www.musterfire.com 24/7 INTEGRITY MONITORING LOWER RISK AS 5062-2016 COMPLIANT FIRE SUPPRESSION SYSTEMS MONITORING EQUIPMENT 24/7 Muster II Fire Suppression System and Fire Alarm System; offers a range of solutions to suit your applications, requirements and budget. These solutions are all designed to meet the Australian Standard 5062-2016. There are three compliant systems available: FIRE DETECTION SYSTEM ONLY; Linear heat detection with loud audible alarm, allows for fast personnel response, does not include a discharge system. MANUALLY OPERATED FIRE SUPPRESSION SYSTEM; Manual actuators connected to cylinders, includes a discharge system. Indicates when then agent is discharged. FULL AUTOMATIC AND MANUALLY OPERATED FIRE SUPPRESSION SYSTEM; includes a full detection system in either LHD or Loss of Pressure, discharge system is fully engineered to minimise risk areas on the equipment.

Transcript of FIRE SUPPRESSION SYSTEMS MONITORING EQUIPMENT 24/7 · FIRE SUPPRESSION SYSTEMS. MONITORING...

Page 1: FIRE SUPPRESSION SYSTEMS MONITORING EQUIPMENT 24/7 · FIRE SUPPRESSION SYSTEMS. MONITORING EQUIPMENT 24/7. Muster. II. Fire Suppression System and Fire Alarm System; offers a range

www.musterfire.com

24/7 INTEGRITY MONITORING LOWER RISK

AS 5062-2016 COMPLIANT

FIRE SUPPRESSION SYSTEMSMONITORING EQUIPMENT 24/7

MusterII Fire Suppression System and Fire Alarm System; offers a range of solutions to suit your applications, requirements and budget. These solutions are all designed to meet the Australian Standard 5062-2016.

There are three compliant systems available:

FIRE DETECTION SYSTEM ONLY; Linear heat detection with

loud audible alarm, allows for fast personnel response, does not

include a discharge system.

MANUALLY OPERATED FIRE SUPPRESSION SYSTEM; Manual

actuators connected to cylinders, includes a discharge system.

Indicates when then agent is discharged.

FULL AUTOMATIC AND MANUALLY OPERATED FIRE

SUPPRESSION SYSTEM; includes a full detection system

in either LHD or Loss of Pressure, discharge system is fully

engineered to minimise risk areas on the equipment.

Page 2: FIRE SUPPRESSION SYSTEMS MONITORING EQUIPMENT 24/7 · FIRE SUPPRESSION SYSTEMS. MONITORING EQUIPMENT 24/7. Muster. II. Fire Suppression System and Fire Alarm System; offers a range

MANUALLY OPERATED FIRE SUPPRESSION SYSTEM

Compliant to AS 5062-2016, Section 5.2.4

Includes:

� Manual actuating devices� Fire extinguishing agent containers/cylinders� Discharge pipe work and nozzles

Benefit of the system and what it offers:

� 24/7 monitoring of the cylinder integrity� Manual activation of discharging the extinguisher agent� Provide a signal, or other indication, confirming agent

discharge� Shut down signal for air conditioning

FIRE DETECTION SYSTEM ONLY

Compliant to AS 5062-2016, Section 5.2.5

Includes:

� Fire detectors� Fire alarm� Fire indicator panel

Benefit of the system and what it offers:

� 24/7 monitoring of the heat detection sensor� Rapid detection of a fire� Initiate an alarm signal� Initiate safety functions� Shut down signal for air conditioning

Electrical Shutdown

Manual Actuation Button

Electrical Shutdown

Page 3: FIRE SUPPRESSION SYSTEMS MONITORING EQUIPMENT 24/7 · FIRE SUPPRESSION SYSTEMS. MONITORING EQUIPMENT 24/7. Muster. II. Fire Suppression System and Fire Alarm System; offers a range

FIRE DETECTION WITH AUTOMATICALLY OR MANUALLY OPERATED FIRE SUPPRESSION SYSTEM

Compliant to AS 5062-2016, Section 5.2.3 & 5.2.2

Includes:

