Product information Computer Controlled Measurement Amplifiers
1pi-F2-messverstaerker_e V1.55-00
GHM Messtechnik GmbH – Sales Center InternationalSchloßstraße 6 88453 Erolzheim Germany Fon +49-7354-937233-0 Fax -88www.ghm-messtechnik.de [email protected]
Product Information Test Bench Measurement
Computer Controlled Measurement Amplifiers
FeaturesSystem Digital signal processing
Digital signal conditioningSources Strain gauge bridges
Current, voltage signalsPotentiometerShunt sensorsThermocouplesPt100 resistorsICP® sensorsFrequencySpeed, pulsesDigital Outputs
Applications Industrial measurement and con-
troltechnology
Test bench measurement
Mobile measurement
Signal conditioning
Signal filtering
Signal acquisition
pi-F2-messverstaerker_e V1.55-00
1
GHM GROUP CORPORATE | GHM Messtechnik GmbHSchloßstr. 6 | 88453 Erolzheim | GERMANYPhone +49 7354 937233-76 | Fax +49 7354 937233-88www.ghm-group.de | [email protected]
Product information Computer Controlled Measurement Amplifiers
2 pi-F2-messverstaerker_e V1.55-00
GHM Messtechnik GmbH – Sales Center InternationalSchloßstraße 6 88453 Erolzheim Germany Fon +49-7354-937233-0 Fax -88www.ghm-messtechnik.de [email protected]
Product Information Test Bench Measurement
Functions and BenefitsThe amplifiers are developed for the various sensorsin test benches of the automotive industry, machinemanufacturing and installation, research and develop-ment. They offer sensor excitation, isolation, signalconditioning, analog and/or digital data acquisitionwith highest precision. A CAN Interface unit serves for synchronous acquisi-tion of messages from CAN bus. These are availableon the internal bus and can be processed togetherwith the other measurement data by the acquisitionsoftware. Each unit has two independent CAN nodestransmitting 24 values in different formats at 16 biteach synchronously. They can be grouped in differentdata types. Both nodes can be switched together. Abus termination is switched in by the parameter set-ting software. A DIO plug-in unit is available for 8 digital input sig-nals (e.g. logical states) with an output of switchingsignals by relays. An extended version provides ac-quisition of signals from frequency generators and in-cremental encoders .The AO unit supplies adjustable voltages up to±10 V .
All standard 19“ chassis are laid out for either mobile(DC supply 9 - 36 V) or stationary use (AC supply 110- 230 V). They have an Ethernet interface for data ac-quisition and parameter setting, as well as a CANsocket for access to a CAN bus. Parameter setting ofthe amplifiers can also be done via a serial (RS 232 /RS 485) interface. Several chassis can be interlinkedsynchronously by the Ethernet interface to up to 600channels. There are 2 to 16 amplifier bays availablefor both systems in one 19“ desktop-housing or 84 Urack. Especially designed for distributed applications and/ora few channels, the SIQUAD line offers compact mod-ules and miniature systems with 1, 2 or 3 amplifierunits, as well as 1- or 2-channel DIN-rail modules.
Data acquisition can be simply done already via theCAN interface with a suitable data logger. Via the Eth-ernet interface comfortable data acquisition and on-line visualization of measurement data can be per-formed PC-based with DAQSoft. Drivers for othermeasurement software like DASYLab and LabVIEWare optional available.
Amplifier / System DASIM SIQUADChannels / amplifierChannels / 19“ chassis
2up to 32
1, 2, 4, (8)up to 64 (128)
Sample rate / channelSample rate / chassis
1 Hz – 20 kHz, 1 Hz – 40 kHzapprox. 500 kS/s
1 Hz – 20 kHzapprox. 500 kS/s
Sensor connection Lemo sockets chassis back panel Various sockets amplifier front panel
Universal amplifier Strain gauge full/half (quarter) bridge;DC voltage, current; thermocouples J, K,etc.; Pt100; frequency analog; frequencydigital; incremental encoder; PCM;torque; ICP©
Strain gauge full/half (quarter) bridge;DC voltage, current; thermocouples J, K,etc.; Pt100; frequency analog; frequencydigital; incremental encoder; PCM;torque; ICP©
CF amplifier 5 kHz Strain gauge, LVDT, torque ---
AD conversion 16 bit 24 bit
Modular amplifiers ------------------
DIO (8 I, 8 O) (front panel)AO (4x ± 10 V) (front panel)
Strain gauge full/half (quarter) bridgeDC voltage, currentElectric powerThermocouples J, K, etc.Pt100Frequency digital; incremental encoderICP©
DIO (8 I, 8 O), AO (4x ± 10 V)
CAN interface unit 2 CAN nodes (front panel) 2 CAN nodes
Interfaces RS 232, CAN, Ethernet RS 232, CAN, Ethernet
Data output CAN, Ethernet, ± 10 V CAN, Ethernet, (optional ± 10 V)
2 pi-F2-messverstaerker_e V1.55-00
GHM GROUP CORPORATE | GHM Messtechnik GmbHSchloßstr. 6 | 88453 Erolzheim | GERMANYPhone +49 7354 937233-76 | Fax +49 7354 937233-88www.ghm-group.de | [email protected]
Product information Computer Controlled Measurement Amplifiers
3pi-F2-messverstaerker_e V1.55-00
GHM Messtechnik GmbH – Sales Center InternationalSchloßstraße 6 88453 Erolzheim Germany Fon +49-7354-937233-0 Fax -88www.ghm-messtechnik.de [email protected]
Product Information Test Bench Measurement
Device OverviewAmplifier Input Output
Page
Sens
or
Stra
in g
auge
Volta
ge
Hig
h vo
ltage
(Sig
nal)
Cur
rent
Elec
tric
Pow
er
Pote
ntio
met
er
Ther
moc
oupl
es
Pt10
0
ICP®
Torq
ue (D
iscr
im.)
Freq
uenc
y an
alog
Freq
uenc
y di
gita
l
PWM
Indu
ctiv
e se
nsor
s
± 10
V
Ethe
rnet
CA
N
DASIM Uni2 4
DASIM TF2 5
SIQUAD Uni4 6
SIQUAD DMS4 7
SIQUAD DC 9
SIQUAD DC2HV 10
SIQUAD Poti4 12
SIQUAD TC 13
SIQUAD Pt100 14
SIQUAD ICP4 15
SIQUAD FU2 16
DIO8 17
AO4 17
CAN Interface 18
Central Unit, Parameter Setting Software DaSoft 19
Data Acquisition Software (DASIM-SW-DAQSoft, SIQUAD-SW-DAQSoft, Drivers) 20
System Chassis and Housings (DASIM-G, SIQUAD-GD) 21
SCC Uni4 22
SCC Modules 23
TSC Uni 25
SCC Uni1 26
SEC Uni4 27
SEC Modules 30
ADETH 31
Standard, Optional, per type of sensor, technical specifications subject to change without notice.
pi-F2-messverstaerker_e V1.55-00
3
GHM GROUP - Standort Imtron | GHM Messtechnik GmbHCarl-Benz-Straße 11 | 88696 Owingen | GERMANYPhone +49 7551 9290-0 | Fax +49 7551 9290-90www.ghm-group.de | [email protected]
Product information Computer Controlled Measurement Amplifiers
4 pi-F2-messverstaerker_e V1.55-00
GHM Messtechnik GmbH - Location IMTRONCarl-Benz-Str. 11 D-88696 Owingen Germany Fon +49(0)7551/9290-0 Fax -90www.ghm-messtechnik.de [email protected] Controlled Measurement Amplifiers Test Bench Measurement
DASIM Uni2CharacteristicsThe DASIM Universal Amplifier offers computer-controlledsignal conditioning of manifold sensors. It has 1 DSP perchannel. Signal output is with high precision via analog out-puts and digitally via Ethernet and CAN. Parameter settingis done with the software DaSoft. Signal filtering can beconfigured from 3..3000 resp. 6..6000 Hz at 20 resp.40 kS/s sample rate.
Technical Data
General
Accuracy see sensorsChannels/unit 2, isolatedSample rate 20 kHz / 40 kHz
Band width 5 kHz / max. 15 kHz(analog sensors)
Analog output± 10 V / 12 mA (short proof)2 outputs/channel16 bit resolution
Digital output SPI (internal), CANInput protection ± 100 V, ESD IEC 1000-4-2
Supply voltage+15 V / 65 mA-15 V / 60 mA+5 V / 320 mA
Environmentaltemperature 0..+50 °C
Strain gaugebridges
Range 0.5, 1, 2, 4, 5, 10, 25, 50 mV/V Accuracy ± 0.03 %
Sensor supply 0.5, 1, 2.5, 5 V > 120 Ω,10 V > 350 Ω
Type of bridge full bridge, half bridge, (quarter bridge) min. 120 Ω
Voltage,tachometers
Range 0.5, 1, 2, 5, 10, 20, 50, 100 V max. inputvoltage 100 V
Accuracy ± 0.03 %
Shunt sensors Range 37.5, 75, 150, 300, 600 mV Accuracy ± 0.03 %
Signal currentwith VV module
Range ± 20 mA, 4..20 mAAccuracy ± 0.1 %
PotentiometerRange 6.25, 12.5, 25, 50, 100% Accuracy ± 0.03 % Connection Automatic 3 / 5-wire switch
Thermo-couples J,K,CJC external
Range -100 to +100, +200, +500, +1000(1200) °C
Accuracy ± 0.1 %
Pt100 Range -100 to +100, +200, +500, +1000°C
Accuracy ± 0.1 %
ICP® sensorswith VV module
min. input fre-quency ca. 2 Hz
Accuracy ± 0.1 %Sensor supply 4 mA, 24 V
Frequencyanalog
Range 0.1, 0.2, 0.5, 1, 2, 5, 10, 20 kHz Accuracy ± 0.03 %Input voltage ± 0.05..100 V
Sensor supply 5 V (50 mA), 15 V, ± 15 V (250 mA, not isolated)
Frequencydigital
Range5, 10, 20, 50, 100, 200, 500 Hz, 1, 2, 5, 10, 20, 50, 100, 200, 500kHz
Accuracy ± 0.03 %Input voltage TTL / CMOS
Sensor supply 5 V (50 mA), 15 V, ± 15 V (250 mA, not isolated)
Torquemeter,Telemetry
Range 10 kHz ± 5 kHz,100 kHz ± 45 kHz
Accuracy ± 0.03 %Input voltage TTL / CMOSSensor supply 5 V (50 mA), 15 V (250 mA, n.i.)
