FINESTION-2003-2006 a complete dataset of routine air ion measurements 2003 – 2006 in co-operation...

28
FINESTION-2003-2006 a complete dataset of routine air ion measurements 2003 – 2006 [email protected] in co-operation with: Urmas Hõrrak, Kaupo Komsaare, Pasi P. Aalto, Petri Keronen, and Sander Mirme Pühajärve 2007

description

Amount of data diurnal records, mostly 24×6 = 144 measurements per day (some variables 48 or 24 measurements per day). Total about 40×10 6 values ( inlc. less than 10% of missing codes ). Unzipped file bytes, about 3.8 bytes per value, Zipped file 52 megabytes, about 1.4 bytes per value. Format: DD (DataDiurna) diary.

Transcript of FINESTION-2003-2006 a complete dataset of routine air ion measurements 2003 – 2006 in co-operation...

Page 1: FINESTION-2003-2006 a complete dataset of routine air ion measurements 2003 – 2006 in co-operation with: Urmas Hõrrak, Kaupo Komsaare,

FINESTION-2003-2006a complete dataset of

routine air ion measurements 2003 – [email protected]

in co-operation with: Urmas Hõrrak, Kaupo Komsaare,

Pasi P. Aalto, Petri Keronen, and Sander Mirme

Pühajärve 2007

Page 2: FINESTION-2003-2006 a complete dataset of routine air ion measurements 2003 – 2006 in co-operation with: Urmas Hõrrak, Kaupo Komsaare,

What is included?Tahkuse Hyytiälä Tartu

Instrument Tahkuse AIS BSMA1 BSMA2From 23.07.2003 20.03.2003 02.04.2004

To 31.12.2006 31.12.2006 31.12.2006

Meteo T, Tground, p, RH, wind, W/m2

T, Tgrad, p, RH, UV, wind, prec, W/m2, visibility

T, p, RH, wind, prec, lux, W/m2

Chemistry NOx,SO2,O3 Dose rate

Mobility 0.00065–2.74 0.036–2.74 0.036–2.74Size 0.5–65 nm 0.5–6.5 nm 0.5–6.5 nm

Neutral aerosols are not presented in the distribution version of the dataset

Page 3: FINESTION-2003-2006 a complete dataset of routine air ion measurements 2003 – 2006 in co-operation with: Urmas Hõrrak, Kaupo Komsaare,

Amount of data

283 164 diurnal records, mostly 24×6 = 144 measurements per day (some variables 48 or 24 measurements per day) .

Total about 40×106 values (inlc. less than 10% of missing codes).

Unzipped file 146 958 411 bytes, about 3.8 bytes per value,

Zipped file 52 megabytes, about 1.4 bytes per value.

Format: DD (DataDiurna) diary.

Page 4: FINESTION-2003-2006 a complete dataset of routine air ion measurements 2003 – 2006 in co-operation with: Urmas Hõrrak, Kaupo Komsaare,

Preprocessing of dataBSMA (single-channel scanning) data: The records with BSMA noise index ≥ 50 were deleted as unreliable

(about 15% of measurements was lost in Hyytiälä and 16% in Tartu).

The measurements made with a period of 15 min were converted to the10-minute period using interpolation by means of the DD data manager.

The values of RH% recorded by BSMA were corrected so that the nighttime maximums do not exceed 100%.

The fraction concentrations were converted to the values of distribution functions dn / d(log d) and dn / d(log Z) assigned to the centers of the fractions in the logarithmic scale of diameter or mobility.

The indices of technical diagnostics were replaced with the integral parameters: cluster ion concentration (Z > 0.56 cm2V−1s−1), intermediate ion concentration (Z = 0.032 − 0.56 cm2V−1s−1), cluster ion average mobility and air polar conductivity.

Page 5: FINESTION-2003-2006 a complete dataset of routine air ion measurements 2003 – 2006 in co-operation with: Urmas Hõrrak, Kaupo Komsaare,

Tahkuse AIS (multichannel instrument) data: The physically unbelievable measurements were marked as missing.

The records with too many missing measurements were deleted .

The measurements recorded every 5 minutes were converted to the time step of 10 minutes.

