FIBER OPTICS AND DATA COMMUNICATIONrosenberger.co.kr/data/(카탈로그) FTTA-Fiber to the... ·...

105
FIBER OPTICS AND DATA COMMUNICATION solution for wireless cellular sites and network www.rosenberger.com www.rosenbergerap.com

Transcript of FIBER OPTICS AND DATA COMMUNICATIONrosenberger.co.kr/data/(카탈로그) FTTA-Fiber to the... ·...

Page 1: FIBER OPTICS AND DATA COMMUNICATIONrosenberger.co.kr/data/(카탈로그) FTTA-Fiber to the... · 2016-12-31 · FIBER OPTICS AND DATA COMMUNICATION solution for wireless cellular

FIBER OPTICS AND DATA COMMUNICATIONsolution for wireless cellular sites and network

www.rosenberger.comwww.rosenbergerap.com

Page 2: FIBER OPTICS AND DATA COMMUNICATIONrosenberger.co.kr/data/(카탈로그) FTTA-Fiber to the... · 2016-12-31 · FIBER OPTICS AND DATA COMMUNICATION solution for wireless cellular

22

INTRODUCTION

Rosenberger Hochfrequenztechnik GmbH&Co. was founded in Germany in 1958 and ranks among the leading manufacturers of high-speed interconnect solutions worldwide. To serve the continuous growth and demand of the global market, Rosenberger Asia Pacific Electronic Co., Ltd. was established in China in 1997. With its long tradition of excellence and providing creative solutions, Rosenberger Asia Pacific has excelled and earned an outstanding reputation in the Asia Pacific region.

Rosenberger Asia Pacific provides products and solutions for Telecommunication, Automotive Electronics, Information Technology, Test & Measurement, Aviation, and Medical & Industries.

A sales network covering the entire Asia Pacific region generates an annual turnover close to 300 million USD. Reliability and competitiveness are the cornerstones of this sustainable growth, resulting in long term partnerships with most of the leading companies in their respective industries.

Rosenberger HQ, Bavaria, Germany

Page 3: FIBER OPTICS AND DATA COMMUNICATIONrosenberger.co.kr/data/(카탈로그) FTTA-Fiber to the... · 2016-12-31 · FIBER OPTICS AND DATA COMMUNICATION solution for wireless cellular

3

.

Rosenberger Asia Pacific maintains 6 modern manufacturing and R&D base locations in Beijing, Shanghai, Kunshan and Dongguan in China as well as Haryana & GOA in India, the largest of its kind in the Asia Pacific Region. Rosenberger Asia Pacific is an ISO 9001 quality system, ISO 14001 environmental system, and ISO/TS 16949 automotive industry system certified company. Equipped with advanced machining, electronic plating, cable manufacturing, assembly and testing centers and staffed with more then 200 R&D engineers, Rosenberger Asia Pacific has developed the first class production assembly lines and exercises stringent product and quality control.

Presently, Rosenberger Asia Pacific maintains a far reaching network of R&D, Production, Sales and Service which extends to the whole Asia Pacific and Middle East region. For over 55 years Rosenberger has established its brand and reputation all over the world. Moving forward, Rosenberger Asia Pacific will continue to provide excellent product solutions and services for its customers in the entire region.

Rosenberger Asia Pacific: A: Beijing, China− Headquarters, R&D and Production

B: GOA, India − R&D and Production

C: Guangdong Dongguan, China − R&D and Production

D: Haryana, India − R&D and Production

E: Jiangsu Kunshan, China − R&D and Production

F: Shanghai Pudong, China − R&D and Production

A

B

C

D

E

F

Page 4: FIBER OPTICS AND DATA COMMUNICATIONrosenberger.co.kr/data/(카탈로그) FTTA-Fiber to the... · 2016-12-31 · FIBER OPTICS AND DATA COMMUNICATION solution for wireless cellular

4

MISSION STATEMENT

CORE VALUE

• Design, manufacture and deploy total solutions for telecommunication networks worldwide• Create value for our customers through innovative products, customized services and cost effective solutions• Maintain the highest quality standards, state-of-the-art manufacturing facilities and employ reliable supply chain

management to achieve and exceed customer expectations• Be socially responsible to our community and environment • Be committed to employee's personnel development

• Value Innovation• Customer Focus• Sustainable Growth• Social Responsibility

Page 5: FIBER OPTICS AND DATA COMMUNICATIONrosenberger.co.kr/data/(카탈로그) FTTA-Fiber to the... · 2016-12-31 · FIBER OPTICS AND DATA COMMUNICATION solution for wireless cellular

5

PRODUCTPORTFOLIOS

Base Station Antenna Feeder SystemsWireless Coverage SolutionsMicrowave Backhaul SolutionsRF Connectivity SolutionsPassive Intermodulation Measurement SystemsFTTA Fiber Optic Site SolutionsFTTx-ODN Passive Network SolutionsFiber Optic Connectivity SolutionsLow Frequency Cables and ComponentsNetwork Optimization Services

Premise Network Cabling ProductsData Center/Cloud Computing SolutionsIntelligent Infrastructure Management System

RF Test CablesRF Precision ConnectorsCalibration KitsAccessories and Tools

FAKRA Connectors and Cable AssembliesHSD® SystemHVR® High Voltage ConnectorsRoPD® Power Data Connectors

Non-Magnetic RF Connectors Non-Magnetic RF Cable AssembliesData/RF/Power/DC Hybrid Connectors and AssembliesCustomized Data/Power Connectivity SystemFiber Optic Connectivity Products

Telecommunication System Solutions

IT/Data Communication

Test and Measurement

Automotive Electronics

Medical & Industries

Page 6: FIBER OPTICS AND DATA COMMUNICATIONrosenberger.co.kr/data/(카탈로그) FTTA-Fiber to the... · 2016-12-31 · FIBER OPTICS AND DATA COMMUNICATION solution for wireless cellular

6

+

+

+

+

+

+

++

+

+1991-2014

+

Remote radio head (RRH) has become one of the most important subsystems of today and tomorrow's distributed wireless infrastructure. Remote radio head has operation and management processing capabilities and it has standardized or customized optical, power, data and RF interfaces for connecting to the rest of wireless radio network. The evolution and deployment of remote radio systems significantly improve the network bandwidth and performance while at the same time reduce energy consumption. The ubiquitous data explosion continues today in the every place and every second which demands the upgrades or new deployments of 3G and 4G-LTE network infrastructure by applying remote radio technology. Rosenberger is committed to develop and supply the most reliable fiber optic, power and data cabling infrastructures for fiber-to-the-antenna (FTTA) and power-to-the-antenna (PTTA) as well as the communication network requirements.

The New Generation of FTTA CablingThis becomes effective in streamlining operations when replacing traditional base station equipment with RRHs or upgrading a site to support RRHs. There is a huge demand for high-speed data transfer in today’s global mobile telecommunication networks. Fiber-feeder remote radio technology offers potential savings in both capital expenditure (CAPEX) and operating expense (OPEX) reductions compared with traditional coaxial cable based solutions. The connectivity and cable performance between the base station and RRH/antenna is essential for maintaining the quality of service between the networks and end users. A single hybrid cable provides multiple fiber and copper transmission lines. This is a clear advantage as it consolidates space and provides room for growth for additional RRHs besides many other benefits. Rosenberger EasyLinkTM hybrid solution benefits telecommunication operators with innovative interconnect technology which can meet the next-generation mobile network requirements.

Telecommunication Office Interconnect Solution The network performance is also assured by having a more reliable, high bandwidth and low latency switching and transmission system. Software defined networking (SDN) and radio (SDR) equipment and new silicon photonics technology require high quality interconnect solutions particularly the fiber optic connectivity and cable assemblies, in addition to traditional copper solutions. Rosenberger is sophisticated in offering both copper and fiber optic interconnect products in all available bandwidths and interfaces, which are designed and manufactured for achieving the optimum performance mechanically, environmentally and in the way of transmission. The Rosenberger passive interconnect cable products are compatible to all communication equipment vendor products and supports the future upgradability of active equipment.

Leading Connectivity and Cable ProductsNot only Rosenberger supplies the industry-standard connectivity products both fiber optics and copper, but also the specialized 2-fiber Rosenberger Duplex Connector (RDC), 4-fiber Rosenberger Quad Connector (RQC), 12/24-fber Rosenberger Multi-fiber Connector (RMCTM) and Rosenberger Fiber Enclosure (RFE) the field installable IP67 waterproof kit have been developed for realizing today and tomorrow’s high density FTTA cabling, smart-grid and industrial cabling applications in harsh environment. Rosenberger Cable Systems designs and manufacturers standard and customized fiber optic cables according to the highest quality standards both IEC and Telecordia. UL and/or Anatel certified cable are able to be fulfilled together with monkey-bite design for certain local market requirements.

The Advanced Fiber Optics and Data Communication Solutionfor today and tomorrow’s wireless cellular sites and network

Page 7: FIBER OPTICS AND DATA COMMUNICATIONrosenberger.co.kr/data/(카탈로그) FTTA-Fiber to the... · 2016-12-31 · FIBER OPTICS AND DATA COMMUNICATION solution for wireless cellular

77

+

+

+

+

+

+

++

+

+1991-2014

+

Page 8: FIBER OPTICS AND DATA COMMUNICATIONrosenberger.co.kr/data/(카탈로그) FTTA-Fiber to the... · 2016-12-31 · FIBER OPTICS AND DATA COMMUNICATION solution for wireless cellular

7

Page 9: FIBER OPTICS AND DATA COMMUNICATIONrosenberger.co.kr/data/(카탈로그) FTTA-Fiber to the... · 2016-12-31 · FIBER OPTICS AND DATA COMMUNICATION solution for wireless cellular

8

Superior QualityThe quality of our products and services is an essential part of our corporate strategy. Rosenberger’s quality philosophy is not just to optimize components and products, but to continuously improve and optimize all processes to ensure customer satisfaction: from product development, planning, purchasing, production, sales, logistics and service to environmental policy – all in all, to offer maximum benefit to our customers all over the world.

Responsibility for quality also means being proactive in protecting our environment and natural resources. We endeavour to avoid or minimize environmental pollution – even beyond the requirements of legal regulations whenever possible.

Rosenberger is certified according to ISO/TS 16949, ISO 9001 and ISO 14001

Environmental DirectivesConnectors and cable assemblies manufactured by Rosenberger correspond to the following Directives:• 2011/65/EU - Restriction of the use of certain Hazardous Substances in electrical and electronic equipment (RoHS)• 2012/19/EU - Waste Electrical and Electronic Equipment (WEEE)

The objective of the above mentioned European Directives is to avoid or to limit the use of the following hazardous substances:• Lead• Mercury• Cadmium• Chrome VI• PBB (Polybrominated Biphenyls)• PBDE (Polybrominated Diphenyl Ethers)

Page 10: FIBER OPTICS AND DATA COMMUNICATIONrosenberger.co.kr/data/(카탈로그) FTTA-Fiber to the... · 2016-12-31 · FIBER OPTICS AND DATA COMMUNICATION solution for wireless cellular

9

Content

Introduction ............................................... 2

Discrete FTTA Solution ...........................10FTTA Cable Assembly E Series .......................................... 11FTTA Cable Assembly H Series .........................................13FTTA Cable Assembly N Series .........................................15FTTA Cable Assembly S Series ..........................................17

Pre-terminated Trunk FTTA Solution ...... 19RDC Trunk Solution ............................................................20RQC Trunk Solution............................................................21LC Trunk Solution ...............................................................22

EasyLinkTM FTTA Hybrid Solution ...........23EasyLinkTM RDC Hybrid Solution ........................................24EasyLinkTM RDC Hybrid Trunk Cable .................................25EasyLinkTM RQC Hybrid Solution........................................27EasyLinkTM RQC Hybrid Trunk Cable .................................28EasyLinkTM RMCTM Hybrid Solution ....................................30EasyLinkTM RMCTM Hybrid Trunk Cable ..............................31EasyLinkTM LC Hybrid Solution ...........................................33EasyLinkTM LC Hybrid Cable Assembly ..............................34

RRH Jumper ...........................................35RDC Fiber Jumper..............................................................36RQC Fiber Jumper ............................................................37RMCTM Fiber Jumper ..........................................................38 Hybrid Jumper ....................................................................39

Distribution Box ......................................41Fiber Distribution Box .........................................................42Power Distribution Box .......................................................43Hybrid Distribution Box .......................................................44

Installation Accessory .............................45Cable Clamp .......................................................................46Grounding Kits ....................................................................47Hoisting Grips .....................................................................47

Fiber Optic Interconnect Products ..........48Patchcord & Pigtail .............................................................49Fiber Patch Panel ...............................................................51High Density VelaTM Modular Fiber Patch Panel ................52

Copper Connectivity Solution ................. 53D-Sub Series Cable Assembly ...........................................54RJ45 Ethernet Cable Assembly ..........................................55Customized Assembly ........................................................58Ethernet Patch Panel..........................................................60Balun Panel ........................................................................63LSA Module and Distribution Unit .......................................66

Power Cable Assembly........................... 69Indoor D-sub Type High Power Cable Assembly ................70Indoor ET 2 Pole Power Cable Assembly ...........................71Outdoor IP67 Power Cable Assembly ................................72Outdoor IP65 Power Cable Assembly ................................73

Fiber Optic Connectivity .........................74Rosenberger Multi-fiber Connector (RMCTM) ......................75Rosenberger Quad Connector (RQC) ................................76Rosenberger Duplex Connector (RDC) ..............................77Rosenberger Effcient Connector (REC) .............................78LC Loopback Connector .....................................................79LC Connector .....................................................................80SC Connector .....................................................................81MU Connector ....................................................................82E2000TM Connector.............................................................83Rosenberger Fiber Enclosure (RFE) ..................................84

Rosenberger Cable Systems.................. 85Quality and Environment ....................................................86Buffered Fiber .....................................................................90Simplex Fiber Optic Cable ..................................................92Duplex Fiber Optic Cable ...................................................94Distribution Fiber Optic Cable.............................................96Breakout Fiber Optic Cable ................................................98Distribution Fiber Optic Cable for FTTA ............................100Armored Fiber Optic Cable for FTTA ................................101Breakout Fiber Optic Cable for FTTA ...............................102

Page 11: FIBER OPTICS AND DATA COMMUNICATIONrosenberger.co.kr/data/(카탈로그) FTTA-Fiber to the... · 2016-12-31 · FIBER OPTICS AND DATA COMMUNICATION solution for wireless cellular

10

Discrete FTTA SolutionRosenberger discrete FTTA solution supports all kinds of cellular radio site installation scenario whatever the re-mote radio heads (RRH) are collocated on top of tower or distributed on rooftop of a building. Rosenberger has developed and manufactured various fiber optic connectors such as RDC, RQC, RMCTM, RFE for harsh environ-ment applications, fiber optic cables as well as cable assemblies with most stringent quality standards for remote radio network systems. Rosenberger has been the close partners of the major radio equipment manufacturers worldwide for many years by providing the world-leading Fiber-To-The-Antenna technologies and solutions.

Page 12: FIBER OPTICS AND DATA COMMUNICATIONrosenberger.co.kr/data/(카탈로그) FTTA-Fiber to the... · 2016-12-31 · FIBER OPTICS AND DATA COMMUNICATION solution for wireless cellular

11

FTTA Cable Assembly E Series

DescriptionThis FTTA cable assembly is designed for connecting the Main Unit (MU) and the E Series of Radio Remote Head (RRH).

SpecificationProfile/Outline

Feature and Benefit• Good for all common 3G/4G-LTE radio systems• IP67 ruggedized and compact cable divider• IP67 classed RFE for RRH connection• 100% factory assembled and tested

• Plug-and-play installation• Armored cable for monkey-bite and anti-rodent protection• UL(OFNR) and Anatel certified cable available on request• Customized cable and cable assembly available on request

Type A

AB A

B

Side A Side B

Type B Side A Side B

Type C Side A

Side B

AB

AB

Type D Side A

Side B

AB

Type E

Side ASide B

AB

AB

Page 13: FIBER OPTICS AND DATA COMMUNICATIONrosenberger.co.kr/data/(카탈로그) FTTA-Fiber to the... · 2016-12-31 · FIBER OPTICS AND DATA COMMUNICATION solution for wireless cellular

12

Mechanical and Optical Property

Type A Type B Type C Type D Type E Type F Type GConnector

Side A LCD, SMLCD (c/w RFE),

SMLCD (c/w RFE),

SMLCD (c/w RFE),

SMLCD, SM

LCD (c/w RFE), SM

LCD (c/w RFE), SM

Side B LCD, SMLCD (c/w RFE),

SMLCD, SM LCD, SM LCD, SM

LCD (c/w RFE), SM

LCD, SM

Fiber Optic CableFiber Type Single-mode according to ITU-T G.657A2, IEC 60793-2-10Fiber Count 2 fibers 2 fibers 4 fibers 2 fibers 2 fibers 2 fibers 2 fibersCable Diameter 4.8mm 4.8mm 5.0mm 4.8mm 4.8mm 4.8mm 4.8mmJacket Material LSZHArmor Protection No No NO NO YES YES YESMin. Bending Radius (Static)

20mm 20mm 60mm 20mm 20mm 20mm 20mm

Min. Bending Radius (Dynamic)

30mm 30mm 100mm 30mm 30mm 30mm 30mm

Max. Tension Strength (Long-Term)

300N 300N 300N 300N 300N 300N 300N

Max. Tension Strength (Short-Term)

450N 450N 400N 450N 450N 450N 450N

Cursh Resistance 3000N/10cm 3000N/10cm 2000N/10cm 3000N/10cm 7000N/10cm 7000N/10cm 7000N/10cmFlame Resistance IEC 60332-1, IEC 60332-3-24, UL 1666 (optional)

Smoke and Halogen Emission

IEC 60754-2, IEC 61034-2

UV Resistance Yes Yes Yes Yes Yes Yes Yes

Environmental Data

Temperature Range Operation -40 °C to +80 °CTemperature Range Storage -40 °C to +80 °CTemperature Range Installation -20 °C to +60 °C2011/65/EU(RoHS) Compliant

Packing and Delivery

L ≤100 m 1 pc in a bagL >100 m 1 pc on cardboard/wooden drum

Type F

Side BSide A

AB

Type G

Side BSide A

Page 14: FIBER OPTICS AND DATA COMMUNICATIONrosenberger.co.kr/data/(카탈로그) FTTA-Fiber to the... · 2016-12-31 · FIBER OPTICS AND DATA COMMUNICATION solution for wireless cellular

13

DescriptionThis FTTA cable assembly is designed for connecting the Main Unit (MU) and the H Series of Radio Remote Head (RRH).

FTTA Cable Assembly H Series

SpecificationProfile/Outline

Feature and Benefit:• Good for all common 3G/4G-LTE radio systems• IP67 ruggedized and compact cable divider• 100% factory assembled and tested• Plug-and-play installation

• Armored branch cable for anti-rodent protection and bird-proof• UL(OFNR) certified cable available on request• Customized cable and cable assembly available on request

1B

1A

2B

2A

Type A

Side BSide A

2A

1B

1A

2B

Type B

Side BSide A

0B

0A

1B

1A

0A

0B

1A

1B

Type C Side BSide A

Page 15: FIBER OPTICS AND DATA COMMUNICATIONrosenberger.co.kr/data/(카탈로그) FTTA-Fiber to the... · 2016-12-31 · FIBER OPTICS AND DATA COMMUNICATION solution for wireless cellular

14

Mechanical and Optical Property

Type A Type B Type C Type DConnector

Side A LCD LCD 2*LCD 2*LCDSide B LCD 2*FC 2*LCD 4*FCArmored fan-out tube

Side A Yes Yes Yes YesSide B Yes No Yes NoFiber Optic Cable

Fiber Type G652D, G657A2, OM2 or OM3 according to ITU-T standard Fiber Count 2 fibers 2 fibers 4 fibers 4 fibersCable Diameter 7.0mm 7.0mm 7.0mm 7.0mmJacket Material LSZHArmor Protection No No No NoMin. Bending Radius (Static)

70mm 70mm 70mm 70mm

Min. Bending Radius (Dynamic)

140mm 140mm 140mm 140mm

Max. Tension Strength (Long-Term)

200N 200N 200N 200N

Max. Tension Strength (Short-Term)

400N 400N 400N 400N

Crush Resistance 2200N/10cm 2200N/10cm 2200N/10cm 2200N/10cmFlame Resistance IEC 60332-1, IEC 60332-3-24, UL 1666 (optional)Smoke and Halogen Emission

IEC 60754-2, IEC 61034-2

UV Resistance Yes Yes Yes Yes

Environmental Data

Temperature Range Operation -40 °C to +80 °C

Temperature Range Storage -40 °C to +80 °C

Temperature Range Installation -20 °C to +60 °C

2011/65/EU(RoHS) Compliant

Packing and Delivery

L ≤40 m 1 pc in a bag

L >40 m 1 pc on cardboard/wooden drum

0B

0A

1B

1A

1B

1A

Type D Side B

Side A

Page 16: FIBER OPTICS AND DATA COMMUNICATIONrosenberger.co.kr/data/(카탈로그) FTTA-Fiber to the... · 2016-12-31 · FIBER OPTICS AND DATA COMMUNICATION solution for wireless cellular

15

DescriptionThis FTTA cable assembly is designed for connecting the Main Unit (MU) and the N Series of Radio Remote Head (RRH).

