated on a temporary brickwork: Install a metalroof over the pallets which is fixed to the top of the pallet forprotection

Complete a photographic record of the existing roof framing andconnections to existing roof prior to commencing any work anduse for reference in reconstruction of roofCarefully remove existing timber rafters, which have collapsed.Remove existing attached shingles and store as aboveRemove existing battensAssess each rafter and retain those rafers in suitable conditionRafters not suitable for reuse due to termites or dry rot damageshall be retained for repairs. Store as directed

Reconstruct roof to G04 in accordance with spacing and detail ofexisting roof framing. Timber sizes to match exactly the sizes andprofiles of existing rafters . Timber species to match existingInstall new additional timber rafters to augment the existing roof inaccordance with engineer details.

Install new timber verandah beam to match existing (fragment)Install new timber columns C07-C11 to detailInstall additional beam at mid spam to augment existing roofframing in accordance with engineer details

Install brass plaque confirming reconstruction to details. Refer toConstruction Works Schedule

FFL+ 74.450 EFL

Retain and protect existing timber shingle roof asspecified

Lapped joint to new roof sheeting as specified

Reconstruct brick wall to support verandah beam

New timber columns and verandah beam to detail C07-C11

Install new galvanised steel ridge capping

Reconstruct brick wall to supportverandah beam

Install new roof sheeting as specified

Reconstruct timber shingles roof under (dotted) to matchexisting

Reconstruct timber shingles roofunder (dotted) to match existing

mrf

mrf

dp dp

fbk-ex fbk-ex

AD.01

FFL+ 74.450 EFL

Repair existing pulley beam. Scarfnew section on to existing beam tomatch

Reconstruct existingtimber cats headlanding to matchexisting

Reconstruct existingtimber cats head landingto match existing

Crack repair to engineerdetail

Remove existing steel plate and tension barand make good to existing wall and render

Reconstruct timber door reusing salvage timber boards from GW03

cr-ex cr-ex cr-ex

dp

dp

EXISTING BUILDING TO BE DEMOLISHED

REPLACE OR INFILL RENDER TO MATCHEXISTING APPROXIMATE ONLY TO BEDETERMINED ON SITE

CRACK REPAIR TO DETAIL

LEGEND

AdjustableBathBulkheadBrick PavingBasinBrickworkConcrete BlockworkColour backed glassControl JointCement RenderConcrete Roof TilesConcreteCheck On SiteChrome PlatedCupboardCarpetCeramic TilesDownpipeDamp Proof CourseDishwasherExisting Ceiling LevelExisting Floor LevelExisting Ground LineExpansion JointFace BrickworkFibre CementFinished Ceiling LevelFixed GlazingGel coated Fibre GlassFinished Ground LevelFire HydrantFire Hose ReelFinished Floor LevelFloor WasteFinished Structural LevelGranolithicHot PlateHardwoodHot Water UnitLaminate Finish

lvmdfmmcmrmrfmsmsbopglovpbdpcpconcplyrefRLrwhsscshshrskslrfspssststpvtctdtrttftphtrtrztvurvlwbwcwpmwrwrc

LouvreMed. Density FibreboardMirrorMetal CladdingMoisture ResistantMetal RoofingMild SteelMain SwitchboardOpaque GlazingOvenPlasterboardPolished ChromePolished ConcretePlywoodRefrigeratorReduced LevelRainwater HeadSinkSatin ChromeShadow LineShowerSkirtingSlate RoofingSet PlasterStainless SteelStoneStone PavingTerracottaTimber DeckingTerracotta Roof TilesTimber Strip FloorToilet Paper HolderTowel RailTerrazzoTimber Veneer (MDF)UrinalVinylWeatherboardWater ClosetWaterproofing MembraneWardrobeWestern Red Cedar

abbkhdbkpvbsnbwkcblkcbgcjcrcrtconccoscpcbdcptctdpdpcdwECLEFLEGLejFbwkfcFCLfgfgcFGLfhfhrFFLfwFSLgranohphwdhwulam

LEGEND

SCALE 1:50@A1

South Elevation-

01

SCALE 1:50@A1

East Elevation-

02

Page 11: Ground Floor Plan Roof Plan - live.ipcn.nsw.gov.au · pMrojeactcarthur Memorial Park Varroville Outbuildings 166-170 St Andrews Road Varroville wtewl. w+6.a1r c(h0)i2te c8t3u0ra3l

0 1 5m2 2.5

DEVELOPMENT APPLICATIONNOT FOR CONSTRUCTION

N

issue amendment date

drawing

scale drawn checked

Project No. revision

Electrical

Mechanical

Landscape

Hydraulic

Survey

Structural -

-

-

-

-

-

The contractor shall confirm on site existing dimensions and conditionsbefore commencement of works. All discrepancies should be reportedto the architect for instructions

Reproduction of this drawing is prohibited without the consent ofArchitectural Projects Pty. Ltd.

Architectural Projects does not accept responsibility for the dimensionalaccuracy of any data contained in CAD or other attachements as it maybe based on third party origin information. All information should beverified in writing.