Incrementalencoder, halfbridge
Range variable, set by no. of pulsesAccuracy ± 0.03 %Input voltage TTL / CMOS
Sensor supply 5 V (50 mA), 15 V, ± 15 V (250 mA, not isolated)
Directionsense/Sync
without, static, dynamic / with sync, without sync
PWM sensorsRange 100 Hz, 1 kHz, 10 kHz Accuracy ± 0.1 %Input voltage TTL / CMOS
Block Diagram
Dimensions19“ plug-in unit, 3 U height, 5 U width, depth 160 mm
Ordering Code1. 2. 2.a
DASIM-Uni2 - - -1. Model
20 20 kHz sample rate40 40 kHz sample rate
2. Option quarter bridge extension for strain gauge mode1/4
2a. Option bridge resistance120 Quarter bridge extension 120 Ω350 Quarter bridge extension 350 Ω120-350 Quarter bridge extension 120 / 350 Ω switchable
4 pi-F2-messverstaerker_e.odm V1.55-00
GHM GROUP - Standort Imtron | GHM Messtechnik GmbHCarl-Benz-Straße 11 | 88696 Owingen | GERMANYPhone +49 7551 9290-0 | Fax +49 7551 9290-90www.ghm-group.de | [email protected]
Product information Computer Controlled Measurement Amplifiers
5pi-F2-messverstaerker_e V1.55-00
GHM Messtechnik GmbH - Location IMTRONCarl-Benz-Str. 11 D-88696 Owingen Germany Fon +49(0)7551/9290-0 Fax -90www.ghm-messtechnik.de [email protected] Controlled Measurement Amplifiers Test Bench Measurement
DASIM TF2CharacteristicsThe DASIM CF Amplifier offers computer-controlled signalconditioning of strain gauge bridges and inductive sensors.It has 1 DSP per channel. Signal output is with high preci-sion via analog outputs and digitally via Ethernet and CAN.Parameter setting is done with the software DaSoft. Signalfiltering can be configured from 10..1000 Hz.
Technical Data
General
Accuracy see sensorsChannels/unit 2, isolatedSample rate 40 kHzCarrier frequ. 5 kHzBand width 1 kHz
Analog output± 10 V / 12 mA (short proof)2 outputs/channel16 bit resolution
Digital output SPI (internal), CANInput protection ± 15 V, ESD IEC 1000-4-2
Supply voltage+15 V / 70 mA-15 V / 65 mA+5 V / 320 mA
Environmentaltemperature 0..+50 °C
Strain gaugebridges,inductivetorque meters,inductive sen-sors (LVDT)
Range
0.25, 0.5, 1, 2, 4, 5, 10, 25, 50 mV/V for sensor supply 5.0 Veff
0.5, 1, 2, 4, 8, 10, 20, 50, 100 mV/V for sensor supply 2.5 Veff
1.25, 2.5, 5, 10, 20, 25, 50, 100 mV/V for sensor supply 1.0 Veff
2.5, 5, 10, 20, 40, 50, 100, 250, 500 mV/V for sensor supply 0.5 Veff
Accuracy ± 0.1 % Sensor supply 0.5, 1, 2.5, 5 Veff (50 mA)
Type of bridge full bridge, half bridge, (quarter bridge with jumper), min. 120 Ω
Block Diagram
Dimensions19“ plug-in unit, 3 U height, 5 U width, depth 160 mm
Ordering Code
DASIM-TF2
Model5 kHz carrier frequency
pi-F2-messverstaerker_e.odm V1.55-00 5
GHM GROUP - Standort Imtron | GHM Messtechnik GmbHCarl-Benz-Straße 11 | 88696 Owingen | GERMANYPhone +49 7551 9290-0 | Fax +49 7551 9290-90www.ghm-group.de | [email protected]
Product information Computer Controlled Measurement Amplifiers
6 pi-F2-messverstaerker_e V1.55-00
GHM Messtechnik GmbH - Location IMTRONCarl-Benz-Str. 11 D-88696 Owingen Germany Fon +49(0)7551/9290-0 Fax -90www.ghm-messtechnik.de [email protected] Controlled Measurement Amplifiers Test Bench Measurement
SIQUAD Uni4Universal amplifier supported by the Federal Ministry of Economics and Technology based on a resolution by the German Bundestag.
CharacteristicsThe SIQUAD Universal Amplifier offers computer-con-trolled signal conditioning of manifold sensors. It has 1 DSPper channel. Signal output is digital via Ethernet and CANand optional with high precision via analog outputs. Param-eter setting is done with the software DaSoft. Signal filteringcan be configured from 3..3000 Hz at 20 kS/s sample rate.
Technical Data
General
Accuracy see sensorsChannels/unit 4, isolatedAD converter 24 bit / channelSample rate 20 kHzBand width 5 kHz Analog outputoptional
± 10 V / 12 mA (short proof)16 bit resolution
Digital output SPI (internal), CANInput protection ± 100 V, ESD IEC 1000-4-2Supply voltage +5 V / 500 mA
Sensor supply0.5, 1.0, 2.5, 4.5 V (50 mA), 24 V(40 mA) opt. external n.i. up to 40 V (max. 250 mA)
Environmentaltemperature 0..+50 °C
Strain gaugebridges
Range 0.5, 1, 2, 4, 5, 10, 25, 50 mV/V Accuracy ± 0.03 % Sensor supply 0.5, 1, 2.5, 4.5 V (> 120 Ω)Type of bridge4-wire/6-wire
Full / half bridge (> 120 Ω),quarter bridge (120 Ω, 350 Ω)
Voltage
Range 0.1, 0.2, 0.5, 1, 2, 5, 10, 20, 50, 80 V
Accuracy ± 0.05 % max. input volt-age 80 V
Impedance 100 kΩ (> 5 V range)Diff. input yes
Signal current Range ± 20 mA, 4..20 mAAccuracy ± 0.1 %
Currenttransmitter Sensor supply 24 V (max. 40 mA)
Potentiometer3-wire conn.
Range 6.25, 12.5, 25, 50, 100% Accuracy ± 0.1 % Sensor supply 2.5 V
Thermocouples J, K(others opt.)
Range ±100, ±200, -200..+500,-200..+1000 °C
Accuracy ± 0.1 % (without CJC)Adapter cable with integrated CJC (Binder resp.Lemo to TC-Mini) required
Pt100 Range ±100, ±200, -200..+500,-200..+1000 °C
Accuracy ± 0.1 %
ICP® sensors
Range 1, 2, 5, 10 Vmin. input fre-quency appr. 7 Hz
Accuracy ± 0.1 %Sensor supply 4 mA, 22 V
Frequencyanalog
Range 5, 10, 20, 50, 100, 200, 500 Hz,1, 2, 5, 10, 20 kHz
Accuracy ± 0.05 %Input voltage ± 0.02..70 V
Frequencydigital
Range5, 10, 20, 50, 100, 200, 500 Hz, 1, 2, 5, 10, 20, 50, 100, 200, 500kHz
Accuracy ± 0.05 %Input voltage TTL / CMOS (≥ 3.5 V)
Torque meter,Telemetry(Discriminator)
Range Free entry of mid frequency and stroke, max. 100 kHz
Accuracy ± 0.05 %Input voltage TTL / CMOS (≥ 3.5 V)
Incrementalencoder
Range Variable, set by no. of pulsesAccuracy ± 0.05 %Input voltage TTL / CMOSDirectionsense/sync
without, static, dynamic / with sync, without sync
PWM sensorsRange 100 Hz, 1 kHz, 10 kHz Accuracy ± 0.2 %Input voltage TTL / CMOS (≥ 3.5 V)
Block Diagram
Dimensions19“ plug-in unit, 3 U height, 5 U width, depth 160 mm
Ordering Code1. 2. 3.
SIQUAD-Uni4- - -1. Terminal
BB7 7-pole Binder socket (standard)LB7 7-pole Lemo socket
2. Option bridge1/4 BR 1/4-bridge with 2 resistance values (120, 350 Ω)
switchable3. Options output
4 AOBNCR
4 analog outputs wired to back panel with BNC sock-ets
4 AO BNCF
4 analog outputs wired to front panel 10 U with BNC sockets parallel to input sockets
6 pi-F2-messverstaerker_e.odm V1.55-00
GHM GROUP - Standort Imtron | GHM Messtechnik GmbHCarl-Benz-Straße 11 | 88696 Owingen | GERMANYPhone +49 7551 9290-0 | Fax +49 7551 9290-90www.ghm-group.de | [email protected]
Product information Computer Controlled Measurement Amplifiers
7pi-F2-messverstaerker_e V1.55-00
GHM Messtechnik GmbH - Location IMTRONCarl-Benz-Str. 11 D-88696 Owingen Germany Fon +49(0)7551/9290-0 Fax -90www.ghm-messtechnik.de [email protected] Controlled Measurement Amplifiers Test Bench Measurement
SIQUAD DMS4CharacteristicsThe SIQUAD DMS4 (Strain Gauge) Amplifier offers com-puter-controlled signal conditioning of strain gauge bridges.It has 1 DSP per unit. Signal output is digital via Ethernetand CAN and optional with high precision via analog out-puts. Parameter setting is done with the software DaSoft.Signal filtering can be configured from 3..3000 Hz at20 kS/s sample rate.
Technical Data
General
Channels/unit 4, isolatedAD converter 24 bit / channelSample rate 20 kHzBand width 5 kHz Analog outputoptional
± 10 V / 12 mA (short proof)16 bit resolution
Digital output SPI (internal), CANInput protection ± 100 V, ESD IEC 1000-4-2Supply voltage +5 V / 450 mA Environmentaltemperature 0..+50 °C
Strain gaugebridges
Range 0.5, 1, 2, 4, 5, 10, 25, 50 mV/V Accuracy ± 0.03 %Input imped-ance 10 MΩ
Differential input YesSensor supply 0.5, 1, 2.5, 4.1 V (calibrated to 5)
Type of bridge full bridge, half bridge, (quarter bridge optional), min. 120 Ω
Block Diagram (exemplary for 2 channels)
Dimensions19“ plug-in unit, 3 U height, 5 U width, depth 160 mm
Ordering Code1. 2. 3.
SIQUAD-DMS4 - - -
1. TerminalBB7 7-pole Binder socket (standard)BB7G 7-pole Binder socket with Gold contactsLB7 7-pole Lemo socket
2. Option bridge1/4 BR 1/4-bridge with 2 resistance values (120, 350 Ω)
switchable3. Options output
4 AOBNCR
4 analog outputs wired to back panel with BNC sock-ets
4 AO BNCF
4 analog outputs wired to front panel 10 U with BNC sockets parallel to input sockets
pi-F2-messverstaerker_e.odm V1.55-00 7
GHM GROUP - Standort Imtron | GHM Messtechnik GmbHCarl-Benz-Straße 11 | 88696 Owingen | GERMANYPhone +49 7551 9290-0 | Fax +49 7551 9290-90www.ghm-group.de | [email protected]
Product information Computer Controlled Measurement Amplifiers
8 pi-F2-messverstaerker_e V1.55-00
GHM Messtechnik GmbH - Location IMTRONCarl-Benz-Str. 11 D-88696 Owingen Germany Fon +49(0)7551/9290-0 Fax -90www.ghm-messtechnik.de [email protected] Controlled Measurement Amplifiers Test Bench Measurement
SIQUAD DC4SIQUAD DC8CharacteristicsThe SIQUAD DC Amplifier offers computer-controlled sig-nal conditioning of voltage or current signals. It has 1 DSPper unit. Signal output is digital via Ethernet and CAN andoptional with high precision via analog outputs. Parametersetting is done with the software DaSoft. Signal filteringcan be configured from 3..3000 Hz at 20 kS/s sample rate.