FTTA Cable Assembly N Series

SpecificationProfile/Outline

Feature and Benefit• Good for all common 3G/4G-LTE radio systems• IP67 classed IP seal boot for RRH connection• 100% factory assembled and tested• Plug-and-play installation

• Standard or flexible (FLEX) connector boot• UL(OFNR) certified cable available on request• Customized cable and cable assembly available on request

Type A Side B

Side A

Type B

Side BSide A

A B

BA

Type CSide BSide A

Page 17: FIBER OPTICS AND DATA COMMUNICATIONrosenberger.co.kr/data/(카탈로그) FTTA-Fiber to the... · 2016-12-31 · FIBER OPTICS AND DATA COMMUNICATION solution for wireless cellular

16

Mechanical and Optical Property

Type A Type B Type C Type D Type E

Connector

Side A LC SM(90°) LC SM(Flex) LCD SM(90°) LCD SM(Flex) LCD SM

Side B LC SM(90°) LC SM(Flex) LCD SM LCD SM(Flex) LCD SM

Fiber Optic Cable

Fiber Type G652D/G657A G657A2 G657A2 G657A2 G652D

Fiber Count 1 fiber 1 fiber 2 fibers 2 fibers 4 fibers

Cable Diameter 5.0mm 5.0mm 5.0mm 5.0mm 5.2mm

Jacket Material PVC PVC PVC PVC LSZH

Armor Protection No No No No No

Min. Bending Radius (Static) 50mm 50mm 50mm 50mm 50mmMin. Bending Radius (Dynamic)

75mm 75mm 75mm 75mm 75mm

Max. Tension Strength(Long-Term)

600N 600N 600N 600N 600N

Max. Tension Strength(Short-Term)

1200N 1200N 1200N 1200N 1200N

Cursh Resistance 7500N/10cm 7500N/10cm 7500N/10cm 7500N/10cm 7500N/10cm

Flame Resistance IEC 60332-1, IEC 60332-3-24, UL 1666 (optional)

Smoke and Halogen Emission IEC 60754-2, IEC 61034-2 (optional)

UV Resistance Yes Yes Yes Yes Yes

Environmental Data

Temperature Range Operation -40 °C to +80 °C

Temperature Range Storage -40 °C to +80 °C

Temperature Range Installation -20 °C to +60 °C

2011/65/EU(RoHS) Compliant

Packing and Delivery

L ≤100 m 1 pc in a bag

L >100 m 1 pc on cardboard drum

B

A

AB

A B

AB

Type D

Side BSide A

AB

AB

AB

AB

Type E

Side BSide A

Page 18: FIBER OPTICS AND DATA COMMUNICATIONrosenberger.co.kr/data/(카탈로그) FTTA-Fiber to the... · 2016-12-31 · FIBER OPTICS AND DATA COMMUNICATION solution for wireless cellular

17

FTTA Cable Assembly S Series

SpecificationProfile/Outline

DescriptionThis FTTA cable assembly is designed for connecting the Main Unit (MU) and the S Series of Radio Remote Head (RRH).

Feature and Benefit• Good for all common 3G/4G-LTE radio systems• IP67 ruggedized and compact cable divider• 100% factory assembled and tested• Armored cable for monkey-bite and anti-rodent protection

• Plug-and-play installation• UL(OFNR) certified cable available on request• Customized cable and cable assembly available on request

DURX

RUTX

RX

TX

Grounding kitType ASide BSide A

A

Grounding Kit

TX

RX

DU

Type B

Side BSide A

A TX

RX

DU

Type CSide BSide A

Page 19: FIBER OPTICS AND DATA COMMUNICATIONrosenberger.co.kr/data/(카탈로그) FTTA-Fiber to the... · 2016-12-31 · FIBER OPTICS AND DATA COMMUNICATION solution for wireless cellular

18

Mechanical and Optical Property

Type A Type B Type CConnector

Side A 2*LC, SM LCD(c/w PDLC03J-02) SM LCD(c/w PDLC03J-01) SM

Side B 2*LC, SM 2*LC, SM 2*LC, SM

Fiber Optic Cable

Fiber Type G652D G657B3 G657B3

Fiber Count 2 fibers 2 fibers 2 fibers

Cable Diameter 4.8mm 4.8mm 6.3mm

Jacket Material LSZH LSZH LSZH

Armor Protection Yes Yes NO

Min. Bending Radius (Static) 50mm 50mm 60mm

Min. Bending Radius (Dynamic) 100mm 100mm 120mm

Max. Tension Strength (Long-Term) 300N 300N 600N

Max. Tension Strength (Short-Term) 450N 450N 1500N

Cursh Resistance 7000N/10cm 7000N/10cm 3000N/10cm

Flame Resistance IEC 60332-1, IEC 60332-3-24, UL 1666 (optional)

Smoke and Halogen Emission IEC 60754-2, IEC 61034-2

UV Resistance Yes Yes Yes

Environmental Data

Temperature Range Operation -40 °C to +80 °C

Temperature Range Storage -40 °C to +80 °C

Temperature Range Installation -20 °C to +60 °C

2011/65/EU(RoHS) Compliant

Packing and Delivery

L ≤100 m 1 pc in a bag

L >100 m 1 pc on cardboard drum

Page 20: FIBER OPTICS AND DATA COMMUNICATIONrosenberger.co.kr/data/(카탈로그) FTTA-Fiber to the... · 2016-12-31 · FIBER OPTICS AND DATA COMMUNICATION solution for wireless cellular

19

The FTTA trunk solution utilizes one fiber cable trunk with 3 to 18 pairs / channels of optical fiber connecting base stations and remote radio heads (RRH) in wireless communication network, with or without a FTTA distribution box. One trunk can provide fiber for supporting up to 18 RRHs. Developing a fiber cable trunk system provides the fiber needed for today and future network growth requirements. All Rosenberger trunk fiber cables assemblies are 100% factory assembled and tested with performance guaranteed. Fiber optic jumpers with standard fiber optic LC connector interface are used in conjunction with Rosenberger FTTA trunk system.

Pre-terminated Trunk FTTA Solution

Page 21: FIBER OPTICS AND DATA COMMUNICATIONrosenberger.co.kr/data/(카탈로그) FTTA-Fiber to the... · 2016-12-31 · FIBER OPTICS AND DATA COMMUNICATION solution for wireless cellular

20

RDC Trunk Solution

Feature and Benefit • Up to 24 fibers• IP67 robust and compact divider • IP67 RDC connectors for water immersion and dust protection• Plug-and-play installation

Specification

Description2-fiber RDC (Rosenberger Duplex Connector) trunk is an innovativesolution with multi-fibers in a single cable to simply the RRH deployments. The trunk is designed with slim dividers which split multi-fibers into individual outdoor cables. The trunk cables are terminated with IP67-rated RDC connectors. Different types of jumpers are available to allow connection between the trunk cable

and any vendor-specific hardware interface. Trunk Solution is the good choice for operators who lease space on tower cell sites. It reduces annual leasing costs by reducing the space utilized on the tower. Plug-and-Play connections minimize installation time and require no tools.

• Reduced tower loading and leasing costs• Terminated with RDC in top breakout to connect with RRH by matching RDC fiber jumpers

Trunk Cable

12 fibers 24 fibersSide A (Top) 6*RDC 12*RDCSide B (Bottom) 6*LC duplex 12*LC duplexBreakout Cable Length 600mm, 700mm, 800mmCable Retention Force (Fiber Breakout) 200NCable Retention Force (Trunk Cable) 1000NCable Bending Radius Min. (Installation) 10 times the cable diameterCable Bending Radius Min. (Operation) 20 times the cable diameterOuter Diameter Nominal 6.2 ± 0.3mm 8.5 ± 0.5mmJacket Material LSZHFiber Type G657A, OM2, OM3Flammability IEC 60332-12011/65/EU(RoHS) CompliantTemperature Range -40°C ~ +70°CPacking Wood board drum

Length±Tolerance

Key

A-ABA

BA

BA

Length±Tolerance

Key

A-ABA

BA

BA

Profile/Outline12 fibers RDC - LCD

24 fibers RDC - LCD

Page 22: FIBER OPTICS AND DATA COMMUNICATIONrosenberger.co.kr/data/(카탈로그) FTTA-Fiber to the... · 2016-12-31 · FIBER OPTICS AND DATA COMMUNICATION solution for wireless cellular

21

Feature and Benefit • Up to 24 fibers• IP67 robust and compact divider • IP67 RQC connectors for water immersion and dust protection• Plug-and-play installation

Length±Tolerance

BA

BA

key

1A1B2A2B

Length±Tolerance

BA

BA

key

1A1B2A2B

RQC Trunk Solution

Description4-fiber RQC (Rosenberger Quad Connector) trunk is an innovative solution with multi-fibers in a single cable to simply the RRH deployments. The trunk is designed with slim dividers which split multi-fibers into individual outdoor cables. The trunk cables are terminated with IP67-rated RQC connectors. Different types of jumpers are available to allow connection between the trunk cable

and any vendor-specific hardware interface. Trunk Solution is the good choice for operators who lease space on tower cell sites. It reduces annual leasing costs by reducing the space utilized on the tower. Plug-and-Play connections minimize installation time and require no tools.

Specification

• Reduced tower loading and leasing costs• Terminated with RQC in top breakout to connect with RRU by

matching RQC fiber jumpers

Trunk cable

12 fibers 24 fibersSide A (Top) 3*RQC 6*RQCSide B (Bottom) 6*LC duplex 12*LC duplexBreakout Cable Length 600mm, 700mm, 800mmCable Retention Force (Fiber Breakout) 200NCable Retention Force (Trunk Cable) 1000NCable Bending Radius Min. (Installation) 10 times the cable diameterCable Bending Radius Min. (Operation) 20 times the cable diameterOuter Diameter Nominal 6.2 ± 0.3mm 8.5 ± 0.5mmJacket Material LSZHFiber Type G657A, OM2, OM3Flammability IEC 60332-12011/65/EU(RoHS) CompliantTemperature Range -40°C ~ +70°CPacking Wood board drum

24 fibers RQC - LCD

Profile/Outline12 fibers RQC - LCD

Page 23: FIBER OPTICS AND DATA COMMUNICATIONrosenberger.co.kr/data/(카탈로그) FTTA-Fiber to the... · 2016-12-31 · FIBER OPTICS AND DATA COMMUNICATION solution for wireless cellular

22

Specification

Trunk cable12 fibers 24 fibers

Side A (Top) 6*LC duplex 12*LC duplexSide B (Bottom) 6*LC duplex 12*LC duplexBreakout Cable Length 600mm, 700mm, 800mmCable Retention Force (Fiber Breakout) 200NCable Retention Force (Trunk Cable) 1000NCable Bending Radius Min (Installation) 10 times the cable diameterCable Bending Radius Min (Operation) 20 times the cable diameterOuter Diameter Nominal 6.2 ± 0.3mm 8.5 ± 0.5mmJacket Material LSZHFiber Type G657A, OM2, OM3Flammability IEC 60332-12011/65/EU(RoHS) CompliantTemperature Range -40°C ~ +85°CPacking Wood board drum

LC Trunk Solution

DescriptionTraditional trunk solution is a typical design using a LC connector terminated trunk cable and distribution box. The cable runs from the BBU up to a weatherproof distribution box at the tower top. The distribution box provides the interconnection point for fibers between the trunk cable and the jumpers leading to the RRHs.

Feature and Benefit• Up to 36 fibers • PRECONNECT® technologies• Loose tube cable with high tensile strength and crush resistance

Length±Tolerance

BA

BA

BA

BA

Length±Tolerance

BA

BA

BA

BA

Trunk Solution is the good choice for operators who lease space on tower cell sites. It reduces annual leasing costs by reducing the space utilized on the tower. Plug-and-Play connections minimize installation time and require no tools.

• Fiber jumpers available to support vendor-specific interfaces• Connects to FO patch panel at base station side• Reduced tower loading and leasing costs

Profile/Outline12 fibers LCD - LCD

24 fibers LCD - LCD

Page 24: FIBER OPTICS AND DATA COMMUNICATIONrosenberger.co.kr/data/(카탈로그) FTTA-Fiber to the... · 2016-12-31 · FIBER OPTICS AND DATA COMMUNICATION solution for wireless cellular

23

The New Generation of FTTA Cabling−Hybrid Solutions are effective in streamlining operations when replacing traditional base station equipment with RRH or upgrading a site to support RRH. A single hybrid cable provides multiple fiber and power transmission lines. This is advantageous as it consolidates space and provides room for growth for additional RRHs.

Rosenberger pre-terminated hybrid cable assemblies minimize the amount of cables running up the tower. A sin-gle hybrid cable provides several fibers and power conductors to support multiple RRHs. The flexible lightweight aluminum corrugated cable allows operators to ground the cabling system. To simplify installation, the Rosen-berger hybrid cable outer dimension follows standard feeder dimensions (1/2", 7/8"or 1-1/4") and enables the use of standard feeder clamps and grounding kits.

EasyLinkTM FTTA Hybrid Solution

Page 25: FIBER OPTICS AND DATA COMMUNICATIONrosenberger.co.kr/data/(카탈로그) FTTA-Fiber to the... · 2016-12-31 · FIBER OPTICS AND DATA COMMUNICATION solution for wireless cellular

24

EasyLinkTM RDC Hybrid Solution

DescriptionEasyLinkTM RDC (2-fiber Rosenberger Duplex Connector) terminated hybrid cable is an innovative solution to combine optical fibers and DC power lines in a single cable to simply the RRH deployments. The EasyLinkTM hybrid system is designed with slim dividers which split multi-fiber and DC cables into individual outdoor cables. The hybrid trunk cables are terminated with IP67-rated RDC connectors. Different types of jumpers are available

Feature and Benefit• Support up to 6 RRH• IP67 robust and compact divider • IP67 RDC and power connectors for water immersion and dust protection• Corrugated aluminum or copper tape armored design

to allow connection between the hybrid cable and any vendor-specific hardware interface.

EasyLinkTM Hybrid Solution is the best choice for operators who lease space on tower cell sites. It reduces annual leasing costs by reducing the space utilized on the tower. Plug-and-Play connections minimize installation time and require no tools.

• Plug-and-play installation• Reduced tower loading and leasing costs• Terminated with RDC on top breakout to connect with RRHs by matching RDC fiber jumpers• Easy adjustment of length of bottom breakout point

Page 26: FIBER OPTICS AND DATA COMMUNICATIONrosenberger.co.kr/data/(카탈로그) FTTA-Fiber to the... · 2016-12-31 · FIBER OPTICS AND DATA COMMUNICATION solution for wireless cellular

25

Length±Tolerance

AB

AB

AB

Length±Tolerance AB

AB

AB

AB

AB

AB

Length±Tolerance AB

AB

AB

AB

AB

AB

EasyLinkTM RDC Hybrid Trunk CableSpecification

Profile/Outline3X3 (Top side 3 power connectors and 3 RDC)

3X6 (Top side 3 power connectors and 6 RDC)

6x6 (Top side 6 power connectors and 6 RDC)

Page 27: FIBER OPTICS AND DATA COMMUNICATIONrosenberger.co.kr/data/(카탈로그) FTTA-Fiber to the... · 2016-12-31 · FIBER OPTICS AND DATA COMMUNICATION solution for wireless cellular

26

Hybrid Trunk

Number of RRH 3 RRH 6 RRHStructure 3X3, 3X6 6X6

Side A (Top)Fiber RDC (Rosenberger Duplex Connector)Power DC power Connector or open ended

Side B (Bottom)Fiber LC duplex Power open ended

DividerMaterial AluminumDiameter Min. Ф63mm Min. Ф80mmHeight 180mm 220mm

Breakout Cable Length (Top)*Fiber 600mm, 700mm, 800mmPower 500mm

Breakout Cable Length (Bottom)*

Fiber 1500mmPower 1500mm

Cable Retention Force (Divider)Fiber Breakout 200NPower Breakout 500NHybrid Trunk 1000N

Cable Bending Radius Min.Installation 10 times the cable diameterOperation 20 times the cable diameter

Temperature Range -40°C ~ +70°CPacking Wood board drum

Hybrid Cable

Number of RRH 3 RRH 6 RRHNumber of Copper Conductor 6 (3 pairs) 12 (6 pairs)Number of Fiber 6~12 12Conductor Size 4mm2 (12AWG), 6mm2 (10AWG), 10mm2 (8AWG)

Outer Diameter Nominal 27.5 ± 0.5mm (4mm2) 27.5 ± 0.5mm (4mm2)27.5 ± 0.5mm (6mm2) 27.5 ± 0.5mm (6mm2)27.5 ± 0.5mm (10mm2) 32± 0.8mm (10mm2)

Jacket Material FRPE, UV resistanceArmored Type Corrugated aluminum Copper tape

Fiber TypeSinglemode: G652D, G657A

Mulitmode: OM1, OM2, OM3, OM4Nominal Voltage Uo/U 600/1000VFlammability IEC 60332-1, IEC 60754-2, IEC 61034-22011/65/EU(RoHS) Compliant

Ordering Information

EasyLinkTM RDC Hybrid Series

Fiber type Number of RRH Number of fiberNumber of power

conductorPower

conductor(mm2)L98Y-C0001-XXX

G657A

3 6 6 4L98Y-C0002-XXX 3 6 6 6L98Y-C0003-XXX 3 6 6 10L98Y-C0025-XXX 3 12 6 4L98Y-C0026-XXX 3 12 6 6L98Y-C0027-XXX 3 12 6 10L98Y-C0103-XXX 6 12 12 4L98Y-C0104-XXX 6 12 12 6L98Y-C0105-XXX 6 12 12 10L98Y-C0004-XXX

OM2

3 6 6 4L98Y-C0005-XXX 3 6 6 6L98Y-C0006-XXX 3 6 6 10L98Y-C0028-XXX 3 12 6 4L98Y-C0029-XXX 3 12 6 6L98Y-C0030-XXX 3 12 6 10L98Y-C0106-XXX 6 12 12 4L98Y-C0107-XXX 6 12 12 6L98Y-C0108-XXX 6 12 12 10

*XXX represents length (mm). E. g. L98Y-C0001-20000 means trunk length 20m

Page 28: FIBER OPTICS AND DATA COMMUNICATIONrosenberger.co.kr/data/(카탈로그) FTTA-Fiber to the... · 2016-12-31 · FIBER OPTICS AND DATA COMMUNICATION solution for wireless cellular

27

EasyLinkTM RQC Hybrid Solution

Feature and Benefit • Support up to 9 RRH• IP67 robust and compact divider • IP67 RQC and power connectors for water immersion and dust protection• Corrugated aluminum or copper tape armored design• Plug-and-play installation• Reduced tower loading and leasing costs• Terminated with RQC on top breakout to connect with RRH by matching RQC fiber jumpers• Easy adjustment of length of bottom breakout point

Description EasyLinkTM RQC ( 4-fiber Rosenberger Quad Connector ) terminated hybrid cable is an innovative solution to combine optical fibers and DC power lines in a single cable to simply the RRH deployments. The EasyLinkTM hybrid system is designed with slim dividers which split multi-fiber and DC cables into individual outdoor cables. The hybrid trunk cables are terminated with IP67-rated RQC connectors. Different types of jumpers are available to allow

connection between the hybrid cable and any vendor-specific hardware interface.

EasyLinkTM Hybrid Solution is the best choice for operators who lease space on tower cell sites. It reduces annual leasing costs by reducing the space utilized on the tower. Plug-and-Play connections minimize installation time and require no tools.