This drawing has been prepared in conjunctionwith the following drawings:

Architectural Projects Pty. Ltd.©

project

Macarthur Memorial ParkVarroville Outbuildings166-170 St Andrews RoadVarroville

Cottage - Ground Floor Plan

1711

GO

DA.201

plot date

25/8/17

File Path -/Volumes/Server Files/04. CAD/Current projects/1711 166-170 St Andrews Road Varoville/Client/166- 170 St Andrews Road Varoville MD B Action Conservation.pln

Gary O'Reilly - Registered Architect No. 4796

Architectural Projects Pty. Ltd.-, ABN 78 003 526 823

tel +61 (02) 8303 1700.-, fax +61(02) 9319 1128.-,

architects@architectural projects.net.au -,www.architectural projects.net.authe Foundry.-, Studio 1 / 181 Lawson St, Darlington.-, NSW Australia 2008

drawing No.

TC1:50 @ A1@ A3-

File Path -/Volumes/Server Files/04. CAD/Current projects/1711 166-170 St Andrews Road Varoville/Client/166- 170 St Andrews Road Varoville MD B Action Conservation.pln

Preliminary Issue 01 06 17-

Development Application 25 08 17A

A

01W206

01W206

FFL + 74.590

Hanging beam 2/no (former tie beams paintedwhite)Remove and store for reinstatement to formerlocation

Demolish existing hot water tank

GW03GW02 GW01

GW04 GW05

GW06

GW

07GW08

GW09

GW10

G02G01

G03 G04 G05G06 G09

G08

G07

GD01

GD02

GD03 GD04 GD05

GD

06

GD07

GD08

GD09

GD10

GD11

NOTES:

1. Conservation Works ScheduleThe conservation works schedule prepared by ArchitecturalProjects should be read in conjunction with these drawings

2. Existing timber toungue and Ground floorRetain and protect existing timber flooring

3. Existing Floor CoveringRemove all existing floor coverings including smooth edge, nails,tracks and adhesive

4. Existing Wall LiningsRemove all existing internal hardboard or sheet linings includingany battens to walls to be retained. Take care not to damageexisting substrate (Plaster or framing)Retain and protect all existing timber board linings to room G04

5. Existing WallsDemolish existing walls noted for demolition. Take care whenremoving walls to not damage adjacent wall finishes.

6. Existing Ceiling LiningsDemolish all existing horizontal hardboard or similar sheet liningsTake care not to damage or remove existing ceiling roof tie beams(3no) framing to Dwelling 1

7. Ceiling FramingRemove all lower (horizontal) ceiling Joists to G02 & G03.

Remove all lower (horizontal) ceiling Joists to G01, G04, G05 &G06 only as nominated. Protect and retain existing ceiling framingnominated (evidence of white painted timber).

Remove and salvage 2/ no former ceiling framing roof tie beammembers utilised as hanging beams and store for reuse (evidenceof white painted timber)

8. Existing Roof FramingRetain and protect all existing roof framing including collar tiesand framing to roof ventilator

9. Existing Timber Boarded CeilingRetain and protect all existing timber boarded ceiling linings toroof space

10. Existing Timber Boarded WallRetain and protect all existing timber boarded walls includingthose boards to roof space between G02/G03 and G01/G04(above ceiling framing)

11. Roof VentilatorRetain and protect all framing , boarding, linings and louvres.

12. Existing Hot Water TankRemove existing hot water tank platform and all associatedservices from the roof space

13. Existing Water ServicesCarefully remove all internal services, pipes, conduct switch platesand cables equipment without damaging any adjacent finishes offabric or structure.

14. Existing WindowsRetain and protect window GW03 as an original window. andrepair as scheduled.Demolish existing windows GW01 and GW02Existing windows GW04 GW05 GW06 and GW07 to be retainedand repaired as scheduledRetain existing glass to windows sashes

15. Existing DoorsDemolish existing door leaf to GD01Demolish security door to GD01Demolish existing timber door to fireplace in room G01

EXISTING WALLS TOBE DEMOLISHED

EXISTING FLOORSTO BE DEMOLISHED

EXISTING CEILING LININGTO BE DEMOLISHED

LEGEND

GD12

EXISTING TIE BEAMS TO CEILINGSOVER TO BE RETAINED

EXISTING REGRADING OFEXISTING GROUND LEVEL ( APPROX.)

C1 C2 C3 C4 C5 C6

G10

GW11

DWELLING 2 DWELLING 1

Carefully remove existing concrete paving as theremay be evidence of original paving underneathseek instruction regarding paving once concrete pavinghas been removed

Demolish existing temporary timber columns toverandah . Salvage existing tuimber columns (paintedwhite) for reuseTemporary support verandah until column replacements

Demolish existing concrete slab

3/no existing tie beams to be retained inceiling (evidence of white paint)

Carefully remove existing infill boarding and framing toformer opening. Salvage and store safely external timberboards removed for potential maintenance works

New verandah beam over (dotted)

New timber columns to detail

GW12

Fall

Fall

Fall

tf-ex

tf-ex tf-ex

tf-ex

tf-ex

AdjustableBathBulkheadBrick PavingBasinBrickworkConcrete BlockworkColour backed glassControl JointCement RenderConcrete Roof TilesConcreteCheck On SiteChrome PlatedCupboardCarpetCeramic TilesDownpipeDamp Proof CourseDishwasherExisting Ceiling LevelExisting Floor LevelExisting Ground LineExpansion JointFace BrickworkFibre CementFinished Ceiling LevelFixed GlazingGel coated Fibre GlassFinished Ground LevelFire HydrantFire Hose ReelFinished Floor LevelFloor WasteFinished Structural LevelGranolithicHot PlateHardwoodHot Water UnitLaminate Finish

lvmdfmmcmrmrfmsmsbopglovpbdpcpconcplyrefRLrwhsscshshrskslrfspssststpvtctdtrttftphtrtrztvurvlwbwcwpmwrwrc

