カタログ ASLINKPOKAYOKE 英語 PDF · POKA-YOKE is a global common word The POKAYOKE system...

36
ASLINKPOKAYOKE series catalog New Sensor Network Technology AnyWire for wiring saving ASLINKPOKAYOKE series

Transcript of カタログ ASLINKPOKAYOKE 英語 PDF · POKA-YOKE is a global common word The POKAYOKE system...

Page 1: カタログ ASLINKPOKAYOKE 英語 PDF · POKA-YOKE is a global common word The POKAYOKE system comprising the AnyWire POKAYOKE terminal provides a solution to this problem simply

ASLINKPOKAYOKE series catalog

New Sensor Network TechnologyAnyWire for wiring saving

ASLINKPOKAYOKE series

Page 2: カタログ ASLINKPOKAYOKE 英語 PDF · POKA-YOKE is a global common word The POKAYOKE system comprising the AnyWire POKAYOKE terminal provides a solution to this problem simply

ASLINKPOKAYOKE series

ASLINKPOKAYOKE series01

Index

ASLINKPOKAYOKE

series catalog

Table of Contents

・・・・・

・・・・

・・・・・・・・

・・・・・・・・・・

・・・・・・・・・・・・・・

・・・・・・・・・・・・・・

・・・・・・・・・・・・

・・・・

09

10

11

13

25

27

29

31

POKAYOKE terminal selection procedure

Basic transmission specification of system

・・・・・・

・・・・・

03

05

・Case example of application

◇System Overview

・・・・ 02・What is the POKAYOKE terminal?

・Reason to select AnyWire (1 to 3)

・System configuration and selection procedure

◇Product variation

・Product list (Matrix diagram)

・Product details page

・Accessories

・Master units

・Address setting

・Outline Dimensional Drawings (3-view drawing)

Page 3: カタログ ASLINKPOKAYOKE 英語 PDF · POKA-YOKE is a global common word The POKAYOKE system comprising the AnyWire POKAYOKE terminal provides a solution to this problem simply

ASLINKPOKAYOKE series 02

After

ADDRESS

ON

ADDRESS

ON

ADDRESS

ON

ADDRESS

ON

ADDRESS

ON

ADDRESS

ON

ADDRESS

ON

ADDRESS

ON

ADDRESS

ON

ADDRESS

ON

ADDRESS

ON

ADDRESS

ON

POKAYOKE Terminal System

ADDRESS

ON

ADDRESS

ON

ADDRESS

ON

ADDRESS

ON

ADDRESS

ON

ADDRESS

ON

POKAYOKE Terminal System

After

Conventional System

Before

Before

Conventional System

When you install the POKAYOKE system,

Before & After

“Picking” work to select parts from inventory according to instruction is carried out at

production sites where parts are assembled. Increase in types of parts also increases

risks to incorrectly pick parts of similar shape and approximate part name, which is a

major problem at production sites.

“Picking” on assembly/production sites

Control of human errors in picking work is an essential element for enhancement and

improvement in production ef�ciency and product quality. Systems and devices to

prevent such human-induced careless mistakes (poka) are called “POKA-YOKE,” and

currently some overseas production sites have adopted the Japanese-derived term

“POKA-YOKE,” to indicate the importance of this manufacturing challenge.

“POKA-YOKE” is a global common word

The “POKAYOKE system” comprising the AnyWire POKAYOKE terminal provides a solution to this problem simply and at low cost.

There is no need to look for parts with a list in one hand, and no errors occur in parts and quantity.

In addition, these POKAYOKE terminals into which AnyWire’s unique Sho-Haisen technology is integrated offer many advantages

such as freedom of installation, easy wiring work, �exibility in change and remodeling, and dif�culties in introduction can be

lowered.

◇ As the location of parts is informed by LED lamps, parts can be clearly identified even in a dark warehouse.

◇ As only the door for location from which parts should be taken out opens, retrieval errors never occur.

◇ As the quantity of parts is clearly instructed by 7-segment indication, errors in quantity never occur.

“POKAYOKE” terminal of AnyWire

At an Automotive Assembly Site!At an Automotive Assembly Site!

At an Electronics Equipment Assembly Site!At an Electronics Equipment Assembly Site!

Time and effort required to read a list and instructionsDo not know as to where actual parts areOne handed operationTime required to assembleIncorrect parts assembly occurs

No need to read a list or instructionsKnow where actual parts are at onceCan operate with both handsAssembly time reducedQuality improved with correct parts assembly

ASLINKPOKAYOKE series

What is the POKAYOKE terminal?

Concept

Page 4: カタログ ASLINKPOKAYOKE 英語 PDF · POKA-YOKE is a global common word The POKAYOKE system comprising the AnyWire POKAYOKE terminal provides a solution to this problem simply

<Take-out>Application 1

POKAYOKE terminal for “Take-out” process

The f i rs t appl icat ion is “take-out.”

“High-mix and low-volume production” is typically the case at current production sites, and “take-out” is inevitably a major point in increasing production effi-ciency and stabilizing prod-uct quality.

A d o p t i o n o f t h e P O -KAYOKE terminal can sig-n i f i cant ly reduce work man-hours, eliminate errors in take-out of parts and also reduce worker stress.

<Throw-in>Application 2

POKAYOKE terminal for “Throw-in” process

ASLINKPOKAYOKE series03

ASLINKPOKAYOKE series

Applications

The second application is “Throw-in.”

“Throw-in” always exists at product ion s i tes where “Take-out” exists.The POKAYOKE terminal is also used to prevent errors in “Throw-in” of parts.

A d o p t i o n o f t h e P O -K A Y O K E t e r m i n a l c a n secure conf i rmat ion of throw-in of parts. It is rec-ommended to introduce the POKAYOKE terminal for “throw-in” in conjunction with “take-out.”

Page 5: カタログ ASLINKPOKAYOKE 英語 PDF · POKA-YOKE is a global common word The POKAYOKE system comprising the AnyWire POKAYOKE terminal provides a solution to this problem simply

<Cell production>Application 3

POKAYOKE terminal for “Cell production”

<Kitting: Tray service>Application 4

POKAYOKE terminal for “Kitting: Tray service” process

ASLINKPOKAYOKE series

ASLINKPOKAYOKE series

04

Applications

The third application is “cell production.”

The “cell production” method has become more common at production sites of “high-mix and low-volume production.”In this method in which one worker is in charge of the initial to the end of the assem-bly process, there are multiple processes, and if the worker makes any mistake, it is hard to make up for it.

Very small type which can be installed at a narrow opening and the end sur face o f a column plate is available in the POKAYOKE terminal lineup, and is also most suitable for cell production.

The fourth application is “Kitting: Tray service.”

Work in which parts which are necessary for manufac-turing of a certain product are collected in one box (kit box) as one kit is called “kitting.”

The ultimate objectives of the take-out process and kitting are the same, how-ever, detailed work instruc-tions such as quantity and sequence of take-out are required for kitting.

POKAYOKE terminal is also used at such kitting sites.

Page 6: カタログ ASLINKPOKAYOKE 英語 PDF · POKA-YOKE is a global common word The POKAYOKE system comprising the AnyWire POKAYOKE terminal provides a solution to this problem simply

Reason to select AnyWire 1

ADVANTAGE ①

BL227P

B-T

14P

02V-P

PO

KAYO

KE

Term

inal B

L2

27

XB

-T1

4P

02

V-C

PO

KAYO

KE

Term

inal B

L2

27

PB

-T1

4P

02

V-P

PO

KAYO

KE

Term

inal

BL2

27

XB

-T1

4P

02

V-C

PO

KAYO

KE

Term

inal

BL2

27

PB

-T0

7P

02

V-P

PO

KAYO

KE

Term

inal

BL2

27

XB

-T0

7P

02

V-C

PO

KAYO

KE

Term

inal

LINK IN R/W LINK IN R/W LINK IN R/W

Wide variety!Variation inresponse

and detection

Variation inresponse

and detection

Variation inindication

and instruction

Variation inindication

and instruction

Detection: Photoelectric transmission

Detection: Photoelectric transmission

Response: Lever switch

Response: Pushbutton

Detection: Photoelectric

reflection(downward)

Indication: 7-segment+

LED indication

Indication: LED indication

Indication: LED indication

Instruction: Door opening/closing

Installation method

also flexible!

Most POKAYOKE terminals can be installed on a 28mm diameter pipe rack as they are. Three types of pipe installation holders are available depending on workability at the time of installation (refer to the “Installation” at the right for details).Depending on the product, there is also a type to drill at the installation location and directly install with screws or bolts.

SUS pipe installation holder

Pipe installation example

ASLINKPOKAYOKE series05

ASLINKPOKAYOKE series

Advantage

Page 7: カタログ ASLINKPOKAYOKE 英語 PDF · POKA-YOKE is a global common word The POKAYOKE system comprising the AnyWire POKAYOKE terminal provides a solution to this problem simply

InstallationInstallation

SUS CorporationN seriesGreen frameCompatible with (outer diameter 28mm)

“H” holder

“H1” holder

“SUS” holder

ASLINKPOKAYOKE series

Holder for pipe installation product can be selected from the following three types.

“H” is a standard mounting holder, and is the easiest installation type due to the installation bolts being tightened from the front. There is a protruding section to the structure at the bottom of the holder.“H1” has no protrusion at the bottom of the holder, and is a type for which the bolt is tightened from the bottom (there is a protrusion on the back).

→Add “-H1” at the end of the standard model.

“SUS” is a dedicated holder installed on aluminum pipe of SUS Corporation.

→Change the end of the standard model from “-P” to “-PS.”

Reason to select AnyWire 1

ASLINKPOKAYOKE series

Advantage

06

This is the most standard

POKAYOKE terminal with

“LED indication,” “Lever switch” and

“Pipe installation.” This is our best

seller due to its simplicity.

If you are considering which type to

buy, select this type.

BasicBasic This type uses the 7-segment for

indication. Use this product when

you require indication of numerical

values such as the number of parts.

There are products with one digit display and two digit display.

Products of a lever switch and pushbuttons are available for a

response, allowing you to select your preference.

7-segment7-segmentLINK IN R/W

Surface emissionSurface emission

Opening/closing

of door

Opening/closing

of door

When parts are long, and openings are wide or you want to

detect by take-out operation and

eliminate response operation,

“Photoelectric transmission

type” is optimal.

PhotoelectrictransmissionPhotoelectrictransmission

BL2

27

PB

-T1

4P

02

V-P

PO

KAYO

KE

Term

inal B

L227X

B-T

14P

02V-C

PO

KAYO

KE

Term

inal

Touchdetection

Touchdetection

POKAYOKE terminal instructs on

the take-out location by opening/-

closing of door block openings

from which parts should not be

taken out. This is most effective for

prevention of mistake.

There are products with LED-indi-

cation only and with LED- indica-

tion and 7-segment variable four

digit display.

There are three types of response,

“lever switch,” “pushbutton” and

“downward re�ection,” and two

types of doors “a type that opens

vertically to the ground” and “a

type that opens horizontally to the ground.” They can be

selected according to various sites.

Also, a small and touch detection type POKAYOKE

terminal that is ideal for drug shelves and parts shelves

with many small boxes lined and capable of being

installed in any space, is available. It can be installed

on the side of a shelf board with double-sided tape. A surface-emission

POKAYOKE termi-

nal with a wide light-emission surface

that stands out even in dark places.

Visibility from a distance is also the best.

Page 8: カタログ ASLINKPOKAYOKE 英語 PDF · POKA-YOKE is a global common word The POKAYOKE system comprising the AnyWire POKAYOKE terminal provides a solution to this problem simply

ADVANTAGE ②

MELSEC sequencer manufactured by Mitsubishi Electric Corporation

・MELSEC-iQ-R series ・MELSEC-Q series・MELSEC-L series ・MELSEC iQ-F series・MELSEC-F series

Various open networks & PC buses

・CC-Link(Ver.1.10/Ver.2.00) ・PCI Express・CC-Link IE Field ・DeviceNet ・PROFIBUS・SLMP ・EtherNet/IP・Modbus/TCP

DeviceNet PROFIBUS Ethernet PCI Express

012345 6789 ABCDEF

MELSEC-LMELSEC-Q MELSEC-FMELSEC iQ-R MELSEC iQ-F

Because the AnyWire POKAYOKE terminal compatible with the MELSEC sequencer of Mitsubishi Electric

and many common industrial open networks can be used with general equipment, environments and tools,

there are no concerns even with the initial introduction.

07

Reason to select AnyWire 2

Compatible with various

controllers & networks!

ASLINKPOKAYOKE series

Advantage

ASLINKPOKAYOKE series

Page 9: カタログ ASLINKPOKAYOKE 英語 PDF · POKA-YOKE is a global common word The POKAYOKE system comprising the AnyWire POKAYOKE terminal provides a solution to this problem simply

ADVANTAGE ③

Slimmed-down!

Link connector (LP connector) is equipped as a standard on the POKAYOKE terminal transmission line (partially excluded). The link connector allows for branching and extension work without electric wire cutting and sheath stripping. Work time can also be reduced, and no electric wire or sheath waste, etc., is produced.

Conventional method Sho-Haisen method

Easy branching!

- Branching can be made even in the middle of wiring because of crimping.

- No waste is produced because an electric wire is not cut/sheath is not stripped.

- There is no difference between male and female, and are the same models, so it is easy to understand.

Address setting!Address setting method for the AnyWire POKAYOKE terminal is to use an address writerto read and write address in a non-contact state. Refer to page 29 for address setting. Refer to and con�rm by the product instruction manual of each product for details of each product.

Remote headAppearance ofARW-RH

Appearance ofARW-04

You can sandwich wire in a sleeve even in the middle or at the end of an electric wire.

Clamp with a dedicated tool to crimp.(See the accessory items.)

T-branch, 4-branch or extension is allowed.Working time is signi�cantly reduced.

ASLINKPOKAYOKE seriesAdvantage

Reason to select AnyWire 3

Of course, Sho-Haisen!

ASLINKPOKAYOKE series 08

Name of each part of ARW-04

Bundle of cables is on controller side···

The POKAYOKE terminal which “AnyWire of

Sho-Haisen” delivers is of course “POKAYOKE

[Sho-Haisen] terminal.”

Connection can be made only by

branching from the main line

without requiring connection

of individual terminals with a

controller in one-to-one wiring.