� Fire detectors� Fire alarm� Fire indicator panel� Fire extinguishing agent containers� Manual actuation devices� Discharge pipe work and nozzles

Benefit of the system and what it offers:

� Full 24/7 monitoring of the heat detection sensor andcylinder integrity

� Rapid detection of a fire� Initiate an alarm signal� Automatically activate discharge of extinguishing agent� Manual activation of discharge and extinguishing agent� Provide a signal or indication confirming agent discharge� Initiate safety functions� Shut down signal for air conditioning

MUSTER AGENTS; TRAINED AND ACCREDITED FOR INSTALLATION AND SERVICING

The MusterII accreditation process and fire suppression system’s holistic approach, gives the customer confidence; in their contractors, asset management and security. Ensure MusterII Systems are installed and serviced by companies displaying this shield.

Muster Agents have access to:

� Training� Fully monitored system design� Technical support

� Risk Assessments� Service log templates

Electrical Shutdown

Page 4: FIRE SUPPRESSION SYSTEMS MONITORING EQUIPMENT 24/7 · FIRE SUPPRESSION SYSTEMS. MONITORING EQUIPMENT 24/7. Muster. II. Fire Suppression System and Fire Alarm System; offers a range

MUSTERII COMPONENTS

Cylinder Valve

One valve that can be configured for either; electronic MusterWire or LOP sensing systems. Made for high durability valve body has features that improve filling and discharge speeds.

� Easy to service� Interchangeable adaptor nut

allows the valve to be retrofitted to many cylinder brands

� High level of accuracy whileminimising the chance of falsedischarge

Cylinder and Cylinder Brackets

Constructed to AS 2470 the cylinders and brackets are 304 grade Stainless Steel, and completed in a UV stabilised powder coated finish.

� Silicone liner reducing vibration and wear� Vibration eliminator mounts available� Heavy duty welded cylinder brackets have

been designed to minimize space usage

MusterCapTM and Nozzles

Nozzles must be protected to reduce the chance of contaminants. MusterII nozzles come with MusterCaps™ offering a tight tongue and groove seal on the nozzle face reducing the chance of the cap vibrating off.

� Quick discharge feature that ensures thenozzle ejects the cap fast and effectively

� UV stabilised and chemical resistant� Never seize or corrode onto the nozzle� Stainless steel 120° and 60° nozzles

available

Digital Pressure Gauge

The gauge has its own battery power supply and can be mounted remotely for greater monitoring, greater range of measurement and gives accurate cylinder pressure within 0.05%.

� Long 7 year battery life� State of the art transducers� Highly accurate reading, with easy

to read display

Alarm Panel

The MusterII system offers one Alarm Panel that can be configured for either; electronic MusterWire or LOP sensing systems. Easy to read but does not obstruct the view for the driver.

� Powered by a totally independent batterysupply which can last up to 2 years

� Monitors nitrogen pressure every second� Data, telemetry and auxiliary options

available such as historical datadownload, audio, additional circuit

Diagnostic Module

Features an easy to read backlit LCD screen and simple to follow navigation, it will allow for fast and accurate assessment of your MusterII Fire Suppression System

� Tests the system pressure andbattery status

� Show detailed information onsystem faults

� Update software, reset andisolate the alarm panel

Unit 1, 21 Amour St Revesby NSW 2212

PO Box 333 Milperra NSW 2214

Ph: (02) 9914 8720 Fax: (02) 9914 8798

Email: [email protected]

Every effort has been made to ensure all information and photographs contained in this publication were correct and accurate at time of printing, however no warranty is given in respect of this publication and JSG Industrial Systems Pty Ltd (JSG) shall not be liable for any error therein. Technical information, specifications and products shown may be subject to change without prior notice. Pictures shown are for illustration purposes only. WARNING: For sale and proper use consult instructions, the supplier or JSG. Contact your nearest JSG Distributor for latest information.