LouvreMed. Density FibreboardMirrorMetal CladdingMoisture ResistantMetal RoofingMild SteelMain SwitchboardOpaque GlazingOvenPlasterboardPolished ChromePolished ConcretePlywoodRefrigeratorReduced LevelRainwater HeadSinkSatin ChromeShadow LineShowerSkirtingSlate RoofingSet PlasterStainless SteelStoneStone PavingTerracottaTimber DeckingTerracotta Roof TilesTimber Strip FloorToilet Paper HolderTowel RailTerrazzoTimber Veneer (MDF)UrinalVinylWeatherboardWater ClosetWaterproofing MembraneWardrobeWestern Red Cedar

abbkhdbkpvbsnbwkcblkcbgcjcrcrtconccoscpcbdcptctdpdpcdwECLEFLEGLejFbwkfcFCLfgfgcFGLfhfhrFFLfwFSLgranohphwdhwulam

LEGEND

SCALE 1:50@A1

Ground Floor Demolition Plan-

01

Page 12: Ground Floor Plan Roof Plan - live.ipcn.nsw.gov.au · pMrojeactcarthur Memorial Park Varroville Outbuildings 166-170 St Andrews Road Varroville wtewl. w+6.a1r c(h0)i2te c8t3u0ra3l

0 1 5m2 2.5

DEVELOPMENT APPLICATIONNOT FOR CONSTRUCTION

N

issue amendment date

drawing

scale drawn checked

Project No. revision

Electrical

Mechanical

Landscape

Hydraulic

Survey

Structural -

-

-

-

-

-

The contractor shall confirm on site existing dimensions and conditionsbefore commencement of works. All discrepancies should be reportedto the architect for instructions

Reproduction of this drawing is prohibited without the consent ofArchitectural Projects Pty. Ltd.

Architectural Projects does not accept responsibility for the dimensionalaccuracy of any data contained in CAD or other attachements as it maybe based on third party origin information. All information should beverified in writing.

This drawing has been prepared in conjunctionwith the following drawings:

Architectural Projects Pty. Ltd.©

project

Macarthur Memorial ParkVarroville Outbuildings166-170 St Andrews RoadVarroville

Cottage - Roof Plan

1711

GO

W.202

plot date

25/8/17

File Path -/Volumes/Server Files/04. CAD/Current projects/1711 166-170 St Andrews Road Varoville/Client/166- 170 St Andrews Road Varoville MD B Action Conservation.pln

Gary O'Reilly - Registered Architect No. 4796

Architectural Projects Pty. Ltd.-, ABN 78 003 526 823

tel +61 (02) 8303 1700.-, fax +61(02) 9319 1128.-,

architects@architectural projects.net.au -,www.architectural projects.net.authe Foundry.-, Studio 1 / 181 Lawson St, Darlington.-, NSW Australia 2008

drawing No.

TC1:50 @ A1@ A3-

File Path -/Volumes/Server Files/04. CAD/Current projects/1711 166-170 St Andrews Road Varoville/Client/166- 170 St Andrews Road Varoville MD B Action Conservation.pln

Preliminary Issue 01 06 17-

Development Application 25 08 17A

A

01W206

01W206

Trim off folded roof flush with barge board and installnew galvanised edge roll to trim roofing

NOTES:

1. Conservation Works ScheduleThe conservation works schedule prepared by ArchitecturalProjects should be read in conjunction with these drawings

2. Existing Roof SheetingGenerally retain and protect existing roof sheeting "in situ" .Carefully inspect the roof space and identify areas required forrepairs. Replace and repair to match existing sheeting to achieve awater proof roofing system as scheduledRemove all modern Tek-screws and washersRetain all existing traditional roof fixings and lead washersRetighten all existing fixings to be retained. Replace wheredamaged. Replace missing and damaged lead washersInstall new roof fixings to match existing where missing or fixingsare to be replaced

3. Existing Timber Shingle RoofingThe original timber shingle roof remains extant under the existingcorrugated steel roofingRetain and protect the existing shingle roofing and prevent anydamage to the extant shinglesInspect the underside of the shingles from within the roof space fordry, rot, termite damage and active termites

4. Existing Flashingsinstall new lead soaker flashing for the chimney flueInspect all existing flashings and repair as required to matchexisting

5. GuttersReplace existing gutter with new galvanised ogee gutters. Installnew galvanised ogee gutter to the existing verandah

6. DownpipesInstall new 90mm OD galvanised downpipes as noted

7. Existing Fascias and Barge BoardsRemove and replace existing timber fascia and barge boardswith new barge boards as specified

8. Existing Roof VentilatorRemove corrugated roof sheeting to the vertical faces and salvagefor reuseRepair and make good to existing framing, cladding and louvres asrequired.Install new timber shingle roof to match existingInstall bronze insect mesh to the inside frame of the louvresReinstate corrugated steel roofing and capping: over timber shingleroofing

9. Existing Masonry WallsInstall a new damp proof course to the full depth of the brick wall toall masonry walls as specified. Damp proofing course to be installedimmediately above the timber flooring