Ring for strap

Position of light emitting and receiving part

(yellow part)

POWER indication lamp

Comment indication part (7-segment 6 digits)

RH (Remote head)

Connection connector (Side)

POWER (CLEAR) button

R button

DOWN button

SELECT button

UP button

L button

SET button

Operation mode indication lamp

Page 10: カタログ ASLINKPOKAYOKE 英語 PDF · POKA-YOKE is a global common word The POKAYOKE system comprising the AnyWire POKAYOKE terminal provides a solution to this problem simply

Terminator(Waveform shaping module)

3. Terminator

2. Selection of terminal

4. Connector and cable

ASLINKPOKAYOKE series

System ConfigConfiguration of POKAYOKE system

Con�guration of the POKAYOKE system requires a “Master unit” and “Terminator” in addition to the POKAYOKE terminal,

and an “electric wire” and “connector” connecting them, and “24V DC stabilized power source.”

R61P

N a r r o w d o w n t h e P O K A Y O K E terminals you want to use wi th reference to features of individual products such as

“indication, instruction,” “response, detection” “how to install,” and site environment and purpose for introduction.

“Number of occupied points” and “consuming current” vary with each product, which causes the number of connectable units to vary.Suf�ciently con�rm the speci�cations referring to the catalog and Product Guide (Product instruction manual) to determine the con�guration.

*A compatible l ineup for every product feature can be con�rmed in the product matrix diagram on pages 05 to 06 and pages 11 to 12.

A l l POKAYOKE te rmina ls a re shipped with a link connector (LP connector) connected.The link connector is a crimp type connector with no distinction between female and male, and the branch point can be provided at any location without cutting the main line.If a “4-core �at cable” which is the same as that used for the terminal i s used , w i r i ng wo rk can be performed easily and quickly.

The AnyWire Terminator is different from “Terminal resistor” in general, and incorporates a circuit to form a transmission waveform. Make sure to install one piece in one system at the most remote end of the branch.

MELSEC-L MELSEC-Q MELSEC-FMELSEC iQ-F

DC24V

MELSEC iQ-R

1. Selection of master unitSelect the master unit to be used for your POKAYOKE system according to the sequencer and open network to be used.

For the MELSEC sequencer

For CC-Link・CC-Link IE Field

For PCI Express

For DeviceNet・PROFIBUSEtherNet/IP・Modbus/TCP

SLMP

ASLINKPOKAYOKE series09    

Page 11: カタログ ASLINKPOKAYOKE 英語 PDF · POKA-YOKE is a global common word The POKAYOKE system comprising the AnyWire POKAYOKE terminal provides a solution to this problem simply

ASLINKPOKAYOKE series

ASLINKPOKAYOKE seriesSpecification

10

ASLINKPOKAYOKE basic transmission specifications

■Performance specifications

■Transmission cycle time

■General specifications

■Precautions on transmission

*Descriptions are for representative general specifications. There are exceptions depending on the product. Refer to and confirm the instruction manual for details.

Ambient temperature use

Ambient temperature storage

Ambient humidity use

Ambient humidity storage

Atmosphere use

Altitude use *1

Pollution level *2

0 to 55℃

-25℃ to 75℃

No corrosive gas

0 to 2000m

2 or less

10 to 90%RH, No condensation

*1 Do not use or store the AnyWireASLINK equipment in an environment pressurized above the atmospheric pressure at altitude 0m. Malfunction may result.*2 This is an index showing the degree of generation of conducting substance in an environment where the equipment is used. Pollution level 2 means generation of

non-conducting pollution only. However, temporary conduction may occur by accidental condensation in this environment.

Number of connection points

Transmission method

Connection mode

Transmission protocol

Error control

Number of connection I/O points

RAS function

Electric wire used

Up to 128 units

DC power supply superimposed total frame/cyclic method

T-branch method, multi-drop method, star wiring method, tree branch method

AnyWireASLINK protocol

Double check, checksum

Up to 512 points (Input 256 points/output 256 points)However, up to 128 points for FX3U-128ASL-M (input + output ≤ 128 points) (number of input points are prioritized in case of input + output > 128 points) Up to 448 points for FX5-ASL-M (input + output ≤ 448 points) (input up to 256 points, output up to 256 points)*4

Transmission line disconnection detection function, transmission line short-circuit detection function, transmission circuit drive power drop detection function ID (address) redundant/non-setting detection function

- General-purpose 2-wire/4-wire cable (VCTF, VCT 0.75 to 1.25mm2, rated temperature 70ºC)- General-purpose electric wire (0.75 to 1.25mm2, rated temperature 70ºC) - Dedicated �at cable(0.75mm /1.25mm2, rated temperature 90ºC)

Transmission clock

Transmission distance/supply current *3

27kHz (37μs)

Size Transmission distance DP-DN allowable supply current

50m or less

Exceeding 50m, 100m or less

Exceeding 100m, 200m or less

50m or less

Exceeding 50m, 100m or less

Exceeding 100m, 200m or less

50m or less

Exceeding 50m, 100m or less

Exceeding 100m, 200m or less

2A or less

1A or less

0.5A or less

1.2A or less

0.6A or less

0.3A or less

0.8A or less

0.4A or less

0.2A or less

1.25mm2

0.75 mm2

0.5mm2

Transmission cycle time is time to update input and output data of the master unit and all slave units..

Transmission I/O point number setting

1 transmission cycle time 2.3ms 3.5ms 5.9ms 10.6ms

512 points(Input 256 points, output 256 points)

256 points(Input 128 points, output 128 points)

128 points(Input 64 points, output 64 points)

64 points(Input 32 points, output 32 points)

◇ series to 24V and 0V at a position where 4-core running starts together (immediately below the master unit in general connection state). (Maximum

allowable current 5A/DC24V)

→→ In both cases when collectively supplying from the power source for master and when supplying from local power source, these shall be inserted.

*3 Total length also includes the cable section of the terminal with cable. Size of the cable section of the terminal with cable is not included under this condition.*4 If used in a con�guration other than the combination of GX Works3 (Ver. 1.047Z or higher) and FX5U CPU unit (ver. 1.100 or higher), the maximum number of points is 384 (input + output ≤ 384 points) (input up to 256 points, output up to 256 points)

Page 12: カタログ ASLINKPOKAYOKE 英語 PDF · POKA-YOKE is a global common word The POKAYOKE system comprising the AnyWire POKAYOKE terminal provides a solution to this problem simply

Indication, instruction method

Response, detection method

BL227XB-K02V-P BL227XB-K02VN-P

BL227XB-K06MN-PBL227XB-K06M-P

Pushbutton switch typeLever switch type Photoelectric reflection type (downward) Photoelectric transmission type

BL227XB-K71VL-P

BL227XB-K72VL-P

BL227XB-K71ML-P

BL227XB-K72ML-P

BL227XB-K71VN-P

BL227XB-K72VN-P

BL227XB-K71MN-P

BL227XB-K72MN-P

BL227XB-K71V-P

BL227XB-K72V-P

BL227XB-K71M-P

BL227XB-K72M-P

List of POKAYOKE terminal products

BL227XB-K02VL-P

BL227XB-K06ML-P

BL227PB-T07P02V-P

M4

BL227XB-T07P02V-CBL227PB-T14P02V-PBL227XB-T14P02V-C

BL227PB-T07P06M-PBL227XB-T07P06M-CBL227PB-T14P06M-PBL227XB-T14P06M-C

LEDindication

only

7-segment indication

+LED

indication

Standardtype

Dooropening/closing

+LED

indication

Selection type

Combination type

Selection type

Combination type

Selection type

Combination type

Selection type

Combination type

Selection type

Combination type

Selection type

Combination type

Selection type

Combination type

Selection type

Combination type

Selection type

詳細はP.14へ

Refer topage 14

for details.

詳細はP.13へ

Refer to page 13for details.

詳細はP.13へ

Refer to page 13for details.

詳細はP.13へ

Refer to page 13for details.

詳細はP.15へ

Refer topage 15

for details.

詳細はP.15へ

Refer topage 15

for details.

詳細はP.15へ

Refer topage 15

for details.

BL227XB-FK04VL-P

BL227XB-F2K04VL-P

BL227XB-FK04VN-P

BL227XB-F2K04VN-P

BL227XB-FK04V-P

BL227XB-F2K04V-P

BL227XB-FK06ML-P

BL227XB-F2K08ML-P

BL227XB-FK06MN-P

BL227XB-F2K08MN-P

BL227XB-FK06M-P

BL227XB-F2K08M-P

詳細はP.17へ

Refer topage 17

for details.

詳細はP.17へ

Refer topage 17

for details.

詳細はP.17へ

Refer topage 17

for details.

BL227XB-RK04VL-P

BL227XB-R2K04VL-P

BL227XB-RK04VN-P

BL227XB-R2K04VN-P

BL227XB-RK04V-P

BL227XB-R2K04V-P

BL227XB-RK06ML-P

BL227XB-R2K08ML-P

BL227XB-RK06MN-P

BL227XB-R2K08MN-P

BL227XB-RK06M-P

BL227XB-R2K08M-P

詳細はP.18へ

Refer topage 18

for details.

詳細はP.18へ

Refer topage 18

for details.

詳細はP.18へ

Refer topage 18

for details.

BL227XB-F1K04VL-P

BL227XB-F3K04VL-P

BL227XB-F1K04VN-P

BL227XB-F3K04VN-P

BL227XB-F1K04V-P

BL227XB-F3K04V-P

BL227XB-F1K06ML-P

BL227XB-F3K08ML-P

BL227XB-F1K06MN-P

BL227XB-F3K08MN-P

BL227XB-F1K06M-P

BL227XB-F3K08M-P

詳細はP.19へ

Refer topage 19

for details.

詳細はP.19へ

Refer topage 19

for details.

詳細はP.19へ

Refer topage 19

for details.

Metalarm

(vertical)

Plasticarm

(vertical)

Metalarm

(horizontal)

BL227XB-FK7V4VL-P

BL227XB-F2K7V4VL-P

BL227XB-FK7V4VN-P

BL227XB-F2K7V4VN-P

BL227XB-FK7V4V-P

BL227XB-F2K7V4V-P

BL227XB-FK7V4ML-P

BL227XB-F2K7V4ML-P

BL227XB-FK7V4MN-P

BL227XB-F2K7V4MN-P

BL227XB-FK7V4M-P

BL227XB-F2K7V4M-P

詳細はP.20へ

Refer topage 20

for details.

詳細はP.20へ

Refer topage 20

for details.

詳細はP.20へ

Refer topage 20

for details.

BL227XB-RK7V4VL-P

BL227XB-R2K7V4VL-P

BL227XB-RK7V4VN-P

BL227XB-R2K7V4VN-P

BL227XB-RK7V4V-P

BL227XB-R2K7V4V-P

BL227XB-RK7V4ML-P

BL227XB-R2K7V4ML-P

BL227XB-RK7V4MN-P

BL227XB-R2K7V4MN-P

BL227XB-RK7V4M-P

BL227XB-R2K7V4M-P

詳細はP.21へ

Refer topage 21

for details.

詳細はP.21へ

Refer topage 21

for details.

詳細はP.21へ

Refer topage 21

for details.

BL227XB-F1K7V4VL-P

BL227XB-F3K7V4VL-P

BL227XB-F1K7V4VN-P

BL227XB-F3K7V4VN-P

BL227XB-F1K7V4V-P

BL227XB-F3K7V4V-P

BL227XB-F1K7V4ML-P

BL227XB-F3K7V4ML-P

BL227XB-F1K7V4MN-P

BL227XB-F3K7V4MN-P

BL227XB-F1K7V4M-P

BL227XB-F3K7V4M-P

詳細はP.22へ

Refer topage 22

for details.

詳細はP.22へ

Refer topage 22

for details.

詳細はP.22へ

Refer topage 22

for details.

Metalarm

(vertical)

Metalarm

(vertical)

Plasticarm

(vertical)

BL227XB-F04VL-PBL227XB-F04V-PRefer topage 23

for details.

Refer topage 23

for details.

Metalarm

(horizontal)

IndependentIndependent

Interlocked

φ28 φ28 φ28

Products with marked bold letter type are standard inventory.Other products are made-to-order products.

Two digitOne digit

One digit

Two digit

One digit

Two digit

Sta

ndar

dco

mp

actD

oo

ro

pen

ing

/cl

osi

ng+

LED

ind

icat

ion

Sta

ndar

dco

mp

actD

oo

ro

pen

ing

/cl

osi

ng+

+LE

Din

dic

atio

n

7-segmentindication

variablefour digit

Inde-pendentInde-pendent

Inter-lockedInter-locked

Inde-pendentInde-pendent

Inter-lockedInter-locked

Inde-pendentInde-pendent

Inter-lockedInter-locked

Inde-pendentInde-pendent

Inter-lockedInter-locked

Inde-pendentInde-pendent

Inter-lockedInter-locked

Inde-pendentInde-pendent

Inter-lockedInter-locked

Inde-pendentInde-pendent

Inter-lockedInter-locked

Inde-pendentInde-pendent

Inter-lockedInter-locked

Inde-pendentInde-pendent

Inter-lockedInter-locked

Inde-pendentInde-pendent

Inter-lockedInter-locked

Inde-pendentInde-pendent

Inter-lockedInter-locked

Inde-pendentInde-pendent

Inter-lockedInter-locked

Inde-pendentInde-pendent

Inter-lockedInter-locked

ASLINKPOKAYOKE series

Variations

11 ASLINKPOKAYOKE series

Page 13: カタログ ASLINKPOKAYOKE 英語 PDF · POKA-YOKE is a global common word The POKAYOKE system comprising the AnyWire POKAYOKE terminal provides a solution to this problem simply

ASLINKPOKAYOKE series

ASLINKPOKAYOKE series

Variations

12

◆ Indicated by icon

Mounting with M4 screw

Mounting with double-sided tape

M4

Mounting with φ28 pipeφ28

◆The color of LED indication

*The actual color is close to orange

◆ Model *The following is a simpli�ed description. Keep this in mind as a reference because there are some exceptions.

Indication, instruction method

Response, detection method

B292XB-02VL

B292XB-06ML

Touch type (wire duct type) Touch type (surface-emission type)

List of POKAYOKE terminal products

POKAYOKE terminal type standard

BL2101XB-02VL-P

LEDindication

only

Selection type

Combination type

Refer to page 24for details.

Refer to page 24for details.

Refer to page 24for details.

Double-sidedtape

Mounting with magnet

Magnet

Selection type

Combination type Two digit

Selection of one color from seven colors

Door opening/closing and LED indication are “interlocked.”Door opening/closing and LED indication are “independent.”