Page 29: FIBER OPTICS AND DATA COMMUNICATIONrosenberger.co.kr/data/(카탈로그) FTTA-Fiber to the... · 2016-12-31 · FIBER OPTICS AND DATA COMMUNICATION solution for wireless cellular

28

Specification

Length±Tolerance

AB

AB

AB

AB

AB

AB

Length±Tolerance AB

AB

AB

AB

AB

AB

AB

AB

AB

AB

AB

AB

Length±Tolerance

EasyLinkTM RQC Hybrid Trunk Cable

Profile/Outline3X6 (Top side 3 power connectors and 3 RQC)

6X12 (Top side 6 power connectors and 6 RQC)

9X18 (Top side 9 power connectors and 9 RQC)

Page 30: FIBER OPTICS AND DATA COMMUNICATIONrosenberger.co.kr/data/(카탈로그) FTTA-Fiber to the... · 2016-12-31 · FIBER OPTICS AND DATA COMMUNICATION solution for wireless cellular

29

Hybrid Trunk

Number of RRH 3 RRH 6 RRH 9 RRHStructure 3X6 6X12 9X18

Side A (Top)Fiber RQC (Rosenberger Quad Connector)Power DC power Connector or open ended

Side B (Bottom)Fiber LC duplex MTPPower open ended

Divider Material AluminumDiameter Min. Ф63mm Min. Ф80mm Min. Ф80mmHeight 180mm 220mm 220mm

Breakout Cable Length (Top)*Fiber 600mm, 700mm, 800mmPower 500mm

Breakout Cable Length (Bottom)*Fiber 1500mmPower 1500mm

Cable Retention Force (Divider)Fiber Breakout 200NPower Breakout 500NHybrid Trunk 1000N

Cable Bending Radius Min.Installation 10 times the cable diameterOperation 20 times the cable diameter

Temperature Range -40°C ~ +70°CPacking Wood board drum

*customized lengths available

Hybrid Cable

Number of RRU 3 RRH 6 RRH 9 RRHNumber of Copper Conductor 6 (3 pairs) 12 (6 pairs) 18 (9 pairs)Number of Fiber 12 24 36Conductor Size 4mm2 (12AWG), 6mm2 (10AWG), 10mm2 (8AWG)

Outer Diameter Nominal 27.5 ± 0.5mm (4mm2) 27.5 ± 0.5mm (4mm2) 32± 0.8mm (4mm2)27.5 ± 0.5mm (6mm2) 27.5 ± 0.5mm (6mm2) 32± 0.8mm (6mm2)27.5 ± 0.5mm (10mm2) 32± 0.8mm (10mm2) 36± 0.8mm (10mm2)

Jacket Material FRPE, UV resistance Armored Type Corrugated aluminum Copper tape Copper tape

Fiber TypeSinglemode: G652D, G657A

Mulitmode: OM1, OM2, OM3, OM4Conductor Size 4mm2 (12AWG), 6mm2 (10AWG), 10mm2 (8AWG)Nominal Voltage Uo/U 600/1000VFlammability IEC 60332-1, IEC 60754-2, IEC 61034-22011/65/EU(RoHS) Compliant

Ordering Information

EasyLinkTM RQC Hybrid Series

Fiber type Number of RRH Number of fiberNumber of power

conductorPower

conductor(mm2)L98Y-C0109-XXX

G657A

3 12 6 4L98Y-C0110-XXX 3 12 6 6L98Y-C0111-XXX 3 12 6 10L98Y-C0115-XXX 6 24 12 4L98Y-C0116-XXX 6 24 12 6L98Y-C0117-XXX 6 24 12 10L98Y-C0121-XXX 9 36 36 4L98Y-C0122-XXX 9 36 36 6L98Y-C0123-XXX 9 36 36 10L98Y-C0112-XXX

OM2

3 12 6 4L98Y-C0113-XXX 3 12 6 6L98Y-C0114-XXX 3 12 6 10L98Y-C0118-XXX 6 24 12 4L98Y-C0119-XXX 6 24 12 6L98Y-C0120-XXX 6 24 12 10L98Y-C0124-XXX 9 36 36 4L98Y-C0125-XXX 9 36 36 6L98Y-C0126-XXX 9 36 36 10

*XXX represents length (mm). E.g. L98Y-C0109-20000 means trunk length 20m

Page 31: FIBER OPTICS AND DATA COMMUNICATIONrosenberger.co.kr/data/(카탈로그) FTTA-Fiber to the... · 2016-12-31 · FIBER OPTICS AND DATA COMMUNICATION solution for wireless cellular

30

EasyLinkTM RMCTM Hybrid Solution

DescriptionEasyLinkTM RMCTM (Rosenberger Multi-fiber Connector) terminated hybrid cable is an innovative solution to combine optical fibers and DC power lines in a single cable to simply the RRH deployments. The EasyLinkTM hybrid system is designed with slim dividers which split multi-fiber and DC cables into individual outdoor cables. RMCTM adopt standard MPO fiber interface with additional protection to work under harsh environments which particularly applicable for 6 RRH and 9 RRH solution. The hybrid trunk cables

Feature and Benefit • Support 6 RRH and 9 RRH• IP67 robust and compact divider • IP67 RMCTM and power connectors for water immersion and dust protection• 8 fibers and 12 fibers RMCTM as option• Corrugated aluminum or copper tape armored design • Plug-and-play installation• Reduced tower loading and leasing costs• Terminated with RMCTM in top breakout to connect with RRH by matching RMCTM fiber jumpers• Easy adjustment of length of bottom breakout point

are terminated with IP67-rated RMCTM connectors. Different types of jumpers are available to allow connection between the hybrid cable and any vendor-specific hardware interface.

EasyLinkTM Hybrid Solution is the best choice for operators who lease space on tower cell sites. It reduces annual leasing costs by reducing the space utilized on the tower. Plug-and-Play connections minimize installation time and require no tools.

Page 32: FIBER OPTICS AND DATA COMMUNICATIONrosenberger.co.kr/data/(카탈로그) FTTA-Fiber to the... · 2016-12-31 · FIBER OPTICS AND DATA COMMUNICATION solution for wireless cellular

31

Length±Tolerance AB

AB

AB

AB

AB

AB

AB

AB

AB

AB

AB

AB

Length±Tolerance

EasyLinkTM RMCTM Hybrid Trunk Cable

SpecificationProfile/Outline6X12 ( Top side 6 power connectors and 3 RMCTM )

9X18 ( Top side 9 power connectors and 3 RMCTM )

Page 33: FIBER OPTICS AND DATA COMMUNICATIONrosenberger.co.kr/data/(카탈로그) FTTA-Fiber to the... · 2016-12-31 · FIBER OPTICS AND DATA COMMUNICATION solution for wireless cellular

32

Hybrid Trunk

Number of RRU 6 RRH 9 RRHStructure 6X12 9X18

Side A (Top)Fiber RMCTM 8 fibers RMCTM 12 fibersPower DC power Connector or open ended

Side B (Bottom)Fiber LCD MTP 12 fibersPower Open ended

DividerMaterial AluminiumDiameter Min. Ф63mm Min. Ф80mmHeight 180mm 220mm

Breakout Cable Length (Top)*Fiber 600mm, 700mm, 800mmPower 500mm

Breakout Cable Length (Bottom)*

Fiber 1500mmPower 1500mm

Cable Retention Force (Divider)Fiber Breakout 200NPower Breakout 500NHybrid Trunk 1000N

Cable Bending Radius Min.Installation 10 times the cable diameterOperation 20 times the cable diameter

Temperature Range -40°C ~ +70°CPacking Wood board drum

*customized lengths available

Hybrid Cable

Number of RRU 6 RRH 9 RRHNumber of Copper Conductor 6 (3 pairs) 18 ( 9 pairs)Number of Fiber 24 36Conductor Size 4mm2 (12AWG), 6mm2 (10AWG), 10mm2 (8AWG)

Outer Diameter Nominal 27.5 ± 0.5mm (4mm2) 32± 0.8mm ( 4mm2)27.5 ± 0.5mm (6mm2) 32± 0.8mm ( 6mm2)32± 0.8mm (10mm2) 36± 0.8mm (10mm2)

Jacket Material FRPE, UV resistance Armored Type Copper tape Copper tape

Fiber TypeSinglemode: G652D, G657A

Mulitmode: OM1, OM2, OM3, OM4Nominal Voltage Uo/U 600/1000VFlammability IEC 60332-1, IEC 60754-2, IEC 61034-22011/65/EU(RoHS) Compliant

Ordering Information

RMCTM Hybrid Series Fiber type Number of RRH Number of fiber Number of power conductor Power conductor(mm2)

L98Y-C0127-XXX

G657A

6 24 12 4

L98Y-C0128-XXX 6 24 12 6

L98Y-C0129-XXX 6 24 12 10

L98Y-C0133-XXX 9 36 36 4

L98Y-C0134-XXX 9 36 36 6

L98Y-C0135-XXX 9 36 36 10

L98Y-C0130-XXX

OM2

6 24 12 4

L98Y-C0131-XXX 6 24 12 6

L98Y-C0132-XXX 6 24 12 10

L98Y-C0136-XXX 9 36 36 4

L98Y-C0137-XXX 9 36 36 6

L98Y-C0138-XXX 9 36 36 10

*XXX represents length (mm). E.g. L98Y-C0127-20000 means trunk length 20m

Page 34: FIBER OPTICS AND DATA COMMUNICATIONrosenberger.co.kr/data/(카탈로그) FTTA-Fiber to the... · 2016-12-31 · FIBER OPTICS AND DATA COMMUNICATION solution for wireless cellular

33

EasyLinkTM LC Hybrid Solution

Traditional Hybrid Solution is a typical design using a LC connector terminated hybrid cable and distribution box. The cable runs from the BBU up to a weatherproof distribution box at the tower top. The distribution box provides the interconnection point for power and fiber between the hybrid cable and the jumpers leading to the RRH. The Distribution box can include over-voltage protection

(OVP). A secondary distribution box at the bottom is optional.

Towers containing multiple sectors can be supported by multiple LC terminated hybrid trunks. For example, 12 RRHs can be supported with only three LC terminated trunk cables running up to the tower.

Feature and Benefit• Support up to 6 RRH per distribution box• Support up to 4 RRH per hybrid cable• Hybrid tail jumpers instead of individual fiber and power jumpers to support vendor- specific interface• Flexibility to replace or upgrade RRH by changing hybrid tail jumpers• IP67 Hybrid distribution box for fiber and power• Easily grounded within the distribution box• Easy adjustment of length of breakout point in hybrid cable• Connects to FO patch panel at base station side

Description

Page 35: FIBER OPTICS AND DATA COMMUNICATIONrosenberger.co.kr/data/(카탈로그) FTTA-Fiber to the... · 2016-12-31 · FIBER OPTICS AND DATA COMMUNICATION solution for wireless cellular

34

EasyLinkTM LC Hybrid Trunk Cable

Specification

Hybrid Trunk

Side A (Top)Fiber LC duplex Power Open ended

Side B (Bottom)Fiber LC duplex Power Open ended

Breakout Cable Length (Top)*Fiber 600mm, 700mm, 800mmPower 500mm

Breakout Cable Length (Bottom)*Fiber 4mPower 4m

Cable Bending Radius Min.Installation 10 times the cable diameterOperation 20 times the cable diameter

Temperature Range -40°C ~ +70°CPacking Wood board drum

*customized lengths available

Trunk Cable

Number of RRH 4 RRHNumber of Copper Conductor 8 (4 pairs)Number of Fiber Up to 16Conductor Size 4mm2 (12AWG), 6mm2 (10AWG), 10mm2 (8AWG)

Outer Diameter Nominal27.5 ± 0.5mm (4mm2)27.5 ± 0.5mm (6mm2)27.5 ± 0.5mm (10mm2)

Jacket Material FRPE, UV resistance Armored Type Corrugated aluminum

Fiber TypeSinglemode: G652D, G657AMulitmode: OM1, OM2, OM3, OM4

Nominal Voltage Uo/U 600/1000VFlammability IEC 60332-1, IEC 60754-2, IEC 61034-22011/65/EU(RoHS) Compliant

Ordering Information

LC Hybrid Series Fiber type Number of RRH Number of fiberNumber of

power conductorPower

conductor (mm2)L98Y-C0081-XXX

G657A4 12 6 4

L98Y-C0082-XXX 4 12 6 6L98Y-C0083-XXX 4 12 6 10L98Y-C0084-XXX

OM24 12 6 4

L98Y-C0085-XXX 4 12 6 6L98Y-C0086-XXX 4 12 6 10

*XXX represents length (mm). E.g. L98Y-C0127-20000 means trunk length 20m

Page 36: FIBER OPTICS AND DATA COMMUNICATIONrosenberger.co.kr/data/(카탈로그) FTTA-Fiber to the... · 2016-12-31 · FIBER OPTICS AND DATA COMMUNICATION solution for wireless cellular

35

RRH JumperRosenberger provides standard and customized RRH jumpers for connection between Rosenberger FTTA trunk cable assemblies or Rosenberger FTTA hybrid cable assemblies and remote radio heads (RRHs). RRH jumper provides installation and upgrade flexibility for different cellular site scenarios. Fiber optic jumper, power jumper as well as hybrid jumper are available from Rosenberger with 100% factory assembled and tested, and are com-patible with all types of system vendor equipment interfaces. Particularly the Rosenberger RDC, RQC and RMCTM terminated fiber jumpers provide IP67-rated direct connection without extra distribution box required, which sig-nificantly ease the installation and reduce labor costs.

Page 37: FIBER OPTICS AND DATA COMMUNICATIONrosenberger.co.kr/data/(카탈로그) FTTA-Fiber to the... · 2016-12-31 · FIBER OPTICS AND DATA COMMUNICATION solution for wireless cellular

36

A B

AB

DescriptionThe RDC (2-fiber Rosenberger Duplex Connector) fiber jumper can directly connect RRHs and EasyLinkTM hybrid trunk cable assembly or FTTA trunk cable assembly. Terminated with

RDC Fiber Jumper

Feature and Benefit• Plug-and-play installation and convenient maintenance• IP67 outdoor waterproof 2- fiber connector• Flexibility to replace or upgrade RRH by changing RDC jumpers

Specification

RDC connector, these jumpers provide convenient and quick interconnection between the trunk cable and RRH or other equipment.

Insertion Loss Max.RDC 0.5dBLC 0.3dB

Return Loss Min. (Singlemode)RDC 50dBLC 50dB

Cable Diameter* 4.8mm

Fiber TypeSinglemode: G652D, G657AMulitmode: OM1, OM2, OM3, OM4

Cable Bending Radius Min.Installation 50mmOperation 30mm

Cable Tensile Strength Max.Installation 450NOperation 300N

Cable Crush Resistance 3KN/100mm

Temperature Range Operation -40°C ~ +80°CStorage -40°C ~ +80°CInstallation -20°C ~ +65°C

2011/65/EU (RoHS) Compliant* Other cable size options are available upon request.

Ordering Information

RDC Jumper Series Fiber Type Number of Fiber Top Connector Bottom ConnectorL98B-893-XXX

G657A2 LCD with RFE RDC Ericsson

L98B-894-XXX 2 LCD RDC HuaweiL98B-895-XXX 2 LCD with IP seal RDC NokiaL98C-853-XXX

OM22 LCD with RFE RDC Ericsson

L98C-854-XXX 2 LCD RDC HuaweiL98C-855-XXX 2 LCD with IP seal RDC Nokia

*XXX represent length (mm) from end to end. E.g. L98B-893-XXX means jumper length 5m.

For Nokia RRH For Ericsson RRH For Huawei RRH

Profile/OutlineSide A Side B Side A Side B Side A Side B

Page 38: FIBER OPTICS AND DATA COMMUNICATIONrosenberger.co.kr/data/(카탈로그) FTTA-Fiber to the... · 2016-12-31 · FIBER OPTICS AND DATA COMMUNICATION solution for wireless cellular

37

Insertion Loss Max.RQC 0.5dBLC 0.3dB

Return Loss Min. (Singlemode)RQC 50dBLC 50dB

Fiber TypeSinglemode: G652D, G657AMulitmode: OM1, OM2, OM3, OM4

Cable Diameter* 4.8mm

Cable ending Radius Min.Installation 50mmOperation 30mm

Cable Tensile Strength Max.Installation 450NOperation 300N

Cable Crush Resistance 1KN/100mm

Temperature Range Operation -40°C ~ +80°CStorage -40°C ~ +80°CInstallation -20°C ~ +65°C

2002/95/EC (RoHS) Compliant* Other cable size options are available upon request.

Ordering Information:RQC Jumper Series Fiber Type Number Of Fiber Top Connector Bottom ConnectorL98B-896-XXX

G657A4 LCD with RFE RQC Ericsson

L98B-897-XXX 4 LCD RQC HuaweiL98B-898-XXX 4 LCD with IP seal RQC NokiaL98C-856-XXX

OM24 LCD with RFE RQC Ericsson

L98C-857-XXX 4 LCD RQC HuaweiL98C-858-XXX 4 LCD with IP seal RQC Nokia

*XXX represents length (mm) from end to end. E.g. L98B-896-XXX means jumper length 5m.

DescriptionThe RQC (4-fiber Rosenberger Quad Connector) fiber jumper can divectly connect RRHs and EasyLinkTM hybrid trunk cable assembly or FTTA trunk cable assembly. Terminated with

Feature and Benefit• Plug-and-play installation and convenient maintenance• High density 4-fiber Jumper• IP67 outdoor waterproof fiber 4-fiber connector

• Flexibility to replace or upgrade RRHs by changing RQC jumpers

RQC Fiber Jumper

A B

A B

AB

AB

Specification

For Nokia RRH For Ericsson RRH For Huawei RRH

Profile/Outline

RQC connector, these jumpers provide convenient and quick interconnections between the trunk cable and RRH or other equipment.

Side A Side A Side A

Side B Side B Side B

Page 39: FIBER OPTICS AND DATA COMMUNICATIONrosenberger.co.kr/data/(카탈로그) FTTA-Fiber to the... · 2016-12-31 · FIBER OPTICS AND DATA COMMUNICATION solution for wireless cellular

38

Specification

Insertion Loss Max.RMCTM 0.5dBLC 0.3dB

Return Loss Min. (Singlemode)RMCTM 50dBLC 50dB

Fiber TypeG657AOM2

Cable Diameter* 6.0mm

Cable ending Radius Min.Installation 50mmOperation 30mm

Cable Tensile Strength Max.Installation 450NOperation 300N

Cable Crush Resistance 3KN/100mm

Temperature Range Operation -40°C ~ +80°CStorage -40°C ~ +80°CInstallation -20°C ~ +65°C

2011/65/EU (RoHS) Compliant* Other cable size options are available upon request.

Ordering InformationRMCTM Jumper Series Fiber Type Number Of Fiber Top connector Bottom ConnectorL98B-899-XXX

G657A8 LCD with RFE RMCTM Ericsson

L98B-900-XXX 8 LCD RMCTM HuaweiL98B-901-XXX 8 LCD with IP seal RMCTM NokiaL98C-859-XXX

OM28 LCD with RFE RMCTM Ericsson

L98C-860-XXX 8 LCD RMCTM HuaweiL98C-861-XXX 8 LCD with IP seal RMCTM NokiaL98B-902-XXX

G657A12 LCD with RFE RMCTM Ericsson

L98B-903-XXX 12 LCD RMCTM HuaweiL98B-904-XXX 12 LCD with IP seal RMCTM NokiaL98C-862-XXX

OM212 LCD with RFE RMCTM Ericsson

L98C-863-XXX 12 LCD RMCTM HuaweiL98C-864-XXX 12 LCD with IP seal RMCTM Nokia

*XXX represents length (mm) from end to end. E.g. L98B-896-XXX means jumper length 5m.

Feature and Benefit• Plug-and-play installation and convenient maintenance• High density up to 12/24 fiber• IP67 outdoor waterproof fiber multi-fiber connector• Flexibility to replace or upgrade RRHs by changing RMCTM jumpers

RMCTM Fiber Jumper

DescriptionThe RMCTM (Rosenberger Multi-fiber Connector) fiber jumper can directly connect RRHs and EasyLinkTM hybrid trunk cable assembly or FTTA trunk cable assembly. Terminated with

RMCTM connector, these jumpers provide convenient and quick interconnections between the trunk cable and RRH or other equipment.

Page 40: FIBER OPTICS AND DATA COMMUNICATIONrosenberger.co.kr/data/(카탈로그) FTTA-Fiber to the... · 2016-12-31 · FIBER OPTICS AND DATA COMMUNICATION solution for wireless cellular

39

DescriptionThe hybrid jumper can be used to connect RRH and EasyLinkTM

hybrid cable assembly with a hybrid distribution box on top of tower. One end of jumper is usually terminated with LC connector or other equipment vendor-specific interface, and the other

end is terminated with standard LC connector. Power line ends are opened but possibly be terminated with customer-specific connectors upon request.

Feature and Benefit• Corrugated hybrid cable• IP67 waterproof protection at RRH side• Standard or customized length • Flexibility to replace or upgrade RRH by changing hybrid jumpers

SpecificationProfile/Outline

Hybrid Jumper

AB

AB

A B

A B

AB

AB

AB

AB

For Nokia RRH For Ericsson RRH For Huawei RRH

Specification

Side A(Top)Fiber LC duplex or vendor-specific interfaces

Power Open ended

Side B(Bottom)Fiber LC duplex

Power Open ended

Breakout Cable Length*(Top)Fiber 0.75m

Power 0.75m

Breakout Cable Length*(Bottom)Fiber 0.5m

Power 0.5m

Insertion Loss Max. LC 0.3dB

Return Loss Min. (Singlemode) LC 50dB

Cable Bending Radius Min.Installation 50mm

Operation 30mm

Cable Tensile Strength Max.Installation 450N

Operation 300N

Cable Crush Resistance 1KN/100mm

Side A Side B Side A Side B Side A Side B

Page 41: FIBER OPTICS AND DATA COMMUNICATIONrosenberger.co.kr/data/(카탈로그) FTTA-Fiber to the... · 2016-12-31 · FIBER OPTICS AND DATA COMMUNICATION solution for wireless cellular

40

Temperature Range

Operation -40°C ~ +80°C

Storage -40°C ~ +80°C

Installation -20°C ~ +65°C

2011/65/EU(RoHS) Compliant

* Other cable length options are available upon request.

Hybrid Cable

Number of RRH 1 RRH

Number of Fiber 2 to 4

Number of Conductor 2 (1 pair)

Outer Diameter Nominal 15.8 ± 0.5mm (1/2" cross-section)

Conductor Size 4mm2 (12AWG), 6mm2 (10AWG)

Jacket Material LSZH, UV resistance

Armored Type Corrugated aluminum

Fiber TypeSinglemode: G652D, G657A

Multimode: OM1, OM2, OM3, OM4

Nominal Voltage Uo/U 600/1000V

Flammability IEC 60332-1

2011/65/EU(RoHS) Compliant

Ordering Information

Hybrid Jumper Series Fiber Type Number Of Fiber Conductor Top Connector Bottom Connector

L98Y-718-XXX

G657A

4 6mm2 LCD with RFE LCD Ericsson

L98Y-717-XXX 4 6mm2 LCD LCD Huawei

L98Y-716-XXX 4 6mm2 LCD with IP seal LCD Nokia

L98Y-727-XXX

OM2

4 6mm2 LCD with RFE LCD Ericsson

L98Y-726-XXX 4 6mm2 LCD LCD Huawei

L98Y-725-XXX 4 6mm2 LCD with IP seal LCD Nokia

*XXX represents length (mm) from end to end. E.g. L98Y-718-XXX means jumper length 5m.