DEMOLISH EXISTING ROOF

REMOVE EXISTING ROOF SHEETING AND SALVAGE

AREA OF SPECIFIC REPAIRS TO EXISTING ROOF SHEETING

LEGEND

EXISTING BUILDING DEMOLISHED

Install new galvanised ogee gutter as specified toexisting verandah

Install new lead soaker flashing to existing chimney flue

Remove existing ridge capping and replace to matchexisting

Remove existing edge cappingInstall new galvanised edge roll to trim existing roofing

Remove and replace existing gutter with new galvanisedogee gutter as specified

Replace existing timber fascia as specified

Remove existing roofing and capping and salvage forre-installationInstall new timber shingle roof to match existingRe install existing corrugated sheet roofing and cappingto match existing prior to removal

Remove existing edge cappingInstall new galvanised edge roll to trim existing roofing

Replace existing barge boards as specified

Existing lapped joints in corrugated steel roofing to beretained

Install new timberbarge boards asspecified . Installnew existing edgeroll to trim existingroofing

Replace existing timber barge boards as specifiedand install new edge rolls as specified

mrf-ex

mrf-ex

mrf-ex

mrf-ex

mrf-ex

mrf-ex

AdjustableBathBulkheadBrick PavingBasinBrickworkConcrete BlockworkColour backed glassControl JointCement RenderConcrete Roof TilesConcreteCheck On SiteChrome PlatedCupboardCarpetCeramic TilesDownpipeDamp Proof CourseDishwasherExisting Ceiling LevelExisting Floor LevelExisting Ground LineExpansion JointFace BrickworkFibre CementFinished Ceiling LevelFixed GlazingGel coated Fibre GlassFinished Ground LevelFire HydrantFire Hose ReelFinished Floor LevelFloor WasteFinished Structural LevelGranolithicHot PlateHardwoodHot Water UnitLaminate Finish

lvmdfmmcmrmrfmsmsbopglovpbdpcpconcplyrefRLrwhsscshshrskslrfspssststpvtctdtrttftphtrtrztvurvlwbwcwpmwrwrc

LouvreMed. Density FibreboardMirrorMetal CladdingMoisture ResistantMetal RoofingMild SteelMain SwitchboardOpaque GlazingOvenPlasterboardPolished ChromePolished ConcretePlywoodRefrigeratorReduced LevelRainwater HeadSinkSatin ChromeShadow LineShowerSkirtingSlate RoofingSet PlasterStainless SteelStoneStone PavingTerracottaTimber DeckingTerracotta Roof TilesTimber Strip FloorToilet Paper HolderTowel RailTerrazzoTimber Veneer (MDF)UrinalVinylWeatherboardWater ClosetWaterproofing MembraneWardrobeWestern Red Cedar

abbkhdbkpvbsnbwkcblkcbgcjcrcrtconccoscpcbdcptctdpdpcdwECLEFLEGLejFbwkfcFCLfgfgcFGLfhfhrFFLfwFSLgranohphwdhwulam

LEGEND

SCALE 1:50@A1

Roof Plan-

01

LEGEND

Page 13: Ground Floor Plan Roof Plan - live.ipcn.nsw.gov.au · pMrojeactcarthur Memorial Park Varroville Outbuildings 166-170 St Andrews Road Varroville wtewl. w+6.a1r c(h0)i2te c8t3u0ra3l

0 1 5m2 2.5

DEVELOPMENT APPLICATIONNOT FOR CONSTRUCTION

issue amendment date

drawing

scale drawn checked

Project No. revision

Electrical

Mechanical

Landscape

Hydraulic

Survey

Structural -

-

-

-

-

-

The contractor shall confirm on site existing dimensions and conditionsbefore commencement of works. All discrepancies should be reportedto the architect for instructions

Reproduction of this drawing is prohibited without the consent ofArchitectural Projects Pty. Ltd.

Architectural Projects does not accept responsibility for the dimensionalaccuracy of any data contained in CAD or other attachements as it maybe based on third party origin information. All information should beverified in writing.

This drawing has been prepared in conjunctionwith the following drawings:

Architectural Projects Pty. Ltd.©

project

Macarthur Memorial ParkVarroville Outbuildings166-170 St Andrews RoadVarroville

Cottage - Elevations

1711 W.203

plot date

25/8/17

File Path -/Volumes/Server Files/04. CAD/Current projects/1711 166-170 St Andrews Road Varoville/Client/166- 170 St Andrews Road Varoville MD B Action Conservation.pln

Gary O'Reilly - Registered Architect No. 4796

Architectural Projects Pty. Ltd.-, ABN 78 003 526 823architects@architectural projects.net.au -,www.architectural projects.net.authe Foundry.-, Studio 1 / 181 Lawson St, Darlington.-, NSW Australia 2008

drawing No.

xx1:50 @ A1@ A3-

GO

tel +61 (02) 8303 1700.-, fax +61(02) 9319 1128.-,

File Path -/Volumes/Server Files/04. CAD/Current projects/1711 166-170 St Andrews Road Varoville/Client/166- 170 St Andrews Road Varoville MD B Action Conservation.pln

Preliminary Issue 01 06 17-

Development Application 25 08 17A

A

Remove existing temporary columnRetain existing timber column scarf a newlower section to the column (to match theexisting ) with new concealed galvanisedstirrup to detail (typical)