7-segment display “one digit”

7-segment display “two digit”

7-segment variable display “four digit”

RGB each colorIndependent ON/OFF

Metal arm (metallic) andthe angle of closed door is “Vertical.”Metal arm (metallic) andthe angle of closed door is “Horizontal.”Plastic arm (resin) andthe angle of closed door is “Vertical.”*The door angle of door opening/closing type POKAYOKE terminal is an appropriate one.

One digit

Ex. 1) BL227XB-FK7V4VN-P

27

XBInput/output

BL2Four wire type

(isolated)

FMetal/vertical/

interlocked

KStandard small size

717-segment

and one digit

08

06

04

02 VLED selection type

NPushbutton

LDownward re�ection

(No mark)Lever

MLED combination type

727-segment

and two digit

7V47-segment

variable four digit*The number of digits can

be changed by setting.

(No mark)Standard type

F1Plastic/vertical/

interlocked

F2Metal/vertical/independent

F3Plastic/vertical/

independent

RMetal/horizontal/

interlocked

R2Metal/horizontal/

independent

27

Chassiscategory

BL2Connection

method

BL2Four wire type

(isolated)

BL2

XB F K 7V4 V N-Input/output

category LED indication Input method

-P“H” holder

200 mm cable withLP connector

“H1” holder200 mm cable with

LP connector

“SUS” holder200 mm cable with

LP connector

-P-H1

-PS

* Refer to pages 05 to 06 for details of holders.

-PHolder & cablespeci�cationsSize shape

I/O points or7-segment

speci�cation

Door arm materialDirection andI/O interlock

Ex. 2) BL227PB-T07P02V-P

・In the case of lever switch type, pushbutton switch type, photoelectric reflection type (downward) product

・In the case of photoelectric transmission type product

27

XBInput/output

TTransmission type

07P70mm/dust-proof

02 VLED selection type

-PLight-emission side

-CLight-reception side

MLED combination type

0614P140mm/dust-proof

PBOutput

27

PB T 07P 02 V -P-LED indication

Light-emission/reception class

Size protectivestructure I/O points

Productcategory

IN

TOUCH

LINK

R/W

IN

TOUCH

LINK

R/W

Double-sidedtape

Magnet

“Selection type”:The indication color of this

terminal can be selected from one

of the seven colors on the right.

“Combination type”:The indication color of this

terminal can be set from one of

the seven colors on the right by

a combination of RGB.

Green

Red

Blue

Yellow*

Sky blue

Purple

White

Chassiscategory

Connectionmethod

Input/outputcategory

Inde-pendentInde-pendent

Inter-lockedInter-locked

variablefour digit

Page 14: カタログ ASLINKPOKAYOKE 英語 PDF · POKA-YOKE is a global common word The POKAYOKE system comprising the AnyWire POKAYOKE terminal provides a solution to this problem simply

Products

13

ASLINKPOKAYOKE series

ASLINKPOKAYOKE series *The mark shows a made-to-order product.

Indication: LED (selection, combination)

Standard compact

◆Address writer

◆ Option

*φ28 pipe installation holder is included with the POKAYOKE terminal (φ28 pipe installation type). Single part is an option for change of installation and repair.

・Common

◇Response: Lever switch

◇Response: Pushbutton switch

◇Detection: Photoelectric downward reflection type

φ28 pipe

φ28 pipe Open

Open

BL227XB-K02V-P1 1BL227XB-K06M-P1 3

Lever switch

Lever switch

◆ LED indication: (selection type, combination type) Lever switch type 31

31L E D

BL227XB-K02V-PBL227XB-K06M-P

One colorselection type

Combinationtype 356

356

◆ LED indication: (selection type, combination type) Pushbutton switch type

φ28 pipe

φ28 pipe Open

Open

BL227XB-K02VN-P1 1BL227XB-K06MN-P1 3

Pushbutton 3131Pushbutton

L E D

L E D

One colorselection type

Combinationtype

BL227XB-K02VN-PBL227XB-K06MN-P

356356

φ28 pipe OpenBL227XB-K02VL-P3561 1Downwardreflection

◆ LED indication: (selection type, combination type) Photoelectric downward re�ection 31

*The above models are equipped with “H” holder as a standard.*When installing “H1” holder, add “-H1” at the end of the standard model.*When installing “SUS” holder, change the end of the standard model from “-P” to “-PS.”

One colorselection type

Combinationtype φ28 pipe OpenBL227XB-K06ML-P3561 3Downward

reflection 31

BL227XB-K02VL-PBL227XB-K06ML-P

Indication, instruction Installation

Number ofI/O points

Input Output Model

Response, detection

Page of Outline

DimensionalDrawings

Standardprice (¥)

Consumptioncurrent(mA)Trans-mission

sideI/Oside

Indication, instruction Installation

Number ofI/O points

Input Output Model

Response, detection

Page of Outline

DimensionalDrawings

Standardprice (¥)

Consumptioncurrent(mA)Trans-mission

sideI/Oside

Indication, instruction Installation

Number ofI/O points

Input Output Model

Response, detection

Page of Outline

DimensionalDrawings

Standardprice (¥)

Consumptioncurrent(mA)Trans-mission

sideI/Oside

A027-HP28-5P φ28 pipe[H] holder φ28 pipe installation holder lower tightening type (including 5 pieces)

A027-HP28-H1-5P φ28 pipe[H1] holder

A027-HP-SUS2SUS pipe[SUS] holder

Standard price (¥)Product speci�cations ModelInstallation

Open

Open

Open

Open

Page of OutlineDimensional

Drawings

343434-Terminal A027-LES-01-5PReplacement rubber lever set

(including cover, lever, ring respectively 5 pieces)

φ28 pipe installation holder back tightening type (including 5 pieces)

SUS pipe installation holder (including 1 piece)

OpenARW-04Non-contact typeAddress writer (general-purpose)

OpenARW-04-RHNon-contact typeAddress writer ARW-04 + Infrared ray remote head

OpenARW-RHNon-contact typeInfrared ray remote head for address writer

34--

Standard price (¥)Product speci�cations ModelInstallationPage of OutlineDimensional

Drawings

Page 15: カタログ ASLINKPOKAYOKE 英語 PDF · POKA-YOKE is a global common word The POKAYOKE system comprising the AnyWire POKAYOKE terminal provides a solution to this problem simply

ASLINKPOKAYOKE series

ASLINKPOKAYOKE series

Products

14

1

BL227PB-T14P02V-PBL227XB-T14P02V-C

BL227PB-T07P02V-PBL227XB-T07P02V-C

33

55

1 1

11 1

A027-T07PC

A027-TPSM4-5P

A027-T14PCA027-TSM4-5P

A027-T07PHP28-H1A027-T14PHP28-H1

M4 screw

M4 screw

M4 screw

M4 screw

300300

10001000

3131

3131

◆ LED indication: (selection type, combination type)Photoelectric transmission type(Dust-proof: 70mm short)

・Option

◆ LED indication: (selection type, combination type)Photoelectric transmission type(Dust-proof: 140mm long)

◆Address writerARW-04

ARW-04-RHARW-RH

34--

Open

Open

Open

Open152.5202.5

3 BL227PB-T07P06M-PBL227XB-T07P06M-C

331 3

M4 screw

M4 screw

300300

3131 Open

Open152.5202.5

162.5252.5

BL227PB-T14P06M-PBL227XB-T14P06M-C

55

31 3

M4 screw

M4 screw

10001000

3131 Open

Open162.5252.5

L E D

L E D

L E D

L E D

BL227XB-T07P02V-CBL227XB-T07P06M-C

BL227PB-T07P02V-PBL227PB-T07P06M-P

BL227XB-T14P02V-CBL227XB-T14P06M-C

BL227PB-T14P02V-PBL227PB-T14P06M-P

*The occupied points of the light-reception side (model: BL227XB and subsequent models) are as described above. However, “only input specification” is available on CSP+ (profile for GX Works) to prevent output duplication errors with the light-emission side. Although there is no problem with use, please note that there are differences from the actual number of I/O occupied points.

*The occupied points of the light-reception side (model: BL227XB and subsequent models) are as described above. However, “only input specification” is available on CSP+ (profile for GX Works) to prevent output duplication errors with the light-emission side. Although there is no problem with use, please note that there are differences from the actual number of I/O occupied points.

Transmission (light emission)Transmission (light reception)Transmission (light emission)Transmission (light reception)

Transmission (light emission)Transmission (light reception)Transmission (light emission)Transmission (light reception)

Lightaxis

Maximumdetectiondistance(mm)

Indication, instruction Installation

Number ofI/O points

Input Output Model

Response, detection

Page of Outline

DimensionalDrawings

Standardprice (¥)

Consumptioncurrent(mA)

I/Oside

Trans-mission

side

Lightaxis

Maximumdetectiondistance(mm)

Indication, instruction Installation

Number ofI/O points

Input Output Model

Response, detection

Page of Outline

DimensionalDrawings

Standardprice (¥)

Consumptioncurrent(mA)

I/Oside

Trans-mission

side

One colorselection type

One colorselection type

Combinationtype

Combinationtype

One colorselection type

One colorselection type

Combinationtype

Combinationtype

Open

Open

Open

Open

Open

Open

M4 screw

M4 screw

M4 screw

M4 screw

Protective bracket for transmission type terminal (Dust-proof: 70mm)(including 1 piece)

φ28 pipe

φ28 pipe

φ28 pipe installation holder for transmission type terminal (Dust-proof: 70mm)(including 1 piece)φ28 pipe installation holder for transmission type terminal (Dust-proof: 140mm)(including 1 piece)

Protective bracket for transmission type terminal (Dust-proof: 140mm)(including 1 piece)Installation screw set for transmission type terminal(for product with no protective bracket) (including 5 pieces)Installation screw set for transmission type terminal(for product with protective bracket)(including 5 pieces)

3131

3131

--

Standard price (¥)Product speci�cations ModelInstallationPage of OutlineDimensional

Drawings

Open

Open

Open

Non-contact typeAddress writer (general-purpose)

Non-contact typeAddress writer ARW-04 + Infrared ray remote head

Non-contact typeInfrared ray remote head for address writer

Standard price (¥)Product speci�cations ModelInstallationPage of OutlineDimensional

Drawings

*The mark shows a made-to-order product.

Indication: LED (selection, combination) Detection: Photoelectric transmission type

Page 16: カタログ ASLINKPOKAYOKE 英語 PDF · POKA-YOKE is a global common word The POKAYOKE system comprising the AnyWire POKAYOKE terminal provides a solution to this problem simply

Products

15

ASLINKPOKAYOKE series

ASLINKPOKAYOKE series

◇Response: Lever switch

◇Response: Pushbutton switch

◇Detection: Photoelectric downward reflection type

Standard compact

Indication: 7-segment (one digit, two digit) + LED (selection, combination)

32 φ28 pipe BL227XB-K71VN-P1 5

◆ 7-segment (one digit, two digit)+ LED indication (selection type, combination type) Pushbutton switch type

*The above models are equipped with “H” holder as a standard.*When installing “H1” holder, add “-H1” at the end of the standard model.*When installing “SUS” holder, change the end of the standard model from “-P” to “-PS.”

Open486

◆ 7-segment (one digit, two digit)+ LED indication (selection type, combination type) Lever switch type

32 φ28 pipe OpenBL227XB-K71V-P1 5

BL227XB-K71V-PBL227XB-K71M-P

BL227XB-K71VN-PBL227XB-K71MN-P

BL227XB-K71VL-PBL227XB-K71ML-P

BL227XB-K72V-PBL227XB-K72M-P

BL227XB-K72VN-PBL227XB-K72MN-P

BL227XB-K72VL-PBL227XB-K72ML-P

ARW-04

ARW-04-RHARW-RH

34--

A027-HP28-5PA027-HP28-H1-5PA027-HP-SUS2

343434- A027-LES-01-5P

◆Address writer

◆ Option ・Common

486Lever switch

32 φ28 pipe OpenBL227XB-K72V-P1 9 486Lever switch

32 φ28 pipe OpenBL227XB-K71M-P1 7 486Lever switch

32 φ28 pipe OpenBL227XB-K72M-P1 11 486Lever switch

Open

Open

Open

Open

Open

Open

Open

Pushbutton

32 φ28 pipe BL227XB-K72VN-P1 9 Open486Pushbutton

32 φ28 pipe BL227XB-K71MN-P1 7 Open486Pushbutton

32 φ28 pipe BL227XB-K72MN-P1 11 Open486Pushbutton

32 φ28 pipe BL227XB-K71VL-P1 5

◆ 7-segment (one digit, two digit)+ LED indication (selection type, combination type) Photoelectric downward re�ection

Open486Downwardreflection

32 φ28 pipe BL227XB-K72VL-P1 9 Open486Downwardreflection

32 φ28 pipe BL227XB-K71ML-P1 7 Open486Downwardreflection

32 φ28 pipe BL227XB-K72ML-P1 11 Open486Downwardreflection

Indication, instruction Installation

Number ofI/O points

Input Output Model

Response, detection

Page of Outline

DimensionalDrawings

Standardprice (¥)

Consumptioncurrent(mA)

I/Oside

Trans-mission

side

Indication, instruction Installation

Number ofI/O points

Input Output Model

Response, detection

Page of Outline

DimensionalDrawings

Standardprice (¥)

Consumptioncurrent(mA)

I/Oside

Trans-mission

side

Indication, instruction Installation

Number ofI/O points

Input Output Model

Response, detection

Page of Outline

DimensionalDrawings

Standardprice (¥)

Consumptioncurrent(mA)

I/Oside

Trans-mission

side+7-

segment One colorselection typeOne digit

+Combinationtype

7-segmentTwo digit

LED

7-segment

One colorselection type

One digit

+Combinationtype

7-segmentTwo digit

LED

+7-segment One color

selection typeOne digit

+Combinationtype

7-segmentTwo digit

LED

7-segment

One colorselection type

One digit

+Combinationtype

7-segmentTwo digit

LED

+7-segment One color

selection typeOne digit

+Combinationtype

7-segmentTwo digit

LED

7-segment

One colorselection type

One digit

+Combinationtype

7-segmentTwo digit

LED

*φ28 pipe installation holder is included with the POKAYOKE terminal (φ28 pipe installation type). Single part is an option for change of installation and repair.

Standard price (¥)Product speci�cations ModelInstallationPage of OutlineDimensional

Drawings

Standard price (¥)Product speci�cations ModelInstallationPage of OutlineDimensional

Drawings

Replacement rubber lever set (including cover, lever, ring respectively 5 pieces)

φ28 pipe

φ28 pipe

SUS pipe

Terminal

Non-contact typeAddress writer (general-purpose)

Non-contact typeAddress writer ARW-04 + Infrared ray remote head

Non-contact typeInfrared ray remote head for address writer

*The mark shows a made-to-order product.

