GENERAL REQUIREMENTS - Lee & Associates...2015/04/13 · GENERAL REQUIREMENTS GENERAL REQUIREMENTS...
Transcript of GENERAL REQUIREMENTS - Lee & Associates...2015/04/13 · GENERAL REQUIREMENTS GENERAL REQUIREMENTS...
GENERAL REQUIREMENTSGENERAL REQUIREMENTSWork performed shall comply with the following:1.
2.
3.
4.
6.
7.
8.
9.
10.
11.
12.
13.
14.
5.
ASSUMED
1.
DESIGN CRITERIASOILS
SOILS REPORT NO. ####_###, DATE: 00/00/00, Soil Bearing Pressure: #### PSF
3.
LATERAL LOADS:2.
Roof LoadDESIGN LOADS:
TYPICAL FLOOR SHEATHING
B.N.:10d common nails at 6" o.c.E.N.:10d common nails at 6" o.c.F.N.:10d common nails at 12" o.c.
TYPICAL ROOF SHEATHING
B.N.:8d common nail at 6" o.c.E.N.:8d common nail at 6" o.c.F.N.:8d common nail at 12" o.c.
LUMBER GRADES ( U.N.O. )6x & 8x posts / beams / headers: DFL #14x posts / beams / headers: DFL #22x joists / rafters: DFL #2Studs: D.F.L. Stud Grade (up to 9'-0"), DFL #2 (taller than 9'-0")Top plates & Mud sills: DFL construction grade or better
4.
5.
6.
See structural wood note #11 for additional mud sill requirements
These General Requirements unless otherwise noted on plans or specifications.
All applicable local, State and Federal Codes, Ordinances, Laws, regulations and ProtectiveCovenants governing the site of work.
Standard Specifications of ASTM as noted herein and as required by the Building Code.
All work needs to be performed by qualified and experienced contractors familiar with this type ofproject.
On site verification of all dimensions and conditions shall be the responsibility of the contractorand sub-contractors. Noted dimensions take precedence over scale of drawings.Engineer or architect of record is to be notified immediately by the contractor should any questionarise or any discrepancy be found pertaining to the working drawings and/or specifications.
No deviations from these requirements and structural details shall be made without the writtenapproval of E.O.R.. Approval by the inspector does not constitute authority to deviate from plansor specifications.
The design, adequacy, and safety of erection bracing, shoring, temporary supports, etc., is the soleresponsibility of the contractor, and has not been considered by the architect or engineer. Thecontractor is responsible for the stability of the structure prior to the application of all shear walls,roof and floor diaphragms, and finish materials. The contractor shall provide the necessary bracingto provide stability prior to the application of the aforementioned materials. Observation visits tothe site by the architect or structural engineer shall not imply the assumption of any responsibilityin this regard.The builder has requested, contracted with and is compensating E.O.R. for the limited services ofproviding the minimum structural engineering drawings required, when combined with the otherbuilders' consultants drawings, to obtain a building permit for this project. These drawings are notintended to, nor do they detail all conditions, identify all materials, or define or limit the scope ofwork required to complete the project. The builder has requested, accepted, and represented thatthe he will select all materials and manufacturers, qualify and select all installers, direct all ways andmeans of construction, and provide all subcontractors additional information, above and beyondthese drawings, required to complete the project in conformance with all governing agencies andthe work will meet or exceed accepted industry standards.
Special inspection per Building Code Sec.1704 is required & applies to the types of work indicatedon sheet GNB (Note: Special inspectors qualification and responsibilities should comply withBuilding Code Section 1701 Requirements.)
Structural analysis for this project is done per applicable Building Code at the time of designconsidering standard of care.
Upon completion of above by the engineer & prior to start of construction, contractor is responsibleto check all dimensions, coordinate with the work of other consultants & other trades to ensurecompliance with his/her requirements.
Foundation engineering has been predicated on data and recommendations contained in the soilsreport by:
This report is considered part of the calculations and construction documents and is to be adheredto in all of its recommendations and requirements. Verify minimum foundation depth, width, reinforcing steel and additional expansive soil requirements with valid soils report and if they areany more restrictive, then they shall supersede the E.O.R. mins.
Use ring or screw shank nails and glue sheathing to framing using adhesives meeting APAspecification AFG-01 or ASTM D3498. Apply glue in accordance with manufacturer'srecommendations.As an alternate to 10d common nails, the following fastners can be used: Grabber plywood screws(ICC-ER-5280), or Simpson Strong-Tie quick drive screws (ICC-ER-1472), min 2" long @ 6" o.c. B.S.,@ 6" o.c. E.S. and 12" o.c. F.S.
*Note: All structural rated panels must be stamped by one of the following approved agencies,APA, PFS/TECO or Pittsburg.
15/32" APA rated sheathing Exp 1 with a min. panel index of 32/16.Refer to NER 108 for installation and conditions of use.
23/32" APA rated Sturd-I-Floor T&G Exp I with min. span rating of 24"o.c. Refer to NER 108 for installation and conditions of use
Building Code - CBC 2013
In case of conflict, the more stringent requirement shall govern.
15. E.O.R. shall have no liability for waterproofing or moisture transmission issues, whether related toconcrete slabs, footings, foundations, or otherwise. Owner, Soils Engineer and Contractor shall beentirely responsible for such issues, and will defend and indemnify E.O.R. against all such claims.
Total Design Base Shear:Basic Seismic Force Resisting System:Analysis Procedure: Equivalent lateral force procedure
X XPlywood Shear Walls
; VX =VY =
7. The following beams/headers/rims can be from any manufacturer with current approved icc es -evaluation report with the following mechanical properties:
For"LVL" & "PSL" beam: Fb = 2900 psi (MIN), Fv = 290 psi (MIN), E = 2.0 x 106 psi (MIN). For "LSL" beams/headers: Fb = 2325 psi (MIN), Fv = 400 psi (MIN), E = 1.55 x 106 psi (MIN). For manufactured rim board with min 1 1/4" thick, continuously supported by wall, and matches
joist depth: Fc I (Perpendicular)........ = 680 psi (MIN)
Fc // (Parallel)..................... = 1400 psi (MIN)
Ft = 1075 psi (MIN), E = 1.3 x 10
6
psi (MIN)
GLU-LAM beam shall be 24F-V4, DF/DF, U.N.O. on plans.
Fb = 2400 psi @ BOTTOM, Fb = 1850 psi @ TOP
Fv = 265 psi (MIN), E = 1.8 x 10
6
psi (MIN).
Total = 40 psfLive Load = 20 psfDead Load = 20 psfRoof Load
C110 MPHWind Speed:
Wind Exposure:Site Class =
Occupancy Category: II
D0.8650.335
0.6650.386
Seismic Design Category: DSeismic Importance Factor (I) =
0.136.5
0.136.5S1 : SD1 :
SDS :SS :RY :CSY :
RX :CSX :
1.0
Total = 55 psfLive Load = 40 psfDead Load = 15 psfFloor Load
Total = 55 psfLive Load = 40 psfDead Load = 15 psfDeck Load
SHEET INDEX
- Floor Framing Plan - Plan 1
- Foundation Plan - Plan 1
- General Notes & Requirements.
S-1.1
S-1.2
GN
SD-1
SD-2
- Foundation Details
- Structural Details.
- Roof Framing Plan - Plan 1S-1.3
- Foundation Plan - Plan 2-Lot 5S-2.1
S-2.2
S-2.3
- Floor Framing Plan - Plan 3 Lot 4
- Foundation Plan - Plan 3S-3.1
S-3.2
- Roof Framing Plan - Plan 3 Lot 4S-3.3
- Structural Details & Notes.GF
SD-3 - Structural Details.
- Partial Framing Plan - Plan 2-Lot 6S-2.4
- Floor Framing Plan Plan 2-Lot 5
- Roof Framing Plan Plan 2-Lot 5
- Partial Framing Plan - Plan 3 Lot 3S-3.4
- Partial Foundation Plan - Plan 2 - Lot 6S-2.1A
SD-4 - Structural Details.
- Structural Details & Notes.GD
SD-1A - Foundation Details
STRUCTURAL STEEL
1.GENERAL
MATERIALS2.
3.
5.
Steel pipe shall conform to ASTM A53, Grade B (Fy=35 ksi).
Rectangular and square HSS tubing shall conform, to ASTM A500, Grade B (Fy=46 ksi).
GENERAL REQUIREMENTS
6.
WELDS9.
7.
All structural steel materials and construction shall conform to the requirements specified inBuilding Code, Chapter 22 & Reference.
Steel shall be primed with a rust resistance primer & should conform to ASTM A36 (fy=36 ksi) asa minimum, unless otherwise noted. All W shapes to be ASTM A992. (fy=50 ksi)
All structural welding procedures and materials shall conform to Building Code, Section 2204.1.All welding shall be by the shield metal arc welding process or the submerged arc welding processusing E7OXX-low hydrogen electrodes, unless otherwise noted.All bolts for connections of steel members shall conform to Building Code, Section 2204.2 &ASTM A325N, unless otherwise noted. Holes for bolts should be drilled or punched & shall be1/16" larger than bolt diameter.
All shop welding and fabrication must be done in a shop approved by a special inspection agencywhich is approved by the Building Official. All field welding must be performed by a certifiedwelder and a special inspector shall continuously inspect all structural field welding. Both shall beapproved by the Building Official.
4. Round HSS tubing shall conform to ASTM A500 Grade B ( Fy=42 ksi )
8. Prefabricated steel moment frames per manufacturer. Steel moment frame manufacturer shallsubmit shop drawing, design calculations, and approved moment frame test report (ICC, IAMPO,or test per Appendix S of AISC SEISMIC PROVISION) to E.O.R. for review.
STRUCTURAL WOOD
17.
18. All ledgers shall be spliced with ST22 strap, unless noted otherwise.19.
26.
27.
28.
29.
30.
32.
33.
34.
a. Identity of the company manufacturing the truss.b. The design load.c. The spacing of the trusses.
35.
Truss manufacturer is responsible for: a. providing additional shear and drag trusses as shown on the framing plans.
31.
c. meet the profile as indicated in the architectural and structural drawings.
24.
25.
MINIMUM QUALITY1.
2.
3.
4.
5.
6.
FRAMING9.
10.
12.
13.
14.
15.
16.
8.
Do not bend the Simpson PA straps.7.
11.
20.
21.
22.
23.
8d COMMON
8d SINKERØ= 0.113 - L= 2 3/8"
Ø= 0.148 - L= 3"10d COMMON
Ø= 0.148 - L= 3 1/4"16d SINKER
Ø= 0.162 - L= 3 1/2"16d COMMON
Ø= 0.12 - L= 2 7/8"10d SINKER
ACTUAL NAIL SIZE ILLUSTRATION
All structural wood shall be of Douglas Fir Larch species, (19% maximum moisture content at thetime of construction U.N.O.).All machine bolts shall conform to ASTM A307. Holes for bolts should be drilled 1/16" larger thanbolt diameter.For non-shear wall applications, round washers shall be used on all bolts and should conform withANSI/ASME B 18.22.1. Use min. 1 3/8" Ø x 7/64" thick washer for 1/2" Ø bolt, 1 3/4" Ø x 9/64"thick washer for 5/8" Ø bolt and 2 1/2" Ø x 11/64" thick washer for 1" Ø bolt. U.N.O.All nails shall be sinker nails and staggered U.N.O., except as shown in Nailing Schedule.
Adhesive used to attach floor sheathing to framing elements shall conform with APA specificationAFG-01.Manufactured hardware specified on the drawings are to be Simpson Strong Tie (Unlessspecifically authorized in writing by E.O.R. Consulting Group). Follow all manufacturer'srequirements & recommendations for installation & handling of the product.
Fasteners specified on the drawings may be colored using manufacturer's brands that utilize thecolor coded system. Follow all code and manufacturer's requirements/recommendations forinstallation & handling of the products.
Ø= 0.131 - L= 2 1/2"
All framing, bracing, nailing, notching, drilling or boring shall be in accordance with Building Codeunless more stringent requirements are specified or required by the local Jurisdiction.Fabrication and handling of Glue-lam beams shall be per ANSI/AITC A 190.1 . Standard beams tobear legible APA-ENS or AITC grade stamp. An APA- EWS CRAN AITC Certificate of conformancefor glued-laminated members should be submitted to the field inspector prior to installation andGlue-lam members shall be 24F-V4, DF/DF with standard camber on roof beams except cantileverend (U.N.O.). All cantilever ends and floor beams shall have zero camber u.n.o. All beams shall befabricated using waterproof glue.Fasteners in contact with preservative treated lumber and fire retardant treated wood shall be ofhot-dipped zinc-coated galvanized steel, stainless steel, silicon bronze or copper.Exception: Plain carbon steel fasteners in sbx/dot and zinc borate preservative-treated wood in aninterior, dry environment shall be permitted.Stud walls perpendicular to a concrete or masonry wall shall be bolted to the concrete or masonrywall with 5/8" diameter x 8" A307 bolts at top, mid-height and bottom.Structural information shown on framing plans is for the main structural elements. Non-structuralelements shall be constructed per approved code requirements.Conventional light framed construction requirements of chapter 23 should be followed as required.
Weight of the roof tile is considered to be 10 psf max. (total roof dead load of 19 psf). If roofingmaterial exceeds this load, the framing contractor should notify E.O.R. in writing prior toconstruction.
Top plates of all wood stud walls to consist of (2) 2x's the same width as the studs U.N.O. Top platesshall lap a min. of 48" and be spliced with not less than 6-16d nails spaced not more than 12" o.c.
All shear panels shall have continuous sheathing material from one end to the other and fromplate to plate as specified on the drawings. Contractor shall coordinate framing such thatcontinuity of shear panels is assured.
All shear transfer nailing shall be per drawings, and contractor shall provide proper notificationfor inspections to review the same.Provide post/multiple studs at lower floor under post/multiple studs above. Each post/stud shallbe fastened by Gypsum Wall Board w/ 5d cooler nails @ 7" o.c. U.N.O. on plan. Provide full widthand depth compression block between floors at such locations.All joist hangers shall be Simpson U hanger, all beam hangers shall be Simpson HU hangers U.N.O.on plan or detail. Follow manufacturer's recommendations for installation.If a double sill plate is used at light-weight concrete flooring, then the framing contractor shallapply sill plate nailing to both sill plates, at 16" o.c. max. or as specified per schedule.
Headers: Use 4X4 for openings less than 16" at bearing walls without point loads. For non-bearingwalls use 2x4 for openings up to 3'-0" max. Use (2)2x4 for openings up to 6'-0" max. Use 4x6 foropenings up to 12'-0" max. U.N.O. (2-2x on edge can be substituted for 4x members).Approved end-jointed lumber may be used interchangeably with solid sawn members of the samespecies and grade for buildings up to 2-story. When finger jointed lumber is marked "stud useonly" or "vert use only" such lumber shall be limited to use for studs only. All finger jointedlumber should bear a certified finger jointed lumber grade stamp.Wood truss manufacturer shall supply to the engineer and the building department calculationsand shop drawings for approval of design loads, configuration (2 or 3 point bearing), and sheartransfer, prior to fabrication. It shall be the responsibility of the manufacturer to obtain buildingdepartment approval of calculations and shop drawings prior to fabrication.Trusses shall be designed in accordance with the latest local Building Code for all loads imposed,including lateral loads and mechanical equipment loads.All connections involving trusses shall be ICC approved and of adequate strength to resist stressesdue to the loadings involved and shall be designed and specified by the truss manufacturer.
Cross bridging and/or bracing shall be provided and detailed by the truss manufacturer asrequired to adequately brace all trusses.Truss manufacturer to provide details which allow for normal deflection without imposing lateralloads on their supports (i.e., scissors trusses).
b. reviewing framing plans and details prior to fabrication of trusses and specifying hangers.
d. design trusses for deflection compatibility of the system to avoid hump and sag in roof or ceiling.All trusses designed by truss manufacturer shall be designed to sustain all vertical, lateral andother pertinent loads, including bracing of top and bottom chords, in addition to any connectionsrelated to trusses. Contractor to coordinate with truss manufacturer.All truss lumber shall be Douglas Fir Larch (U.N.O.). Roof truss lumber shall be either Douglas FirLarch or Hem-Fir. (U.N.O.)Each truss shall be legibly branded, marked or otherwise have permanently affixed thereto thefollowing information located within two feet of the center of span on the face of the bottom chord:
Total load and live load vertical deflections for roof member shall be limited to max. L/240, andL/360 U.N.O. Total load and live load vertical deflections for floor member shall be limited to max.L/360, and L/480 U.N.O.
- No multiples of2x4"s areallowed tospan morethan 14'-0".Bearing wallsexceeding10'-0" must bedesigned caseby case.
Use this span table for stud spacing (U.N.O. on plans):
REINFORCED CONCRETE
1.
2.
GENERAL
MATERIALS
3. Concrete aggregates shall conform to Building Code Section 1903.
CONCRETE MASONRY
1.GENERAL
STRENGTH
SPECIAL INSPECTION
8.
9.
STRENGTH7.
10.
11. Min. concrete cover for reinforcing:a- Concrete, placed against earth not formed - 3"b- Concrete formed or troweled - 2"c- Walls and curbs - 1 1/2"d- Slab on grade - at center
9.
Dowels shall be equal in size and spacing.
4.
6.
All concrete masonry materials and construction shall be in accordance with Building Code,Chapter 21.
The specified compressive strength of masonry, f'm, shall be 1500 psi, unless noted otherwise.
Special inspection for concrete masonry construction shall be carried out in accordance withBuilding Code Section 1704 and requirements in Special Inspection tables on sheet GN. Masonrycompressive strength, f'm shall be verified by Unit strength method or Prism test method prior toand during construction as described in Building Code, Section 2105.
All reinforced concrete materials and construction shall conform to Building Code, chapter 19.
Cement shall conform to Section 1903 of Building Code and shall correspond to that on which theselection of concrete proportions were based.
Portland cement shall be Type I or II conforming to ASTM C150. For concrete in contact with soilcontaining sulfate So4 ≥ 0.1% by weight use Type II cement, containing sulfate So 4 ≥ 0.2% by weightuseType V cement. Weight percentage of So 4 shall be per soils report. Refer to Section 1904 of theBuilding Code for special exposure conditions as required by soils engineer & see corrosionengineer's recommendations for concrete exposed to corrosive elements.Reinforcing steel shall conform to ASTM A615. Grade 40 for sizes #3 and #4 and grade 60 forsizes #5 and larger.
The (28 days) concrete compressive strength, f'c, shall be min 2500 psi U.N.O.
Special inspection is required for concrete with f'c > 2500 psi unless the use of concrete withf'c > 2500 psi is solely for item #8 above.All reinforcing, dowels, holdowns, and other inserts shall be secured in position and approved bythe local building official prior to the pouring of any concrete.
5.
2.MATERIALS
3.
4.
6.
7.
5.
All materials making up finished concrete masonry construction shall conform to standardsrequired by Building Code Sec. 2103.
Grade N concrete bricks are for use as architectural veneer and facing, limited to in exterior walls.
Grade S concrete bricks are for general use where moderate strength and resistance to frostaction and moisture penetration is required.
Concrete masonry units shall conform to ASTM C90 for load bearing concrete masonry units.Concrete brick shall conform to ASTM C55, Specifications for Concrete Building Brick.
Grout shall comply with Article 2.2 & 2.6 of TMS 602-08/ACI 530.1-08/ASCE 6-08 and shall attain aminimum compression strength at 28 days of 2000 psi or the required compression, f'm, whicheveris greater. The compressive strength of grout shall be determined in accordance with ASTM C-1019.
8. The (28 days) concrete compressive strength, f'c, for concrete in contact with soil with weightpercentage of sulfate (So4) ≥ 1.0 shall be 4000 psi, and with weight percentage of sulfate (So 4)≥ 2.0 shall be 4500 psi. Special inspection is not required.
DEFERRED APPROVAL:
2.
3.
1. Elements of structure that are marked "by others" shall be excluded from this work permit.
General contractor shall first submit separate drawings for the above elements to the EOR fortheir review and if approved, then submit to the building officials for their review and approval.
City approval shall be obtained prior to installation of element subjected to deferred approval.
14.
Floor slab shall be poured level to 1/8" in 10'.15.16.
17.
18.
20.
19.
21.
23.
22.
1.
2.
4.
3.
MISCELLANEOUS
Prior to the contractor requesting a Building Department foundationinspection, the soil engineer shall advise the building official in writing that:a. The building pad was prepared in accordance with the soil report.b. The utility trenches have been properly backfilled and compactedc. The foundation excavations, the soils expansive characteristics and
bearing capacity conform to the soils report.
All grade beams shall be poured monolithically for their entire length.
a. Do not walk on slab until 24 hours after concrete has been poured.b. Begin wall framing 4-5 days after concrete poured.c. Begin roof/floor framing 7-10 days after concrete poured.d. Do not load roof prior to 14 days after concrete poured.
SHEET ROCK ON FRAMING5.
5/8" : 16 individual 4x10 sheets (8 pairs of sheets)1/2" : 20 individual 4x10 sheets (10 pairs of sheets)
foundations, walls and slab have attained sufficient strength to support lateral soil pressure.Concrete placement shall be monolithic in one continuous operation uniformly placed and mustbe vibrated and well consolidated unless shown otherwise on plans. Dual pour is defined by ACI asto when 1st. & 2nd. pour can not be vibrated together.
Requirements for pre-saturation of subgrade soils and daylight setback of exterior footings fromany descending slope shall comply with soil report recommendations.
Finish grade around the perimeter of slab shall be constructed such that rain and irrigation wateris drained away from the slab.All site and pad preparation, such as but not limited to shading, compacting of the fill,pre-saturation, and concrete slab base preparation, shall be performed in accordance with the soilengineer's recommendation and soils report.Foundation drawings prepared by E.O.R. reflect the structural requirements. Refer toarchitectural plans for dimensions, depressions, slope, shelves, patios, stoops and porches notshown in foundation drawings. Accuracy of the dimensions and final fit of the building shall bereviewed by the architect and the contractor prior to construction.
Waiting period for concrete slabs-on-grade prior to start of construction is as follows:
No pipes or conduits shall extend under isolated column footing or under continuous wallfootings unless specifically detailed or approved by the architect, structural engineer and thebuilding official.The contractor shall arrange for observation of the work by the soils engineer. The following arerequirements of the soils engineer:a. All footing excavations shall be inspected and certified in compliance with the soils report by
the soil engineer prior to placing of concrete or steel.b. Soil conditions, including compacting and moisture content, shall be inspected and certified to
be in compliance with the soil report by the soils engineer prior to placing of concrete or steel.c. A certificate of compliance shall be submitted to the building official prior to his foundation
inspection and to the architect and structural engineer.
Grout under base plates shall be non-shrink type and shall have compressive strength equal toor greater than the concrete or masonry supporting it.
All reinforcing to be accurately and securely located prior to pouring concrete or groutingmasonry.All horizontal reinforcement to have matching dowels at corners of walls. All verticalreinforcement to have matching dowels to footing, unless otherwise noted.
Stacked sheet rock loading shall be limited to the following quantities in any one room:
The shoring of the floor supporting stacked sheet rock is required if the number of sheet rockexceeds the quantities listed above.
6. Automatic sprinkler system specification & details by others
7. The contractor is responsible for taking measures to mitigate the effects of building shrinkage instructures consisting of 3 or more stories of wood framed construction. As an alternate, usekiln dried studs for top plates & sole plates of : The lower 3 levels of 5 story bldgs. The lower 2 levels of 4 story bldgs. The lower fiirst level of 3 story bldgs.
FOUNDATION1.
2.
3.
13.
4.
5.6.
7.
8.
10.
9.
12.
11.
Admixtures in concrete mix. containing calcium chlorides shall not be used.
1a.
1b.
All continuous footings to have 5/8"dia. x min. 12" anchor bolts, min. 7" embedment into concretefooting at 72" o.c. unless noted otherwise on plans. One anchor bolt should be located max. 12"away and min. 9 1/2" from the end of the sill plates. min. (2) A.Bs. per sill plate/shear panel. Sillplate under shear walls of up to 4'-0" in length must be continuous. See note 2 for sill platefasteners at interior non-shear walls.
Anchor bolts at shear walls shall be installed with plate washers of min. 3" sq. x 0.229" thickbetween sill plate and nut. Edge(s) of plate washers shall be 1/2" max. from inside face ofshear panel(s) per conditions shown below.The hole in the plate washer is permitted to be diagonally slotted with a width of up to 3/16inch larger than the bolt diameter and a slot length not to exeed 1 3/4 inches, provided astandard cut washer is placed between the plate washer and the nut.
For interior non-shear walls use Simpson PHNW series 0.145Ø pins with a penetration of 1 1/4"into slab at 16" O.C. to be installed in accordance with ICC ESR-2138. Actual slab thickness to beminimum 4". All interior shear walls to have A.Bs. per foundation plan.All holdowns and post anchors to be installed according to most current Simpson Strong Tiespecifications and requirements of ICC-ER reports & shall be tied in place prior to foundationinspection. Dimensions are not furnished to Simpson holdowns. It is the responsibility of thecontractor's superintendent, the framing contractor and the concrete contractor to locate theseanchors in the exact location. Refer to details for proper installation.Min. concrete width to be 8" for receiving PA, HPA & STHD's. Verify locations of holdowns andanchor bolts with rough framing to assure accurate installation.Provide #3 X 24" dowel at 24" o.c. and 12" from the corner at all concrete stoops and porches.Provide min. (1) #4 reinforcing for electrical ground, location to be verified with the electricalcontractor.Verify min. foundation depth, width, reinforcing steel and additional expansive soil requirementswith valid soils report and if more stringent, they shall supersede the above minimumrequirements. See note #7 under reinforced concrete for concrete strength.
Footings shall be examined and certified in writing by the project soil/geology engineer prior toinspection and placement of concrete.Concrete shall be to the strength and slump as specified per structural design, and consist ofPortland cement ASTM C-150 Type V per soils engineer's recommendations and Building Codesection 1904.3 (ACI 318 section 4.3) when exposed to sulfate containing solutions. Aggregatesshall be per ASTM C-33. Water to be clean and potable.
Placement shall be in one continuous operation unless otherwise specified. Slab surface shall becured with 'Hunts' compound or equal or cured with other methods in accordance with goodconstruction practice at contractor's option.Contractor shall dampen slab underlayment of sand/membrane just prior to concrete placementto assist uniform concrete curing. Slabs must not be poured during or immediately afterrainstorms. The specified sand over visqueen should not be saturated at the time of the concretepour. Any free water trapped in the sand layer must be removed prior to the concrete pour.The bottoms of footing excavations shall be level, clean and free of loose material or water whenconcrete is placed. Over excavation shall be filled with concrete or properly compacted fill thathas been tested and approved by the soils engineer. Backfill shall not be placed until supportingfoundations, walls and slab have attained sufficient strength to support lateral soil pressure.
1/2"MAX.
1/2"MAX.
EQ.
SHEAR PANELWHERE OCCURS
SW ANCHOR BOLTS AND PLATE WASHER ARRANGEMENT
ADJUST ⅊ WASHER SIZES
TO MEET NOTE 1a
REQUIREMENTS
2"EQ.
2x4 SHEAR WALLS ANDALL DOUBLE SIDED SHEAR WALLS
SINGLE SIDED SHEAR WALLS OF 2x6AND THICKER WALLS
1/2"MAX. ⅊ WASHER SIZES
PER NOTE 1a
CEILING JOISTS36.
NOTES: 1. COMMON NAILS SHALL BE USED (U.N.O.)