Retain existing timber boardingto roof ventilator

Remove existing capping to existing barge boardInstall new barge board and galvanised edge rollas specified

mrf-ex

FFL + 74.59 EFL

Infill render to detail Crack repair to existingrender to engineer detail

Demolish existing electricalcabinet and condiuitsMake good to existing render

Existing ground line (dotted) New ground line

Remove existing roofing and capping and salvage forre-installationInstall new timber shingles roofing to match existing .Re-install existing corrugated steel roof and capping tomatch existing prior to removal

Demolish existing buildings

New timber boards to match existing toverandah ends

Repair /replace existing timbercolumns as specified

cf-ex

cf-ex

cf-ex

cf-ex

wb-ex

wb

dp

Fall

Fall

dp

RL + 74.59

Remove existing corrugated steel cladding to roofSalvage for future use

Demolish existing metal panelbox

Remove any existing door andinstall new door to detail

Remove existing sheet nailedto verandah beam and makegood

New lead soaker flashing tochimney flue

Carefully remove existing infillboard and framing to formopening Install new timberdoor to detail

Regrade existing ground levelto be a minimum of 200 mmbelow existing floor level withfalls away from the building

existing ground line (dotted)

New ground line

Demolish existing non- original addition to chimney flueSupply and install a lead capping to the fireplace flue

New lead capping to existingchimney flue

NOTES:1. Conservation Works ScheduleThe conservation works schedule prepared by ArchitecturalProjects should be read in conjunction with these drawings

2. Existing servicesRemove all existing services to exterior of the building and makegood.

3. Roof VentilatorRemove corrugated roof sheeting to the vertical faces and salvagefor reuseRepair and make good to existing framing, cladding and louvresas required.Install new timber shingle roof to match existingInstall bronze insect mesh to the inside frame of the louvresReinstate corrugated steel roofing and capping: over timbershingle roofing

4. Existing Roof SheetingGenerally retain and protect existing roof sheeting "in situ" .Carefully inspect the roof space and identify areas required forrepairs. Replace and repair to match existing sheeting to achievea water proof roofing system as scheduledRemove all modern Tek-screws and washersRetain all existing traditional roof fixings and lead washersRetighten all existing fixings to be retained. Replace wheredamaged. Replace missing and damaged lead washersInstall new roof fixings to match existing where missing or fixingsare to be replaced

5. Existing Timber Shingle RoofingThe original timber shingle roof remains extant under the existingcorrugated steel roofingRetain and protect the existing shingle roofing and prevent anydamage to the extant shinglesInspect the underside of the shingles from within the roof spacefor dry, rot, termite damage and active termites

6. Existing External RenderExisting building has been cement renderedHack off existing loose and rummy render. Clean down whererender has been removed or is missing to remove any dust looseor organic materialInstall new render to match the existing render materialcomposition, strength, texture and finish

7. Existing External Timber WeatherboardsGenerally repair all existing external timber weatherboardsWhere possible retain and repair with splice joints or similarmethods with new sections to match.Where replacement is required replace to match existing timberspecies or as approvedReplace profile with a profile that is similar but distinguishablefrom the original (to approved detail) on close inspectionGroup together existing and new boards . New boards should belocated in a group at the bottom of the wall where possible orexcept as noted.

GW01 GW02 GW03

GD12

GW03GW02GW01 GD01

FFL + 74.59 EFL

Remove existing roofing and capping and salvage forre-installationInstall new timber shingles roofing to match existing .Re-install existing corrugated steel roof and capping tomatch existing prior to removal

Remove and replace existing ridge capping with newgalvanised capping as specified

Infill render to be detailed

Infill render to detail

mrf-ex

cr-ex

cr-exwb-ex wb-ex wb-ex

mrf-ex

mrf-ex

mrf-ex

cr-ex

GW10

GW11

dp

wb-exwb-ex

wb-ex

AdjustableBathBulkheadBrick PavingBasinBrickworkConcrete BlockworkColour backed glassControl JointCement RenderConcrete Roof TilesConcreteCheck On SiteChrome PlatedCupboardCarpetCeramic TilesDownpipeDamp Proof CourseDishwasherExisting Ceiling LevelExisting Floor LevelExisting Ground LineExpansion JointFace BrickworkFibre CementFinished Ceiling LevelFixed GlazingGel coated Fibre GlassFinished Ground LevelFire HydrantFire Hose ReelFinished Floor LevelFloor WasteFinished Structural LevelGranolithicHot PlateHardwoodHot Water UnitLaminate Finish

lvmdfmmcmrmrfmsmsbopglovpbdpcpconcplyrefRLrwhsscshshrskslrfspssststpvtctdtrttftphtrtrztvurvlwbwcwpmwrwrc

LouvreMed. Density FibreboardMirrorMetal CladdingMoisture ResistantMetal RoofingMild SteelMain SwitchboardOpaque GlazingOvenPlasterboardPolished ChromePolished ConcretePlywoodRefrigeratorReduced LevelRainwater HeadSinkSatin ChromeShadow LineShowerSkirtingSlate RoofingSet PlasterStainless SteelStoneStone PavingTerracottaTimber DeckingTerracotta Roof TilesTimber Strip FloorToilet Paper HolderTowel RailTerrazzoTimber Veneer (MDF)UrinalVinylWeatherboardWater ClosetWaterproofing MembraneWardrobeWestern Red Cedar

abbkhdbkpvbsnbwkcblkcbgcjcrcrtconccoscpcbdcptctdpdpcdwECLEFLEGLejFbwkfcFCLfgfgcFGLfhfhrFFLfwFSLgranohphwdhwulam