Page 42: FIBER OPTICS AND DATA COMMUNICATIONrosenberger.co.kr/data/(카탈로그) FTTA-Fiber to the... · 2016-12-31 · FIBER OPTICS AND DATA COMMUNICATION solution for wireless cellular

41

Distribution BoxRosenberger ruggedized distribution box made of high-grade engineering plastic material provides the intercon-nection point between RRH jumpers and main FTTA trunk or hybrid cable assemblies. The distribution and inter-connection of whatever main FTTA hybrid cable, fiber trunk cable and DC power trunk cable can be implemented seamlessly and flexibly over cost-effective Rosenberger distribution boxes. It supports up to 6/12 RRHs which makes the network cabling system installation, maintenance, upgrade and expansion possible and supports multi-vendor installations. Standard and customized distribution boxes are available.

Page 43: FIBER OPTICS AND DATA COMMUNICATIONrosenberger.co.kr/data/(카탈로그) FTTA-Fiber to the... · 2016-12-31 · FIBER OPTICS AND DATA COMMUNICATION solution for wireless cellular

42

Fiber Distribution Box

Description Rosenberger fiber distribution box can be used at tower top or at bottom for fiber management, and it provides cost-effective and flexible solution for installing multiple RRHs.

Specification

Number of RRH Up to 12 RRH

Dimension (L x W x H) 300mm x 200mm x 132mm

Fiber Cores Up to 24 fibers

Fiber Type Both singlemode and multimode

Mounting Pole, wall

Material Polycarbonate

Cable Gland M25x1.5mm (Φ3-Φ7, mm) Up to 4

Input Cable Diameter FO cable (Φ3-Φ7mm)

output Cable Diameter FO cable (Φ3-Φ7mm)

Sealing of Jumpers Multihole cable glands

IP Rating IP66

Operation Temperature -40°C ~ +85°C

Earthing Grounding cable

2011/65/EU (RoHS) Compliant

Feature and Benefit • Support up to 12 RRH• LC adapters pre-assembled• IP66 waterproof protection to fiber connections• One main entry for FTTA trunk • Up to three fiber jumper entries• Hinged cover• UV resistant• Mounting brackets and cable glands included

Page 44: FIBER OPTICS AND DATA COMMUNICATIONrosenberger.co.kr/data/(카탈로그) FTTA-Fiber to the... · 2016-12-31 · FIBER OPTICS AND DATA COMMUNICATION solution for wireless cellular

43

Description Rosenberger power distribution box can be used at tower top or at bottom for power management, and it provides cost-effective and flexible solution for installing multiple RRHs. The box can be supplied with overvoltage protective (OVP) device.

Power Distribution Box

Specification

Number of RRH Up to 3 RRH and 4 RRH Up to 6 RRH

Dimension (L x W x H) 200mm x 200mm x 132mm 300mm x 200mm x 132mm

Mounting Pole, wall

Material Polycarbonate

Cable Gland M40x1.5mm (Φ19-Φ28mm)1

6x6mm2, 6x10mm2, 2x16mm2, 2x25mm2

Cable Gland M20x1.5mm (Φ8-Φ13mm)3 6

2x4mm2, 2x6mm2

Sealing of Jumpers Multihole cable glands

IP Rating IP66

Operation Temperature -40°C ~ +85°C

2011/65/EU (RoHS) Compliant

Feature and Benefit• Support up to 6 RRH• Power terminal block pre-assembled• IP66 waterproof protection to power connections• One main entry for power trunk• Up to three power jumper entries• Hinged cover• UV resistant• Mounting brackets and cable glands included• Circuit breaker options

Page 45: FIBER OPTICS AND DATA COMMUNICATIONrosenberger.co.kr/data/(카탈로그) FTTA-Fiber to the... · 2016-12-31 · FIBER OPTICS AND DATA COMMUNICATION solution for wireless cellular

44

Hybrid Distribution Box

DescriptionRosenberger Hybrid distribution box can be used at tower top or at bottom for both fiber and power management, and it provides cost-effective and flexible solution for installing multiple RRHs. The box is with patented design by Rosenberger and is most suitable to be installed with Rosenberger EasyLinkTM hybrid cables.

Specification

Number of RRH Up to 4 RRH Up to 6 RRH

Dimension (L x W x H) 300mm x 300mm x 130mm 300mm x 400mm x 130mm

DC Power up to 4 pairs up to 6 pairs

Fiber Cores up to 16 fibers up to 24 fibers

Fiber Type Both singlemode and multimode

Mounting Pole, wall

Material Polycarbonate

Hybrid Trunk Cable 1 (7/8" cross-section) 2 (7/8" cross-section)

Hybrid Jumper 4 (1/2" cross-section) 6 (1/2" cross-section)

Sealing of Jumpers Cable Gland M25x1.5mm(Φ11-Φ17mm)

IP Rating IP66

Operation Temperature -40°C ~ +85°C

Earthing Grounding cable

2011/65/EU (RoHS) Compliant

Feature and Benefit • Support up to 6 RRH• LC adapters pre-assembled• Power terminal block pre-assembled• IP66 waterproof protection to fiber and power connections• One main entry for hybrid cable• Up to six hybrid jumper entries

• Hybrid cable and jumper grounded within box• Hinged cover• UV resistant• Mounting brackets and cable glands included• Circuit breaker options

Page 46: FIBER OPTICS AND DATA COMMUNICATIONrosenberger.co.kr/data/(카탈로그) FTTA-Fiber to the... · 2016-12-31 · FIBER OPTICS AND DATA COMMUNICATION solution for wireless cellular

45

Installation AccessoryRosenberger designs, manufactures and supplies the complete series of installation accessories for wireless cel-lular site feeder system including cable clamp, hoisting grip, cable tie, grounding kit, grounding bar, hose clamp, weatherproof kit, cable entry kit, circuit breaker and etc. Particularly the standard sized cable clamps and ground-ing kits can be used as necessary for installing Rosenberger FTTA fiber cables and EasyLinkTM hybrid cables.

Page 47: FIBER OPTICS AND DATA COMMUNICATIONrosenberger.co.kr/data/(카탈로그) FTTA-Fiber to the... · 2016-12-31 · FIBER OPTICS AND DATA COMMUNICATION solution for wireless cellular

46

DescriptionRosenberger cable clamps are universal parts which work with different feeder cables and FTTA RRH installation solutions. They are easy to install and allow for an upgrade or exchange

of cables. The selected stainless steel and UV-resistant material guarantees the long-term site material installation quality which has been proven by many customers’ field application.

Ordering Information

Part Number Description Suitable Cable Size

SLCC111-C03 Single Hole Cable Clamp, 1-way 1/2"

SLCC121-C03 Single Hole Cable Clamp, 2-way 1/2"

SLCC131-C03 Single Hole Cable Clamp, 3-way 1/2"

SLCC111-C05 Single Hole Cable Clamp, 1-way 7/8"

SLCC121-C05 Single Hole Cable Clamp, 2-way 7/8"

SLCC131-C05 Single Hole Cable Clamp, 3-way 7/8"

SLCC111-C06 Single Hole Cable Clamp, 1-way 1-1/4"

SLCC121-C06 Single Hole Cable Clamp, 2-way 1-1/4"

SLCC131-C06 Single Hole Cable Clamp, 3-way 1-1/4"

SLCC211-C03 Double Hole Cable Clamp, 1-way 1/2"

SLCC221-C03 Double Hole Cable Clamp, 2-way 1/2"

SLCC231-C03 Double Hole Cable Clamp, 3-way 1/2"

SLCC211-C05 Double Hole Cable Clamp, 1-way 7/8"

SLCC221-C05 Double Hole Cable Clamp, 2-way 7/8"

SLCC231-C05 Double Hole Cable Clamp, 3-way 7/8"

SLCC211-C06 Double Hole Cable Clamp, 1-way 1-1/4"

SLCC221-C06 Double Hole Cable Clamp, 2-way 1-1/4"

SLCC231-C06 Double Hole Cable Clamp, 3-way 1-1/4"

SLCC211-ZF1 Two-Size Cable Clamp, 1-wayFiber: Φ4.5 - Φ7mm ( Grey ) Power: Φ9 - Φ13mm ( Black )

SLCC241-ZF1 Two-Size Cable Clamp, 2-way

SLCC261-ZF1 Two-Size Cable Clamp, 3-way

SLCC111-36.5 Hybrid Cable Clamp, 1-way D36-37mm

SLCC121-36.5 Hybrid Cable Clamp, 2-way D36-37mm

SLCC131-36.5 Hybrid Cable Clamp, 3-way D36-37mm

SLCC115-32.5 Hybrid Cable Clamp, 1-way D32-33mm

Cable Clamp

Page 48: FIBER OPTICS AND DATA COMMUNICATIONrosenberger.co.kr/data/(카탈로그) FTTA-Fiber to the... · 2016-12-31 · FIBER OPTICS AND DATA COMMUNICATION solution for wireless cellular

47

Ordering Information

Part Number Description Suitable Cable Size

SLGK001-C03-xxx1) Grounding Kit with quick lock shielding 1/2"

SLGK001-C05-xxx1) Grounding Kit with quick lock shielding 7/8"

SLGK001-C06-xxx1) Grounding Kit with quick lock shielding 1-1/4"

SLGK004-C03-xxx1) Grounding Kit with tread lock shielding 1/2"

SLGK004-C05-xxx1) Grounding Kit with tread lock shielding 7/8"

SLGK004-C06-xxx1) Grounding Kit with tread lock shielding 1-1/4"

SLGKT003D-xxx2) Grounding kits for different series cable All sizes

Note 1), XXX is the length of grounding wire which in cm. E.g. P/N: SLGK001-C03-150 The length of grounding wire is 150cm.

DescriptionConsidering the expensive telecommunication equipments, it is very important to set up the grounding well to prevent the equipment from the lighting strikes. The grounding kits are the key components which will be installed in field system every 40-60m. Rosenberger grounding kits provide best diversion function and the selected material guarantees the long-term site material installation quality which has been proven by many customers’ field application.

Grounding Kits

Hoisting Grips Description

Hoisting Grips are available for a wide range of coaxial and hybrid

cable sizes, made up of mesh grip with single eye support and it allows for quick and efficient installation. Different types are available to be fit for most of different feeder cables and FTTA RRH installation solutions.

Ordering Information

Part Number Description Suitable Cable Size

SLHG001-C03 Pre-placed Hoisting grips 1/2"

SLHG001-C05 Pre-placed Hoisting grips 7/8"

SLHG001-C06 Pre-placed Hoisting grips 1-1/4"

SLHG003-C03 Hoisting grips with open edge 1/2"

SLHG003-C05 Hoisting grips with open edge 7/8"

SLHG003-C06 Hoisting grips with open edge 1-1/4"

Page 49: FIBER OPTICS AND DATA COMMUNICATIONrosenberger.co.kr/data/(카탈로그) FTTA-Fiber to the... · 2016-12-31 · FIBER OPTICS AND DATA COMMUNICATION solution for wireless cellular

48

Fiber Optic Interconnect ProductsRosenberger provides high quality fiber optic inter-connect products for supporting the communication equip-ment cross connection in switching and transmission rooms. All fiber optic patchcord and pigtail are designed, manufactured and tested to international standards IEC and Telecordia by long-term reliability performance guar-anteed. Rosenberger fiber optic patch panel system is designed for EIA 19” rack and compatible with all common factory assembled or site-installed fiber cables, and most suitable to work with pre-assembled Rosenberger FTTA cables. Rack-mountable Rosenberger VelaTM fiber patch panel can reach up to 96-fibers LC connectivity in one height unit (1HU) dimension by also supporting MTP/MPO interface.

Page 50: FIBER OPTICS AND DATA COMMUNICATIONrosenberger.co.kr/data/(카탈로그) FTTA-Fiber to the... · 2016-12-31 · FIBER OPTICS AND DATA COMMUNICATION solution for wireless cellular

49

SpecificationFiber

Fiber TypeStandard

IEC 60793 ISO 11801 ITU-T G65X Series

Multimode 62.5/125μm A1b OM1 N/A

Multimode 50/125μm A1a

OM2

G651OM3

OM4

Singlemode 9/125μm

B1.1 OS1 G652A/G652B

B1.2 N/A G654

B1.3 OS2 G652C/G652D

B2 N/A G653

B4 N/A G655

B5 N/A G656

B6 N/A G657A/G657B

Patchcord & Pigtail

Feature and Benefit• Fiber types: Singlemode 9/125μm (G652D, G657A/B), Multimode

50/125μm (OM2/OM3/OM4), Multimode 62.5/125μm (OM1)• Outer sheath made of riser, plenum or LSZH rated material• Available with simplex cable, duplex cable, mini-zipcord cable,

ribbon cable, and other types of cables on request• UL or Anatel approved cable available• Available with ST, SC, FC, LC, MU, MTP/MPO, E2000, and other

DescriptionAll industry standard fiber optic connectivity together with customized connectors are available from Rosenberger for terminating to all kinds of patchcord and/or pigtail at different

lengths. With great in-house manufacturing of fiber optic connector, cable and cable assembly, it provides Rosenberger the advantages of flexibility, superior quality and quick turn-around.

Application• Channel to channel connection of fiber optic lines installed within

distribution panels or equipment• Connection of peripheral devices with a fiber optic interface

• On-site splicing with bulk cable• Other scenarios where fiber connection is required

types of connector on request• 100% performance tested• Providing test report for 3D geometric characteristics of

connector end-face as required• Separately packed in plastic bag, including serial number and

attenuation data, and other types of packing on request

Page 51: FIBER OPTICS AND DATA COMMUNICATIONrosenberger.co.kr/data/(카탈로그) FTTA-Fiber to the... · 2016-12-31 · FIBER OPTICS AND DATA COMMUNICATION solution for wireless cellular

50

Optical Cable

Cable Construction Simplex Cable Duplex Cable Mini-Cable Multi-FiberOptical Cable

Fiber QTY 1 2 1 2 4/6/8/12 24

Diameter (mm) 2.0 3.0 2.0*4.1 2.9*5.8 1.6 1.6*3.3 3.0 3.6

Max. Tensile (N) 120 150 150 200 80 120 100 120

Max. Crush (N/10cm) 500 500 500 500 300 300 100 100

Min. Bending Radius (mm) 20 30 20 30 16 16 30 36

Temperature Range -25℃ to +70℃ -20℃ to +70℃

Connector

Connector Type Interfaces StandardConnector Optical Interface Standard

PC 8 degrees angled-PC (APC)

SC IEC 61754-4 Radius 7~25mm Radius 5~12mm

FC IEC 61754-13 Fiber Height -100~+50nm Fiber Height -100~+50nm

ST IEC 61754-2 Apex Offset ≤ 50 μm Apex Offset ≤ 50 μm

LC IEC 61754-20 Angle N/A Angle 8± 0.3°

MU IEC 61754-6 Other parameter according to IEC 61755-3-1

Other parameter according to IEC 61755-3-2E2000 IEC 61754-15

MTP IEC 61754-7 IEC 61755-3-32

Cable Assembly

Connector Type LC, SC, FC, ST, MU E2000 MPO/MTP StandardFiber Type SM MM SM MM SM MM See table1

Insertion Loss (IL, dB) Max 0.3 Max 0.3 ≤0.6 ≤0.5 IEC 61300-3-4 Method B

Return Loss (RL, dB)For UPC 50 35 55 40 / 20 IEC 61300-3-6

Method 1Return Loss (RL, dB)For 8°APC 60 / 70 / 60 / IEC 61300-3-6

Method 1 Max. Tensile (N)(Cable & Connector) 70 100 100 80 80 IEC 61300-2-4

Temperature Range -25℃ to +70℃ -20℃ to +60℃ IEC 61300-2-22

Ordering Information

Fiber OpticalCable Assembly

HECM - -Length(<1KM) XXXXXX = XXXXXX mm(≥1KM) XXX KM =XXX KM

Type Of Fiber1=OM1 62.5/125um2=OM2 50/125um3=OM3 50/125um7=G657A19=G652DA=G657A2

Cable TypeO=nakedH=LSZHG=PVC(OFNG)R=PVC(OFNR)P=PVC(OFNP)

Cores1=1F2=2F

Shape of CableY=rollP=drop cableZ=8 figure

Cable Dia.2=2.0mm3=3.0mm6=1.6mm8=1.8mm9=0.9mm

Cable color (If to be defined)BL=BlueOR=OrangeGR=GreenBR=BrownSL=SlateWH=WhiteRD=RedBK=BlackYL=YellowVT=VioletRS=RoseRS=RoseAQ=Aqua

Connector B0=empty1=ST2=SC3=FC4=LC5=LCD9=E2000C=MUD=SCD

Connector A1=ST2=SC3=FC4=LC5=LCD9=E2000C=MUD=SCD

Polishing Level (If to be defined)A=APC(pigtail)B=APC-APCC=PC-APCD=APC-PCE=PC(pigtail)

Page 52: FIBER OPTICS AND DATA COMMUNICATIONrosenberger.co.kr/data/(카탈로그) FTTA-Fiber to the... · 2016-12-31 · FIBER OPTICS AND DATA COMMUNICATION solution for wireless cellular

51

Ordering Information

10 -

Digit 21: SC/SC simplex SM4: SC/SC simplex MM5: SC/SC Duplex SM6: SC/SC Duplex MMC: LC/LC Duplex SMD: LC/LC Duplex MME: FC/FC simplexG: SC/APC simplexK: E2000/E2000

Digit 45: Black

Digit 11: 1 HU Distribution Panel 2: 1 HU Splice Panel3: 1 HU Sliding Distribution Panel4: 1 HU Sliding Splice Panel

Digit 32: 12 Fibers3: 24 Fibers4: 48 Fibers6: 8 Fibers7: 32 Fibers8: 4 FibersC: 6 FibersD: 36 Fibers

Digit 51A: Steel material

DescriptionRosenberger HDCS® distribution & splice fiber optic patch panel insures good management for the four critical elements of fiber optic cable: bend radius protection, cable routing path, cable access and physical protection. Those four aspects directly affect the reliability, functionality and the operational cost of the network.

SpecificationSliding-type:483 x 300 x 1HU (mm) and 483x 300 x 2HU (mm)

Delivery Form• Complete factory assembled panel• Dummy plugs in unused cable entries• Dummy plugs in unused front plate ports• Adapters ready in complete panel set

Fiber Patch Panel

Rosenberger HDCS® patch panel is designed for 19" EIA rack, and compatible with all common factory assembled or site-installed fiber cables.

Feature and Benefit• Patching and splicing• The panel surface is treated with electro-static spraying• Silk-screen printing for front plate labeling• 45° entry for back cable, flexible cabling from left and right side• Aluminum or steel material available

• Sliding-type and fixed-type available• Standard black and other colors available• Panel accessories can be ordered separately

• 4 installation screws and caged-nuts as mounting kit• Cable gland & guiding clip• Splice trays included for complete panel set

Fixed-type:483 x 250 x 1HU (mm) and 483x 250 x 2HU (mm)

Page 53: FIBER OPTICS AND DATA COMMUNICATIONrosenberger.co.kr/data/(카탈로그) FTTA-Fiber to the... · 2016-12-31 · FIBER OPTICS AND DATA COMMUNICATION solution for wireless cellular

52

High Density VelaTM Modular Fiber Patch Panel

Specification

Dimension 483mm x 509mm x 44.45mmMTP-LC Module Number of Fiber 12FSlots Number for MTP-LC Module 8Max. Number of Fiber 96F

MTP-LC Module Attenuation(Typical)Single-mode 0.5dBMulti-mode 0.4dB

Salt Mist Cyclic Test 24HInstallation Type Fixed type and sliding typeStorage Temperature -40°C ~ +70°COperation Temperature -20°C ~ +60°C

Module and Accessories

Ordering Information

Ordering Number DescriptionFiber Patch PanelCPB1-110-41 VelaTM 1HU Modular Fiber Patch Panel Fixed Type, Black, without ModuleCPB1-110-51 VelaTM 1HU Modular Fiber Patch Panel Pull-out, Black, without ModuleMTP-LC Module CPB2-251-12 VelaTM MTP -LC Module B, 12F, SMCPB2-253-12 VelaTM MTP -LC Module B, 12F, OM2CPB2-254-12 VelaTM MTP -LC Module B, 12F, OM3CPB2-255-12 VelaTM MTP -LC Module B, 12F, OM4Blind CoverCPB4-611-11 VelaTM Blind Cover

DescriptionRosenberger high density fiber optic patch panels are designed for 19" racks and compatible with common factory assembled or

on-site assembled cables, especially for Rosenberger factory pre-assembled cabling system.