[H] holder φ28 pipe installation holder lower tightening type (including 5 pieces)

[H1] holder

[SUS] holder

φ28 pipe installation holder back tightening type (including 5 pieces)

SUS pipe installation holder (including 1 piece)

Page 17: カタログ ASLINKPOKAYOKE 英語 PDF · POKA-YOKE is a global common word The POKAYOKE system comprising the AnyWire POKAYOKE terminal provides a solution to this problem simply

Products

16

ASLINKPOKAYOKE series

ASLINKPOKAYOKE series

Standard small door opening/closing type variations

Inde-pendentInde-pendent

Inter-lockedInter-locked

□Display method LED indication and 7-segment display

There are two types of methods, “LED indication only” and “LED and 7-segment display” as display methods other than ejection instruction by door opening and closing operations.Either “Selection type (one of seven colors)” or “7-color display by RGB combination” can be selected for each LED indication. ◇Selection type (one of seven colors): select LED indication color by using address writer or from the top. The terminal lights with only the selected color at the time of output. ◇7-color display by RGB combination: As each LED of RGB (red, green and blue) can be individually turned on/off, the colors can be changed from the top at any time.And 7-segment display is “7-segment variable four digit display.” The number of such digits can be selected by using an address writer in advance (one – four digits).

□Instruction method Operation of door arm

The two types of methods of “Interlocked” and “Independent” are available also for ejection instruction by door opening and closing operations. ◇Interlocked: LED indication and door opening operations are collectively controlled with one output bit. “Interlocked” is used when opening the door at the same time as the LED lights. ◇Independent: LED indication and door opening operations are individually controlled with separate output bits. “Independent” is used when LED lighting and door opening operations are not interlocked.

The indication color: Green

The indication color: Red

The indication color: Blue

The indication color: Yellow

The indication color: Sky blue

The indication color: Purple

The indication color: White

The indication color: Green

The indication color: Red

The indication color: Blue

The indication color: Yellow

The indication color: Sky blue

The indication color: Purple

The indication color: White

◆There are various specifications of the standard small door opening/closing type POKAYOKE terminal, and

the model is determined by their combination. The optimum POKAYOKE terminal can be selected according

to the application.

Selection type Combination type

Metal arm vertical Plastic arm verticalMetal arm horizontal

Door opening operations and LED indication are “independent”Door opening operations and

LED indication are “interlocked”

Door opening operations and LED lighting can be individually controlled. (Also they can be simultaneously controlled.)Door opening operations and

LED lighting are simultaneous.

LED indication only

Selection type Combination type

*The images are in the case of four digit display.

LED indication+

7-segment variable four digit

Selection type Combination type

□Instruction method Material and stationary position of door arm

There are two types of door arms, a “metal arm” and a “plastic arm,” and the metal arm has two types, a “vertical type” and a “horizontal type” depending on its stationary position (origin). ◇Metal arm vertical: A metal arm is mounted vertically. This is the most common specification. ◇Metal arm horizontal: A metal arm is mounted horizontally. Select this to open and close a lid-shaped object such as a part box.  ◇Plastic arm vertical: A plastic arm is mounted vertically. This is convenient for small spaces as a simple door has been already mounted.

variablefour digit

variablefour digit

Inde-pendentInde-pendentInter-

lockedInter-locked

Page 18: カタログ ASLINKPOKAYOKE 英語 PDF · POKA-YOKE is a global common word The POKAYOKE system comprising the AnyWire POKAYOKE terminal provides a solution to this problem simply

Products

17

ASLINKPOKAYOKE series

ASLINKPOKAYOKE series

◇Response: Lever switch

◇Response: Pushbutton switch

◇Detection: Photoelectric downward reflection type

Instruction: Door opening/closing (metal arm vertical) + LED (selection, combination)

◆ Door opening, closing (metal arm vertical)+ LED indication (selection type, combination type)Interlocking type, independent type Pushbutton switch type

*The above models are equipped with “H” holder as a standard.*When installing “H1” holder, add “-H1” at the end of the standard model.*When installing “SUS” holder, change the end of the standard model from “-P” to “-PS.”

◆ Door opening, closing (metal arm vertical)+ LED indication (selection type, combination type)Interlocking type, independent type Lever switch type

32 φ28 pipe OpenBL227XB-FK04V-P2 1 Standby 19Motion 522Standby 19Motion 522Standby 19Motion 522Standby 19Motion 522

6Lever switch

32 φ28 pipe OpenBL227XB-F2K04V-P2 2 6Lever switch

32 φ28 pipe OpenBL227XB-FK06M-P2 3 6Lever switch

32 φ28 pipe OpenBL227XB-F2K08M-P2 4 6Lever switch

32 BL227XB-FK04VN-P2 1 6Pushbutton

32 BL227XB-F2K04VN-P2 2 6Pushbutton

32 BL227XB-FK06MN-P2 3 6Pushbutton

32 BL227XB-F2K08MN-P2 4 6Pushbutton

32 BL227XB-FK04VL-P2 1 6Downwardreflection

32 BL227XB-F2K04VL-P2 2 6Downwardreflection

32 BL227XB-FK06ML-P2 3 6Downwardreflection

32 BL227XB-F2K08ML-P2 4 6Downwardreflection

◆ Door opening, closing (metal arm vertical)+ LED indication (selection type, combination type)Interlocking type, independent type Photoelectric downward re�ection

BL227XB-FK04V-PBL227XB-F2K04V-PBL227XB-FK06M-PBL227XB-F2K08M-P

BL227XB-FK04VN-PBL227XB-F2K04VN-PBL227XB-FK06MN-PBL227XB-F2K08MN-P

BL227XB-FK04VL-PBL227XB-F2K04VL-PBL227XB-FK06ML-PBL227XB-F2K08ML-P

Standard compact

Indication, instruction Installation

Number ofI/O points

Input Output Model

Response, detection

Page of Outline

DimensionalDrawings

Standardprice (¥)

Consumptioncurrent(mA)

I/Oside

Trans-mission

side

Indication, instruction Installation

Number ofI/O points

Input Output Model

Response, detection

Page of Outline

DimensionalDrawings

Standardprice (¥)

Open

Open

Open

Open

Consumptioncurrent(mA)

I/Oside

Standby 19Motion 522Standby 19Motion 522Standby 19Motion 522Standby 19Motion 522

Trans-mission

side

+ One colorselection type

+ Combinationtype

LED

+ Combinationtype

LED

+ One colorselection type

+ One colorselection type

+ Combinationtype

LED

+ Combinationtype

LED

+ One colorselection type

+ One colorselection type

+ Combinationtype

LED

+ Combinationtype

LED

+ One colorselection type

φ28 pipe

φ28 pipe

φ28 pipe

φ28 pipe

Indication, instruction Installation

Number ofI/O points

Input Output Model

Response, detection

Page of Outline

DimensionalDrawings

Standardprice (¥)

Open

Open

Open

Open

Consumptioncurrent(mA)

I/Oside

Standby 19Motion 522Standby 19Motion 522Standby 19Motion 522Standby 19Motion 522

Trans-mission

side

φ28 pipe

φ28 pipe

φ28 pipe

φ28 pipe

ARW-04

ARW-04-RHARW-RH

34--

A027-HP28-5PA027-HP28-H1-5PA027-HP-SUS2

343434- A027-LES-01-5P

◆Address writer

◆ Option ・Common

Open

Open

Open

Open

Open

Open

Open*φ28 pipe installation holder is included with the POKAYOKE terminal (φ28 pipe installation type). Single part is an option for change of installation and repair.

Standard price (¥)Product speci�cations ModelInstallationPage of OutlineDimensional

Drawings

Standard price (¥)Product speci�cations ModelInstallationPage of OutlineDimensional

Drawings

Replacement rubber lever set (including cover, lever, ring respectively 5 pieces)

φ28 pipe

φ28 pipe

SUS pipe

Terminal

Non-contact typeAddress writer (general-purpose)

Non-contact typeAddress writer ARW-04 + Infrared ray remote head

Non-contact typeInfrared ray remote head for address writer

*The mark shows a made-to-order product.

[H] holder φ28 pipe installation holder lower tightening type (including 5 pieces)

[H1] holder

[SUS] holder

φ28 pipe installation holder back tightening type (including 5 pieces)

SUS pipe installation holder (including 1 piece)

Inde-pendentInde-pendent

Inter-lockedInter-locked

Inde-pendentInde-pendent

Inter-lockedInter-locked

Inde-pendentInde-pendent

Inter-lockedInter-locked

Inde-pendentInde-pendent

Inter-lockedInter-locked

Inde-pendentInde-pendent

Inter-lockedInter-locked

Inde-pendentInde-pendent

Inter-lockedInter-locked

Page 19: カタログ ASLINKPOKAYOKE 英語 PDF · POKA-YOKE is a global common word The POKAYOKE system comprising the AnyWire POKAYOKE terminal provides a solution to this problem simply

Products

18

ASLINKPOKAYOKE series

ASLINKPOKAYOKE series

Standard compact

◇Response: Lever switch

Instruction: Door opening/closing (metal arm horizontal) + LED (selection, combination)

*The above models are equipped with “H” holder as a standard.*When installing “H1” holder, add “-H1” at the end of the standard model.*When installing “SUS” holder, change the end of the standard model from “-P” to “-PS.”

◆ Door opening, closing (metal arm horizontal)+ LED indication (selection type, combination type)Interlocking type, independent type Lever switch type

32 BL227XB-RK04V-P2 1

ARW-04

ARW-04-RHARW-RH

34--

A027-HP28-5PA027-HP28-H1-5PA027-HP-SUS2

343434- A027-LES-01-5P

632 BL227XB-R2K04V-P2 2 632 BL227XB-RK06M-P2 3 632 BL227XB-R2K08M-P2 4 6

32 BL227XB-RK04VN-P2 1 632 BL227XB-R2K04VN-P2 2 632 BL227XB-RK06MN-P2 3 632 BL227XB-R2K08MN-P2 4 6

32 BL227XB-RK04VL-P2 1 632 BL227XB-R2K04VL-P2 2 632 BL227XB-RK06ML-P2 3 632 BL227XB-R2K08ML-P2 4 6

BL227XB-RK04V-PBL227XB-R2K04V-PBL227XB-RK06M-PBL227XB-R2K08M-P

BL227XB-RK04VN-PBL227XB-R2K04VN-PBL227XB-RK06MN-PBL227XB-R2K08MN-P

BL227XB-RK04VL-PBL227XB-R2K04VL-PBL227XB-RK06ML-PBL227XB-R2K08ML-P

◆ Door opening, closing (metal arm horizontal)+ LED indication (selection type, combination type)Interlocking type, independent type Pushbutton switch type

◆ Door opening, closing (metal arm horizontal)+ LED indication (selection type, combination type)Interlocking type, independent type Photoelectric downward re�ection

◇Response: Pushbutton switch

◇Detection: Photoelectric downward reflection type

φ28 pipe OpenStandby 19Motion 522Standby 19Motion 522Standby 19Motion 522Standby 19Motion 522

Lever switch

φ28 pipe OpenLever switch

φ28 pipe OpenLever switch

φ28 pipe OpenLever switch

Indication, instruction Installation

Number ofI/O points

Input Output Model

Response, detection

Page of Outline

DimensionalDrawings

Standardprice (¥)

Consumptioncurrent(mA)

I/Oside

Trans-mission

side

+ One colorselection type

+ Combinationtype

LED

+ Combinationtype

LED

+ One colorselection type

Pushbutton

Pushbutton

Pushbutton

Pushbutton

Indication, instruction Installation

Number ofI/O points

Input Output Model

Response, detection

Page of Outline

DimensionalDrawings

Standardprice (¥)

Open

Open

Open

Open

Consumptioncurrent(mA)

I/Oside

Standby 19Motion 522Standby 19Motion 522Standby 19Motion 522Standby 19Motion 522

Trans-mission

side

+ One colorselection type

+ Combinationtype

LED

+ Combinationtype

LED

+ One colorselection type

φ28 pipe

φ28 pipe

φ28 pipe

φ28 pipe

Downwardreflection

Downwardreflection

Downwardreflection

Downwardreflection

+ One colorselection type

+ Combinationtype

LED

+ Combinationtype

LED

+ One colorselection type

Indication, instruction Installation

Number ofI/O points

Input Output Model

Response, detection

Page of Outline

DimensionalDrawings

Standardprice (¥)

Open

Open

Open

Open

Consumptioncurrent(mA)

I/Oside

Standby 19Motion 522Standby 19Motion 522Standby 19Motion 522Standby 19Motion 522

Trans-mission

side

φ28 pipe

φ28 pipe

φ28 pipe

φ28 pipe

◆Address writer

◆ Option ・Common

Open

Open

Open

Open

Open

Open

Open*φ28 pipe installation holder is included with the POKAYOKE terminal (φ28 pipe installation type). Single part is an option for change of installation and repair.

Standard price (¥)Product speci�cations ModelInstallationPage of OutlineDimensional

Drawings

Standard price (¥)Product speci�cations ModelInstallationPage of OutlineDimensional

Drawings

Replacement rubber lever set (including cover, lever, ring respectively 5 pieces)

φ28 pipe

φ28 pipe

SUS pipe

Terminal

Non-contact typeAddress writer (general-purpose)

Non-contact typeAddress writer ARW-04 + Infrared ray remote head

Non-contact typeInfrared ray remote head for address writer

*The mark shows a made-to-order product.

[H] holder φ28 pipe installation holder lower tightening type (including 5 pieces)

[H1] holder

[SUS] holder

φ28 pipe installation holder back tightening type (including 5 pieces)

SUS pipe installation holder (including 1 piece)

Inde-pendentInde-pendent

Inter-lockedInter-locked

Inde-pendentInde-pendent

Inter-lockedInter-locked

Inde-pendentInde-pendent

Inter-lockedInter-locked

Inde-pendentInde-pendent

Inter-lockedInter-locked

Inde-pendentInde-pendent

Inter-lockedInter-locked

Inde-pendentInde-pendent

Inter-lockedInter-locked

Page 20: カタログ ASLINKPOKAYOKE 英語 PDF · POKA-YOKE is a global common word The POKAYOKE system comprising the AnyWire POKAYOKE terminal provides a solution to this problem simply

Products

19

ASLINKPOKAYOKE series

ASLINKPOKAYOKE series

◇Response: Lever switch

Instruction: Door opening/closing (plastic arm vertical) + LED (selection, combination)

*The above models are equipped with “H” holder as a standard.*When installing “H1” holder, add “-H1” at the end of the standard model.*When installing “SUS” holder, change the end of the standard model from “-P” to “-PS.”