Technical Data
General
Channels/unit
4, isolated(8, isolated inputs with common reference ground)
AD converter 24 bit / channel
Sample rate 20 kHz(10 kHz)
Band width 5 kHz(3 kHz)
Analog outputoptional
± 10 V / 12 mA (short proof)16 bit resolution
Digital output SPI (internal), CAN
Input protection ± 100 V ESD IEC 1000-4-2
Supply voltage +5 V / 450 mA Environmentaltemperature 0..+50 °C
Voltage
Range0.01 / 0.02/ 0.05 / 0.1 / 0.2 / 0.25 / 0.3 / 0.5 / 0.6 / 1 / 2 / 5 / 10/ 20 / 50 / 100 V
Accuracy ± 0.03 % / ± 0.1 % (DC8)Input imped-ance
400 kΩ (up to 1V range)160 kΩ (from 2V range)
Differential input Yes
Sensor supply optional via power supply for 4-channel version
Signal currentRange ± 20 mA / 4..20 mAAccuracy ± 0.05 % / ± 0.1 % (DC8)Differential input Yes
Block Diagram (exemplary for 2 channels)
Dimensions19“ plug-in unit, 3 U height, 5 U width, depth 160 mm
… continued next page
8 pi-F2-messverstaerker_e.odm V1.55-00
GHM GROUP - Standort Imtron | GHM Messtechnik GmbHCarl-Benz-Straße 11 | 88696 Owingen | GERMANYPhone +49 7551 9290-0 | Fax +49 7551 9290-90www.ghm-group.de | [email protected]
Product information Computer Controlled Measurement Amplifiers
9pi-F2-messverstaerker_e V1.55-00
GHM Messtechnik GmbH - Location IMTRONCarl-Benz-Str. 11 D-88696 Owingen Germany Fon +49(0)7551/9290-0 Fax -90www.ghm-messtechnik.de [email protected] Controlled Measurement Amplifiers Test Bench MeasurementOrdering Codes
1. 2. 3. 4.
SIQUAD-DC4- - - -1. Terminal
BNC BNC socket (standard)BB5D 5-pole Binder socket (DIN assignment)BB7 7-pole Binder socketLB7 7-pole Lemo socket
2. ModelU VoltageI CurrentU/I Voltage/Current switchable
50 Ω, ±20 mA, 4..20 mAITR for current transmitter incl. 24 V DC supply
3. Option internal sensor supply24V Sensor supply 24 V, max. 40 mA
4. Options output4 AOBNCR
4 analog outputs wired to back panel with BNC sock-ets
4 AO BNCF
4 analog outputs wired to front panel 10 U with BNC sockets parallel to input sockets
1. 2.
SIQUAD-DC8 - -1. Terminal
PHOE 16
8 channels with common isolated inputs on Phoenix Combicon screw terminals
2. Option output8 AOBNCR
8 analog outputs wired to back panel with BNC sock-ets
pi-F2-messverstaerker_e.odm V1.55-00 9
GHM GROUP - Standort Imtron | GHM Messtechnik GmbHCarl-Benz-Straße 11 | 88696 Owingen | GERMANYPhone +49 7551 9290-0 | Fax +49 7551 9290-90www.ghm-group.de | [email protected]
Product information Computer Controlled Measurement Amplifiers
10 pi-F2-messverstaerker_e V1.55-00
GHM Messtechnik GmbH - Location IMTRONCarl-Benz-Str. 11 D-88696 Owingen Germany Fon +49(0)7551/9290-0 Fax -90www.ghm-messtechnik.de [email protected] Controlled Measurement Amplifiers Test Bench Measurement
SIQUAD DC2HVSIQUAD DC2HV-PCharacteristicsThe SIQUAD DC2HV Amplifier offers computer-con-trolled signal conditioning of high voltage or current sig-nals. It has 1 DSP per unit. Signal output is digital viaEthernet and CAN and optional with high precision viaanalog outputs. Parameter setting is done with the soft-ware DaSoft. Signal filtering can be configured from3..3000 Hz at 20 kS/s sample rate.The SIQUAD Power Measurement Amplifier is used tomeasure electrical power. The input data, Voltage andCurrent, are measured with 20 kHz per channel. Withthese results the amplifier computes RMS of voltage andcurrent, frequency, power factor and active and apparent power.For this the amplifier contains a digital signal processor (DSP). Theoutput of the calculated values is available after the first measuredperiod and will be send digitally through Ethernet and CAN.
Technical Data
General
Channels/unit 2, isolatedAD converter 24 bit / channelSample rate 20 kHzBand width 5 kHzAnalog outputoptional
± 10 V / 12 mA (short proof)16 bit resolution
Digital output Ethernet, CAN, SPI (internal)Input protection ± 1 kVSupply voltage +5 V / 450 mA Environmentaltemperature 0..+50 °C
Channel 1 – High voltage input (DC2-HV-P)
High voltage
Range 10 / 20 / 50 / 100 / 200 / 400 / 800 / 1000 V
Accuracy ± 0.1 %Max. input volt-age
1000 V peak
Input imped-ance
1 MΩ
Differential input YesMax. potentialdifference be-tween input andground
500 V peak
Signal input Safety banana plugs
Channel 2 – current input (DC2HV-P)
Signal current
Range 1 A / 5 AAccuracy ± 0.1 %Max. input cur-rent
5 A peak
Shunt 0,1 Ω (unfused)Max. potentialdifference be-tween input andground
250 Vrms
Signal input Safety banana plugs
Channel 2 - Voltage input (DC2HV-P, alternatively)
Voltage
Range 0.1 / 0.2 / 0.5 / 1 / 2 / 5 / 10 / 20 / 50 / 100 V
Accuracy ± 0.03 %Max. input volt-age 100 V peak
Input imped-ance
400 kΩ (up to 1V range)160 kΩ (from 2V range)
Differential input YesMax. potentialdifference be-tween input andground
250 Vrms
Signal input BNC, banana plugs
Channel configuration (DC2HV)
High voltage
Range 10 / 20 / 50 / 100 / 200 / 400 / 800 / 1000 V
Accuracy ± 0.1 %Max. input volt-age 1000 V peak
Input imped-ance 1 MΩ
Differential input Yes
Block Diagram
10 pi-F2-messverstaerker_e.odm V1.55-00
GHM GROUP - Standort Imtron | GHM Messtechnik GmbHCarl-Benz-Straße 11 | 88696 Owingen | GERMANYPhone +49 7551 9290-0 | Fax +49 7551 9290-90www.ghm-group.de | [email protected]
Product information Computer Controlled Measurement Amplifiers
11pi-F2-messverstaerker_e V1.55-00
GHM Messtechnik GmbH - Location IMTRONCarl-Benz-Str. 11 D-88696 Owingen Germany Fon +49(0)7551/9290-0 Fax -90www.ghm-messtechnik.de [email protected] Controlled Measurement Amplifiers Test Bench MeasurementDimensions19“ plug-in unit, 3 U height, 5 U width, depth 160 mm
Ordering Codes1. 2. 3. 4.
SIQUAD-DC2HV-BANHV- - - - P1. Terminal Channel 2
BANHV 2x safety banana plugBAN Banana plugBNC BNC socket for second voltage input (≤ 100 V)
2. Channel configurationUU 1. Channel – Voltages up to 1000 V
2. Channel – Voltages up to 100 V UI 1. Channel – Voltages up to 1000 V
2. Channel – Currents up to 5 A 3. Options output
2 AOBNCR
2 analog outputs wired to back panel with BNC sock-ets
2 AO BNCF
2 analog outputs wired to front panel 10 U with BNC sockets parallel to input sockets
1. 2.
SIQUAD-DC2HV - -1. Terminal
BANHV 2x High Voltage Banana sockets2. Options output
2 AOBNCR
2 analog outputs wired to back panel with BNC sock-ets
2 AO BNCF
2 analog outputs wired to front panel 10 U with BNC sockets parallel to input sockets
Functional PrincipleThe Amplifier acquires both channels with 20 kHz internally and of-fers the following digital output channels:
Channel 1 Dynamic value of channel 1 (high voltage)
Channel 2 True-RMS URMS value of channel 1, calculated using following formula:
URMS=√ 1T ∫t0t 0+T
u ²(t )dt
Channel 3 Power factor λ, calculated using following formula:
λ=PS=cos(φ )
Channel 4 Frequency of channel 1
f= 1T (Resolution: 50 μs)
Channel 5 Dynamic value of channel 2 (current / voltage)
Channel 6 True-RMS IRMS of channel 2, calculated using follow-ing formula:
I RMS=√ 1T ∫t0t0+T
i ²(t)dt
Channel 7 Active power PThe average of p(t)=u(t)i(t) over the period T isnamed as active power P:
P= 1T ∫t0
t 0+T
p (t)dt
Channel 8 Apparent power S, calculated using following for-mula:S=URMS I RMS
All calculations are done in the frequency range of 10 to 200 Hz.All calculated values (channel 2-4, 6-8) will be issued after one pe-riod.
RemarksWith an amplifier you can perform power measurements on single phase power. In order to carry out performance measurements on a three-phase system, you need 3 amplifiers (one per phase). The overall result can then be calculated online in the data acquisition software (eg with DAQSoft). Output of calculated values will start after the first fully acquired pe-riod of the input signal.
pi-F2-messverstaerker_e.odm V1.55-00 11
GHM GROUP - Standort Imtron | GHM Messtechnik GmbHCarl-Benz-Straße 11 | 88696 Owingen | GERMANYPhone +49 7551 9290-0 | Fax +49 7551 9290-90www.ghm-group.de | [email protected]
Product information Computer Controlled Measurement Amplifiers
12 pi-F2-messverstaerker_e V1.55-00
GHM Messtechnik GmbH - Location IMTRONCarl-Benz-Str. 11 D-88696 Owingen Germany Fon +49(0)7551/9290-0 Fax -90www.ghm-messtechnik.de [email protected] Controlled Measurement Amplifiers Test Bench Measurement
SIQUAD Poti4CharacteristicsThe SIQUAD Potentiometer Amplifier offers computer-controlled signal conditioning of potentiometers. It has 1DSP per unit. Signal output is digital via Ethernet and CANand optional with high precision via analog outputs. Param-eter setting is done with the software DaSoft. Signal filter-ing can be configured from 3..3000 Hz at 20 kS/s samplerate.
Technical Data
General
Channels/unit 4, isolatedAD converter 24 bit / channelSample rate 20 kHzBand width 5 kHz Analog outputoptional
± 10 V / 12 mA (short proof)16 bit resolution
Digital output SPI (internal), CANInput protection ± 5 V, ESD IEC 1000-4-2Supply voltage +5 V / 450 mA Environmentaltemperature 0..+50 °C
Potentiometer
Range 6.25, 12,5, 25, 50, 100 % Accuracy ± 0.05 %Input imped-ance 10 MΩ
Differential input YesSensor supply 5 V (50 mA)Connection Automatic 3-/5-wire switch
Block Diagram (exemplary for 2 channels)
Dimensions19“ plug-in unit, 3 U height, 5 U width, depth 160 mm
Ordering Code1. 2.