ApplicationRosenberger distribution & splice fiber optic patch panel insures good management for the four critical elements of fiber optic cable: bend radius protection, cable routing path, cable access

and physical protection. Those four aspects directly affect the reliability, functionality and the operational cost of the network.

Feature and Benefit• Modular and ergonomic design with front and rear drawers for

ease of installation and maintenance• Installable with standard 19" EIA rack• Max. 96 fibers capacity in 8 modules (2 layer x 4 modules/layer) • 12-fiber capacity of each module

12F MTP-LC duplex VelaTM Modules VelaTM Blind Cover

• Fiber module accepts multimode 50/125μm OM2, 10G OM3, OM4 or a low water-peak singlemode fiber cable harness

• Rear cabling manager with layered design and pull-out rotation function

• Hidden draw-type label panel design

Page 54: FIBER OPTICS AND DATA COMMUNICATIONrosenberger.co.kr/data/(카탈로그) FTTA-Fiber to the... · 2016-12-31 · FIBER OPTICS AND DATA COMMUNICATION solution for wireless cellular

53

Copper Connectivity SolutionRosenberger has leading copper connectivity solution which covers data, video and voice transmission applica-tion in telecommunication and electronics industry. All kinds of copper cable assembly, terminal module, distribu-tion frame and box are available to help operators and other customers set up a high efficiency communication transmission network.

High quality product, technical consultancy and support, best lead time and excellent after-sales service are sup-ported by Rosenberger.

• D-Sub Series Cable Assembly • RJ45 Ethernet Cable Assembly • Ethernet Patch Panel • Balun Panel• LSA Module and Distribution Unit • Other Customized Solution

Page 55: FIBER OPTICS AND DATA COMMUNICATIONrosenberger.co.kr/data/(카탈로그) FTTA-Fiber to the... · 2016-12-31 · FIBER OPTICS AND DATA COMMUNICATION solution for wireless cellular

54

D-Sub Series Cable Assembly

Specification

Product Series Shell Size (mm) Current (A) Wire Size (AWG) Contact Styles

Standard Density 9, 15, 25, 37, 50 5 28-18 Solder or Crimp

High Density 15, 26, 44, 62, 78 2 28-22 Solder or Crimp

DescriptionRosenberger provides different forms of D-sub cable assembly whice are to be widely used for data transmission between communication and control equipments.

Application• Cellular base station• Network switching• Transmission• Routers

Feature and Benefit• Applicable to various equipments and interfaces • Series of standard density and high density • Standard or customized cable

• Multiplexers• Mainframes• Engineering Workstations• Computers/Printers/Scanners

• Small to large size with different pins • Easy to install and unload without specialized tooling• 100% factory assembled and tested

Page 56: FIBER OPTICS AND DATA COMMUNICATIONrosenberger.co.kr/data/(카탈로그) FTTA-Fiber to the... · 2016-12-31 · FIBER OPTICS AND DATA COMMUNICATION solution for wireless cellular

55

RJ45 Ethernet Cable AssemblyCAT5e Patch Cord

DescriptionRosenberger CAT5e patch cord is used for network cabling transmission of voice, data and video signals. It supports current high-bandwidth network applications and is especially suitable to IEC 11801 Class D standard requirements.

Feature and Benefit• Designed for both unshielded and shielded cabling system• Comply with Fluke DTX-1800 / TIA568C.2 patch cord standard

and 100% factory tested• Adopt arc-shaped snagless boot design for elastic latch protection• Utilizing flexible stranded patch cable • Connector contacts 50μ” gold plated minimizing contact resistance

SpecificationElectrical Performance

Frequency(MHz)

NEXT (dB) RL(dB)2m Cord 5m Cord 10m Cord

1 65.0 65.0 65.0 19.8

4 62.3 61.5 60.4 21.6

8 56.4 55.6 54.7 22.5

10 54.5 53.7 52.8 22.8

16 50.4 49.8 48.9 23.4

20 48.6 47.9 47.1 23.7

25 46.7 46.0 45.3 24.0

31.25 44.8 44.2 43.6 23.0

62.5 39.0 38.5 38.1 20.0

100 35.1 34.8 34.6 18.0

Application• VoIP• ISDN• Token ring• 100 Mbps TP-PMD

• Outer jacket PVC or LSZH • Different colored cable jacket option• Flexible ladder-shaped boot design provides better cable

bending protection

• Analog and digital video• TR-16 Active and Passive• 155 Mbps /622 Mbps ATM• 10BASE-T/100BASE-TX Fast Ethernet

Page 57: FIBER OPTICS AND DATA COMMUNICATIONrosenberger.co.kr/data/(카탈로그) FTTA-Fiber to the... · 2016-12-31 · FIBER OPTICS AND DATA COMMUNICATION solution for wireless cellular

56

RJ45 Ethernet Cable AssemblyCAT6 Patch Cord

SpecificationElectrical Performance

Frequency(MHz)

NEXT (dB) RL(dB)2m Cord 5m Cord 10m Cord

1 65.0 65.0 65.0 19.8 4 65.0 65.0 65.0 21.6 8 65.0 65.0 64.8 22.5 10 65.0 64.5 62.9 22.8 16 62.0 60.5 59.0 23.4 20 60.1 58.6 57.2 23.7 25 58.1 56.8 55.4 24.0

31.25 56.2 54.9 53.6 23.0 62.5 50.4 49.2 48.1 20.0 100 46.4 45.3 44.4 18.0 125 44.5 43.5 42.7 17.0150 43.0 42.1 41.4 16.2175 41.8 40.9 40.2 15.5200 40.6 39.8 39.3 15.0 225 39.7 38.9 38.4 14.5250 38.8 38.1 37.6 14.0

DescriptionRosenberger CAT6 patch cord is used for network cabling transmission of voice, data and video signals. It supports current high-bandwidth network applications, and is especially suitable to IEC 11801 Class E standard requirements.

Application• VoIP• ISDN• Token ring• 100 Mbps TP-PMD

Feature and Benefit• Designed for both unshielded and shielded cabling system• Comply with Fluke DTX-1800 / TIA568C.2 patch cord standard

and 100% factory tested• Adopt arc-shaped snagless boot design for elastic latch protection• Utilizing flexible stranded patch cable • Connector contacts 50μ” gold plated minimizing contact resistance

• Analog and digital video• TR-16 Active and Passive• 155 Mbps /622 Mbps /1.2 Gbps ATM• 10BASE-T/100BASE-TX Fast /1000BASE-TX Gigabit Ethernet

• Outer jacket PVC or LSZH • Different colored cable jacket option• Flexible ladder-shaped boot design provides better cable

bending protection

Page 58: FIBER OPTICS AND DATA COMMUNICATIONrosenberger.co.kr/data/(카탈로그) FTTA-Fiber to the... · 2016-12-31 · FIBER OPTICS AND DATA COMMUNICATION solution for wireless cellular

57

RJ45 Ethernet Cable AssemblyCAT6A Patch Cord

Feature and Benefit• Designed for both unshielded and shielded cabling system• Comply with Fluke DTX-1800 / TIA568C.2 patch cord standard

and 100% factory tested• Adopt arc-shaped snagless boot design for elastic latch protection• Utilizing flexible stranded patch cable • Connector contacts 50μ” gold plated minimizing contact resistance

DescriptionRosenberger CAT6A patch cord is used for network cabling transmission of voice, data and video signals. It supports current high-bandwidth applications, and is especially suitable IEC 11801 to Class EA standard requirements.

Application• VoIP• SDN• Token ring• 100 Mbps TP-PMD• Analog and digital video

• TR-16 Active and Passive• 155 Mbps /622 Mbps /1.2 Gbps ATM• 10BASE-T/100BASE-TX Fast /1000BASE-TX Gigabit

Ethernet/10Gbase-T Gigabit Ethernet

SpecificationElectrical Performance

Frequency(MHz)

NEXT (dB) RL(dB)2m Cord 5m Cord 10m Cord

1 65.0 65.0 65.0 19.8

4 65.0 65.0 65.0 21.6

8 65.0 65.0 64.8 22.5

10 65.0 64.5 63.0 22.8

16 62.0 60.5 59.1 23.4

20 60.1 58.6 57.3 23.7

25 58.1 56.8 55.4 24.0

31.25 56.2 54.9 53.6 23.0

62.5 50.4 49.2 48.1 20.0

100 46.4 45.4 44.5 18.0

200 40.7 39.9 39.3 15.0

250 38.9 38.1 37.7 14.0

300 36.2 35.9 35.8 12.8

400 31.9 32.1 32.5 10.9

500 28.4 29.0 29.8 9.5

• Outer jacket PVC or LSZH • Different colored cable jacket option• Flexible ladder-shaped boot design provides better cable

bending protection

Page 59: FIBER OPTICS AND DATA COMMUNICATIONrosenberger.co.kr/data/(카탈로그) FTTA-Fiber to the... · 2016-12-31 · FIBER OPTICS AND DATA COMMUNICATION solution for wireless cellular

58

Type Description Specification

Multi-RJ45

8 Pair 120Ω PCM cable assembly is used for the serial transmission of data with good EMI performance, low bit-error and steady transmission rate.

Parts• Connector: RJ45 8P8C connector (shielded)• Cable: AWG 26 120Ω 8-pairAssembly• Insulation resistance ≥100MΩ• Dielectric strength AC, 250V, 1sec

Multi-RJ45

16 Pair 120Ω PCM cable assembly is used for the serial transmission of data with good EMI performance, low bit-error and steady transmission rate.

Parts• Connector: RJ45 8P8C connector (shielded)• Cable: AWG 26 120Ω 8-pairAssembly• Insulation resistance ≥100MΩ• Dielectric strength AC, 250V,1sec

BT43 (SMZ)

RS BT43 straight single cable assembly connects to DDF or communication switching equipment for transferring the digital signals.

Parts• Connector: BT43 75Ω connector• Cable: RS Multi 8*Coax CableAssembly• Insulation resistance ≥100MΩ• Dielectric strength AC, 250V, 1sec

TQ Straight

RS E1/T1 120Ω Cab le Assembly prov ides the d ig i ta l t ransmiss ion between communication equipments.

Parts• Connector: 4*TQ connector, 120Ω• Cable: AWG 26 120Ω 8-pairAssembly• Dielectric strength AC, 250V, 1sec

SCSI

SCSI PCM cable assembly provides the d ig i ta l t ransmiss ion between communication equipments. High compact design with metal shell for good EMI performance.

Parts• Connector: MDR IDC Plug 36Pin, Male• Shell: MDR Metal Junction shell 180°exit• Cable: AWG26 120Ω SFTP PCM CableAssembly• Insulation resistance ≥100MΩ• Dielectric strength AC, 250V, 1sec

SCSI

MDR68-MDR68 with IP seal cable a s s e m b l y p r o v i d e s t h e d i g i t a l transmission between communication equipments. It can be used in outdoor enviroment with good water/dust proof performance.

Parts• Connector: MDR 68Position, Male• Shell: MDR metal junction shell• Cable: AWG26 100Ω SFTP PCM Cable,

Halogen free, BlackAssembly• Insulation resistance ≥10MΩ• Dielectric strength AC, 250V, 1sec

Customized Assembly

Page 60: FIBER OPTICS AND DATA COMMUNICATIONrosenberger.co.kr/data/(카탈로그) FTTA-Fiber to the... · 2016-12-31 · FIBER OPTICS AND DATA COMMUNICATION solution for wireless cellular

59

Type Description Specification

Mini SNAP

Mini SNAP cable assembly is widely used i n au toma t i on con t r o l and communication industry.Push-pull self-locking results safe and quick connection or release.

Parts• Connector: Mini SNAP 4Pin Female• Cable: SEYVP 1*2/2*0.4 120ΩAssembly• Insulation resistance ≥100MΩ• Dielectric strength AC, 250V, 1sec

RJ45- coax 1.0/2.3

This cable assembly is used for signal transmission. One end is RJ45 plug with seal boot, and the other end is Coax 1.0/2.3 plug with seal boot.It can be used in outdoor enviroment with good water/dust proof performance..

Parts• Connector: RJ45 8P8C with seal boot• Connector: 1.0/2.3 straight plug with seal

boot, 75 Ohm• Cable 1: Cat.5e 24AWG*4P SFTP • Cable 2: RG179Assembly• Insulation resistance ≥20MΩ• Dielectric strength AC, 250V,1sec

Emily-RJ45 Socket

Emily-RJ45 signal cable assembly combines signal and power transmission in one connector system.

Parts• Connector A&B: Emily connector, Female• Cable: 30AWG 6PR parallel cable, LSZHAssembly• Insulation resistance ≥10MΩ• Dielectric strength AC, 250V, 1sec

Emily- Emily

Emily cable assembly combines signal and power transmission in one connector system.

Parts• Connector A&B: Emily connector, Female• Cable: 30AWG 6PR parallel cable, LSZHAssembly• Insulation resistance ≥10MΩ• Dielectric strength AC, 250V, 1sec

Densi Shield

This cable assembly supports the transmission of high-speed ser ial differential signals. It combines high density, mechanical robustness and PCB assembly with excellent shielding and signal integrity performance.

Parts• Connector: Densi-shield I/O Plug• Cable: AWG26 100Ω 4P SF/UTP, LSZHAssembly• Insulation resistance ≥5MΩ• Dielectric strength AC, 250V, 1sec

Page 61: FIBER OPTICS AND DATA COMMUNICATIONrosenberger.co.kr/data/(카탈로그) FTTA-Fiber to the... · 2016-12-31 · FIBER OPTICS AND DATA COMMUNICATION solution for wireless cellular

60

CAT5e Modular Patch Panel

Application• 10baseT Ethernet• 100baseTX Fast Ethernet• 155Mbit ATM• 622Mbit ATM• TR-16 Active• TR-16 Passive

Feature and Benefit• Exceed the specification of TIA 568-C. 2 Category 5e requirements • Outstanding performance including IL, NEXT/FEXT and RL guaranteeing good channel performence• Delivered with plastic cable management bar, installation screws and labeling system• Unshielded and shielded option• 24-port or 48-port per height unit (HU)

Specification

Material Electrical Property

Front Pane Steel, powder coating Current Rating 1.5 AMP

PlasticHigh impact flame retardant plastic, UL94V-0 rated

Contact Resistance 20MΩ Max.

Contact Phosphor bronze C5210EH Insulation Resistance 500MΩ Min.

Contact PlatingGold plating 50μ" over nickel plating 50~100μ"

Dielectric Strength 750V AC RMS 60Hz 1MIN

Mechanical Property

Plug Insertion Life ≥750 times

Plug Retention Force ≥30 Lbs

Temperature Range -40°C to +70°C

Ethernet Patch PanelDescriptionRosenberger Ethernet modular patch panel is designed for both unshielded and shielded cabling system with excellent transmission performance, and which are compatible with all Rosenberger HDCS® modules. It has extremely high flexibility, adaptability and most compact design for supporting up 48 ports per height unit (HU). Rosenberger develops and supplies all levels

of Ethernet patch panel including for supporting CAT5e, CAT6 and CAT6A performance transmission as per IEC 11801 and TIA-568-C.2 standards. Many of Rosenberger Ethernet patch panels are tested and certified by ETL-USA laboratory and other 3rd

parties.

Page 62: FIBER OPTICS AND DATA COMMUNICATIONrosenberger.co.kr/data/(카탈로그) FTTA-Fiber to the... · 2016-12-31 · FIBER OPTICS AND DATA COMMUNICATION solution for wireless cellular

61

Specification

Material Electrical Property

Front Panel Steel, powder coating Current Rating 1.5 AMP

PlasticHigh impact flame retardant plastic, UL94V-0 rated

Contact Resistance 20MΩ Max.

Contact Phosphor bronze C5210EH Insulation Resistance 500MΩ Min.

Contact PlatingGold plating 50μ" over nickel plating 50~100μ"

Dielectric Strength 750V AC RMS 60Hz 1MIN

Mechanical Property

Plug Insertion Life ≥750 times

Plug Retention Force ≥30 Lbs

Temperature Range -40°C to+70°C

Application• 10baseT Ethernet• 100baseTX Fast Ethernet• 1000baseTX Gigabit Ethernet• 155Mbit ATM• 622Mbit ATM• TR-16 Active• TR-16 Passive

Feature and Benefit• Exceed the specification of TIA 568-C. 2 Category 6 requitments• Outstanding performance including IL, NEXT/FEXT and RL guaranteeing good channel performence• Delivered with plastic cable management bar, installation screws and labeling system• Unshielded and shielded option• 24-port or 48-port per height unit (HU)

Ethernet Patch PanelCAT6 Modular Patch Panel

Page 63: FIBER OPTICS AND DATA COMMUNICATIONrosenberger.co.kr/data/(카탈로그) FTTA-Fiber to the... · 2016-12-31 · FIBER OPTICS AND DATA COMMUNICATION solution for wireless cellular

62

Ethernet Patch PanelCAT6A Modular Patch Panel

Application• 10baseT Ethernet• 100baseTX Fast Ethernet• 1000baseTX Gigabit Ethernet• 10Gbase-T Gigabit Ethernet• 155Mbit ATM• 622Mbit ATM• 1.2 Gbit ATM• TR-16 Active/ Passive

Feature and Benefit• Exceed the specification of TIA 568-C. 2 Category 6A requirements• Outstanding performance including IL, NEXT/FEXT and RL guaranteeing good channel performence• Delivered with plastic cable management bar, installation screws and labeling system• Unshielded and shielded option• 24-port per height unit (HU)

Specification

Material Electrical Property

Front Panel Steel, powder coating Current Rating 1.5 AMP

PlasticHigh impact flame retardant plastic, UL94V-0 rated

Contact Resistance 20MΩ Max.

Contact Phosphor bronze C5210EH Insulation Rresistance 500MΩ Min.

Contact PlatingGold plating 50μ over nickel plating 50~100μ

Dielectric Strength 750V AC RMS 60Hz 1MIN

Mechanical Property

Plug Insertion Life ≥750 times

Plug Retention Force ≥30 Lbs

Temperature Range -40°C to+70°C

Page 64: FIBER OPTICS AND DATA COMMUNICATIONrosenberger.co.kr/data/(카탈로그) FTTA-Fiber to the... · 2016-12-31 · FIBER OPTICS AND DATA COMMUNICATION solution for wireless cellular

63

Feature and Benefit• Connects 75Ω dual coax to 120Ω twisted pair (or vice versa)• Bi-directional signal conversion according to ITU-T G.703• Data rates up to 2.048 Mbps• Low profile design

Balun PanelBalun Panel BNC to RJ45

DescriptionBNC to RJ45 impedance matching balun panel provides 75Ω coax (BNC connector) to 120Ω twisted pair (RJ45 connector) conversion for 16 E1 channels (Tx and Rx). The panel conforms to

ITU-T G.703, matching the impedance and signal characteristics of up to 32 unbalanced 75Ω coax connections with up to 16 balanced 120Ω twisted pair connections.

ApplicationThe balun panel can be used for T1/E1/CPE network transmission equipment and other applications.The balun panel can provide

Specification

PartsCoaxial Connector Female BNC, 32pcsTwisted Pair Connector Female shielded RJ45, 16pcsPanel 19", Steel, Zinc sealed and power coated, blackElectrical Data At 20°CInsertion Loss ≤ 0.35dBCross Talk @1~100MHz ≥ 50dBReturn Loss ≥ 18dBInsulation Resistance ≥ 100MΩOperating ConditionMatching Impedance 75Ω unbalanced coaxial to 120Ω balanced twisted pair connectionsBit Rate 2Mbit/s(E1) ITU-T G.703Environmental DataTemperature Range -40°C to +85°C2011/65/EC (RoHS) Compliant

120Ω G.703 service whereas customers retaining 75Ω CPE hardware and vice versa

• Mounts in standard 19" rack (1HU)• No power supply required• Female coax BNC connectors

Page 65: FIBER OPTICS AND DATA COMMUNICATIONrosenberger.co.kr/data/(카탈로그) FTTA-Fiber to the... · 2016-12-31 · FIBER OPTICS AND DATA COMMUNICATION solution for wireless cellular

64

Balun PanelBalun Panel Coax to IDC

DescriptionThe rack mounting Balun Panel converts 16 G.703 E1 or E2 circuits from unbalanced 75Ω coaxial to balanced 120Ω twisted pair transmissions. Modular construction allows the user to hot swap modules for other bit rates, functions or interfaces.G.703/G.704 toolless insulating displacement connecting (IDC)

baluns are impedance matching 75Ω coax to 120Ω single-conductor connections. Various industry standard types of coaxial connectors (75Ω) are available including male and female combinations of BNC, 1.6/5.6, 1.0/2.3, and Type 43.

Feature and Benefit• Convert 75Ω Coax to 120Ω twisted pair--resolves impedance

mismatch between twisted pair and coax cabling• Ultra-miniature IDC balun providing maximum density• Industry standard coax connectors including BNC, 1.6/5.6,

1.0/2.3 and Type 43 are available

ApplicationA bi-directional device requiring no external power which connects telecommunications equipment with mismatching interfaces or

facilitates the conversion from coaxial to twisted pair distribution wiring.