If a missing value was located between known values then the gap was filled using a sophisticated interpolation method.

The data was complemented with the integral parameters: cluster ion (Z > 0.56 cm2V−1s−1), intermediate ion (Z = 0.032 − 0.56 cm2V−1s−1), and large ion (Z = 0.0006 − 0.032 cm2V−1s−1) concentrations; cluster ion average mobility and air polar conductivity.

The data was transformed to the dn / d(log d) and dn / d(log Z) values so that a decade is logarithmically uniformly divided into 8 fractions. Thus the first 16 fractions are just the same as in the BSMA measurements.The mobility was converted to the particle size considering the measurements of air pressure and temperature.

Page 6: FINESTION-2003-2006 a complete dataset of routine air ion measurements 2003 – 2006 in co-operation with: Urmas Hõrrak, Kaupo Komsaare,

Included quantitiesSymbol Quantity

T:C Air temperature near the stationTg:C Ground temperature near the stationTgr:K/m Gradient of temperatureTc:C Chimney temperature near the stationRH% Relative humidityP:mb Air pressure near the stationWind:m/s Wind velocity at standard heightWmax:m/s Wind 5-minute maximum at standard heightWind:deg Wind directionPrec:mm/h Precipitation intensityIllum:lux Solar illuminanceRad:W/m2 Total insolation sun+skyUVB:W/m2 UV radiation 310-320 nmVis:km Visibility DR:uSv/h Gamma radiation dose rateNOx:ug/m3 Concentration of NOx (1 ppb is converted to 191 ug/cm3)SO2:ug/m3 Concentration of SO2 (1 ppb is converted to 2.66 ug/cm3)O3:ug/m3 Concentration of O3 (1 ppb is converted to 2.0 ug/cm3)

Page 7: FINESTION-2003-2006 a complete dataset of routine air ion measurements 2003 – 2006 in co-operation with: Urmas Hõrrak, Kaupo Komsaare,

Symbol Unit Quantity

B-noise cm-3 BSMA noise indexRC+ cm-3 Tahkuse index of spectra roughness for positive clustersRN+ cm-3 Tahkuse index of spectra roughness for positive nanoparticlesRP+ cm-3 Tahkuse index of spectra roughness for positive particlesRC- cm-3 Tahkuse index of spectra roughness for negative clustersRN- cm-3 Tahkuse index of spectra roughness for negative nanoparticlesRP- cm-3 Tahkuse index of spectra roughness for negative particles

NC+:cm-3 1/cm3 Concentration of positive cluster ions (Z > 0.5 cm2/Vs)NC-:cm-3 1/cm3 Concentration of negative cluster ions (Z > 0.5 cm2/Vs)NN+:cm-3 1/cm3 Concentration of positive nanometer ions (Z = 0.03-0.5 cm2/Vs)NN-:cm-3 1/cm3 Concentration of negative nanometer ions (Z = 0.03-0.5 cm2/Vs)NP+:cm-3 1/cm3 Concentration of positive particle ions (Z = 0.0003-0.03 cm2/Vs)NP-:cm-3 1/cm3 Concentration of negative particle ions (Z = 0.0003-0.03 cm2/Vs)ZC+cm cm2/Vs Average mobility of positive cluster ions (Z > 0.5 cm2/Vs)ZC-cm cm2/Vs Average mobility of negative cluster ions (Z > 0.5 cm2/Vs)L+:fS/m fS/m Positive conductivity of airL-:fS/m fS/m Negative conductivity of air

Page 8: FINESTION-2003-2006 a complete dataset of routine air ion measurements 2003 – 2006 in co-operation with: Urmas Hõrrak, Kaupo Komsaare,