SIQUAD-Poti4- - -
1. TerminalBB7 7-pole Binder socket (standard)LB7 7-pole Lemo socket
2. Options output4 AOBNCR
4 analog outputs wired to back panel with BNC sock-ets
4 AO BNCF
4 analog outputs wired to front panel 10 U with BNC sockets parallel to input sockets
12 pi-F2-messverstaerker_e.odm V1.55-00
GHM GROUP - Standort Imtron | GHM Messtechnik GmbHCarl-Benz-Straße 11 | 88696 Owingen | GERMANYPhone +49 7551 9290-0 | Fax +49 7551 9290-90www.ghm-group.de | [email protected]
Product information Computer Controlled Measurement Amplifiers
13pi-F2-messverstaerker_e V1.55-00
GHM Messtechnik GmbH - Location IMTRONCarl-Benz-Str. 11 D-88696 Owingen Germany Fon +49(0)7551/9290-0 Fax -90www.ghm-messtechnik.de [email protected] Controlled Measurement Amplifiers Test Bench Measurement
SIQUAD TC, TC8CharacteristicsThe SIQUAD Thermocouple Amplifier offers computer-controlled signal conditioning of thermocouples. It has 1DSP per unit. Signal output is digital via Ethernet andCAN and optional with high precision via analog outputs.Parameter setting is done with the software DaSoft. Sig-nal filtering can be configured from 3..3000 Hz at 10 kS/ssample rate.
Technical Data
Channels / unit 4, isolated(8, isolated inputs with common ground)
AD converter 24 bit / channel
Sample rate 10 kHz(500 Hz for 8 channels)
Band width 3 kHz(150 Hz)
Analog outputoptional
± 10 V / 12 mA (short proof)16 bit resolution
Digital output SPI (internal), CANInput protection ± 5 V, ESD IEC 1000-4-2Supply voltage +5 V / 450 mA Env.temperature 0..+50 °CRange -100 to +100, +200, +500, +1000 (1200) °CAccuracy ± 0.2 % incl. CJCTC types J, K, others on requestDifferential input YesTerminal Mini thermo sockets as per TC type
Block Diagram (exemplary for 2 channels)
Dimensions19“ plug-in unit, 3 U height, 5 U width, depth 160 mm
Ordering Codes1. 2. 3.
SIQUAD-TC4- -
1. ModelJ Thermocouples type JK Thermocouples type KN Thermocouples type NT Thermocouples type T
2. Options range1200 Range 1200 °C (only type K)
3. Options output4 AOBNCR
4 analog outputs wired to back panel with BNC sock-ets
4 AO BNCF
4 analog outputs wired to front panel 10 U with BNC sockets parallel to input sockets
1. 2. 3. .
SIQUAD-TC8- -
1. ModelJ Thermocouples type JK Thermocouples type KN Thermocouples type NT Thermocouples type T
2. Options range1200 Range 1200 °C (only type K)
3. Options output8 AOBNCR
8 analog outputs wired to back panel with BNC sock-ets
pi-F2-messverstaerker_e.odm V1.55-00 13
GHM GROUP - Standort Imtron | GHM Messtechnik GmbHCarl-Benz-Straße 11 | 88696 Owingen | GERMANYPhone +49 7551 9290-0 | Fax +49 7551 9290-90www.ghm-group.de | [email protected]
Product information Computer Controlled Measurement Amplifiers
14 pi-F2-messverstaerker_e V1.55-00
GHM Messtechnik GmbH - Location IMTRONCarl-Benz-Str. 11 D-88696 Owingen Germany Fon +49(0)7551/9290-0 Fax -90www.ghm-messtechnik.de [email protected] Controlled Measurement Amplifiers Test Bench Measurement
SIQUAD Pt100 4CharacteristicsThe SIQUAD Pt100 Amplifier offers computer-controlledsignal conditioning of RTD sensors. It has 1 DSP per unit.Signal output is digital via Ethernet and CAN and optionalwith high precision via analog outputs. Parameter setting isdone with the software DaSoft. Signal filtering can be con-figured from 3..3000 Hz at 10 kS/s sample rate.
Technical DataChannels/unit 4, isolatedAD converter 24 bit / channelSample rate 10 kHzBand width 3 kHz Analog outputoptional
± 10 V / 12 mA (short proof)16 bit resolution
Digital output SPI (internal), CANInput protection ± 5 V, ESD IEC 1000-4-2Supply voltage +5 V / 450 mA Environmental temperature 0..+50 °CRange -100 to +100, +200, +500, +1000 °CAccuracy ± 0.05 %Input impedance 10 MΩDifferential input YesSensor supply 1 mA
Block Diagram (exemplary for 2 channels)
Dimensions19“ plug-in unit, 3 U height, 5 U width, depth 160 mm
Ordering Code1. 2.
SIQUAD-Pt100 4- -
1. TerminalBB5 5-pole Binder socket (standard)
2. Options output4 AOBNCR
4 analog outputs wired to back panel with BNC sock-ets
4 AO BNCF
4 analog outputs wired to front panel 10 U with BNC sockets parallel to input sockets
14 pi-F2-messverstaerker_e.odm V1.55-00
GHM GROUP - Standort Imtron | GHM Messtechnik GmbHCarl-Benz-Straße 11 | 88696 Owingen | GERMANYPhone +49 7551 9290-0 | Fax +49 7551 9290-90www.ghm-group.de | [email protected]
Product information Computer Controlled Measurement Amplifiers
15pi-F2-messverstaerker_e V1.55-00
GHM Messtechnik GmbH - Location IMTRONCarl-Benz-Str. 11 D-88696 Owingen Germany Fon +49(0)7551/9290-0 Fax -90www.ghm-messtechnik.de [email protected] Controlled Measurement Amplifiers Test Bench Measurement
SIQUAD ICP4CharacteristicsThe SIQUAD ICP4 Amplifier offers computer-controlledsignal conditioning of piezo-electric sensors. It has 1 DSPper unit. Signal output is digital via Ethernet and CAN andoptional with high precision via analog outputs. Parametersetting is done with the software DaSoft. Signal filteringcan be configured from 3..3000 Hz at 20 kS/s samplerate.
Technical DataChannels/unit 4, isolatedAD converter 24 bit / channelSample rate 20 kHzBand width 5 kHz Analog outputoptional
± 10 V / 12 mA (short proof)16 bit resolution
Digital output SPI (internal), CANInput protection ± 100 V, ESD IEC 1000-4-2Supply voltage +5 V / 450 mA Environmental temperature 0..+50 °CRange 1, 2, 5, 10 VAccuracy ± 0.05 %Input impedance 1 MΩDifferential input YesSensor supply 4 mA (at 24 V)
Block Diagram (exemplary for 2 channels)
Dimensions19“ plug-in unit, 3 U height, 5 U width, depth 160 mm
Ordering Code1. 2.
SIQUAD-ICP4- -
1. TerminalBNC BNC socket (standard)LB7 7-pole Lemo socket
2. Options output4 AOBNCR
4 analog outputs wired to back panel with BNC sock-ets
4 AO BNCF
4 analog outputs wired to front panel 10 U with BNC sockets parallel to input sockets
pi-F2-messverstaerker_e.odm V1.55-00 15
GHM GROUP - Standort Imtron | GHM Messtechnik GmbHCarl-Benz-Straße 11 | 88696 Owingen | GERMANYPhone +49 7551 9290-0 | Fax +49 7551 9290-90www.ghm-group.de | [email protected]
Product information Computer Controlled Measurement Amplifiers
16 pi-F2-messverstaerker_e V1.55-00
GHM Messtechnik GmbH - Location IMTRONCarl-Benz-Str. 11 D-88696 Owingen Germany Fon +49(0)7551/9290-0 Fax -90www.ghm-messtechnik.de [email protected] Controlled Measurement Amplifiers Test Bench Measurement
SIQUAD FU2CharacteristicsThe SIQUAD Frequency Amplifier offers computer-con-trolled signal conditioning of arbitrary periodic frequencysignals. Each of the 2 channels has 2 differential trackswith AC coupling and a following 4-step amplifier stage.So signals with amplitudes from 500 mVpp to 100 Vpp canbe handled. Each channel has an additional digital input.An isolated sensor supply is integrated. There is 1 DSPper unit. Signal output is digital via Ethernet and CAN and optionalwith high precision via analog outputs. Parameter setting is donewith the software DaSoft.
Technical Data
General
Channels/unit
2 with 2 differential tracks each and 1 digital input, isolated
Sample rate 20 kHzAnalog outputoptional
± 10 V / 12 mA (short proof)16 bit resolution
Digital output SPI (internal), CANInput protection ± 100 V, ESD IEC 1000-4-2Input imped-ance 200 kΩ
min. input frequency appr.1 Hz
Input sensitivity 0.5, 1.0, 2.5, ≥5.0 Vpp
Supply voltage +5 V / 450 mA Environmentaltemperature 0..+50 °C
Sensor supply
unregulated (± 15 %) 2 W (Socket)1 value: 3.3, 5, 9, 12, 15, 24 V
regulated (± 5 %) 3 W (soldered)1 value: 3.3, 5, 12, 15 V
FU converterRange
5, 10, 20, 50, 100, 200, 500 Hz, 1, 2, 5, 10, 20, 50, 100, 200, 500,1000 kHz
resolution min. 12 bitmax. dynamics 10 kHz
Incrementalencoder
Range 100..106 pulsesresolution 16 bitmax. counterfrequency 1 MHz
Block Diagram
Dimensions19“ plug-in unit, 3 U height, 5 U width, depth 160 mm
Ordering Code1. 2.
SIQUAD-FU2- -
1. TerminalBB7 7-pole Binder socket (standard)
2. Sensor supplyXG 3.3, 5, 12, 15 V ± 5 %, regulatedXU 3.3, 5, 9, 121, 15, 24 V, ± 15 %, unregulated, socket
1 Standard value, without option 12V unregulated will be shipped
16 pi-F2-messverstaerker_e.odm V1.55-00
GHM GROUP - Standort Imtron | GHM Messtechnik GmbHCarl-Benz-Straße 11 | 88696 Owingen | GERMANYPhone +49 7551 9290-0 | Fax +49 7551 9290-90www.ghm-group.de | [email protected]
Product information Computer Controlled Measurement Amplifiers
17pi-F2-messverstaerker_e V1.55-00
GHM Messtechnik GmbH - Location IMTRONCarl-Benz-Str. 11 D-88696 Owingen Germany Fon +49(0)7551/9290-0 Fax -90www.ghm-messtechnik.de [email protected] Controlled Measurement Amplifiers Test Bench Measurement
SIQUAD DIO-8CharacteristicsThe SIQUAD DIO-8 Plug-in Unit offers computer-con-trolled signal conditioning of up to 8 digital input signalsand drives 8 relay outputs. The inputs are insulated by op-tocouplers. The relay outputs can be configured per chan-nel by jumpers to make or break. Front panel LEDs indi-cates switching states of inputs and outputs.