• Mounts in standard 19" rack (1HU)• Low insertion loss meeting ITU-T (CTR-12) G.703 standards• No power supply required

Page 66: FIBER OPTICS AND DATA COMMUNICATIONrosenberger.co.kr/data/(카탈로그) FTTA-Fiber to the... · 2016-12-31 · FIBER OPTICS AND DATA COMMUNICATION solution for wireless cellular

65

Specification

Parts

Type 1.0/2.3 female to IEC169-29

Coaxial Connector

Body Material Brass gold plated

Pin Material Beryllium copper, plated cu/Ni5/Au1.25

Insulator Material Teflon

Mating cycles 500min

IDC Connector

Wire Conductor Size Φ0.4 to Φ0.63mm

Insulation 0.7 to 1.1mm

Moulding Material Polycarbonate White

Mating Cycles 50min

Coaxial IDC Moulding Material PC, Black

Panel Size Standard 19" rack mountable

Material Steel, Zinc sealed and power coated black

Electrical Data At 20°C

Insertion Loss ≤0.15dB from 51KHz to 3.072MHz(2M bit/s)

≤0.20dB from 211KHz to 12.673MHz(8M bit/s)

Return Loss Exceeds G.703 requirements by >13dB for 2M bit/s by >8dB for 8M bit/s

Pulse Shape Exceeds G.703 requirements for 2Mbit/s and 8Mbit/s

Cross Talk >65dB from 211KHz to 12.673MHz between channel

>55dB for adjacent module contacts

Isolation Voltage >250V DC

Operating Condition

Matching Impedance 75Ω unbalanced coaxial to 120Ω balanced twisted pair connections

Bit Rate 2Mbit/s(E1) and 8Mbit/s(E2) ITU-T G.703 Line code

Signal Level 2.37V nominal peak voltage at the coaxial end per G.703

Environmental Data

Temperature Range -40 °C to +85 °C

2011/65/EC (RoHS) Compliant

Page 67: FIBER OPTICS AND DATA COMMUNICATIONrosenberger.co.kr/data/(카탈로그) FTTA-Fiber to the... · 2016-12-31 · FIBER OPTICS AND DATA COMMUNICATION solution for wireless cellular

66

LSA Module and Distribution Unit LSA Termination Module

Feature and Benefit• 5, 8, 10 pairs disconnection and connection module available• Folded double–layer and double-slot terminal with silver–plated

surface• Lower contact resistance and high pull off force

DescriptionRosenberger LSA module is specially designed for wall wounted box and MDF rack. It has connection and disconnection models, and is convenient to be used for PCM cable connection. It is suitable for use in all communication networks such as DSL and IP network.

Application• Main distribution frames• Data and PABX distribution• Cross-connection cabinets

• Internal and external distribution point• VDSL2-capable• Outdoor enclosures with restricted space for cable termination

SpecificationMechanical Property

Housing Material PBT fire-retardant, UL94V-0

Contact Material Phosphor bronze, C5191H

Plating 200μ’’ silver plating over nickel plating

Allowed Wire 0.32-0.8mm

Contact Pin Life ≥ 200 times

Pull Off Force ≥ 25N

Electrical Characteristics

Voltage Rating 12 VAC

Current Rating 1.5AMP

Insulation Resistance ≥ 1000Mohm@ 500VDC

Contact Resistance Between Terminals ≤3 milliohm

Dielectric Strength 1000V 1min, (45~60) Hz

• Aligning slot for each pair of wiring• Plastic shield over the terminals prevents from getting hurt• Clear identification mark for each pair of wiring

Page 68: FIBER OPTICS AND DATA COMMUNICATIONrosenberger.co.kr/data/(카탈로그) FTTA-Fiber to the... · 2016-12-31 · FIBER OPTICS AND DATA COMMUNICATION solution for wireless cellular

67

LSA Module and Distribution UnitLSA Distribution Box

Specification

Box Capacity 50 pair 100 pair 200 pair

Box Size 320x240x110mm 320x320x110mm 400x600x110mm

Box Material ABS, thickness 3mm

Frame Material Stainless steel

Modules Endurance 100 Cycles (Min)

Operating Temperature -40°C to +65°C

2011/65/EU (RoHS) Compliant

Flammability Rating UL94V-0

Waterproof Performance IP54

DescriptionThe LSA distribution box is designed for both indoor and outdoor application, and can be mounted on the wall. There is a mounting frame for fixing 2/10 or 2/8 LSA connection module or compatible disconnection module inside the box.

ApplicationIt is suitable for PCM cable connection in all communication networks such as DSL and IP network.

Feature and Benefit• Supplied with or without LSA modules• Support up to 20pcs of LSA module or other capacity• Lockable design• Over-voltage protection (OVP) device option• Customized design available on request

Page 69: FIBER OPTICS AND DATA COMMUNICATIONrosenberger.co.kr/data/(카탈로그) FTTA-Fiber to the... · 2016-12-31 · FIBER OPTICS AND DATA COMMUNICATION solution for wireless cellular

68

LSA Module and Distribution UnitLSA Distribution Frame

Specification

Material

Frame Material Stainless steel

Thickness 1.5mm

Terminal Material PBT fire-retardant ,UL94V-0

Contact Material Phosphor bronze

Plating 200μ’’ silver plating over nickel plating

Allowed Wire 0.32-0.8mm

Contact Pin Life ≥ 200 times

Pull Off Force ≥ 25N

Electrical Characteristics

Voltage Rating 12 VAC

Current Rating 1.5AMP

Insulation Resistance ≥ 1000Mohm@ 500VDC

Contact Resistance Between Terminals ≤3 milliohm

Dielectric Strength 1000V 1min, (45~60) Hz

DescriptionRosenberger LSA distribution frame is very convenient to be used for connecting and distributing PCM cables, which is designed in a shape of ESTI 3HU for installing on a standard 19” open frame or rack. The distribution frame can be installed with up to 15pcs of LSA terminal module providing 150-pair wiring and transmission capacity.

It is suitable for PCM cable connection in all communication networks such as DSL and IP network.

Feature and Benefit• Termination block with 120Ω characteristic impedance• Instal led on standard 19" open frame for better cable

management• 3HU frame is suitable for small size exchange office

Application

• Clear and tidy cabling• 50 pairs, 100 pairs, 150 pairs capacity available• Installation accessory attached

Page 70: FIBER OPTICS AND DATA COMMUNICATIONrosenberger.co.kr/data/(카탈로그) FTTA-Fiber to the... · 2016-12-31 · FIBER OPTICS AND DATA COMMUNICATION solution for wireless cellular

69

Power Cable AssemblyMany of today’s communication equipment including remote radio head (RRH) require DC power supply with different voltage rating and connectivity interface. Particularly for remote radio head (RRH) application which re-quires power-to-the-antenna (PTTA), Rosenberger has a power design tool including calculation formula to tell following questions.

• What is the maximum allowable power consumption of RRH load with a desired cable design?• What is the required cable configuration including conductor cross section of DC power cable at a certain

tower height?• What is the maximum allowed cable length between RRH and power supply unit with a specified cable

cross section and RRH (power consumption level)?

Page 71: FIBER OPTICS AND DATA COMMUNICATIONrosenberger.co.kr/data/(카탈로그) FTTA-Fiber to the... · 2016-12-31 · FIBER OPTICS AND DATA COMMUNICATION solution for wireless cellular

70

Specification

Parts

Connector A D-sub body

2W2, 2V2, 3W3, 3V3, 4W4, 4V4, 5W5, 8W8…

Connector B D-sub body

2W2, 2V2, 3W3, 3V3, 4W4, 4V4, 5W5, 8W8…

Connector Material Brass, gold plated over nickel

Back Shell Zinc Alloy, Matt nickel plated

Cable Power Cable, Shielded, LSZH or PVC Jacket

Connector Electrical Characteristics

Current Rating 10A, 20A, 30A, 40A

Contact Resistance 10MΩ Max.

Insulation Resistance 5000MΩ, Min.

Dielectric Withstanding 1000V AC

Environmental Data

Installation Temperature -10 °C to +65 °C

Operation Temperature -20 °C to +75 °C

2011/65/EU (RoHS) Compliant

Indoor D-sub Type High Power Cable Assembly

DescriptionRosenberger D-sub type cable assembly is used for high-power DC transmission in an indoor enviroment. The cable assembly has multi-pin D-sub connectors at both ends with male or female terminals.

ApplicationIdeal as an input/output of D-sub power interface. The high quality D-sub connector has mixed contact sizes for signal, power, coax, thermocouple and high voltage applications.

Feature and Benefit• Power supply between transmission equipment• High Power Connector/ Combo D-sub connector• Support up to 40A high current

Page 72: FIBER OPTICS AND DATA COMMUNICATIONrosenberger.co.kr/data/(카탈로그) FTTA-Fiber to the... · 2016-12-31 · FIBER OPTICS AND DATA COMMUNICATION solution for wireless cellular

71

Specification

Parts

Connector ET Power connector

Power Contact Copper alloy with coating

Cable Conductor Size 16AWG, 14AWG, 12AWG, 10AWG

Cable Conductor Structure Stranded / Solid tinned copper

Cable Jacket Halogen free, Black

Electrical Characteristics

Current Max 30A per contact

Environmental Data

Installation Temperature -10 °C to +65 °C

Operation Temperature -40 °C to +70 °C

2011/65/EU (RoHS) Compliant

Indoor ET 2-Pole Power Cable Assembly

DescriptionThe ET 2 pole power cable assembly is used for power distribution units with small form connector. The ET connector is a low loss, highly reliable and cost effective solution for cable-to-pcb application.

Application• Power distribution• Cellular base station sites• Computer servers and storage systems• Industrial electronic equipment cabinets

Feature and Benefit• High reliability• Low profile right angle • Right-angle and vertical mounts available for ET connector• 16AWG, 14AWG, 12AWG, 10AWG wire cables for option• Up to 30 Amps per contact

Page 73: FIBER OPTICS AND DATA COMMUNICATIONrosenberger.co.kr/data/(카탈로그) FTTA-Fiber to the... · 2016-12-31 · FIBER OPTICS AND DATA COMMUNICATION solution for wireless cellular

72

DescriptionMany of today’s communication equipment including remote radio head (RRH) require DC power supply with different voltage rating and connection interface. Rosenberger provides such power cable assembly in conjunction with hybrid FTTA solution, which is usually terminated at one end with 2-pole or 3-pole outdoor power connector for connecting with hybrid cable and the other end left open.

ApplicationMost applicable for Power-To-The-Antenna (PTTA) requirements for transmitting the DC power up to RRH by connecting with hybrid cable assembly.

Outdoor IP67 Power Cable Assembly

Specification

PartsNumber of Connector Poles 2 or 3 Cable Conductor 4mm2 (12AWG) 6mm2 (10AWG)Cable Ingress Protection IP67 Cable Jacket Material PVC, UV-resistant, BlackCable Braid Bare copper Cable Diameter 9.2mm 11.2mm

Cable Bending Radius Operation 12×outer diameter Installation 6×outer diameter

Electrical CharacteristicsDC resistance of conductor ≤ 3.30Ω/kmInsulation resistance ≥ 5 MΩ•km

Rating VoltageWire to Earth 0.6 kVWire to Wire 1 kV

Environmental DataOperation Temperature -40 °C to +70 °C Installation Temperature -20 °C to +60 °C 2011/65/EU (RoHS) Compliant

Feature and Benefit• Compatible with EasyLinkTM hybrid trunk• Terminated with a IP67 connector and blunt cut on the RRH side• Pluggable power supply interface• 12AWG or 10AWG gauge wire for option• Strong tensile and crush capability

Page 74: FIBER OPTICS AND DATA COMMUNICATIONrosenberger.co.kr/data/(카탈로그) FTTA-Fiber to the... · 2016-12-31 · FIBER OPTICS AND DATA COMMUNICATION solution for wireless cellular

73

Outdoor IP65 Power Cable Assembly

Feature and Benefit• Provides contacts for power distribution and power control• Rugged Blind-Mate connector system• Pluggable power supply interface• Flexible Power crimp-to-wire terminations accommodate• 8AWG, 10AWG and 12AWG wire for option• Stamped and selectively plated power contacts provide a cost effective solution

Specification

Parts

Connector Type Multi-beam 2P power connector with seal boot, IP65

Connector Contacts Material Copper based alloy

Connector Housing Material Glass-filled high temperature nylon, black

Cable Conduct Size 8 AWG 10 AWG 12 AWG 14 AWG

Cable Conduct Structure Stranded bare copper

Cable Jacket Material PVC, UV-resistant, Black

Electrical Characteristics

Current Rating 45A 35A 25A 20A

Voltage Rating 105C, 600V

Dielectric Strength DC 1500V, 1min

Insulation Resistance ≥20 MΩ

Dielectric Strength AC 500V, 1sec

Environmental Data

Installation Temperature -15 °C to +60 °C

Operation Temperature -35 °C to +80 °C

2011/65/EU (RoHS) Compliant

DescriptionMany of today’s communication equipment including remote radio head (RRH) require DC power supply with different voltage rating and connection interface. Rosenberger provides such multi-beam 2-pole power cable assembly in conjunction with hybrid FTTA solution, which is usually terminated at one end with 2-pole multi-beam connector for connecting with RRH and the other end left open.

ApplicationMost applicable for Power-To-The-Antenna (PTTA) requirements for transmitting the DC power up to RRH by connecting with hybrid cable assembly.

Page 75: FIBER OPTICS AND DATA COMMUNICATIONrosenberger.co.kr/data/(카탈로그) FTTA-Fiber to the... · 2016-12-31 · FIBER OPTICS AND DATA COMMUNICATION solution for wireless cellular

74

Fiber Optic ConnectivityA fiber optic connector is a disconnectable device used to connect a fiber to a source, detector or another fiber. It is targeted to be designed for easy connecting and disconnecting many times. Connection by fiber optic con-nectors couples light from one component to another with as little loss of optical power as possible, since the interconnection of various components of a fiber optic network system is a vital part of system performance. Rosenberger, with over 20 years of experience, has designed and supplied various fiber optic connectors to the market with desirable features including low loss, easy installation, high repeatability, consistency quality and cost-effective material. Particularly for today and tomorrow’s wireless communication network and cellular sites, Rosenberger can provide all industry standard and specialized fiber connectivity solution to fulfill high perfor-mance requirements.

Page 76: FIBER OPTICS AND DATA COMMUNICATIONrosenberger.co.kr/data/(카탈로그) FTTA-Fiber to the... · 2016-12-31 · FIBER OPTICS AND DATA COMMUNICATION solution for wireless cellular

75

DescriptionUsing as flexible connection joint in fiber optic network, where there is device with a fiber optic interface installed in outdoor or harsh environment. Typical is for mobile communication (FTTA), broadcast, smart-grid cabling application.

Rosenberger Multi-fiber Connector (RMC™)

Specification

Standard IEC 61753-1 Cat. E

Housing Material Nickel-plated brass

Ferrule Material PPS

Operating Temperature -40°C~+80°C (dependent on cable type)

Ingress Protection (Mated) IP67 (IEC 60529)

Mechanical Resistance >600N

Mating Cycles >=500

Suitable Cables (mm) D2.0/ D6.0/ D7.0

Fiber Types OS2, OM1, OM2, OM3, OM4

2011/65/EU(RoHS) Compliant

Feature and Benefit• Multi-fibers connector, 4/6/8/12/24 fibers are available• Support singlemode and multimode • Robust connector system with screwed locking mechanism• Components of the N coaxial connector according to MIL-

PRF-39012 enable a conversion• With the standard panel cutout, the receptacle can easily

replace a coaxial connector type

• Mated or with attached protection cap, plug and receptacle are sealed according to IEC 60529 IP67

• Captive protection cap, plastic dust cap and metal cap without rope are available

• Cable connector (male/female) and flange connector (female) are available

Page 77: FIBER OPTICS AND DATA COMMUNICATIONrosenberger.co.kr/data/(카탈로그) FTTA-Fiber to the... · 2016-12-31 · FIBER OPTICS AND DATA COMMUNICATION solution for wireless cellular

76

DescriptionUsing as flexible connection joint in fiber optic network, where there is device with a fiber optic interface installed in outdoor or harsh environment. Typical is for mobile communication (FTTA), broadcast, smart-grid cabling application.

Rosenberger Quad Connector (RQC)

Specification

Standard IEC 61753-1 Cat. E

Housing Material Nickel-plated brass

Ferrule/Sleeve Material Zirconia ceramic

Operating Temperature -40°C~+125°C (dependent on cable type)

Ingress Protection (mated) IP67 (IEC 60529)

Mechanical Resistance >600N

Mating Cycles >=1000

Suitable Cables (mm) D4-D7 (Mini) breakout or D1.7 Simplex cable

Fiber Types OS2, OM1, OM2, OM3, OM4

2011/65/EU(RoHS) Compliant

Feature and Benefit• 4 fibers connector• Support singlemode and multimode • Robust connector system with screwed locking mechanism• Components of the N coaxial connector according to MIL-

PRF-39012 enable a conversion• With the standard panel cutout, the receptacle can easily

replace a coaxial connector type

• Mated or with attached protection cap, plug and receptacle are sealed according to IEC 60529 IP67

• Captive protection cap, plastic dust cap and metal cap without rope are available

• Cable connector (male/female) and flange connector (female) are available

Page 78: FIBER OPTICS AND DATA COMMUNICATIONrosenberger.co.kr/data/(카탈로그) FTTA-Fiber to the... · 2016-12-31 · FIBER OPTICS AND DATA COMMUNICATION solution for wireless cellular

77

Rosenberger Duplex Connector (RDC)

Specification

Standard IEC 61753-1 Cat. E

Housing Material Nickel-plated brass

Ferrule/Sleeve Material Zirconia ceramic

Operating Temperature -40°C~+125°C (dependent on cable type)

Ingress Protection (mated) IP67 (IEC 60529)

Mechanical Resistance >600N

Mating Cycles >=1000

Suitable Cables (mm) D4-D7 (Mini) breakout or D1.7 Simplex cable

Fiber Types OS2, OM1, OM2, OM3, OM4

2011/65/EU(RoHS) Compliant

Feature and Benefit• 2 fibers connector• Support singlemode and multimode • Robust connector system with screwed locking mechanism• Components of the N coaxial connector according to MIL-

PRF-39012 enable a conversion• With the standard panel cutout, the receptacle can easily

replace a coaxial connector type

• Mated or with attached protection cap, plug and receptacle are sealed according to IEC 60529 IP67

• Captive protection cap, plastic dust cap and metal cap without rope are available

• PC and APC are available• Cable connector (male/female) and flange connector (female)

are available

DescriptionUsing as flexible connection joint in fiber optic network, where there is device with a fiber optic interface installed in outdoor or harsh environment. Typical is for mobile communication (FTTA), broadcast, smart-grid cabling application.

Page 79: FIBER OPTICS AND DATA COMMUNICATIONrosenberger.co.kr/data/(카탈로그) FTTA-Fiber to the... · 2016-12-31 · FIBER OPTICS AND DATA COMMUNICATION solution for wireless cellular

78

Feature and Benefit• Standard LC duplex connector interface• Support singlemode and multimode • Robust connector system with bayonet locking mechanism• Support connection with SFP module• Easy manual installation• Waterproof, dust proof and corrosion resistant

Specification

Mating with ODVA connector From TE and Conec

Nut Material Aluminium alloy, black oxide treated

Housing Material PA

Gasket Material Silicon

Operating Temperature -40°C~+85°C (dependent on cable type)

Ingress Protection (mated) IP67 (IEC 60529)

Mechanical Resistance >600N

Mating Cycles >=1000

Suitable Cables (mm) D4-D7

Connector Type Standard LC duplex

2011/65/EU(RoHS) Compliant

DescriptionUsing as flexible connection joint in fiber optic network, where there is device with a fiber optic interface installed in outdoor or harsh environment. Typical is for mobile communication (FTTA), broadcast, smart-grid cabling application.

Rosenberger Efficient Connector (REC)

Page 80: FIBER OPTICS AND DATA COMMUNICATIONrosenberger.co.kr/data/(카탈로그) FTTA-Fiber to the... · 2016-12-31 · FIBER OPTICS AND DATA COMMUNICATION solution for wireless cellular

79

LC Loopback Connector

Description

Feature and Benefit• Standard LC duplex connector interface• Support singlemode and multimode individually • Packing sizes fit for small space application• Reliable protection for loopback fiber• Easy manual installation

Specification

Standard IEC 60754-20

Housing Material PEI

Ferrule Material Zirconica ceramic

Insertion Loss (Typical) Singlemode ≤0.5dB @1310nm&1550nm

Multimode ≤0.4dB @850nm&1300nm

Insertion Loss (Max.) Singlemode≤1.0dB @1310nm&1550nm

Multimode ≤0.7dB @850nm&1300nm

Operating Temperature -40~+75°C

Mating Cycles >=500

Flammability Rating UL 94-V0

2011/65/EU (RoHS) Compliant

Order Information

Part number Description

98E-118 LC Loopback, Singlemode, 9/125μm fiber

98E-119 LC Loopback, Multimode, 50/125μm fiber

98E-120 LC Loopback, Multimode, 62.5/125μm fiber

LC Loopback is with standard LC duplex connector interface, available both single mode and multimode version. It is to make both optical contacts connected together inside the packing which allows a self-test for device or a measurement of a link from one side. It can be used for trouble shooting in field and also can be used to make transceiver test in research and development labs.

