Four-wire Signal Conditioners - M-System - Total … · 2009-11-05 · for processing after...

13
A 1 ISP1-1 Four-wire Signal Conditioners Converting a field signal suitable for processing after conditioning Available with wide combination of process signal I/O, power input and mounting configuration. Additionally, M-System offers the broadest line of signal splitters available. Signal Conversion Signal Boosting (increases load drive capability) Signal Isolation (stops ground loops)

Transcript of Four-wire Signal Conditioners - M-System - Total … · 2009-11-05 · for processing after...

A

1ISP1-1

Four-wire Signal Conditioners

Converting a field signal suitable for processing after conditioning

Available with wide combination of process signal I/O, power input and mounting configuration.

Additionally, M-System offers the broadest line of signal splitters available.

✔ Signal Conversion✔ Signal Boosting (increases load drive capability)✔ Signal Isolation (stops ground loops)

A

8

Four-wire Signal Conditioners

Two-wire Signal Conditioners

Power Transducers

Indicators

Limit Alarms

Gateway,Remote I/O

Paperless RecordingSystem

PC Recorder

Electronic Actuators& Position Sensors Lightning Surge Protectors

Data sheets available on Web in PDF. Visit M-System Data Library at www.m-system.co.jp ISP1-1

Mini-MW Series

M6 Series

M5-UNIT Series

W5-UNIT Series

M3-UNIT Series

M3S-UNIT Series

Pico-M Series

MX-UNIT Series

M-UNIT Series

W-UNIT Series

K-UNIT Series

F-UNIT Series

H-UNIT Series

10-RACK Series

18-RACK Series

38-RACK Series Rack

-mou

nted

Four-wire Product Selection Guide

Compact Plug-in

Mini-M Series

Mini-M Series

Four

-wire

Sig

nal C

ondi

tione

rs

n DC Inputs, IsolatorsModel Function PageM2SN Input Loop Powered Isolator P.10

M2XU Universal Transmitter (PC programmable) P.10

M2XUM Universal Transmitter (PC programmable; Modbus-RTU communication) P.11

M2XV2 Signal Transmitter (PC programmable) P.11

M2LV Signal Transmitter (field- and PC-configurable) P.12

M2VS Signal Transmitter P.12

M2VF Signal Transmitter (high speed response) P.12

M2VF2 Signal Transmitter (ultra-high speed response 30μsec.) P.13

M2VV Voltage Divider P.13

n Temperature & Sensor InputsModel Function PageM2XT2 Thermocouple Transmitter (PC programmable) P.13

M2TS Thermocouple Transmitter P.14

M2XR2 RTD Transmitter (PC programmable) P.14

M2LR RTD Transmitter (field- and PC-configurable) P.14

M2RS RTD Transmitter P.15

M2RR Resistance/Resistance Converter P.15

M2XM2 Potentiometer Transmitter (PC programmable) P.15

M2LPM Potentiometer Transmitter (field- and PC-configurable) P.16

M2MS Potentiometer Transmitter P.16

M2LCS Strain Gauge Transmitter P.16

M2TG Tachogenerator Transmitter P.17

M2AC AC Transmitter P.17

s SPECIFICATIONS s EXTERNAL DIMENSIONS

5

9

21.5 (.85)

70.5

(2.78

)

84 (3.31)10 (.39) 15 (.59)

6 (.23)

59 (2

.32)

DIN RAIL35mm wide

[4 (.16)]

8–M3SCREW

72 (2

.83)

23 (.91)

2–4.2x5(.17x.20)

MTG HOLE6 (.24) deep

114 (4.49)

• When mounting, no extra space is needed between units.

48

1214 13

1

4 (.16

)

Construction Plug-inConnection M3 screw terminals (torque 0.8 N·m)Housing material Flame-resistant resin (black)Isolation Input to output to power Operating temperature -5 to +55°C (23 to 131°F)Mounting Surface or DIN rail

Dielectric strength 2000V AC @1 minute (input to output to power to ground)

AC power input Operational voltage range 85 – 264V (90 – 264V for UL)

DC power input Operational voltage range for 24V ±10%, 11 – 27V, or 85 – 150V (110V ±10% for UL)

8-pin Mounted Modules

M2 Series Signal Conditioners are designed to accept a largest range of process signal inputs and provide a standard and non-standard DC output.

M2 use a compact-size, plug-in socket base for n

quick installation or replacement of modules without disturbing wiring.