◆ Door opening, closing (plastic arm vertical)+ LED indication (selection type, combination type)Interlocking type, independent type Lever switch type

33 BL227XB-F1K04V-P2 1

ARW-04

ARW-04-RHARW-RH

34--

A027-HP28-5PA027-HP28-H1-5PA027-HP-SUS2

343434- A027-LES-01-5P

633 BL227XB-F3K04V-P2 2 633 BL227XB-F1K06M-P2 3 633 BL227XB-F3K08M-P2 4 6

33 BL227XB-F1K04VN-P2 1 633 BL227XB-F3K04VN-P2 2 633 BL227XB-F1K06MN-P2 3 633 BL227XB-F3K08MN-P2 4 6

33 BL227XB-F1K04VL-P2 1 633 BL227XB-F3K04VL-P2 2 633 BL227XB-F1K06ML-P2 3 633 BL227XB-F3K08ML-P2 4 6

BL227XB-F1K04V-PBL227XB-F3K04V-PBL227XB-F1K06M-PBL227XB-F3K08M-P

BL227XB-F1K04VN-PBL227XB-F3K04VN-PBL227XB-F1K06MN-PBL227XB-F3K08MN-P

BL227XB-F1K04VL-PBL227XB-F3K04VL-PBL227XB-F1K06ML-PBL227XB-F3K08ML-P

Standard compact

◆ Door opening, closing (plastic arm vertical)+ LED indication (selection type, combination type)Interlocking type, independent type Pushbutton switch type

◆ Door opening, closing (plastic arm vertical)+ LED indication (selection type, combination type)Interlocking type, independent type Photoelectric downward re�ection

◇Response: Pushbutton switch

◇Detection: Photoelectric downward reflection type

φ28 pipe OpenStandby 19Motion 522Standby 19Motion 522Standby 19Motion 522Standby 19Motion 522

Lever switch

φ28 pipe OpenLever switch

φ28 pipe OpenLever switch

φ28 pipe OpenLever switch

Indication, instruction Installation

Number ofI/O points

Input Output Model

Response, detection

Page of Outline

DimensionalDrawings

Standardprice (¥)

Consumptioncurrent(mA)

I/Oside

Trans-mission

side

+ One colorselection type

+ Combinationtype

LED

+ Combinationtype

LED

+ One colorselection type

Pushbutton

Pushbutton

Pushbutton

Pushbutton

Indication, instruction Installation

Number ofI/O points

Input Output Model

Response, detection

Page of Outline

DimensionalDrawings

Standardprice (¥)

Open

Open

Open

Open

Consumptioncurrent(mA)

I/Oside

Standby 19Motion 522Standby 19Motion 522Standby 19Motion 522Standby 19Motion 522

Trans-mission

side

+ One colorselection type

+ Combinationtype

LED

+ Combinationtype

LED

+ One colorselection type

φ28 pipe

φ28 pipe

φ28 pipe

φ28 pipe

Downwardreflection

Downwardreflection

Downwardreflection

Downwardreflection

+ One colorselection type

+ Combinationtype

LED

+ Combinationtype

LED

+ One colorselection type

Indication, instruction Installation

Number ofI/O points

Input Output Model

Response, detection

Page of Outline

DimensionalDrawings

Standardprice (¥)

Open

Open

Open

Open

Consumptioncurrent(mA)

I/Oside

Standby 19Motion 522Standby 19Motion 522Standby 19Motion 522Standby 19Motion 522

Trans-mission

side

φ28 pipe

φ28 pipe

φ28 pipe

φ28 pipe

◆Address writer

◆ Option ・Common

Open

Open

Open

Open

Open

Open

Open*φ28 pipe installation holder is included with the POKAYOKE terminal (φ28 pipe installation type). Single part is an option for change of installation and repair.

Product speci�cations InstallationPage of OutlineDimensional

Drawings

Standard price (¥)Product speci�cations ModelInstallationPage of OutlineDimensional

Drawings

Replacement rubber lever set (including cover, lever, ring respectively 5 pieces)

φ28 pipe

φ28 pipe

SUS pipe

Non-contact typeAddress writer (general-purpose)

Non-contact typeAddress writer ARW-04 + Infrared ray remote head

Non-contact typeInfrared ray remote head for address writer

Standard price (¥)Model

*The mark shows a made-to-order product.

[H] holder φ28 pipe installation holder lower tightening type (including 5 pieces)

[H1] holder

[SUS] holder

φ28 pipe installation holder back tightening type (including 5 pieces)

SUS pipe installation holder (including 1 piece)

Terminal

Inde-pendentInde-pendent

Inter-lockedInter-locked

Inde-pendentInde-pendent

Inter-lockedInter-locked

Inde-pendentInde-pendent

Inter-lockedInter-locked

Inde-pendentInde-pendent

Inter-lockedInter-locked

Inde-pendentInde-pendent

Inter-lockedInter-locked

Inde-pendentInde-pendent

Inter-lockedInter-locked

Page 21: カタログ ASLINKPOKAYOKE 英語 PDF · POKA-YOKE is a global common word The POKAYOKE system comprising the AnyWire POKAYOKE terminal provides a solution to this problem simply

Products

20

ASLINKPOKAYOKE series

ASLINKPOKAYOKE series

◇Response: Lever switch

◇Response: Pushbutton switch

◇Detection: Photoelectric downward reflection type

Instruction: Door opening/closing (metal arm vertical) + 7-segment (variable four digit) + LED (selection, combination)

◆ Door opening, closing (metal arm vertical)+ 7-segment (variable four digit)+ LED indication (selection type, combination type)Interlocking type, independent type Pushbutton switch type

*The above models are equipped with “H” holder as a standard.*When installing “H1” holder, add “-H1” at the end of the standard model.*When installing “SUS” holder, change the end of the standard model from “-P” to “-PS.”

◆ Door opening, closing (metal arm vertical)+ 7-segment (variable four digit)+ LED indication (selection type, combination type)Interlocking type, independent type Lever switch type

33 BL227XB-FK7V4V-P2 1~17

ARW-04

ARW-04-RHARW-RH

34--

A027-HP28-5PA027-HP28-H1-5PA027-HP-SUS2

343434- A027-LES-01-5P

633 BL227XB-F2K7V4V-P2 2~18 633 BL227XB-FK7V4M-P2 3~19 633 BL227XB-F2K7V4M-P2 4~20

2 1~172 2~182 3~192 4~20

6

33 BL227XB-FK7V4VN-P6Pushbutton

33 BL227XB-F2K7V4VN-P6Pushbutton

33 BL227XB-FK7V4MN-P6Pushbutton

33 BL227XB-F2K7V4MN-P6Pushbutton

33 BL227XB-FK7V4VL-P6Downwardreflection

33 BL227XB-F2K7V4VL-P6Downwardreflection

33 BL227XB-FK7V4ML-P6Downwardreflection

33 BL227XB-F2K7V4ML-P6Downwardreflection

◆ Door opening, closing (metal arm vertical)+ 7-segment (variable four digit)+ LED indication (selection type, combination type)Interlocking type, independent type Photoelectric downward re�ection

2 1~172 2~182 3~192 4~20

BL227XB-FK7V4V-PBL227XB-F2K7V4V-PBL227XB-FK7V4M-PBL227XB-F2K7V4M-P

BL227XB-FK7V4VN-PBL227XB-F2K7V4VN-PBL227XB-FK7V4MN-PBL227XB-F2K7V4MN-P

BL227XB-FK7V4VL-PBL227XB-F2K7V4VL-PBL227XB-FK7V4ML-PBL227XB-F2K7V4ML-P

Standard compact

◆ Door opening/closing (plastic arm vertical)+ 7-segment (variable four digit)+ LED indication (selection type, combination type)Interlocking type/independent type Lever switch type

φ28 pipe OpenStandby 19Motion 580Standby 19Motion 580Standby 19Motion 580Standby 19Motion 580

Lever switch

φ28 pipe OpenLever switch

φ28 pipe OpenLever switch

φ28 pipe OpenLever switch

Indication, instruction Installation

Number ofI/O points

Input Output Model

Response, detection

Page of Outline

DimensionalDrawings

Standardprice (¥)

Consumptioncurrent(mA)

I/Oside

Trans-mission

side

+Combinationtype

LEDvariablefour digit

+Combinationtype

LEDvariablefour digit

+One colorselection type

variablefour digit

+One colorselection type

variablefour digit

φ28 pipe OpenStandby 19Motion 580Standby 19Motion 580Standby 19Motion 580Standby 19Motion 580

φ28 pipe Open

φ28 pipe Open

φ28 pipe Open

Indication, instruction Installation

Number ofI/O points

Input Output Model

Response, detection

Page of Outline

DimensionalDrawings

Standardprice (¥)

Consumptioncurrent(mA)

I/Oside

Trans-mission

side

+Combinationtype

LEDvariablefour digit

+Combinationtype

LEDvariablefour digit

+One colorselection type

variablefour digit

+One colorselection type

variablefour digit

φ28 pipe OpenStandby 19Motion 580Standby 19Motion 580Standby 19Motion 580Standby 19Motion 580

φ28 pipe Open

φ28 pipe Open

φ28 pipe Open

Indication, instruction Installation

Number ofI/O points

Input Output Model

Response, detection

Page of Outline

DimensionalDrawings

Standardprice (¥)

Consumptioncurrent(mA)

I/Oside

Trans-mission

side

+Combinationtype

LEDvariablefour digit

+Combinationtype

LEDvariablefour digit

+One colorselection type

variablefour digit

+One colorselection type

variablefour digit

◆Address writer

◆ Option ・Common

*The mark shows a made-to-order product.

Open

Open

Open

Open*φ28 pipe installation holder is included with the POKAYOKE terminal (φ28 pipe installation type). Single part is an option for change of installation and repair.

Product speci�cations InstallationPage of OutlineDimensional

Drawings

Replacement rubber lever set (including cover, lever, ring respectively 5 pieces)

φ28 pipe

φ28 pipe

SUS pipe

Standard price (¥)Model

[H] holder φ28 pipe installation holder lower tightening type (including 5 pieces)

[H1] holder

[SUS] holder

φ28 pipe installation holder back tightening type (including 5 pieces)

SUS pipe installation holder (including 1 piece)

Terminal

Open

Open

Open

Standard price (¥)Product speci�cations ModelInstallationPage of OutlineDimensional

Drawings

Non-contact typeAddress writer (general-purpose)

Non-contact typeAddress writer ARW-04 + Infrared ray remote head

Non-contact typeInfrared ray remote head for address writer

Inde-pendentInde-pendent

Inter-lockedInter-locked

Inde-pendentInde-pendent

Inter-lockedInter-locked

Inde-pendentInde-pendent

Inter-lockedInter-locked

Inde-pendentInde-pendent

Inter-lockedInter-locked

Inde-pendentInde-pendent

Inter-lockedInter-locked

Inde-pendentInde-pendent

Inter-lockedInter-locked

Page 22: カタログ ASLINKPOKAYOKE 英語 PDF · POKA-YOKE is a global common word The POKAYOKE system comprising the AnyWire POKAYOKE terminal provides a solution to this problem simply

Products

21

ASLINKPOKAYOKE series

ASLINKPOKAYOKE series

◇Response: Lever switch

◇Response: Pushbutton switch

◇Detection: Photoelectric downward reflection type

◆ Door opening, closing (metal arm horizontal)+ 7-segment (variable four digit)+ LED indication (selection type, combination type)Interlocking type, independent type Pushbutton switch type

◆ Door opening, closing (metal arm horizontal)+ 7-segment (variable four digit)+ LED indication (selection type, combination type)Interlocking type, independent type Lever switch type

◆ Door opening, closing (metal arm horizontal)+ 7-segment (variable four digit)+ LED indication (selection type, combination type)Interlocking type, independent type Photoelectric downward re�ection

Instruction: Door opening/closing (metal arm horizontal) + 7-segment (variable four digit) + LED (selection, combination)

*The above models are equipped with “H” holder as a standard.*When installing “H1” holder, add “-H1” at the end of the standard model.*When installing “SUS” holder, change the end of the standard model from “-P” to “-PS.”

33 BL227XB-RK7V4V-P

ARW-04

ARW-04-RHARW-RH

34--

A027-HP28-5PA027-HP28-H1-5PA027-HP-SUS2

343434- A027-LES-01-5P

633 BL227XB-R2K7V4V-P633 BL227XB-RK7V4M-P633 BL227XB-R2K7V4M-P6

33 BL227XB-RK7V4VN-P633 BL227XB-R2K7V4VN-P633 BL227XB-RK7V4MN-P633 BL227XB-R2K7V4MN-P6

33 BL227XB-RK7V4VL-P633 BL227XB-R2K7V4VL-P633 BL227XB-RK7V4ML-P633 BL227XB-R2K7V4ML-P6

2 1~172 2~182 3~192 4~20

2 1~172 2~182 3~192 4~20

2 1~172 2~182 3~192 4~20

BL227XB-RK7V4V-PBL227XB-R2K7V4V-PBL227XB-RK7V4M-PBL227XB-R2K7V4M-P

BL227XB-RK7V4VN-PBL227XB-R2K7V4VN-PBL227XB-RK7V4MN-PBL227XB-R2K7V4MN-P

BL227XB-RK7V4VL-PBL227XB-R2K7V4VL-PBL227XB-RK7V4ML-PBL227XB-R2K7V4ML-P

Standard compact

φ28 pipe OpenStandby 19Motion 580Standby 19Motion 580Standby 19Motion 580Standby 19Motion 580

Lever switch

φ28 pipe OpenLever switch

φ28 pipe OpenLever switch

φ28 pipe OpenLever switch

Indication, instruction Installation

Number ofI/O points

Input Output Model

Response, detection

Page of Outline

DimensionalDrawings

Standardprice (¥)

Consumptioncurrent(mA)

I/Oside

Trans-mission

side

+Combinationtype

LEDvariablefour digit

+Combinationtype

LEDvariablefour digit

+One colorselection type

variablefour digit

+variablefour digit

One colorselection type

Pushbutton

Pushbutton

Pushbutton

Pushbutton

φ28 pipe OpenStandby 19Motion 580Standby 19Motion 580Standby 19Motion 580Standby 19Motion 580

φ28 pipe Open

φ28 pipe Open

φ28 pipe Open

Indication, instruction Installation

Number ofI/O points

Input Output Model

Response, detection

Page of Outline

DimensionalDrawings

Standardprice (¥)

Consumptioncurrent(mA)

I/Oside

Trans-mission

side

+Combinationtype

LEDvariablefour digit

+Combinationtype

LEDvariablefour digit

+One colorselection type

variablefour digit

+One colorselection type

variablefour digit

Downwardreflection

Downwardreflection

Downwardreflection

Downwardreflection

φ28 pipe OpenStandby 19Motion 580Standby 19Motion 580Standby 19Motion 580Standby 19Motion 580

φ28 pipe Open

φ28 pipe Open

φ28 pipe Open

Indication, instruction Installation

Number ofI/O points

Input Output Model

Response, detection

Page of Outline

DimensionalDrawings

Standardprice (¥)

Consumptioncurrent(mA)

I/Oside

Trans-mission

side

+Combinationtype

LEDvariablefour digit

+Combinationtype

LEDvariablefour digit

+One colorselection type

variablefour digit

+variablefour digit

One colorselection type

◆Address writer

◆ Option ・Common

Open

Open

Open

Open

Open

Open

Open*φ28 pipe installation holder is included with the POKAYOKE terminal (φ28 pipe installation type). Single part is an option for change of installation and repair.