Page 81: FIBER OPTICS AND DATA COMMUNICATIONrosenberger.co.kr/data/(카탈로그) FTTA-Fiber to the... · 2016-12-31 · FIBER OPTICS AND DATA COMMUNICATION solution for wireless cellular

80

LC Connector

Description

Feature and Benefit• Small Form Factor (SFF) single-fiber connector• Support singlemode and multimode • Simplex and duplex• Latched push-pull locking mechanism• Spring loaded ferrule, aligned in a slotted sleeve• Tuning possible• Dust caps are available• PC/UPC/APC is available

Specification

Standard IEC 61754-20

Housing Material PEI

Ferrule/Sleeve Material Zirconia ceramic

Operating Temperature -40°C~+85°C (dependent on cable type)

Mating Cycles >=1000

Suitable Cables (mm) D0.9-D3.0 or D5.0 with duplex connector

Fiber Types OS2, OM1, OM2, OM3, OM4

2011/65/EU(RoHS) Compliant

Using as flexible connection joint in fiber optic network, where there is devices with a fiber optic interface installed in an indoor enviroment. Typical is for mobile communication (FTTA), LAN, Data center network application.

Page 82: FIBER OPTICS AND DATA COMMUNICATIONrosenberger.co.kr/data/(카탈로그) FTTA-Fiber to the... · 2016-12-31 · FIBER OPTICS AND DATA COMMUNICATION solution for wireless cellular

81

SC Connector

Description

Feature and Benefit• Single-fiber connector• Support singlemode and multmode • Simplex and duplex• Push-pull locking mechanism• Spring loaded ferrule, aligned in a slotted sleeve• Tuning possible• Dust caps are available• PC/UPC/APC is available

Specification

Standard IEC 61754-4, EN 50377-4

Housing Material PEI

Ferrule/Sleeve Material Zirconia ceramic

Operating Temperature -40°C~+85°C (dependent on cable type)

Mating Cycles >=1000

Suitable Cables (mm) D0.9-D3.0 or D5.0 with duplex connector

Fiber Types OS2, OM1, OM2, OM3, OM4

2011/65/EU(RoHS) Compliant

Using as flexible connection joint in fiber optic network, where there is device with a fiber optic interface installed in an indoor enviroment. Typical is for mobile communication (FTTA), LAN, Data center network application.

Page 83: FIBER OPTICS AND DATA COMMUNICATIONrosenberger.co.kr/data/(카탈로그) FTTA-Fiber to the... · 2016-12-31 · FIBER OPTICS AND DATA COMMUNICATION solution for wireless cellular

82

MU Connector

Feature and Benefit• Single-fiber connector• Support singlemode and multimode • Simplex, duplex horizontal and vertical• Push-pull locking mechanism• Spring loaded ferrule, aligned in a slotted sleeve• Tuning possible• Dust caps are available• PC/UPC/APC are available

Specification

Standard IEC 61754-6; EN50377-10

Housing Material PEI

Ferrule/Sleeve Material Zirconia ceramic

Operating Temperature -40°C~+85°C (dependent on cable type)

Mating Cycles >=1000

Suitable Cables (mm) D0.9-D3.0

Fiber Types OS2, OM1, OM2, OM3, OM4

2011/65/EU(RoHS) Compliant

DescriptionUsing as flexible connection joint in fiber optic network, where there is device with a fiber optic interface installed in an indoor enviroment. Typical is for mobile communication (FTTA), LAN, Data center network application.

Page 84: FIBER OPTICS AND DATA COMMUNICATIONrosenberger.co.kr/data/(카탈로그) FTTA-Fiber to the... · 2016-12-31 · FIBER OPTICS AND DATA COMMUNICATION solution for wireless cellular

83

E2000TM Connector

Feature and Benefit• Single-fiber connector• Singlemode and multimode• Simplex, duplex and duplex-compact• Latched push-pull locking mechanism• Spring loaded ferrule, aligned in a slotted sleeve• Metal cap and plastic cap are available

Specification

Standard IEC 61754-15, EN 50377-8

Housing Material PEI

Ferrule/Sleeve Material Zirconia ceramic

Operating Temperature -40°C~+85°C (dependent on cable type)

Mating Cycles >=1000

Suitable Cables (mm) D0.9-D3.3, Diamond up to D3.5mm

Fiber Types OS2, OM1, OM2, OM3, OM4

2011/65/EU(RoHS) Compliant

DescriptionUsing as flexible connection joint in fiber optic network, where there is device with a fiber optic interface installed in an indoor enviroment. Typical is for mobile communication (FTTA), LAN, Data center network application.

Page 85: FIBER OPTICS AND DATA COMMUNICATIONrosenberger.co.kr/data/(카탈로그) FTTA-Fiber to the... · 2016-12-31 · FIBER OPTICS AND DATA COMMUNICATION solution for wireless cellular

84

Housing Material PA

Sealing Material Silicone

Tightening Torque Gland 3Nm

Operating Temperature -40°C~+70°C

Mating Cycles >25

Suitable Cable Diameters D4.5-D9

Pulling Axial >150N

Ordering Information

Part Number Description

98Z105-S0098Z105-S05

98Z105-S00/53 RFE - Protection cap plug

98Z105-S04 RFE - Coupler kit for RFE to RFE connection with LCD

98Z105-S90-XXX RFE – Extension tube

R99220107 RFE - Protection cap plug (P)

• For cable diameters from 4.5mm up to 9mm and the connectors with outer diameter of < 17.3mm. e.g. LC-Duplex, MTP®, RJ45 and USB

• Enables pre-assembling of cables or connecting to cables

• Easy to install by hand• Snap-on locking mechanism • Waterproof according to IP 67 • UV resistant

Rosenberger Fiber Enclosure (RFE)

Description

possible for outdoor use and applicable for small cells, radio links, RRHs, and distribution boxes.

Page 86: FIBER OPTICS AND DATA COMMUNICATIONrosenberger.co.kr/data/(카탈로그) FTTA-Fiber to the... · 2016-12-31 · FIBER OPTICS AND DATA COMMUNICATION solution for wireless cellular

85

Rosenberger Cable SystemsRosenberger Cable Systems develops, manufactures and supplies various outdoor, indoor and universal fiber optic cables for telecommunication industry, IT data center network, enterprise cabling network as well as many specialized cables for harsh environment applications. Rosenberger has supported remote radio Fiber-To-The-Antenna technologies by developing many cables with the most stringent specifications which are collaborated with world-leading network system vendors.

Page 87: FIBER OPTICS AND DATA COMMUNICATIONrosenberger.co.kr/data/(카탈로그) FTTA-Fiber to the... · 2016-12-31 · FIBER OPTICS AND DATA COMMUNICATION solution for wireless cellular

86

Cable StandardRosenberger fiber optic cable complies with one or several of the following international standards.

• DIN VDE 0888 • ITU-T G.651 to G.657

• DIN VDE 0472 • TIA-EIA 598-B

• IEC 60793 • Telcordia GR-20

• IEC 60794 • Telcordia GR-409

• IEC 60332-1/3

Pictograph

Flame-Retardant UV-Resistant UL Certification Waterproof

The outer sheath of the cable is self-extinguishing and not fire conductive.

The outer jacket of the cable is good performance on UVresistant

The cable is UL certification and applying with OFNR or OFNP grade

Water in the core can not spread in the longitudinal and transverse direction

Rodent- Retardant Enhanced Rodent- Retardant RoHS-Compliant

The cable is protested against damage from the rodent. The cable is protested against serious damage from the rodentThe cable is RoHS compliant according to 2011/65/EU (RoHS) and 2012/19/EU (WEEE)

Quality and Environment

A wide range of Rosenberger fiber optic cables are designed and manufactured with performance and future proofing in mind. Bandwidth and Attenuation are the key specification areas that ensure your fiber investment will stand the test of time. Internationally recognized standards have defined today’s level of performance. Rosenberger has selected a level of Attenuation and Bandwidth exceeds this level of performance for no significant cost penalty.

It is vital that any investment in a fiber networking strategy provides long-term performance and reliability for these evolving international standards which will continue to advance and develop. Rosenberger fiber optic cables provide this long-term support when installed and used in well designed systems. Rosenberger has ensured the performance and reliability by specifying key optical attributes in the cable design and manufacturing.

• Attenuation• Bandwidth• Fiber Geometry• Proof Test

Page 88: FIBER OPTICS AND DATA COMMUNICATIONrosenberger.co.kr/data/(카탈로그) FTTA-Fiber to the... · 2016-12-31 · FIBER OPTICS AND DATA COMMUNICATION solution for wireless cellular

87

Cable Jacket Material

DesignationPolyolefine

Flame RetardantPolyvinylChloride

PolyethylenePolyurethane

Flame RetardantPolyamide

Abbreviation LSZH PVC PE TPU/PR PA(Nylon)

Combustion Properties

Halogen Free Yes No Yes Yes Yes

Flame Retardant Yes Yes No Yes No

Smoke Emission Low Strong Medium Medium Strong

Corrosive Fumes Low High No Low No

Mechanical Properties

Abrasion Resistance Low Medium Good Good Good

Flexibility High High Low High Low

Hardness Medium Soft Hard Soft Hard

Resistance Against

Oil/Fuel Good Good Good Satisfactory Good

Water Good Good Very Good Good Satisfactory

Weathering Good Good Very Good Good Good

• Information given in the table is based on plastic materials used for cable jackets. Properties and resistance for cables can not bederived from it.

• The resistance against oil/fuel is meant as decision guidance to the best of our today’s knowledge. It is based on typical values. The resistance of cables has to be verified due to the wide variety of oils and fuels.

• The resistance against weathering is same as the UV resistance and it highly depends on the color of jacket material used.

Test Procedure

Tensile Performance

• Standard: IEC 60794-1-2 E1• Object: Detect the attenuation behavior and/or fiber elongation strain as a function of the

load on the cable when occur during installation. Meanwhile the tension applied shall be within the maximum allowable tensile force.

• Requirement: the result data shall not exceed the values given in the relevant detail specification.

Abrasion

• Standard: IEC 60794-1-2 E2• Object: Determines the ability of the cable sheath to resist abrasion and the ability of

cable markings to resist abrasion.• Requirement: No perforation of the sheath and optical continuity shall be maintained

andthe marking shall be legible after performing the number of cycles specified in the detail specification.

Page 89: FIBER OPTICS AND DATA COMMUNICATIONrosenberger.co.kr/data/(카탈로그) FTTA-Fiber to the... · 2016-12-31 · FIBER OPTICS AND DATA COMMUNICATION solution for wireless cellular

88

Crush Resistance

• Standard: IEC 60794-1-2 E3• Object: Determines the ability of the cable to withstand crushing and detect the influence

of the constant load on the attenuation.• Requirement: the result data shall not exceed the values given in the relevant detail

specification and no typical failure modes including the degradation transmission or physical damage to the cable.

Impact Performance• Standard: IEC 60794-1-2 E4• Object: Determines the ability of the cable to withstand repeated impacts on the

attenuation and it simulates the dropping heavy objects such as stones and tools when on operation.

• Requirement: the result data shall not exceed the values given in the relevant detail specification and no typical failure modes including the degradation transmission or physical damage to the cable.

Repeated Bending• Standard: IEC 60794-1-2 E6• Object: Determines the ability of the cable to withstand repeated bending under tension

load and the two extreme positions make an angle of 90 degree on both sides of the vertical.

• Requirement: the result data shall not exceed the values given in the relevant detail specification and no typical failure modes including the degradation transmission or physical damage to the cable

Torsion• Standard: IEC 60794-1-2 E7• Object: Detects the ability of the cable to withstand the mechanical twisting and measures

any variation in the optical transmission when the cable is subjected to torsional forces external to the cable jacket and evaluates the possibility of physical damage.

• Requirement: the result data shall not exceed the values given in the relevant detail specification and no typical failure modes including loss of optical continuity or physical damage to the jacket or components

Flexing Performance• Standard: IEC 60794-1-2 E8• Object: Determines the ability of the cable to withstand repeated flexing, for example

elevator cable and measures any variation in the optical transmission when the cable is on repeated flexing state and evaluates the possibility of physical damage.

• Requirement: the result data shall not exceed the values given in the relevant detail specification and no typical failure modes including loss of optical continuity or physical damage to the jacket.

Temperature Cycling• Standard: IEC 60794-1-2 F1• Object: Determines the stability behavior of the attenuation of optical cables when the

temperature changes. It is generally the result of buckling or tensioning of fibers resulting from differences between their thermal expansion coefficient and the coefficients of strength and jacket members.

• Requirement: the result data shall not exceed the values given in the relevant detail specification and no typical failure modes including loss of optical continuity or physical damage to the jacket

Water Penetration

Page 90: FIBER OPTICS AND DATA COMMUNICATIONrosenberger.co.kr/data/(카탈로그) FTTA-Fiber to the... · 2016-12-31 · FIBER OPTICS AND DATA COMMUNICATION solution for wireless cellular

89

• Standard: IEC 60794-1-2 F5A/F5B• Object: Applies to the continuously water-blocked cables and determines the ability of

a cable to block water migration along a specified length and evaluates the resistance ability to the water and humidity.

• Requirement: No water shall be detected at the unsealed end of the sample cable and thetime and dispersal of the water within the sample are the determining test criteria.

Vertical Flame Propagation for a Single Cable

• Standard: IEC 60332-1• Object: Evaluates the flame propagation on the single cable, which is for communication,

installed on the surface of walls inside buildings under the fire condition.• Requirement: 60mm length sample cable is mounted vertically and the flame must

extinguish itself in relevant time and the fire damage must not reach the upper end of the sample cable.

Vertical Flame Propagation for the Bundle Cables

• Standard: IEC 60332-3• Object: Evaluates the flame propagation on the bundle cables, which are depend on the

volume of flammable material, fixed on a 3.5m long ladder and flame is applied at the base during 20 minutes.

• Requirement: the height of fire damage must not exceed 2.5m and cables have an improved characteristics regarding fire propagation when it pass the test.

Smoke Emission• Standard: IEC 61034• Object: The measurement of smoke density is an important aspect in the evaluation

of the burning performance of cables as it is related to the evacuation of persons and accessibility for fire-fighting. In a defined test environment the cable is exposed to an open fire of burning alcohol and it allows a statement of the expected line-of-sight obstruction in case of fire.

• Requirement: the result data shall not exceed the values given in the relevant detail specification.

Corrosive Fire Gases and Free of Halogen• Standard: IEC 60754-1/60754-2• Object: Determines the volume of the corrosive fire gas and the halogen gas emission,

which are washed out when the flammable materials are combusted at over 900 degree.The corrosiveness is determined by means of ph-values and electric conductivity. Halogen materials can release a considerable quantity of corrosive gases, which can cause consequential damage to the surrounding area as well as respiratory problems.

• Requirement: the result data shall not exceed the values given in the relevant detail specification.

Page 91: FIBER OPTICS AND DATA COMMUNICATIONrosenberger.co.kr/data/(카탈로그) FTTA-Fiber to the... · 2016-12-31 · FIBER OPTICS AND DATA COMMUNICATION solution for wireless cellular

90

Buffered Fiber

DescriptionBuffered fiber is made of bare fiber, fiber coating and buffer material. It is usually used for fiber optic link interconnection by terminating with fiber optic connectors.

Feature and Benefit• Tight buffer, semi-tight buffer or loose buffer• 0.6mm or 0.9mm diameter• Buffer material options PVC, Hytrel, LSZH, Nylon• All fiber type options• Low attenuation

SpecificationProfile/Outline

Core

Cladding

Coating

Buffer

Construction/Material

Fiber Type 250μm or 500μm optical fiber

Fiber Color Nature or other standard color

Buffer Material PVC or LSZH or other specified

Buffer Color White or other color specified available

Temperature Range

Transport and Storage Temperature -30℃ ~ +65℃

Installation Temperature -20℃~ +50℃

Operation Temperature -30℃ ~ +65℃

Page 92: FIBER OPTICS AND DATA COMMUNICATIONrosenberger.co.kr/data/(카탈로그) FTTA-Fiber to the... · 2016-12-31 · FIBER OPTICS AND DATA COMMUNICATION solution for wireless cellular

91

Mechanical Properties

FiberCount

NominalBuffer Diameter

(mm)

NominalCable Weight

(Kg/Km)

Tensile Strength Long-term/Short-term

(N)

Crush Resistance Long-term/Short-term

(N/10cm)

Strip LengthIn One Piece

Min.(mm)

Min. Bend Radius Static/Dynamic

(mm)

1 0.6/0.9 0.9 3/6 100/500 30 30/50

Cable Transmission Performance

Fiber Symbol G652D/G657A1/A2/B2/B3 G655C/D/E OM1 OM2/OM2+ OM3/OM4

Fiber Type B1.3/B6a.1/2 B6b.2/3 B4 A1b A1a/A1a.1 A1a.2/A1a.3Wavelength(nm)

1310 1383 1550 1550 1625 850 1300 850 1300 850 1300

Attenuation(dB/Km)

≤0.36 ≤0.36 ≤0.22 ≤0.22 ≤0.25 ≤3.2 ≤1.0 ≤2.7 ≤1.0 ≤2.7 ≤1.0

Ordering Information

RB□□ - □□ □□ - □ □ - □□□□□

Product Type

Jacket ColorYL = Yellow T = Tight Buffer

Jacket Material02 = LSZH04 = PVC<OFNR>

Fiber SymbolG652D = Fiber G.652D

S = Semi-Tight Buffer

Fiber Buffer Type

1

2

3

5

6

1 2 3 4 5 6

OR = Orange

05 = PVC<OFNP>

BL = BlueAQ = AquaGR = Green

6 = 600 μm

Fiber Buffer Diameter4

9 = 900 μm

OM4 = Fiber OM4OM3 = Fiber OM3

RB01 = Tight BufferRB02 = Semi-Tight BufferRB03 = Loose Buffer

L = Loose Buffer

09 = Nylon

Page 93: FIBER OPTICS AND DATA COMMUNICATIONrosenberger.co.kr/data/(카탈로그) FTTA-Fiber to the... · 2016-12-31 · FIBER OPTICS AND DATA COMMUNICATION solution for wireless cellular

92

Construction/Material

Buffer Tight buffer or semi-tight buffer

Buffer Color White or other color specified

Strength Member Aramid yarn (Kevlar)

Cable Jacket PVC or LSZH or other specified

Color of Jacket

Yellow for Singlemode

Orange for Multimode

Aqua for OM3

Other color specified available

Temperature Range

Transport and Storage Temperature -20℃ ~ +70℃

Installation Temperature -5℃ ~ +50℃

Operation Temperature -20℃ ~ +70℃

Simplex Fiber Optic Cable

DescriptionSimplex fiber optic cable is made of buffered fiber, strength member and jacket material. It is usually used for fiber optic link interconnection and patching by terminating with fiber optic connectors.

Feature and Benefit• 1.6-3.0mm diameter• Aramid yarn high strength material• All fiber type options• Low attenuation• Jacket color options• OFNR per UL-1666 and OFNP per UL-910 • LSZH per IEC 60332-1/3, IEC 60754-2 and IEC 61034-2

SpecificationProfile/Outline

Core

Cladding

Coating

Buffer

Aramid Yarns Strength Member

Jacket

Page 94: FIBER OPTICS AND DATA COMMUNICATIONrosenberger.co.kr/data/(카탈로그) FTTA-Fiber to the... · 2016-12-31 · FIBER OPTICS AND DATA COMMUNICATION solution for wireless cellular

93

Mechanical Properties

FiberCount

NominalCable Diameter

(mm)

NominalBuffer Diameter

(Kg/Km)

NominalCable Weight

(Kg/Km)

Tensile StrengthLong-term/Short-term

(N)

Crush ResistanceLong-term/Short-term

(N/10cm)

Min. Bend Radius Static/Dynamic

(mm)1 1.6 0.6 2.9 60/120 100/500 30/50

1 1.8 0.9 3.7 60/120 100/500 30/50

1 2.0 0.9 5.0 60/120 100/500 30/50

1 2.4 0.9 5.7 80/150 100/500 30/50

1 2.8 0.9 7.9 80/150 100/500 30/50

1 3.0 0.9 8.1 80/150 100/500 30/50

Cable Transmission Performance

Fiber Symbol G652D/G657A1/A2/B2/B3 G655C/D/E OM1 OM2/OM2+ OM3/OM4

Fiber Type B1.3/B6a.1/2 B6b.2/3 B4 A1b A1a/A1a.1 A1a.2/A1a.3Wavelength(nm)

1310 1383 1550 1550 1625 850 1300 850 1300 850 1300

Attenuation(dB/Km)

≤0.45 ≤0.45 ≤0.35 ≤0.35 ≤0.40 ≤3.5 ≤1.5 ≤3.2 ≤1.2 ≤3.0 ≤1.0

Ordering Information

RI07- □□ □□ □□ - □□ - 0 0 1 - □□□□□

Product TypeRI07 = Product No.