z+01 cm-3 dN/d(log Z) of positive ions at Z = 2.74 cm2/Vsz+02 cm-3 dN/d(log Z) of positive ions at Z = 2.05 cm2/Vsz+03 cm-3 dN/d(log Z) of positive ions at Z = 1.54 cm2/Vsz+04 cm-3 dN/d(log Z) of positive ions at Z = 1.15 cm2/Vsz+05 cm-3 dN/d(log Z) of positive ions at Z = 0.87 cm2/Vsz+06 cm-3 dN/d(log Z) of positive ions at Z = 0.65 cm2/Vsz+07 cm-3 dN/d(log Z) of positive ions at Z = 0.487 cm2/Vsz+08 cm-3 dN/d(log Z) of positive ions at Z = 0.365 cm2/Vsz+09 cm-3 dN/d(log Z) of positive ions at Z = 0.274 cm2/Vsz+10 cm-3 dN/d(log Z) of positive ions at Z = 0.205 cm2/Vsz+11 cm-3 dN/d(log Z) of positive ions at Z = 0.164 cm2/Vsz+12 cm-3 dN/d(log Z) of positive ions at Z = 0.115 cm2/Vsz+13 cm-3 dN/d(log Z) of positive ions at Z = 0.0866 cm2/Vsz+14 cm-3 dN/d(log Z) of positive ions at Z = 0.0649 cm2/Vsz+15 cm-3 dN/d(log Z) of positive ions at Z = 0.0487 cm2/Vsz+16 cm-3 dN/d(log Z) of positive ions at Z = 0.0365 cm2/Vs

z+17 cm-3 dN/d(log Z) of positive ions at Z = 0.0274 cm2/Vsz+18 cm-3 dN/d(log Z) of positive ions at Z = 0.0205 cm2/Vsz+19 cm-3 dN/d(log Z) of positive ions at Z = 0.0154 cm2/Vsz+20 cm-3 dN/d(log Z) of positive ions at Z = 0.0115 cm2/Vsz+21 cm-3 dN/d(log Z) of positive ions at Z = 0.0087 cm2/Vsz+22 cm-3 dN/d(log Z) of positive ions at Z = 0.0065 cm2/Vsz+23 cm-3 dN/d(log Z) of positive ions at Z = 0.00487 cm2/Vsz+24 cm-3 dN/d(log Z) of positive ions at Z = 0.00365 cm2/Vsz+25 cm-3 dN/d(log Z) of positive ions at Z = 0.00274 cm2/Vsz+26 cm-3 dN/d(log Z) of positive ions at Z = 0.00205 cm2/Vsz+27 cm-3 dN/d(log Z) of positive ions at Z = 0.00154 cm2/Vsz+28 cm-3 dN/d(log Z) of positive ions at Z = 0.00115 cm2/Vsz+29 cm-3 dN/d(log Z) of positive ions at Z = 0.00087 cm2/Vsz+30 cm-3 dN/d(log Z) of positive ions at Z = 0.00065 cm2/Vs

Page 9: FINESTION-2003-2006 a complete dataset of routine air ion measurements 2003 – 2006 in co-operation with: Urmas Hõrrak, Kaupo Komsaare,

d+01 cm-3 dN/d(log D) of positive ions at D = 0.49 nmd+02 cm-3 dN/d(log D) of positive ions at D = 0.65 nmd+03 cm-3 dN/d(log D) of positive ions at D = 0.87 nmd+04 cm-3 dN/d(log D) of positive ions at D = 1.15 nmd+05 cm-3 dN/d(log D) of positive ions at D = 1.54 nmd+06 cm-3 dN/d(log D) of positive ions at D = 2.05 nmd+07 cm-3 dN/d(log D) of positive ions at D = 2.74 nmd+08 cm-3 dN/d(log D) of positive ions at D = 3.65 nmd+09 cm-3 dN/d(log D) of positive ions at D = 4.87 nmd+10 cm-3 dN/d(log D) of positive ions at D = 6.49 nm

d+11 cm-3 dN/d(log D) of positive ions at D = 8.66 nmd+12 cm-3 dN/d(log D) of positive ions at D = 11.6 nmd+13 cm-3 dN/d(log D) of positive ions at D = 15.4 nmd+14 cm-3 dN/d(log D) of positive ions at D = 20.5 nmd+15 cm-3 dN/d(log D) of positive ions at D = 27.4 nmd+16 cm-3 dN/d(log D) of positive ions at D = 36.5 nmd+17 cm-3 dN/d(log D) of positive ions at D = 48.7 nmd+18 cm-3 dN/d(log D) of positive ions at D = 65.0 nm