22. WIDER THAN 1" X 8" SHEATHING TO EACH BEARING, FACE NAIL...........................................3-8d21. 1" X 8" SHEATHING OR LESS TO EACH BEARING, FACE NAIL..................................................3-8d20. 1" BRACE TO EACH STUD AND PLATE, FACE NAIL....................................................................2-8d
18. CEILING JOISTS TO PARALLEL RAFTERS, FACE NAIL.............................................................3-16d17. CEILING JOISTS, LAPS OVER PARTITIONS, FACE NAIL...........................................................3-16d16. CONTINUOUS HEADER TO STUD, TOENAIL................................................................................4-8d
13. TOP PLATES, LAPS AND INTERSECTIONS, FACE NAIL............................................................2-16d
11. BLOCKING BETWEEN JOIST OR RAFTERS TO TOP PLATE, TOENAIL......................................3-8d
SOLE PLATE TO JOIST, AT BRACED WALL PANEL.......................................(3) 16d (BOX) PER 16"6. SOLE PLATE TO JOIST OR BLOCKING, FACE NAIL.......................................16d (BOX) AT 16" O.C.5. 2" SUBFLOOR TO JOIST OR GIRDER, BLIND AND FACE NAIL.................................................2-16d4. WIDER THAN 1" X 6" SUBFLOOR TO EACH JOIST, FACE NAIL..................................................3-8d3. 1" X 6" SUBFLOOR OR LESS TO EACH JOIST, FACE NAIL.........................................................2-8d2. BRIDGING TO JOIST, TOENAIL EACH END..................................................................................2-8d
NAILING SCHEDULE
25. 2" PLANKS....................................................................................................2-16d AT EACH BEARING
23. BUILT-UP CORNER STUDS.........................................................................................16d AT 24" O.C.
15. CEILING JOISTS TO PLATE, TOENAIL...........................................................................................3-8d
24. BUILT-UP GIRDER AND BEAMS....................................................................20d AT 32" O.C. AT TOP
19. RAFTER TO PLATE, TOENAIL........................................................................................................3-8d
9. DOUBLE STUDS, FACE NAIL............................................................................16d (BOX) AT 24" O.C.
8. STUD TO SOLE PLATE............................................................................................4-8d, TOENAIL OR
CONNECTION
14. CONTINUOUS HEADER, TWO PIECES.......................................................................16d AT 16" O.C.
12. RIM JOIST TO TOP PLATE, TOE NAIL.............................................................................8d AT 6" O.C.
10. DOUBLED TOP PLATES, FACE NAIL................................................................16d (BOX) AT 16" O.C.
1. JOIST TO SILL OR GIRDER, TOENAIL...........................................................................................3-8d
DOUBLE TOP PLATES, LAP SPLIC..............................................................................................8-16d
7. TOP PLATE TO STUD, END NAIL.................................................................................................2-16d
ALONG EACH EDGE
2-20d AT ENDS AND ATEACH SPLICE
AND BOTTOM AND STAGGERED
NAILING
3X SOLE: 2-20d (BOX)2X SOLE: 2-16d
Use this span table for ceiling joists given the following conditions (U.N.O. on plans):
2. JOIST CAN BE EITHER SAWN LUMBER OR I-JOIST PER PLAN
24"16"12"
2x4
7'-7"8'-10"9'-10"
A) Dead Load = 6.0 psfB) Live Load = 10.0 psfC) Total Deflection = L/240D) With one layer drywallE) Use #2 Douglas Fir Larch 24"
16"12"
12'-6"14'-5"16'-0"
24"16"12"
15'-9"18'-4"20'-5"
2x6 2x8SPACING MAX SPAN SPACING MAX SPAN SPACING MAX SPAN
2013 CALIFORNIA BUILDING CODE (1), (3)
(4)
(2)(1)
(3)
870
(PLF)SHEAR
220
PANELTYPE
SHEAR
8 d's
10 d's@ 2" O.C.
8 d's@ 2" O.C.
@ 3" O.C.
15/32" APA
Structural Irated
3/8" APArated
10 d's@ 12" O.C.
8 d's
@ 12" O.C.8 d's
@ 12" O.C.
8 d's@ 4" O.C.
NAILING(COMMON)
EDGE
8 d's@ 6" O.C.
3/8" APArated
rated3/8" APA
SHEATHING
8 d's@ 12" O.C.
@ 12" O.C.8 d's
FIELD
(COMMON)NAILING
STUDS ARE SPACED @ 16" O.C. MAX. UNLESS NOTED OTHERWISE ON PLAN.PERIODIC SPECIAL INSPECTION IS REQUIRED.
(4) (2)2
1
(5)(6)
USE CLIPS @ 6" O.C. ON SIMPSON STRONG WALL & HARDY FRAME (U.N.O.).
SINKER16d's
CONNECTIONSILL PLATE
@ 4" O.C.
@ 6" O.C.
@ 3" O.C.
@ 2" O.C.
@ 16" O.C.
@ 12" O.C.
@ 8" O.C.
@ 6" O.C.
@ 5" O.C.
SHEATHING PANEL JOINT AND SILL PLATE NAILING SHALL BE STAGGERED IN ALL CASES.PROVIDE 3" NOMINAL OR WIDER FRAMING AT ADJOINING PANEL EDGES WITH NAILS STAGGERED.
USE SPACING PER SCHEDULE IF NUMBER OF FRAMING CLIPS ARE NOT SPECIFIED ON FRAMING PLANS.
FRAMING CLIPS A35's,LS50's OR LTP4's
(5), (6)
2 ROWSSTAGG.
@ 3" O.C.
(4) (2)
(4) (2)
(4) (2)
1/4"Øx6"
SCREWSSDS(8)
260
320
380
410
490
(7) ALLOWABLE SHEAR ARE FOR STUDS SPACED @ 24" O.C. MAX.(8) SHEATHING CONFORMS TO EITHER DOC PS 1 OR PS 2 STANDARDS.(9) NAILING @ 6" O.C. WHEN STUDS ARE SPACED @ 24" O.C.
(9)
(7)
(7)
(7)
3/8" APArated 530
640 (7)
(10) FOR DOUBLE SIDED SHEAR PANELS:
(10) (10) (10)
(10) (10) (10)
(10) (10) (10)
a. USE HALF THE SPACING OF SILL PLATE FASTENERS STAGGERED FOR TYPE .b. USE ONLY 1/4"Øx6" SDS SCREWS IN SCHEDULE AND WITH HALF THE SPACING, FOR TYPES & .
3
4 5c. SEE SHEAR TRANSFER DETAIL ON PLAN FOR FRAMING CLIP TYPES AND SPACING, FOR TYPES , & .3 4 5
5/8" Ø
2XA.B. SPC'G
@ 24" O.C.
@ 16" O.C.
@ 8" O.C.
@ 8" O.C.
@ 6" O.C.
48"
42"
36"
24"
18"
SHEAR WALL SCHEDULE
1.
2.
3.
SHOP DRAWINGSSufficient copies of shop drawings for any member or product designed by entity other thanE.O.R. shall be submitted to E.O.R. prior to fabrication for review. Contractor shall submit shopdrawings of reinforcement for concrete masonry walls, concrete components with compressivestrength more than 2500 psi and structural steel to E.O.R. to review and obtain approval prior tofabrication. Shop Drawings shall be original drawings prepared for the project specificinformation, drawn accurately to scale. Direct copies and modified reproductions of the ContractDocuments will not be accepted. Allow sufficient time from the receipt of complete submittal forreview and processing by E.O.R..
Review of shop drawings by E.O.R. does not relieve the engineer responsible for the design or thecontractor from compliance with Building Code.
E.O.R.s review of the shop drawings consists of checking general conformance with structuraldrawings. Design accuracy of such product, dimensions and quantity of the product is notreviewed by E.O.R..
GN
GENERALDETAILS & NOTES
H.M. A.D.
PROJECT NAME:
ARCHITECT:
DEVELOPER:
ADDRESS:
PLOT DATE:
DESIGNED BY:
SHEET NAME:
SHEET NUMBER:
PROJECT NUMBER:
DESCRIPTIONDATENO.
REVISIONS
aBPa
RMO Greenfield Estates
M&O Investments
EL CAJON, CA
INGAMAC WAY
50011
04/13/2015
CHECKED BY:
BLDG. DEPT.03/31/20151
TYPICAL FRAMING ELEVATION
1/8"
1/2"MIN.
1/4"MIN.
3/8"MIN.
1/2"(TYP.)
3/8"(TYP.)
4 1/2"MAX.TYP.
1/4"MIN.
1/4" MIN.
1/8"GAP
CRIPPLEWALL STUD@24"o.c. MAX.
2x FLAT BLKG. @SHEAR WALL PLYWD.SPLICE w/ E.N.
TYPICAL BOUNDARY NAILINGMIN. 3/8" TO EDGE OF POSTSTUD & 3/8" TO EDGE OF PLYWD.
2X FLOATER
SOLE PLATE NAILINGPER PLAN
NO OVER CUT
OPEN'G
ROOF TRUSSPER PLAN.
TRUSS WEBMEMBERS
RADIUS ONCORNERSREQUIRED
2x TRIMMER w/ KINGSTUD ATTACHED w/16d @ 6"o.c. USE DBL.TRIMMER IF OPENINGIS GREATER THAN 8'-0"
2x FLOATERWHERE OCCURS
STUD WALL
DOUBLE SILL IFOPENING=8'-0"OR GREATER
HD TYPE HOLDOWNWHERE OCCURS
MIN. 3X POST AT VERT.SPLICES WHERESTAGGERED E.N.IS REQUIRED.
SILL PLATE EDGE
PLYWOOD EDGE
STAGGERED @ 3x ONLY
NO MORE THAN ONE HOLE ISALLOWED IN EA. HORIZONTALLINE. STAGGER HOLES IF SUCHCONDITION OCCURS. MAX OF(2)4 1/2"x4 1/2" CUTS AREALLOWED IN A 4'-0" WIDE PANEL.NO CUTS OR HOLES INSHEATHING WITHIN 16" OFCORNERS. FOR OPEN'GLARGER THAN 4 1/2"x4 1/2"CONTACT E.O.R.
(3)16d NAILS
1x4 X-BRACING w/(3)16d TO EA. MEMBER
TYPICAL1x4 LATERAL BRACING@ 48"o.c. OR AS SPECIFIEDBY TRUSS DESIGNER.
SIMPSON A35'S, LS50's ORLTP4's @ 48"o.c. MAX.U.N.O. PLANS.
SOLE PLATE NAILING @ 16"o.c.AT NON-SHEAR WALL & PERPLAN @ SHEAR WALL
RIM JOIST PER PLAN
TOP PLATE
TYPICALLTP4 EACH SIDE
HEADER PER PLAN, IF NOTCONT. USE SIMPSON ST6236
STAGGERED NAILING ATADJOINING PANEL EDGES@ 3X POST
NOTE:WHEN PLYWD SHT'G. IS NAILEDTO TRIMMER, ATTACH TO KINGSTUD w/ 16d SPACED TO MATCHSHEAR WALL E.N. SHEAR WALLNAILING HEADS SHOULD BEFLUSH WITH SHEAR PANEL.
TRIMMER OR POST PER PLANATTACH TO K. STUD w/ 16d@ 6"o.c. AT SHEAR WALLS AND@ 16"o.c. AT NON SHEAR WALLS
TRIMMER & KING STUDPER PLAN
2x FLOATER
INSTALL POST ANCHOR PER PLANON OUTSIDE FACE OF SHEARPANEL U.N.O. AVOID SHEAR WALLE.N. UNDER STEEL STRAP
SIMP. HDC WHEN OPENING@ EITHER SIDE EXCEEDS 5'-0"
P.T.D.F. SILL PLATE
2GD
2GD
11GD
NAILSTAGGEREDON OPPOSITESIDES OF GAP FOR 2x STUD
± 22 1/2"
4 1/4"TYP.
2"øMAX.
TYP. E.N.
A35 @ 16"O.C. FOR VENT SPACING OF 6'-0" (2-A35'sPER ADJACENT BLK's.), AND @ 12" O.C. FOR VENTSPACING OF 4'-0" (3-A35's PER ADJACENT BLK's.).SKIP A35's @ VENT BLOCKING
(3) BAYS OF FLATBLK'G. CENTERED@ SCREEN
ADJOINING FULL HT.BLK'G PER SHEARTRANSFER DETAILS
8d COMMON EDGE NAILS:@ 4"o.c. FOR VENT SPACING OF 6'-0"@ 3"o.c. FOR VENT SPACING OF 4'-0"
ALT. TO VENT BLOCK
C.L.
5"SCREEN FORVENTILATION
TYPICAL VENT BLOCK
SOLID RIM (2x,L.V.L. OR TIMBERSTRAND) w/ FULLBEARING. ADDBLKG. AS NEEDED
LOAD BEARING 4x4(MIN.) POST/MULTI-STUDS ABOVE
SOLID BLKG./POST,MULTI-STUD ORBEAM BELOW
HEADERPER PLAN
(4)16d, 2 AT TOP& 2 AT BOTTOMEACH SIDE
"I" JOIST W/ FULLBR'G. & 2x SQUASHBLK'G. ADDFILLERSAS NEEDED
BLOCKING AT POSTS/TRIMMERS
PERPENDICULAR PARALLEL
SIMP. STC @EACH CONNECT(MAX. @ 24"o.c.)
BOT. CHORDOF TRUSS
Ix OVER 2x PLATEOR (2)2x TOP PLWHEN TRUSS BOT.CHORD IS CAMBERED
Ix OVER 2x PLATEOR (2)2x TOP PLWHEN TRUSS BOT.CHORD IS CAMBERED
2x BLK'G @ 24"o.c.w/(2)16d TO EACHMEMBER
SIMP. STC @EACH CONNECT(MAX. @ 24"o.c.)
2x BLK'G @ 24"o.c.w/(2)16d TO EACHMEMBER2x MEMBER w/(2)16d TO BLK'G Ix OVER 2x PLATE
OR (2)2x TOP PLWHEN TRUSS BOT.CHORD IS CAMBERED
BOT. CHORDOF TRUSS
(2)2x TOP PL
TYPICALEDGE NAILING
2x8 BRACING(2)16d @ 12"o.c.
2x CEILING JOISTOR BOTTOMCHORD OF TRUSS
Ix OVER2x PL OR(2)2x TOP PLWHEN TRUSSBOT. CHORDIS CAMBERED
BOT. CHORDOF TRUSS
2x BLK'G.x12" LONG@ ±6'-0"o.c.NAILED TOTOP PLATEw/(3)16d.
2x BLK'G@ 24"o.c.w/(2)16dTO EACHMEMBER
FRAMING TO NON-BEARING WALLS
3
7
MAX. 8'-0"
CODE APPROVED "SHOT PINS",SEE FOUNDATION PLAN NOTES
MUD SILL W/ ANCHOR BOLTSSEE FOUNDATION PLAN FORSIZE & SPACING
SOLID RIM JOIST PER PLANMIN. 2X4 STUDS @ 16"o.c. AT INTERIORBEARING, AND EXTERIOR SHEAR WALLS.(MAX. HEIGHT=10') U.N.O.MIN. 2X4 STUDS @ 24"o.c. AT INTERIORNON-BEARING AND NON-SHEAR WALLS.(MAX. HEIGHT=14')
PROVIDE SOLID BLOCKINGOR CONT. RIM JOIST ATALL BEARING POINTS
BLK'G. (2x, I-JOIST) MIN. 12" LONG@ MAX. 48"o.c. WITH FLOOR E.N.SECURE w/(2)16d E/S.
2x SHAPED BLKG. (SEE 13/GD FOR ALT.)w/ 16d @ 6"o.c. @ SHEAR TRUSSNOTE: A35 @ 24"o.c., CAN BE USED TOCONNECT BLKG. TO TRUSS IN LIEU OFNAILING
2X PRESSURE BLK'G. @ EVERY OTHERTRUSS w/(6)16d TO GIRDER TRUSS &(3)16d END NAIL TO EACH TRUSS.
(3) 16d's
1x4 CANT. LATERALBRACE @ 48"o.c.(1) A35 @ BRACE
TO TRUSS
E.N.ROOFSHEATHING
TYPICAL FRAMING CROSS SECTION
NOTES:1. FOR PARALLEL CONDITION, BLK'G. MAY BE OMITTED IF A SINGLE JOIST IS ALIGNED UNDER A WALL WHICH SPANS UNDER 1/2 THE LENGTH OF THE JOIST: OR A DBL. JOIST IS ALIGNED UNDER A WALL WHICH SPANS OVER 1/2 THE LENGTH OF THE JOISTS.2. "I"-JOIST BLK'G. MAY BE USED WHEN I-JOIST SYSTEM IS USED. USE FILLER AS REQUIRED.3. FOR PARTITION LENGTH LESS THAN 8'-0" NO BLK'G. IS REQUIRED.4. OFFSET JOIST(S) @ PLUMBING WALL & USE LADDER BLK'G. @ 24" O.C.
PERPENDICULARCONDITION
ALT. SIMP."Z" CLIP.
PARALLELCONDITION
ALTERNATECONDITION
BEARING & NON-BEARING WALL
EXTERIOR FIREPLACE CONN.
1/2" THICKPLYWOOD SHT'G. ROOF SYSTEM
1/2" THICK PLYWOODSHT'G w/ NAIL @ 6"o.c.TO LEDGER/TOP PL.
1/2" THICK PLYWOODON 3 SIDES @ JOINT& EXTEND 4'-0" E.W.
2x LEDGERw/ 16d @ 6"o.c.& LTP4 @ 8"o.c.TO DBL. TOP PL.
PLYWOOD FLOORSHT'G. CONT.THRU FIREPLACE
PLYWOOD SHIMAS REQ'D w/ 16dSINKER F.N. @ 4"o.c.DBL. T.P. FOR LTP4
FIREPLACE FLUE
CUT HOLE INPLYWOOD ONLYAS REQUIRED
FLOOR SYSTEM
NOTE:FULLY NAIL CS16 w/ 10d SINKER NAILS.
CHIMNEY STACKON ROOF
SIMPSON CS16 STRAPw/ 16" MIN. LAP ON CORN.STUDS & CONT. A35CLIP AT BOT. TRUSS
SIMPSON LTP4 EA. SIDETO BOT. CHORDOF TRUSS
PROVIDE SOLID VERT.BLOCKS UNDER CORN.OF CHIMNEY BETW.TRUSS CHORDSw/ ROOF TRUSSES
SLOT CUT ROOFSHT'G AT STRAPS
CHIMNEY STACKON ROOF
CS16 EA. CORN.w/ MIN. 16" LAP ONCORN. STUD &FILLER BLOCKBELOW AT CONDITION
ADD VERT. 2x FILLERBLOCK w/ E.N. TORECEIVE STRAPS
ADD SHEAR PANELBLK'S w/ 1/2"SHT'G & 10d @4"o.c. ALL AROUND
(2)A35 EA. SIDEOF PANEL BLK'STO TRUSS
INTERIOR CHIMNEY TIE DOWN
NOTE: BORED HOLES NOT PERMITTED IN MORE THAN TWO CONSECUTIVE DOUBLE STUDS.
NOTCH DEPTH
STUD SIZE EXT. & BRN'G.WALLS
NON-BRN'G.WALLS
2x42x6
7/8"1 3/8"
1 7/16"2 3/16"
BORED HOLES
STUD SIZE EXT. & BRN'G.WALLS
NON-BRN'G.WALLS
2x42x6
1 3/8"2 3/16"
2 1/8"3 5/16"
2-2x4 2 1/8" 2 1/8"2-2x6 3 5/16" 3 5/16"
NOTCH DEPTH & BORED HOLESEE TABLE BELOW
SILL PLATE
STUD
STUD NOTCHING/BORING LIMITS
16"MIN.
48'MAX.
1/8"GAP
1/8"GAP
TYP. 2-BAYS OFBLKG. USE CS16OVER BLK'G ANDNAIL @ 2 1/16"o.c.U.N.O. ONFRAMING PLAN
TAIL JOIST/ TRUSSPER PLAN
OPENING INDIAPHRAGM
BLOCK OUT EDGES OFTHE OPENING w/ DBL.STRUCT'L. MEMBERS/ BEAM(U.N.O.) AND PROVIDE B.N. @ALL EDGES. PROVIDE SINGLEBLOCKING w/ E.N. WHEN OPENING< 24"x24", AND STRAPS PERNOTE 18 DO NOT APPLY
FRAMINGMEMBERS
TYP. APPROVEDHANGERS USE(3)16d TOE NAILSIF LENGTH OFTAIL JOIST < 6'-0"
24" MIN. UNLESSFULLY BLOCKED@ ALL EDGES
PANEL EDGE WHERE2x FLAT BLKG. ISNEEDED @ BLOCKEDDIAPHRAGM
DIRECTION OFFACE GRAINPERPENDICULARTO SUPPORT
24" MIN. UNLESSFULLY BLOCKED@ ALL EDGES
FIELD NAILINGPER PLAN
1/8" GAP U.N.O.
CONT. PANEL EDGEw/ BLKG. (IF BLOCKEDDIAPHRAGM), EDGENAILING PER PLAN
DISCONTINUOUSPANEL EDGE, EDGENAILING PER PLAN
DIAPHRAGMBOUNDARY &B.N. PER PLAN
OFFSET EDGESUPPORT
ALT. CONDITION
PANEL JOINT
2x4 w/ NAILSTO BE MATCHEDw/ EDGE NAILING
ROOF ORFLOORSHEATHING
ROOF OR FLOORFRAMING MEMBER2x4 BLK'G 6'-0"LONG MAX w/(2)16d COMMONNAILS @ EA. END
NOTES:1) STAGGERED JOINTS AS SHOWN2) NAILS SHALL BE DRIVEN TIGHT BUT SHALL NOT FRACTURE SURFACE OF SHEATHING.3) SEE GENERAL NOTES FOR PLYWOOD TYPE, THICKNESS, SPACING, & NAIL SIZE.4) PROVIDE MIN. 3/8" EDGE DISTANCE @ FRAMING MEMBER & 5/16" TO EDGE OF PLYWOOD DIAPHRAGM.5) ALL DIAPHRAGM BOUNDARIES SHOULD BE FULLY SUPPORTED BY FRAMING MEMBERS w/ BOUNDARY NAILING6) T&G EDGE TO BE LOCATED OVER CONTINUOUS PANEL JOINT.7) MAX. UNSUPPORTED SHEATHING TO BE 24". PROVIDE ADEQUATE FRAMING MEMBERS TO LIMIT SPAN.
SHEATHING LAYOUT
NAILS2 1/16"
CS16 DRAG STRAP NAILING PATTERN
1
1A
2
3
4
5
8
7
6912
10
11PIPING THRU PLATE FRAM'G-NON SW
PIPE WHERE OCCURS
1 3/4" MAX IF IN 2x4TOP TOP PL.STRAPEA. SIDE OF PL.w/ #3 BELOW PL.OR 2 3/4" IN 2x6
SIMPSON RPS METALSTRAP TYPICAL AT EA. PL.CUT w/(6)16d @ EA. SIDEU.N.O. ON PLANSPER DETAIL 9/SD-2
PIPE WHEREOCCURS
TOP PLATES/ SILL PLATES
NOTCHIN PLATE
TOP PLATES/ SILL PLATES
ANCHOR BOLTSPER PLAN
SIMPSON RPS METALSTRAP TYPICAL ATEA. PL. CUT w/(6)16d@ EA. SIDE U.N.O.ON PLANS PERDETAIL 9/SD-2
NOTES: 1. IF NOTCH OR HOLE EXCEEDS 50% OF TOP PLATE WIDTH, STRAP BOTH SIDES OF PLATES. 2. FOR PIPING THRU TOP & SILL PLATES OF SHEAR WALLS, CONTACT E.O.R.
NOTES:1) FOR OTHER HOLE SIZES & JOIST TYPE, SEE MANUFACTURER SPEC.2) DO NOT CUT HOLES LARGER THAN 1 1/2" IN CANTILEVER PORTION OF THE JOIST.3) A 1 1/2" HOLE CAN BE CUT ANYWHERE IN THE WEB. EXCEPT WITHIN 6" AWAY FROM SUPPORT.4) REFER TO MANUFACTURERS GUIDE-LINES IN I-JOIST CATALOG FOR MORE INFO.5) NO FIELD CUT WITHIN 6" AWAY FROM FACE OF SUPPORT.
NOTES:1) FOR SOLID SAWN JOISTS, NOTCHED TO BE @ OUTER 1/3 SPAN ONLY.2) MAINTAIN MIN. 6" SPACING BETWEEN NOTCHES/ BORED HOLES.
4" 8 7/8" 11"6 1/2"b
1'-0"1'-0"
2'-0"2'-0"
2'-6"3'-0"1'-6"2'-6"
5'-0"
4'-0"5'-6"
5'-6"
6'-6"7'-0"7'-0"8'-0"
5'-6"
5'-6"
6'-0"3'-6"
8'-0"9'-0"9'-6"
6'-6"
N.A. N.A.N.A.N.A.
* TYPICAL MIN. DISTANCE BTWN. HOLES TO BE 2X THE LARGER HOLE.
JOIST DEPTH.
1/6 OF JOISTDEPTH MAX.
1/3 OF JOISTSPAN MAX.
PIPE ORCONDUIT.
1/6 OF JOISTDEPTH MAX.1/3 OF JOIST
SPAN MAX.
1/4 OF JOISTDEPTH MAX.AT SUPPORT END.
JOIST DEPTH.
1/3 OF JOISTDEPTH MAX.
2" CLEAR TOEDGE OF JOIST.1/3 OF JOISTDEPTH MAX.
1/8"MIN.TYP.
*
**
a
b
NOTCH & HOLES IN I-JOIST
HOLE SIZEUP TO 3"TJI SIZE a
MIN. DIST. FROM EDGE OF HOLE TO EDGE OF SUPPORT11 7/8" 21011 7/8" 230
14" 23014" 360
1'-0"1'-0"1'-0"1'-0"
ba ba ba ba
1'-0"1'-0"1'-0"1'-0"
1'-0"1'-0"1'-0"1'-0"
NOTCH & HOLES IN CONV. JST.
12" MAX.5"
12" MAX.5"
3/8" MAX. NAILEXPOSURE @ GAP
2x BLK'G., LEDGER, R/ R.OR TRUSS TOP CHORDUNDER ROOF SHEATHINGWHEN NOT BEVELED ONTOP AS REQ'D
INCREASE NAILING TO8d @ 3"o.c. ONNON-BEVELED MEMBER
ROOFSHEATHING
3/8" MAX. NAILEXPOSURE @ GAP
2x BLK'G., LEDGER, R/ R.OR TRUSS TOP CHORDUNDER ROOF SHEATHINGWHEN NOT BEVELED ONTOP AS REQ'D
ROOFSHEATHING
INCREASE NAILINGTO 8d @ 3"o.c. ONNON-BEVELEDMEMBER
SHEAR TRANSFER
16"MIN.
48'MAX.
1/8"GAP
1/8"GAP
TYP. 2-BAYS OFBLKG. USE CS16OVER BLK'G ANDNAIL @ 2 1/16"o.c.U.N.O. ONFRAMING PLAN
TAIL JOIST/ TRUSSPER PLAN
OPENING INDIAPHRAGM
BLOCK OUT EDGES OFTHE OPENING w/ DBL.STRUCT'L. MEMBERS/ BEAM(U.N.O.) AND PROVIDE B.N. @ALL EDGES. PROVIDE SINGLEBLOCKING w/ E.N. WHEN OPENING< 24"x24", AND STRAPS PERNOTE 18 DO NOT APPLY
FRAMINGMEMBERS
TYP. APPROVEDHANGERS USE(3)16d TOE NAILSIF LENGTH OFTAIL JOIST < 6'-0"
24" MIN. UNLESSFULLY BLOCKED@ ALL EDGES
PANEL EDGE WHERE2x FLAT BLKG. ISNEEDED @ BLOCKEDDIAPHRAGM
DIRECTION OFFACE GRAINPERPENDICULARTO SUPPORT
24" MIN. UNLESSFULLY BLOCKED@ ALL EDGES
FIELD NAILINGPER PLAN
1/8" GAP U.N.O.
CONT. PANEL EDGEw/ BLKG. (IF BLOCKEDDIAPHRAGM), EDGENAILING PER PLAN
DISCONTINUOUSPANEL EDGE, EDGENAILING PER PLAN
DIAPHRAGMBOUNDARY &B.N. PER PLAN
OFFSET EDGESUPPORT
ALT. CONDITION
PANEL JOINT
2x4 w/ NAILSTO BE MATCHEDw/ EDGE NAILING
ROOF ORFLOORSHEATHING
ROOF OR FLOORFRAMING MEMBER2x4 BLK'G 6'-0"LONG MAX w/(2)16d COMMONNAILS @ EA. END
NOTES:1) STAGGERED JOINTS AS SHOWN2) NAILS SHALL BE DRIVEN TIGHT BUT SHALL NOT FRACTURE SURFACE OF SHEATHING.3) SEE GENERAL NOTES FOR PLYWOOD TYPE, THICKNESS, SPACING, & NAIL SIZE.4) PROVIDE MIN. 3/8" EDGE DISTANCE @ FRAMING MEMBER & 5/16" TO EDGE OF PLYWOOD DIAPHRAGM.5) ALL DIAPHRAGM BOUNDARIES SHOULD BE FULLY SUPPORTED BY FRAMING MEMBERS w/ BOUNDARY NAILING6) T&G EDGE TO BE LOCATED OVER CONTINUOUS PANEL JOINT.7) MAX. UNSUPPORTED SHEATHING TO BE 24". PROVIDE ADEQUATE FRAMING MEMBERS TO LIMIT SPAN.
