GEYSAIRADDENDum owNER’ S mANu Al - · PDF fileHorizontal – Anchoring Point...

Click here to load reader

  • date post

    04-Jun-2018
  • Category

    Documents

  • view

    212
  • download

    0

Embed Size (px)

Transcript of GEYSAIRADDENDum owNER’ S mANu Al - · PDF fileHorizontal – Anchoring Point...

  • GEYSAIRTM ADDENDum to the owNERS mANuAlIMporTanT InforMaTIon for The InsTaller and The owner

    INcluDED: TherMoMasseur wITh GeysaIrTM InsTallaTIon

    Imp

    oR

    tAN

    t: t

    o b

    E k

    Ep

    t f

    oR

    th

    E o

    wN

    ER

  • geysairtm addendum to the owners manual

    3 www.bainultra.com Printed in Canada. Copyright september 2012 Bainultra inc. all rights reserved. 45100169some products, specifications, and services mentioned in this manual are described in pending patent applications or are protected by patents.

    table of contents

    safety instructions 4

    tHerMoMasseur

    ayoura freestanding 5

    amma freestanding 6

    Balneo - naos & sanos - installation 7 - 8

    Balneo - Cella - installation 9

    origami freestanding installation 10 - 11

    essenCia oval 7236 - Parts and tools - installation 12 - 13

    essenCia reCtangular 6838 - Parts and tools - installation 14 - 15

    turBine

    teChniCal sPeCifiCations 16

    eleCtriCal installation & PlumBing 17 - 19

    remote mounting 20

    tHe Mia series controls

    miaPlus - user guide 21 - 22

    trouBlesHooting 23

    warranty 24

    956, chemin oliviersaint-nicolas (Qubec)g7a 2n1

    t 418.831.7701 1.800.463.2187

    f 418.831.6623 1.800.382.8587 [email protected]

  • 4 supercede page 4 of owners Manual

    geysairtm addendum to the owners manual | SAFETY INSTRUCTIONS

    InstRUctIons PeRtaInInG to a RIsK of fIRe, electRocUtIon, oR PeRsonal InJURY

    iMportant safety instructionsreaD anD follow all instructionssaVe tHese instructions

    risk of hyperthermia; people using medication and/or having an adverse medical history should consult a physician before using a hydro-thermo massagetm bathtub equipped with a heater.

    risk of hyperthermia and possible drowning: do not use a hydro-thermo massagetm bathtub equipped with heater immediately follow-ing strenuous exercise.

    risk of fetal injury; pregnant or possibly pregnant women should consult a physician before using a hydro-thermo massagetm bathtub equipped with a heater.

    risk of accidental injury or drowning; do not use drugs or alcohol before or during the use of a hydro-thermo massagetm bathtub equipped with a heater.

    use this unit only for its intended purposes or as described in this manual. use only attachments recommended by the manufacturer. risk of hyperthermia and possible drowning. water temperature in excess of 100f (38c) may be injurious to your health. Check and

    adjust temperature before use. to reduce the risk of injury, as with any other conventional bath, do not allow children or physically impaired people to use this unit

    unless they are closely supervised at all times. to avoid injury, exercise care when entering or exiting the thermomasseur. the geysair (option) should always be connected to the hot water intake. if it is not the case, then, the geysair option should be

    deactivated via the bath control.

    risK of eleCtriCal shoCK disconnect electric power before servicing. do not permit electrical appliances (hair dryer, lamp, telephone, radio, television, etc.) within 5 (1.5 m) of the thermomasseur. Before using the thermomasseur, its exterior construction (podium or skirting) should be finished so that a bather cannot accidentally

    come in contact with electrical components (turbine and power module). for indoor use only.

    eleCtriCal ConneCtions: never drop or insert objects into any openings. the thermomasseur must be connected only to a supply circuit that is protected by a 15 amp class a ground fault circuit interrupter

    (gfci) for baths with 1 heated backrest and a 20 amp (gfci) for baths with geysair or for baths with 2 heated backrests of the amma series. this interrupter is supplied by a certified electrician and must be tested on a regular basis in accordance with manufac-turers instructions. the gfCi ground must be connected. if defective, do not use the thermomasseur. disconnect immediately and call a certified electrician.

    use 12 awg (or greater) copper conductors that resist temperatures of at least 194f (90c). Canada only: for permanently connected units. a green-colored terminal (or a wire connector marked g, gr, ground or grounding) is

    provided within the terminal compartment (not applicable if unit supplied with an electric plug). to reduce the risk of electrocution, connect this terminal or connector to the grounding terminal of your electric service or supply panel with conductor equivalent in size to the circuit conductors supplying the equipment and be 12 awg or more.