2000V AC isolation n

Standard DIN rail or surface mounting n

Base socket included with modules n

Selectable 100–240V AC/24V DC power input n

Fixed range or PC programmable models n

selectable

CE marking and UL/C-UL Class 1 Div 2 approval n

(selected models)

mm (inch)

AFour-wire Signal Conditioners

Two-wire Signal Conditioners

Power Transducers

Indicators

Limit Alarms

Gateway,Remote I/O

Paperless RecordingSystem

PC Recorder

Electronic Actuators& Position Sensors

Lightning Surge Protectors

9

Mini-MW Series

M6 Series

M5-UNIT Series

W5-UNIT Series

M3-UNIT Series

M3S-UNIT Series

Pico-M Series

MX-UNIT Series

M-UNIT Series

W-UNIT Series

K-UNIT Series

F-UNIT Series

H-UNIT Series

10-RACK Series

18-RACK Series

38-RACK SeriesRack

-mou

nted

Four-wire Product Selection Guide

Specifications are subject to change without notice.ISP1-1

Compact Plug-in Mini-M Series

Mini-M Series

Four

-wire

Sig

nal C

ondi

tione

rs

Model Function PageM2PA PT Transmitter (average) P.17

M2PE PT Transmitter (RMS) P.17

M2CA CT Transmitter (average) P.18

M2CE CT Transmitter (RMS) P.18

M2CEC AC Current Transmitter (clamp-on current sensor) P.18

n DC SuppliesModel Function PageM2D Current Loop Supply (non-isolated) P.18

M2D2 Current Loop Supply (non-isolated) P.18

M2DYS Current Loop Supply P.19

M2DY Current Loop Supply P.19

M2DL Current Loop Supply (with square root extractor; non-isolated) P.19

M2DNY Current Loop Supply (with square root extractor) P.19

M2DYH Current Loop Supply (applicable to HART signal) P.19

M2DU Current Loop Supply (10-50mA loop) P.19

n Pneumatic TransducersModel Function PageM2PV P/I Transducer P.20

n Limit AlarmsModel Function PageM2AVS DC Alarm P.20

M2SED DC Alarm (thumbwheel switch adjustment) P.20

M2AS DC Alarm (thumbwheel switch adjustment; DPDT output) P.20

M2AS1 DC Alarm (thumbwheel switch adjustment; single SPDT output) P.21

n Frequency I/OModel Function PageM2XPA3 Frequency Transmitter (PC programmable) P.21

M2XPA2 Frequency Transmitter (PC programmable) P.21

M2SP Low Frequency Transmitter (50 Hz minimum) P.22

M2XRP2 Encoder Speed Transmitter (PC programmable; built-in excitation) P.22

M2AP DC/Frequency Converter P.22

M2PP Pulse Isolator P.22

M2PRU Pulse Scaler (selectable range) P.23

n Function ModulesModel Function PageM2ADS Adder P.23

M2SBS Subtractor P.23

M2MLS Multiplier P.24

M2DIS Divider P.24

M2REB Ratio/Bias Transmitter (output bias) P.24

M2RTS Ratio/Bias Transmitter (input bias) P.25

M2XF2 Linearizer (PC programmable) P.25

M2FL Square Root Extractor (non-isolated) P.25

M2FLS Square Root Extractor P.25

M2LMS Limiter P.26

M2UDS2 Inverted Output Transmitter (with simple loop test output) P.26

M2UDS Inverted Output Transmitter P.26

M2CDS Delay Buffer P.27

M2CRS Ramp Buffer P.27

M2AMS2 Track/Hold (with simple loop test output) P.27

M2AMS Track/Hold P.28

M2PHS2 Peak Hold (with simple loop test output) P.28

M2PHS Peak Hold P.28

M2SES2 High/Low Selector (with simple loop test output) P.29

M2SES High/Low Selector P.29

M2MNV Analog Switching Module P.29

M2MST Parameter Generator P.29

n Installation BaseModel Function PageM2BS-16 Installation Base (16 positions) ***M2BS-8 Installation Base (8 positions) ***

M2BS2 Installation Base (for 61-UNIT series analog I/O modules) ***

M2BC Communication Controller (Mitsubishi Control & Communication Link use) ***

M2BD Communication Controller (DeviceNet use) ***

To find a product in the list with “***”, visit M-System Data Library.If you cannot find a product here, please contact: [email protected]

A

30

Two-wire Signal Conditioners

Power Transducers

Indicators

Limit Alarms

Gateway,Remote I/O

Paperless RecordingSystem

PC Recorder

Electronic Actuators& Position Sensors Lightning Surge Protectors

Data sheets available on Web in PDF. Visit M-System Data Library at www.m-system.co.jp ISP1-1

Mini-M Series

M6 Series

M5-UNIT Series

W5-UNIT Series

M3-UNIT Series

M3S-UNIT Series

Pico-M Series

MX-UNIT Series

M-UNIT Series

W-UNIT Series

K-UNIT Series

F-UNIT Series

H-UNIT Series

10-RACK Series

18-RACK Series

38-RACK Series Rack

-mou

nted

Four-wire Product Selection Guide

Compact Plug-in Signal Splitters

Mini-MW Series

Mini-MW Series

Four

-wire

Sig

nal C

ondi

tione

rsFour-wire Signal Conditioners

n DC SuppliesModel Function PageW2DYS Current Loop Supply P.34

W2DY Current Loop Supply P.35

W2DNY Current Loop Supply (with square root extractor) P.35

W2DYH Current Loop Supply (applicable to HART signal) P.35

n Pneumatic TransducersModel Function PageW2PV P/I Transducer P.36

n Frequency I/OModel Function PageW2SP Low Frequency Transmitter (50 Hz minimum) P.36