Product speci�cations InstallationPage of OutlineDimensional

Drawings

Standard price (¥)Product speci�cations ModelInstallationPage of OutlineDimensional

Drawings

Replacement rubber lever set (including cover, lever, ring respectively 5 pieces)

φ28 pipe

φ28 pipe

SUS pipe

Non-contact typeAddress writer (general-purpose)

Non-contact typeAddress writer ARW-04 + Infrared ray remote head

Non-contact typeInfrared ray remote head for address writer

Standard price (¥)Model

*The mark shows a made-to-order product.

[H] holder φ28 pipe installation holder lower tightening type (including 5 pieces)

[H1] holder

[SUS] holder

φ28 pipe installation holder back tightening type (including 5 pieces)

SUS pipe installation holder (including 1 piece)

Terminal

Inde-pendentInde-pendent

Inter-lockedInter-locked

Inde-pendentInde-pendent

Inter-lockedInter-locked

Inde-pendentInde-pendent

Inter-lockedInter-locked

Inde-pendentInde-pendent

Inter-lockedInter-locked

Inde-pendentInde-pendent

Inter-lockedInter-locked

Inde-pendentInde-pendent

Inter-lockedInter-locked

Page 23: カタログ ASLINKPOKAYOKE 英語 PDF · POKA-YOKE is a global common word The POKAYOKE system comprising the AnyWire POKAYOKE terminal provides a solution to this problem simply

Products

22

ASLINKPOKAYOKE series

ASLINKPOKAYOKE series

◇Response: Lever switch

◇Response: Pushbutton switch

◇Detection: Photoelectric downward reflection type

Instruction: Door opening/closing (plastic arm vertical) + 7-segment (variable four digit) + LED (selection, combination)

◆ Door opening, closing (plastic arm vertical)+ 7-segment (variable four digit)+ LED indication (selection type, combination type)Interlocking type, independent type Pushbutton switch type

*The above models are equipped with “H” holder as a standard.*When installing “H1” holder, add “-H1” at the end of the standard model.*When installing “SUS” holder, change the end of the standard model from “-P” to “-PS.”

◆Address writer

◆ Option ・Common

*The mark shows a made-to-order product.

◆ Door opening, closing (plastic arm vertical)+ 7-segment (variable four digit)+ LED indication (selection type, combination type)Interlocking type, independent type Lever switch type

33 BL227XB-F1K7V4V-P

ARW-04

ARW-04-RHARW-RH

34--

A027-HP28-5PA027-HP28-H1-5PA027-HP-SUS2

343434- A027-LES-01-5P

633 BL227XB-F3K7V4V-P633 BL227XB-F1K7V4M-P633 BL227XB-F3K7V4M-P6

33 BL227XB-F1K7V4VN-P633 BL227XB-F3K7V4VN-P633 BL227XB-F1K7V4MN-P633 BL227XB-F3K7V4MN-P6

33 BL227XB-F1K7V4VL-P633 BL227XB-F3K7V4VL-P633 BL227XB-F1K7V4ML-P633 BL227XB-F3K7V4ML-P6

◆ Door opening, closing (plastic arm vertical)+ 7-segment (variable four digit)+ LED indication (selection type, combination type)Interlocking type, independent type Photoelectric downward re�ection

2 1~172 2~182 3~192 4~20

2 1~172 2~182 3~192 4~20

2 1~172 2~182 3~192 4~20

BL227XB-F1K7V4V-PBL227XB-F3K7V4V-PBL227XB-F1K7V4M-PBL227XB-F3K7V4M-P

BL227XB-F1K7V4VN-PBL227XB-F3K7V4VN-PBL227XB-F1K7V4MN-PBL227XB-F3K7V4MN-P

BL227XB-F1K7V4VL-PBL227XB-F3K7V4VL-PBL227XB-F1K7V4ML-PBL227XB-F3K7V4ML-P

Standard compact

φ28 pipe OpenStandby 19Motion 580Standby 19Motion 580Standby 19Motion 580Standby 19Motion 580

Lever switch

φ28 pipe OpenLever switch

φ28 pipe OpenLever switch

φ28 pipe OpenLever switch

Indication, instruction Installation

Number ofI/O points

Input Output Model

Response, detection

Page of Outline

DimensionalDrawings

Standardprice (¥)

Consumptioncurrent(mA)

I/Oside

Trans-mission

side

+Combinationtype

LEDvariablefour digit

+Combinationtype

LEDvariablefour digit

+One colorselection type

variablefour digit

+variablefour digit

One colorselection type

Pushbutton

Pushbutton

Pushbutton

Pushbutton

φ28 pipe OpenStandby 19Motion 580Standby 19Motion 580Standby 19Motion 580Standby 19Motion 580

φ28 pipe Open

φ28 pipe Open

φ28 pipe Open

Indication, instruction Installation

Downwardreflection

Downwardreflection

Downwardreflection

Downwardreflection

φ28 pipe OpenStandby 19Motion 580Standby 19Motion 580Standby 19Motion 580Standby 19Motion 580

φ28 pipe Open

φ28 pipe Open

φ28 pipe Open

Indication, instruction Installation

Number ofI/O points

Input Output Model

Response, detection

Page of Outline

DimensionalDrawings

Standardprice (¥)

Consumptioncurrent(mA)

I/Oside

Trans-mission

side

+Combinationtype

LEDvariablefour digit

+Combinationtype

LEDvariablefour digit

+One colorselection type

variablefour digit

+variablefour digit

One colorselection type

Number ofI/O points

Input Output Model

Response, detection

Page of Outline

DimensionalDrawings

Standardprice (¥)

Consumptioncurrent(mA)

I/Oside

Trans-mission

side

+Combinationtype

LEDvariablefour digit

+Combinationtype

LEDvariablefour digit

+One colorselection type

variablefour digit

+One colorselection type

variablefour digit

Open

Open

Open

Open

Open

Open

Open*φ28 pipe installation holder is included with the POKAYOKE terminal (φ28 pipe installation type). Single part is an option for change of installation and repair.

Product speci�cations InstallationPage of OutlineDimensional

Drawings

Standard price (¥)Product speci�cations ModelInstallationPage of OutlineDimensional

Drawings

Replacement rubber lever set (including cover, lever, ring respectively 5 pieces)

φ28 pipe

φ28 pipe

SUS pipe

Non-contact typeAddress writer (general-purpose)

Non-contact typeAddress writer ARW-04 + Infrared ray remote head

Non-contact typeInfrared ray remote head for address writer

Standard price (¥)Model

[H] holder φ28 pipe installation holder lower tightening type (including 5 pieces)

[H1] holder

[SUS] holder

φ28 pipe installation holder back tightening type (including 5 pieces)

SUS pipe installation holder (including 1 piece)

Terminal

Inde-pendentInde-pendent

Inter-lockedInter-locked

Inde-pendentInde-pendent

Inter-lockedInter-locked

Inde-pendentInde-pendent

Inter-lockedInter-locked

Inde-pendentInde-pendent

Inter-lockedInter-locked

Inde-pendentInde-pendent

Inter-lockedInter-locked

Inde-pendentInde-pendent

Inter-lockedInter-locked

Page 24: カタログ ASLINKPOKAYOKE 英語 PDF · POKA-YOKE is a global common word The POKAYOKE system comprising the AnyWire POKAYOKE terminal provides a solution to this problem simply

Products

23

ASLINKPOKAYOKE series

ASLINKPOKAYOKE series

Standard type

Instruction: Door opening/closing + LED (selection) Response: Lever switch type, photoelectric downward reflection type

*The above models are equipped with “H” holder as a standard.*When installing “H1” holder, add “-H1” at the end of the standard model.*When installing “SUS” holder, change the end of the standard model from “-P” to “-PS.”

342 2 BL227XB-F04V-P

◆ Door opening, closing + LED indication (selection type)Independent type Lever switch type

◆ Door opening, closing + LED indication (selection type)Independent type Photoelectric downward re�ection type

◆Address writerARW-04

ARW-04-RHARW-RH

34--

A027-HP28-5PA027-HP28-H1-5PA027-HP-SUS2

343434- A027-LES-01-5P

6

□Arm lowering delay time

The arm is raised to the set angle by performing the door opening operations (output ON). Then, after performing the door closing operations (output OFF), it will be delayed for a certain period of time, and then the arm will be lowered to its original position.The delay time (0 to 10 seconds) from the door closing operations (output OFF) to descending to the original position can be set at 11 levels as shown in the table above.

012345678910

012345678910

Set value Delay time (Second)

□Arm raising angle

Arm raising angle can be set at seven stages up to approximately 180°. Adjustment can be made when the door collides with the shelf or work.Write No. of approximate position where you want to stop the door in angle setting mode of the address writer.*The angle is an approximate one, and the angle cannot be strictly designated.

approximately 25°

approximately 45°

approximately 73°

approximately 90°

approximately 130°approximately 155°

approximately 180°

342 2Downwardreflection BL227XB-F04VL-P6

BL227XB-F04V-P BL227XB-F04VL-P

“Address,” “Door arm raising and lowering angle” and “door arm lowering motion delay time” can be set by address writer.*“Door arm raising and lowering motion speed setting” cannot be performed.

+ One colorselection type φ28 pipe OpenStandby 19

Motion 522Lever switch

Indication, instruction Installation

Number ofI/O points

Input Output Model

Response, detection

Page of Outline

DimensionalDrawings

Standardprice (¥)

Consumptioncurrent(mA)

I/Oside

Trans-mission

side

+ One colorselection type φ28 pipe OpenStandby 19

Motion 522

Indication, instruction Installation

Number ofI/O points

Input Output Model

Response, detection

Page of Outline

DimensionalDrawings

Standardprice (¥)

Consumptioncurrent(mA)

I/Oside

Trans-mission

side

◆ Option ・Common

Open

Open

Open

Open*φ28 pipe installation holder is included with the POKAYOKE terminal (φ28 pipe installation type). Single part is an option for change of installation and repair.

Product speci�cations InstallationPage of OutlineDimensional

Drawings

Replacement rubber lever set (including cover, lever, ring respectively 5 pieces)

φ28 pipe

φ28 pipe

SUS pipe

Standard price (¥)Model

[H] holder φ28 pipe installation holder lower tightening type (including 5 pieces)

[H1] holder

[SUS] holder

φ28 pipe installation holder back tightening type (including 5 pieces)

SUS pipe installation holder (including 1 piece)

Terminal

*The mark shows a made-to-order product.

Open

Open

Open

Standard price (¥)Product speci�cations ModelInstallationPage of OutlineDimensional

Drawings

Non-contact typeAddress writer (general-purpose)

Non-contact typeAddress writer ARW-04 + Infrared ray remote head

Non-contact typeInfrared ray remote head for address writer

Inde-pendentInde-pendent

Inde-pendentInde-pendent

Page 25: カタログ ASLINKPOKAYOKE 英語 PDF · POKA-YOKE is a global common word The POKAYOKE system comprising the AnyWire POKAYOKE terminal provides a solution to this problem simply

Products

24

ASLINKPOKAYOKE series

ASLINKPOKAYOKE series

Indication: LED (selection, combination) Detection: Touch type (wire duct type, surface-emission type)

◆ LED indication (selection type, combination type)Touch type (wire duct type) 34Double-

sided tape1 1Touch B292XB-02VL

Remove a part on the shelf with the ejection lamp lit and touch the lamp with a finger for “ejection completion.”

This is a POKAYOKE module with the same shape as a wire duct with a width of 15mm. It can be installed on the side of a shelf board at a thickness of 15 mm or more, and installation work only requires attaching it with double-sided tape, making it very simple.

15㎜

◆Address writerARW-04

ARW-04-RHARW-RH

34--

◆ Option

34

34343434

A092-DMWire duct

Wire duct

Wire duct (1m)

A0102-CND-05Cable with double-ended connectors (0.3sq×2 core 5cm)

Wire duct A0102-CND-10Cable with double-ended connectors (0.3sq×2 core 10cm)

Wire duct A0102-CND-15Cable with double-ended connectors (0.3sq×2 core 15cm)

Wire duct A0102-CND-20Cable with double-ended connectors (0.3sq×2 core 20cm)

Open

34Wire duct A0102-CND-03Cable with double-ended connectors (0.3sq×2 core 3cm) Open

Open

Open

Open

34Wire duct A0102-CNE-20Transmission cable (0.3sq×2 core 20cm) Open

Open

Open

34Double-sided tape1 3Touch B292XB-06ML Open

L E DCombinationtype

One colorselection type

-6‐6

◆ LED indication (selection type)Touch type (surface-emission type)

*The mark shows a made-to-order product.

34Magnet1 1Touch BL2101XB-02VL-P OpenOne colorselection type 14.83

This is the most appropriate POKAYOKE terminal in the case that there are many small boxes like shelves for small parts and electronic parts.As it can be installed on a shelf board, etc., with a thickness of 15 mm or more, it can be utilized in various ways. The display method is LED indication, and the input method is touch type (photoelectric reflection type). It responds just by lightly tapping the body by hand.Since there are no moving parts, it is structured so that it does not easily break down.

