NDT of fiber-reinforced composites with a new laser-ultrasound system
Guided By:Prof Arun JMechanical Eng Department
Presented By:Aaron K JohnMechanical Engineering
![Page 2: Final Year Seminar](https://reader031.fdocuments.net/reader031/viewer/2022022419/58830e531a28ab31068b4e7d/html5/thumbnails/2.jpg)
Introduction
• Non contact method• Currently no non-contact NDT method approaches the
sensitivity of contact NDT method• Methods:
non-contact NDT: Michelson Interferometernew non contact NDT: LU Interferometercontact NDT: Piezoelectric Transducer
![Page 3: Final Year Seminar](https://reader031.fdocuments.net/reader031/viewer/2022022419/58830e531a28ab31068b4e7d/html5/thumbnails/3.jpg)
About seminar
In this new approach we utilize recent
progress in fiber laser systems andtelecommunication optics to improve thesensitivity of non-contact method
![Page 4: Final Year Seminar](https://reader031.fdocuments.net/reader031/viewer/2022022419/58830e531a28ab31068b4e7d/html5/thumbnails/4.jpg)
Current non contact methodMichelson Interferometer
• Combine laser beams to obtain interference pattern, to measure surface defects etc.
• Very sensitive to environmental noise
![Page 5: Final Year Seminar](https://reader031.fdocuments.net/reader031/viewer/2022022419/58830e531a28ab31068b4e7d/html5/thumbnails/5.jpg)
Experiment Samples
• 3.6 mm thick andcontained 19 individuallayers.
• Artificial defects ofabout 20um thick
- brass foil- tape- polymer
![Page 6: Final Year Seminar](https://reader031.fdocuments.net/reader031/viewer/2022022419/58830e531a28ab31068b4e7d/html5/thumbnails/6.jpg)
New laser-ultrasound method
Experiment components
1. Pulsed laser source2. Super luminescent diode (SLD)3. Polarization controller4. Receive Head5. Polarizing Beam splitters (PBS)6. Photo Detector (PD)
Interferometer
![Page 7: Final Year Seminar](https://reader031.fdocuments.net/reader031/viewer/2022022419/58830e531a28ab31068b4e7d/html5/thumbnails/7.jpg)
1. laser radiation initially polarized
2.Divided into two arms with a polarization beam splitter PBS1
3.PBS2 combines the delayed beams into one fiber
4.focuses the probe radiation onto the sample surface5.Radiation back to the fiber contains 2 delayed waves, similar to incident beams
6.beams are split again to reduce noise
EXPERIMENT ARRANGMENT AND PROCEDURE
![Page 8: Final Year Seminar](https://reader031.fdocuments.net/reader031/viewer/2022022419/58830e531a28ab31068b4e7d/html5/thumbnails/8.jpg)
• When no pulsed laser present, interferometerrecords nothing• But when pulsed laser present, acoustic pulsegenerated, interferometer records the pressuredifference
![Page 9: Final Year Seminar](https://reader031.fdocuments.net/reader031/viewer/2022022419/58830e531a28ab31068b4e7d/html5/thumbnails/9.jpg)
Experiment with PVDF Transducer
• Polyvinylidene Fluoride (PVDF)• A type of piezoelectric transducer
![Page 10: Final Year Seminar](https://reader031.fdocuments.net/reader031/viewer/2022022419/58830e531a28ab31068b4e7d/html5/thumbnails/10.jpg)
Results
Signals recorded with LU (grey line) and with contactPVDF (dark line)
Result 1.
![Page 11: Final Year Seminar](https://reader031.fdocuments.net/reader031/viewer/2022022419/58830e531a28ab31068b4e7d/html5/thumbnails/11.jpg)
image obtained with Interferometer
Result 2.
Image obtained with contact PVDF detector
![Page 12: Final Year Seminar](https://reader031.fdocuments.net/reader031/viewer/2022022419/58830e531a28ab31068b4e7d/html5/thumbnails/12.jpg)
Inference
1. From Result 1 we infer that the sensitivity ofthe non contact LU detector is comparable tothat of a contact piezoelectric transducer.
2. From Result 2 PVDF transducer is about oneorder of magnitude more sensitive than theSagnac detector. Hence we infer LU detectorin comparable to a piezoelectric transducer
![Page 13: Final Year Seminar](https://reader031.fdocuments.net/reader031/viewer/2022022419/58830e531a28ab31068b4e7d/html5/thumbnails/13.jpg)
Conclusions
The new laser ultrasound
- is a non contact method
- does not need adjustment and stabilization
- can be mounted on any surface
- less expensive
![Page 14: Final Year Seminar](https://reader031.fdocuments.net/reader031/viewer/2022022419/58830e531a28ab31068b4e7d/html5/thumbnails/14.jpg)
Reference
1. National Center for BiotechnologyInformation (USA)
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3971821/
2. NDT of fiber reinforced composites with anew fiber optic pump probe laser ultrasoundsystem. (Science Direct)