SHEATHING LAYOUT
NAILS2 1/16"
CS16 DRAG STRAP NAILING PATTERN 17
13
16
GD
GENERAL
DETAILS & NOTES
H.M. A.D.
PROJECT NAME:
ARCHITECT:
DEVELOPER:
ADDRESS:
PLOT DATE:
DESIGNED BY:
SHEET NAME:
SHEET NUMBER:
PROJECT NUMBER:
DESCRIPTIONDATENO.
REVISIONS
aBPa
RMO Greenfield Estates
M&O Investments
EL CAJON, CA
INGAMAC WAY
50011
04/13/2015
CHECKED BY:
BLDG. DEPT.03/31/20151
WALL W/ PLUMB./ MECH
PLUMBING OR MECHANICALLINE IN WALL INTERRUPTINGPLATES AND RIM JOIST@ FLOOR LEVEL.SPLICE RIM W/ ST6224STRAP (U.N.O.) ON PLANS.
SPLICE PLATES @ FLR. LEVELW/ SIMPSON RPS STRAPSW/(6) 16d's @ EA. END OF EA.STRAP. ALT., USE 'ST' STRAPW/(6) 16d's @ EA. END,P/ PLATE. STRAP ONE SIDEONLY IF PLUMBING CAUSESNOTCH OF PLATE NO MORETHAN 50% OF PLATE WIDTH.
ROOF MEMBERS.EAVE BLK'G TO REMAIN.
ADD NEW FLAT 2x BLK'G MIN.(3) BAYS @ PIPE W/ (4) 10d'sPER BLK'G FROM FLOORSHT'G. AT BAY W/INTERRUPTED RIM JOIST,ADD ONE ADDITIONAL BLK'GEACH WAY.
SPLICE UPPER TOP PLATESW/ STRAP AS REQ. P/ DRAGDETAIL ON PLANS. STRAPBOTH SIDES W/ SAME STRAPWHEN CUT EXCEEDS 50% OFPLATE WIDTH. USE 16d SHORTNAILS (2 1/2" LONG).
PLUMBING OR MECHANICALLINE IN WALL INTERRUPTINGPLATES AND RIM JOIST@ FLOOR LEVEL.
FIELD FIX @ PLATE/RIM BREAK
X X
TYP. BLK'G OR RIM. ROOF OR FLOOR SHEATHING.
ROOF TRUSS OR TJI's@ SIMILAR CONDITION@ FLOOR.
TYP. BLK'G OR RIM.
DBL. TOP PLATES.
2x4 STUDS.2x4 STUDS.
(2) CS16 EA. SIDE W/ 10d's@ 2" O.C. MAX STRAPS TOBE NAILED @ TOP OF SHEARPANEL AND TO HAVE MIN.NO. OF NAILS EQUAL TOSPLICE NAILING PER PLAN.N 10 NAILS MAY BE USED.
X= LENGTH TO BE ENOUGH TO HAVE MIN. NO. OF NAILS OF SPLICE NAIL AS PER PLAN (STRAPS MUST EXTEND MIN. ONE STUD BAY EACH WAY).
RIM INTERRUPTED @ DUCT.
A35 PER PLAN AND MIN. (1)EA. SIDE OF BREAK.
(2) CS16 EA. SIDE W/ 10d's@ 2" O.C. MAX STRAPS TOBE NAILED @ TOP OF SHEARPANEL AND TO HAVE MIN.NO. OF NAILS EQUAL TOSPLICE NAILING PER PLAN.N 10 NAILS MAY BE USED.
CS STRAP @ EA. SIDE SOLEPLATE IF CUT.
ADD FULL HEIGHT BLK'G W/SHEATHING E.N. @ AFFECTEDBAY AND ONE BAY EA. WAYBEYOND. MIN. (3) BAYS OFBLOCKING.
(2) CS16 EA. SIDE W/ 10d's@ 2" O.C. MAX STRAPS TOBE NAILED @ TOP OF SHEARPANEL AND TO HAVE MIN.NO. OF NAILS EQUAL TOSPLICE NAILING PER PLAN.N 10 NAILS MAY BE USED.
SECTION @ FLOOR FRAMING
SECTION @ ROOF FRAMING
E.N.
A35, PER BLOCK.
ADD 2X6 MIN. BLK'G W/SHEATHING E.N. @ AFFECTEDBAY AND ONE BAY EA. WAYBEYOND. MIN. (3) BAYS OFBLOCKING.
SHEAR PANEL.
(2) CS16 EA. SIDE W/ 10d's@ 2" O.C. MAX STRAPS TOBE NAILED @ TOP OF SHEARPANEL AND TO HAVE MIN.NO. OF NAILS EQUAL TOSPLICE NAILING PER PLAN.N 10 NAILS MAY BE USED.
(2) CS16 EA. SIDE W/ 10d's@ 2" O.C. MAX STRAPS TOBE NAILED @ TOP OF SHEARPANEL AND TO HAVE MIN.NO. OF NAILS EQUAL TOSPLICE NAILING PER PLAN.N 10 NAILS MAY BE USED.
FIX FOR CUTS IN SLABS
NOTES FOR P.T. SLAB:- MARK-UP TENDON ROUTE IN BOTH DIRECTIONS ON SLAB SURFACE IN THE VICINITY OF THE PROPOSED OPENING PRIOR TO PROCEEDING WITH THE SLAB EXCAVATION.- DE-TENSION ALL TENDONS PASSING THRU THE AREA BEING CUT. IF CUTTING BETWEEN TENDONS, NO NEED TO DE-TENSION CABLES, BUT CUT MUST BE 6" AWAY FROM CABLE.
- EXTREME CARE SHALL BE TAKEN NOT TO DAMAGE ANY TENDON DURING REPAIR.- POUR NEW 4000 PSI CONCRETE TENDONS SHALL NOT BE RE-STRESSED UNTIL NEW CONC. REACHES 3000 PSI. (IN CASE TENDONS WERE DE-TENSIONED).- SPECIAL INSPECTION IS REQUIRED DURING CONSTRUCTION PROCESS.
PLAN VIEW
PROVIDE VAPOR BARRIERUNDER SLAB
OPENING IN CONC. SLAB.TYP. #4 DOWELS @ 12" O.C.(MIN. 2 PER SIDE) EMBEDDEDIN SLAB AS SHOWN W/ EPOXYGROUT MIX. USE DOWELS TOP& BOTTOM @ 8" OR THICKERSLAB. PLACE DOWELSAPPROXIMATELY 1 3/4" FROMTOP OF SLAB.
WIDTH OF OPENING MUST BEMIN. 20" TO ALLOW FORDOWELING AS SHOWN.
1 GF
GENERAL
DETAILS & NOTES
H.M. A.D.
ADDITION OF FTN'G./SLAB AT EXISTING FOUNDATION
EXISTING FOUNDATION
MIN. 5" EMBEDMENT OFDOWELS INTO EXISTINGCONCRETE W/ SIMPSON SET-XPEPOXY, ESR #2508. PERIODICSPECIAL INSPECTION IS REQ'D.
FOOTING REINFORCEMENTPER PLAN OR MIN. (1) #4 TOPAND (1) #4 BOTTOM.
NEW FOOTING, MINIMUM SAMESIZE AS EXISTING OR SEEPLAN FOR SIZE.
NEW FOOTING, MINIMUM SAMESIZE AS EXISTING OR SEEPLAN FOR SIZE.
NEW FOOTING, MINIMUM SAMESIZE AS EXISTING OR SEEPLAN FOR SIZE.
ADDITIONAL #4 BOTTOM DOWELAT ENDS ONLY.
EXISTING FOUNDATION
MIN. 5" EMBEDMENT OFDOWELS INTO EXISTINGCONCRETE W/ SIMPSON SET-XPEPOXY, ESR #2508. PERIODICSPECIAL INSPECTION IS REQ'D.
NEW SLAB PER PLAN
1 1/2"
AREA OF FRAMINGTO BE "CUT-OUT"
1/8" MIN., TYP.
FIX AND ALTERNATE @ ADJOININGPANEL EDGES OF SHEAR WALLS
EDGE NAILING @ ADJOININGPANEL EDGES, TYP.
AS BUILT.(NOT ACCEPTABLESEE FIX BELOW)
SHEAR PER PLANS, TYP.3X MIN. POST (PER SW SCHED.)MIS-INSTALLED W/ A 2X STUD.
SHEAR PANELWHERE OCCURSTHIS SIDE ALSO,PER PLAN TYP.
EDGE NAILING @ ADJOININGPANEL EDGES, TYP.
SHEAR PERPLANS, TYP.NEW POST AS SHOWN.
POST TO BE SIZED TOACHIEVE MIN. 1 1/2"OVERLAP OF SHEAR PANEL.
SHEAR PANEL WHERE OCCURSTHIS SIDE ALSO, PER PLAN TYP.
FIELD FIX.
EDGE NAILING @ ADJOININGPANEL EDGES, TYP.
SHEAR PER PLANS, TYP.
SHEAR PANEL WHERE OCCURSTHIS SIDE ALSO, PER PLAN TYP.
ALTERNATE TO 3X MIN. POST PERSW SCHEDULE, USE (2) 2X STUDSW/ 2 ROWS OF 16d SINKER NAILS(ROWS STAGGERED) WITHSPACING IN EACH ROW PERSCHEDULE BELOW.
PANEL TYPES NAIL SPACING
@ 12" O.C.
@ 9" O.C.
@ 6" O.C.
@ 5" O.C.
@ 4" O.C.
@ 3" O.C.
@ 2 1/2" O.C.
2
3
4
5
3
4
5
DBL SIDED
DBL SIDED
DBL SIDED
2
FIELD FIX-MISPLACED NAILING
1/8"
1/8"
EXIST. 2X, 3X PER PLANS.
NEW 2X BOTH SIDES.
EDGE NAILS TONEW 2X PERS.W. SCHEDULE.
10d FACE NAILS @ 6" O.C.STAGG. ALONG STUD FACE.
2X STUD @PANEL JOINT
1/2" MIN.TYP.
3X STUD @PANEL JOINT
EXIST. 2X, 3X PER PLANS.
NEW 2X BOTH SIDES.
EDGE NAILS TO NEW2X MEMBER @ 2XREQUIRED SPACING(HALF NUMBERS OFNAILS REQ'D.) PERS.W. SCHEDULE.
1/4"Φ x 3 1/2" SDSSCREW FROMNEW 2X TO EXIST. 3X @ 10"O.C. FOR SINGLE SIDED S.W. & @5" O.C. FOR DOUBLE SIDED S.W.STAGG. ALONG STUD FACE.
1/2" MIN.TYP.
10d @ 6" O.C. STAGG. TO (E) 2X SILL PL.PER S.W. SCHED. USE 1/4"Øx3 1/2" SDSSCREWS TO (E) 3X MIN. SILL PLATE PERS.W. SCHED. @ 10" O.C. FOR SINGLESIDED S.W. & @ 5" O.C. FOR DOUBLESIDED S.W. STAGGERED FASTENERSALONG NEW 2X BLOCKING.
EXIST. 2X, 3X PER PLANS.2X BLOCKING.
NOTCH NEW 2X BLOCKINGWHERE ANCHOR BOLT OCCURS.
EDGE NAILS TO NEW2X MEMBER @ 2XREQUIRED SPACING(HALF NUMBERS OFNAILS REQ'D.) PERS.W. SCHEDULE.
SILL PLATE NAILING
MISPLACED HOLDOWN ANCHOR
RAISE HOLDOWN BRACKETHIGH ON WALL TO RECEIVEEXTENSION ROD.
USE APPROVED COUPLERAND EXTEND ROD W/ SLIGHTANGLE TO CENTER ROD INWALL. USE 12:1 RATIO(12" HIGH FOR 1" OFFSET).
EXISTING ANCHORMISPLACED.
EXISTINGMORE THAN1 3/4 " MIN
NOTE:THIS FIX SHALL NOT BE USEDIF ANCHOR IS MISPLACEDTOWARD OUTSIDE EDGE OFCONC. DUE TO MIN. EDGEDISTANCE REQUIREMENTS.
3
4
FIELD FIX FOR OPENING IN S.W.
1'-4"
OPENINGS OF MAX. 4 1/2"x4 1/2"DO NOT NEED BLK'G/STRAP.DO NOT CUT MORE THAN ONEOPENING IN ONE HORIZONTALLINE (AT ONE ELEVATION)AND OFFSET OPENINGS BYMIN. 4" VERT.SEE DETAIL 1/GD FOR OPENINGSSMALLER THAN 4 1/2" x 4 1/2"
SIMP. CS16X48" LONG W/NAILS @ 2 1/16" O.C.
ALT. LOCATION OF OPENINGIF CONT. SILL PLATE, NO "CS"STRAP REQUIRED @ BOTTOM.
NO CUT OR HOLESIN SHT'G WITHIN16" OF CORNERS.
NOTE:
- AVOID OPENING IN SHEAR WALLS W/ LENGTH LESS THAN 4'-0".- MAX. WIDTH OF OPENING TO BE ONE STUD BAY OR 14 1/2".- DO NOT OVER-CUT ANY FRAMING MEMBER.- E.N. TO BLK'G. TO MATCH SHEAR WALL E.N. UNLESS STRAP IS PLACED ON TOP OF PLYWOOD.- EDGE NAIL F.HT. ALONG STUD ON EACH SIDE OF OPENING.- IF OPENING IS LOCATED AT THE EDGE, EXTEND STRAP INTO THE SHEAR WALL TO MEET MIN. LENGTH REQUIRED.
5
6
7
8
TIE DWN. AT OFFSET POSTS
12"MAX
NOTE: FOR JOISTS PARALLEL TO WALL CONDITIONS ONLY
STUDS (OR POST) & CS16STRAPS FROM SHEAR PANELAT UPPER FLR. TO BE NAILEDTO SIDE OF RIM JOIST INFLOOR SYSTEM. SEE PLANSFOR NO. OF CS16's REQ.
ADD SOLID BLK. BEHIND RIM& CONT. 8" PAST STRAPSEA. WAY. NAIL W/(2) ROWSOF 16d's @ 4" O.C.
SAME NO. OF CS16 STRAPSAPPLIES FROM RIM TOPOST AT LOWER FLOOR.
ADD SOLID BLK. BEHIND RIM& CONT. 8" PAST STRAPSEA. WAY. NAIL W/(2) ROWSOF 16d's @ 4" O.C.
3"CLR.
48"
RETROFIT FOR MISSING FOOTING@ PREFABRICATED SHEAR PANEL.
TYP. EXISTING FOOTING.
PREFABRICATED SHEARPANEL PER PLAN
EXISTING CURB WHEREOCCURS..
DRILL HOLES IN EXISTINGCURB & FOOTING FOR NEWBOLTS. FILL HOLES W/ SIMP.SET EPOXY PRIOR TO BOLTPLACEMENT.
NEW 15" WIDE x 48" LONGGRADE BM. CENTERED @CORRECTLY PLACED PANEL.WHEN FTG. IS MISSING.
(2) NEW #5 BARS TOP & BOTT.
NATURAL GRADE.
TYP. 1 1/8"Ø OR 7/8"ØTHREADED RODS @PREFABRICATED SHEARPANEL PER PLAN
@ PLACES WHERE HTT22 HOLDOWN FIX CANNOT BE APPLIEDFIX FOR MISSING HOLDOWN
2 1/16" WIDE x 12GA. STRAP(MST48 OR EQUAL).
1/2" Φ SIMPSON TITEN HDCONCRETE SCREW ANCHORS.ICC-ESR# 2713 WITH 4 1/4"EMBEDMENT. REFER TO ICCAND MANUFACTURER SPECS.FOR INSTALLATIONPROCEDURES (SEE TABLE).
16d COMMON NAILSUSE 0.162Øx 2 1/2" NAILS.(SEE TABLE).
USE 4x4 POST MIN.
REPAIR CONC. SPALLING,IF OCCURS, W/ HIGH STRENGTHCONC. MIX.
MIN. (2) #4 DOWELS EMBEDED4 1/2" IN CONC.
9
10
11
HEAD OUT DETAIL
TYPICAL FLOOR SHEATHING.
SINGLE I--JOIST HEAD OUT"BEYOND".
SIMPSON "IUS" HANGER.
ADJACENT I-JOIST PER PLAN.
I-JOIST/250 BLOCK ALT.SOLID LSL BLOCK @ HEADOUT. WEB FILLER REQ'D. @I-JOIST OPTION.
ADJACENT I-JOIST PER PLAN.
WEB FILLER @ EA. SIDE OFI-JOIST @ EA. HANGERLOCATION, PERMANUFACTURER'SSPECIFICATIONS.
NOTE: FOR SINGLE I-JOIST HEAD OUT @ OUTER 1/3 SPANS ONLY.
STEM WALL ADDITION ONEXISTING SLAB
2X STUD WALL PER PLAN.
MIN. 3 1/2" WIDE X MAX. 12"TALL CURB TO BE ADDED.(f'c=2500 psi) MIN.
EXTEND EXISTING A.B. W/COUPLER NUT & 5/8"Φ RODS(f'c=2500 psi) MIN.
EXISTING 5/8"Ø X12" A.B.SPACED PER PLAN.
EXISTING SLAB & FOOTING.
USE (1) CONT. #3 BAR.
4"
8TYP
6"TO8"
FIX FOR WALL OVERHANGINGOFF FOUNDATION EDGE FOR
1 & 2 STORY COND. ONLY
NOTES:- ALL METALS EXPOSED TO WEATHER MUST BE PROTECTED AGAINST CORROSION.
- ANGLE TO BE CONTINUOUS.
- CONTACT E.O.R. FOR ALTERNATIVE FIX FOR THE FOLLOWING CONDITION: OVERHANG < 1 1/2" OR > 3 1/2".
EXISTING NON-SHEAR WALLOVERHANGING COMPLETELY ORPARTIALLY OFF FOUNDATIONEDGE , MIN 1 1/2" & MAX. 3 1/2".1" MIN
1/2" Φ WELDED STUD BOLTS @ 16" O.C.
3/8" THICK ANGLE IRON TOSUPPORT EDGE OF WALL.HORIZONTAL LEG TO MATCHOVERHANGING WALL (HORIZ.LEG MIN. 2"); VERTICAL LEGMIN. 6".1/2"Φ SIMPSON TITEN HD CONC.SCREW ANCHORS @ 8" O.C.W/ MIN. 6" FROM CONCRETEFOUNDATION EDGE.(ICC-ESR-#2713, SEPT. 2010)EXISTING
FOUNDATIONWALL.
A
A
EXISTING NON-SHEAR WALLOVERHANGING COMPLETELY ORPARTIALLY OFF FOUNDATIONEDGE , MIN 1 1/2" & MAX. 3 1/2".
1" MINA
A
3/8" THICK ANGLE IRON TOSUPPORT EDGE OF WALL.HORIZONTAL LEG TO MATCHOVERHANGING WALL (HORIZ.LEG MIN. 2"); VERTICAL LEGMIN. 6".1/2"Φ SIMPSON TITEN HD CONC.SCREW ANCHORS @ 8" O.C.W/ MIN. 6" FROM CONCRETEFOUNDATION EDGE.(ICC-ESR-#2713, SEPT. 2010)
EXISTING FOUNDATION WALL.
1/2" Φ WELDED STUDBOLTS @ 16" O.C.
CONC FOUNDATION EDGE.
SECTION A-A
FIX FOR OVERSIZED HOLEFIX USING EPOXY GROUT FIX USING SIMP. BPS 5/8
OVERSIZED HOLE OR HOLEGREATER THAN 1/16" OVERBOLT DIAMETER SIMPSON BPS 5/8
OVERSIZED HOLE OR HOLEGREATER THAN 1/16" OVER
BOLT DIAMETER
ANCHOR BOLT W/ WASHER.
SILL PLATE
EPOXY GROUT
STUD WALL PER PLAN
MISSING/MISPLACED COL. BASE
1 3/4"MIN.
POST PER PLAN.
SIMPSON ABU COLUMN BASETO MATCH POST SIZE.
5/8" DIA. SIMPSON WEDGE ALLANCHOR W/ 4 1/2" MIN.EMBEDMENT INTO CONCRETE@ MIDDLE OF SLAB CONDITION.
5/8" DIA. THREADEDROD EMBEDDED 5"INTO CONCRETEW/ SIMPSON SETEPOXY.
EDGE OF SLAB CONDITION MIDDLE OF SLAB CONDITION
NOTES:
- FOLLOW MFR. SPECIFICATIONS FOR INSTALLATION OF ABU AND ANCHORAGE SYSTEM
- PAD FOOTING BELOW SHOULD BE NO MORE THAN ± 8" OFFSET FROM POST LOCATION
12
13
14
15
16
CONCRETE SPALLING
REPLACE CONCRETESPALLING WITH HIGHSTRENGTH CONCRETEMIX, OR EPOXY(f'c=2500 PSI MIN.).
#4 DOWELS EMBEDED4 1/2" INTO EXISTINGCONCRETE @ 6" O.C. (MIN. 2).
FIX FOR MISSING HOLDOWN
MISSINGHOLDOWN
REPLACEWITH
EXT./INT. FTG.
HDU2, PA28
HPA28, HTT5, HPA35STHD10, STHD14
HDU2
5/8" TO
ALT. INT. FTG. W/SIMPSON EPOXY
ASTM-A36ROD Ø
3"x3"x3/8"
A36 PLATEWASHER
ASTMA307-C
1/2"ROD Ø
AA
hef
10" 8"
le
15" 12"5/8"HTT5
3 1/2"x3 1/2"x3/8" 16"1"
HDU11
HDU14 4"x4"x3/8"
HDU11
HDU14
6"MIN.
6"MIN.
19"
HDQ8HDQ87/8"
3 1/4"x3 1/4"x3/8"
2"x2"x1/4"
13"
12"HTT4
2 1/2"x2 1/2"x1/4"
C(MIN.)
HDU8HDU8
HDU4HDU4
HTT4 3/4" TO FTG.
HOLDDOWNSEE DET. B
DETAIL B
RAISE HOLDOWNBOTTOM FROM SILLPLATE.
CONC. EDGEWHERE OCCURS
NEW HOLDOWN,PER TABLE.
SIMPSONCNW 3/4-5/8COUPLER.
NEW HOLDOWN, PER TABLE.
THREADED ROD (THRUBOLT) W/ HEAVY HEXNUT TACK WELDED TOPLATE WASHER. SEESCHEDULE FOR PLATESIZE. ALT. TO TACKWELDING APPLYDOUBLE HEX NUTS TOSECURE PLATEWASHER.
NOTCH CONC. ALONG FTG. LENGTH TO 6"MAX. EA. SIDE OF HOLDOWN/ ROD. DO NOTCUT FTG. HORIZ. REINF. SOLID GROUT,WITHOUT ANY VOID, WITH HIGH STRENGTHNON-SHRINK GROUT W/ f'c=5000 psi MIN. CONT.SPECIAL INSPECTION IS REQUIRED.
THREADED ROD (THRU BOLT) W/ HEAVY HEXNUT TACK WELDED TO PLATE WASHER. SEESCHEDULE FOR PLATE SIZE. ALT. TO TACKWELDING APPLY DOUBLE HEX NUTS TOSECURE PLATE WASHER.
2 1/2" THK. MIN. DRY PACKED NON-SHRINKGROUT ALL AROUND. SURFACE IN CONTACTWITH GROUT SHALL BE CLEANED, FREE OFGREASE AND LAITANCE.
PROVIDE MIN. 3" CONC./NON-SHRINK GROUTCOVER ALL AROUND FOR ALL METAL PARTS.
6" MIN. FOR 1/2"Ø ROD.7" MIN. FOR 3/4"Ø ROD.
SEE GENERAL NOTES UNDER"REINFORCED CONCRETE"FOR ADD'L. REQUIREMENTS
THREADED ROD INSIMPSON EPOXYTO FOOTING PERTABLE.
THREADED ROD (THRU BOLT) W/HEAVY HEX NUT TACK WELDED TOPLATE WASHER. SEE SCHEDULEFOR PLATE SIZE. ALT. TO TACKWELDING APPLY DOUBLE HEXNUTS TO SECURE PLATE WASHER.
NOTCH CONC. ALONG FTG. LENGTH TO 6"MAX. EA. SIDE OF HOLDOWN/ ROD. DO NOTCUT FTG. HORIZ. REINF. SOLID GROUT,WITHOUT ANY VOID, WITH HIGH STRENGTHNON-SHRINK GROUT W/ f'c=5000 psi MIN.CONT. SPECIAL INSPECTION IS REQUIRED.
2 1/2" THK. MIN. DRY PACKED NON-SHRINKGROUT ALL AROUND. SURFACE IN CONTACTWITH GROUT SHALL BE CLEANED, FREE OFGREASE AND LAITANCE.
MULTI-STUDOR POST PERPLAN
2 1/2" THK. MIN. DRY PACKED NON-SHRINKGROUT ALL AROUND. SURFACE IN CONTACTWITH GROUT SHALL BE CLEANED, FREE OFGREASE AND LAITANCE.
_ USE SIMPSON SET-XP EPOXY ADHESIVEANCHORS, ICC-ESR-#2508 and LA RR#25744REFER TO ICC AND MANUFACTURER's SPECS.FOR INSTALLATION PROCEDURES.
_ CONTINUOUS SPECIAL INSPECTION & JOB-SITEQUALITY ASSURANCE ARE REQUIRED PER SECTION4.4 & 4.5 OF ICC-ESR#2508 and LA RR#25744.
- CONCTRACTOR SHALL SPECIFY OVERALL LENGTH OF ANCHOR._ FOR CUTTING THE SLAB & TIE SLAB BACK
SEE DETAIL "FIX FOR CUTS IN SLABS"_ FOR OTHER HOLDOWNS NOT LISTED IN TABLE
&/OR OTHER COND. NOT INCLUDED HERE,CONTACT ENGINEERING FOR SPECIFIC FIX.
NOTES:
NEW HOLDOWN,PER TABLE.
REPLACEMENT ANCHORS FOR EACH MISSING ANCHOR BOLT
SIMPSON TITEN HDSCREW ANCHORS
1-POUR OR 2-POUR W/ DOWEL(ICC ESR#2713, LA RR#25741)
WALL TYPE QUANTITY & SIZE
N.A.
(1) 5/8"Ø
2X4 SILL/3X4 SILL2X6 SILL/3X6 SILL
2X & 3X SILL
EXT.
INT.
1-POUR & 2-POURN.A.
(2) 1/2"Ø
SIMPSON SET-XP-EPOXY ADHESIVEWITH A307 GRADE C ANCHORS
QUANTITY & SIZE1-POUR
QUANTITY & SIZE1-POUR & 2-POUR
1-POUR OR 2-POUR W/ DOWEL(ICC ESR#2508, LA RR#25744)
EMBED.4"
5 1/4"
BOLT SIZE1/2"Ø5/8"Ø
(2) 1/2"Ø
EMBED.
2", 2X4 WALL3 1/2", 2X6 WALL
POST-INSTALLEDANCHOR PER TABLE.SPACING BETWEENANCHORS AND MIN.DISTANCE FROM EXIST.A.B. TO BE 4".
EMBED.
PLATE WASHERPER FOUNDATIONNOTES ON GNSHEETS.
PLATE WASHER PERFOUNDATION NOTESON GN SHEETS.
POST-INSTALLEDANCHOR PER TABLE.SPACING BETWEENANCHORS AND MIN.DISTANCE FROM EXIST.A.B. TO BE 4".
DOWEL PER NOTES OF 1/SD1.
MISSING OR MISSPLACE AB.
_ LOCATE ANCHORS @ 12" MIN. FROM CONCEDGE PERPENDICULAR TO WALL.
_ FOR NON-SHEAR WALL, INSTALL (1) 1/2"Øx4"EMBEDMENT TITEN HD ANCHOR FOR EACHMISSING OR MISPLACED A.B.