W2AP DC/Frequency Converter P.36

W2PP Pulse Isolator P.37

n DC InputsModel Function PageW2VS Signal Transmitter P.31

W2VF Signal Transmitter (high speed response) P.31

n Temperature & Sensor InputsModel Function PageW2TS Thermocouple Transmitter P.31

W2XR RTD Transmitter (PC programmable) P.32

W2RS RTD Transmitter P.32

W2XM Potentiometer Transmitter (PC programmable) P.32

W2MS Potentiometer Transmitter P.33

W2TG Tachogenerator Transmitter P.33

W2AC AC Transmitter P.33

W2PA PT Transmitter (average) P.34

W2PE PT Transmitter (RMS) P.34

W2CA CT Transmitter (average) P.34

W2CE CT Transmitter (RMS) P.34

s SPECIFICATIONS s EXTERNAL DIMENSIONS

4

8 710

23 (.91)

89 (3

.50)

84 (3.31)10 (.39)

22 (.87)

59 (2

.32)

DIN RAIL35mm wide

[4 (.16)]

11–M3SCREW

72 (2

.83)

29.5 (1.16)

53 (2

.09)

2–4.2x5(.17x.20)

MTG HOLE6 (.24) deep

114 (4.49)

11

56123

9

6 (.23)

• When mounting, no extra space is needed between units.

Construction Plug-inConnection M3 screw terminals (torque 0.8 N·m)Housing material Flame-resistant resin (black)Isolation Input to output 1 to output 2 to powerOperating temperature -5 to +55°C (23 to 131°F)Mounting Surface or DIN rail

Dielectric strength 2000V AC @1 minute (input to output 1 to output 2 to power to ground)

AC power input Operational voltage range 85 – 264V (90 – 264V for UL)

DC power input Operational voltage range for 24V ±10%, 11 – 27V, or 85 – 150V (110V ±10% for UL)

The W2 Series Signal Splitters provide two isolated outputs of independent ranges.

W2 use a compact-size, plug-in socket base for n

quick installation or replacement of modules without disturbing wiring.

2000V AC isolation n

Standard DIN rail or surface mounting n

Base socket included with modules n

Selectable 100–240V AC/24V DC power input n

Fixed range or PC programmable models n

selectable

CE marking and UL/C-UL Class 1 Div 2 approval n

(selected models)

mm (inch)

A

38

Four-wire Signal Conditioners

Two-wire Signal Conditioners

Power Transducers

Indicators

Limit Alarms

Gateway,Remote I/O

Paperless RecordingSystem

PC Recorder

Electronic Actuators& Position Sensors Lightning Surge Protectors

Data sheets available on Web in PDF. Visit M-System Data Library at www.m-system.co.jp ISP1-1

Mini-M Series

Mini-MW Series

M5-UNIT Series

W5-UNIT Series

M3-UNIT Series

M3S-UNIT Series

Pico-M Series

MX-UNIT Series

M-UNIT Series

W-UNIT Series

K-UNIT Series

F-UNIT Series

H-UNIT Series

10-RACK Series

18-RACK Series

38-RACK Series Rack

-mou

nted

Four-wire Product Selection Guide

Ultra-Slim

M6 Series

M6 Series

Four

-wire

Sig

nal C

ondi

tione

rs Model Function PageM6SSN Input Loop Powered Isolator P.41

M6SYV Isolator P.41

M6SXV Signal Transmitter (PC programmable) P.41

M6SVS Signal Transmitter P.41

M6SWVS Signal Transmitter (two isolated outputs) P.41

M6SXT Thermocouple Transmitter (PC programmable) P.42

M6SXR RTD Transmitter (PC programmable) P.42

M6SXM Potentiometer Transmitter (PC programmable) P.42

M6SDY Current Loop Supply P.43

M6SCTC CT Transmitter (clamp-on current sensor) P.43

M6SPA Frequency Transmitter P.43

M6SXAS DC Alarm (PC programmable) P.43

M6SXF1 Function Module (PC programmable) P.44

M6SXF2 2-input Math Function Module (PC programmable) P.44

M6SXF3 Hold Function Module (PC programmable) P.45

n AccessoriesModel Function PageM6SBS Installation Base P.45

M6SPS1 Power Supply Module P.45

M6SPS2 Power Supply Module (dual redundant) P.45

M6SDM Blank Filler Module P.45

n Tension-Clamp Ultra-Slim Signal Conditioners M6S Series

s SPECIFICATIONS

Tension-Clamp(M6S Series)

Screw Terminal(M6N Series)

Euro Terminal(M6D Series)

5.9 mm (0.23”) wide ultra-slim design n

Spring terminal provides constant force, eliminating n

torque management, maintenance- free for retightening

Construction Ultra-slim

ConnectionM6S: Tension clampM6N: M3 screw terminal (torque 0.5 N·m) M6D: Euro terminal (torque 0.3 N·m)

Housing material Flame-resistant resin (black)

Isolation Input to output to power/ Input to output 1 to output 2 to power

Operating temperature -20 to +55°C (-4 to +131°F)Mounting DIN rail

Dielectric strength 2000V AC @1 minute (input to output to power to ground)

Power input Operational voltage range 24V DC ±10%5.9mm (0.23”)

7.5mm (0.30”)

5.9mm (0.23”)

Ultra-slim, Space saving, Low power consumption. High performance transmitters with wide selection of input and output ranges.

