Main Power Supply: 24 VDC (± 4)
Backup Power Supply: 24 VDC (± 4)
Power Supply Protection: 5 Amp
Power Consumption: 0.5 Amp
Connection:
Cable Entries: 4 x 20 mm cable glands
Max Wire Size: 12 AWG (2.05 mm)
Dimensions (mm): 255(w) x 180(h) x 61(d)
Dimensions (in): 10(w) x 7(h) x 2.4(d)
Weight: 1 kg
Enclosure Materials: Polycarbonate Plastic
FIRE DETECTION & ALARM - FIRESTOPSea-Fire Marine “FireStop” is a USCG approved conventional fire detection system that provides quick and clear identification of fire alarms and events.
The Fire Control Panel (FCP) features a weather resistant monitoring system with fire, heat and smoke monitoring capability.
Designed for the increasing sophistication of modern vessels in the commercial and recreational marine market, this innovative accessory compliments Sea-Fire’s fire suppression product offering to meet the aesthetic value of intuitive operation and increased safety onboard.
The detection system is the ultimate economical choice for the commercial and recreational marine industry.
Part Number131-501 Fire Stop Fire Control Panel
Electrical Specifications Mechanical Specifications
WWW.SEA-FIRE.COMVisit our website
WWW.SEA-FIRE.COMVisit our website
FunctionsFire and failure detection: fault (open or short circuit).
Inputs/Outputs • CAT5 port for receiving and sending signals
to the Display Panel (PN: 131-933) and Zone Identification Panel (ZIP) (PN: 131-529 (gray) or 131-548 (black)).
• Display Panel and ZIP Push Button (Reset and Silencing of the Alarm)
• NAC Alarm Output: 2 amp max
• Adapter Unit Reset Relay: Qty. 1 rated @ 16 Amps
System Capacity • Standard 2 zone system (Accommodation and Engine Room)
• Zone Capacity: 2 detectors and/or manual call points per zone
• Expandable to 4 zones per Adapter Unit (PN: 131-520) and up to 16 zones per Zip Panel (PN: 131-548/529)
• Compatible with Hochiki marine detectors and accessories
Protection Level: Ingress Protection 66 (IP66)
Operating Requirements: -25°C to 70°C, -13°F to 158°F
Mounting: Surface Mount
SEA-FIRE MARINE9331-A Philadelphia Rd.
Baltimore, MD 21237 USAPH: +1(410) 687-5500FX: +1(410) 687-5503
24VDC Main Supply24VDC Backup Supply
Control Panel PN: 131-501
Silence Enable Switch PN: 131-909
Display Panel PN: 131-933
Zone Identification Panel PN: 131-529
Cat
5 C
able
Cat
5
Cab
le
Heat Detector PN: 130-821Adapter UnitPN:131-520
Smoke Detector PN: 130-822
Manual Pull Station PN: 131-923
Horn Strobe PN: 124-125
Conforms to UL864.
Environmental Protection
Cat 5 Cable