_ PERIODIC SPECIAL INSPECTION ISREQUIRED FOR ANCHOR INSTALLATION.
_ IF MIN. SPACING AND EDGE DISTANCE CANNOT BE MET, CONTACT ENGINEERING FORSPECIFIC FIX.
NOTES:
FIX FOR MISSING 3x SILL PLATE
4"
EXIST. 2x MUDSILLUSED IN LIEU OF 3X.
NEW 3x SILL BLOCKINGS"TIGHT FIT" @ EACH BAY FORTHE LENGTH OF SHEAR WALL.
EXISTING A.B.'s PER PLAN.
EXISTING FOUNDATION.
(E) SHEAR WALL EDGE NAILS PERSHEAR WALL SCHEDULE.
(4) 10d NAILS @ 3" O.C. MAX. STAGGEREDON NEW 3x MUDSILL BLOCKINGS.
ON NEW 3x MUDSILL BLOCKINGS.SCREW ANCHORS FOR EVERY(2) ANCHOR BOLTS. PERIODICSPECIAL INSPECTION IS REQUIREDPER ICC ESR 2713.
(4) 1/4"Ø x 3 1/2" SDS SCREWSSTAGGERED ON NEW 3x SILLBLOCKING TO EXIST. 2x SILL PLATE.
MIN.TYP.
SHEAR PANEL PER PLAN.
17
18
19
20
PROJECT NAME:
ARCHITECT:
DEVELOPER:
ADDRESS:
PLOT DATE:
DESIGNED BY:
SHEET NAME:
SHEET NUMBER:
PROJECT NUMBER:
DESCRIPTIONDATENO.
REVISIONS
aBPa
RMO Greenfield Estates
M&O Investments
EL CAJON, CA
INGAMAC WAY
50011
04/13/2015
CHECKED BY:
BLDG. DEPT.03/31/20151
ST1
316'-0"
28'
-0"
ST1
ST1
28'-0"
ST1 ST1
33'
-8"
39'
-7"
3SD1
3SD1
4SD1
4SD1
1SD1
1SD1
2SD1
2SD1
1SD1
5SD1
5SD1
1SD1
1SD1
2SD1
2SD1
P4
P2
P2
P2
1SD1
5SD1
9SD1
9SD1
9SD1
9SD1
9SD1
9SD1
5SD1
TD1
PER ARCH'LSLOPE
PER ARCH'LSLOPE
TD1
4SD1
2SD1
P1P1
TYP.
P1
P1P1
P1
P1
6SD1
TYP.
TD1
TD1
TD1
NOTE FOR SLAB:
CONCRETE SLAB WITH #
REBARS @ 18" O/C EACH WAY.
5"
4
P1
14'-0"
TD1 ST1
14'-0"
ST1 TD1
14'-0"
TD1 TD1
14'
-0" ST1
ST1
14'
-0"
ST1
18'
-0"
ST1
ST1
TD2
P1P1
PAD SCHEDULE
SYMBOLS LEGEND
SDXX
FOUNDATION NOTES1. REFER TO GN & GD SHEETS FOR MORE INFORMATION.
SHEAR PANEL LENGTH AND NUMBER.REFER TO GN FOR PANEL TYPE, MIN. 2-2x4 @ EA. END.
DETAIL NUMBER DETAILSHEET NUMBER
HOLDOWN NUMBER
PAD NUMBER
REBAR
DROP IN SLAB (VERIFY PRIOR TO CONSTRUCTION)
FOOTING
HOLDOWN SCHEDULESIMPSON HOLDOWN NOTESSYM.
REFER TO DETAIL 19/SD1STHD10RJ
STHD14RJ
STHD10
STHD14
HDU8
HDQ8
HDU11
HDU14
HHDQ14
HTT5
HHDQ11
2. FOR SHEAR PANEL TYPES 3, 4 & 5 ON BOTH SIDES OF WALL, USE MIN. 3X6 SILL PLATES U.N.O.
REFER TO DETAIL 19/SD1
3. CONTRACTOR IS RESPONSIBLE FOR VERIFYING HARDY FRAMES MATCH TOP PLATE
HEIGHT & NOTIFY ENGINEER OF RECORD IF DIFFERENT THAN PLANS.
4. TOP OF ALL EXTERIOR FOOTING, GRADE BEAM FOOTING, PAD FOOTING, OR FLAG
POLE FOOTING TO BE MIN. 6" BELOW FINISH GRADE.
5. f'c=3000 psi FOR ALL GRADE BEAMS.
X
X'-X"X
ST1
ST2
ST3
ST4
TD1
TD2
TD3
TD4
TD5
TD6
TD7
6. FOR NON-SHEAR WALLS, MASA/MASAP MUDSILL ANCHORS CAN BE USED IN LIEU OF
ANCHOR BOLTS WITH END DISTANCE OF 4" MIN. PER ESR #2555.
X
USP HOLDOWN
STAD10
STAD14
STAD10RJ
STAD14RJ
PHD8
UPHD8
HTT22
UPHD11
UPHD14
---------
---------
2'-0" SQ. X 18" DEEP PAD W/ (3) #4 E.W.
2'-6" SQ. X 18" DEEP PAD W/ (4) #4 E.W.
3'-0" SQ. X 18" DEEP PAD W/ (4) #4 E.W.
PAD TYPESYM.
3'-6" SQ. X 18" DEEP PAD W/ (5) #4 E.W.
4'-0" SQ. X 18" DEEP PAD W/ (6) #4 E.W.
4'-6" SQ. X 18" DEEP PAD W/ (6) #4 E.W.
5'-0" SQ. X 18" DEEP PAD W/ (7) #5 E.W.
5'-6" SQ. X 18" DEEP PAD W/ (7) #5 E.W.
P1
P2
P3
P4
P5
P6
P7
P8
S-1.1
FOUNDATION PLAN
PLAN 1
H.M. A.D.
PROJECT NAME:
ARCHITECT:
DEVELOPER:
ADDRESS:
PLOT DATE:
DESIGNED BY:
SHEET NAME:
SHEET NUMBER:
PROJECT NUMBER:
DESCRIPTIONDATENO.
REVISIONS
aBPa
M&O Investments
EL CAJON, CA
INGAMAC WAY
50011
04/13/2015
CHECKED BY:
BLDG. DEPT.03/31/20151
11. ALL WOOD I-JOISTS SHALL BE IN COMPLIANCE WITH THE PROVISIONS OF APA PRI-400,EWS-Z725B (PERFORMANCE RATED I-JOIST STANDARD) OR ASTM D5055. QUALIFIED PRI-400,MANUFACTURED. SUBMIT SHOP DRAWING TO E.O.R. FOR REVIEW AND APPROVAL.
FRAMING NOTES
4. AT DOUBLE SIDED SHEAR WALLS, POST W/E.N. PER PLAN TO RECEIVE E.N. FROM BOTH SIDES.
FRAMING SCHEDULE
POST OR TRIMMER AS NOTED
SYMBOLS LEGEND
KEY NOTES
X
X
8. ALL BEAMS SHOWN ARE DROP (U.N.O.) ON PLANS.
5. WHEN MULTIPLE STUDS ARE USED INSTEAD OF A SINGLE POST, PLYWOOD SHEAR WALL TO BENAILED TO ALL STUDS RECEIVING HOLDOWNS.
10. USE USP " THF " HANGERS FOR CONNECTION OF I-JOISTS TO OTHER FRAMING MEMBERS(U.N.O.) AND " JUS " HANGERS FOR CONNECTION OF SOLID JOISTS.
6. APPLY SHEAR PRIOR TO FRAMING OF PERPENDICULAR WALLS. DO NOT BREAK SHEAR ATPERPENDICULAR WALL LOCATIONS UNLESS SPECIFICALLY DETAILED ON PLANS.
7. ALL VERTICAL PIPES THROUGH PLATES AND/OR SOLID RIM BEAMS MUST BE DRILLED CLEAN CUTW/ 1/16" TOLERANCE. DO NOT NOTCH OR CUT PLATES.
LINE OF 2X FLAT BLOCKING W/ EDGE NAIL. & CONTINUOUS CS16 STRAP OVER U.N.O. SEEPLAN FOR NUMBER OF BAYS.
DRAG STRUT W/E.N.. SEE PLANS/DETAILS FOR LENGTH. SUPPORT END W/ BLK'G
X
BLOCKED FLOOR DIAPHRAGM W/ 10d's @ 4" O.C. B.N., 6" O.C. E.N. & 12" O.C. FIELD.
BLOCKED ROOF DIAPHRAGM W/ 8d's @ 4" O.C. B.N., 6" O.C. E.N. & 12" O.C. FIELD.
PROVIDE SOLID BLOCKING
TRUSS HANGER BY TRUSS SUPPLIER
SHEAR TRUSS W/E.N. TRUSS TO TRANSFER 180 PLF MIN. (U.N.O.)
DRAG TRUSS W/E.N. TRUSS TO TRANSFER 1650# FORCE MIN. (U.N.O.)
CONTINUOUS FULL HT. BLKG. W/E.N. SEE PLANS FOR NUMBER OF BAYS ( U.N.O.)
(1) SIMPSON TS22 FLUSH BEAM TO DROP BEAM ( U.N.O.)
CONTINUOUS TIMBERSTRAND OR SPLICE PER PLAN.
13. USE 2X TRIMMER FOR HEADERS LESS THAN 6'-0" AND 2-2X FOR 6'-0" TO 10'-0" LONG SPAN INBEARING WALLS, U.N.O. ON THE PLAN. REQUIRED TRIMMER MUST BE APPLIED @ EACH END OFHEADER. SEE PLANS FOR HEADERS LARGER THAN 10'-0" LONG.
FLOOR TO FLOOR HOLDOWN PER SCHEDULE BELOW:
X
ALIGN STUD(S) / POST(S) WITH UPPER FLOOR STUD(S) / POST(S) AND PROVIDE SOLIDBLOCKING BETWEEN FLOOR ( PROVIDE E.N. WHEN POST IS LOCATED WITHIN S.W. )
CONTINUOUS LINE OF BLOCKING W/ EDGE NAILUNDER SHEAR WALL ABOVE W/ (1) CS16, U.N.O.
14. INTERIOR NON-BEARING WALLS MAY BE FRAMED WITH 2x STUDS AT 24" O.C., MAX.
DIRECTION OF ROOF MEMBER PER SCHEDULE,REFER TO HATCHED WALLS ON PLANS FOR INTERMEDIATE BR'GDIRECTION OF FLOOR MEMBER PER SCHEDULE,REFER TO HATCHED WALLS ON PLANS FOR INTERMEDIATE BR'G
DETAIL NUMBER DETAILSHEET NUMBER
KEY NOTE NUMBER
BEARING WALL
CALIFORNIA FRAMING
CONTINUOUS JOIST W/ E.N.
12. A 4x6 HEADER SHOULD BE USED AT ALL OPENINGS IN EXTERIOR & INTERIOR BEARING WALLSU.N.O. ON PLANS. ALL 4X4 TO 4X12 SIZES CAN BE SUBSTITUTED WITH A 2-2x TO MATCH THEDEPTH AND THE 2-2X SHALL BE PLACED ON END WITH 1/2" PLYWOOD SHIM BETWEEN. PROVIDE16d NAILS @ 16" O.C., STAGG., BOTH SIDES.
1A / SD-3
PERPLAN APPLY DETAIL
REFERENCE &
1B / SD-3
1C / SD-3
1D / SD-3
PERPLAN APPLY DETAIL
REFERENCE &
1E / SD-3
PERPLAN APPLY DETAIL
REFERENCE &
- -
- -
14" TJI 230 I-JOISTS @ 16" O.C.
14" TJI 230 I-JOISTS @ 19.2" O.C.
DESIGNED ROOF TRUSSES @ 24" O.C.
14" TJI 360 I-JOISTS @ 16" O.C.
J2
J3
T
J1
2 X 12 DECK JOISTS @ 12" O.C.
2 X 12 DECK JOISTS @ 16" O.C.
2 X 12 ROOF RAFTERS @ 16" O.C.
2 X 10 ROOF RAFTERS @ 16" O.C.
R2
R1
D1
D2
1F / SD-3
1G / SD-3
BXX
X'-X"X
A
B
C
D
E
F
G
H
JX X
X'-X"X
X
X
1
2
3
4
5
6
7
8
9
10
11
12
13
14
2. REFER TO DETAIL 3/GD FOR TYPICAL CONNECTION AT ALL INTERIOR NON-BEARING WALLS ATROOF LEVEL.
1 3/4" X 14" PSL FLUSH15
4X6
4X6
4X6
4X8
4X6 DR BM
4X6
6X6
4X6TRIM4X6
TRIM
4X4
4X8 4X4
TRIM
4X4TRIM
4X4
8 3/4"X16 1/2" GLB TOP FL BM4X8
4X4
4X8
4X4
TRIM
4X6
TRIM
TRIM
3 1/
2"X1
4" P
SL 2
.0E
FL B
M
4X6
3 1/2" X9 1/4" PSL 2.0E DR BM
4X4
4X4
4X4
5ASD2
5ASD2
6 3/4"X15" GLB TOP FL BM
4X4
4X4
4X4
4X4
2SD1
1SD2
1SD2
7SD3
7SD3
7SD3
3SD4
5ASD2
5ASD2
5BSD2
5BSD2
5BSD2
4X4
TRIM5B
SD2
4SD3
2ASD3
4SD3
7SD3
7SD3
12SD3
12SD3
12SD3
10SD2
12SD3
2SD4
1 3/4" X14" PSL 2.0E FL BM
HGUS
HGUS
2-2X
4W
/E.N
7SD3
12SD2
7SD3
4X8
HGUS
HGUSHGUS
12SD3
4X6
9DSD2
13SD2
3SD3
3SD3
3SD3
4X8 DR BM
4 BAYS
5ASD3
2ASD3
8X83
SD3
TRIM
5ASD2
2SD4
4SD4
4SD4
4SD4
4X6
6X6
6X6
4X64X6
17SD2
4X4
2X4W/E.N.
4X12
HDR
TRIM
5ASD2
1SD2
2SD2
2SD2
316'-0"
28'
-0"
28'-0"
33'
-8"
39'
-7"
14'-0"
14'-0"
14'-0"
4X4
4X4 4X4
14'
-0"
4X6
4X6
14'
-0"
4X6
MIN
6'-0
"RR
W/E
N
14ASD2
18'
-0"
4X4
4X4
4X4
9CSD2
S-1.2
FLOOR FRAMING PLAN
PLAN 1
H.M. A.D.
PROJECT NAME:
ARCHITECT:
DEVELOPER:
ADDRESS:
PLOT DATE:
DESIGNED BY:
SHEET NAME:
SHEET NUMBER:
PROJECT NUMBER:
DESCRIPTIONDATENO.
REVISIONS
aBPa
M&O Investments
EL CAJON, CA
INGAMAC WAY
50011
04/13/2015
CHECKED BY:
BLDG. DEPT.03/31/20151
ALTERNATE ELEVATION (U.N.O.)BASIC PLAN APPLIES TOALL INFORMATION FROM
4X8
4X6
CONT. 4X6
4X6
4X6
DRAG
GT-
B1 W
/E.N
2-2X4
2-2X6
B
15'-9"
B
4X6
18'
-0"
A
A
13'-9"
A
13'-9"
A
A
2SD2
1SD2
1SD2
7ASD2
7ASD2
1SD2
1SD2
2SD2
16'
-9"
A
A
212'-0"
B B
END TRUSS
12SD2
12SD2
2SD1
MIN
4 B
AYS
16ASD2
MIN
4 B
AYS
16ASD2
6SD2
2SD2
1SD2
1SD2
2SD2
1SD2
11SD2
3SD2
18'
-0"
A
A
18'
-0"
A
A
15SD2
S-1.3
ROOF FRAMING PLAN
PLAN 1
H.M. A.D.
PROJECT NAME:
ARCHITECT:
DEVELOPER:
ADDRESS:
PLOT DATE:
DESIGNED BY:
SHEET NAME:
SHEET NUMBER:
PROJECT NUMBER:
DESCRIPTIONDATENO.
REVISIONS
aBPa
M&O Investments
EL CAJON, CA
INGAMAC WAY
50011
04/13/2015
CHECKED BY:
BLDG. DEPT.03/31/20151
DW
MC
MC
A/C
1
7'-0"
ST1 ST1
1
4'-0"
ST1
2
6'-8"
TD1
1
3'-8"
ST1
3
5'-6
"
ST2
TD2
3
4'-9
"
TD2
TD2
3
4'-0
"
TD1
TD1
3
2'-9
"
ST2
TD2
1
12
'-0
"
ST1
ST1
2
3'-6"
TD1 TD1
2
3'-0"
TD1
TD1
TD1
2
4'-0"
TD2 TD2
1
8'-0"
TD1 TD1
1
8'-0
"
TD1
TD1
1
7'-1
0"
TD1
TD1
1
ARND
PLY.
3
2'-7
"
TD1
3
3'-1
0"
TD2
TD1
ST1
P1
P1
P1
P1
3
SD1
3
SD1
1
SD1
1
SD1
1
SD1
1
SD1
1
SD1
1
SD1
9
SD1
5
SD1
5
SD1
5
SD1
1
SD1
1
SD1
1
SD1
1
SD1
1
SD1
4
SD1
4
SD1
4
SD1
4
SD1
4
SD1
2
SD1
1
6'-9"
TD1 ST1
1
6'-9"
ST1
7
SD1
PER ARCH'L
SLOPE
PER ARCH'L
SLOPE
PER
ARCH.
PER
ARCH.
TD2
TD1
P1
P1
P3
P2
6
SD1
TYP.
ST2
NOTE FOR SLAB:
CONCRETE SLAB WITH #
REBARS @ 18" O/C EACH WAY.
5"
4
PAD SCHEDULE
SYMBOLS LEGEND
SDXX
FOUNDATION NOTES1. REFER TO GN & GD SHEETS FOR MORE INFORMATION.
SHEAR PANEL LENGTH AND NUMBER.REFER TO GN FOR PANEL TYPE, MIN. 2-2x4 @ EA. END.
DETAIL NUMBER DETAILSHEET NUMBER
HOLDOWN NUMBER
PAD NUMBER
REBAR
DROP IN SLAB (VERIFY PRIOR TO CONSTRUCTION)
FOOTING
HOLDOWN SCHEDULESIMPSON HOLDOWN NOTESSYM.
REFER TO DETAIL 19/SD1STHD10RJ
STHD14RJ
STHD10
STHD14
HDU8
HDQ8
HDU11
HDU14
HHDQ14
HTT5
HHDQ11
2. FOR SHEAR PANEL TYPES 3, 4 & 5 ON BOTH SIDES OF WALL, USE MIN. 3X6 SILL PLATES U.N.O.
REFER TO DETAIL 19/SD1
3. CONTRACTOR IS RESPONSIBLE FOR VERIFYING HARDY FRAMES MATCH TOP PLATE
HEIGHT & NOTIFY ENGINEER OF RECORD IF DIFFERENT THAN PLANS.
4. TOP OF ALL EXTERIOR FOOTING, GRADE BEAM FOOTING, PAD FOOTING, OR FLAG
POLE FOOTING TO BE MIN. 6" BELOW FINISH GRADE.
5. f'c=3000 psi FOR ALL GRADE BEAMS.
X
X'-X"X
ST1
ST2
ST3
ST4
TD1
TD2
TD3
TD4
TD5
TD6
TD7
6. FOR NON-SHEAR WALLS, MASA/MASAP MUDSILL ANCHORS CAN BE USED IN LIEU OF
ANCHOR BOLTS WITH END DISTANCE OF 4" MIN. PER ESR #2555.
X
USP HOLDOWN
STAD10
STAD14
STAD10RJ
STAD14RJ
PHD8
UPHD8
HTT22
UPHD11
UPHD14
---------
---------
2'-0" SQ. X 18" DEEP PAD W/ (3) #4 E.W.
2'-6" SQ. X 18" DEEP PAD W/ (4) #4 E.W.
3'-0" SQ. X 18" DEEP PAD W/ (4) #4 E.W.
PAD TYPESYM.
3'-6" SQ. X 18" DEEP PAD W/ (5) #4 E.W.
4'-0" SQ. X 18" DEEP PAD W/ (6) #4 E.W.
4'-6" SQ. X 18" DEEP PAD W/ (6) #4 E.W.
5'-0" SQ. X 18" DEEP PAD W/ (7) #5 E.W.
5'-6" SQ. X 18" DEEP PAD W/ (7) #5 E.W.
P1
P2
P3
P4
P5
P6
P7
P8
S-2.1
FOUNDATION PLAN
PLAN 2 - LOT 5
H.M. A.D.
PROJECT NAME:
ARCHITECT:
DEVELOPER:
ADDRESS:
PLOT DATE:
DESIGNED BY:
SHEET NAME:
SHEET NUMBER:
PROJECT NUMBER:
DESCRIPTIONDATENO.
REVISIONS
aBPa
RMO Greenfield Estates
EL CAJON, CA
INGAMAC WAY
50011
04/13/2015
CHECKED BY:
BLDG. DEPT.03/31/20151
DW
REF
1
8'-0
"
ST1
ST1
2
7'-0
"
ST1
ST2
4
4'-4"
TD2 TD4
2
12'-0"
TD1 TD1
1
6'-5"
TD1
2
8'-0
"
TD2
TD2
1
8'-0"
ST1 ST1
4
SD1
4
SD1
3
SD1
3
SD1
4
SD1
2
SD1
1
SD1
1
SD1
1
SD1
1
SDX
4
SD1
PER
ARCH.
P3
P2
P2
3
SD1
S-2.1A
PARTIAL FOUNDATION PLAN
PLAN 2 - LOT 6
H.M. A.D.
PROJECT NAME:
ARCHITECT:
DEVELOPER:
ADDRESS:
PLOT DATE:
DESIGNED BY:
SHEET NAME:
SHEET NUMBER:
PROJECT NUMBER:
DESCRIPTIONDATENO.
REVISIONS
aBPa
RMO Greenfield Estates
EL CAJON, CA
INGAMAC WAY
50011
04/13/2015
CHECKED BY:
BLDG. DEPT.03/31/20151
ALTERNATE ELEVATION (U.N.O.)
BASIC PLAN APPLIES TO
ALL INFORMATION FROM
DW
MC
MC
A/C
6x8 HDR
4x6
4x8
4x6
4x6
4x1
2 H
DR
4x6
4x1
0 D
R B
M
3 1/2"x14" PSL 2.0E FL BM
4x6
4x8
4x6
1 3/4"x14" PSL 2.0E FL BM
4x6
4x8 HDR
4x64x6
GT-B
G
T
-
B
G
T
-
B
2
-
2
x
4
G
T
-
B
G
T
-
B
5 1/4"x14" PSL 2.0E FL BM
8 3/4"x16 1/2" GLB 24F-V4 TOP FL BM
5 1
/4
"x1
4" P
SL
2
.0
E F
L B
M
2
-
2
x
4
3 1/2"x9 1/4" PSL 2.0E DR BM2
-
2
x
4
4
x
4
T
R
I
M
4
x
4
T
R
I
M
3 1
/2
"x1
1 7
/8
" P
SL
2
.0
E H
DR
2
-
2
x
4
T
R
I
M
2
-
2
x
4
T
R
I
M
1
7'-0"
4
x
4
4
x
4
3 1/2"x9 1/4" PSL 2.0E DR BM
1
4'-0"
4
x
4
T
R
I
M
2
6'-8"
4
x
4
4
x
4
4 BAYS
5A
SD3
4A
SD2
4 BAYS
5A
SD3
1
3'-8"
4
x
4
4
x
4
T
R
I
M
3 1/2"x9 1/4" PSL 2.0E DR BM
2
-
2
x
4
T
R
I
M
5A
SD2
5A
SD2
3
5'-6
"
4
x
4
4
x
4
T
R
I
M
3
4'-9
"
4
x
4
3
4'-0
"
4
x
4
4
x
4
3
2'-9
"
4
x
4
4
x
4
2
-
2
x
4
8A
SD2
8A
SD2
1
12
'-0
"
4
x
4
4
x
6
2
3'-6"
4
x
4
2
3'-0"
4
x
4
8A
SD2
8A
SD2
2
-
2
x
4
W
/
E
.
N
.
4
x
4
2
4'-0"
4
x
4
4
x
4
1
8'-0"
4
x
4
4
x
6
MIN 4 BAYS
5A
SD3
MIN 4 BAYS
5A
SD3
1
8'-0
"
4
x
4
4
x
8
MIN 4 BAYS
5A
SD3
12
SD3
1
SD2
1
SD2
1
SD2
7
SD3
7
SD3
7
SD3
1
7'-1
0"
4
x
4
2
x
4
W
/
E
.
N
.
5A
SD2
5A
SD2
4A
SD2
4A
SD2
7
SD3
1
SD2
1
SD2
2A
SD3
7
SD3
HGUS
MIT
1
ARND
PLY.
2-2x6 F.H. STUDS @ 16" O.C.
7
SD3
7
SD3
17
SD2
2A
SD3
2
-
2
x
4
3
SD3
3
SD3
12
SD3
12
SD3
12
SD3
5A
SD2
5A
SD2
14
SD3
14
SD3
14
SD3
3 1
/2
"x9
1
/4
"
PS
L 2
.0
E D
R B
M
2
-
2
x
4
T
R
I
M
2
-
2
x
4
T
R
I
M
5A
SD2
5A
SD2
2
-
2
x
4
T
R
I
M
3
2'-7
"
T
R
I
M
4
x
4
T
R
I
M
4
x
4
1
SD2
3
3'-1
0"
4
x
4
4
x
4
T
R
I
M
5A
SD2
5B
SD2
5A
SD2
5B
SD2
4
x
4
2
-
2
x
4
T
R
I
M
5A
SD2
5A
SD2
3 1
/2
"x1
1 7
/8
" P
SL
2
.0
E H
DR
8
SD3
4
x
8
4
SD3
4
SD3
7
SD3
7
SD3
7
SD3
4x1
0 H
DR
7
SD3
7
SD3
9B
SD2
1
6'-9"
4
x
4
4
x
4
1
6'-9"
4
x
4
4
x
4
CO
NT
.
CONT.
RR W/EN
14A
SD2
4A
SD2
CANT.
6A
SD3
3 BAYS
14
SD3
4
SD4
17
SD2
1 3/4"x14" PSL 2.0E FL BM
3 1/2"x11 1/4" PSL 2.0E DR BM
4
SD3
4
SD3
8A
SD2
8A
SD2
4
x
4
5A
SD2
1
1
1
1
1
4X
6
2A
SD3
11. ALL WOOD I-JOISTS SHALL BE IN COMPLIANCE WITH THE PROVISIONS OF APA PRI-400,EWS-Z725B (PERFORMANCE RATED I-JOIST STANDARD) OR ASTM D5055. QUALIFIED PRI-400,MANUFACTURED. SUBMIT SHOP DRAWING TO E.O.R. FOR REVIEW AND APPROVAL.
FRAMING NOTES
4. AT DOUBLE SIDED SHEAR WALLS, POST W/E.N. PER PLAN TO RECEIVE E.N. FROM BOTH SIDES.
FRAMING SCHEDULE
POST OR TRIMMER AS NOTED
SYMBOLS LEGEND
KEY NOTES
X
X
8. ALL BEAMS SHOWN ARE DROP (U.N.O.) ON PLANS.
5. WHEN MULTIPLE STUDS ARE USED INSTEAD OF A SINGLE POST, PLYWOOD SHEAR WALL TO BENAILED TO ALL STUDS RECEIVING HOLDOWNS.
10. USE USP " THF " HANGERS FOR CONNECTION OF I-JOISTS TO OTHER FRAMING MEMBERS(U.N.O.) AND " JUS " HANGERS FOR CONNECTION OF SOLID JOISTS.
6. APPLY SHEAR PRIOR TO FRAMING OF PERPENDICULAR WALLS. DO NOT BREAK SHEAR ATPERPENDICULAR WALL LOCATIONS UNLESS SPECIFICALLY DETAILED ON PLANS.
7. ALL VERTICAL PIPES THROUGH PLATES AND/OR SOLID RIM BEAMS MUST BE DRILLED CLEAN CUTW/ 1/16" TOLERANCE. DO NOT NOTCH OR CUT PLATES.