LEGEND

EXISTING BUILDING TO BE DEMOLISHED

REPLACE OR INFILL RENDER TO MATCHEXISTING APPROXIMATE ONLY TO BEDETERMINED ON SITE

CRACK REPAIR TO DETAIL

LEGEND

SCALE 1:50@A1

West Elevation-

01

SCALE 1:50@A1

North Elevation-

01

Page 14: Ground Floor Plan Roof Plan - live.ipcn.nsw.gov.au · pMrojeactcarthur Memorial Park Varroville Outbuildings 166-170 St Andrews Road Varroville wtewl. w+6.a1r c(h0)i2te c8t3u0ra3l

0 1 5m2 2.5

DEVELOPMENT APPLICATIONNOT FOR CONSTRUCTION

issue amendment date

drawing

scale drawn checked

Project No. revision

Electrical

Mechanical

Landscape

Hydraulic

Survey

Structural -

-

-

-

-

-

The contractor shall confirm on site existing dimensions and conditionsbefore commencement of works. All discrepancies should be reportedto the architect for instructions

Reproduction of this drawing is prohibited without the consent ofArchitectural Projects Pty. Ltd.

Architectural Projects does not accept responsibility for the dimensionalaccuracy of any data contained in CAD or other attachements as it maybe based on third party origin information. All information should beverified in writing.

This drawing has been prepared in conjunctionwith the following drawings:

Architectural Projects Pty. Ltd.©

project

Macarthur Memorial ParkVarroville Outbuildings166-170 St Andrews RoadVarroville

Cottage - Elevations

1711 W.204

plot date

25/8/17

File Path -/Volumes/Server Files/04. CAD/Current projects/1711 166-170 St Andrews Road Varoville/Client/166- 170 St Andrews Road Varoville MD B Action Conservation.pln

Gary O'Reilly - Registered Architect No. 4796

Architectural Projects Pty. Ltd.-, ABN 78 003 526 823architects@architectural projects.net.au -,www.architectural projects.net.authe Foundry.-, Studio 1 / 181 Lawson St, Darlington.-, NSW Australia 2008

drawing No.

xx1:50 @ A1@ A3-

GO

tel +61 (02) 8303 1700.-, fax +61(02) 9319 1128.-,

File Path -/Volumes/Server Files/04. CAD/Current projects/1711 166-170 St Andrews Road Varoville/Client/166- 170 St Andrews Road Varoville MD B Action Conservation.pln

Preliminary Issue 01 06 17-

Development Application 25 08 17A

A

GD09

RL + 74.320

Remove and replace existing ridge capping as specified

New lead soaker flashing to chimney flue

Demolish existing non- original addition to chimney flueSupply and install a lead capping to the chimney flue

Remove existing corrugated steel cladding to roofventilatorSalvage for future use

Retain and protect existing corrugated steel roofing

Install new lead capping to chimney flue

Demolish existing additions (dotted)

NOTES:

1. Conservation Works ScheduleThe conservation works schedule prepared by ArchitecturalProjects should be read in conjunction with these drawings

2. Existing ServicesRemove all existing services to exterior of the building and makegood.

3. Existing Roof VentilatorRemove corrugated roof sheeting to the vertical faces and salvagefor reuseRepair and make good to existing framing, cladding and louvresas required.Install new timber shingle roof to match existingInstall bronze insect mesh to the inside frame of the louvresReinstate corrugated steel roofing and capping: over timbershingle roofing

4. Existing Roof SheetingGenerally retain and protect existing roof sheeting "in situ" .Carefully inspect the roof space and identify areas required forrepairs. Replace and repair to match existing sheeting to achievea water proof roofing system.Remove all modern Tek-screws and washersRetain all existing traditional roof fixings and lead washersRetighten all existing fixing to be retained. Replace wheredamaged. Replace missing and damaged lead washersInstall new roof fixings to match existing where missing or fixingsare to be replaced

5. Existing Timber Shingle Roofing.The original timber shingle roof remains extant under the existingcorrugated steel roofingRetain and protect the existing shingle roofing and prevent anydamage to the extant shinglesInspect the underside of the shingles form with the roof space fordry, rot, termites damage and active termites

6. Existing External RenderExisting building has been cement rendered removedHack off existing loose and rummy render. Clean down whererender has been removed or is missing to remove any dust looseor organic materialInstall new render to match the existing render materialcomposition, strength, texture and finish

7. Existing External Timber WeatherboardsGenerally repair all existing external timber weatherboardsWhere possible retain and repair with splice joints or similarmethods with new sections to match.Where replacement is required replace to match existing timberspecies or as approvedReplace profile with a profile that is similar but distinguishablefrom the original (to approved detail) on close inspectionGroup together existing and new boards . New boards should belocated in a group at the bottom of the wall where possible orexcept as noted.

FFL + 74.59EFL

GW06

Remove sections of deteriorated external timberboarding . Remove sections of loose white boarding .Re-fix loose boardingInstall new timber boarding to match existing

Vertical joint between new and existing timber boards

Reconstruct timber framing to match existingInstall new external timber boarding to match existing

Demolish existing hot water tank platform and makegood

Remove existing roofing and capping and savage forre-installationInstall new timber shingles roofing to match existing .Re-install existing corrugated steel roof and capping tomatch existing prior to removalRepair existing framing , weatherboards and louvres for

ventilation as specified

Replace....

