FRONT ELEVATION

Click here to load reader

  • date post

    10-Feb-2022
  • Category

    Documents

  • view

    0
  • download

    0

Embed Size (px)

Transcript of FRONT ELEVATION

SAUVIGNON.pdfPrecision Building Design Associates Chilliwack, B.C. (604) 792-0826
-Drawings are subject to change without notice. The developer reserves the to make modifications to the drawings at their sole discretion in accordance with building code guidelines and to maintain the high quality of the homes. -Window sizes are subject to change from site to site based on site limiting distance calculations. -Drawings to be read in conjunction with structural drawings by VanDenBrink Engineering LTD. -These drawings are based on the original drawings and details created by Rositch Hemphill Architects, and have been subsequently modified and/or reformatted by Precision Building Design Associates Ltd.
unit number:
FRONT ELEVATION
REAR ELEVATION These plans are intended for illustration purposes. Detailed working drawings will be provided to subcontractors and suppliers for construction purposes. The developer reserves the right to make changes to the plans and specifications at their discretion. Refer to colour boards for actual exterior colors. E and O E
Lawrence Flagel
Developer’s Floor Plan 136 is Mirrored and Bedroom #3 and #4 are combined into Rec Room
2
2
1
1
BB
C
5060
E N
G D
R O
P B
E A
E N
G F
LU S
H B
E A
5 0
3 6
2' - 0" 32' - 0" 2' - 0"
8' - 2" 15' - 8" 8' - 2"
1' - 3" 4' - 1" 4' - 1" 6" 4' - 6 1/2" 6" 4' - 6 1/2" 6" 4' - 6 1/2" 6" 4' - 1" 4' - 1"
6 5 ' -
1' - 3" 5' - 6" 5' - 6" 10' - 6" 10' - 6"
4 ' -
5 "
1' -
0 "
2 ' -
5 "
8 ' -
4 "
5 ' -
4 "
12 ' -
8 "
6 "
4 ' -
3 "
6 "
4 ' -
3 "
6 "
4 ' -
3 "
1' -
2 "
11' -
6 "
9 "
3 ' -
" 10
' - 8
" 2 ' -
0 "
10 ' -
7 "
2 ' -
4 "
3 ' -
0 "
4 ' -
4 "
2 ' -
2 "
3 ' -
4 "
7' -
0 "
3' - 0" 3' - 5" 2' - 3" 3' - 10" 2' - 4" 3' - 6" 3' - 4"
1' - 3" 4' - 6" 3' - 0" 3' - 9" 5' - 3" 2' - 6" 3' - 10" 2' - 7" 6' - 7"
36" HIGH HALF WALL
2' - 4"
E N
G . F
LU S
H B
E A
3' - 0" 3' - 0" 2' - 4" 3' - 6" 3' - 4"
A C
TI V
unit style: color scheme:
Precision Building Design Associates Chilliwack, B.C. (604) 792-0826
-Drawings are subject to change without notice. The developer reserves the to make modifications to the drawings at their sole discretion in accordance with building code guidelines and to maintain the high quality of the homes. -Window sizes are subject to change from site to site based on site limiting distance calculations. -Drawings to be read in conjunction with structural drawings by VanDenBrink Engineering LTD. -These drawings are based on the original drawings and details created by Rositch Hemphill Architects, and have been subsequently modified and/or reformatted by Precision Building Design Associates Ltd.
unit number:
May 7, 2018
MAIN FLOOR PLAN 1285 SQ. FT. MAIN FLOOR AREA INCLUDING STAIRS/EXCLUDING SCREENED PORCH 990 SQ. FT. LOFT FLOOR AREA EXCLUDING STAIRS 2275 SQ. FT. TOTAL FLOOR AREA
ENG. DROP BEAM
2x10 RAFTERS @ 24" OC
2x10 RAFTERS @ 24" OC
2' - 0" 2' - 0" 28' - 0" 2' - 0"
7' - 2" 6' - 10" 6' - 10" 7' - 2"
2 ' -
0 "
3' - 0" 32' - 0" 2' - 0"
2' - 0" 2' - 0" 10' - 4" 7' - 4" 10' - 4" 2' - 0"
2' - 0" 7' - 2" 3' - 2" 3' - 2" 7' - 2"
1' - 5" 1' - 9" 3' - 8" 3' - 8" 1' - 9" 1' - 5"
2 ' -
0 "
1' -
9 "
2' - 0" 7' - 2" 3' - 8" 2' - 4" 2' - 4" 3' - 10" 1' - 6" 7' - 2" 2' - 0"
2' - 0" 7' - 2" 3' - 8" 2' - 4" 4' - 10" 2' - 10" 2' - 4" 4' - 10" 2' - 0"
4' - 0" 3' - 8" 1' - 6" 5' - 8"
5 ' -
8 "
6 ' -
0 "
6 ' -
0 "
5 ' -
8 "
SLOPE TO DRAIN SCUPPERS
BALCONY WALLS 3'-6" MIN.
Precision Building Design Associates Chilliwack, B.C. (604) 792-0826
-Drawings are subject to change without notice. The developer reserves the to make modifications to the drawings at their sole discretion in accordance with building code guidelines and to maintain the high quality of the homes. -Window sizes are subject to change from site to site based on site limiting distance calculations. -Drawings to be read in conjunction with structural drawings by VanDenBrink Engineering LTD. -These drawings are based on the original drawings and details created by Rositch Hemphill Architects, and have been subsequently modified and/or reformatted by Precision Building Design Associates Ltd.
unit number:
May 7, 2018