LINE OF 2X FLAT BLOCKING W/ EDGE NAIL. & CONTINUOUS CS16 STRAP OVER U.N.O. SEEPLAN FOR NUMBER OF BAYS.
DRAG STRUT W/E.N.. SEE PLANS/DETAILS FOR LENGTH. SUPPORT END W/ BLK'G
X
BLOCKED FLOOR DIAPHRAGM W/ 10d's @ 4" O.C. B.N., 6" O.C. E.N. & 12" O.C. FIELD.
BLOCKED ROOF DIAPHRAGM W/ 8d's @ 4" O.C. B.N., 6" O.C. E.N. & 12" O.C. FIELD.
PROVIDE SOLID BLOCKING
TRUSS HANGER BY TRUSS SUPPLIER
SHEAR TRUSS W/E.N. TRUSS TO TRANSFER 180 PLF MIN. (U.N.O.)
DRAG TRUSS W/E.N. TRUSS TO TRANSFER 1650# FORCE MIN. (U.N.O.)
CONTINUOUS FULL HT. BLKG. W/E.N. SEE PLANS FOR NUMBER OF BAYS ( U.N.O.)
(1) SIMPSON TS22 FLUSH BEAM TO DROP BEAM ( U.N.O.)
CONTINUOUS TIMBERSTRAND OR SPLICE PER PLAN.
13. USE 2X TRIMMER FOR HEADERS LESS THAN 6'-0" AND 2-2X FOR 6'-0" TO 10'-0" LONG SPAN INBEARING WALLS, U.N.O. ON THE PLAN. REQUIRED TRIMMER MUST BE APPLIED @ EACH END OFHEADER. SEE PLANS FOR HEADERS LARGER THAN 10'-0" LONG.
FLOOR TO FLOOR HOLDOWN PER SCHEDULE BELOW:
X
ALIGN STUD(S) / POST(S) WITH UPPER FLOOR STUD(S) / POST(S) AND PROVIDE SOLIDBLOCKING BETWEEN FLOOR ( PROVIDE E.N. WHEN POST IS LOCATED WITHIN S.W. )
CONTINUOUS LINE OF BLOCKING W/ EDGE NAILUNDER SHEAR WALL ABOVE W/ (1) CS16, U.N.O.
14. INTERIOR NON-BEARING WALLS MAY BE FRAMED WITH 2x STUDS AT 24" O.C., MAX.
DIRECTION OF ROOF MEMBER PER SCHEDULE,REFER TO HATCHED WALLS ON PLANS FOR INTERMEDIATE BR'GDIRECTION OF FLOOR MEMBER PER SCHEDULE,REFER TO HATCHED WALLS ON PLANS FOR INTERMEDIATE BR'G
DETAIL NUMBER DETAILSHEET NUMBER
KEY NOTE NUMBER
BEARING WALL
CALIFORNIA FRAMING
CONTINUOUS JOIST W/ E.N.
12. A 4x6 HEADER SHOULD BE USED AT ALL OPENINGS IN EXTERIOR & INTERIOR BEARING WALLSU.N.O. ON PLANS. ALL 4X4 TO 4X12 SIZES CAN BE SUBSTITUTED WITH A 2-2x TO MATCH THEDEPTH AND THE 2-2X SHALL BE PLACED ON END WITH 1/2" PLYWOOD SHIM BETWEEN. PROVIDE16d NAILS @ 16" O.C., STAGG., BOTH SIDES.
1A / SD-3
PERPLAN APPLY DETAIL
REFERENCE &
1B / SD-3
1C / SD-3
1D / SD-3
PERPLAN APPLY DETAIL
REFERENCE &
1E / SD-3
PERPLAN APPLY DETAIL
REFERENCE &
- -
- -
14" TJI 230 I-JOISTS @ 16" O.C.
14" TJI 230 I-JOISTS @ 19.2" O.C.
DESIGNED ROOF TRUSSES @ 24" O.C.
14" TJI 360 I-JOISTS @ 16" O.C.
J2
J3
T
J1
2 X 12 DECK JOISTS @ 12" O.C.
2 X 12 DECK JOISTS @ 16" O.C.
2 X 12 ROOF RAFTERS @ 16" O.C.
2 X 10 ROOF RAFTERS @ 16" O.C.
R2
R1
D1
D2
1F / SD-3
1G / SD-3
BXX
X'-X"X
A
B
C
D
E
F
G
H
JX X
X'-X"X
X
X
1
2
3
4
5
6
7
8
9
10
11
12
13
14
2. REFER TO DETAIL 3/GD FOR TYPICAL CONNECTION AT ALL INTERIOR NON-BEARING WALLS ATROOF LEVEL.
1 3/4" X 14" PSL FLUSH15
S-2.2
FLOOR FRAMING PLAN
PLAN 2 - LOT 5
H.M. A.D.
PROJECT NAME:
ARCHITECT:
DEVELOPER:
ADDRESS:
PLOT DATE:
DESIGNED BY:
SHEET NAME:
SHEET NUMBER:
PROJECT NUMBER:
DESCRIPTIONDATENO.
REVISIONS
aBPa
RMO Greenfield Estates
EL CAJON, CA
INGAMAC WAY
50011
04/13/2015
CHECKED BY:
BLDG. DEPT.03/31/20151
RAG
RAG
FAU INATTIC
6x8 HDR @ HI.
4x6
4x6
4x6
4x6
4x6
4x6 4x6
4x6
4x6
4x6
4x12 HDR
4x6
4x6
4x6
4x6
4x6
4x66x6
GT-B1
GT
-B
2
2
-
2
x
4
G
T
-
B
3
DRAG GT-B4 W/E.N.
DR
AG
G
T-B
5 W
/E
.N
.
2
-
2
x
4
2
-
2
x
4
DRAG GT-B6 W/E.N.
GT
-B
7
DRAG GT-B9 W/E.N.
G
T
-
B
8
2
-
2
x
4
2
-
2
x
6
1
12'-0"
A
A
1
5'-3"
A A
B
2
5'-6
"
A
1
8'-0
"
A
1
5'-6"
A A
2
-
2
x
4
2
-
2
x
4
3-P
OIN
T B
R'G
T
RU
SS
ES
2
-
2
x
4
T
R
I
M
2
-
2
x
4
T
R
I
M
5A
SD2
5A
SD2
2
-
2
x
4
T
R
I
M
2
-
2
x
4
T
R
I
M
5A
SD2
5A
SD2
1
SD2
2
SD2
1
SD2
1
SD2
13
SD2
6
SD2
11
SD2
TYP.
7A
SD2
2
SD2
1
SD2
1
SD2
1
SD2
2
SD2
1
SD2
1
SD2
1
SD2
11
SD2
7A
SD2
7A
SD2
11
SD2
TYP.
2
4'-0"
B
B
2
6'-8"
A B
17
SD2
MIN
6
'-0
"
RR
W
/E
N
14A
SD2
7A
SD2
OF
FS
ET
1
3'-7
"
B
1
3'-1
0"
B
2
-
2
x
4
15
SD2
1
6'-6
"
A
A
7A
SD2
1
4'-0
"
A
A
TYP.
7A
SD2
1
SD2
1
8'-0
"
A
A
2
2'-9
"
A
15
SD2
3 1/2"x9 1/4" PSL 2.0E DR BM
5
SD3
2
SD2
1
SD2
S-2.3
ROOF FRAMING PLAN
PLAN 2 - LOT 5
H.M. A.D.
PROJECT NAME:
ARCHITECT:
DEVELOPER:
ADDRESS:
PLOT DATE:
DESIGNED BY:
SHEET NAME:
SHEET NUMBER:
PROJECT NUMBER:
DESCRIPTIONDATENO.
REVISIONS
aBPa
RMO Greenfield Estates
EL CAJON, CA
INGAMAC WAY
50011
04/13/2015
CHECKED BY:
BLDG. DEPT.03/31/20151
DW
REF
4x12 HDR
G
T
-
B
1
1
G
T
-
B
1
3
4x6
G
T
-
B
1
4
4x6
4x6
1
8'-0
"
4
x
4
4
x
4
8 3
/4
"x1
6 1
/2
" G
LB
2
4F
-V
4 T
OP
F
L B
M
4
x
8
T
R
I
M
3 1/2"x14" PSL 2.0E FL BM
2
-
2
x
4
3 1
/2
"x1
4" P
SL
2
.0
E F
L B
M
2
7'-0
"
4
x
6
4
x
4
4
x
6
2A
SD3
2A
SD3
HGUS
4x6
6 3/4"x15" GLB 24F-V4 TOP FL BM
5 1
/4
"x1
4" P
SL
2
.0
E F
L B
M
HG
US
3 1/2"x14" PSL 2.0E FL BM
HGUS
HGUS
HGUS
2
-
2
x
4
T
R
I
M
2
-
2
x
4
T
R
I
M
5A
SD2
5A
SD2
5B
SD2
5 1/4"x14" PSL 2.0E HDR
1
SD2
4
4'-4"
4
x
4
4
x
6
T
R
I
M
5B
SD2
1
SD2
1
SD2
1
SD2
2
12'-0"
4
x
8
4
SD3
12
SD3
12
SD3
12
SD3
12
SD3
12
SD3
1
6'-5"
4
x
4
4B
SD2
7
SD3
7
SD3
2A
SD3
4
SD3
9B
SD2
2
8'-0
"
4
x
4
4
x
4
4A
SD2
4
x
4
2
x
4
W
/
E
.
N
.
1
8'-0"
4
X
4
4
X
4
7
SD3
7
SD3
2A
SD3
2
SD2
4
SD4
4
SD4
4
SD4
G
T
-
B
G
T
-
B
4x6
4x6
4x6
GT-B
G
T
-
B
G
T
-
B
4x6
DRAG GT-B W/E.N.
G
T
-
B
G
T
-
B
2
-
2
x
42
-
2
x
4
DR
AG
G
T-B
W
/E
.N
.
2
-
2
x
4
2
-
2
x
4
2
-
2
x
4
1
SD2
1
SD2
1
SD2
S-2.4
PARTIAL FRAMING PLAN
PLAN 2 - LOT 6
H.M. A.D.
PROJECT NAME:
ARCHITECT:
DEVELOPER:
ADDRESS:
PLOT DATE:
DESIGNED BY:
SHEET NAME:
SHEET NUMBER:
PROJECT NUMBER:
DESCRIPTIONDATENO.
REVISIONS
aBPa
RMO Greenfield Estates
EL CAJON, CA
INGAMAC WAY
50011
04/13/2015
CHECKED BY:
BLDG. DEPT.03/31/20151
ALTERNATE ELEVATION (U.N.O.)
BASIC PLAN APPLIES TO
ALL INFORMATION FROM
ALTERNATE ELEVATION (U.N.O.)
BASIC PLAN APPLIES TO
ALL INFORMATION FROM
PWDHS 9'
FOYERHS 9'
KITCHENHS 9'
HALLHS 9'
GREAT ROOM22'9" x 17'7"
CPT 9'
NOOK11'2" x 15'6"
HS 9'
DINING12'1" x 13'10"
HS 19'-4"
OPT COVERED PATIOCONC 9'
PORCHHS 9'
DEN/OPT BR 413'4" x 11'6"
CPT 9' BA 3HS 9'
UP
CLOHS 9'
STAIRCPT VARIES
3-CAR GARAGE18'2" x 31'5"
HS 9'
211
'-10"
ST2
ST1
TD1
15'
-6"
112'-0"
TD1 TD1
28'
-0"
TD1
39'-8"
ST1
17'-5"
ST1
ST1
ST2
4SD1
4SD1
3SD1
3SD1
4SD1
4SD1
9SD1
9SD1
9SD1
5SD1
5SD1
5SD1
5SD1
2SD1
9SD1
9SD1
9SD1
9SD1
5SD1
P2 P3
6SD1
1ARNDPLY.
1ARNDPLY.
1ARNDPLY.
35'-8"
TD1
TD1
32'
-2"
DBL
23'
-2"
TD1
ST1
ST1
TD1
TD1
14'
-0"
ST1
ST1
14'-0"
ST1 ST1
12'-11"
TD1 TD1
15'-5"
TD1
TD1
24'
-10"
TD1
TD1
216
'-0"
TD1
TD1
P1P1
TD1
P2 P2P2
P1P1
1SD1
@OPT.
TD1
2SD1
1SD1
PER ARCH'LSLOPE
PER ARCH'LSLOPE
PERARCH.
PERARCH.
1SD1
1SD1
2SD1
1SD1
2SD1
1SD1
TD1
TD1
TD1
TD1
TD1
2SD1
1SD1
TD1
7SD1
P2 P1
P3
32'
-2"
DBL
14'-3"
TD1
NOTE FOR SLAB:
CONCRETE SLAB WITH #
REBARS @ 18" O/C EACH WAY.
5"
4
TD1 TD2
P1
P3
22'
-9"
P3
14'-3"
1AR
ND
PLY.
1ARNDPLY.
PAD SCHEDULE
SYMBOLS LEGEND
SDXX
FOUNDATION NOTES1. REFER TO GN & GD SHEETS FOR MORE INFORMATION.
SHEAR PANEL LENGTH AND NUMBER.REFER TO GN FOR PANEL TYPE, MIN. 2-2x4 @ EA. END.
DETAIL NUMBER DETAILSHEET NUMBER
HOLDOWN NUMBER
PAD NUMBER
REBAR
DROP IN SLAB (VERIFY PRIOR TO CONSTRUCTION)
FOOTING
HOLDOWN SCHEDULESIMPSON HOLDOWN NOTESSYM.
REFER TO DETAIL 19/SD1STHD10RJ
STHD14RJ
STHD10
STHD14
HDU8
HDQ8
HDU11
HDU14
HHDQ14
HTT5
HHDQ11
2. FOR SHEAR PANEL TYPES 3, 4 & 5 ON BOTH SIDES OF WALL, USE MIN. 3X6 SILL PLATES U.N.O.
REFER TO DETAIL 19/SD1
3. CONTRACTOR IS RESPONSIBLE FOR VERIFYING HARDY FRAMES MATCH TOP PLATE
HEIGHT & NOTIFY ENGINEER OF RECORD IF DIFFERENT THAN PLANS.
4. TOP OF ALL EXTERIOR FOOTING, GRADE BEAM FOOTING, PAD FOOTING, OR FLAG
POLE FOOTING TO BE MIN. 6" BELOW FINISH GRADE.
5. f'c=3000 psi FOR ALL GRADE BEAMS.
X
X'-X"X
ST1
ST2
ST3
ST4
TD1
TD2
TD3
TD4
TD5
TD6
TD7
6. FOR NON-SHEAR WALLS, MASA/MASAP MUDSILL ANCHORS CAN BE USED IN LIEU OF
ANCHOR BOLTS WITH END DISTANCE OF 4" MIN. PER ESR #2555.
X
USP HOLDOWN
STAD10
STAD14
STAD10RJ
STAD14RJ
PHD8
UPHD8
HTT22
UPHD11
UPHD14
---------
---------
2'-0" SQ. X 18" DEEP PAD W/ (3) #4 E.W.
2'-6" SQ. X 18" DEEP PAD W/ (4) #4 E.W.
3'-0" SQ. X 18" DEEP PAD W/ (4) #4 E.W.
PAD TYPESYM.
3'-6" SQ. X 18" DEEP PAD W/ (5) #4 E.W.
4'-0" SQ. X 18" DEEP PAD W/ (6) #4 E.W.
4'-6" SQ. X 18" DEEP PAD W/ (6) #4 E.W.
5'-0" SQ. X 18" DEEP PAD W/ (7) #5 E.W.
5'-6" SQ. X 18" DEEP PAD W/ (7) #5 E.W.
P1
P2
P3
P4
P5
P6
P7
P8
REF
PWDHS 9'
FOYERHS 9'
HALLHS 9'
3-CAR GARAGE18'2" x 31'5"
HS 9'
DINING12'1" x 13'10"
HS VLT
PANTRY
PORCHHS 9'
CLO
DEN/OPT BR 413'4" x 11'6"
CPT 9'BA 3
HS 9'
M/O
BUTLERS/WINE
UP
P2
S-3.1
FOUNDATION PLAN
PLAN 3
H.M. A.D.
PROJECT NAME:
ARCHITECT:
DEVELOPER:
ADDRESS:
PLOT DATE:
DESIGNED BY:
SHEET NAME:
SHEET NUMBER:
PROJECT NUMBER:
DESCRIPTIONDATENO.
REVISIONS
aBPa
RMO Greenfield Estates
EL CAJON, CA
INGAMAC WAY
50011
04/13/2015
CHECKED BY:
BLDG. DEPT.03/31/20151
ALTERNATE ELEVATION (U.N.O.)BASIC PLAN APPLIES TOALL INFORMATION FROM
PWDHS 9'
FOYERHS 9'
KITCHENHS 9'
HALLHS 9'
GREAT ROOM22'9" x 17'7"
CPT 9'
NOOK11'2" x 15'6"
HS 9'
DINING12'1" x 13'10"
HS 19'-4"
OPT COVERED PATIOCONC 9'
PORCHHS 9'
DEN/OPT BR 413'4" x 11'6"
CPT 9' BA 3HS 9'
UP
CLOHS 9'
STAIRCPT VARIES
3-CAR GARAGE18'2" x 31'5"
HS 9'
4X10
HDR
4X10
HDR
4x8 4X6
4X8
4X12 HDR 4X6
4X6
4X6
4X6
4X6
4X10 HDR 4X10 HDR
4X6
4X6 4X64X10 HDR
4X8
HDR
6X6
6X8
6X6
CONT. 3 1/2"X14" PSL 2.0E FL BM
4X8 HDR
4X10 HDR 4X12 HDR
4X6
3 1/2"X9 1/4" PSL 2.0E HDR CONT. 5 1/4"X11 7/8" PSL DROP 2.0E
3 1/
2"X1
4" P
SL 2
.0E
FL B
M
8 3/4"X16 1/2" GLB 24F-V4 TOP FL BM
3 1/2"X14" PSL 2.0E FL BM
3 1/2"X14"PSL 2.0E FL BM
6X6
211
'-10"
2-2X4
W/E.N.
4X6
15'
-6"
112'-0"
4X4
4X4
28'
-0"
22'
-9"
39'-8"
4X6
2-2X4
W/E.N.
6SD2
17'-5" 4X
4
4X6
7SD3
7SD3
7SD3
7SD3
7SD3
12SD3
1SD2
2SD2
7SD3
7SD3
1SD2
12SD3
14SD3
12SD3
2-2X
4W
/E.N
.
10SD3
10SD3
4X4TRIM
4X82B
SD3
2-2X
42-2X4
4X8
2ASD3
2-2X
4TR
IM
2-2X4
TRIM2-2X
4TR
IM
CONT.
1 3/
4"X1
4" P
SL 2
.0E
FL B
M
1 3/
4"X1
4" P
SL 2
.0E
FL B
M
2-2X6TRIM
4X6
TRIM
5BSD2
1ARNDPLY.
1ARNDPLY.
1ARNDPLY.
3 1/2"X9 1/4" PSL 2.0E DR
2-2X
4TR
IM
5ASD2 2-2X4
TRIM
5ASD2
3 1/2"X9 1/4" PSL 2.0E DR
2-2X4
TRIM
5ASD2
2-2X
4TR
IM
5ASD2
1HDRABV
1HDRABV
7SD3
35'-8"
4X4 4X4
TRIM
4X4
TRIM
W/E.N.
2-2X4
TRIM
4X4
2-2X4TRIM
4X10
HDR
5ASD2
5ASD2
2-2X4TRIM
2-2X4TRIM
5ASD2
5ASD2
5ASD2
5ASD2
4X4
2-2X4
TRIM
TRIM
5ASD2
5ASD2
2-2X4TRIM
2-2X4
TRIM
5ASD21
5ASD21
4X6TRIM
4X6
TRIM
CON
T. 6
x10
HDR
32'
-2"
DBL
TRIM
2SD2
1SD2
1SD2
2SD2
2-2X
4
4X6
6X6
10SD2
4X6
4X64X6
23'
-2"
4X4
4X4
9SD3
4 BAYS
5ASD3
4ASD2
8ASD24X4
4X4
4X4
4ASD2
2X6W/E.N.2X6W/E.N.
4X6
7SD3
4X6
2ASD3
2-2X
4
3SD3
2-2X4 3SD3
12SD21
4'-0
"
4X4
4X4
14'-0"4X
4
4X4
4SD3
2ASD3
4X6
TRIM
HGUS
HGUS
MIT.
MIT.
MIT. HGUS
12'-11"4X
4
4X41
5'-5"4X4
4X4
TRIM
TRIM
5ASD2
5ASD2
24'
-10"
4X4
4X4
3SD2
216
'-0"
4X4
4X4
7SD3
2-2X6
TRIM
2SD2
1SD2
3 1/2"X14" PSL FL BM
3 1/
2"X1
4" P
SL F
L BM
4X4
7ASD2
MIN 4 BAYS
5ASD3
5ASD2
5ASD21
5ASD21 5A
SD21
2-2X4
TRIM
5ASD2
TRIM
5ASD2
32'
-2"
DBL
MIN 4 BAYS
16ASD2
3 BAYS
5ASD3
2-2X4
CMST12 AT CORNER
14'-3" 4X
6
2-2x6 F.H. STUDS @ 16" O.C.
8SD3
4SD4
4SD4
CMST12 AT CORNER
CMST12 AT CORNER
4ASD2
8ASD2
8ASD2
5BSD2
14'-3"
6X6
4X4
1AR
ND
PLY.
1ARNDPLY.
6X6TRIM
5BSD2
6X6TRIM
5BSD2
11. ALL WOOD I-JOISTS SHALL BE IN COMPLIANCE WITH THE PROVISIONS OF APA PRI-400,EWS-Z725B (PERFORMANCE RATED I-JOIST STANDARD) OR ASTM D5055. QUALIFIED PRI-400,MANUFACTURED. SUBMIT SHOP DRAWING TO E.O.R. FOR REVIEW AND APPROVAL.
FRAMING NOTES
4. AT DOUBLE SIDED SHEAR WALLS, POST W/E.N. PER PLAN TO RECEIVE E.N. FROM BOTH SIDES.
FRAMING SCHEDULE
POST OR TRIMMER AS NOTED
SYMBOLS LEGEND
KEY NOTES
X
X
8. ALL BEAMS SHOWN ARE DROP (U.N.O.) ON PLANS.
5. WHEN MULTIPLE STUDS ARE USED INSTEAD OF A SINGLE POST, PLYWOOD SHEAR WALL TO BENAILED TO ALL STUDS RECEIVING HOLDOWNS.
10. USE USP " THF " HANGERS FOR CONNECTION OF I-JOISTS TO OTHER FRAMING MEMBERS(U.N.O.) AND " JUS " HANGERS FOR CONNECTION OF SOLID JOISTS.
6. APPLY SHEAR PRIOR TO FRAMING OF PERPENDICULAR WALLS. DO NOT BREAK SHEAR ATPERPENDICULAR WALL LOCATIONS UNLESS SPECIFICALLY DETAILED ON PLANS.
7. ALL VERTICAL PIPES THROUGH PLATES AND/OR SOLID RIM BEAMS MUST BE DRILLED CLEAN CUTW/ 1/16" TOLERANCE. DO NOT NOTCH OR CUT PLATES.
LINE OF 2X FLAT BLOCKING W/ EDGE NAIL. & CONTINUOUS CS16 STRAP OVER U.N.O. SEEPLAN FOR NUMBER OF BAYS.
DRAG STRUT W/E.N.. SEE PLANS/DETAILS FOR LENGTH. SUPPORT END W/ BLK'G
X
BLOCKED FLOOR DIAPHRAGM W/ 10d's @ 4" O.C. B.N., 6" O.C. E.N. & 12" O.C. FIELD.
BLOCKED ROOF DIAPHRAGM W/ 8d's @ 4" O.C. B.N., 6" O.C. E.N. & 12" O.C. FIELD.
PROVIDE SOLID BLOCKING
TRUSS HANGER BY TRUSS SUPPLIER
SHEAR TRUSS W/E.N. TRUSS TO TRANSFER 180 PLF MIN. (U.N.O.)
DRAG TRUSS W/E.N. TRUSS TO TRANSFER 1650# FORCE MIN. (U.N.O.)
CONTINUOUS FULL HT. BLKG. W/E.N. SEE PLANS FOR NUMBER OF BAYS ( U.N.O.)
(1) SIMPSON TS22 FLUSH BEAM TO DROP BEAM ( U.N.O.)
CONTINUOUS TIMBERSTRAND OR SPLICE PER PLAN.
13. USE 2X TRIMMER FOR HEADERS LESS THAN 6'-0" AND 2-2X FOR 6'-0" TO 10'-0" LONG SPAN INBEARING WALLS, U.N.O. ON THE PLAN. REQUIRED TRIMMER MUST BE APPLIED @ EACH END OFHEADER. SEE PLANS FOR HEADERS LARGER THAN 10'-0" LONG.
FLOOR TO FLOOR HOLDOWN PER SCHEDULE BELOW:
X
ALIGN STUD(S) / POST(S) WITH UPPER FLOOR STUD(S) / POST(S) AND PROVIDE SOLIDBLOCKING BETWEEN FLOOR ( PROVIDE E.N. WHEN POST IS LOCATED WITHIN S.W. )
CONTINUOUS LINE OF BLOCKING W/ EDGE NAILUNDER SHEAR WALL ABOVE W/ (1) CS16, U.N.O.
14. INTERIOR NON-BEARING WALLS MAY BE FRAMED WITH 2x STUDS AT 24" O.C., MAX.
DIRECTION OF ROOF MEMBER PER SCHEDULE,REFER TO HATCHED WALLS ON PLANS FOR INTERMEDIATE BR'GDIRECTION OF FLOOR MEMBER PER SCHEDULE,REFER TO HATCHED WALLS ON PLANS FOR INTERMEDIATE BR'G
DETAIL NUMBER DETAILSHEET NUMBER
KEY NOTE NUMBER
BEARING WALL
CALIFORNIA FRAMING
CONTINUOUS JOIST W/ E.N.
12. A 4x6 HEADER SHOULD BE USED AT ALL OPENINGS IN EXTERIOR & INTERIOR BEARING WALLSU.N.O. ON PLANS. ALL 4X4 TO 4X12 SIZES CAN BE SUBSTITUTED WITH A 2-2x TO MATCH THEDEPTH AND THE 2-2X SHALL BE PLACED ON END WITH 1/2" PLYWOOD SHIM BETWEEN. PROVIDE16d NAILS @ 16" O.C., STAGG., BOTH SIDES.
1A / SD-3
PERPLAN APPLY DETAIL
REFERENCE &
1B / SD-3
1C / SD-3
1D / SD-3
PERPLAN APPLY DETAIL
REFERENCE &
1E / SD-3
PERPLAN APPLY DETAIL
REFERENCE &
- -
- -
14" TJI 230 I-JOISTS @ 16" O.C.
14" TJI 230 I-JOISTS @ 19.2" O.C.
DESIGNED ROOF TRUSSES @ 24" O.C.
14" TJI 360 I-JOISTS @ 16" O.C.
J2
J3
T
J1
2 X 12 DECK JOISTS @ 12" O.C.
2 X 12 DECK JOISTS @ 16" O.C.
2 X 12 ROOF RAFTERS @ 16" O.C.
2 X 10 ROOF RAFTERS @ 16" O.C.
R2
R1
D1
D2
1F / SD-3
1G / SD-3
BXX
X'-X"X
A
B
C
D
E
F
G
H
JX X
X'-X"X
X
X
1
2
3
4
5
6
7
8
9
10
11
12
13
14
2. REFER TO DETAIL 3/GD FOR TYPICAL CONNECTION AT ALL INTERIOR NON-BEARING WALLS ATROOF LEVEL.
1 3/4" X 14" PSL FLUSH15
S-3.2
FLOOR FRAMING PLAN
PLAN 3 - LOT 4
H.M. A.D.
PROJECT NAME:
ARCHITECT:
DEVELOPER:
ADDRESS:
PLOT DATE:
DESIGNED BY:
SHEET NAME:
SHEET NUMBER:
PROJECT NUMBER:
DESCRIPTIONDATENO.
