FRONT ELEVATION - Boston.gov · front elevation (from bpda zoning viewer) rear elevation. chestnut...

15
LOCUS MAP FRONT ELEVATION (from BPDA Zoning Viewer) REAR ELEVATION

Transcript of FRONT ELEVATION - Boston.gov · front elevation (from bpda zoning viewer) rear elevation. chestnut...

Page 1: FRONT ELEVATION - Boston.gov · front elevation (from bpda zoning viewer) rear elevation. chestnut street spruce place proposed balcony chestnut street spruce street spruce street

LOCUS MAP

FRONT ELEVATION

(from BPDA Zoning Viewer)REAR ELEVATION

Page 2: FRONT ELEVATION - Boston.gov · front elevation (from bpda zoning viewer) rear elevation. chestnut street spruce place proposed balcony chestnut street spruce street spruce street

CHESTNUT STREET

SPRUCE PLACE

PROPOSED BALCONY

CHESTNUT STREETSP

RU

CE

STR

EET

SPR

UC

E ST

REE

T

30CHESTNUT

STREET

32CHESTNUT

STREET

28CHESTNUT

STREET

30CHESTNUT

STREET

32CHESTNUT

STREET

28CHESTNUT

STREET

GARAGEROOF

GARAGEROOF

GARAGEROOF

GARAGEROOF

GARAGEROOF

GARAGEROOF

PROPOSED ROOF DECK

PROPOSEDROOF DECK

SPRUCE PLACE

p&Com Ina y, .cnoh oC

One Billings Road Quincy, MA 02171617-786-7727 fax 617-786-7715

oh oCpCom Ina y, .cn&

30 CHESTNUT STREET, BOSTON, MA 02108

EXISTING SITE PLANNTS1 PROPOSED SITE PLAN

NTS2

Page 3: FRONT ELEVATION - Boston.gov · front elevation (from bpda zoning viewer) rear elevation. chestnut street spruce place proposed balcony chestnut street spruce street spruce street

28 CHESTNUT STREET

30 CHESTNUT STREET

32 CHESTNUT STREET

p&Com Ina y, .cnoh oC

One Billings Road Quincy, MA 02171617-786-7727 fax 617-786-7715

oh oCpCom Ina y, .cn&

30 CHESTNUT STREET, BOSTON, MA 02108

EXISTING CHESTNUT STREET ELEVATION1/4" = 1'-0"1

Page 4: FRONT ELEVATION - Boston.gov · front elevation (from bpda zoning viewer) rear elevation. chestnut street spruce place proposed balcony chestnut street spruce street spruce street

28 CHESTNUT STREET

30 CHESTNUT STREET

32 CHESTNUT STREET

2'-0

"

1'-5

" ±

CH

IMN

EYEX

TEN

SIO

N

2 1 4"

2 3 4"

2 1 4"

12 WINDOW

WIDTH

VA

RIE

S ( 1

1 2" <

MA

SON

RY

OPE

NIN

G)

2" x 38" LOUVERS

1 38"

1"

1 38" VARIES

CUSTOM WOOD SHUTTERSBY SOUTHERN SHUTTER COMPANYOR EQUIVALENT. DIMENSIONSBASED ON EX'G SHUTTER

COLOR: BENJAMIN MOORE BLACKHC-190

5/8"

1 3/

8"

1 5/

8"

1 1/

4"

1"2

1/2"

2 3/

4"

1 1/2"

2 1/

4"

2 1/

2"

1 7/16"

3 5/8"

3/8"

1 1/

2"1

1/2"

3/8"

3/8"

3 5/

8"

EX'G MASONRY WALLEX'G EXT MOLDING

3 3/

4"

1 5/8"

5/8"

3/4"

3/8"

1 3/

8"

WINDOW JAMB DETAILWINDOW HEAD-SILL DETAIL

WINDOW MUNTIN DETAIL

p&Com Ina y, .cnoh oC

One Billings Road Quincy, MA 02171617-786-7727 fax 617-786-7715

oh oCpCom Ina y, .cn&

30 CHESTNUT STREET, BOSTON, MA 02108

PROPOSED CHESTNUT STREET ELEVATION1/4" = 1'-0"1

PROPOSED WINDOW DETAILS1 1/2" = 1'-0"2

PROPOSED SHUTTER ELEVATION DETAIL1"=1'-0"3

MOLDED 1 3/4" TUBULAR HANDRAIL

PROPOSED HANDRAILSNTS4

WITH LAMB'S TONGUE TERMINATIONS

Page 5: FRONT ELEVATION - Boston.gov · front elevation (from bpda zoning viewer) rear elevation. chestnut street spruce place proposed balcony chestnut street spruce street spruce street