Selectable connection method – Tension-Clamp, Screw terminal or Euro terminal. n

Output load resistance 550Ω (at 4–20mA DC) n

Low power consumption n

Front power LED provided n

Fixed range or PC programmable models selectable. User-friendly versatile programming features provided. n

Status LED for PC programmable models. n

2000V AC isolation n

Optional fast response: Approx. 3.5 msec, n

voltage output (M6xYV)

UL/C-UL approval (pending as of August ’09)

s EXTERNAL DIMENSIONS

94 (3

.70)

5.9 (.23)

DIN RAIL35mm wide

DIN RAIL HOOK

102 (4.02) [0.5 (.02)]

5 6 7 8

1 2 3 4

• When mounting, no extra space is needed between units.

mm (inch)

AFour-wire Signal Conditioners

Two-wire Signal Conditioners

Power Transducers

Indicators

Limit Alarms

Gateway,Remote I/O

Paperless RecordingSystem

PC Recorder

Electronic Actuators& Position Sensors

Lightning Surge Protectors

39

Mini-M Series

Mini-MW Series

M5-UNIT Series

W5-UNIT Series

M3-UNIT Series

M3S-UNIT Series

Pico-M Series

MX-UNIT Series

M-UNIT Series

W-UNIT Series

K-UNIT Series

F-UNIT Series

H-UNIT Series

10-RACK Series

18-RACK Series

38-RACK SeriesRack

-mou

nted

Four-wire Product Selection Guide

Specifications are subject to change without notice.ISP1-1

Ultra-Slim M6 Series

M6 Series

Four

-wire

Sig

nal C

ondi

tione

rsModel Function PageM6DSN Input Loop Powered Isolator P.51

M6DYV Isolator P.51

M6DXV Signal Transmitter (PC programmable) P.51

M6DVS Signal Transmitter P.51

M6DWVS Signal Transmitter (two isolated outputs) P.51

M6DXT Thermocouple Transmitter (PC programmable) P.52

M6DXR RTD Transmitter (PC programmable) P.52

M6DXM Potentiometer Transmitter (PC programmable) P.52

M6DDY Current Loop Supply P.53

M6DCTC CT Transmitter (clamp-on current sensor) P.53

M6DPA Frequency Transmitter P.53

M6DXAS DC Alarm (PC programmable) P.53

M6DXF1 Function Module (PC programmable) P.54

M6DXF2 2-input Math Function Module (PC programmable) P.54

M6DXF3 Hold Function Module (PC programmable) P.55

n AccessoriesModel Function PageM6DBS Installation Base P.55

M6DPS1 Power Supply Module P.55

M6DPS2 Power Supply Module (dual redundant) P.55

M6DDM Blank Filler Module P.55

Model Function PageM6NSN Input Loop Powered Isolator P.46

M6NYV Isolator P.46

M6NXV Signal Transmitter (PC programmable) P.46

M6NVS Signal Transmitter P.46

M6NWVS Signal Transmitter (two isolated outputs) P.46

M6NXT Thermocouple Transmitter (PC programmable) P.47

M6NXR RTD Transmitter (PC programmable) P.47

M6NXM Potentiometer Transmitter (PC programmable) P.47

M6NDY Current Loop Supply P.48

M6NCTC CT Transmitter (clamp-on current sensor) P.48

M6NPA Frequency Transmitter P.48

M6NXAS DC Alarm (PC programmable) P.48

M6NXF1 Function Module (PC programmable) P.49

M6NXF2 2-input Math Function Module (PC programmable) P.49

M6NXF3 Hold Function Module (PC programmable) P.50

n AccessoriesModel Function PageM6NBS Installation Base P.50

M6NPS1 Power Supply Module P.50

M6NPS2 Power Supply Module (dual redundant) P.50

M6NDM Blank Filler Module P.50

n Euro Terminal Ultra-Slim Signal Conditioners M6D Series

n Screw Terminal Ultra-Slim Signal Conditioners M6N Series

5.9 mm (0.23”) wide ultra-slim design n

Space saving euro type terminal n

7.5 mm (0.30”) wide ultra-slim design n

Self-up screw style prevents falling off a terminal n

s EXTERNAL DIMENSIONS

102 (

4.02)

7.5 (.30)