With the 4Z unit inputs can be also configured with parameter set-ting software DaSoft as simple frequency inputs for conditioning ofdigital frequency signals. A maximum of 4 frequency inputs is possi-ble. They can be set as FV converter or incremental encoder. Sig-nal output (FV, Z mode) is digital via Ethernet and CAN. Parametersetting is done with the software DaSoft.
Technical Data
General
Channels/unit
8 digital inputs, isolated8 relay contacts at output
sample rate 20 kHzDigital output SPI (internal), CANInput protection ± 100 V, ESD IEC 1000-4-2Input imped-ance 200 kΩ
min. inputfrequency ca.1 Hz
Input sensitivity 0.5, 1.0, 2.5, ≥5.0 Vpp
Supply voltage +5 V / 450 mA Environmentaltemperature 0..+50 °C
Connection 2x 16-pole screw terminals
Inputs as8 DI(opto decou-pled)
High-level + 3.5..60 VLow-level - 30..+1 V
Input current appr. 6 mA (0..30 V)6..36 mA (-30..+60 V)
max. input frequency 20 kHz
Inputs as FVconvertermax. 4
Range5, 10, 20, 50, 100, 200, 500 Hz, 1, 2, 5, 10, 20, 50, 100, 200, 500,1000 kHz
resolution min. 12 bitmax. dynamics 10 kHz
Inputs as In-cremental counter,max. 4
Range 100..106 pulsesresolution 16 bitmax. counterfrequency 1 MHz
Outputs as relay contacts
Switch currents max. 2 A or 10 ASwitch voltage max. 220 V DCSwitch power max. 60 WContact resist. 50 mΩmax. output frequency appr.. 15 Hz
Switching cy-cles
mechanical min.108
electrical min. 105
Dimensions19“ plug-in unit, 3 U height, 5 U (10 U) width, depth 160 mm
Ordering Code1.
SIQUAD-DIO8-
1. Model extension4Z count function for 4 counters
SIQUAD AO4CharacteristicsThe SIQUAD AO4 Plug-in Unit provides up to 4 analogoutputs. The signal level can be set by the parameter set-ting software or via a LabVIEW application.
Technical Data
General
Channels/unit
4 analog outputs,isolated to system
DA converter 4 x 16 bitDigital output SPI (internal), CANSupply voltage +5 V / 450 mA Environmentaltemperature 0..+50 °C
OutputsVoltage output ± 10 Vmax. load ± 10 mACurrent output ± 20 mA (option)
Dimensions19“ plug-in unit, 3 U height, 5 U width, depth 160 mm
Ordering Code1. 2.
SIQUAD-AO4- -
1. OutputU Voltage ± 10 V to BNC socketU/I Voltage or current to BNCUI Voltage and current to BB7
2. TerminalBNC BNC socketBB7 7-pole Binder socket (only UI)
pi-F2-messverstaerker_e.odm V1.55-00 17
GHM GROUP - Standort Imtron | GHM Messtechnik GmbHCarl-Benz-Straße 11 | 88696 Owingen | GERMANYPhone +49 7551 9290-0 | Fax +49 7551 9290-90www.ghm-group.de | [email protected]
Product information Computer Controlled Measurement Amplifiers
18 pi-F2-messverstaerker_e V1.55-00
GHM Messtechnik GmbH - Location IMTRONCarl-Benz-Str. 11 D-88696 Owingen Germany Fon +49(0)7551/9290-0 Fax -90www.ghm-messtechnik.de [email protected] Controlled Measurement Amplifiers Test Bench Measurement
CAN InterfaceCharacteristicsThe CAN Interface Unit offers synchronous acquisi-tion of CAN messages from a CAN bus. These dataare put on the internal high-speed bus and are pro-cessed simultaneously with the other measurementdata by the central unit. They can be handled furtherwith an appropriate data acquisition software likeDAQSoft or DASYLab (by using the DASYLab driver).Parameter setting is done with the software DaSoft.
The CAN-Interface can be used with both DASIM andSIQUAD systems.
Technical DataCAN nodes 2, independent
Signals/node 24 at 16 bit (Dual Mode)48 at 16 bit (Single Mode)
Signals/message 8
Data formats
Boolean (8 bit)Signed Char (8 bit)Unsigned Char (8 bit)Signed Integer (16 bit)Unsigned Integer (16 bit)Signed Long (32 bit)Unsigned Long (32 bit)Float (32 bit)Double (64 bit)
Transmission rates:CAN Low-Speed
CAN High-Speed
5 (only node A), 10, 20, 40, 50, 80, 100 kBaud
5 (only node A), 10, 20, 40, 50, 80, 100, 125, 250, 400, 500, 666, 800, 1000 kBaud
Sample rate 20 kHzDigital output SPI (internal)Supply voltage. +5 V / 310 mA Environmentaltemperature 0..+50 °C
Block Diagram
Dimensions19“ plug-in unit, 3 U height, 5 U width, depth 160 mm
Ordering Codes
DASIM-CAN-IF2
respectively
SIQUAD-CAN-IF2
ModelCAN Interface, 2 CAN nodes
18 pi-F2-messverstaerker_e.odm V1.55-00
GHM GROUP - Standort Imtron | GHM Messtechnik GmbHCarl-Benz-Straße 11 | 88696 Owingen | GERMANYPhone +49 7551 9290-0 | Fax +49 7551 9290-90www.ghm-group.de | [email protected]
Product information Computer Controlled Measurement Amplifiers
19pi-F2-messverstaerker_e V1.55-00
GHM Messtechnik GmbH - Location IMTRONCarl-Benz-Str. 11 D-88696 Owingen Germany Fon +49(0)7551/9290-0 Fax -90www.ghm-messtechnik.de [email protected] Controlled Measurement Amplifiers Test Bench Measurement
Central UnitCharacteristicsThe Central Unit is the interface between the internalhigh-speed bus, the Ethernet connection, an RS 232 inter-face, and the internal RS 485 bus. It is a plug-in unit forthe housing and provides the clock for the amplifiers aswell as external clocking and synchronization for additionalhousings resp. chassis. External trigger signals are alsoadministered by the central unit. A remote control can beconnected via the remote interface. Parameter setting of the ampli-fiers is done with the software DaSoft via the Ethernet or RS 232interface of the central unit.
Technical DataSample rate 40 kHzDigital output RS 232, EthernetSupply voltage. +5 V / 270 mA Environmentaltemperature 0..+50 °C
Block Diagram
Dimensions19“ plug-in unit, 3 U height, 5 U width, depth 160 mm
Ordering CodeDASIM-G-ZE-DE (to be ordered separately for DASIM, included inchassis for SIQUAD)
Parameter SettingSoftwareCharacteristicsThe Parameter Setting Software DaSoft allows configuration of asystem and its communication interfaces for individual setting up ofthe amplifiers and add-on units.
Sensor data can be stored in a sensor database for automatic sys-tem configuration. Integration into a customer-specific parametersetting software is possible via a communication DLL.The following settings are done with DaSoft:
• Type of sensor, measurement ranges, sensor excitation andfurther options for the functionality of the amplifiers.
• Sample rate 1 Hz to 40 kHz (depending on amplifier type),sensor range (nominal value), and physical unit.
DaSoft provides the system settings and generates an interface file“DDL.int“ with the necessary specifications for data acquisition. Thedata acquisition software (DAQSoft or others with correspondingdrivers) takes this information of the “DDL.int“. The file is alwaysupdated with actual data after each communication of DaSoft withthe measurement system. If changes were done in the system withDaSoft, it will be automatically recognized by the acquisition soft-ware. Therefore it is not possible to measure with wrong parame-ters.
Ordering CodeNo separate ordering code, as included in price of central unit andprice of USB-to-CAN configuration package.
pi-F2-messverstaerker_e.odm V1.55-00 19
GHM GROUP - Standort Imtron | GHM Messtechnik GmbHCarl-Benz-Straße 11 | 88696 Owingen | GERMANYPhone +49 7551 9290-0 | Fax +49 7551 9290-90www.ghm-group.de | [email protected]
Product information Computer Controlled Measurement Amplifiers
20 pi-F2-messverstaerker_e V1.55-00
GHM Messtechnik GmbH - Location IMTRONCarl-Benz-Str. 11 D-88696 Owingen Germany Fon +49(0)7551/9290-0 Fax -90www.ghm-messtechnik.de [email protected] Controlled Measurement Amplifiers Test Bench Measurement
Data AcquisitionSoftwareCharacteristicsThe Measurement Software DAQSoft offers acquisition and visu-alization of data for DASIM and SIQUAD systems. First parametersof the amplifiers are set with DaSoft. DaSoft provides the systemsettings and generates an interface file “DDL.int“ with the neces-sary specifications for data acquisition. DAQSoft takes this informa-tion of the “DDL.int“ automatically. The file is always updated withactual data after each communication of DaSoft with the measure-ment system. If changes were done in the system with DaSoft, itwill be automatically recognized by DAQSoft and notified. Thereforeit is not possible to measure with wrong parameters.
DAQSoft offers essentially the following features:
Measurement: Measurement over time, X/Y measurement Measurement with several systems and different IP ad-
dresses Signal acquisition of various data formats from a CAN In-
terface Different settings for triggers, combined with level moni-
toring Recurring measurement (serial measurement) Setting of automatic saving intervals Measurement with on-line view and pre-monitoring Acquisition of Video data from a DigiCam synchronous
with measurement data Acquisition of GPS data and route tracing synchronous
with measurement data
Visualization and processing: Visualization of data in a graph (main, side, stacked
graphs) Visualization as instantaneous value (analog, numerical)
and in tabular form Visualization of video data as single pictures Import of video data in AVI format Real time information Analysis of saved measurements with zoom and cursor
modes Comparison of measurements Combination of measurements Mathematical post-processing of selected measurement
channels Post-filtering of selected measurement channels Analysis with FFT and power spectrum
Exports, reports, miscellaneous: Export function into other data formats like Famos, DIA-
dem, ASCII, MATLAB Export of video data in AVI format or as single picture Generating different reports as HTML or Crystal report
with different layouts Event logging with log file Project based directory structure
Drivers for other Windows-based data acquisition software likeDASYLab and LabVIEW are optionally available.
An extensive functional library “DataEngine.dll“ is available for inte-grating the systems into an own data acquisition software or envi-ronment. It transmits triggers and measurement data, and receivesthe other way parameters for the central unit like sample rates, trig-ger conditions and information about the selected channels
DaSoft and DAQSoft are running under Windows 2000, Windows XP, Windows 7 (32 and 64 bit). DAQSoft also needs a .NET envi-ronment. For acquisition with high sample rate and therefore largeamount of data, a computer starting with Dual-Core processor (orcomparable) and 2.5 GHz, 4 GB RAM, and fast hard disk is recom-mended.