REVISIONS
aBPa
RMO Greenfield Estates
EL CAJON, CA
INGAMAC WAY
50011
04/13/2015
CHECKED BY:
BLDG. DEPT.03/31/20151
M BAHS 9'
WICCPT 9'
LAUHS 9'
BA 2HS 9'
WICCPT 9'
WICCPT 9'
OPT COVERED BALCONYDEX-O-TEX
GALLERYCPT 9'
HALLCPT 9'
OPENTO
BELOW
STAIRCPT VARIES
HALLCPT 9'
4X6
4X6
6X6
6X6
6X6
4X6
4X6
4X64X64X64X6
GT-B1
GT-B2 GT-B3
DRAG GT-B4 W/E.N.
6SD2
3 1/2"X9 1/4" PSL 2.0E HDR
17'
-6"
B
B
15'-9"
A A
18'-0"
A A
14'-5"
A
111
'-6"
B
B
28'-0"
B B
END TRUSS
1SD2
3SD2
2-2X6
7ASD2
MIN 4 BAYS
16ASD2
1SD2 1
SD2
1SD2
1SD2
2SD2
12SD2
12SD2
4X6
11SD2
2-2X
4TR
IM
2-2X
4TR
IM
2-2X4TRIM2-2X4
TRIM
2-2X4TRIM
5ASD2
2-2X4
TRIM
5ASD2
5ASD2
2-2X4
TRIM
2-2X
4TR
IM
5ASD2
13SD2
MIN
6'-0
"RR
W/E
N
14ASD2
25'-6"
A B5A
SD2
4X8 HDR 4X8 HDR
14'
-0"
B
B
14'
-0"
A
A
14'
-0"
A
A
3 1/
2"X9
1/4
" PSL
2.0
E DR
2-2X
4TR
IM
2-2X4
TRIM
1SD2
3 1/
2"X9
1/4
" PSL
2.0
E DR
1SD2
17SD2
2SD2
MIN
6'-0
"RR
W/E
N
14ASD2
1ARNDPLY.
1ARNDPLY.
1HDRABV
1HDRABV
5ASD2
15'
-1"
B
B
14'-5"
A
3-2X6
TRIM
8SD3
S-3.3
ROOF FRAMING PLAN
PLAN 3 - LOT 4
H.M. A.D.
PROJECT NAME:
ARCHITECT:
DEVELOPER:
ADDRESS:
PLOT DATE:
DESIGNED BY:
SHEET NAME:
SHEET NUMBER:
PROJECT NUMBER:
DESCRIPTIONDATENO.
REVISIONS
aBPa
RMO Greenfield Estates
EL CAJON, CA
INGAMAC WAY
50011
04/13/2015
CHECKED BY:
BLDG. DEPT.03/31/20151
M BAHS 9'
WICCPT 9'
LAUHS 9'
BA 2HS 9'
WICCPT 9'
WICCPT 9'
GALLERYCPT 9'
HALLCPT 9'
OPENTO
BELOW
STAIRCPT VARIES
DINING(OPEN TO BELOW)
HALLCPT 9'
AA
6X6
END TRUSS
4X6
4X6
4X6 4X6
2SD2
15'-5"
A
15'-5"
A8
SD3
14'
-0"
B
B
REF
PWDHS 9'
FOYERHS 9'
KITCHENHS 9'
HALLHS 9'
3-CAR GARAGE18'2" x 31'5"
HS 9'
GREAT ROOM22'9" x 17'7"
CPT 9'
NOOK11'2" x 15'6"
HS 9'
DINING12'1" x 13'10"
HS VLT
PANTRY
PORCHHS 9'
CLO
HWH
DEN/OPT BR 413'4" x 11'6"
CPT 9'BA 3
HS 9'
M/O
BUTLERS/WINE
UP
SINK W/ GD
DW
5 BU
RNER
STO
VEW
/HO
OD
36" C
OO
KTO
P
6'-0" x 5'-6"ISLAND
4X6
2-2X
4
4X61
SD2
TYP. 1SD2
1SD2
S-3.4
PARTIAL FRAMING PLAN
PLAN 3 - LOT 3
H.M. A.D.
PROJECT NAME:
ARCHITECT:
DEVELOPER:
ADDRESS:
PLOT DATE:
DESIGNED BY:
SHEET NAME:
SHEET NUMBER:
PROJECT NUMBER:
DESCRIPTIONDATENO.
REVISIONS
aBPa
RMO Greenfield Estates
EL CAJON, CA
INGAMAC WAY
50011
04/13/2015
CHECKED BY:
BLDG. DEPT.03/31/20151
ALTERNATE ELEVATION (U.N.O.)BASIC PLAN APPLIES TOALL INFORMATION FROM
ALTERNATE ELEVATION (U.N.O.)BASIC PLAN APPLIES TOALL INFORMATION FROM
1TYPICAL EXTERIOR FOOTING
FOOTING DIMENSIONS# OF
STORIESW
WIDTHD
DEPTHD1
DEPTH12 15" 18" 8"
12"24"18"3 & 4
SEE GENERAL NOTESUNDER "REINFORCED
CONCRETE" FORADD'L. REQUIREMENTS
3"@ VENEER MATCHITS THICKNESS & NOTTO BE LESS THAN 3"
ALT.
7" EMBEDMENT. (FOR DUALPOUR, THE 7" EMBEDMENTINTO THE 1st. POUR STARTSFROM THE COLD JOINT)
PLYWOODPER PLAN
EXTERIOR FINISHw/ G.I. BASE SCREED.SEE ARCHITECTURAL
NOTES:- VAPOR BARRIER TO HAVE MIN. 6" LAP AT ALL SEAMS PER MANUF. (U.N.O.).- VERIFY ALL INFORMATION PER UPDATED SOILS REPORT.- "D" IS EMBEDMENT DEPTH BELOW LOWEST ADJACENT GRADE.
* SAND OVER VISQUEEN CAN BE ELIMINATED UPON VERIFICATION w/ SOILS ENGINEER, & USE OF w/ C RATIO OF .45 WHEN CONC. CAN BE ASSURED TO BE CURED PROPERLY.SEE SOILS REPORT RECOMMENDATIONFOR SAND OVER AND BELOW MOISTUREBARRIER.
MASA/ MASAPINSTALLATION
NOTES FOR DUAL POUR:- (FOR DUAL POUR DEFINITION, SEE NOTE 14 UNDER FOUNDATION NOTES ON GN).- USE #4 DOWELS @ 18" o.c. EMBED MIN. 12" ON FIRST POUR. DOWELS ARE REQUIRED AT ANY OF THE FOLLOWING CONDITIONS: 1. SOILS WITH 20 < E.I.< 50 & OR COMPRESSIVE SOILS w/ DIFF. SETTLEMENT OF 1" MAX. IN 40'-0". 2. USING MASA/ MASAP IN LIEU OF ANCHOR BOLTS. 3. ANCHOR BOLT EMBEDMENT LESS THAN 7" INTO 1st POUR.
18"
2x P.T.D.F. SILL (USE 3xWHERE INDICATED ONPLANS) w/ 5/8" DIA. ANCHORBOLTS OR MASA/ MASAP.SEE FOUNDATION PLAN &NOTES UNDER "FOUNDATION"ON GN SHEET(S) FOROTHER REQUIREMENTS
INTERIORFINISH2x STUDS@ 16 "o.c.
CONC. SLAB PER PLANSLAB. USE 6x6-10x10WWM AS AN ALTERNATIVE(U.N.O.) PER SOILS REPORT
2" SAND OVERMIN. 10 MIL VAPOR BARRIEROVER 4" OF COARSE GRAVELOR AS RECOMMENDED BYSOILS ENGINEER. SEE ALSOTHEIR RECOMMENDATIONS.*
TOP OFNATURAL GRADEOR COMPACT FILL
(2) #4 REBAR CONT.T & B (U.N.O.)
W
N/A N/A N/A
15" MIN. @ 15" MIN.
8" MIN.
INTERIOR BEARING FOOTING
NOTES:1. SEE DETAIL #1 FOR LEGEND & INFORMATION NOT SHOWN.2. IN LIEU OF ANCHOR BOLTS USE SHOT PINS AS PER GENERAL NOTES FOR NON- SHEAR WALLS.
PARTY WALL W/RAISED CURBPARTY WALL
W
ADD #4 HORIZON.@12"o.c.
SEE NOTE FOR DUALPOUR ON DETAIL #1.
2x P.T.D.F. SILLw/ 5/8"ø ANCHOR BOLTSOR MASA/MASAP.
INTERIOR FINISH.
2X STUDS@ 16 " O.C.
#4 VERT. @18"o.c. WHEN"H" EXCEEDS 8".
SEE NOTE FOR DUALPOUR ON DETAIL #1.
CONC. SLABPER PLAN
SEE DETAIL 1 FORSLAB UNDER LAYER
2x P.T.D.F. SILLw/ 5/8"ø ANCHOR BOLTSOR MASA/MASAP.
CONC. SLABPER PLAN
2
EXT. BEARING GARAGE CURB
3"8"@ VENEER MATCHITS THICKNESS & NOTTO BE LESS THAN 3"
W
ISOLATED SLAB FROMSTEM WALL (USE 1/2"FIBERBOARD MATERIAL)
7" EMBEDMENT. (FOR DUALPOUR, THE 7" EMBEDMENTINTO THE 1st. POUR STARTSFROM THE COLD JOINT)
EXTERIOR FINISHw/ G.I. BASE SCREED.SEE ARCHITECTURAL
2x P.T.D.F. SILL (USE 3xWHERE INDICATED ONPLANS) w/ 5/8" DIA. ANCHORBOLTS OR MASA/ MASAP.SEE FOUNDATION PLAN &NOTES UNDER "FOUNDATION"ON GN SHEET(S) FOROTHER REQUIREMENTS
2x STUDS@ 16 "o.c.
REBARPER DETAIL 1
NOTE:SEE DETAIL #1 FOR LEGEND& INFORMATION NOT SHOWN.
CONC. SLABPER PLAN
3
HOUSE TO GARAGE/APRON
SEE DETAIL #3
CONC. CURBBEYOND
DRIVEWAYSLAB
WREBARPER DETAIL 1
W
7" EMBEDMENT. (FOR DUALPOUR, THE 7" EMBEDMENTINTO THE 1st. POUR STARTSFROM THE COLD JOINT)
4"
SEE DETAIL #3
CONC. SLAB PER PALN.USE 6x6-10x10WWM AS AN ALTERNATIVE(U.N.O.) PER SOILS REPORT
2x STUDS@ 16 "o.c.INTERIORFINISH
2x P.T.D.F. SILL (USE3x WHERE INDICATEDON PLANS) w/ 5/8" DIA.ANCHOR BOLTS ORMASA/ MASAP. SEEFOUNDATION PLAN& NOTES UNDER"FOUNDATION" ONGN SHEET(S) FOROTHER REQUIREMENTS
REBARPER DETAIL 1
NOTE:SEE DETAIL #1 FOR LEGEND& INFORMATION NOT SHOWN.
CONC. SLAB PER PLAN.
SEE DETAIL 1 FORSLAB UNDER LAYER
4
HOUSE TO PORCH
NOTE:SEE DETAIL #1 FOR LEGEND& INFORMATION NOT SHOWN.
W
6"MIN.
FINISHGRADE
SLOPED PPRCHSLAB TO DRAIN
PORCH SLABSLOPE TO DRAIN
FACE OF STUDS
SEE DETAIL #3
#3x24" DOWELS@ 24"o.c.
CONC. SLAB PER PALN.USE 6x6-10x10WWM AS AN ALTERNATIVE(U.N.O.) PER SOILS REPORT
ISOLATED PAD FOOTING
NOTES: 1. SEE DETAIL #1 FOR LEGEND AND INFORMATION NOT SHOWN 2. 4x4 POSTS CAN BE REPLACED WITH 2-2x4 AS LONG AS NAILS ARE MAINTAINED WITH MIN. EDGE DISTANCE AS REQUIRED BY THE MANF. SPEC. & S.W. EDGE NAILS STAGG ON BOTH STUDS.
INTERIOR EXTERIOR
SEE PLANS 24" SQ. MIN.
FACE OF STUD
CENTERLINE OF POSTAND PAD FOOTINGCONC. SLAB PER PLAN.
PAD REINFORCEMENT,SEE PLANS
PAD REINFORCEMENT,SEE PLANS
CENTERLINE OF POSTAND PAD FOOTING
POST IN WALL OR USECOLUMN BASE, SEE PLAN
5
6
EQ EQ
STEP AT CONCRETE SLAB
6"6"6" 6"
NOTES:- SEE DETAIL #1 FOR LEGEND AND INFORMATION NOT SHOWN.- BEND REBARS IF REQUIRED & LAP MIN. 48 BAR DIAMETERS.
#4 @ 24" O.C.
18"
6"CONC. SLAB PER PLAN.
LOCATE #4 BAR
#4 HORIZ.@ 24" O.C.
12
7
RAISED CURB
1'-10" MIN.
NOTE: 1. 4x4 POSTS CAN BE REPLACED WITH 2-2x4 AS LONG AS NAILS ARE MAINTAINED WITH MIN. EDGE DISTANCE AS REQUIRED BY THE MANF. SPEC. & S.W. EDGE NAILS STAGG ON BOTH STUDS.
TOP OF SLAB AT GARAGE
TYPICAL CONT. #4 TOPAND BOTTOM (U.N.O.)ADD #4 BAR BENT DOWN
INTO FOOTING AT CURB
3" CLEARANCE. TYPICAL
POST PER PLAN
ANCHOR BOLT. SEE PLANSFOR SIZE AND SPACING
SILL PLATE
8
TIE BEAM
REFER TOARCH. 6"MIN.
EQ
12" MIN.
3"CLR.
TYP. STEMWALL FT'G.
TIE BEAM
EQ
12 MIN.
3"CLR.
FINISH GRADE
(2)#4 T & B w/ 2'-0" MIN.LAP & EMBEDMENT INADJACENT SLAB & FTG.
(2)#4 T & B w/ 2'-0" MIN.LAP & EMBEDMENT INADJACENT SLAB & FTG.
PROVIDE #4 VERT.@ 18" O.C. ONLY IF "D"EXCEEDS 18" TALL.
NOTES: - SEE DETAIL #1 FOR LEGEND AND INFORMATION NOT SHOWN.
(1)#4 T CONT.
TYPICAL CONTROL JOINT
NOTE: PROVIDE CONTROL JOINT AT 10'-0" EACH WAY (U.N.O.) SEE DETAIL #1 FOR LEGEND & INFORMATION NOT SHOWN PROVIDE SAW CUT WITHIN 24 HOURS OF POUR
SAW CUT HAND TOOL JOINT
1/8" MAX.RADIUS1/8" MAX.
CONC. SLAB PER PLAN
9
10
NON-BEARING INTERIOR WALL
SEE FOUNDATIONNOTE 2 ON SHEET GN
NOTE: SEE DETAIL #1 FOR LEGEND & INFORMATION NOT SHOWN
4" CONC. SLAB w/ #3 BARS@ 18"o.c. E/ W @ MID HT.OF SLAB. USE 6x6-10x10WWM AS AN ALTERNATIVE(U.N.O.) PER SOILS REPORT
11
PIPE COLUMN
3"ø CONCRETE FILLEDPIPE BUMPER GUARD
8"2" 2"
FOOTING CONNECTING
JOINT AS REQUIRED
4" CONC. SLAB w/ #3 BARS@ 18"o.c. E/ W @ MID HT.OF SLAB. USE 6x6-10x10
WWM AS AN ALTERNATIVE(U.N.O.) PER SOILS REPORT
12
BUILT-UP SLAB
ROUGHEN SLAB CONTACTSURFACES TO RECEIVECAST-ON SLAB 2ND POUR
#4 @ 16"o.c.EA. WAY
4" THICK MIN. BUILT-UPSLAB OVER COMPACTEDMOISTENED SAND BASE
SAND BASE MAY BEREPLACED W/SOLIDCONC. AT CONTRACTOR'SOPTION
A.B.,HD.B.&STRAPSLONG ENOUGH FORMIN. EMBEB. INTOFIRST POUR OFSLAB OR FOOTINGS
NOTES: 1. WHEN POST LOAD BEARS @ CAST-ON SLAB, THICKEN CONCRETE MIN. 24"SQ. ALL THE WAY TO LOWER SLAB. 2. SEE DETAIL #1 FOR LEGEND & INFORMATION NOT SHOWN.
13
3"BATTER
SEE PLANS
COLUMN BASE
MULTI-STUD ORPOST PER PLAN
(2)#4 E.W.PER PLAN
PLATE & ANCHORBOLTS WHEREOCCURS
PAD FOOTINGPER PLAN
TOP OF CONCRETE SLABWHERE OCCURS
SIMPSON COLUMNBASE CB/LCB/CBSQPER PLAN
#3 MIN. "V" BARBENT 12" 12"THRU STIRRUPOF COLUMN BASE
MULTI-STUD ORPOST PER PLAN
SIMPSON COLUMNBASE CB/LCB/CBSQPER PLAN
3"CLR.
#3 MIN. "V" BAR BENT12" 12" THRU STIRRUPOF COLUMN BASE
PONY WALL
ENLARGEDPLAN VIEW
2x4 P.T.D.F. PLATE(NOTCH AROUNDSTEEL ANGLE)
SHOVEL FOOTING12" CONCRETEEMBEDMENT
3x3x1/4x2'-6"LONG STEELANGLE
3x3x1/4x2'-6"LONG STEELANGLE
2x4 P.T.D.F.MEMBER
14
15
UP TO 1" IN 40'
SD-1
STRUCTURAL FOUNDATION
DETAILS FOR VERY LOW
&LOW EXPNASIVE SOILS
WITH E.I. < 50 &
COMPRESSIVE SOIL
H.M. A.D.
16
17
18
POST TO FOOTING AT DECK
SEE PLAN
EXTEND L5x5x1/2INTO CONC.FOOTINGAS SHOWN
PROVIDE STE210WATERPROOFMEMBRANEBETWEEN POSTBASE AND TOPOF CONC. FOOTING
5"
SEE PLAN
DETAIL "A"DETAIL "B"
C.L.
6x6 POST(U.N.O.)
MULTI -STUD ORPOST PER PLAN
SIMPSON CB
5/8"ø M.B. WITH2 1/2x2 1/2x1/4"WASHER
L 5x5x1/2 BOTTOMOF POST
A-A
NOTES: 1. AS AN ALT. TO L5x5x1/2 ANGLE, EMBED 6x6 P.T.D.F. CONFORMING TO AWPA STANDARD UI & M4 INTO FOOTING MIN. 24". PROVIDE ADEQUATE WATER PROOFING. 2. WHEN DECK IS ADDED AFTER CONSTRUCTION OR DECK SYSTEM IS NOT DRAGGED INTO THE BUILDING, USE DETAIL"B". 3. WHEN DECK SYSTEM IS DRAGGED INTO THE BUILDING PER DETAIL 4/SD2 OR DETAIL 14/SD2, USE DETAIL "A".
STEPPED FOOTING
1 1/2"
48 db24" MIN.
1.5 "S"
FT'G. REIN'F.PER DETAIL
NOTES: 1. "S" SHOULD BE MAX 18". 2. "D" IS OVERALL DEPTH OF FTG. 3. BEND REBARS IF REQUIRED & LAP MIN. 48 BAR DIAMETER. 4. REINFORCEMENT TO MATCH FOUNDATION DETAILS.
TYPICAL TRENCH @ FOOTINGS
NOTE: - CONTRACTOR IS RESPONSIBLE FOR PROPER SHORING WHEN REQUIRED.
TRENCH PARALLELTO FOOTINGS
ADD (2)#4x4' LONGCENTER @ PENETRATION
TRENCH PERPENDICULAR TO FOOTING
COMPACTEDFILL
1
2
18"
10'-0" MIN.
12
CREATE PIPESLEEVE 2" LARGERTHAN PIPE
FINISH GRADE
BOTTOM OF TRENCHEXCV. NOT TO EXTENDBELOW THIS LINE
BACKFILL TRENCHEXCV. PER SOILSREPORT
SEE
SHEE
T SD
-1A
FOR
DETA
ILS 19
THR
OUGH
21 S
D-1
PROJECT NAME:
ARCHITECT:
DEVELOPER:
ADDRESS:
PLOT DATE:
DESIGNED BY:
SHEET NAME:
SHEET NUMBER:
PROJECT NUMBER:
DESCRIPTIONDATENO.
REVISIONS
aBPa
RMO Greenfield Estates
M&O Investments
EL CAJON, CA
INGAMAC WAY
50011
04/13/2015
CHECKED BY:
BLDG. DEPT.03/31/20151
CAST-IN-PLACE FOUNDATION HOLDOWNS (THIN-SLAB CONDITION) - MONOLITHIC (1-POUR)
NOTES: 1. BOLTS SHALL BE TIED IN PLACE PRIOR TO FOUNDATION POUR, U.N.O. 2. COMPLY WITH THE MANUF. MOST CURRENT LITERATURE,SPECIFICATIONS, AND ICC-ESR/LARR REPORT 3. POST TENSION CABLE MAY NOT BE COUNTER AS REQUIRED HOLDOWN REBAR 4. EXISTING FOOTING REBAR(S) MAY BE COUNTED AS REQUIRED HOLDOWN RABAR(S) 5. CONCRETE COMPRESSIVE STRENGTH MUST NOT BE LESS THAN 2.500 psi 6. HOLDOWNS MAY BE RAISED OFF MUD-SILL TO ACCOMMODATE AN ANCHOR MISLOCATED NO MORE THAN 1 1
2".HOLDOWN SHALL BE RAISED OFF SILL AT LEAST 3" FOR EVERY 1/4" THAT ANCHOR IS OFFSET FROM MODEL'S CENTERLINE (MAX.18").BOLT SLOPE SHALL BE NO GREATER THAN 1:12 (5%).REFER TO MANUF.SPECS. 7. LOADS ARE BASED ON :DOUG- FIR(DF),CRACKED CONCETE,SDC D & e 6" CURB, 12" (BELOW GRADE) x 13 1
2" (WIDE) MONOLITHIC(1-POUR) FTG. 8. FOR ALL INFORMATION NOT SHOWN,REFER TO DETAIL 1/SD1 OR 1/PT1 9. de IS MEASURE TO TOP OF WASHER PLATE PER MANUF.SPECIFICATIONS. 10. CACULATED TOTAL BAR LENGTH IS THE RESPONSIBILITY OF THE CONTRACTOR WHO MUST TAKE INTO CONSIDERATION ALL ASPECTS OF THE PLANS AND HIS CONSTRUCTION TECNIQUES. 11. LARGER DIMENSION AND/OR THICKNESS WASHERS MAY BE USED BASED UPON COST OR AVALABILITY MUTIPLE WASHERS MAY BE USED TO ACCOMPLISH TOTAL REQUIRED THICKNESS 12. STANDARD CUT WASHERS IS REQUIRED UNDER ANCHOR NUT AND BETWEEN NUTS AND WOOD.
INTERIOR CONDITIONEXTERIOR CONDITION
STHD PER PLANAPPLY ON SHEATHING
(WHERE OCCURS)
ALIGN CENTER OFA.B. WITH CENTER OF
WALL (MIN 1-3/4") AND CENTER OFCONCRETE PAD
SEE HOLDOWNMANUF.SPECS.FOR REQUIREDBOLT STANDOFF
FT"G BARSPER CHART
ANCHOR BOLT ASSEMBLYPER FIGURE BELOW
EQ.EQ.
SQUARE PAD(SIZE PER CHART BELOW)
EQ.EQ.
SQUARE PAD(SIZE PER CHART BELOW)
SIMPSONHOLDOWN
TYPE
HDU2 5/8" 1.5"x1.5"x1/4"
ALL-THREAD ROD ANCHOR BOLTASTM F1554 GR.36,Fy= 36 ksi,Fu= 58 ksi
RODDIAMETER
PLATE WASHERF436
RODEMBEDMENT
de
SQUAREPAD SIZE
ALT. SIMPSONPRE-ASSEMBLED
BOLT
FOOTING BARS
MINBARS
BARS LENGTHPAST EA.SIDEOF ROD/BOLT
7" 19" PAB5 (1) - T&B 2'-0"
HTT4 5/8" 1.5"x1.5"x1/4" 7" 19" PAB5 (2) #4-T&B 2'-0"
HTT5 5/8" 1.5"x1.5"x1/4" 7" 19" PAB5 2'-0"
HDU8 7/8" 2.25"x2.25"x3/8" 11" 31" PAB7 3'-0"
HDQ8 7/8" 11" 31" PAB7 3'-0"
HDU11 1" 13" 36" PAB8 3'-0"
HDU14 1" 13" 36" PAB8 3'-0"
HD19 1-1/4" 3.0"x3.0"x1/2" 16" 48" PAB10 4'-0"
2.25"x2.25"x3/8"
2.5"x2.5"x3/8"
2.5"x2.5"x3/8"
(3) #4-T&B
(2) #5-T&B
(3) #5-T&B
MAX. ALLOWABLESPALL = 1"
GRADE OR FIN. SURFACE
TOTAL (1)- #4 BARL=28" PAST EACHSIDE OF STRAP.
4- 3/4" to 5- 1 4"
GAR. SLABF.F.
F.F.F.F.
ALTERNATE CURB CONDITION
SIMPSONPRODUCT
TYPE
STHD10 ESR- 2920
PRODUCT RESEARCH REPORT
ICC-SEREPORT
LARRREPORT
LAPMOREPORT
STHD14
HTT
HDU
HDQ
HD
ESR- 2920
N/A
ESR- 2330
ESR- 2330
N/A
N/A
N/A
RR - 25818
RR - 25720
RR - 25720
RR - 25828
N/A
N/A
N/A
N/A
ER- 130
ER- 143
ALT. EXTERIORCURB CONDITIONREFER TO EXT. CON. FORALL INFO. NOT SHOW
ALT. INTERIORCURB CONDITIONREFER TO INT. CON. FORALL INFO. NOT SHOW
STHD STRAP2,7,8
REFER TO STANDARD COND.ALL INFO. NOT SHOW
ALL-THREAD ROD
GRADE OR FIN. SURFACE
(2) #4-T&B
(2) #4-T&B
(2) #5-T&B
1,7 52,6
ANCHOR RODF1554, Gr. 36
HEX NUTA563
PLATE WASHER F436
HEX NUTA563
ACHOR BOLTASSEMBLY
3,4
4
11 9
8
UP TO 1" IN 40'
SD-1A
STRUCTURAL FOUNDATION
DETAILS FOR VERY LOW
&LOW EXPNASIVE SOILS
WITH E.I. < 50 &
COMPRESSIVE SOIL
X X
20
24" LAP MIN.
24" LAP MIN.
24" LAP MIN.
REINFORCEMENT DETAIL
21
BEND
R= 5(d) FOR #14 THRU #18
LAP SPLICE
STIRRUP
TIE OR HOOK
MADE COLD- ALL BENDS SHALL BE STIRRUP ALT. 135° BENDS
- PUT CROSSTIE W/ EACH
D= 4(d) FOR #3 THRU #5D= 6(d) FOR #6 THRU #8NOTES:
CROSSTIE
MEMBER BELOW, EXCLUDE CONCRETE IS CAST IN THE THAN 12 INCHES OF FRESH BARS SO PLACED THAT MORE FOR TOP BARS (HORIZONTAL * INCREASE LENGTH BY 30%
WIRE TIE END
WALLS)
48(d) MASONRY (U.N.O.)48(d) * IN CONCRETE
90° BEND
8(d)R
R= 4(d) FOR #9 THRU #11R= 3(d) FOR #3 THRU #8
2 1/2" MIN.8(d)
180° BEND
R
4(d) OR
TYP. REINFORCING DETAILS
19
PROJECT NAME:
ARCHITECT:
DEVELOPER:
ADDRESS:
PLOT DATE:
DESIGNED BY:
SHEET NAME:
SHEET NUMBER:
PROJECT NUMBER:
DESCRIPTIONDATENO.
REVISIONS
aBPa
RMO Greenfield Estates
M&O Investments
EL CAJON, CA
INGAMAC WAY
50011
04/13/2015
CHECKED BY:
BLDG. DEPT.03/31/20151
B.N.
TRUSS BYMANUFACTURER.
8d @ 6"o.c.B.N.