Jacket ColorYL = Yellow T = Tight Buffer

Jacket Material02 = LSZH04 = PVC<OFNR>

Cable Diameter16 = 1.6mm18 = 1.8mm

Fiber Count001 = 1 Core

Fiber SymbolG652D = Fiber G.652D

S = Semi-Tight Buffer

Fiber Buffer Type

1

2

3

4

6

7

8

1 2 3 4 5 6 7 8

OR = Orange

05 = PVC<OFNP>

20 = 2.0mm

24 = 2.4mm28 = 2.8mm30 = 3.0mm

BL = BlueAQ = AquaGR = Green

6 = 600 um

Fiber Buffer Diameter5

9 = 900 um

OM4 = Fiber OM4OM3 = Fiber OM3

L = Loose Buffer

Page 95: FIBER OPTICS AND DATA COMMUNICATIONrosenberger.co.kr/data/(카탈로그) FTTA-Fiber to the... · 2016-12-31 · FIBER OPTICS AND DATA COMMUNICATION solution for wireless cellular

94

Construction/Material

Buffer Tight buffer or semi-tight buffer

Buffer ColorWhite/Blue or Blue/OrangeOther color specified available

Strength Member Aramid yarn (Kevlar)

Cable Jacket PVC or LSZH or other specified

Color of Jacket

Yellow for Singlemode

Orange for Multimode

Aqua for OM3

Other color specified available

Temperature Range

Transport and Storage Temperature -20℃ ~ +70℃

Installation Temperature -5℃ ~ +50℃

Operation Temperature -20℃ ~ +70℃

Duplex Fiber Optic Cable

DescriptionDuplex fiber optic cable is made of two buffered fibers, strength member and jacket material and in a figure of eight. It is usually used for fiber optic link interconnection and cross-connect patching by terminating with fiber optic connectors.

Feature and Benefit• Single cable diameter 1.6-3.0mm• Aramid yarn high strength material• All fiber type options• Low attenuation performance• Jacket color options• OFNR per UL-1666 and OFNP per UL-910 • LSZH per IEC 60332-1/3, IEC 60754-2 and IEC 61034-2

SpecificationProfile/Outline

Core

Cladding

Coating

Buffer

Aramid Yarns Strength Member

Jacket

Page 96: FIBER OPTICS AND DATA COMMUNICATIONrosenberger.co.kr/data/(카탈로그) FTTA-Fiber to the... · 2016-12-31 · FIBER OPTICS AND DATA COMMUNICATION solution for wireless cellular

95

Mechanical Properties

FiberCount

NominalCable Diameter

(mm)

NominalBuffer Diameter

(mm)

NominalCable Weight

(Kg/Km)

Tensile StrengthLong-term/Short-term

(N)

Crush ResistanceLong-term/Short-term

(N/10cm)

Min. Bend Radius Static/Dynamic

(mm)2 1.6*3.3 0.6 5.8 60/120 100/500 30/60

2 1.8*3.7 0.9 7.4 60/120 100/500 30/60

2 2.0*4.1 0.9 10.0 60/120 100/500 30/60

2 2.4*4.9 0.9 11.4 80/150 100/500 30/60

2 2.8*5.7 0.9 15.8 80/150 100/500 30/60

2 3.0*6.1 0.9 16.2 80/150 100/500 30/60

Cable Transmission Performance

Fiber Symbol G652D/G657A1/A2/B2/B3 G655C/D/E OM1 OM2/OM2+ OM3/OM4

Fiber Type B1.3/B6a.1/2 B6b.2/3 B4 A1b A1a/A1a.1 A1a.2/A1a.3Wavelength(nm)

1310 1383 1550 1550 1625 850 1300 850 1300 850 1300

Attenuation(dB/Km)

≤0.45 ≤0.45 ≤0.35 ≤0.35 ≤0.40 ≤3.5 ≤1.5 ≤3.2 ≤1.2 ≤3.0 ≤1.0

Ordering Information

RI08- □□ □□ □□ - □□ - 0 0 2 - □□□□□

Product TypeRI08 = Product No.

Jacket ColorYL = Yellow T = Tight Buffer

Jacket Material02 = LSZH04 = PVC<OFNR>

Cable Diameter16 = 1.6mm18 = 1.8mm

Fiber Count002 = 2 Cores

Fiber SymbolG652D = Fiber G.652D

S = Semi-Tight Buffer

Fiber Buffer Type

1

2

3

4

6

7

8

1 2 3 4 5 6 7 8

OR = Orange

05 = PVC<OFNP>

20 = 2.0mm

24 = 2.4mm28 = 2.8mm30 = 3.0mm

BL = BlueAQ = AquaGR = Green

6 = 600 μm

Fiber Buffer Diameter5

9 = 900 μm

OM4 = Fiber OM4OM3 = Fiber OM3

L = Loose Buffer

Page 97: FIBER OPTICS AND DATA COMMUNICATIONrosenberger.co.kr/data/(카탈로그) FTTA-Fiber to the... · 2016-12-31 · FIBER OPTICS AND DATA COMMUNICATION solution for wireless cellular

96

Construction/Material

Buffer Tight buffer or semi-tight buffer

Buffer Color Per TIA 598-B

Strength Member Aramid yarn (Kevlar)

Ripcord Easily ripping the cable jacket

Cable Jacket PVC or LSZH or other specified

Color of Jacket

Yellow for SinglemodeOrange for MultimodeAqua for OM3Other color specified available

Temperature Range

Transport and Storage Temperature -20℃ ~ +70℃

Installation Temperature -5℃ ~ +50℃

Operation Temperature -20℃ ~ +70℃

Distribution Fiber Optic Cable

DescriptionDistribution fiber optic cable is made of multiple buffered fibers, strength member and jacket material as well as a ripcord as option. It is usually used for fiber optic link interconnection, main trunk and building riser distribution with or without fiber optic connector terminated.

Feature and Benefit• Up to 24 fibers or more on request• Aramid yarn high strength material• All fiber type options• Low attenuation performance• Jacket color options• OFNR per UL-1666 and OFNP per UL-910 • LSZH per IEC 60332-1/3, IEC 60754-2 and IEC 61034-2

SpecificationProfile/Outline

Fiber

Buffer

Aramid Yarns Strength Member

Ripcord (option)

Jacket

Page 98: FIBER OPTICS AND DATA COMMUNICATIONrosenberger.co.kr/data/(카탈로그) FTTA-Fiber to the... · 2016-12-31 · FIBER OPTICS AND DATA COMMUNICATION solution for wireless cellular

97

Mechanical Properties

Fiber Count

Subunit Count

Nominal Cable Diameter

(mm)

Nominal Cable Weight(LSZH/PVC)

(Kg/Km)

Tensile Strength Long-term/Short-term

(N)

Crush Resistance Long-term/Short-term

(N/10cm)

Min. Bend Radius Static/Dynamic

(mm)2 1 4.0 14/13 130/440 200/1000 40/80

4 1 4.8 18/16 130/440 200/1000 48/96

6 1 5.1 23/20 130/440 200/1000 51/102

8 1 5.6 31/27 130/440 200/1000 55/110

10 1 5.8 34/29 130/440 200/1000 58/116

12 1 6.2 36/32 130/440 200/1000 62/124

18 1 8.1 57/53 130/440 200/1000 81/162

24 1 8.1 57/53 130/440 200/1000 81/162

Cable Transmission Performance

Fiber Symbol G652D/G657A1/A2/B2/B3 G655C/D/E OM1 OM2/OM2+ OM3/OM4

Fiber Type B1.3/B6a.1/2 B6b.2/3 B4 A1b A1a/A1a.1 A1a.2/A1a.3Wavelength(nm)

1310 1383 1550 1550 1625 850 1300 850 1300 850 1300

Attenuation(dB/Km)

≤0.45 ≤0.45 ≤0.35 ≤0.35 ≤0.40 ≤3.5 ≤1.5 ≤3.2 ≤1.2 ≤3.0 ≤1.0

Ordering Information

RI12- □□ □□ - □□ - □□□ - □□□□□

Product TypeRI12 = Product code

Jacket ColorYL = Yellow T = Tight Buffer

Jacket Material02 = LSZH04 = PVC<OFNR>

Fiber Count004 = 4 Cores

Fiber SymbolG652D = Fiber G.652D

S = Semi-Tight Buffer

Fiber Buffer Type

1

2

3

5

6

7

1 2 3 4 5 6 7

OR = Orange

05 = PVC<OFNP>

BL = BlueAQ = AquaGR = Green

6 = 600 μm

Fiber Buffer Diameter4

9 = 900 μm

OM4 = Fiber OM4OM3 = Fiber OM3

L = Loose Buffer

024 = 24 Cores...

Page 99: FIBER OPTICS AND DATA COMMUNICATIONrosenberger.co.kr/data/(카탈로그) FTTA-Fiber to the... · 2016-12-31 · FIBER OPTICS AND DATA COMMUNICATION solution for wireless cellular

98

Breakout fiber Optic Cable

DescriptionBreakout fiber optic cable is made of multiple 2.0mm simplex cables, dielectric central strength member, wrap tape, jacket material and a ripcord. It is usually used for fiber optic link interconnection, main trunk and building riser distribution by terminating with fiber optic connectors.

Feature and Benefit

SpecificationProfile/Outline

Construction/Material

Buffer 900μm tight buffer or semi-tight buffer

Buffer Color White or other color specified

Strength Member Aramid yarn (Kevlar)

Subunit Diameter 2.0mm

Subunit Jacket PVC or LSZH jacket

Central MemberFRP as the dielectric member for central strength element with no bonding

Ripcord Easily ripping the cable jacket

Cable Jacket PVC or LSZH or other specified

Color of Jacket and Subunit Jacket

Yellow for SinglemodeOrange for MultimodeAqua for OM3Other color specified available

Temperature Range

Transport and Storage Temperature -20℃ ~ +70℃

Installation Temperature -5℃ ~ +50℃

Operation Temperature -20℃ ~ +70℃

Fiber

900um Buffer

Aramid Yarns Strength Member

2.0mm Fiber Subunit

FRP

Wrap Tape (option)

Ripcord (option)

Jacket

• Up to 24 fibers or more on request• Aramid yarn high strength material for subunits• All fiber type options• Low attenuation performance

• Jacket color options• OFNR per UL-1666 and OFNP per UL-910 • LSZH per IEC 60332-1/3, IEC 60754-2 and IEC 61034-2

Page 100: FIBER OPTICS AND DATA COMMUNICATIONrosenberger.co.kr/data/(카탈로그) FTTA-Fiber to the... · 2016-12-31 · FIBER OPTICS AND DATA COMMUNICATION solution for wireless cellular

99

Mechanical Properties

Fiber Count

Nominal Cable Diameter

(mm)

Nominal Cable Weight(LSZH/PVC)

(Kg/Km)

Tensile Strength Long-term/Short-term

(N)

Crush Resistance Long-term/Short-term

(N/10cm)

Min. Bend Radius Static/Dynamic

(mm)2 7.4 56/50 250/500 300/1000 74/148

4 7.4 56/50 250/500 300/1000 74/148

6 8.4 74/66 250/500 300/1000 84/168

8 9.8 101/91 500/1000 300/1000 98/196

12 12.0 134/121 500/1000 300/1000 120/240

16 12.4 155/140 500/1000 300/1000 124/248

24 14.4 201/181 500/1000 300/1000 144/288

Cable Transmission Performance

Fiber Symbol G652D/G657A1/A2/B2/B3 G655C/D/E OM1 OM2/OM2+ OM3/OM4Fiber Type B1.3/B6a.1/2 B6b.2/3 B4 A1b A1a/A1a.1 A1a.2/A1a.3Wavelength(nm)

1310 1383 1550 1550 1625 850 1300 850 1300 850 1300

Attenuation(dB/Km)

≤0.45 ≤0.45 ≤0.35 ≤0.35 ≤0.40 ≤3.5 ≤1.5 ≤3.2 ≤1.2 ≤3.0 ≤1.0

Ordering Information

RI14- □□ □□ □□ - □□ - □□□ - □□□□□

Product TypeRI14 = Product No.

Jacket ColorYL = Yellow T = Tight Buffer

Jacket Material02 = LSZH04 = PVC<OFNR>

Cable Diameter

Fiber Count002 = 2 Cores

Fiber SymbolG652D = Fiber G.652D

S = Semi-Tight Buffer

Fiber Buffer Type

1

2

3

4

6

7

8

1 2 3 4 5 6 7 8

OR = Orange

05 = PVC<OFNP>

20 = 2.0mm

BL = BlueAQ = AquaGR = Green

6 = 600 μm

Fiber Buffer Diameter5

9 = 900 μm

OM4 = Fiber OM4OM3 = Fiber OM3

L = Loose Buffer

024 = 24 Cores...

Page 101: FIBER OPTICS AND DATA COMMUNICATIONrosenberger.co.kr/data/(카탈로그) FTTA-Fiber to the... · 2016-12-31 · FIBER OPTICS AND DATA COMMUNICATION solution for wireless cellular

100

Construction/MaterialBuffer Type 600μm/900μm tight bufferBuffer Color 2 Cores: Blue/Red 4 Cores: Blue/Red/Green/YellowStrength Member Aramid yarn (Kevlar) or Glass yarnCable Jacket LSZH, PVC or other specifiedColor of Jacket Black (UV resistant)Temperature RangeTransport and Storage -40℃ ~ +85℃ (+95℃)Installation -20℃ ~ +60℃Operation -40℃ ~ +85℃

Mechanical Properties

FiberCount

NominalCable Diameter

(mm)

NominalCable Weight

(Kg/Km)

Tensile Strength Long-term/Short-term

(N)

Crush Resistance Long-term/Short-term

(N/10cm)

Min. Bend Radius Static/Dynamic

(mm)2 4.8 18 300/450 1000/2200 48/964 5.2 18 300/450 1000/2200 48/96

Cable Transmission Performance

Fiber Symbol G652D/G657A1/A2/B2/B3 G655C/D/E OM1 OM2/OM2+ OM3/OM4Fiber Type B1.3/B6a.1/2 B6b.2/3 B4 A1b A1a/A1a.1 A1a.2/A1a.3Wavelength(nm) 1310 1383 1550 1550 1625 850 1300 850 1300 850 1300Attenuation(dB/Km) ≤0.45 ≤0.45 ≤0.35 ≤0.35 ≤0.40 ≤3.5 ≤1.5 ≤3.2 ≤1.2 ≤3.0 ≤1.0

Distribution Fiber Optic Cable for FTTA

DescriptionThis specialized distribution fiber optic cable is designed for harsh environment application such as high performance fiber-to-the-antenna (FTTA) cabling for current 3G and 4G/LTE network. The cable is made of multiple specialized buffered fibers, water-blocking strength member and high quality jacket material to provide outstanding optical, mechanical and environmental performance.

Feature and Benefit

SpecificationProfile/Outline

Fiber

Tight Buffer

Strength Member

Jacket

• Up to 4 fibers or more on request• All fiber type options• Low attenuation performance• Compact cable size

• Water proof design• Support rigorous temperature range• LSZH-rated per IEC 60332-1/3, IEC 60754-2 and IEC 61034-2• OFNR (UL-1666) approval option

Page 102: FIBER OPTICS AND DATA COMMUNICATIONrosenberger.co.kr/data/(카탈로그) FTTA-Fiber to the... · 2016-12-31 · FIBER OPTICS AND DATA COMMUNICATION solution for wireless cellular

101

Construction/MaterialBuffer Type 600μm/900μm tight bufferBuffer Color Singlemode: Red/Blue Multimode: Orange/WhiteArmored Spiral stainless tubeStrength Member Aramid yarn (Kevlar) or Glass yarnCable Jacket LSZH, PVC or other specifiedColor of Jacket Black (UV resistant)Temperature RangeTransport and Storage Temperature -40℃ ~ +85℃Installation Temperature -20℃ ~ +65℃Operation Temperature -40℃ ~ +85℃

Mechanical Properties

FiberCount

NominalCable Diameter

(mm)

NominalCable Weight

(Kg/Km)

Tensile Strength Long-term/Short-term

(N)

Crush Resistance Long-term/Short-term

(N/10cm)

Min. Bend Radius Static/Dynamic

(mm)2 4.8 38.5 300/450 1000/3000 48/96

Cable Transmission Performance

Fiber Symbol G652D/G657A1/A2/B2/B3 G655C/D/E OM1 OM2/OM2+ OM3/OM4Fiber Type B1.3/B6a.1/2 B6b.2/3 B4 A1b A1a/A1a.1 A1a.2/A1a.3Wavelength(nm) 1310 1383 1550 1550 1625 850 1300 850 1300 850 1300Attenuation(dB/Km) ≤0.45 ≤0.45 ≤0.35 ≤0.35 ≤0.40 ≤3.5 ≤1.5 ≤3.2 ≤1.2 ≤3.0 ≤1.0

Armored Fiber Optic Cable for FTTA

DescriptionThis type of armored fiber optic cable is designed for harsh environment application such as high performance fiber-to-the-antenna (FTTA) cabling for current 3G and 4G/LTE network. The cable is made of multiple specialized buffered fibers, spiral stainless steel amore tube, water-blocking strength member and high quality jacket material to provide outstanding optical, mechanical and environmental performance as well as rodent protection capability.

Feature and Benefit

SpecificationProfile/Outline

Fiber

Tight Buffer

Spiral Amored Tube

Strength Member

Jacket

• Up to 4 fibers or more on request• All fiber type options• Low attenuation performance• Compact cable size• Water proof design

• Support rigorous temperature range• Rodent protection and monkey bite• LSZH-rated per IEC 60332-1/3, IEC 60754-2 and IEC 61034-2• OFNR (UL-1666) approval option

Page 103: FIBER OPTICS AND DATA COMMUNICATIONrosenberger.co.kr/data/(카탈로그) FTTA-Fiber to the... · 2016-12-31 · FIBER OPTICS AND DATA COMMUNICATION solution for wireless cellular

102

Construction/MaterialBuffer Type 600μm/900μm tight bufferBuffer Color White or other specifiedSub-unit Jacket LSZHSub-unit Jacket Color (2-core) Singlemode: Yellow/Blue Multimode: Orange/GreySub-unit Jacket Diameter 2.0mmStrength Member Aramid yarn (Kevlar)Cable Jacket LSZH Color of Jacket Black (UV resistant)Temperature RangeTransport and Storage Temperature -40℃ ~ +80℃Installation Temperature -20℃ ~ +60℃Operation Temperature -40℃ ~ +80℃

Mechanical Properties

FiberCount

NominalCable Diameter

(mm)

FiberStructure

(mm)

NominalCable Weight

(Kg/Km)

Tensile Strength Long-term/Short-term

(N)

Crush Resistance Long-term/Short-term

(N/10cm)

Min. Bend Radius Static/Dynamic

(mm)2 7.0 0.6/0.9 38 200/400 1000/2200 70/140

Cable Transmission Performance

Fiber Symbol G652D/G657A1/A2/B2/B3 G655C/D/E OM1 OM2/OM2+ OM3/OM4

Fiber Type B1.3/B6a.1/2 B6b.2/3 B4 A1b A1a/A1a.1 A1a.2/A1a.3

Wavelength(nm) 1310 1383 1550 1550 1625 850 1300 850 1300 850 1300

Attenuation(dB/Km) ≤0.45 ≤0.45 ≤0.35 ≤0.35 ≤0.40 ≤3.5 ≤1.5 ≤3.2 ≤1.2 ≤3.0 ≤1.0

Breakout Fiber Optic Cable for FTTA

DescriptionThis type of specialized breakout fiber optic cable is designed for harsh environment application such as high performance fiber-to-the-antenna (FTTA) cabling for current 3G and 4G/LTE network. The cable is made of multiple 2.0mm subunits, water-blocking strength member and high quality jacket material to provide outstanding optical, mechanical and environmental performance.

Feature and Benefit

SpecificationProfile/Outline

Fiber

Tight Buffer

Aramid Yarns Strength Member

Subunit Cable Jacket

Filler Jacket

Jacket

• Up to 4 fibers or more on request• All fiber type options• Low attenuation performance• Water proof design

• Support rigorous temperature range• LSZH-rated per IEC 60332-1/3, IEC 60754-2 and IEC 61034-2• OFNR (UL-1666) approval option

Page 104: FIBER OPTICS AND DATA COMMUNICATIONrosenberger.co.kr/data/(카탈로그) FTTA-Fiber to the... · 2016-12-31 · FIBER OPTICS AND DATA COMMUNICATION solution for wireless cellular

103

Page 105: FIBER OPTICS AND DATA COMMUNICATIONrosenberger.co.kr/data/(카탈로그) FTTA-Fiber to the... · 2016-12-31 · FIBER OPTICS AND DATA COMMUNICATION solution for wireless cellular

www.rosenberger.comwww.rosenbergerap.com

Rosenberger Hochfrequenzetechnik GmbH & Co. KGP. O. BOX 1260 D-84526 TittmoningTel: +49-86 84-18-0 I E-mail: [email protected]: +49-86 84-18-499 I Web: www.rosenberger.com

No.3, Anxiang Street, Block B, Tianzhu Airport Industrial Zone, Beijing, China 101300Tel : (+86 10) 80481995 I E-mail: [email protected] : (+86 10) 80497052 I Web: www.rosenbergerap.com

Rosenberger (Shanghai) Technology Co., Ltd.B7, No. 509, Renqing Road, East Zone of Zhangjiang High-Tech Park, Shanghai, China 201201Tel : (+86 21) 58995997 I E-mail: [email protected] : (+86 21) 58995994 I Web: www.rosenbergerap.com

Rosenberger Technology (Kunshan) Co., Ltd.No.6, Shenan Road, Dianshanhu Town, Kunshan, Jiangsu, China 215345Tel : (+86 512) 86896789 I E-mail: [email protected] : (+86 512) 86890666 I Web: www.rosenbergerap.com

48