Page 10: FINESTION-2003-2006 a complete dataset of routine air ion measurements 2003 – 2006 in co-operation with: Urmas Hõrrak, Kaupo Komsaare,

STATISTICS

Page 11: FINESTION-2003-2006 a complete dataset of routine air ion measurements 2003 – 2006 in co-operation with: Urmas Hõrrak, Kaupo Komsaare,

Station Quantity Days Min Ave Max Sigma

Hyyt NC+:cm-3 1298 27 737.9 1788 225.3Hyyt NC-:cm-3 1298 -481 721.3 2383 239.8Hyyt NN+:cm-3 1285 -869 16.4 1032 47.1Hyyt NN-:cm-3 1285 -804 21.5 6046 93.9Hyyt ZC+cm 1298 0.85 1.445 2.04 0.139Hyyt ZC-cm 1298 0.94 1.638 2.24 0.155

Tartu NC+:cm-3 750 -143 397.1 1618 175.6Tartu NC-:cm-3 750 -164 303.4 4317 160.3Tartu NN+:cm-3 745 -997 30.1 1933 88.9Tartu NN-:cm-3 745 -880 36.9 7421 121Tartu ZC+cm 750 0.02 1.434 2.59 0.086Tartu ZC-cm 750 0.12 1.581 3.6 0.122

Tahk NC+:cm-3 1103 0 436.4 1200 161.2Tahk NC-:cm-3 1100 0 370.3 1200 153.7Tahk NN+:cm-3 1103 -30 114.4 1199 117.1Tahk NN-:cm-3 1102 -30 98.5 1199 136.1Tahk NP+:cm-3 1102 0 1371.5 8982 819Tahk NP-:cm-3 1103 0 1389.8 8984 830.6Tahk ZC+cm 1100 0.6 1.419 2.1 0.081Tahk ZC-cm 1094 0.6 1.563 2.08 0.113

Page 12: FINESTION-2003-2006 a complete dataset of routine air ion measurements 2003 – 2006 in co-operation with: Urmas Hõrrak, Kaupo Komsaare,

Station Quantity Days Min Ave Max Sigma

Hyyt d-01 1298 -1565 1293.9 4952 568.7Hyyt d-02 1298 -7720 1974.9 6060 603.4Hyyt d-03 1298 -741 1730.7 10912 813.3Hyyt d-04 1298 -1085 707.7 4857 628.8Hyyt d-05 1298 -1186 93.4 6824 182.6Hyyt d-06 1298 -816 37.0 11016 193.0Hyyt d-07 1298 -2376 37.4 11344 207.3Hyyt d-08 1298 -3160 28.0 7784 157.8Hyyt d-09 1298 -4504 19.8 7560 157.7Hyyt d-10 1298 -5568 15.6 10200 282.7

Tartu d-01 750 -384 580.9 5936 280.7Tartu d-02 750 -72 640.1 6296 305.4Tartu d-03 750 -640 693.5 7192 375.1Tartu d-04 750 -672 424.9 9240 328.5Tartu d-05 750 -1248 135.5 12776 209.7Tartu d-06 750 -1240 46.9 16576 202.5Tartu d-07 750 -3640 41.4 14312 198.3Tartu d-08 750 -3904 43.3 9536 191.1Tartu d-09 750 -6800 50.3 7360 259.2Tartu d-10 750 -8000 51.0 14272 475.6

Page 13: FINESTION-2003-2006 a complete dataset of routine air ion measurements 2003 – 2006 in co-operation with: Urmas Hõrrak, Kaupo Komsaare,

Station Quantity Days Min Ave Max Sigma

Tahk d-01 1100 -563 507.7 2372 230.0Tahk d-02 1100 -531 929.2 3592 382.2Tahk d-03 1100 -448 888.5 3512 404.0Tahk d-04 1100 -900 395.8 3919 279.4Tahk d-05 1103 -416 187.2 10461 289.1Tahk d-06 1102 -679 149.3 2812 188.4Tahk d-07 1102 -503 76.4 2501 121.0Tahk d-08 1102 -840 98.3 2489 158.6Tahk d-09 1102 -792 152.2 3082 246.5Tahk d-10 1102 -852 223.0 3741 371.1Tahk d-11 1103 -991 318.5 13703 576.1Tahk d-12 1103 -894 423.0 10357 431.1Tahk d-13 1103 -827 650.3 11369 501.1Tahk d-14 1103 -962 995.1 13466 677.6Tahk d-15 1103 -955 1464.8 19793 978.2Tahk d-16 1103 -951 2286.7 18459 1426.4Tahk d-17 1103 -845 3111.7 28679 2021.9Tahk d-18 1103 0 3893.4 40320 2866.8