SIMPSONA35, LS50, LTP4@ PER SHEARWALL SCHEDULE
SIMPSON HI @EVERY TRUSSUSE LGT FORGIRDER TRUSSWIDTH OF LGTTO MATCHNUMBER OF PLYSOF GIRDER TRUSS
PLY WOODSHEATHING
2x BLK'G
(2)2xTOP PL
SIMPSON HI @EVERY TRUSSUSE LGT FORGIRDER TRUSSWIDTH OF LGTTO MATCHNUMBER OF PLYSOF GIRDER TRUSS
TRUSS BYMANUFACTURER
ALT. LOC.OF SHEARPANEL.
SHEAR PANELPER PLANON 2x @ 16"o.c.MAX. STUD
2x BLK'GPER PLAN
2x DRAFTERw/ MIN. 3'-0" LAPw/ 16d @ 6"o.c.STAGG OR TRUSSTOP CHORD
B.N.
SIMPSONA35, LS50, LTP4@ PER SHEARWALL SCHEDULE
SIMPSONA35, LS50, LTP4@ PER SHEAR WALLSCHEDULE
SIMPSON HI @EVERY TRUSSUSE LGT FORGIRDER TRUSSWIDTH OF LGTTO MATCHNUMBER OF PLYSOF GIRDER TRUSS
MAX. GAP BETWEEN BLK'G. &TOP PLATE FOR HI & LS50TO BE 1/2" & FOR A35, TO BE 1/4"
SHEAR PANEL PER PLANON 2x @ 16"o.c. MAX. STUD RBC INSTALLATION
ALT.LOCATIONOF HI/LGT
SHEAR PANEL TYPE 2TYPICAL BETWEEN TRUSSES
2x BLK'GPER PLAN
SIMPSONA35, LS50, LTP4@ PER SHEARWALL SCHEDULE
8d @ 6"o.c.B.N.
2x BLK'G
2x BLK'G
SHEAR TRANSFER DETAIL
NOTES: 1. DIAGONAL BRACE CAN BE OMITTED AT LOCATION OF INTERSECTING WALLS AND WHEN FULL HT. STUDS USED TO BOTT. OF OUTRIGGER. 2. FOR FLAT CONC. TILE ROOFING, ALLOW ROOF RAFTERS TO FLOAT AND NAIL TO TOP PLATE AFTER ROOF IS LOADED TO AVOID UNEVEN RAFTER DEFLECTION.
BRACELENGTH
BRACESPACING
BRACESIZE
CONN.*
H2.5H2.5
EA. BRACE(6)16d
EA. BRACE
(6)16d2x4
(2)2x4
(2)2x46'-0"o.c.
8'-0"o.c.
6'-0"o.c.
L=10'-4"
L=5'-8"
L=5'-8"
* AS ALTERNATE TO H2.5, USE H3, A34 OR A35. UNSUPPORTEDHEIGHT
SIZE
2x42x62x8
LESS THAN 14'LESS THAN 20'LESS THAN 24'
ALT.
ALT.
ALT.
B.N.
ALTERNATE COND. w/ROOF RAFTER NEXT TOWALL w/ 16d @ 8"o.c.TO TOP PLATE
SHIM AS REQ'D
SHEAR PANELWHERE OCCURS
FULL HT. BALLOON FRAME STUDS@ 16"o.c. MAX. U.N.O. TO BOTT. OFOUTRIGGER/GABLE ENDTRUSS/SCISSOR TRUSS. SIZEPER SCHEDULE U.N.O.
BOUNDARYNAILING
2x FLAT BLOCKS w/16d @ 4"o.c. TOPLATE BELOW
2x BACKING w/ 8dCOM @ 6"o.c. FACENAILS TO TOP PLATES
2x4 x2'-0" LONGCENTERED @ BRACEw/(5)16d TO TRUSS
(1)A35 E/S OFEACH BRACE
2x FASCIA BOARDWHERE OCCURS
BOUNDARY NAILING
SHIM AS REQUIRED
8d COM TOENAILS @ 6"o.c.
LS50 OR LTP4 SPACING PERSW SCHEDULE (ATNON-SHEAR WALL, SPACING@ 48"o.c. MAX.). OMIT IFPLYWOOD IS NAILED TOBOTTOM CHORD OF TRUSS SHEAR PANEL
WHERE OCCURS
ROOF SHEATHING w/LINE OF E.N. @ BLOCKING
2x4 FLAT STRONG BACKACROSS MIN. (4) ROOFTRUSSES @ 8'-0"o.c.USE (2)16d TO CONNECTTO EACH TRUSS
(3)16d EA. END OF TRUSS TO BLK'G
MAX. UNSUPPORTEDLENGTH OF 2x4 TO BE6'-0". USE LATERALBRACING FOR LENGTH >6'-0"
BRACING MEMBERFOR TRUSSDEEPER THAN4'-0" PER TABLEBELOW
STRUCT. GABLE ENDSHEAR TRUSS TOTRANSFER 240 PLFFROM TOP TO BOTT.CHORD (U.N.O.)
NOTCH TRUSS TOP CHORD OR RAFTERWHERE OCCURS TO RUN 2X FLATOUTRIGGERS @ 4'-0"o.c., FOR EAVES UPTO 12" & 2'-0"o.c. FOR EAVES UP TO 24"DO NOT OVER CUT. NAIL w/(2)16d @ EA. END
AB
ACONN.
A
H2.5EA. BRACE
(6)16dEA. BRACE
SHEAR TRANSFER DETAIL
SHEAR TRANSFER DETAIL
4" MAX.OFFSET
SHEAR TRUSS TO TRANSFER200 PLF FROM TOP CHORDTO BOTTOM U.N.O.
A35'S EQUALLY SPACED PERSHEAR WALL SCHEDULE (ATNON-SHEAR WALL, @ 48" O.C.MAX.). CONNECT A35's AFTERROOF IS IN PLACE
2X8 (MAX.) NAILER WITH 10dCOMMON NAILS TO PLATE &TRUSS. USE SAME SPACINGAS EDGE NAILS OF SW TYPEBELOW
ALT. LOCATION OF A35 IFTRUSS IS OFFSET
E.N.ROOF SHEATHING
TYPICAL TRUSSES
E.N.
SEE PLANFOR TYPE
SHEAR TRUSS TO TRANSFER200 PLF FROM TOP CHORDTO BOTTOM U.N.O.
SEE PLAN FOR TYPE
1
2
3
ALT. CONDITION
ABCD
CS16x36"ST6236MST48MST60
(32) 8d BOX/SINKER(40) 16d SINKER(50) 16d SINKER(66) 16d SINKER
1700#3230#4460#5653#
8'-0" U.N.O.14'-0"
CONTINUOUSCONTINUOUS
STRAP NAIL SIZE &QUANTITIES CAPACITY DRAG STRUT.
LENGTH
ALT. LOCATION.
PLYWOOD SHEATHING w/ E.N. ALONGDRAG LINE. SEE TABLE BELOW.
FLAT @ CS16.2X FULL HT.HEAD OUT
IF REQUIRED4X DRAGSTRUT. ALT 2x
STRAP SHOULD BE CENTERED @ SPLICE POINT.
DRAG STRUT w/ E.N.PER PLANS.IF NOTCONTINUOUS SPLICEPER TABLE BELOW.
DRAG DETAIL
SIDE VIEW END VIEW
2x KING STUDSEA. SIDE OF BEAMw/ 16d @ 16"o.c. TO POSTMIN. (5)16d TO BEAM
POST PER PLAN
BEAMPER PLAN
SIMPSON TRAPEA. SIDE OFBEAM TO POST
NOTE:1. ADD SHIMS AS REQUIRED IF THERE IS DBL.TOP PLATE BTWN. BEAM & POST, INCREASE LENGTH OF STRAP TO ACCOMMODATE.2. FILL ALL STRAP HOLES WITH NAILS.
BEAMPER PLAN
STRAPEA. SIDE
CAPACITY OVERALL LENGTHOF EA. STRAP
A
B
C
MSTA12(1) CS16
(2) CS162900#
-
5600#
12"
24"
24"
POST & BEAM CONNECTION
CALIF. FRM'G SHEAR DETAILCALIF. FRM'G (PLAN VIEW)
SECTION C-CALT. CONVENTIONAL
CALIF. FRAMING
CALIF. FRAM'G. @ RIDGECONNECTION DETAILA B
*ICC ESR#2605
CC
B.N.
PREFABRICATEDVALLEY TRUSS PERMANUFACTURER
R/ R OR TRUSSPER PLAN
ROOFSHEATHING
SIMPSON *VTC2 CLIPS@ EA. END OF VALLEYTRUSS WITH (5)10dx1 1/2NAILS TO VALLEY TRUSS& (4)10dx1 1/2 NAILS TOROOF FRAMING BELOW
2x R/ R @ CA. FRAMING.USE 2x4 @ 24"o.c. FOR MAX.SPAN OF 6'-0" & 2x6 @ 24"o.c.FOR MAX. SPAN OF 10'-0".& TOE NAIL w/(3)8d
2x6 PURLIN & 2x4KICKER @ 8'-0"o.c.MAX. TO LIMIT R/ RSPAN @ CALIF. FRAMING
MIN. 1x CONT. BOARDw/(3)16d TO EACH ROOFFRAMING ELEMENT
ROOFSHEATHING
R/ R OR TRUSSPER PLAN
2x R/ R @ CA. FRAMING.USE 2x4 @ 24"o.c. FOR MAX.SPAN OF 6'-0" & 2x6 @24"o.c. FOR MAX. SPANOF 10'-0". & TOE NAIL w/(3)8d
(1)BAY WIDTHx 30" ACCESS& VENTILATION OPENING PERARCHITECTURAL. PROVIDE2x BLKG. & BOUNDARY NAILINGOF ROOF SHEATHINGAROUND OPENING
A
B
R/ R OR TRUSSPER PLAN
MIN. 1x CONT. BOARDw/(3)16d TO EACH ROOFFRAMING ELEMENT
4
5
6
DRAG DETAIL
CAPACITY**
1700#3400#4585#6490#
ENDLENGTH
NAIL SIZEAND SPACINGSTRAP
CS16(2) CS16
CMSTC16CMST14
ABC*D*
3'-0"3'-0"6'-0"6'-0"
8d BOX/SINKER @ 4 1/8"8d BOX/SINKER @ 4 1/8"
16d SINKER @ 4 1/2"16d SINKER @ 3 1/2"
TRUSS IN LINE
SIDEVIEW
SIDEVIEW
PLANVIEW
TRUSS OFFSET
SIMPSON STRAP CUT TOFIT ON WALL AS SHOWN &ACROSS ALL BAYS OF BLKG.AS REQ'D. MIN. (4) BAYS w/ MIN.(3) NAILS TO EACH BLOCK.NAILS PER SCHEDULE, USE (2)ROWS OF NAILS EA. STRAP
PROVIDE 2x4x4'-0" MEMBERNEXT TO TRUSS AT CONDITIONB & NAIL TO TRUSS w/ 16d @4"o.c. STAGGERED & FORCONDITION C & D USE DBL.TRUSS w/ NAILS @ 4"o.c.
DRAG TRUSS w/ LINE OF E.N.
ROOF SHEATHING
1'-1 3/16"1'-3 1/16"
TYP. TRUSSESBEARING ON WALL
TYP. TRUSSESHANGING
GIRDER TRUSS OR BEAMOFFSET FROM CORNER
SIMPSON STRAPPER SCHEDULE
BEVELED BLK'G
1'-3 1/16"
1 1/2"
ROOF SHEATHING
TYPICALTRUSSES BEARINGON WALL
BEVELED BLKG.w/ E.N. . IF NOT BEVELED,SEE 13/ GD
BEVELED BLK'G
SIMPSON STRAPPER SCHEDULE
GIRDER TRUSS OR BEAMOFFSET FROM CORNERTYP. TRUSSES
BEARING ON WALL
BEVELED BLKG.w/ E.N. IF NOT BEVELED,SEE 13/ GD
NOTES:1. IF DRAG TRUSS IS A JACK TRUSS, PROVIDE PLYWOOD TYPE 2 FROM TOP TO BOTT. CHORD.2. USE DBL. BLKG. FOR CONDITION B, C & D3. REFER TO 17/GD FOR CS16 NAILING PATTERN. * APPLY ONLY AT TRUSS IN LINE CONDITION. ** NAIL LATERAL VALUES BASED ON SPF/HF.
TYP. TRUSSESHANGING FROMGIRDER TRUSS OR BEAM
7
EQ. EQ.
SHIM ASREQUIRED
NON-LAP CHANNELCONDITION
NOTE: FULLY NAIL STRAP w/ 16d - SINKER OR 10d COMMON NAILS SHALL BE STAGGERED & AT LEAST 2 1/4" APART.
NAIL SPLICE
PLATE SPLICE ATSLOPING CONDITION
STRAP SPLICE
ST22 STRAPNUMBER OF NAILS SPECIFIEDBETWEEN SPLICING POINTS PERTABLE BELOW
SIMPSON STRAPPER TABLE BELOW
TYPICAL STUD@ 16"o.c.
16d @ 8"o.c.
2x STUD
CONT. LOWERPLATE @ WALL
EXT. WALLPROVIDE STUDTO RECEIVESTRAP NAILS
NO. OF 16d SINKERMIN. PLATE LAP
ALT. STRAP w/ 16d SINKER ST22 ST6224 ST6236 MST37 MSTC52 CMST12x72"8 FT.
42GF
368 FT.8 FT.
32ED
246 FT.6 FT.
22CB
164 FT.
10A
4 FT.MST60
2x STUD
TYPICAL SPLICE TOP PLATE
CONDITION B w/PLYWOOD OUTSIDE
ALTERNATECONNECTION
ALTERNATECONNECTION
CONDITION Aw/ PLYWD INSIDE
NOTES: 1. AT CONDITION B LOCATE SIMPSON H2.5 PRIOR TO INSTALLATION OF 2X BLK'G.
H2.5 @ 48"o.c. FROMLEDGER TO STUDS.SLIT THE PLYWOODTO INSTALL H2.5
2x STUD OR BM.PER PLAN
E.N.
2x BLOCKING
E.N.
2x BEVELED LEDGER w/(4)16dPER STUD U.N.O. (IF NOTBEVELED, SEE DETAIL 13/GD)
ROOF SHEATHING
16d @ 6"o.c. U.N.O.
2x R/R OR TOPCHORD OF TRUSS
MIN. (3)16d TOE NAILSTO LEDGER. IF SPANOF ROOF MEMBER ISMORE THAN 8'-0", USEJOIST HANGER
ROOF SHEATHINGE.N.
16d @ 6"o.c. U.N.O.
H2.5 @ 48"o.c. FROMLEDGER TO STUDS.SLIT THE PLYWOODTO INSTALL H2.5
2x STUD OR BM.PER PLAN
EDGE NAILING
2x BLOCKING
FULL HEIGHT SHEAR PANEL WHEREOCCURS. WHEN OUTSIDE, TO BEINSTALLEDPRIOR TO ROOF FRAMING.IF SHEAR PANEL IS NOTCALLOUT ONPLAN. INSTALL SHEAR PANEL PER NOTE 7
FULL HEIGHT SHEAR PANEL WHEREOCCURS. WHEN OUTSIDE, TO BEINSTALLEDPRIOR TO ROOF FRAMING.IF SHEAR PANEL IS NOTCALLOUT ONPLAN. INSTALL SHEAR PANEL PER NOTE 7
2x BLOCKING
H2.5 @ 48"o.c. FROMLEDGER TO STUDS.SLIT THE PLYWOODTO INSTALL H2.5
16d @ 6"o.c. U.N.O.
2x STUD OR BM.PER PLAN
8d COMMON @ 4"o.c.(U.N.O.) PER SHEARWALL SCHEDULE
PLYWOOD SHEAR PANEL TYPE 2ENTIRE WALL FROM LOW ROOFTO HIGH ROOF U.N.O.
E.N.2x BEVELED LEDGER w/(4)16dPER STUD U.N.O. (IF NOTBEVELED, SEE DETAIL 13/GD)
MIN. (3)16d TOE NAILSTO LEDGER. IF SPANOF ROOF MEMBER ISMORE THAN 8'-0", USEJOIST HANGER
ROOF SHEATHING
2x R/R OR TOPCHORD OF TRUSS
PLYWOOD SHEAR PANEL TYPE 2ENTIRE WALL FROM LOW ROOFTO HIGH ROOF U.N.O.
ROOF SHEATHING
2x R/R OR TOPCHORD OF TRUSS
E.N.
PLYWOOD WHERE OCCURSPER PLAN. APPLY PRIOR TOLOW ROOF INSTALLATION
2x BLOCKING
H2.5 @ 48"o.c. FROMLEDGER TO STUDS.SLIT THE PLYWOODTO INSTALL H2.5
16d @ 6"o.c. U.N.O.
2x STUD OR BM.PER PLAN
8d COMMON @ 4"o.c.(U.N.O.) PER SHEARWALL SCHEDULE
HIGH TO LOW ROOF
8
9
10
ALT. CONDITION
LINE OF BLK'G. INSTALLEDBY TRUSS MANUFACTURER& TO TRANSFER 250 PLF TOTOP CHORD OF GIRDER.IF GIRDER TRUSS IS NOTDESIGNED TO TRANSFERLOAD, APPLY PLWD. TYPE 2
2x BEVELED BLK'G.OR 2x CONT. NAILERw/ 16d @ 6"o.c. IFNOT BEVELED,SEE DETAIL 13-GD
ALT. LOCATIONOF PLYWOODTYPE 2
2x FLAT BLK'G
2x CONT. NAILEROR TOP CHORD OFTRUSS w/ 16d @ 6"o.c.
E.N.
TYPICALH2.5 @ 48"o.c.
ROOF SHEATHING
ROOF SHEATHING
TYP. TRUSSESPER TRUSSMANUFACTURER
SHEAR/ GIRDERTRUSS DESIGNEDBY TRUSS ENGINEER
2x BEVELED BLK'G.w/ 16d @ 6"o.c. IFNOT BEVELED,SEE DETAIL 13-GD
TYPICALH2.5 @ 48"o.c.
TRUSS/ JACK TRUSSESw/ APPROVED HANGERBY TRUSS MANUFACTURER
E.N.
SHEAR TRANSFER
A-A
ALT. CONDITION
USE SAME SHEARTYPE AS BELOW
CALIFORNIAFRAMING
GIRDER TRUSS/SHEAR TRUSSWHERE OCCURS
E.N.
16d @ 4"o.c.STAGGERED
SHEAR PANELPER PLAN
ROOF TRUSS
2x BEVELEDBLK'G. IF BLK'G.IS NOT BEVELED,SEE 13/ GD
2x BEVELED BLK'G.IF BLK'G. IS NOT BEVELED,SEE 13/ GD
2x BLK'G. w/ A35 @ 8"o.c.OMIT A35's IF PLYWOODIS CONTINUOUS TOUPPER BLK'GA35, SPACING
PER SHEAR WALLSCHEDULE (ATNON-SHEAR WALL,@ 48"o.c. MAX.)
CALIFORNIAFRAMING
ROOF TRUSS
2x BEVELED BLK'G.IF BLK'G. IS NOTBEVELED, SEE 13/GD
A35, SPACINGPER SHEAR WALLSCHEDULE (ATNON-SHEAR WALL,@ 48"o.c. MAX.)SHEAR PANEL
PER PLAN
16d @ 4"o.c.STAGGERED
GIRDER TRUSS/ SHEARTRUSS WHERE OCCURS
E.N.ROOF SHEATHING
E.N.
ROOF SHEATHING
SHEAR TRANSFER
ADD 2"x4"x48" LONGMEMBER TO RECEIVE 2ND.CS16 & NAIL w/ 16d @ 4"o.c.STAGGERED TO ROOFRAFTER/ TRUSS TOP CHORD
REFER TO 17/ GD FORCS16 NAILING PATTERN
NAIL LATERAL VALUES BASEDON SPF/ HF
ASTRAP CAPACITY** END LENGTH
CS16 1700# 3'-6"B (2)CS16 3400# 3'-6"
END LENGHT
SIMPSON CS16 w/(2)ROWS OF 8d SINKERNAILS @ 4 1/8"o.c.CUT TO FIT OVER ALL BAYS OF BLOCKING.WHERE APPLICABLE
(2) TOPPLATE OR BEAM
TYPICAL ROOF RAFTER OR TOPCHORD OF TRUSS
ROOF SHEATHINGw/ E.N. ALONG LINEOF DRAG
**
***
DRAG DETAIL
E.N.ROOF SHEATHING
OVERFILLRAFTERS
ROOFSHEATHING
E.N.SHEAR/GIRDER TRUSSPER MANUFACTURER MANUFACTURED TRUSS
w/ APPROVED HANGER2x BLK'G. w/ 16d SINKER NAILSAT 6"o.c. SEE DETAIL 13/GDFOR NON- BEVELED BLOCK
MANUFACTURED TRUSSw/ APPROVED HANGER
2x BLK'G. w/ 16d SINKER NAILSAT 6"o.c. SEE DETAIL 13/GDFOR NON- BEVELED BLOCK
LINE OF BLK'G. INSTALLEDBY TRUSS MANUFACTURERAND TO TRANSFER 250 PLFTO TOP CHORD. IF GIRDERTRUSS IS NOT DESIGNED TOTRANSFER THIS LOAD, APPLYSHEAR PANEL TYPE 2
E.N. ROOFSHEATHING
SHEAR/GIRDER TRUSSPER MANUFACTURER
SHEAR TRANSFER 11
12
13
14
(2)2x TOP PL
SHEAR PANELTYPE PER PLANB.N. AT BLK'G &EDGES OFSHEAR WALL
2x STUD PER PLAN
CONT. STUDS / POSTw/ B.N. & HOLDOWNPER PLAN
NAILING / SCREWS/ BOLT PER PLAN
2x STUDPER PLAN
CONT. STUDS/POST w/ B.N.& HOLDOWNPER PLAN
CS16 OVER 2x BLK'Gw/ 8d @ 2 1/16" o.c.TYP. EA. CORNEROF OPENING
(2) ROWS 16dSINKER NAIL STAGG.PER SCHED. ABV.
(2) ROWS 16dSINKER NAIL STAGG.PER SCHED. ABV.
CS16 OVER 2x BLK'Gw/ 8d @ 2 1/16"o.c.TYP. EA. CORNEROF OPENING
NOTES:1. INSTALL HOLDOWN ON RETURN WALL AT CORNERS WHEN APPLICABLE.2. USE FULL WIDTH BLK'G. & WINDOW SILL FOR STRAP ON BOTH SIDES OF (2) SIDED SHEAR PANELS.3. NAIL BOTH PLWD. PANELS ON SAME MEMBER.4. REFER TO 17/GD FOR CS16.
HEADERPER PLAN
WINDOW SILLWHERE OCCURS
OPEN AT SHEAR WALL
1'-6"
CS16 OVER 2x BLK'Gw/ 8d @ 2 1/16"o.c.TYP. EA. CORNEROF OPENING
CONT. STUDS / POSTw/ B.N. & HOLDOWNPER PLAN
CS16 OVER 2x BLK'Gw/ 8d @ 2 1/16"o.c.TYP. EA. CORNEROF OPENING
SHEAR PANEL TYPEPER PLAN B.N.AT BLK'G & EDGESOF SHEAR WALL
HEADER PER PLAN
WINDOW SILLWHERE OCCURS
CS16 OVER 2x BLK'Gw/ 8d @ 2 1/16"o.c.TYP. EA. CORNEROF OPENINGCONT. STUDS / POSTw/ B.N. & HOLDOWNPER PLAN
HEADERPER PLAN SHEAR PANEL
TYPE PER PLANB.N. AT BLK'G &EDGES OFSHEAR WALL
(2)2x TOP PL
1/8"
A-A
PANEL EDGE
PANEL TYPES NAIL SPACING
@ 12" O.C.2
@ 9" O.C.3
@ 6" O.C.4
@ 5" O.C.5
@ 4" O.C.3DBL SIDED
4DBL SIDED
5DBL SIDED
@ 3" O.C.
@ 2 1/2" O.C.
CONDITION A
CONDITION B
CONDITION C
DRAG DETAIL
CS16 STRAPEND LENGTHEND LENGTH
END LENGTH
END LENGTH
2x BLOCKINGON EDGE
TRUSSES
NOTES:1. REFER TO 17/GD FOR CS16 NAILING PATTERN.2. STRAP TO EXTEND ON ALL BLKG. (MIN. (3) BAYS).3. USE DOUBLE BLOCKING OR FLAT BLOCKS FOR CONDITION B.4. USE SINKER AT STRAPS. * NAIL LATERAL VALUES BASED ON SPF/HF.
END LENGTHSTRAPCS16
(2) CS16AB 3'-6"
3'-6" (2) ROWS 8d @ 4 1/8"(2) ROWS 8d @ 4 1/2" 3400#
1700#CAPACITY*NAIL SIZE & SPACING
SHEAR PANELPER PLAN
4x6 POSTMIN. AS SHOWN
ALT. LOCATIONOF SHEAR PANEL
PLAN VIEW"D""B"
"A" "C"
2x4 STUD
SHEAR PANELPER PLAN
16d @ 3"o.c.STAGGERRED1/4"ø x4"SDS @ 4"o.c.FOR TYPE 5
B.N.
B.N.
CONNECTION DETAILS
15
16
17
SIMPSON STRAPPER TABLE(2) ROWS OF NAILSFOR EA. STRAP
SPACINGAND LENGTHSEE TABLE
SIMILAR CONDITION(FLUSH BEAM/ JOIST (S)) CONT. BEAM OR BLK'G
SEE FRAMING PLAN
(2) TOP PL
POST OR MULTISTUDSEE PLANBEAM OR JOIST
w/ LINE OF EDGENAILING SEE PLAN
CAPACITY1700#3400#4585#6490#10d BOX AT 3 1/2"
10d BOX AT 4 1/2"8d BOX/SINKER AT 4 1/8"8d BOX/SINKER AT 4 1/8"NAIL SIZE AND SPACINGEND LENGTH
3'-0"3'-0"6'-0"6'-3"CMST14
CMSTC16(2) CS16
CS16STRAP
DCB*A
NOTES:1. MIN. 3 1/2" WIDE MEMBER FOR CONDITION C &D.2. REFER TO 17/GD FOR CS16 NAILING PATTERN. MIN. 1/2" SPACING BETWEEN ROWS OF NAILS.*
DRAG DETAIL
PROJECT NAME:
ARCHITECT:
DEVELOPER:
ADDRESS:
PLOT DATE:
DESIGNED BY:
SHEET NAME:
SHEET NUMBER:
PROJECT NUMBER:
DESCRIPTIONDATENO.
REVISIONS
aBPa
RMO Greenfield Estates
M&O Investments
EL CAJON, CA
INGAMAC WAY
50011
04/13/2015
CHECKED BY:
BLDG. DEPT.03/31/20151
SD-2
STRUCTRUAL
DETAILS
H.M. A.D.
1
2
3
4
5
6
7
8
9
10
11
12
14
15
HOLDOWN DETAIL
* CMST14 & CMST12 ARE ONLY APPLICABLE AT POST TO POST CONNECTION.** AS AN ALT. TO B & C, USE D FOR POST TO POST CONDITION ONLY.
STRAP
(1)CS16(2)CS16 **(2)CS14 **(3)CS14CMST14CMST12(2)CMST14(2)CMST12
ABCC*DEFG
STUD/ POST
2X4(2)2X4(2)2X4
4X64X44X64X86X8
# OF NAILS @ EA. END LENGTH
(11)16d(11)16d P/STRAP(15)16d P/STRAP
(40)16d(15)16d P/STRAP
(52)16d(40)16d P/STRAP(52)16d P/STRAP
CAPACITY
1700#3400#4980#7470#6490#9200#12980#18400#
END LENGTH
13"13"18"18"38"48"38"48"
MIN. 11 1/4" DEEP BM.OR HEADER. SEE PLAN.
MIN. 11 1/4" DEEP BM.OR HEADER. SEE PLAN.
STUD, POST OR TRIMMER PER TABLE BELOW. DBL.STUDS & STRAPS @ CONDITION "B"&"C" PROVIDEEDGE NAILING OF SHEAR PANEL ALONG ALL STUDS.
REFER TO PLANS & TABLE BELOW FORSTRAP, # OF NAILS & END LENGTH ATEA. END. (2) ROWS OF NAILS EA. STRAP.
DOUBLE TOP PLATE.
PROVIDE MIN. END DISTANCEOF 1 5/8" FOR 16d NAILS.