CLOSET

BEDROOM

BEDROOM BEDROOM

9'-3" ±14'-10" ±

5'-2

" ±

6'-2

" ±

6'-6

" ±

4'-1

0" ±

5'-1

0" ±

8'-0

" ±

3'-9

" ±

14'-2

" ±

9'-5" ±14'-6" ±

17'-1

1" ±

8'-0

" ±

17'-1

" ±

4'-6" ±4'-10" ±6'-11" ±2'-9" ±5'-0" ±

AD

JAC

ENT

BU

ILD

ING

AD

JAC

ENT

BU

ILD

ING

CHESTNUT STREET

SPRUCE PLACE

CLOSET

BEDROOM

BEDROOM BEDROOM

9'-3" ±14'-10" ±

5'-2

" ±

6'-2

" ±

6'-6

" ±

4'-1

0" ±

5'-1

0" ±

8'-0

" ±

3'-9

" ±

14'-2

" ±

9'-5" ±14'-6" ±

17'-1

1" ±

8'-0

" ±

17'-1

" ±

6'-11" ±2'-9" ±5'-0" ±

CHESTNUT STREET

DN

UP

4 1/8"4'-0 3/8"

AD

JAC

ENT

BU

ILD

ING

AD

JAC

ENT

BU

ILD

ING

SPRUCE PLACE

p&Com Ina y, .cnoh oC

One Billings Road Quincy, MA 02171617-786-7727 fax 617-786-7715

oh oCpCom Ina y, .cn&

30 CHESTNUT STREET, BOSTON, MA 02108

EXISTING FOURTH FLOOR PLAN1/4" = 1'-0"1 PROPOSED FOURTH FLOOR PLAN

1/4" = 1'-0"2

AutoCAD SHX Text
DN
AutoCAD SHX Text
UP
Page 6: FRONT ELEVATION - Boston.gov · front elevation (from bpda zoning viewer) rear elevation. chestnut street spruce place proposed balcony chestnut street spruce street spruce street

CHESTNUT STREET

SPRUCE PLACE

STOR

AG

E

17'-7" ±

2'-0" ±

5'-6" ±

20'-1

" ±

4'-1" ± 3'-0" ±

CHESTNUT STREET

ALIGN

17'-6 1/2"EXISTING

3'-0"PROP.ADD.

2'-5"PROP.ADD.

23'-0" ±

20'-0

1/2

" N

O C

HA

NG

E7'

-4"

±7'

-7"

±PR

OP.

RO

OF

DEC

K8'

-6"

±

22'-11 1/2"PROPOSED ROOF DECK

SLO

PED

OW

NSL

OPE

DO

WN

DN

ROOFDECK

AD

JAC

ENT

BU

ILD

ING

AD

JAC

ENT

BU

ILD

ING

SPRUCE PLACE

FAMILYROOM

HVAC

p&Com Ina y, .cnoh oC

One Billings Road Quincy, MA 02171617-786-7727 fax 617-786-7715

oh oCpCom Ina y, .cn&

30 CHESTNUT STREET, BOSTON, MA 02108

EXISTING FIFTH FLOOR PLAN1/4" = 1'-0"1 PROPOSED FIFTH FLOOR PLAN

1/4" = 1'-0"2

AutoCAD SHX Text
DN
Page 7: FRONT ELEVATION - Boston.gov · front elevation (from bpda zoning viewer) rear elevation. chestnut street spruce place proposed balcony chestnut street spruce street spruce street

5'-6

"

PRO

PER

TY L

INE

GRADE

PRO

PER

TY L

INE

PRO

PER

TY L

INE

13'-0"±SPRUCE PLACE

88'-2"±30 CHESTNUT

47'-4"±CHESTNUT STREET

PROPOSED ROOF DECK& GUARDRAIL

PROPOSED LOCATION OFRELOCATED HVAC UNIT

HVAC UNIT TO BERELOCATED

PROPOSED SITE SECTION FROM SPRUCE PLACE THROUGH CHESTNUT STREET

p&Com Ina y, .cnoh oC

One Billings Road Quincy, MA 02171617-786-7727 fax 617-786-7715

oh oCpCom Ina y, .cn&

30 CHESTNUT STREET, BOSTON, MA 02108

Page 8: FRONT ELEVATION - Boston.gov · front elevation (from bpda zoning viewer) rear elevation. chestnut street spruce place proposed balcony chestnut street spruce street spruce street

28 CHESTNUT STREET

30 CHESTNUT STREET

32 CHESTNUT STREET

30 CHESTNUT STREET

32 CHESTNUT STREET

p&Com Ina y, .cnoh oC

One Billings Road Quincy, MA 02171617-786-7727 fax 617-786-7715

oh oCpCom Ina y, .cn&

30 CHESTNUT STREET, BOSTON, MA 02108

EXISTING SPRUCE PLACE ELEVATION1/4" = 1'-0"1

Page 9: FRONT ELEVATION - Boston.gov · front elevation (from bpda zoning viewer) rear elevation. chestnut street spruce place proposed balcony chestnut street spruce street spruce street

2'-0

"

1'-5

" ±

CH

IMN

EYEX

TEN

SIO

N

28 CHESTNUT STREET

30 CHESTNUT STREET

32 CHESTNUT STREET

NEW WOOD WINDOWS, TYP.