Page 14: FINESTION-2003-2006 a complete dataset of routine air ion measurements 2003 – 2006 in co-operation with: Urmas Hõrrak, Kaupo Komsaare,

Average size distribution of negative ions

0

500

1000

1500

2000

2500

3000

3500

0.1 1 10 100Air ion diameter : nm

dn /

d lo

g d

Hyytiälä

Tartu

Tahkuse

Page 15: FINESTION-2003-2006 a complete dataset of routine air ion measurements 2003 – 2006 in co-operation with: Urmas Hõrrak, Kaupo Komsaare,

Average size distribution of negative ions

0

500

1000

1500

2000

0.5 1.5 2.5 3.5 4.5 5.5 6.5Air ion diameter : nm

dn /

d lo

g d

Hyytiälä

Tartu

Tahkuse

Page 16: FINESTION-2003-2006 a complete dataset of routine air ion measurements 2003 – 2006 in co-operation with: Urmas Hõrrak, Kaupo Komsaare,

How to use?

Empty folders

Page 17: FINESTION-2003-2006 a complete dataset of routine air ion measurements 2003 – 2006 in co-operation with: Urmas Hõrrak, Kaupo Komsaare,

delimiter (tab)

how many headerlinestolerable

percent of errors

time pattern

base year

time shift from UT, s(Helsinki winter time)variable name

in table

quantity name in diary

station

time regime

code of amissing value

factor table/diary

Page 18: FINESTION-2003-2006 a complete dataset of routine air ion measurements 2003 – 2006 in co-operation with: Urmas Hõrrak, Kaupo Komsaare,

Double-click

Result

Page 19: FINESTION-2003-2006 a complete dataset of routine air ion measurements 2003 – 2006 in co-operation with: Urmas Hõrrak, Kaupo Komsaare,
Page 20: FINESTION-2003-2006 a complete dataset of routine air ion measurements 2003 – 2006 in co-operation with: Urmas Hõrrak, Kaupo Komsaare,

delimiter (tab)

how many headerlinestolerable

percent of errors

time pattern

base year

time shift (s)(Helsinki winter time)variable name

in table

quantity name in diary

station

time regime

missing code

factor table/diary

Page 21: FINESTION-2003-2006 a complete dataset of routine air ion measurements 2003 – 2006 in co-operation with: Urmas Hõrrak, Kaupo Komsaare,

Why DataDiurna?A rectangular table can be conveniently processed and analyzed with common software like MS Excel (if the number of rows < 65536).

Different quantities are often saved with different time steps and many cells in a tectangular table will be empty. If a table holds a large complex dataset then it is composed mostly of the missing value codes like –999.

An alternative is a set of different tables joined into a database. Common database systems, e.g. MS Access, are optimized for the business applications. The time structure and the specifity of environmental measurements is not sufficiently exploited in these systems.

Another alternative is the diary format well known in hand-written measurement records. This alternative is applied in DataDiurna, which is optimized for managing of environmental measurements.

An additional advantage: the rules of DataDiurna force the user to include minimum explanations into the dataset, e.g. the data cannot be saved without indicating how much the time is shifted from UT.

Page 22: FINESTION-2003-2006 a complete dataset of routine air ion measurements 2003 – 2006 in co-operation with: Urmas Hõrrak, Kaupo Komsaare,

A source table

NB: DataDiurna is not a replacement for Excel1) to manage large data: choose DataDiurna,2) to analyze the tables: choose Statistica, Excel, etc.