Ordering CodesData acquisition softwareDASIM-SW-DAQSOFTSIQUAD-SW-DAQSOFT
DriversDASIM-SW-TR-DAS for DASYLabDASIM-SW-TR-LAB for LabVIEW
SIQUAD-SW-TR-DAS for DASYLabSIQUAD-SW-TR-LAB for LabVIEW
20 pi-F2-messverstaerker_e.odm V1.55-00
GHM GROUP - Standort Imtron | GHM Messtechnik GmbHCarl-Benz-Straße 11 | 88696 Owingen | GERMANYPhone +49 7551 9290-0 | Fax +49 7551 9290-90www.ghm-group.de | [email protected]
Product information Computer Controlled Measurement Amplifiers
21pi-F2-messverstaerker_e V1.55-00
GHM Messtechnik GmbH - Location IMTRONCarl-Benz-Str. 11 D-88696 Owingen Germany Fon +49(0)7551/9290-0 Fax -90www.ghm-messtechnik.de [email protected] Controlled Measurement Amplifiers Test Bench Measurement
HousingsCharacteristicsThe DASIM and SIQUAD Amplifiers fit into (standard) 19” chassisand desktop housings. The housings can be tailored to customer-specific needs concerning number of units and power supply. Formobile applications a wide-range power supply is available.
Technical Data
Supply voltage 110..230 V AC9..36 V DC
Power supply Switching mode(optional linear)
Input DASIMInput SIQUADOutput DASIMOutput SIQUAD (optional)
via back panel with Lemo socketssensor specific on front panel
via back panel with BNC socketsFront / or back panel with BNC-
socket or screw terminalsEnvironmental temperature 0..50 °CDimensionsDesktop housingChassisMini System
28..84 U84 U21 U
Dimensions19“ Housings
Width 21, 28, 63, 84 U resp. chassis 84 UHeight 3 U (optional 4 U)depth housing 316 mm (256..496 mm)depth chassis 340 mm (240..460 mm)
Ordering Codes1. 2. 3. 4.
DASIM-G - - - -1. Basic housing without digital interface
VR 19“ chassisVT 19“ desktop housing 28..84 TE
2. Extension Ethernet interfaceETH
3. Number of bays 4 for 4 plug-in units 8 for 8 plug-in units16 for 16 plug-in units
4. Power supplyB DC 9..36 VN AC 110..230V, 50 Hz
Central unit DASIM-G-ZE-DW has to be ordered separately
1. 2. 3. 4.
SIQUAD-GD - - -1. Housing type
VR 19“ chassisVT 19“ desktop housing 28..84 TE
2. Number of slots 4 for 4 plug-in units 8 for 8 plug-in units16 for 16 plug-in units
3. Power supplyB DC 9..36 VN AC 110..230V, 50 Hz
4. Options Sensor supply12V5A Sensor supply SIQUAD-DC with extra power supply
12 V 5 A24V1A Sensor supply SIQUAD-DC with extra power supply
24 V 1 A24V5A Sensor supply SIQUAD-DC with extra power supply
24 V 5 ACentral unit is included in price of housing
pi-F2-messverstaerker_e.odm V1.55-00 21
GHM GROUP - Standort Imtron | GHM Messtechnik GmbHCarl-Benz-Straße 11 | 88696 Owingen | GERMANYPhone +49 7551 9290-0 | Fax +49 7551 9290-90www.ghm-group.de | [email protected]
Product information Computer Controlled Measurement Amplifiers
22 pi-F2-messverstaerker_e V1.55-00
GHM Messtechnik GmbH - Location IMTRONCarl-Benz-Str. 11 D-88696 Owingen Germany Fon +49(0)7551/9290-0 Fax -90www.ghm-messtechnik.de [email protected] Controlled Measurement Amplifiers Test Bench Measurement
CAN Compact Module Uni4Universal amplifier supported by the Federal Ministry of Economics and Technology based on a resolution by the German Bundestag.
CharacteristicsThe SIQUAD CAN Compact Module Uni4 offerscomputer-controlled signal conditioning of varioussensors in 1 module. It has 1 DSP per channel.Signal output is digital via CAN. The protocol isCAN 2.0B. Parameter setting is done with thesoftware DaSoft via a USB-to-CAN interface. Sig-nal filtering can be configured from 3..3000 Hz at20 kS/s sample rate.
Technical Data
General
Accuracy see sensorsChannels/unit 4, 2x4, isolatedAD converter 24 bit / channelSample rate max. 20 kHzBand width max. 5 kHz Digital output CANInput protection ± 100 V, ESD IEC 1000-4-2Supply voltage 9..36 V DC
Sensor supply 0.5, 1.0, 2.5, 4.5 V (50 mA), 24 V(40 mA)
Environmentaltemperature 0..+50 °C
Strain gaugebridges
Range 0.5, 1, 2, 4, 5, 10, 25, 50 mV/V Accuracy ± 0.03 % Sensor supply 0.5, 1, 2.5, 4.5 V (> 120 Ω)Type of bridge4-wire/6-wire
Full/half bridge (> 120 Ω),quarter bridge (120 Ω, 350 Ω)
Voltage
Range 0.1, 0.2, 0.5, 1, 2, 5, 10, 20, 50, 80 V
Accuracy ± 0.05 % max. input volt-age 80 V
Impedance 100 kΩ (> 5 V range)Diff. input yes
Signal current Range ± 20 mA, 4..20 mAAccuracy ± 0.1 %
Currenttransmitter Sensor supply 24 V (max. 40 mA)
Potentiometer3-wire conn.
Range 6.25, 12.5, 25, 50, 100% Accuracy ± 0.1 % Sensor supply 2.5 V
Thermocouples J,K(others optional)
Range ±100, ±200, -200..+500,-200..+1000 °C
Accuracy ± 0.1 % (without CJC)Adapter cable with integrated CJC mandatory
Pt100 Range ±100, ±200, -200..+500,-200..+1000 °C
Accuracy ± 0.1 %
ICP® sensors
Range 1, 2, 5, 10 Vmin. input fre-quency appr. 7 Hz
Accuracy ± 0.1 %Sensor supply 4 mA, 22 V
Frequencyanalog
Range 5, 10, 20, 50, 100, 200, 500 Hz,1, 2, 5, 10, 20 kHz
Accuracy ± 0.05 %Input voltage ± 0.02.70 V
Frequencydigital
Range5, 10, 20, 50, 100, 200, 500 Hz, 1, 2, 5, 10, 20, 50, 100, 200, 500kHz
Accuracy ± 0.05 %Input voltage TTL / CMOS (≥ 3.5 V)
Torque meter,Telemetry(Discriminator)
Range Free entry of mid frequency and stroke, max. 100 kHz
Accuracy ± 0.05 %Input voltage TTL / CMOS (≥ 3.5 V)
Incrementalencoder
Range Variable, set by no. of pulsesAccuracy ± 0.05 %Input voltage TTL / CMOSDirectionsense/sync
without, static, dynamic / with sync, without sync
PWM sensorsRange 100 Hz, 1 kHz, 10 kHz Accuracy ± 0.2 %Input voltage TTL / CMOS (≥ 3.5 V)
Block Diagram
DimensionsSCC1: 130 x 250 x 45 mm, 130 x 130 x 45 mm (WxHxD)
Ordering Code
1. 2. 3.
SCC1 - - -
1. Sensor type with 1 amplifier unitUNI4 4 channels Universal
2. TerminalBB7 7-pole Binder socketLB7 7-pole Lemo socket
3. Housing typeBox (standard)
L FlangeT Mounting rail
22 pi-F2-messverstaerker_e.odm V1.55-00
GHM GROUP - Standort Imtron | GHM Messtechnik GmbHCarl-Benz-Straße 11 | 88696 Owingen | GERMANYPhone +49 7551 9290-0 | Fax +49 7551 9290-90www.ghm-group.de | [email protected]
Product information Computer Controlled Measurement Amplifiers
23pi-F2-messverstaerker_e V1.55-00
GHM Messtechnik GmbH - Location IMTRONCarl-Benz-Str. 11 D-88696 Owingen Germany Fon +49(0)7551/9290-0 Fax -90www.ghm-messtechnik.de [email protected] Controlled Measurement Amplifiers Test Bench Measurement
CAN Compact ModulesCharacteristicsThe SIQUAD CAN Compact Modules offercomputer-controlled signal conditioning ofvarious sensors. There are sensor-specificamplifiers available with 1 DSP per amplifierunit. Signal output is digital via CAN. The pro-tocol is CAN 2.0B. Parameter setting is donewith the software DaSoft via a USB-to-CANinterface. Signal filtering can be configuredfrom 3..3000 Hz at 20 kS/s sample rate.
Technical Data
General
Accuracy see sensors
Channels/unit
4, 2x4, isolated(8, 2x8, isolated inputs with com-mon ground)
AD converter 24 bit / channelSample rate max. 20 kHzBand width max. 5 kHz Digital output CANInput protection ± 100 V, ESD IEC 1000-4-2Supply voltage 9..36 V DCEnvironmentaltemperature 0..+50 °C
Strain gaugebridges
Range 0.5, 1, 2, 4, 5, 10, 25, 50 mV/V Accuracy ± 0.03 % Sensor supply 0.5, 1, 2.5, 4.5 V (> 120 Ω)Type of bridge full bridge, half bridge, (> 120 Ω)
Voltage
Range 0.1, 0.2, 0.5, 1, 2, 5, 10, 20, 50, 80 V
max. input volt-age 80 V
Accuracy ± 0.03 %
Signal current Range ± 20 mA, 4..20 mAAccuracy ± 0.1 %
Thermo-couples J,K
Range -100 to +100, +200, +500, +1000(1200) °C
Accuracy ± 0.1 % (without CJC)
Pt100 Range -100 to +100, +200, +500, +1000°C
Accuracy ± 0.1 %
ICP® Sensors
Range 1, 2, 5, 10 Vmin. inputfrequency appr.. 2 Hz
Accuracy ± 0.1 %Sensor supply 4 mA, 24 V
Frequencyanalog
Range 0.1, 0.2, 0.5, 1, 2, 5, 10, 20, 50, 100 kHz
Accuracy ± 0.03 %Input voltage ± 0.05..80 VSensor supply 4.5 V (50 mA)
Frequencydigital
Range5, 10, 20, 50, 100, 200, 500 Hz, 1, 2, 5, 10, 20, 50, 100, 200, 500kHz
Accuracy ± 0.03 %Input voltage TTL / CMOSSensor supply 4.5 V (50 mA)
Torque meter,Telemetry
Range 10 kHz ± 5 kHz,100 kHz ± 45 kHz
Accuracy ± 0.03 %Input voltage TTL / CMOSSensor supply 4.5 V (50 mA)
Incrementalencoder
Range Variable, set by no. of pulsesAccuracy ± 0.03 %Input voltage TTL / CMOSSensor supply 4.5 V (50 mA)Directionsense/Sync
without, static, dynamic / with sync, without sync
Block Diagram (exemplary for 2 channels)
DimensionsSCC1: 130 x 250 x 45 mm, 130 x 130 x 45 mm (WxHxD)SCC2: 130 x 250 x 75 mm, 130 x 130 x 75 mm (WxHxD)
Ordering Codes see next page
pi-F2-messverstaerker_e.odm V1.55-00 23
GHM GROUP - Standort Imtron | GHM Messtechnik GmbHCarl-Benz-Straße 11 | 88696 Owingen | GERMANYPhone +49 7551 9290-0 | Fax +49 7551 9290-90www.ghm-group.de | [email protected]
Product information Computer Controlled Measurement Amplifiers
24 pi-F2-messverstaerker_e V1.55-00
GHM Messtechnik GmbH - Location IMTRONCarl-Benz-Str. 11 D-88696 Owingen Germany Fon +49(0)7551/9290-0 Fax -90www.ghm-messtechnik.de [email protected] Controlled Measurement Amplifiers Test Bench MeasurementOrdering Codes
1. 2. 3.