Demolish existing additions (dotted)

New infill framing ... weatherboards to match existing

New ground line

Demolish existingconcrete slab

Existing ground line

wb-ex

cr-ex

GW04

cr-ex

GW05 GW07

GD08

GW08

wb-ex wb wb

mrf-ex

mrf-ex

cr-ex

cr-ex

Remove existing capping to existing barge boardInstall new barge board and galvanised edge roll asspecified

Demolish existing non- original addition to chimney flueSupply and install a led capping to the fireplace flue

Remove existing corrugated steel cladding to roofSalvage for future use

Remove existing temporarycolumnRetain existing timber columnand scarf a new lower sectionto the column (to the column(to match the existing ) withnew concealed galvanisedstirrup to detail (typical)

EFLFFL + 74.59

Demolish existing additions(dotted)

New galvanised ogee gutter as specified

Infill render to detail

Crack repair to detail

New galvanised ogeegutter as specified

Remove existing roofing and capping and salvage forre-installationInstall new timber shingles roofing to match existing .Re-install existing corrugated steel roof and capping tomatch existing prior to removal

Repair existing framing , weatherboards and louvres forventilation as specified

cr-ex

cr-ex

GW09

wb-ex

cr-ex cr-ex

AdjustableBathBulkheadBrick PavingBasinBrickworkConcrete BlockworkColour backed glassControl JointCement RenderConcrete Roof TilesConcreteCheck On SiteChrome PlatedCupboardCarpetCeramic TilesDownpipeDamp Proof CourseDishwasherExisting Ceiling LevelExisting Floor LevelExisting Ground LineExpansion JointFace BrickworkFibre CementFinished Ceiling LevelFixed GlazingGel coated Fibre GlassFinished Ground LevelFire HydrantFire Hose ReelFinished Floor LevelFloor WasteFinished Structural LevelGranolithicHot PlateHardwoodHot Water UnitLaminate Finish

lvmdfmmcmrmrfmsmsbopglovpbdpcpconcplyrefRLrwhsscshshrskslrfspssststpvtctdtrttftphtrtrztvurvlwbwcwpmwrwrc

LouvreMed. Density FibreboardMirrorMetal CladdingMoisture ResistantMetal RoofingMild SteelMain SwitchboardOpaque GlazingOvenPlasterboardPolished ChromePolished ConcretePlywoodRefrigeratorReduced LevelRainwater HeadSinkSatin ChromeShadow LineShowerSkirtingSlate RoofingSet PlasterStainless SteelStoneStone PavingTerracottaTimber DeckingTerracotta Roof TilesTimber Strip FloorToilet Paper HolderTowel RailTerrazzoTimber Veneer (MDF)UrinalVinylWeatherboardWater ClosetWaterproofing MembraneWardrobeWestern Red Cedar

abbkhdbkpvbsnbwkcblkcbgcjcrcrtconccoscpcbdcptctdpdpcdwECLEFLEGLejFbwkfcFCLfgfgcFGLfhfhrFFLfwFSLgranohphwdhwulam

LEGEND

EXISTING BUILDING TO BE DEMOLISHED

REPLACE OR INFILL RENDER TO MATCHEXISTING APPROXIMATE ONLY TO BEDETERMINED ON SITE

CRACK REPAIR TO DETAIL

LEGEND

SCALE 1:50@A1

South Elevation-

01

SCALE 1:50@A1

East Elevation-

01

Page 15: Ground Floor Plan Roof Plan - live.ipcn.nsw.gov.au · pMrojeactcarthur Memorial Park Varroville Outbuildings 166-170 St Andrews Road Varroville wtewl. w+6.a1r c(h0)i2te c8t3u0ra3l

0 1 5m2 2.5

DEVELOPMENT APPLICATIONNOT FOR CONSTRUCTION

issue amendment date

drawing

scale drawn checked

Project No. revision

Electrical

Mechanical

Landscape

Hydraulic

Survey

Structural -

-

-

-

-

-

The contractor shall confirm on site existing dimensions and conditionsbefore commencement of works. All discrepancies should be reportedto the architect for instructions

Reproduction of this drawing is prohibited without the consent ofArchitectural Projects Pty. Ltd.

Architectural Projects does not accept responsibility for the dimensionalaccuracy of any data contained in CAD or other attachements as it maybe based on third party origin information. All information should beverified in writing.

This drawing has been prepared in conjunctionwith the following drawings:

Architectural Projects Pty. Ltd.©

project

Macarthur Memorial ParkVarroville Outbuildings166-170 St Andrews RoadVarroville

Cottage - Section 2

1711 W.205

plot date

25/8/17

File Path -/Volumes/Server Files/04. CAD/Current projects/1711 166-170 St Andrews Road Varoville/Client/166- 170 St Andrews Road Varoville MD B Action Conservation.pln

Gary O'Reilly - Registered Architect No. 4796

Architectural Projects Pty. Ltd.-, ABN 78 003 526 823architects@architectural projects.net.au -,www.architectural projects.net.authe Foundry.-, Studio 1 / 181 Lawson St, Darlington.-, NSW Australia 2008

drawing No.

xx1:20,1:50 @ A1

@ A3-GO

tel +61 (02) 8303 1700.-, fax +61(02) 9319 1128.-,

File Path -/Volumes/Server Files/04. CAD/Current projects/1711 166-170 St Andrews Road Varoville/Client/166- 170 St Andrews Road Varoville MD B Action Conservation.pln