Indication, instruction Installation

Number ofI/O points

Input Output Model

Response, detection

Page of Outline

DimensionalDrawings

Standardprice (¥)

Consumptioncurrent(mA)

I/Oside

Trans-mission

side

Product speci�cations InstallationPage of OutlineDimensional

Drawings Standard price (¥)Model

Indication, instruction Installation

Number ofI/O points

Input Output Model

Response, detection

Page of Outline

DimensionalDrawings

Standardprice (¥)

Consumptioncurrent(mA)

I/Oside

Trans-mission

side

Open

Open

Open

Standard price (¥)Product speci�cations ModelInstallationPage of OutlineDimensional

Drawings

Non-contact typeAddress writer (general-purpose)

Non-contact typeAddress writer ARW-04 + Infrared ray remote head

Non-contact typeInfrared ray remote head for address writer

Page 26: カタログ ASLINKPOKAYOKE 英語 PDF · POKA-YOKE is a global common word The POKAYOKE system comprising the AnyWire POKAYOKE terminal provides a solution to this problem simply

Products

25

ASLINKPOKAYOKE series

ASLINKPOKAYOKE series

Terminator (terminator for AnyWireASLINK)

FK4-125-100LP4-WR-10PLP4-OR-10PLP-TOOL

ANF-0192x53x41

BT044x24.5x12

◆Terminator (Waveform shaping module)

OpenTransmission wave shaping module (with polarity) cable connection (attachment holder included)

StandardModelDimensionsProduct speci�cations price(¥)(mm)

Filter (filter for AnyWireASLINK)

◆Filter

Standard

OpenFilter for 24V lineprice(¥)ModelDimensions

(mm)Product speci�cations

*If any of the side-by-side lines of DP, DV, 24V and 0V exceeds the total length of 50m in a power supply system to be supplied, insert this filter.*Sufficiently confirm the specifications reffering to the Product Guide (Product instruction manual).

Accessories

◆AnyWire Cable/Connector (AnyWire transmission cable & connector)

LP connector (10 connectors included)*Crimp type link connector (Allowable current 5A)

Open

Crimping tool for LP connector

Flat cable (100m winding)(Conductor resistance 0.015Ω/m·Allowable current 12.7A)

Standard price (¥)Product speci�cations ModelDetails

For cabtire cable (Coating outer diameter φ2.1 to 2.4mm Cover: Orange Body: Black)

OpenFor 4-core �at cable (1.25sq) (coating outer diameter φ2.54mm Cover: White Body: Red) Pin protector type

Open

OpenCrimping tool dedicated to LP connector (The connector can be crimped by pliers, etc., however, a dedicated tool is recommended)

Body colorRed: for wire diameter size 1.25sqBlack: for wire diameter size 0.75sq 4-

pol

e

4-core �at cable (AWG16 (1.25sq) × 4-core Insulating coating outer diameter φ2.5±0.1mm)

◇Flat cable appearance photo

4-core �at cableAWG16 (1.25sq)×4-core

(DN:DP:0V:24V from the left)

When using in combination with the dedicated �at cable and LP connector (link connector), connect wires so that the black electric wire (DN line) is on the hinge side (No. 1) of the connector body as shown in the photo.

Page 27: カタログ ASLINKPOKAYOKE 英語 PDF · POKA-YOKE is a global common word The POKAYOKE system comprising the AnyWire POKAYOKE terminal provides a solution to this problem simply

Products

26

ASLINKPOKAYOKE series

ASLINKPOKAYOKE series

< MEMO >

Page 28: カタログ ASLINKPOKAYOKE 英語 PDF · POKA-YOKE is a global common word The POKAYOKE system comprising the AnyWire POKAYOKE terminal provides a solution to this problem simply

Products

27

ASLINKPOKAYOKE series

ASLINKPOKAYOKE series

Master Units

◆Interface for each MELSEC series◆Bridge unit for CC-Link/CC-Link IE Field

LJ51AW12AL*Sold by Mitsubishi Electric Corporation

MELSEC-LAnyWireASLINKMaster unit

FX3U-128ASL-M*Sold by Mitsubishi Electric Corporation

MELSEC-FAnyWireASLINKMaster block

NZ2AW1C2AL*Sold by Mitsubishi Electric Corporation

CC-Link-AnyWireASLINKBridge unit

L02SCPU, L02SCPU-P, L02CPU, L02CPU-P, L06CPU, L06CPU-P, L26CPU, L26CPU-P, L26CPU-BT, L26CPU-PBT, LJ72GF15-T2

32 points (I/O allotment: Interior 32 points)

Mass90.0(H)x28.5(W)x104.5(D) 200g

32 points (I/O allotment: Interior 32 points)

Mass 200g98.0(H)x27.4(W)x100.0(D)

Circuit: (supplied from L bus side) Voltage +5[V]±5% Current 0.2[A] max.

Transmission line driver: (Supplied to front panel terminal)

Voltage 24[V] DC +15 to -10% (21.6 to 27.6[V] DC) Ripple 0.5[V]p-p max.

Current 0.1[A] (when 128 slave units are connected, not including load current)

Circuit: (supplied from Q bus side) Voltage +5[V]±5% Current 0.2[A] max.

Transmission line driver: (Supplied to front panel terminal)

Voltage 24[V] DC +15 to -10% (21.6 to 27.6[V] DC) Ripple 0.5[V]p-p max.

Current 0.1[A] (when 128 slave units are connected, not including load current)

Voltage 24[V] DC +15 to -10% (21.6 to 27.6[V] DC)

Current 0.2[A] (when 128 slave units are connected, not including load current)Transmission line driver: (Supplied to front panel terminal)

CC-Link Ver. 1.10, Ver. 2.00 (Switched by setting)

Voltage 24[V] DC +15 to -10% (21.6 to 27.6[V] DC)

Current 0.3[A] (when 128 slave units are connected, not including load current)Transmission line driver: (Supplied to front panel terminal)

Corresponding CC-Link IE Field

FX3G (Ver.1.00~), FX3U (Ver.2.20~), FX3GC (Ver.1.40~), FX3UC (Ver.2.20~)

Q06CCPU-V-H01,

Q00JCPU,Q00CPU,Q01CPU,Q02CPU,Q02HCPU,Q06HCPU,

Q25HCPU,

Q02PHCPU,Q06PHCPU,Q12PHCPU,Q25PHCPU,Q12PRHCPU,Q25PRHCPU,Q00UJCPU,Q00UCPU,

Q01UCPU,Q02UCPU,Q03UDCPU,Q04UDHCPU,

Q10UDHCPU,Q13UDHCPU,Q20UDHCPU,

Q26UDHCPU,Q03UDECPU,Q04UDEHCPU,

Q10UDEHCPU, Q13UDEHCPU, Q20UDEHCPU,Q26UDEHCPU,

Q50UDEHCPU, Q100UDEHCPU,

Q04UDVCPU,

Q12HCPU,

Q06UDHCPU,Q06UDEHCPU,

Q03UDVCPU,

Q06UDVCPU,

Q26UDVCPU, Q13UDVCPU,

Q06CCPU-V,Q06CCPU-V-B, Q12DCCPU-V,Q24DHCCPU-V

QJ51AW12AL*Sold by Mitsubishi Electric Corporation

MELSEC-QAnyWireASLINKMaster unit

Voltage +5[V] Current 0.13[A] max.

Transmission line driver: (Supplied to front panel terminal)

Voltage 24[V] DC +15 to -10% (21.6 to 27.6[V] DC) Ripple 0.5[V]p-p max.

Current 0.1[A] (when 128 slave units are connected, not including load current)

Circuit: (Supplied from additionally installed cable side)

*Sold by Mitsubishi Electric Corporation

NZ2AW1GFAL

CC-Link IE Field-AnyWireASLINKBridge unit

OpenFieldBus sideSupport protocol

Corresponding CPU*1

Power supply

Number of occupied input/output points

Outer dimensions (mm)

Number of occupied input/output points

Corresponding CPU*1

Corresponding CPU*1

Outer dimensions (mm)

Set to Ver. 1.10 (1 station, 2 stations, 3 stations, 4 stations selected) or Ver. 2.00 (4 stations �xed, expanded 2 times setting)

Mass 200g105.5(H)x43(W)x86(D)

Number of occupied stationsOuter dimensions (mm)

Mass 200g105.5(H)x43(W)x86(D)Outer dimensions (mm)

8 points

Mass 200g90.0(H)x43.0(W)x95.5(D)

Number of occupied input/output points

Outer dimensions (mm)

Power supply

Power supply

Power supply

32 points (I/O allotment: Interior 32 points)

Mass 200g106.0(H)×27.8(W)×124(D)

Circuit: (supplied from iQ -R bus side)

Transmission line driver: (Supplied to front panel terminal)

R04CPU,R08CPU,R16CPU,R32CPU,

R120CPU,R04ENCPU,

R16ENCPU,

R32ENCPU,R120ENCPU,R08PCPU,R16PCPU,

R32PCPU,R120PCPU,R08SFCPU-SET,R16SFCPU-SET,

R32SFCPU-SET,R120SFCPU-SET,R12CCPU-VR08ENCPU,

RJ51AW12AL*Sold by Mitsubishi Electric Corporation

MELSEC iQ-RAnyWireASLINKMaster unit

Number of occupied input/output points

Corresponding CPU*1

Outer dimensions (mm)

Power supply

OpenFieldBus sideSupport protocol

Power supply

Voltage +5[V]±5% Current 0.2[A] max.

Voltage 24[V] DC +15 to -10% (21.6 to 27.6[V] DC) Ripple 0.5[V]p-p max.

Current 0.1[A] (when 128 slave units are connected, not including load current)

*1 Con�rm details for the corresponding CPU and other limitations with the AnyWireASLINK master unit users manual of each product published by Mitsubishi Electric Corporation.

FX5-ASL-M*Sold by Mitsubishi Electric Corporation

MELSEC iQ-FAnyWireASLINKMaster unitFX5-ASL-M

LINK

SET

ALM

POWERRUN

ERROR

24V0V

24V0V

AnyWire

IN

OUT

(LG)

DPDN

SET

FX5U, FX5UCVoltage +5[V] Current 0.2[A] max.

Voltage 24[V] DC +15 to -10% (21.6 to 27.6[V] DC) Ripple 0.5[V]p-p max.

Current 0.1[A] (when 128 slave units are connected, not including load current)

Transmission line driver: (Supplied to front panel terminal)

Circuit: (Supplied from additionally installed cable side)

Corresponding CPU*1

8 points

Mass 200g90.0(H)x40.0(W)x97.3(D)

Number of occupied input/output points

Outer dimensions (mm)

Power supply

Page 29: カタログ ASLINKPOKAYOKE 英語 PDF · POKA-YOKE is a global common word The POKAYOKE system comprising the AnyWire POKAYOKE terminal provides a solution to this problem simply

Products

28

ASLINKPOKAYOKE series

ASLINKPOKAYOKE series

Master Units

AnyWireASLINKDeviceNetGateway*2

B2G78-D1105.8(H)×43.0(W)×86.0(D)Outer dimensions (mm)

Power supply

AnyWireASLINKPROFIBUSGateway*2

B2G78-PB1105.8(H)×43.0(W)×86.0(D)

Transmission line driver: (Supplied to front panel terminal)

Voltage 24[V] DC +15 to -10% (21.6 to 27.6[V] DC) Ripple 0.5[V]p-p max.

Current 0.15[A] (when 128 slave units are connected, not including load current)

Outer dimensions (mm)

Power supply

*2 Contact our sales division for digital link function relationship of B2G78-D1, B2G78-PB1 and B2G78-E1.

AnyWireASLINKEthernetGateway*2

*3 Contact our sales division for digital link function relationship of B2P8-E01.

Mass 190g

Standard price (¥)

Standard price (¥)

Standard price (¥)

Open

Open

Mass 190g

Mass 190g

Open105.8(H)×43.0(W)×86.0(D)

Transmission line driver: (Supplied to front panel terminal)

Voltage 24[V] DC +15 to -10% (21.6 to 27.6[V] DC) Ripple 0.5[V]p-p max.

Current 0.15[A] (when 128 slave units are connected, not including load current)

Outer dimensions (mm)

Power supply

OpenFieldBus sideSupport protocol

OpenFieldBus sideSupport protocol

◆Master interface for PC bus

◆Gateway for OpenFieldBus/EtherNet

Master I/F for AnyWireASLINK PCI Express*3

B2P8-E01 67.9(W)x167.6(D) (Master I/F board only)

Transmission line driver:(Supply to connector terminals on the bracket face.)

Voltage 24[V] DC +15 to -10% (21.6 to 27.6[V] DC) Ripple 0.5[V] p-p max.

Current 0.1[A] (when 128 slave units are connected, not including load current)

Outer dimensions (mm)

Power supply

Standard price (¥) OpenMass 65g

Compatible with PCI Express 2.0 (Gen2) ×1 lane (Available by ×1, ×4, ×8, ×16 slot)Compatible with low pro�le (brackets for low pro�le and standard pro�le are attached.)

PCI Express-side specifications

PROFIBUSOpenFieldBus sideSupport protocol

012345 67 89 ABCDEF

Transmission line driver: (Supplied to front panel terminal)

Voltage 24[V] DC +15 to -10% (21.6 to 27.6[V] DC) Ripple 0.5[V]p-p max.

Current 0.15[A] (when 128 slave units are connected, not including load current)

DeviceNet

MC protocolEtherNet/IP

Modbus/TCP

EtherIP command: Responding to List Service, List ldentity, Register Session, Send RR Data, SendUnit dataCIP command: Responding to Get Attribute All, Get Attribute Single, Send Unit DataResponse command(0x02) Read Discrete Inputs: BIT IN, (0x01) Read Coiles: BIT OUT, (0x05) Write Single Coile: BIT OUT(0x04) Read Input Registers: WORD IN, (0x03) Read Holding Registers: WORD OUT(0x06) Write Single Register: WORD OUT, (0x10) Read Multiple Registers: WORD OUT

(When mounting a bracket for low pro�le)

B2G78-E1

*4 Contact our sales division for digital link function relationship of BR27-01.

◆Resend Unit

AnyWireASLINKResend unit *4

BR27-01 40.0(H)×100.0(W)×48.0(D)

Transmission line driver:(Supplied to connector terminal)

Outer dimensions (mm)

Power supply

Open66g

Transmission between input terminal and output terminal with the same address setting is conducted.Ex) When an input is made into the input terminal with address of 50, the output signal is mechanically transmitted to the output terminal with address No. 50.

Product specifications

*5 Contact our sales division for digital link function relationship of AB27-AL.