DIN RAIL HOOK

102 (4.02)[1 (.04)]

8–M3SCREW TERMINAL

DIN RAIL35mm wide

5 6 7 8

1 2 3 4

• When mounting, no extra space is needed between units.

mm (inch)

s EXTERNAL DIMENSIONS

94 (3

.70)

5.9 (.23)

DIN RAIL HOOK

102 (4.02)[0.5 (.02)]

8–M3EURO TERMINAL

DIN RAIL35mm wide

5 6 7 8

1 2 3 4

• When mounting, no extra space is needed between units.

mm (inch)

40

Two-wire Signal Conditioners

Power Transducers

Indicators

Limit Alarms

Gateway,Remote I/O

Paperless RecordingSystem

PC Recorder

Electronic Actuators& Position Sensors Lightning Surge Protectors

Data sheets available on Web in PDF. Visit M-System Data Library at www.m-system.co.jp ISP1-1

Mini-M Series

Mini-MW Series

M5-UNIT Series

W5-UNIT Series

M3-UNIT Series

M3S-UNIT Series

Pico-M Series

MX-UNIT Series

M-UNIT Series

W-UNIT Series

K-UNIT Series

F-UNIT Series

H-UNIT Series

10-RACK Series

18-RACK Series

38-RACK Series Rack

-mou

nted

Four-wire Product Selection Guide

Ultra-Slim M6 Series

Power supply module (Model : M6xPS1)orFor redundant power supplies (Model : M6xPS2)

Installation Base(Model : M6xBS)

Max. 48 modules

9.5 cm(3.75”)

49 (1.93)37 (1.46)

11.5 (.45)

3–4.5 (.18) dia. MTG HOLE2 (.08) deep

99 (3

.90)

70 (2

.76)

5 (.20

)5 (

.20)

14

(.55)

27 (1.06) [5 (.20)]

22.5 (.89)116 (4.57)

[3 (.12)]

14 (.55)

49 (1

.93)

DIN RAIL35mm wide

11.5 (.45)

101 (

3.98)

72 (2

.83)

5 (.20

)5 (

.20)

14

(.55)

61.6 (2.43) [3 (.12)]3–4.5 (.18) dia.MTG HOLE2 (.08) deep

49.8 (1.96)

[5 (.20)]

2 (.08

)51

(2.01

)

22.5 (.89)116 (4.57)

DIN RAIL35mm wide

27 (1.06)

18 (.7

1)

49 (1.93)37 (1.46)

11.5 (.45)

3–4.5 (.18) dia. MTG HOLE2 (.08) deep

99 (3

.90)

70 (2

.76)

5 (.20

)5 (

.20)

14

(.55)

27 (1.06) [5 (.20)]

22.5 (.89)116 (4.57)

[3 (.12)]

14 (.55)

49 (1

.93)

DIN RAIL35mm wide

11.5 (.45)

101 (

3.98)

72 (2

.83)

5 (.20

)5 (

.20)

14

(.55)

61.6 (2.43) [3 (.12)]3–4.5 (.18) dia.MTG HOLE2 (.08) deep

49.8 (1.96)

[5 (.20)]

2 (.08

)51

(2.01

)

22.5 (.89)116 (4.57)

DIN RAIL35mm wide

27 (1.06)

18 (.7

1)

n M6DBS

11.5 (.45)

99 (3

.90)

70 (2

.76)

5 (.20

)5 (

.20)

14

(.55)

37 (1.46) 3–4.5 (.18) dia.MTG HOLE2 (.08) deep

49 (1.93) [3 (.12)]

14 (.55)

22.5 (.89)116 (4.57)

27 (1.06) [5 (.20)]

49 (1

.93)

DIN RAIL35mm wide

11.5 (.45)

99 (3

.90)

70 (2

.76)

5 (.20

)5 (

.20)

14

(.55)

37 (1.46) 3–4.5 (.18) dia.MTG HOLE2 (.08) deep

49 (1.93) [3 (.12)]

14 (.55)

22.5 (.89)116 (4.57)

27 (1.06) [5 (.20)]

49 (1

.93)

DIN RAIL35mm wide

n M6NBSn M6SBS

M6 Series

Four

-wire

Sig

nal C

ondi

tione

rsFour-wire Signal Conditioners

A

Power supply through the backplane bus 16 modules in a 9.5 cm- (3.75 in.-) wide space (M6S/M6D)

Less than 30 cm (12 in.) with 48 modules (M6S/M6D)

n Installation Base model: M6xBS

Power supplied to signal conditioners from the power supply module n

(via the installation base). Spring terminal provides constant force, eliminating torque management, maintenance- free for retightening

High-density mounting: 16 units (M6D) in a space of 9.5 cm (3.75”) n

Holding up to 48 modules of M6 Series using 6 installation bases. n

s EXTERNAL DIMENSIONS mm (inch)