Preliminary Issue 01 06 17-

Development Application 25 08 17A

A

Retain and repair as required existing roof ventilatorframing, cladding and louvres as scheduled

Retain and repair as required any existing roof framingto match existing

Demolish existing walls and roof

Remove existing corrugated sheeting roof lanternsalvage for future use

Infill timber ceiling boards around existing tiebeamReinstate 2/no tie beams where missing tomatch the existing

Retain and protect existing roof sheeting and timbershingle roofing under rafter

Existing ground level

Regrade existingground level hereaway from thebuilding

Remove existing walllinings

Retain and protectexisting 3/no roof tiebeams install 2/no ofsalvage tie beamsand infill ceilinglining boards aroundbeam ends

Demolish existingfalse ceiling andframing

Remove all cementrender and replasterwall with lime renderas specified

Existing liningdemolished Installnew timber liningboard as specifiedInstall wall insulationprior to lining wall

New removable hatch to ceiling as specifiedNew trim to existing opening to ceiling / ventilator

Re instate existing timber lining boards loose inceiling frame to former location

Carefully remove 2/ no former roof tie beams andreinstate to former location to detail confirm onsite

Repair timber verandah framing as specified

New ogee gutter as specified

Existing ground level

Retain and protect existing timber lining boards to faceceiling

New timber column as scheduled

Regrade existingground level hereaway from thebuilding

tf-ex tf-ex

wb-ex

NOTES:

1. Conservation Works ScheduleThe conservation works schedule prepared by ArchitecturalProjects should be read in conjunction with these drawings

2. Existing Roof SheetingGenerally retain and protect existing roof sheeting "in situ" .Carefully inspect the roof space and identify areas required forrepairs. Replace and repair to match existing sheeting to achievea water proof roofing system.Remove all modern Tek-screws and washersRetain all existing traditional roof fixing screws and lead washersRetighten all existing fixing to be retained. Replace wheredamaged. Replace missing and damaged lead washersInstall new roof fixings to match existing where missing or fixingsare to be replaced

3. Existing Timber Shingle Roofing.The original timber shingle roof remains extant under the existingcorrugated steel roofingRetain and protect the existing shingle roofing and prevent anydamage to the extant shinglesInspect the underside of the shingles form with the roof space fordry, rot, termites damage and active termitesSeek instructions from heritage architect if damage found as towork required

4. Existing Roof VentilatorRemove corrugated roof sheeting to the vertical faces and salvagefor reuseRepair and make good to existing framing, cladding and louvresas required.Install new timber shingle roof to match existingInstall bronze insect mesh to the inside frame of the louvresReinstate corrugated steel roofing and capping: over timbershingle roofing

5. Existing servicesRemove all existing services to exterior architrave of the buildingand make good.

DGD02

G01

EFL

Remove existing wall linings and make good to existingframing as specified

Infill missing timber boarding to match existing fromloose boards in ceiling with new boards as required

Infill timber ceiling boards around existing andreinstate the beams where missing to matchthe existing

Remove existing roofing and capping and salvage forre-installationInstall new timber shingle roof to match existingReinstall existing corrugated sheet roofing and cappingto match existing prior to removal

Lower existing groundlevel below timberfloor/ framing wherepossible to improveclearence andsubfloor ventilation

Demolish existing wall

Replace DG02 andframe as scheduled

wb-ex

tb-ex tb-ex

tb-ex tb-ex

tb-ex

tb-ex

AdjustableBathBulkheadBrick PavingBasinBrickworkConcrete BlockworkColour backed glassControl JointCement RenderConcrete Roof TilesConcreteCheck On SiteChrome PlatedCupboardCarpetCeramic TilesDownpipeDamp Proof CourseDishwasherExisting Ceiling LevelExisting Floor LevelExisting Ground LineExpansion JointFace BrickworkFibre CementFinished Ceiling LevelFixed GlazingGel coated Fibre GlassFinished Ground LevelFire HydrantFire Hose ReelFinished Floor LevelFloor WasteFinished Structural LevelGranolithicHot PlateHardwoodHot Water UnitLaminate Finish

lvmdfmmcmrmrfmsmsbopglovpbdpcpconcplyrefRLrwhsscshshrskslrfspssststpvtctdtrttftphtrtrztvurvlwbwcwpmwrwrc

LouvreMed. Density FibreboardMirrorMetal CladdingMoisture ResistantMetal RoofingMild SteelMain SwitchboardOpaque GlazingOvenPlasterboardPolished ChromePolished ConcretePlywoodRefrigeratorReduced LevelRainwater HeadSinkSatin ChromeShadow LineShowerSkirtingSlate RoofingSet PlasterStainless SteelStoneStone PavingTerracottaTimber DeckingTerracotta Roof TilesTimber Strip FloorToilet Paper HolderTowel RailTerrazzoTimber Veneer (MDF)UrinalVinylWeatherboardWater ClosetWaterproofing MembraneWardrobeWestern Red Cedar

abbkhdbkpvbsnbwkcblkcbgcjcrcrtconccoscpcbdcptctdpdpcdwECLEFLEGLejFbwkfcFCLfgfgcFGLfhfhrFFLfwFSLgranohphwdhwulam

LEGEND

SCALE 1:20@A1

SectionW20101