Asourcetable

Asourcetable

Commondiary

Anoutlettable

Anoutlettable

Page 23: FINESTION-2003-2006 a complete dataset of routine air ion measurements 2003 – 2006 in co-operation with: Urmas Hõrrak, Kaupo Komsaare,

Excerpt from a diary:20041110,Tartu.m,Rad:W/

m2,hm,2,2,2,2,2,2,7,20,28,32,39,33,18,8,2,2,2,2,2,2,2,2,2,2

20041110,Tartu.m,Wind:m/s,hm,3.8,3.8,3.9,4.4,4.9,4.9,4.4,2.4,1.8,1.8,2.5,2.1,2,1.9,0.7,1.7,2,1.5,2,1,1.2,1.1,1.3,1.1

20041111,Hyyt,L+:fS/m,m10,9.6,9.1,8.7,8.9,9.1,9.4,10.2,9.8,9.6,10.3,10.9,11.4,11.6,12.2,12.5,11.8,11.9,12.2,12.7,12.5,12.1,11.9,11.3,11,11.6,11.5,11.3,10.9,11.2,11.5,11.5,11.3,11,10.7,11.1,11.5,11.1,11,,,,10.1,10.1,10,9.9,10.1,10.2,10.2,10,10.3,10.8,11.4,11.2,11.1,11.4,11.4,11.3,11.2,11.7,12,11.5,12.2,12.9,12.7,12.9,13.1,13.1,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,

20041111,Hyyt,Rad:W/m2,m30,0,0,0,0,0,0,0,0,0,0,0,0,1,1,2,3,5,4,7,15,24,23,24,28,15,10,3,1,0,0,0,0,0,0,-1,0,0,0,0,0,0,-1,-1,0,0,0,0,0

Date

Station

QuantityTime regime

Here are missing data

Page 24: FINESTION-2003-2006 a complete dataset of routine air ion measurements 2003 – 2006 in co-operation with: Urmas Hõrrak, Kaupo Komsaare,

DataDiurna is omnivorous:The time stamp and the numbers can be written as you data provider likes, e.g. following data rows, where the time stamp is highlighted, are considered equal

Time 13:25 Date 21.05.2005 23.1,-17,?,1.6e-19,2783597+003

2005-05-21 13:25:00,23.1,-17,x,1.60-19,0.2783597e3

DOY=141.559, measurements: +23.10 -17 -999 278.3597

20050521132500) 23.1;-17;-999;2,783,597e-4

The time is automatically converted into UT when importing a source table to the diary and to any time zone when exporting an output table from the diary.

The rows of the source table may be non-uniformly distributed in time: DataDiurna can interpolate and average the data during the import and export.

The code of missing value may be individual for every variable and may be numerical (e.g. –999) or non-numerical (e.g. ?).

etc... etc... etc...

.......

Warning: The data manager DD2007T.exe is still a beta-version.

Page 25: FINESTION-2003-2006 a complete dataset of routine air ion measurements 2003 – 2006 in co-operation with: Urmas Hõrrak, Kaupo Komsaare,

The basic version of the datasetFINESTION-2003-2006

was composed froma large number of source tables

with different time stepsfrom 10 minutes to 1 hour

Page 26: FINESTION-2003-2006 a complete dataset of routine air ion measurements 2003 – 2006 in co-operation with: Urmas Hõrrak, Kaupo Komsaare,

The working version of the datasetFINESTION-2003-2006

is located in the computerof the user

Thus:Every user can create extended personal version of the dataset

importing additional private data

Page 27: FINESTION-2003-2006 a complete dataset of routine air ion measurements 2003 – 2006 in co-operation with: Urmas Hõrrak, Kaupo Komsaare,

How to get?The DataDiurna data manager is free for unlimited distribution.

The dataset ATMEL2007A is free for unlimited distribution.

Both they can be retrieved from the page:

http://ael.physic.ut.ee/tammet/dd/The dataset FINESTION-2003-2006 is free but available only for our research group. It is not published in Internet today. Thus:

Ask the memory stick or the CD with the dataset and copy the folder DD into your own computer.

NB: You should have 200 MB free on your hard disk.

Page 28: FINESTION-2003-2006 a complete dataset of routine air ion measurements 2003 – 2006 in co-operation with: Urmas Hõrrak, Kaupo Komsaare,

Thank youfor choosing

DataDiurna.....hard to learn but easy to use

when managing large complex datasets like

FINESTION-2003-2006