CLEAN ALL MASONRY W/WATER & GENTLEDETERGENTRE-POINT BRICK AS REQUIREDW/ FOLLOWING MORTAR MIX;1 PART CEMENT2 PARTS LIME7-9 PARTS SAND

NEW COPPER GUTTER &RELOCATE DOWNSPOUTTO COURTYARD

NEW STEEL CANTILEVEREDBALCONYW/ BRACKETS, 1ST &2ND FLOORS, PAINTED BLACK

RELOCATED HVAC UNIT

HVAC UNIT TO BERELOCATED

3'-6

" NEW ROOF DECK & STEELGUARDRAIL, PAINTED BLACK

REPAIR EX'G CAST STONEHEADER

2'-10"2'-10"

6'-8

"

4'-6

"

ALIGN

PROPOSED5TH FLR DOOR

PROPOSED5TH FLR WINDOW

p&Com Ina y, .cnoh oC

One Billings Road Quincy, MA 02171617-786-7727 fax 617-786-7715

oh oCpCom Ina y, .cn&

30 CHESTNUT STREET, BOSTON, MA 02108

PROPOSED SPRUCE PLACE ELEVATION1/4" = 1'-0"1

PROPOSED DOOR & WINDOW TYPESNTS2

Page 10: FRONT ELEVATION - Boston.gov · front elevation (from bpda zoning viewer) rear elevation. chestnut street spruce place proposed balcony chestnut street spruce street spruce street

15'-0"

13'-0

"

3'-0"

8'-4

" ±

2'-4" ±

GARAGEROOF

GARAGEROOF

GARAGEROOF

PROPOSEDROOF DECK

SPRUCE PLACE

PRO

PER

TY L

INE

13'-0"±SPRUCE PLACE

28 CHESTNUT STREET

30 CHESTNUT STREET

32 CHESTNUT STREET

3'-6

"

p&Com Ina y, .cnoh oC

One Billings Road Quincy, MA 02171617-786-7727 fax 617-786-7715

oh oCpCom Ina y, .cn&

30 CHESTNUT STREET, BOSTON, MA 02108

PROPOSED GARAGE ROOF DECK ELEVATIONNTS2

PROPOSED GARAGE ROOF PLANNTS1

Page 11: FRONT ELEVATION - Boston.gov · front elevation (from bpda zoning viewer) rear elevation. chestnut street spruce place proposed balcony chestnut street spruce street spruce street

SPRUCE PLACE

LIVINGROOM

BALCONY

4'-0

"

21'-0" 1'-8" ±2'-8" ±

3'-6

" ±

8" ±

3'-1

0" ±

4"

4"

45°

4'-0"

2'-0

"

1'-5

" ±

CH

IMN

EYEX

TEN

SIO

N

28 CHESTNUT STREET

30 CHESTNUT STREET

32 CHESTNUT STREET

3'-6

"

PROPOSED2ND FLR DOOR

PROPOSED1ST FLR DOOR

p&Com Ina y, .cnoh oC

One Billings Road Quincy, MA 02171617-786-7727 fax 617-786-7715

oh oCpCom Ina y, .cn&

30 CHESTNUT STREET, BOSTON, MA 02108

PROPOSED REAR ELEVATIONNTS1

PROPOSED ELEVATION DETAIL & SECTIONNTS2

PROPOSED BALCONY PLAN, 1ST & 2ND FLOORSNTS3 PROPOSED DOOR TYPES

NTS4

Page 12: FRONT ELEVATION - Boston.gov · front elevation (from bpda zoning viewer) rear elevation. chestnut street spruce place proposed balcony chestnut street spruce street spruce street

10"

10 1 2"

7"

7 1 2"

p&Com Ina y, .cnoh oC

One Billings Road Quincy, MA 02171617-786-7727 fax 617-786-7715

oh oCpCom Ina y, .cn&

30 CHESTNUT STREET, BOSTON, MA 02108

EXISTING SPRUCE PLACE CURB ELEVATION & SECTION1/4" = 1'-0"1

PROPOSED SPRUCE PLACE CURB ELEVATION & SECTION1/4" = 1'-0"2

Page 13: FRONT ELEVATION - Boston.gov · front elevation (from bpda zoning viewer) rear elevation. chestnut street spruce place proposed balcony chestnut street spruce street spruce street
Page 14: FRONT ELEVATION - Boston.gov · front elevation (from bpda zoning viewer) rear elevation. chestnut street spruce place proposed balcony chestnut street spruce street spruce street
Page 15: FRONT ELEVATION - Boston.gov · front elevation (from bpda zoning viewer) rear elevation. chestnut street spruce place proposed balcony chestnut street spruce street spruce street