SOLID RIM OR BLKG. SAME WIDTH AS POSTABV. & BLW. @ LOCATION OF STRAP. WHENW/FLOOR. TRUSS, PROVIDE WEB FILLERS ASNEEDED TO RECEIVE NAILING FROM STRAP.
SEE PLAN FORSHEAR WALL.
FLOOR SHTG. SEE PLAN.
STUD, POST OR TRIMMER PER TABLEBELOW. DBL. STUDS & STRAPS @CONDITION "B"&"C" PROVIDE EDGE NAILINGOF SHEAR PANEL ALONG ALL STUDS.
REFER TO PLANS & TABLE BELOW FORSTRAP, # OF NAILS & END LENGTH ATEA. END. (2) ROWS OF NAILS EA. STRAP.
LINE OF BLKG. UNDER SHEAR WALL.
2X SILL PLATE.
SOLID BLKG. UNDER POST OR STUDSABOVE.
DOUBLE TOP PLATE.
CRIPPLE WALL ABOVE HDR.WHERE OCCURS.
STUD, POST OR TRIMMER PER TABLEBELOW.DBL. STUDS & STRAPS @ CONDITION"B"&"C"PROVIDE EDGE NAILING OF SHEAR PANELALONG ALL STUDS.
REFER TO PLANS & TABLE BELOW FORSTRAP, # OF NAILS & END LENGTH AT EA.END. (2) ROWS OF NAILS EA. STRAP.
LINE OF BLKG. UNDERSHEAR WALL.
FLOOR SHTG. SEE PLAN.
2X SILL PLATE.
STUD, POST OR TRIMMER PER TABLE BELOW. DBL.STUDS & STRAPS @ CONDITION "B"&"C" PROVIDEEDGE NAILING OF SHEAR PANEL ALONG ALL STUDS.
NOTES: 1. ALL STRAPS ARE SIMPSON STRONG TIES. 2. TOTAL LENGTH OF STRAP TO BE DETERMINED @ THE SITE BASED ON END LENGTH REQUIRED & CLEAR SPAN. 3. ALL NAILS ARE SINKER OR BOX NAILS. 4. SLIT CUT FLOOR SHEATHING TO RUN STRAP THROUGH @ INTERIOR CONDITION NO OVERCUT. 5. LOCATE STRAP OVER PLWD. SHEAR PANEL & PROVIDE SHIM AN NECESSARY TO AVOID BENDING OF THE STRAP.
4"
APPLICATION OF CS16's
APLICATION OF MTS & HTS
DBL. TOP PLOR DROP BM.PER PLAN
MULTI STUDOR POST
MULTI STUDOR POST
STRAP TYPESEE TABLE
FLUSH BM/HDR PER PLANSEE DETAIL 5/SD2 FORCONNECTION OF BM/HDRTO POST (U.N.O.)
2X STUDw/16d @ 6"o.c.
NOTES:1. USE 10d SINKER FOR MTS12; USE 10d COMMON NAILS FOR HTS20; USE 8d SINKER NAILS FOR CS16's.2. CUT CS STRAP TO MEET MIN. END LENGTH & USE MIN. (16) 8d's @ EACH END OF EACH STRAP.3. PROVIDE 1 1/2" SPACING BTWN ROWS OF NAILS @ MULTIPLE CS STRAPS.4. REFER TO 17/GD FOR CS16 NAILING PATTERN.
MIN. 4X8 SOLID BLOCKING.
FOR (2) MTS12 USE (2) ST12FOR (2) HTS20 USE (2) ST2122FOR (4) HTS20 USE (2) ST6224
FLUSH BM/HDR PER PLANSEE DETAIL 5/SD2 FORCONNECTION OF BM/HDRTO POST (U.N.O.)
FLUSH BM/HDRPER PLAN SEEDET.5/SD2 FORCONNECTIONOF BM/HDRTO POST (U.N.O.)
18" FOR SAWN LUMBERw/ SPACING @ 2 1/16";3'-6" FOR MFG'R. PRODUCTw/ SPACING @ 4 1/8"o.c.
ALT. CAPACITYSTRAP TYPE1705#2666#(2) HTS20
(2) MTS12(1) CS16 ON 2X4(2) CS16 ON 2-2X4B
A
C (3) CS16 ON 4X6 5115#(4) HTS20
HOLDOWN DETAIL
CONNECTION DETAIL
POST w/SIMPSONCCQ OR CC,SEE PLAN
NOTES: 1. ALIGN BEAMS TO RECEIVE STRAP. 2. ALT. LOCATION OF STRAP ON TOP OF BEAMS.
SIMPSON ST6236
PROVIDE SHIM UNDER AND@ THE SIDE OF THESMALLER BEAM AS REQUIRED
POST w/SIMPSONECCQ ORECC, SEE PLAN
SIMPSON ST6236
POST w/ SIMPSON CCQ OR CC, SEE PLAN
SIMPSON A34
(5)16d EACHSIDE TO BM
ALT. LOCATION OFSTRAP ACROSS SIDEOF TOP PLATE
EQ. EQ.
DBL. TOP PLATE w/ SIMPSONST6236. IF DBL. TOP PLATE ISCONT., ELIMINATE STRAP
MULTI-STUD ORPOST, SEE PLAN
ST6236 STRAP
LINE OF BLK'G. TORECEIVE STRAP
2x STUD ATEACH SIDEw/ 16d AT12"o.c.STAGGERED 2x STUD AT EACH
SIDE w/ 16d AT12"o.c. STAGGERED
SIMPSON A34
FLUSH BEAM
SILL PLATE
2x STUD AT EACHSIDE w/ 16d AT12"o.c. STAGGERED
LINE OF BLK'G. TORECEIVE STRAP
NOTES:1. ADD FILLER @ SIDE OF BEAM AS NEEDED.2. FOR PARTIAL FLUSH BEAM SIMILAR CONDITION. USE (1) A34 EACH SIDE.
DBL. TOP PLATE w/SIMPSON ST6236.IF DBL. TOPPLATE IS CONT.,ELIMINATE STRAP BEAM, SEE PLAN
FOR SIZE
2x STUDS @16"o.c. U.N.O.
BEAM DETAIL
DRAG DETAIL
END LENGTH
END LENGTH
PLYWOOD SHEATHINGw/ E.N. ALONG LINEOF BLOCKING.
TYPICAL JOIST PER PLAN
LINE OF SOLID / MIN 1 3/4" WIDE FULL HT.BLKG PER PLAN FOR NUMBER OF BAYS(MIN. 4 BAYS).
PLYWOOD SHEATHINGw/ E.N. ALONG LINEOF BLOCKING.
TYPICAL JOISTPER PLAN
2x TOP PL OR BM. USE DBL. BLKG.FOR CONDITION B & C. REFER TO17/GD FOR CS16 NAILING PATTERN.TJI BLKG(S) CAN BE USED WHENSTRAP IS APPLIED ON THE TOP.
SIMPSON STRAP PER TABLE BELOW & ATALL BAYS OF BLKG MIN. (3) NAILS PERBLKG.(2) ROWS OF NAILS EA. STRAP.
USE MIN. 2x FULL HT. BLKG w/ LS50/LTP4 IFTHE INSTALLATION OF A35 IS IN CONFLICTWITH THE STEEL STRAP ON TOP PL.NOTE:
NAIL LATERAL VALUES BASED ON SPF/HFNAIL SIZE AND SPACING CAPACITY*STRAP
1700#3400#8d BOX/SINKER AT 4 1/8"
8d BOX/SINKER AT 4 1/8"CS16(2)CS16B
A
C CMSCTC16 4585#16d SINKER AT 4 1/2"
END LENGTH3'-0"3'-0"6'-0"
DRAG BEAM TO WALL DETAIL
2x BLK'G W/ LINEOF EDGE NAILINGALONG DRAG LINEMINIMUM (4) BAYS U.N.O.
STUD OR POSTPER PLANBEAM OR
(2) TOP PLATE.
SIMPSON CS16w/ 8d SINKER NAILSAT 2 1/16"o.c.
CL
NOTES:1. USE 2X FLAT BLOCKING FOR CONDITION "B" W/ MIN. 1 1/2" SPACE BETWEEN ROWS OF NAILS.2. LOCATE STRAP OVER PLWD. SHEAR PANEL SEE PLAN FOR TYPE & LOCATION.3. REFER TO 17/GD FOR CS16 NAILING PATTERN.
END LENGTH
CAPACITY END LENGTHSTRAP3'-0"3'-0"3400#
1700#(1)CS16 (2)CS16B
A
ALT. TRUSS
3/4"1 1/2"
3/4"
3/4"
SHEAR TRANSFER
B.N.
B.N.
B.N.
FLOOR SHEATHING
FLOORSHEATHING
8d or 10dB.N. 2x TIMBER STRAND
OR L.V.L. RIMPER PLAN
16d @ 16"o.c.
BLK'G SEE 6/GD
2x TIMBER STRANDOR L.V.L. RIMPER PLAN
SIMPSON A35/LPT4PER SCHEDULE
SHEAR PANELPER PLAN
STUD WALLWHERE OCCURS
ALT. INTERIOR CONDITION ONLY
EXTERIOR CONDITION AND ATEDGE OF FLOOR DIAPHRAGM
STUD WALLWHERE OCCURS
PROVIDE 2x NAILER
FLOOR SYSTEMPER PLAN
SIMPSON A35/LPT4PER SCHEDULE
SIMPSON A35/LPT4PER SCHEDULE
SOLID BLK'G
INTERIOR COND. & ALT.TO EXTERIOR CONDITION
ALT. LOCATION FOR LTP4 ONLYALT. " I-JOIST"CONDITION
STAGG. SILLPLATE NAILINGPER SCHEDULE
TJI-230 OREQUIVALENT w/ 2 5/16"WIDE FLANGE
10d
ALT. LOCATIONOF A35
LS50 @ EACH CORNER
LS50 FROM POST/MULTI STUD TO HDR. TOP & BOTTOM. ALT.(1) EACH FACE
(2) 2X TOP PLATE.
HEADER PER PLAN EXTEND TO POST.
FULL HT. POSTORMULTI STUD PERPLAN.
APPLY ST6236 IFWIDTH OFOPENINGEXCEEDS 6'-0" &IF THERE IS NOTRIMMER.
OPENING PERARCHITECT.
2x TRIMMER w/ 16d @ 8" O.C.TO POST.IF THERE IS NO ROOMFOR TRIMMER, USE HUC (U.N.O.)HANGER TO CONNECT HDR. TOFULL HEIGHT POST & USE ST6236TO CONNECT HDRS TOGETHER.CENTER STRAP @ POST.
2X WINDOW SILLTYPICAL.
2X SILL PLATETYPICAL (U.N.O.).
FULL HT. POSTOR MULTI STUDPER PLAN.
LS50 @ EACHCORNER
LS50 @ EACHCORNER
HEADER PERPLAN EXTENDTO POST.
TYP. 2X FLOAT@ EDGE OFOPENING.
ALT. LOCATIONOF LTP4 (1)EACH FACEOF EACH HDRTO POST.
2X WINDOWSILL TYPICAL.
NOTE:USE APPROVED HANGER TO CONNECT HDR. TO POST IF THERE IS NO ROOM FOR TRIMMER.
WALL ELEVATION @ OPENING
HANDRAIL/GUARD RAIL-ONE & TWO FAMILY
1"1"
BB
1"1"
STRINGERPER DET10/SD3
4x4 MIN.(D.F.#2)NEWEL POST
PLYWOODTREADS
1/4"ø x5"LAG SCREWS
BB
NEWEL POST AT STRINGER
1/4"ø x5"LAG SCREWS
PLAN VIEW B-B
INFILL BLK'G BETWEENNEWEL POSTS
3 1/4"MIN.
(3)10dNAILS
(2)2x4FLATBLOCKING
1/4"ø x5"LAG SCREWS
SECTION C-C
(2) H2.5APERIMETER
4x4 MIN.(D.F.#2)NEWEL POST
INFILL BLK'GBETWEENNEWEL POSTS
4x4 MIN.(D.F.#2)NEWEL POST
PERIMETER BEAM/RIMJOIST PER PLAN
FLR. JOISTw/ B.N. ALONGJOIST LENGTH
4x4 w/(9)16d NAILS@ T&B OF FLOOR JOIST
(2)2x STUDS/4x4 POST @4'-0"o.c. MAX.
4x4 BLK'G@ 4'-0"o.c.MAX.w/(6)16d NAILSATEA END
ø7/16" x4"LONG LAGSCREW WITHWASHER @48"o.c. MAX.
HANDRAILBRACKETPERMANUF.
BALUSTER PER ARCH'L'SDETAIL CONN. BY OTHERS
AA
CS18 WRAP & 4x4 ADD-ONw/(2) ROWS OF 10d NAILS@ 2 1/16"o.c. MIN. 16" ENDLENGTH
4x4 w/(9)16d NAILS@ T&BOF FLOORJOIST
FLR. JOIST w/B.N. ALONGJOIST LENGTH
11/16" MIN.
11/16" MIN.
26" MIN.
16"
PERIMETER BEAM/RIM JOIST PER PLAN
INFILLBLK'GBETWEENNEWELPOSTS
A35 BOTH FACESOF NEWEL POSTTO PERIMETER BM.
(2)H2.5AT&BNEWELPOSTTO BM.
ALTERATIVECONDITION
(2)2x PLw/(2) ROWSOF 10dNAILS @12"o.c.STAGG.
(2)16d T.N.EA. SIDE OF(2) STUDS T&B
(2)2x TUDS/4x4 POST@ 4'-0"o.c.MAX.
(2)16d T.N.EA. SIDEOF (2)STUDS T&B(2)16d S.N.EA. SIDEOF (2) STUDS(4) TOTAL
(2)ST18 BOTHEDGES OFSTUDS/4x4(4) TOTAL.NAILS ALLHOLES w/16d NAILS
2x ADD-ONw/(2) ROWSOF 10d F.N.@ 8"o.c. TOFLOOR JOISTADJ. TO(2)2x4 STUDS
4x NOMINAL(MIN.) FULLDEPTH LP.M.ALT. (2) RIMJOISTSw/ PLYWOODSHIMIN BETWEEN
DRAG DETAIL
END LENGTH END LENGTH
PER TABLE
DRAG STRUTw/ E.N.PER PLANSIF NOT CONT.SPLICE PERTABLE BELOW
PLYWOODSHEATHINGw/ E.N.
STRAP PER TABLE BELOWAPPLY STRAP ON TOP OFSHEATHING AS AN ALT.
BEAM PER PLAN
NOTE:1. WHERE STRAP IS APPLIED ON TOP OF SHEATHING ELIMINATE LINE OF E.N. ALONG LENGTH OF STRAP ONLY2. MIN. 3 1/2" WIDE MEMBER FOR CONDITION C & D3. MIN. 1 1/2" SPACING BETWEEN ROWS OF NAILS. ADD 2x6xSTRAP LENGTH NEXT TO DRAG ELEMENT TO RECEIVE 2ND. STRAP, NAIL w/ 16d @ 4"o.c. STAGGERED.4. REFER TO 17/GD FOR CS16 NAILING PATTERN.
STRAP END LENGTH NAIL SIZE AND SPACING CAPACITY*AB*C
CS16(2)CS16
CMSCTC16
3'-0"3'-0"6'-0"
8d BOX/SINKER AT 4 1/8"8d BOX/SINKER AT 4 1/8"
10d BOX AT 4 1/2"
1700#3400#4585#
6'-3" 10d BOX AT 4 1/2" 6490#D CMST14
SHEAR TRANSFER
E.N.E.N.
FLOORSHEATHING
SHEAR PANELPER PLAN
2x STUD WALL
2x SILL PLATEw/ NAILSPER PLAN
E.N.
SHEAR PANELPER PLAN
2x CONT.TIMBER STRANDOR LVL
FLOORSYSTEM
E.N.@ 3"o.c. MAX.
SIMPSON A35@ RIM JOIST
2x MEMBER,1 1/4" TIMBER STRANDOR I-JOIST PER PLAN
ALT. CONNECTION
INVENTED IUTHANGER @EVERY JOIST
CONN. @ FLOOR CHANGE/DECKCANT. DECK
MAX. 8'-0"
MAX. 4'-0"
MAX. 8'-0"
PLYWOODSHEATHING.
BM. OR RIMJOIST PER PLANAND PER DETAIL 7/SD3.
E.N. TYP.
FLUSH/DROP BEAMOR WALL PER PLAN.
SEE ALT. DECKING BELOW.
FLOOR SYSTEMPER PLANS.
WALL OR BM.WHERE OCCURS.
SUPPORT RIM JOISTFROM CANT. FLOORJOIST W/ FULL HT.INVERTED "HU" HANGER.
2x BLOCKING PERDETAIL 7/SD3
WALL OR BM.WHERE OCCURS.
2x BLOCKING PERDETAIL 7/SD3
DECK w/SLOPE TODRAIN OR FLOOR JOISTPER PLAN w/ APPROVEDJOIST HANGER.
2X LEDGER w/(2)ROWS OF 1/4" SDS x 3"SCREWS @ 12"o.c.
FLUSH/DROPBEAM OR WALLPER PLAN.
DECK w/SLOPE TODRAIN OR FLOOR JOISTPER PLAN w/ APPROVEDJOIST HANGER.
DECK w/SLOPE TODRAIN OR FLOOR JOISTPER PLAN w/ APPROVEDJOIST HANGER.
NOTE: USE PLYWOOD FILLER @ I-JOIST TO RECEIVE HANGER OR OTHER MEMBERS.
2X4 BLOCKINGw/ 16d's @ 4" o.c.
PLYWOOD SHEATHING.
SEE ALT.DECKING BELOW.
SEE ALT.DECKING BELOW.
ROOF TO FLOOR SHEAR TRANSFER
ALT. CONDITION
ALT. CONDITIONFLOOR BEAMPER PLAN
FLR. SHEATHING& FLOOR SYSTEM
EDGE NAILING
2x BLOCKING
16d @ 6"o.c.(U.N.O.)
CONT.2x BEVELEDLEDGER w/(4)16dPER STUD U.N.O.(IF NOT BEVELED,SEE DETAIL 13/GD)FOR SPLICING OFLEDGER (IF NEEDED)USE (1) CS16x24" LONGCENTERED @ SPLICE.SEE 17/GD FOR NAILPATTERN
H2.5 @ 48"o.c.FROM LEDGERTO STUDS
TRUSS BOTT. CHORDw/ END WEB WHERE OCCURS
16d @ 6"o.c. (U.N.O.)
SHEAR TRUSS ORTRUSS PANEL BLOCKSTO TRANSFER 380 PLF.CAN BE USED ASALTERNATE TOPLYWOOD TYPE 2
PLYWOOD TYPE2 ENTIRE LENGTHOF WALL U.N.O.
ROOFSHEATHING
FOR ALT. CONNECTIONSSEE DETAIL 10/SD2CONDITION B
ROOF SYSTEMCAN BE PARALLELOR PERPENDICULARTO WALL
PLYWOOD SHEAR WALLPER PLAN HERE OCCURSAPPLY PRIOR TO LOWROOF INSTALLATION
E.N.
PLYWOOD SHEARWALL PER PLANWHERE OCCURSAPPLY PRIORTO LOW ROOFINSTALLATION
2x BEVELED BLK'GAS SHOWN. SEE13/GD FOR NON-BEVELED BLOCK
PLYWOOD SHEARWALL PER PLANWHERE OCCURSAPPLY PRIOR TOLOW ROOFINSTALLATION
16d @ 6"o.c.(U.N.O.)
TRUSS HANGERPER TRUSSMANUFACTURER
STAIR DETAILS
STRINGERS @ 16"o.c.(2)2x16 @ INTERIOR2x16 @ EDGE
MAX.SPAN
18'-0"
12'-0"10'-0"8'-0" 2x12 ALL
2x14 ALL2x16 ALL
PERARCH'L
2x4 P.T. PLATE (SEEGN) ANCHORED WITHSIMP. PHNW-72 SHOTPINS 0.145ø w/ 3/4" MIN.EMBED INTO CONC@ 24"o.c. MAX. SECURESTRINGER TO 2x4 PLATEw/(3)16d TOE NAILS
PRESSURE TREATEDPLYWOOD SHIM w/ MIN.(2)SIMP. PHNW-72 SHOTPINS 0.145ø w/ 3/4" MIN.EMBED INTO CONCRETE.22GA SHEET METAL ORWATER PROOF MEMBRANTCAN BE USED AS AN ALTERNATE
PLYWOOD TREADS &RISERS (MIN. 3/4")
PLYWOODSUBFLOOR
DBL. JOISTOR BLOCKING
CONT. 2x PLATEw/ 16d @ 8"o.c.
SEE TABLE. SPANSARE HORIZONTALPROJECTION LENGTH.(ALT. LSL STRINGERSOF THE SAME SIZES w/Fb=1700psi (MIN.),Fv=400psi (MIN.), &E=1.3x10 psi (MIN.)CAN BE USED
PLYWOOD TREADS& RISERS (MIN. 3/4")
SIMPSON THA213, ALT.(1)A35 EA. SIDE UP TOMAX. 12'-0" SPAN*. USETHA218/THA218-2FOR 2x16/(2)2x16
2x6 LEDGER w/(4)16d PER STUD@ WALL CONDITION
APPROVED METALHANGERS OR(1)A35 EACH SIDE
SEE TABLE. SPANS ARE HORIZONTALPROJECTION LENGTH. (ALT. LSLSTRINGERS OF THE SAME SIZES w/Fb=1700psi (MIN.),Fv=400psi (MIN.),&E=1.3x10 psi (MIN.) CAN BE USED
DOUBLE JOISTOR HEADER
5 1/4" MIN. FOR 2x12,7 1/4" MIN. FOR 2x14& 9 1/4" FOR 2x16 @NOTCH NO OVERCUT
SHEAR TRANSFER DETAIL
2X STUD WALL SHEAR PANEL PER PLAN
FLOOR SYSTEMPER PLANWHEN NOTCHEDUSE FILLERS
BEAM OR BLK'G.MIN. 1 3/4" WIDEPER PLAN. USEAPPROVED HANGER@ FLUSH BEAMCONDITION
2 X R/R OR JACK TRUSS PER PLAN
LS50 @ 32"o.c.
EDGE NAILING
2X BEVELED BLK'G. w/ E.N.,IF NOT BEVELED, SEE 13/GD
2X BEVELED LEDGER w/(3)16d's TO EACH STUD,IF NOT BEVELED, SEE 13/GD ATTACH LEDGERTO STUDS w/H2.5 AT 48"o.c.
BLK'G/RIM JOIST PER PLAN w/A35's @ 16"o.c. U.N.O. USELS50/LTP4 IF THE INSTALLATIONOF A35 IS IN CONFLICT W/ STEELSTRAP ON TOP PLATES.
PLYWOODSHEATHING2X BLK'G. w/ E.N.
& w/(3)16d's TOBEVELED BLOCK
2X STUD WALL SHEAR PANEL PER PLAN
SHEAR PANELPER PLAN
FLOOR SYSTEMPER PLANWHEN NOTCHEDUSE FILLERS
EDGE NAILING
EDGE NAILING
2X BEVELED BLK'G.w/ E.N., IF NOT BEVELED,SEE 13/GD.BLK'G/RIM JOIST PER PLAN w/A35's @ 16"o.c. U.N.O. USELS50/LTP4 IF THE INSTALLATIONOF A35 IS IN CONFLICT W/ STEELSTRAP ON TOP PLATES.
PLYWOOD SHEATHING
13
SD-3
STRUCTRUAL
DETAILS
H.M. A.D.
PROJECT NAME:
ARCHITECT:
DEVELOPER:
ADDRESS:
PLOT DATE:
DESIGNED BY:
SHEET NAME:
SHEET NUMBER:
PROJECT NUMBER:
DESCRIPTIONDATENO.
REVISIONS
aBPa
RMO Greenfield Estates
M&O Investments
EL CAJON, CA
INGAMAC WAY
50011
04/13/2015
CHECKED BY:
BLDG. DEPT.03/31/20151
1 SD-4
STRUCTRUAL
DETAILS
H.M. A.D.
PROJECT NAME:
ARCHITECT:
DEVELOPER:
ADDRESS:
PLOT DATE:
DESIGNED BY:
SHEET NAME:
SHEET NUMBER:
PROJECT NUMBER:
DESCRIPTIONDATENO.
REVISIONS
aBPa
RMO Greenfield Estates
M&O Investments
EL CAJON, CA
INGAMAC WAY
50011
04/13/2015
CHECKED BY:
BLDG. DEPT.03/31/20151
SHEAR PANEL AT GARAGE
5 1/2"
2 1/16"
PLYWOOD SHEATHING W/ B.N.DOUBLE TOP PLATE. PLYWOOD TYPE U.N.O.(E.N. TO GARAGE DOORHDR & TOP PLATES).ELIMINATE IFHDR. IS FLUSH W/TOP PLATES.
CONT. GARAGEDOOR HDR.(PER PLANS)
SHEAR PANEL, SEE PLANS(E.N. ALONG THE POSTS & THEGARAGE DOOR HDR.
4X6 POST U.N.O.
(1) SIMP. ST6236 E/S OF EACHPOST (2) TOTAL PER POST.OFFSET & CENTERED AT POST& HDR. USE 16d NAILS (FILLALL HOLES) U.N.O.
4X6 POST U.N.O.
SHEAR PANEL, SEE PLANS(E.N. ALONG THE POSTS & THEGARAGE DOOR HDR.
SHEAR PANEL, SEE PLANS(E.N. ALONG THE POSTS & THEGARAGE DOOR HDR.
TOP VIEW OF ITEM #7 & #8.
HOLDOWN WHERE OCCURS.
2X STUD AT 16" O.C.
ARCHITECTURAL PROJECTIONTO BE CONSTRUCTED AFTER COMPLETE SHEAR PANELINSTALLATION
HOLDOWN WHERE OCCURS.
2X KING STUD W/ (6)16d TOGARAGE DOOR HDR. & (1) A35TO TOP/LOWER PLATES APPLYTO RETURN WALL WHEN USING HD.
2X CRIPPLE WHERE OCCURS
(1) SIMP. ST6236 E/S OF EACHPOST (2) TOTAL PER POST.OFFSET & CENTERED AT POST& HDR. USE 16d NAILS (FILLALL HOLES) U.N.O.
MIN. (2) ANCHOR BOLTS,SEE PLANS
2X KING STUD W/ (6)16d TOGARAGE DOOR HDR. & (1) A35TO TOP/LOWER PLATES APPLYTO RETURN WALL WHEN USING HD.
4X6 POST U.N.O.
NOTE: DEEPEN FOOTING ASREQUIRED TO ACHIEVE le+4 &EXTEND le/2 EACH WAY ALONGFOOTING LENGTH FROM HOLDOWN.
SHEAR TRANSFER DETAIL
ROOF SHEATHING EXTENDED& EDGE NAILED TO BLOCKING.
ROOF RAFTERS PER PLAN.
DBL TOP PLATE OR BM. PER PLAN
SHEAR PANEL PER PLAN.
STARTER BOARD WHERE OCCURS.
FULL HEIGHT BLOCKING
EQUALLY SPACED A35's.SEE PLAN FOR TOTALNUMBER REQ. ON WALL LINE.
SHEAR TRANSFER
(2) 16d's PERCONNECTION.
EDGE NAILING.
2X FASCIA BOARD.
ROOF SHEATHING.
TYPICAL ROOFRAFTER PER PLAN.
2X FASCIA BOARD.
(2) 16d's PERCONNECTION.
SHIM AS REQUIRED.
TYPICAL ROOFRAFTER PER PLAN.
2X FLAT BLOCKS W/16d's @ 4" O.C. TOPLATE BELOW. 2X FLAT OUTRIGGER
@ 24" O.C.
(2) 16d's PERCONNECTION.
(2) 16d's PERCONNECTION.
2X FLAT OUTRIGGER@ 24" O.C.
NOTCH RAFTER @OUTRIGGER DONOT OVERCUT.
ALTERNATE COND.W/ ROOF RAFTERNEXT TO WALLW/16 d's @ 8" O.C.TO TOP PLATE.
EDGE NAILING.
2
3
NOTCH - SIDE VIEW
FLUSH BEAM NOTCHEDAS SHOWN.
OVERALL BEAM DEPTH.
DBL. TOP PLATE, BEAMOR POST.
NOTE: DO NOT OVERCUT
MATCH SLOPE OF ROOF
4