Fiberprofil Americas-Gfrp presentation

34
[email protected] 1–888–99–REBAR(73227) 5522 – 36 Street Edmonton, Alberta T6B 3P3 T:780 – 448 – 9338 F:780 – 448 – 9338

description

GFRP Rebar presentation

Transcript of Fiberprofil Americas-Gfrp presentation

Page 1: Fiberprofil Americas-Gfrp presentation

[email protected]–888–99–REBAR(73227)

5522 – 36 StreetEdmonton, AlbertaT6B 3P3T:780 – 448 – 9338 F:780 – 448 – 9338

Page 2: Fiberprofil Americas-Gfrp presentation

Romans are the pioneers of the concrete revolution. Their structures have lasted close to 2000 years.

In 1995, Intelligent Sensing for Innovative Structures (ISIS) was formed by the Federal Government to investigate the crumbling infrastructure of North America.

Today’s Steel-reinforced concrete will begin to deteriorate after 10 to 15 years and will generally require major repairs after 25 years.

Page 3: Fiberprofil Americas-Gfrp presentation
Page 4: Fiberprofil Americas-Gfrp presentation

Rust Staining, Business Entryway, Edmonton, AB

STAGE 1BLEEDING

Page 5: Fiberprofil Americas-Gfrp presentation

De-lamination Cracking, 19 Year Old Ontario Bridge, MTO 2005

STAGE 2CRACKING

Page 6: Fiberprofil Americas-Gfrp presentation

Corrosion Induced Cracking, 23 Yr Old Ontario Bridge, MTO 2007

STAGE 3SPALLING

Page 7: Fiberprofil Americas-Gfrp presentation

Chloride Induced Corrosion, Roof of 13 Year Old Swimming Pool Collapses, Switzerland

STAGE 4FAILURE

Page 8: Fiberprofil Americas-Gfrp presentation

• In 1997, Dywidag-Systems International contacted BP Automation/Brandstrom Engineering Ltd. to develop a threaded fibreglass rebar system.

• In 1999, the company developed threaded fibreglass manufacturing equipment.

• In 2000, BP Composites Ltd. was formed to supply DSI and the mining industry with fibreglass rebar and rock bolts.

Page 9: Fiberprofil Americas-Gfrp presentation

• In 2006, ISIS Canada developed a Product Specification Manual for GFRP reinforcement for civil application.

• BP Composites Ltd. adjusted and expanded their GFRP process to create a family of rebar sizes suitable for concrete reinforcement.

Page 10: Fiberprofil Americas-Gfrp presentation

• ISIS Canada developed...• Canada

- CAN/CSA-S606 (2006) Fibre Reinforced Structures, “Canadian Highway Bridge Design Code” Canadian Standards Association, pp.693-728

- CAN/CSA-S806-02 (R2007) “Design and Construction of Building Components with Fibre-Reinforced Polymers” Canadian Standards Association

Page 11: Fiberprofil Americas-Gfrp presentation

• USA- ACI 440.1R-06 (2006) “Guide for the Design and

Construction of Structural Concrete Reinforced with FRP Bars”, American Concrete Institute

- AASHTO GFRP-1 (2009) “AASHTO LFRD Bridge Design Guide Specifications for GFRP-Reinforced Concrete Bridge Decks and Traffic Railings”, American Association of State Highway and Transportation Officials

Page 12: Fiberprofil Americas-Gfrp presentation

• Material Code Requirements for GFRP rebar:- Vinyl Ester Resin- E type fibreglass - or E-CR fibreglass (Corrosion Resistant)

Page 13: Fiberprofil Americas-Gfrp presentation

• Mechanical Properties1. Cross-Sectional Area2. Longitudinal Tensile Strength for Bars3. Longitudinal Tensile Modulus and Ultimate Elongation4. Bond Strength5. Transverse Shear Strength6. Strength of FRP Bent Bars7. Longitudinal Tensile Strength and Modulus of FRP Bent

Bars8. Longitudinal Tensile Properties at Cold Temperature9. Flexural Strength and Modulus

Page 14: Fiberprofil Americas-Gfrp presentation

• Physical Properties1. Fibre Content2. Longitudinal Coefficient of Thermal Expansion3. Transverse Coefficient of Thermal Expansion4. Density5. Void Content6. Water Absorption7. Cure Ratio8. Glass Transition Temperature

Page 15: Fiberprofil Americas-Gfrp presentation

• Durability Properties1. Alkali Resistance in High pH Solution (No Load)2. Alkali Resistance in High pH Solution (Load)3. Creep Rupture Strength4. Creep (10,000 Hr Test)

Page 16: Fiberprofil Americas-Gfrp presentation

• Rigorous testing has concluded:- 100+ Year Life Expectancy for GFRP Reinforced

Structures.