    all electrical connections must be carried out by a certified electrician and must respect federal, provincial/state, and localbuilding codes and regulations.

    install in accordance with manufacturers installation instructions. for geysair-equipped baths using remote turbine installation (not mounted on the bath), grounding continuity must be tested

    between the bath grounding terminal and the bath power supply. failure to perform the grounding continuity test could result in serious personal injury.

    warning

    1 800 463.2187 From 8 a.m. to 8 p.m. Monday to Thursday (EST) From 8 a.m. to 5 p.m. on Friday (EST) Printed in Canada. Copyright July 2013 Bainultra inc. all rights reserved. 45100169

    some products, specifications, and services mentioned in this manual are described in pending patent applications or are protected by patents.

  • tHERMOMASSEUR | geysairtm addendum to the owners manual

    www.bainultra.com Printed in Canada. Copyright July 2013 Bainultra inc. all rights reserved. 45100169some products, specifications, and services mentioned in this manual are described in pending patent applications or are protected by patents.

    tH

    ER

    MO

    MA

    SSE

    UR

    supersedes page 20 of owners Manual 5

    aYoURa fReestandInGinstallation

    1. Bath site

    2. installation

    1-1 once floor is prepared and level and recess is cleared around the drain, place installation template on floor in the chosen location.

    1-2 align template overflow drain hole with floor drain and make sure recess around drain matches required measurements.

    1-3 mark anchor screw entry points on the floor.

    1-4 remove template and screw anchors where specified.

    TEMPLATE:

    AYOURADimensions: 1/4" [6mm]

    12"

    20"

    1-11-2

    2-3

    ayoura freestanding - installation

    2-1 unscrew both screws on access panel under the lip and gently remove panel.

    2-2 Complete installation of bath drain. make sure it is watertight.

    2-3 install bath on anchors.

    2-4 Connect drain and water supply and finish wiring.

    2-5 for geysair-equipped baths, the geysair unit must be connected to the hot water supply with a 3/8 male compression or 1/2 male nPt hose bibb. a t and a valve (not supplied) must be installed at the hot water intake.

    2-6 reinstall access panel.

  • geysairtm addendum to the owners manual | tHERMOMASSEUR

    1 800 463.2187 From 8 a.m. to 8 p.m. Monday to Thursday (EST) From 8 a.m. to 5 p.m. on Friday (EST) Printed in Canada. Copyright July 2013 Bainultra inc. all rights reserved. 45100169

    some products, specifications, and services mentioned in this manual are described in pending patent applications or are protected by patents.

    6 supersedes page 21 of owners Manual

    amma freestanding - installation

    amma fReestandInGinstallation

    1. Bath site

    2. installation

    2-5

    1-1

    1-2

    2-6

    1-1 once floor is prepared and level and recess is cleared around the drain, place installation template on floor in the chosen location.

    1-2 align the template overflow with the floor drain and ensure that the recess around the drain is properly measured.

    1-3 use a 3/16 bit to drill anchor screw entry points.

    2-1 mount drain on bath. ensure watertightness.

    2-2 Position the bath, aligning anchor holes with anchor screw entry points.

    2-3 Connect bath drain and water supply, and complete electrical wiring.

    2-4 for geysair-equipped baths, the geysair unit must be connected to the hot water supply with a 3/8 male compression or 1/2 male nPt hose bibb. a t and a valve (not supplied) must be installed at the hot water intake.

    2-5 once the bath is in place and all connections completed, secure bath in place using washers and screws supplied.

    2-6 install base.

    TH

    ER

    MO

    MA

    SSE

    UR

  • tHERMOMASSEUR | geysairtm addendum to the owners manual

    tH

    ER

    MO

    MA

    SSE

    UR

    www.bainultra.com Printed in Canada. Copyright July 2013 Bainultra inc. all rights reserved. 45100169some products, specifications, and services mentioned in this manual are described in pending patent applications or are protected by patents.

    supersedes page 22 of owners Manual 7

    2. installation

    balneo - naos & sanos installation

    1. Bath site

    1-1 once the floor has been finished and is perfectly level, place thermomasseur in the exact chosen location. trace the outline of the bath with an erasable marker.

    1-2 remove the thermomasseur and carefully place it upside down on a blanket or corrugated cardboard (ex. the box in which it was delivered).

    1-3 on the floor, determine by referring to measurements taken underneath the bath, the exact location of the drain, the air pipe, and the two anchoring points at each end of the bath.

    Balneo - naos & sanos - installation

    2-1

    2-2

    2-3

    1-1