SCC1 - - -
1. Sensor type with 1 amplifier unitDMS4 4 channels Strain Gauge DCU4 4 channels DC voltage DCI4 4 channels Signal current DCU8 8 channels DC voltageTC4J 4 channels Thermocouples type JTC4K 4 channels Thermocouples type KTC8K 8 channels Thermocouples type KTC4T 4 channels Thermocouples type TPT100 4 4 channels Pt100 ICP4 4 channels ICPAO4 4 channels voltage ± 10 V to BNC socketsAO8 1x8 channels voltage ± 10 V to BNC socketsDIO8 simple DIO operationDIO8-4Z count function for 4 counters
2. TerminalStandard BNC, MTC, BB5
BB7 7-pole Binder socketLB7 7-pole Lemo socket
3. Housing typeH Box (standard)L FlangeT Mounting rail
1. 2.
SCC2 - -
1. Sensor type with 2 amplifier unitsTC4J 2x4 channels Thermocouples type JTC4K 2x4 channels Thermocouples type KTC8K 2x8 channels Thermocouples type KTC4T 2x4 channels Thermocouples type T
2. Housing typeH Box (standard)L FlangeT Mounting rail
1. 2.
SCC-KONF - -
1. InterfaceX USB-CAN Adapter for all CAN Modules with IXXAT
driverV Vector driver
2. ModelDW Windows software for parameterizing of modules
24 pi-F2-messverstaerker_e.odm V1.55-00
GHM GROUP - Standort Imtron | GHM Messtechnik GmbHCarl-Benz-Straße 11 | 88696 Owingen | GERMANYPhone +49 7551 9290-0 | Fax +49 7551 9290-90www.ghm-group.de | [email protected]
Product information Computer Controlled Measurement Amplifiers
25pi-F2-messverstaerker_e V1.55-00
GHM Messtechnik GmbH - Location IMTRONCarl-Benz-Str. 11 D-88696 Owingen Germany Fon +49(0)7551/9290-0 Fax -90www.ghm-messtechnik.de [email protected] Controlled Measurement Amplifiers Test Bench Measurement
CAN Mounting-Rail Module UNIUniversal amplifier supported by the Federal Ministry of Economics and Technology based on a resolution by the German Bundestag.
CharacteristicsThe SIQUAD CAN mounting-rail module Uni offerscomputer-controlled universal signal conditioning of var-ious sensors. There is a 1- or 2-channel version avail-able. It has 1 DSP per channel. Signal output is digitalvia CAN. Protocol is CAN 2.0B. Parameter setting isdone with the software DaSoft via a USB-to-CAN inter-face. Signal filtering can be configured from 3..3000 Hzat 20 kS/s sample rate.
Technical Data
General
Accuracy see sensorsChannels/unit 2, isolatedAD converter 24 bit / channelSample rate max. 20 kHzBand width max. 5 kHz Digital output CANInput protection ± 100 V, ESD IEC 1000-4-2Supply voltage 9..36 V DC
Sensor supply0.5, 1.0, 2.5, 4.5 V (50 mA), 24 V(40 mA) opt. external n.i. up to 40 V (max. 250 mA)
Environmentaltemperature 0..+50 °C
Strain gaugebridges
Range 0.5, 1, 2, 4, 5, 10, 25, 50 mV/V Accuracy ± 0.03 % Sensor supply 0.5, 1, 2.5, 4.5 V (> 120 Ω)Type of bridge4-wire/6-wire
Full/half bridge (> 120 Ω),quarter bridge (120 Ω, 350 Ω)
Voltage
Range 0.1, 0.2, 0.5, 1, 2, 5, 10, 20, 50, 80 V
Accuracy ± 0.05 % max. input volt-age 80 V
Impedance 100 kΩ (> 5 V range)Diff. input yes
Signal current Range ± 20 mA, 4..20 mAAccuracy ± 0.1 %
Currenttransmitter Sensor supply 24 V (max. 40 mA)
Potentiometer3-wire conn.
Range 6.25, 12.5, 25, 50, 100% Accuracy ± 0.1 % Sensor supply 2.5 V
Thermocouples J,K(others opt.)
Range ±100, ±200, -200..+500,-200..+1000 °C
Accuracy ± 0.1 % (without CJC)
Pt100 Range ±100, ±200, -200..+500,-200..+1000 °C
Accuracy ± 0.1 %
ICP® sensors
Range 1, 2, 5, 10 Vmin. input fre-quency appr. 7 Hz
Accuracy ± 0.1 %Sensor supply 4 mA, 22 V
Frequencyanalog
Range 5, 10, 20, 50, 100, 200, 500 Hz,1, 2, 5, 10, 20 kHz
Accuracy ± 0.05 %Input voltage ± 0.02.70 V
Frequencydigital
Range5, 10, 20, 50, 100, 200, 500 Hz, 1, 2, 5, 10, 20, 50, 100, 200, 500kHz
Accuracy ± 0.05 %Input voltage TTL / CMOS (≥ 3.5 V)
Torque meter,Telemetry(Discriminator)
Range Free entry of mid frequency and stroke, max. 100 kHz
Accuracy ± 0.05 %Input voltage TTL / CMOS (≥ 3.5 V)
Incrementalencoder
Range Variable, set by no. of pulsesAccuracy ± 0.05 %Input voltage TTL / CMOSDirectionsense/sync
without, static, dynamic / with sync, without sync
PWM sensorsRange 100 Hz, 1 kHz, 10 kHz Accuracy ± 0.2 %Input voltage TTL / CMOS (≥ 3.5 V)
Block Diagram
Dimensions22,5 x 110 x 115 mm, (WxHxD)
Ordering Code1. 2.
SCC1 - -
1. Model with screw terminalsUni2 2 Universal channels (standard)
2. Option measuring channels/output1AOSK 1 universal channel, 1 analog output1CO only 1 universal channel via CAN
Thermocouples have to be connected via an adapter cable with in-tegrated CJC.
pi-F2-messverstaerker_e.odm V1.55-00 25
GHM GROUP - Standort Imtron | GHM Messtechnik GmbHCarl-Benz-Straße 11 | 88696 Owingen | GERMANYPhone +49 7551 9290-0 | Fax +49 7551 9290-90www.ghm-group.de | [email protected]
Product information Computer Controlled Measurement Amplifiers
26 pi-F2-messverstaerker_e V1.55-00
GHM Messtechnik GmbH - Location IMTRONCarl-Benz-Str. 11 D-88696 Owingen Germany Fon +49(0)7551/9290-0 Fax -90www.ghm-messtechnik.de [email protected] Controlled Measurement Amplifiers Test Bench Measurement
CAN StickUniversal amplifier supported by the Federal Ministry of Economics and Technology based on a resolution by the German Bundestag.
CharacteristicsThe SIQUAD CAN Stick offers computer-controlled signalconditioning of various sensors. It has 1 DSP per unit.There are 2 versions depending on the sensor require-ments. Signal output is digital via CAN. Protocol is CAN2.0B. Parameter setting is done with the software DaSoftvia a USB-to-CAN interface. Signal filtering can be config-ured from 3..2000 Hz at 20 kS/s sample rate.
Technical Data
General
Accuracy see sensorsChannels/unit 1, isolatedAD converter 24 bit / channelSample rate Appr. 20 kHz (51.2 µs)Band width Appr.5 kHz Digital output CANInput protection ± 100 V, ESD IEC 1000-4-2Supply voltage 9..36 V DC
Sensor supply 0.5, 1.0, 2.5, 4 V (50 mA), 24 V (40 mA)
Environmentaltemperature 0..+50 °C
Strain gaugebridges
Range 0.5, 1, 2, 4, 5, 10, 25, 50 mV/V Accuracy ± 0.03 % Sensor supply 0.5, 1, 2.5, 4.5 V (> 120 Ω)Type of bridge4-wire/6-wire
Full/half bridge (> 120 Ω),quarter bridge (120 Ω, 350 Ω)
Voltage
Range 0.1, 0.2, 0.5, 1, 2, 5, 10, 20, 50, 80 V
Accuracy ± 0.05 % max. input volt-age 80 V
Impedance 100 kΩ (> 5 V range)Diff. input yes
Signal current Range ± 20 mA, 4..20 mAAccuracy ± 0.1 %
Currenttransmitter Sensor supply 24 V (max. 40 mA)
Potentiometer3-wire conn.
Range 6.25, 12.5, 25, 50, 100% Accuracy ± 0.1 % Sensor supply 2.5 V
Thermocouples J,K(others opt.)
Range ±100, ±200, -200..+500,-200..+1000 °C
Accuracy ± 0.1 % (without CJC)
Pt100 Range ±100, ±200, -200..+500,-200..+1000 °C
Accuracy ± 0.1 %
ICP® sensors
Range 1, 2, 5, 10 Vmin. input fre-quency appr. 7 Hz
Accuracy ± 0.1 %Sensor supply 4 mA, 22 V
Frequencyanalog
Range 5, 10, 20, 50, 100, 200, 500 Hz,1, 2, 5, 10, 20 kHz
Accuracy ± 0.05 %Input voltage ± 0.02.70 V
Frequencydigital
Range5, 10, 20, 50, 100, 200, 500 Hz, 1, 2, 5, 10, 20, 50, 100, 200, 500kHz
Accuracy ± 0.05 %Input voltage TTL / CMOS (≥ 3.5 V)
Torque meter,Telemetry(Discriminator)
Range Free entry of mid frequency and stroke, max. 100 kHz
Accuracy ± 0.05 %Input voltage TTL / CMOS (≥ 3.5 V)
Incrementalencoder
Range Variable, set by no. of pulsesAccuracy ± 0.05 %Input voltage TTL / CMOSDirectionsense/sync
without, static, dynamic / with sync, without sync
PWM sensorsRange 100 Hz, 1 kHz, 10 kHz Accuracy ± 0.2 %Input voltage TTL / CMOS (≥ 3.5 V
Block Diagram
Dimensions165 x 25 x 35 mm (WxHxD)
Ordering Code1. 2.