A

56

Four-wire Signal Conditioners

Two-wire Signal Conditioners

Power Transducers

Indicators

Limit Alarms

Gateway,Remote I/O

Paperless RecordingSystem

PC Recorder

Electronic Actuators& Position Sensors Lightning Surge Protectors

Data sheets available on Web in PDF. Visit M-System Data Library at www.m-system.co.jp ISP1-1

Mini-M Series

Mini-MW Series

M6 Series

W5-UNIT Series

M3-UNIT Series

M3S-UNIT Series

Pico-M Series

MX-UNIT Series

M-UNIT Series

W-UNIT Series

K-UNIT Series

F-UNIT Series

H-UNIT Series

10-RACK Series

18-RACK Series

38-RACK Series Rack

-mou

nted

Four-wire Product Selection Guide

Low Profile

M5-UNIT Series

M5-UNIT Series

Four

-wire

Sig

nal C

ondi

tione

rs

Model Function PageM5SN Input Loop Powered Isolator P.57

M5VS Signal Transmitter P.57

M5MV Signal Transmitter (narrow span input) P.57

M5VF Signal Transmitter (high speed response) P.57

M5TS Thermocouple Transmitter P.58

M5RS RTD Transmitter P.58

M5MS Potentiometer Transmitter P.58

M5DY Current Loop Supply P.58

M5PT PT Transmitter P.59

M5CT CT Transmitter P.59

M5CTC CT Transmitter (clamp-on current sensor) P.59

M5PA Frequency Transmitter P.59

Construction Terminal block

Connection M3.5 screw terminals (nickel-plated steel; torque 0.8 N·m)

Housing material Flame-resistant resin (black)Isolation Input to output to power Operating temperature -5 to +55°C (23 to 131°F)Power LED Green light turns on when the power is suppliedMounting DIN railDielectric strength DC powered

AC powered

2000V AC @1 minute (input to output to power to ground)1500V AC @1 minute (input to output to power to ground)

AC power input Operational voltage range 85 – 264VDC power input Operational voltage range for 24V ±10%

s EXTERNAL DIMENSIONS s SPECIFICATIONS94

(3.70

)3 (

.12)

25 (.98) 41 (1.61) [3.3 (.13)]

• When mounting, no extra space is needed between units.

DIN RAIL35mm wide

8–M3.5 SCREW7.3 (.29)

1 2

3 4

5 6

7 8

M-System's M5 Series Transmitters are designed to accept a wide variety of process signal input and provide a standard and non-standard DC output.

Only 41 mm (1.61 in") deep modules can be ■

installed anywhere, even behind the panel cover

The M5 Series features single channel four-wire ■

models

Standard DIN rail mounting ■

2000V AC isolation (1500V AC for AC powered) ■

Selectable power input – 24V DC, 85–264V AC ■

Power indicator LED ■

mm (inch)

A

60

Four-wire Signal Conditioners

Two-wire Signal Conditioners

Power Transducers

Indicators

Limit Alarms

Gateway,Remote I/O

Paperless RecordingSystem

PC Recorder

Electronic Actuators& Position Sensors Lightning Surge Protectors

Data sheets available on Web in PDF. Visit M-System Data Library at www.m-system.co.jp ISP1-1

Mini-M Series

Mini-MW Series

M6 Series

M5-UNIT Series

M3-UNIT Series

M3S-UNIT Series

Pico-M Series

MX-UNIT Series

M-UNIT Series

W-UNIT Series

K-UNIT Series

F-UNIT Series

H-UNIT Series

10-RACK Series

18-RACK Series

38-RACK Series Rack

-mou

nted

Four-wire Product Selection Guide

W5-UNIT Series

Four

-wire

Sig

nal C

ondi

tione

rs

Low Profile Signal Splitters

W5-UNIT Series

Model Function PageW5VS Signal Transmitter P.61

W5FV Signal Transmitter (field-configurable) P.61

W5TS Thermocouple Transmitter P.61

W5RS RTD Transmitter P.62

W5MS Potentiometer Transmitter P.62

W5DY Current Loop Supply P.62

W5LCS Strain Gauge Transmitter P.63

W5PA Frequency Transmitter P.63

Construction Terminal blockConnection Input Output & Power

M3.5 screw terminalsM3 screw terminals

Housing material Flame-resistant resin (black)Isolation Input to output 1 to output 2 to powerOperating temperature -5 to +55°C (23 to 131°F)Mounting DIN rail

Dielectric strength2000V AC @1 minute (input to output 1 or output 2 to power to ground)1000V AC @1 minute (output 1 to output 2)

AC power input Operational voltage range 85 – 264V

DC power input Operational voltage range for 24V ±10%, 11 – 27V, or 85 – 150V

s EXTERNAL DIMENSIONS s SPECIFICATIONS

54321

11109876

94 (3

.70)

45 (1.77) 41 (1.61) [3.3 (.13)]

• When mounting, no extra space is needed between units.