Page 17: Fiberprofil Americas-Gfrp presentation

• TUF-BAR™ tested in accordance with- ISIS Product Certification of FRP Materials guideline- CAN/CSA-S806-02 (R2007) “Design and Construction of

Building Components with Fibre-Reinforced Polymers”- CAN/CSA-S606 (2006) Fibre Reinforced Structures,

“Canadian Highway Bridge Design Code”, pp.693-728- ACI 440.3R-04 (2004) “Guide Test Methods for Fiber-

Reinforced Polymers (FRPs) for Reinforcing or Strengthening Concrete Structures”

- AASHTO GFRP-1 (2009) “AASHTO LFRD Bridge Design Guide Specifications for GFRP-Reinforced Concrete Bridge Decks and Traffic Railings”,

Page 18: Fiberprofil Americas-Gfrp presentation
Page 19: Fiberprofil Americas-Gfrp presentation
Page 20: Fiberprofil Americas-Gfrp presentation
Page 21: Fiberprofil Americas-Gfrp presentation
Page 22: Fiberprofil Americas-Gfrp presentation
Page 23: Fiberprofil Americas-Gfrp presentation

• Features- Impervious to Chloride-Ion

and Chemical Attack- ¼ Weight of Steel- 2x Tensile Strength of Steel- Thermal Isolator- Non-Conductive- Non-Magnetic- Sizes #2-#8, 6mm-25mm- Standard/Custom Lengths,

Shapes, Bends

Page 24: Fiberprofil Americas-Gfrp presentation

Black Steel Stainless Steel TUF-BAR ™

Price 10x Black Steel Equivalent to Galvanized

Corrosion Susceptible Susceptible Non-Susceptible

Weight 1/4 of Steel

Tensile Strength 2x Steel/Stainless

Modulus 200 GPa 200 GPa 40-60 GPa

Bond Strength 8-11 MPa 8-11 MPa 10-16 MPa

Thermal Conductivity Yes Yes No

Electrical Conductivity

Yes Yes No

Magnetic Yes No No

Page 25: Fiberprofil Americas-Gfrp presentation

• Canada Green Building Council Member• Green Alberta Evaluation No. 09-004-V01• TUF-BAR™ is 100% recyclable• TUF-BAR™ contributes:

- 6 LEED® Credits in Canada- 7 LEED® Credits in USA

Page 26: Fiberprofil Americas-Gfrp presentation

• Glass Creep- GFRP not recommended:

- Pre-Tensioning- Post-Tensioning- Dead Loads

• Modulus- Cantilevering Loads

• Elongation- GFRP Elongates Linearly 2%

Page 27: Fiberprofil Americas-Gfrp presentation

• High Embedment Strength- Rough Surface- Sand Coating

• Fatigue- 20x Longer Under Cyclic

Loads

• Minimal Concrete Cover

Page 28: Fiberprofil Americas-Gfrp presentation

Loading FixtureA. El-Ragaby , E. F. El-Salakawy and B. Benmokrane

Page 29: Fiberprofil Americas-Gfrp presentation

• Low Risk Profile• Lightweight • Cuts with Chop Saw or Grinding Disc (No Shears)• Vinyl Coated Tie Wire or Zip Ties• No Patching or Corrosion Treatment

Page 30: Fiberprofil Americas-Gfrp presentation

• Studied in 12 Countries and 70 Universities• Extensive Canadian Studies involving 22

Researchers and 14 Universities

Page 31: Fiberprofil Americas-Gfrp presentation

• Researchers conclude 100+ Year Life Expectancy for GFRP Reinforced Structures:

1.No Degradation in GFRP Reinforcement2.Excellent Bonding3.No Debonding4.No Microcracking5.No Voids6.No Resin Microcracking7.No Glass Fibre Degradation8.No Significant Delamination/Debonding9.No Glass Transition10.No Sign of Chemical Degradation of the Resin11.No Chemical Degradation (Hydrolysis)

Page 32: Fiberprofil Americas-Gfrp presentation

• Composites Innovation Centre University of Manitoba

• GFRP 70% cost savings over 100 years

Page 33: Fiberprofil Americas-Gfrp presentation

• Research Teams Recommend:That GFRP be allowed as the Primary Reinforcement

• CAN/CSA-S6-06 (2006) “Canadian Highway Bridge Code”, pg.693-728

• CAN/CSA-S806-02 (R2007) “Design and Constructions of Building Components with Fibre-Reinforced Polymers”

• “If you look at the full life cycle cost, GFRP is far more cost-effective than metallic reinforcement”

Dr. Brahim BenmokraneNSERC Industry Research Chair

Page 34: Fiberprofil Americas-Gfrp presentation

• BP Composites Ltd.• (T): 780-448-9338• (F): 780-448-9360• 1-888-99-REBAR(73227)• [email protected]