SCC1 - -1. Model
Uni1 1 universal channel2. Terminal
BB7 7-pole Binder socket (standard)LB7 7-pole Lemo socket
Thermocouples have to be connected via an adapter cable (con-nector to TC-Mini) with integrated CJC
26 pi-F2-messverstaerker_e.odm V1.55-00
GHM GROUP - Standort Imtron | GHM Messtechnik GmbHCarl-Benz-Straße 11 | 88696 Owingen | GERMANYPhone +49 7551 9290-0 | Fax +49 7551 9290-90www.ghm-group.de | [email protected]
Product information Computer Controlled Measurement Amplifiers
27pi-F2-messverstaerker_e V1.55-00
GHM Messtechnik GmbH - Location IMTRONCarl-Benz-Str. 11 D-88696 Owingen Germany Fon +49(0)7551/9290-0 Fax -90www.ghm-messtechnik.de [email protected] Controlled Measurement Amplifiers Test Bench Measurement
SIQUAD Ethernet Compact Module UniCharacteristics
pi-F2-messverstaerker_e.odm V1.55-00 27
GHM GROUP - Standort Imtron | GHM Messtechnik GmbHCarl-Benz-Straße 11 | 88696 Owingen | GERMANYPhone +49 7551 9290-0 | Fax +49 7551 9290-90www.ghm-group.de | [email protected]
Product information Computer Controlled Measurement Amplifiers
28 pi-F2-messverstaerker_e V1.55-00
GHM Messtechnik GmbH - Location IMTRONCarl-Benz-Str. 11 D-88696 Owingen Germany Fon +49(0)7551/9290-0 Fax -90www.ghm-messtechnik.de [email protected] Controlled Measurement Amplifiers Test Bench Measurement
(Discriminator)Input voltage TTL / CMOS (≥ 3.5 V)
Incrementalencoder
Range Variable, set by no. of pulsesAccuracy ± 0.05 %Input voltage TTL / CMOSDirection sense/sync without, static, dynamic / with sync, without sync
PWM sensorsRange 100 Hz, 1 kHz, 10 kHz Accuracy ± 0.2 %Input voltage TTL / CMOS (≥ 3.5 V)
Block Diagram
DimensionsSEC1: 225 x 165 x 65 mm (BxHxT)
Ordering Code1. 2. 3.
SEC1 - - -
1. Sensor type with 1 amplifier unitUNI4 4 channel universal
2. TerminalBB7 7-pole Binder socket (standard)LB7 7-pole Lemo socket
3. Housing typeHL Box (Standard)LL FlangeTL DIN rail
28 pi-F2-messverstaerker_e.odm V1.55-00
GHM GROUP - Standort Imtron | GHM Messtechnik GmbHCarl-Benz-Straße 11 | 88696 Owingen | GERMANYPhone +49 7551 9290-0 | Fax +49 7551 9290-90www.ghm-group.de | [email protected]
Product information Computer Controlled Measurement Amplifiers
29pi-F2-messverstaerker_e V1.55-00
GHM Messtechnik GmbH - Location IMTRONCarl-Benz-Str. 11 D-88696 Owingen Germany Fon +49(0)7551/9290-0 Fax -90www.ghm-messtechnik.de [email protected] Controlled Measurement Amplifiers Test Bench Measurement
Ethernet Compact ModulesCharacteristicsThe SIQUAD Ethernet Compact Modules of-fer computer-controlled signal conditioning ofvarious sensors. There are sensor-specificamplifiers available with 1 DSP per amplifierunit. Signal output is digital via TCP/IP. Param-eter setting is done with the software DaSoft.Signal filtering can be configured from3..3000 Hz at 20 kS/s sample rate.
Technical Data
General
Accuracy see sensors
Channels/unit
4, 2x4, isolated(8, 2x8, isolated inputs with com-mon ground)
AD converter 24 bit / channelSample rate max. 20 kHzBand width max. 5 kHz Digital output EthernetInput protection ± 100 V, ESD IEC 1000-4-2Supply voltage 9..36 V DCEnvironmentaltemperature 0..+50 °C
Strain gaugebridges(DMS4)
Range 0.5, 1, 2, 4, 5, 10, 25, 50 mV/V Accuracy ± 0.03 % Sensor supply 0.5, 1, 2.5, 4.5 V (> 120 Ω)
Type of bridge full bridge, half bridge, (> 120 Ω)quarter bridge (optional, >120 Ω)
Voltage(DCU4)
Range0.01 / 0.02/ 0.05 / 0.1 / 0.2 / 0.25 / 0.3 / 0.5 / 0.6 / 1 / 2 / 5 / 10/ 20 / 50 / 100 V
max. input volt-age 100 V
Accuracy ± 0.03 %
Signal current(DCI4) Range
± 20 mA, 4..20 mA
Accuracy ± 0.05 %
Thermo-couples J,K(TC4-K, TC4-J)
Range -100 to +100, +200, +500, +1000(1200) °C
Accuracy ± 0.2 % (with CJC)
Pt100(Pt1004)
Range -100 to +100, +200, +500, +1000°C
Accuracy ± 0.1 %
ICP® Sensors(ICP4)
Range 1, 2, 5, 10 Vmin. inputfrequency appr.. 2 Hz
Accuracy ± 0.1 %Sensor supply 4 mA, 24 V
FU converterRange
5, 10, 20, 50, 100, 200, 500 Hz, 1, 2, 5, 10, 20, 50, 100, 200, 500,1000 kHz
resolution min. 12 bitmax. dynamics 10 kHz
Incrementalencoder
Range 100..106 pulsesresolution 16 bitmax. counterfrequency
1 MHz
Sensor supply
unregulated (± 15 %) 2 W (Socket)1 value: 3.3, 5, 9, 12, 15, 24 V
regulated (± 5 %) 3 W (soldered)1 value: 3.3, 5, 12, 15 V
Inputs as8 DI(opto decou-pled)(DIO8)
High-level + 3.5..60 VLow-level - 30..+1 V
Input current appr. 6 mA (0..30 V)6..36 mA (-30..+60 V)
max. input frequency
20 kHz
Inputs as FVconvertermax. 4(DIO8)
Range5, 10, 20, 50, 100, 200, 500 Hz, 1, 2, 5, 10, 20, 50, 100, 200, 500,1000 kHz
resolution min. 12 bitmax. dynamics 10 kHz
Inputs as In-cremental counter,max. 4(DIO8)
Range 100..106 pulsesresolution 16 bit
max. counterfrequency
1 MHz
Outputs as relay contacts(DIO8)
Switch currents max. 2 A or 10 ASwitch voltage max. 220 V DCSwitch power max. 60 WContact resist. 50 mΩmax. output frequency
appr.. 15 Hz
Switching cy-cles
mechanical min.108
electrical min. 105
Block Diagram
DimensionsSEC1: 130 x 250 x 45 mm, 130 x 130 x 45 mm (WxHxD)SEC2: 130 x 250 x 75 mm, 130 x 130 x 75 mm (WxHxD)
pi-F2-messverstaerker_e.odm V1.55-00 29
GHM GROUP - Standort Imtron | GHM Messtechnik GmbHCarl-Benz-Straße 11 | 88696 Owingen | GERMANYPhone +49 7551 9290-0 | Fax +49 7551 9290-90www.ghm-group.de | [email protected]
Product information Computer Controlled Measurement Amplifiers
30 pi-F2-messverstaerker_e V1.55-00
GHM Messtechnik GmbH - Location IMTRONCarl-Benz-Str. 11 D-88696 Owingen Germany Fon +49(0)7551/9290-0 Fax -90www.ghm-messtechnik.de [email protected] Controlled Measurement Amplifiers Test Bench MeasurementOrdering CodeOnly available at present:
1. 2. 3. 4.
SEC1 - -
1. Sensor type 1 amplifier unitDMS4 4 channels Strain GaugeICP4 4 channels ICPDCU4 4 channels VoltageDCI4 4 channels Signal CurrentTC4 4 channels Thermo CoupleFU2 2 channels frequency converterDIO8 8 channels Digital I/O
2. Connection(not all combinations sensor-socket type are possible!)BNC BNC socketBB5 5-pin Binder socketBB7 7-pin Binder socketLB7 7-pin Lemo socket
3. Housing typeHL Box (standard)LL FlangeTL Mounting rail
4. Option1/4 BR 1/4-bridge with 2 resistance values (120, 350 Ω)
switchable (DMS4 only)
1200 Range 1200 °C (TC4/TC8 only, only TC type K)
XG Sensor supply, regulated, soldered3.3, 5, 12, 15 V, ± 5 % (FU2 only)
XU Sensor supply, unregulated, socketed3.3, 5, 9, 122, 15, 24 V, ± 15 %(FU2 only)
2 Standard value, without option 12V unregulated will be shipped
30 pi-F2-messverstaerker_e.odm V1.55-00
GHM GROUP CORPORATE | GHM Messtechnik GmbHSchloßstr. 6 | 88453 Erolzheim | GERMANYPhone +49 7354 937233-76 | Fax +49 7354 937233-88www.ghm-group.de | [email protected]
Product information Computer Controlled Measurement Amplifiers
31pi-F2-messverstaerker_e V1.55-00
GHM Messtechnik GmbH - Location IMTRONCarl-Benz-Str. 11 D-88696 Owingen Germany Fon +49(0)7551/9290-0 Fax -90www.ghm-messtechnik.de [email protected] Controlled Measurement Amplifiers Test Bench Measurement
AD-ETH-250
Channels/unit 16AD converter 16 bitSample rate 250 kS/sTotal sample rate 1 MS/sDigital output Ethernet, (optional CAN)Input protection ± 50 V permanentDC input ± 10 VAccuracy 0.1 %Supply voltage +24 V / 150 mA, isolatedEnvironmental temperature 0..+70 °C
Block Diagram
Dimensions19“ plug-in unit, 3 U height, 5 U width, depth 160 mm
Ordering Code1. 2. 3.
AD-ETH - - -
1. Model250 16 channels DC ± 10 V, 19“ plug-in unit, sample rate
250 kS/s p. channel2. Option 1
BNC Box housing with 16 BNC sockets, power supply ter-minal
3. Option 2ICP 16 channels ICP with sensor supply in place of DC In-
put
pi-F2-messverstaerker_e.odm V1.55-00 31
GHM GROUP CORPORATE | GHM Messtechnik GmbHSchloßstr. 6 | 88453 Erolzheim | GERMANYPhone +49 7354 937233-76 | Fax +49 7354 937233-88www.ghm-group.de | [email protected]
Product information Computer Controlled Measurement Amplifiers
32 pi-F2-messverstaerker_e V1.55-00
GHM Messtechnik GmbH – Sales Center InternationalSchloßstraße 6 88453 Erolzheim Germany Fon +49-7354-937233-0 Fax -88www.ghm-messtechnik.de [email protected]
Product Information Test Bench MeasurementProduct Overview
„Industrial Sensors and Instrumentation“
„Process Instrumentation “Hygienic Design“GHMadaptTemperature FlowLevel / Filling HeightAnalysis
“Laboratory Instrumentation“
„Industrial Electronics“Displays / ControllerTransmitter / Signal conditioningIsolating convertersSafety and Monitoring DevicesPower ElectronicsCalibration and Testing
“Measuring Data Acquisition“Data Logging and MonitoringTest Bench Measurement TechnologyRenewable Energies