DIN RAIL35mm wide

5–M3.5 SCREW7.4 (.29)

6–M3 SCREW

6 (.24)

3 (.12

)

Only 41 mm (1.61 in") deep modules can be ■

installed anywhere, even behind the panel cover

The W5 Series signal splitters provide two isolated ■

DC outputs of independent ranges

Standard DIN rail mounting ■

2000V AC isolation ■

Selectable power input – 11–27V DC, 85–264V AC, ■

110V DC

W5 Series Dual Output Transmitters are designed to accept a wide variety of process signal input and provide a standard and non-standard DC output.

mm (inch)

64

Two-wire Signal Conditioners

Power Transducers

Indicators

Limit Alarms

Gateway,Remote I/O

Paperless RecordingSystem

PC Recorder

Electronic Actuators& Position Sensors Lightning Surge Protectors

Data sheets available on Web in PDF. Visit M-System Data Library at www.m-system.co.jp ISP1-1

Mini-M Series

Mini-MW Series

M6 Series

M5-UNIT Series

W5-UNIT Series

M3S-UNIT Series

Pico-M Series

MX-UNIT Series

M-UNIT Series

W-UNIT Series

K-UNIT Series

F-UNIT Series

H-UNIT Series

10-RACK Series

18-RACK Series

38-RACK Series Rack

-mou

nted

Four-wire Product Selection Guide

M3-UNIT Series

Four

-wire

Sig

nal C

ondi

tione

rsFour-wire Signal Conditioners

A Thin Profile

M3-UNIT Series

Model Function PageM3LU Universal Transmitter (field- and PC-configurable) P.65

M3LV Signal Transmitter (field- and PC-configurable) P.65

M3LT Thermocouple Transmitter (field- and PC-configurable) P.66

M3LR RTD Transmitter (field- and PC-configurable) P.66

M3LM Potentiometer Transmitter (field- and PC-configurable) P.66

M3LLC Strain Gauge Transmitter (field- and PC-configurable) P.67

M3LDY Current Loop Supply (linearizing; field- and PC-configurable) P.67

M3DY Current Loop Supply P.67

M3LPA Frequency Transmitter (field- and PC-configurable) P.67

Construction Front terminal accessConnection Removable terminal blockHousing material Flame-resistant resin (grey)Isolation Input to output to power Calibration One-Step CalStatus indicator LED Tri-color (green/amber/red) LED

Operating temperature -25 to +65°C (-13 to +149°F)Max. 55°C (131°F) for UL approval

Mounting DIN rail

Dielectric strength

AC powered (M3LU): 2000V AC @1 minute (input to output to power to ground)DC powered: 1500V AC @1 minute (input to output or power to ground) 500V @1 minute (output to power)

AC power input(M3LU, M3LPA) Operational voltage range 85 – 264V AC

DC power input Operational voltage range 9 – 36V DCOperational voltage range 24V DC ±10% (M3LDY)

10 11 12

7 8 9

4 5 6

1 2 310

6 (4.1

7)

18 (.71) 110.5 (4.35)

62 (2

.44)

[5 (.20)]

• When mounting, no extra space is needed between units.

DIN RAIL35mm wide

s EXTERNAL DIMENSIONS

PC Programmable; “ONE-STEP CAL” Programming Without Needing a PC is also available.Easy and precise field configurable I/O ranges ■

Enhanced PC Configurator Software ■

1500V AC isolation ■

18 mm (0.71”) thin profile DIN rail mounting ■

s SPECIFICATIONS mm (inch)

68

Two-wire Signal Conditioners

Power Transducers

Indicators

Limit Alarms

Gateway,Remote I/O

Paperless RecordingSystem

PC Recorder

Electronic Actuators& Position Sensors Lightning Surge Protectors

Data sheets available on Web in PDF. Visit M-System Data Library at www.m-system.co.jp ISP1-1

Mini-M Series

Mini-MW Series

M6 Series

M5-UNIT Series

W5-UNIT Series

M3-UNIT Series

Pico-M Series

MX-UNIT Series

M-UNIT Series

W-UNIT Series

K-UNIT Series

F-UNIT Series

H-UNIT Series

10-RACK Series

18-RACK Series

38-RACK Series Rack

-mou

nted

Four-wire Product Selection Guide

Thin Profile

M3S-UNIT Series

M3S-UNIT Series

Four

-wire

Sig

nal C

ondi

tione

rsFour-wire Signal Conditioners

A

Model Function PageM3SYV Isolator P.69

M3SXV Signal Transmitter (PC programmable) P.69

M3SVS Signal Transmitter P.69

M3SWVS Signal Transmitter (two isolated outputs) P.70

M3SXT Thermocouple Transmitter (PC programmable) P.70

M3SXR RTD Transmitter (PC programmable) P.70

M3SRS RTD Transmitter P.71

M3SXM Potentiometer Transmitter (PC programmable) P.71

M3SMS Potentiometer Transmitter P.71

M3SDY Current Loop Supply P.71

s SPECIFICATIONS

Construction Front terminal accessConnection Removable terminal blockHousing material Flame-resistant resin (grey)

Isolation Input to output to power/ Input to output 1 to output 2 to power

Operating temperature -10 to +55°C (14 to 131°F)Mounting DIN rail

Dielectric strength 2000V AC @1 minute (input to output to power to ground)

AC power input (universal) Operational voltage range 90 – 264V

DC power input (universal) Operational voltage range for 24V DC ±10%, 21.6 – 264V DC

7 8

5 6

1 2

3 4

106 (

4.17)

12(.47)

110.5 (4.35)

62 (2

.44)

[5 (.20)]

• When mounting, no extra space is needed between units.

DIN RAIL35mm wide

s EXTERNAL DIMENSIONS

Universal AC/DC power input models available.Super-space-saving 12mm (0.47") width ■

Universal AC/DC power input available ■

PC programmable models available ■

DC input model with optional fast response time ■

mm (inch)

A

72

Four-wire Signal Conditioners

Two-wire Signal Conditioners

Power Transducers

Indicators

Limit Alarms

Gateway,Remote I/O

Paperless RecordingSystem

PC Recorder

Electronic Actuators& Position Sensors Lightning Surge Protectors

Data sheets available on Web in PDF. Visit M-System Data Library at www.m-system.co.jp ISP1-1

Mini-M Series

Mini-MW Series

M6 Series

M5-UNIT Series

W5-UNIT Series

M3-UNIT Series

M3S-UNIT Series

H-UNIT Series

10-RACK Series

18-RACK Series

38-RACK Series Rack

-mou

nted

Four-wire Product Selection Guide

Other Four-wire Signal ConditionersPico-M/ MX-UNIT/ M-UNIT/

W-UNIT/ K-UNIT/ F-UNIT Series

Pico-M Series

MX-UNIT Series

M-UNIT Series

W-UNIT Series

K-UNIT Series

F-UNIT Series

Four

-wire

Sig

nal C

ondi

tione

rs

Wide Variety of I/O ModulesUltra-small size thanks to surface-mounted compo- ■

nents with low heat generating design

4-way isolation ■

Continuously selectable input ranges ■

4–20mA 2nd output available ■

Dual Output Super-mini Signal Conditioners Pico-M Series

Local LED display indicates input in engineering unit ■

The display helps programming with the front ITEM/ ■

DATA buttons.

2000V AC isolation ■

Plug-in Front Configurable MX-UNIT Series

Field Configurable

Plug-in typeLCD display optional ■

2000V AC isolation ■

Plug-in M-UNIT Series

Two independent output ranges can be specified. ■

2000V AC isolation ■

Plug-in Signal Splitters W-UNIT Series

Plug-in signal splitters

Plug-in typeLow cost ■

Wide selection of power transducers ■

Plug-in K-UNIT Series

Zero & span adjustments behind access door ■

Space-saving Plug-in F-UNIT Series

Space-saving type

AFour-wire Signal Conditioners

Two-wire Signal Conditioners

Power Transducers

Indicators

Limit Alarms

Gateway,Remote I/O

Paperless RecordingSystem

PC Recorder

Electronic Actuators& Position Sensors

Lightning Surge Protectors

73

Mini-M Series

Mini-MW Series

M6 Series

M5-UNIT Series

W5-UNIT Series

M3-UNIT Series

M3S-UNIT Series

Pico-M Series

MX-UNIT Series

M-UNIT Series

W-UNIT Series

K-UNIT Series

F-UNIT Series

Four-wire Product Selection Guide

Specifications are subject to change without notice.ISP1-1

10-RACK Series

18-RACK Series

38-RACK Series

Other Four-wire Signal ConditionersH-UNIT/ 10-RACK/ 18-RACK/ 38-RACK Series and Others

H-UNIT Series

Four

-wire

Sig

nal C

ondi

tione

rsRa

ck-m

ounte

d

Space-saving typePneumatic transducers available ■

Space-saving Plug-in H-UNIT Series

Up to 16 units in 19-inch rack ■

Optional 40-pin connector for outputs ■

Direct interface to Various DCS via connector ■

Dual Output 10-RACK Series

One-input, two isolated outputs

Connectors compatible to various DCSUp to 16 units in 19-inch rack ■

Direct interface to Various DCS via connector ■

Dual outputs standard ■

DCS Front End 18-RACK Series

Complete packaging for interposing relays ■

Plug to plug connection controller ■

I/O simulator function ■

Interposing Relays 38-RACK Series

Greatly simplifies designing, installation, wiring and testing of interposing relays.

Accepts 100–240V AC and provides regulated ■

24V DC output (60W / 120W / 240W)

Maintenance forecast monitor function ■

DC Power Supply model: MDC5 / MDC6 / MDC7

Portable current signal generator ■

Used to perform a loop test during a maintenance, in- ■

spection or testing of an instrumentation system or plant

Generates simulated signals at the receiver side in ■

place of an on-site transmitter

Compact and light weight to fit into a pocket ■

Current Loop Checker

model: C-HCL-A