◆Bridge for AnyWire DB A20

Bridge for AnyWireASLINK DB A20 series*5

AB27-AL 40.2(H)×100.0(W)×40.0(D)

Transmission line driver:(Supplied to connector terminal)

Outer dimensions (mm)

Power supply

Open69g

AnyWireASLINK DB A20 series (AnyWire BUS dedicated protocol)(Usable by 31.3kHz setting, only one unit is connectable)

Connection specifications

IN32/OUT32

IN64/OUT64

IN128/OUT128

IN256/OUT256

FG 24V 0V D G DP DN

FG 24V 0V D G DP DN

RDY LINK LINK SET ALM

ASLINK BridgeAB27-AL

SET

Voltage 24[V] DC +15 to -10% (21.6 to 27.6[V] DC) Ripple 0.5[V] p-p max.

Current 0.1[A] (when 128 slave units are connected, not including load current)

Voltage 24[V] DC +15 to -10% (21.6 to 27.6[V] DC) Ripple 0.5[V] p-p max.

Current 0.1[A] (when 128 slave units are connected, not including load current)

Standard price (¥)Mass

Standard price (¥)Mass

Page 30: カタログ ASLINKPOKAYOKE 英語 PDF · POKA-YOKE is a global common word The POKAYOKE system comprising the AnyWire POKAYOKE terminal provides a solution to this problem simply

Address Setting

29 ASLINKPOKAYOKE series

ASLINKPOKAYOKE series

Address setting by address writer

Address setting method

Structure of address

Set an address by infrared ray by directing

the address writer to the setting port.

Address setting method for the AnyWire POKAYOKE terminal is to use an address writerto read and write address in a non-contact state.

AnyWire POKAYOKE terminals inform of the existence of terminals to a controller on the upper order by setting the head address of individual terminals. The address is represented by a decimal number, and can be set in units of 1 bit.*Maximum number of points varies with the system configuration. Contact us for details.

Examples of setting in the case that some types of POKAYOKE terminals are combined are shown below.

Number of input and output points

Number of occupied pointsNumber of inputs or outputs,

whichever is greater

Head address setting

2 3 5 1

0 2 5 10

<Example of setting>LINK IN R/WLINK IN R/W

ARW-RH

BL2

27PB

-T07

P06M

-PPO

KAYO

KE T

erm

inal

BL227XB

-T07P06M-C

POKAYO

KE Terminal

Approx.20°

Light emittingand receiving part

Setting port

LINK IN R/W

Input 2 point

Output 2 pointInput 1 point

Output 3 point

Input 1 point

Output 5 point

Input 1 pointOutput 1 point [Output is common to light

emission and reception]

The address of the �rst address is “0.” Then, the address of the next terminal is, as a rule,

“address set value of immediately previous terminal” + “number of occupied points of immediately previous terminal (Number of inputs or outputs, whichever is greater),”

and values for the number of occupied points are sequentially added. As the number of occupied points differs with each terminal, refer to and confirm by the introduction page of each product.

It is not necessary that the address set values are in connecting order. If addresses are set without duplication even when the connecting orders are exchanged by remodeling or expansion, operation can be made. And it is not necessary to always set without a margin. If there are number of points to spare and expansion, etc., is expected in the future, skip some addresses when setting.

Address writer ARW-04

When i t is di f f icul t to hold ARW-04 at narrow locations, use an optional remote head. (Model: ARW-RH)

■Name of each part

ARW-04

Ring for strap

Position of light emitting andreceiving part (yellow part)

POWER indication lamp

Comment indication part (7-segment 6 digits)

RH (Remote head)

Connection connector (Side)

POWER (CLEAR) buttonR button

DOWN button

SELECT button

UP buttonL button

SET button

Operation modeindication lamp

■Reference of approach when address is set and confirmed(Image of operation)

Setting port

*Example: ARW-04 and POKAYOKE terminal o f p h o t o e l e c t r i c transmission type

Light emitting and receiving part

Up to approx. 20mm

Setting port

Approx.20°

When setting an address, be careful of the following.

◇Perform operations of address setting by the address writer with transmission signal and power fed to the POKAYOKE terminal, and reset the power after completion of setting to reflect the setting.

When any change is made in direct mode, the changed content is immediately reflected, therefore, unexpected motion may be caused, and this is very dangerous.

◇Refer to and confirm by the manual for details.

Page 31: カタログ ASLINKPOKAYOKE 英語 PDF · POKA-YOKE is a global common word The POKAYOKE system comprising the AnyWire POKAYOKE terminal provides a solution to this problem simply

Products

30

ASLINKPOKAYOKE series

ASLINKPOKAYOKE series

< MEMO >

Page 32: カタログ ASLINKPOKAYOKE 英語 PDF · POKA-YOKE is a global common word The POKAYOKE system comprising the AnyWire POKAYOKE terminal provides a solution to this problem simply

Dimensions

31  

ASLINKPOKAYOKE series

ASLINKPOKAYOKE series

*Refer to page 34 for Outline Dimensional Drawings of φ28 pipe installation holder and SUS pipe installation holder excluding those for transmission type.

Hexagon socket head cap screwM6 × 15 (Included)Tightening torque1.5 ~ 2 N·m

Commercially available round pipeφ28.0

Hexagon socket head cap screw tightening hole

UL 202764-core × No.23AWGφ4.6 Gray

Commercially available round pipeφ28.0

Hexagon socket head cap screw tightening hole

UL 202764-core × No.23AWGφ4.6 Gray

Hexagon socket head cap screwM6 × 15 (Included)Tightening torque1.5 ~ 2 N·m

Hexagon socket head cap screwM6 × 15 (Included)Tightening torque1.5 ~ 2 N·m

Commercially available round pipeφ28.0

Compatible with M4 hexagon nut

Compatible with M4 hexagon nut

Compatible with M4 hexagon nut

Compatible with M4 hexagon nut

Hexagon socket head cap screwM6 × 15 (Included)Tightening torque1.5 ~ 2 N·m

Commercially available round pipeφ28.0

BL227XB-K0□□-P

(150)

4=24V3=0V

60

36

2=DP1=DN

24.1

25 18 (18)

18 9

30

7.5

51.6

66

4=24V3=0V2=DP1=DN

BL227XB-K0□□N-P /BL227XB-K0□□L-P

60

24.136

18 9

3051.6

25 18 (18)

(150)

BL227PB-T14P0□□-P / BL227XB-T14P0□□-CBL227PB-T07P0□□-P / BL227XB-T07P0□□-C

A027-T14PCA027-T07PC

62

47

3

162616

8.41.2

27

15.5

2-R2.25

R1

70

3-φ4

R5.5

56 2828

3

13.513.5

4

8.4

15.5

1.2

132

5-φ6

27

2-R2.25

94

140

R5.5

A027-T07PHP28-H1 A027-T14PHP28-H1

73

62

11

33

40.3

2-φ3.5

143

132

40

40

11 40.3

33

2-φ3.5

(300)

62 52

70

8

3

2427

R2

1=DN2=DP3=0V4=24V

(300)

62

52 70

8

3

2427

R2

1=DN2=DP3=0V4=24VBL227PB-T07P02V-P BL227XB-T07P02V-C

3

24

27

R2

122

(300)

140

132

1=DN2=DP3=0V4=24VBL227PB-T14P02V-P BL227XB-T14P02V-C

8

3

24

27

R2

122

(300)

140

132

1=DN2=DP3=0V4=24V

8

(Operation stroke: 3mm)*1

4

*1 This operation stroke is only applicable to BL227XB-K0□□N-P.

Unit: mm

Outline Dimensional Drawings

Page 33: カタログ ASLINKPOKAYOKE 英語 PDF · POKA-YOKE is a global common word The POKAYOKE system comprising the AnyWire POKAYOKE terminal provides a solution to this problem simply

Dimensions

32

ASLINKPOKAYOKE series

ASLINKPOKAYOKE series

Hexagon socket head cap screw tightening hole

(Operation stroke: 3mm)*1

UL 202764-core × No.23AWGφ4.6 Gray

Hexagon socket head cap screw tightening hole

Hexagon socket head cap screwM6 × 15 (Included)Tightening torque1.5 ~ 2 N·m

Commercially available round pipeφ28.0

Commercially available round pipeφ28.0

Hexagon socket head cap screw tightening hole

Hexagon socket head cap screw tightening hole

(Operation stroke: 3mm)*1

UL 202764-core × No.23AWGφ4.6 Gray

UL 202764-core × No.23AWGφ4.6 Gray

Hexagon socket head cap screwM6 × 15 (Included)Tightening torque1.5 ~ 2 N·m

Hexagon socket head cap screwM6 × 15 (Included)Tightening torque1.5 ~ 2 N·m

Commercially available round pipeφ28.0

Hexagon socket head cap screw tightening hole

UL 202764-core × No.23AWGφ4.6 Gray

Hexagon socket head cap screwM6 × 15 (Included)Tightening torque1.5 ~ 2 N·m

Commercially available round pipeφ28.0

M4

tap

M4

tap

Hexagon socket head cap screw tightening hole

UL 202764-core × No.23AWGφ4.6 Gray

Hexagon socket head cap screwM6 × 15 (Included)Tightening torque1.5 ~ 2 N·m

Commercially available round pipeφ28.0

Hexagon socket head cap screw tightening hole

UL 202764-core × No.23AWGφ4.6 Gray

Hexagon socket head cap screwM6 × 15 (Included)Tightening torque 1.5 ~ 2 N·m

Hexagon socket head cap screw tightening hole

UL 202764-core × No.23AWGφ4.6 Gray

Hexagon socket head cap screwM6 × 15 (Included)Tightening torque 1.5 ~ 2 N·m

M4 tap

Commercially available round pipeφ28.0

M4 tap

Commercially available round pipeφ28.0

UL 202764-core × No.23AWGφ4.6 Gray

Hexagon socket head cap screwM6 × 15 (Included)Tightening torque1.5 ~ 2 N·m

Commercially available round pipeφ28.0

7.5

66

1=DN2=DP3=0V4=24V

BL227XB-K71□-P

4

25 18 (18)

(150)

18

36

924.1

51.6

30

60

1=DN2=DP3=0V4=24V

(150) 4

25 18 (18)

18

36

9

24.1

51.6

30

60

BL227XB-K71□N-P / BL227XB-K71□L-P

4=24V3=0V2=DP1=DN

BL227XB-K72□N-P / BL227XB-K72□L-P

60

24.136

18 9

3051.6

25 18

4

(18)

(150)

BL227XB-K72□-P

(150)

4=24V3=0V

36

2=DP1=DN

24.1

25 18 (18)

18 9

30

7.5

51.6

66

BL227XB-FK0□□-P /BL227XB-F2K0□□-P

4=24V3=0V2=DP1=DN

(18) 53.8 (64.5)

(9.9)

(2.4)

(150)

6.2

(84.5)73

22

40

36

(106)

8.5

54

BL227XB-FK0□□N-P / BL227XB-FK0□□L-P / BL227XB-F2K0□□N-P / BL227XB-F2K0□□L-P

4=24V3=0V2=DP1=DN

(18) 53.8 (64.5)

(9.9)

(2.4)

(150)

6.2

(84.5)73

22

40

36

(106)

8.5

54

BL227XB-R□K0□□-P

4=24V3=0V2=DP1=DN

(150)

62.5

6.2

84

11 73

36

66.5

8.5

35.8 (18.5)

54

BL227XB-R□K0□□N-P /BL227XB-R□K0□□L-P

4=24V3=0V2=DP1=DN

(150)

62.5

6.2

84

11 73

36

8.5

35.8 (18.5)

54

40

8

40

8

*1 This operation stroke is only applicable to BL227XB-K71□N-P.

*1 This operation stroke is only applicable to BL227XB-K72□N-P.

*Refer to page 34 for Outline Dimensional Drawings of φ28 pipe installation holder and SUS pipe installation holder.

Unit: mm

Outline Dimensional Drawings

Page 34: カタログ ASLINKPOKAYOKE 英語 PDF · POKA-YOKE is a global common word The POKAYOKE system comprising the AnyWire POKAYOKE terminal provides a solution to this problem simply

Dimensions

33  

ASLINKPOKAYOKE series

ASLINKPOKAYOKE series

*Refer to page 34 for Outline Dimensional Drawings of φ28 pipe installation holder and SUS pipe installation holder.

Commercially available round pipeφ28.0

Hexagon socket head cap screw tightening holeUL 20276

4-core × No.23AWGφ4.6 Gray

Hexagon socket head cap screwM6 × 15 (Included)Tightening torque1.5 ~ 2 N·m

4-φ2.5 hole

Commercially available round pipeφ28.0

Hexagon socket head cap screw tightening holeUL 20276

4-core × No.23AWGφ4.6 Gray

Hexagon socket head cap screwM6 × 15 (Included)Tightening torque1.5 ~ 2 N·m

4-φ2.5 hole

Hexagon socket head cap screw tightening hole

UL 202764-core × No.23AWGφ4.6 Gray

Hexagon socket head cap screwM6 × 15 (Included)Tightening torque1.5 ~ 2 N·m

Commercially available round pipeφ28.0

Commercially available round pipeφ28.0

M4

tap

M4

tap

M4 tap

Hexagon socket head cap screw tightening hole

Hexagon socket head cap screw tightening hole

UL 202764-core × No.23AWGφ4.6 Gray

UL 202764-core × No.23AWGφ4.6 Gray

Hexagon socket head cap screwM6 × 15 (Included)Tightening torque1.5 ~ 2 N·m

Commercially available round pipeφ28.0

Hexagon socket head cap screwM6 × 15 (Included)Tightening torque1.5 ~ 2 N·m

Hexagon socket head cap screw tightening hole

UL 202764-core × No.23AWGφ4.6 Gray

Hexagon socket head cap screwM6 × 15 (Included)Tightening torque1.5 ~ 2 N·m

Commercially available round pipeφ28.0

Commercially available round pipeφ28.0

M4 tap

Hexagon socket head cap screw tightening hole

UL 202764-core × No.23AWGφ4.6 Gray

Hexagon socket head cap screwM6 × 15 (Included)Tightening torque1.5 ~ 2 N·m

4-φ2.5 hole

Commercially available round pipeφ28.0

Hexagon socket head cap screw tightening hole

UL 202764-core × No.23AWGφ4.6 Gray

Hexagon socket head cap screwM6 × 15 (Included)Tightening torque1.5 ~ 2 N·m

4-φ2.5 hole

BL227XB-F1K0□□-P /BL227XB-F3K0□□-P

4=24V3=0V2=DP1=DN

(84.5)73

36

(108)

40

67

18

86083

54

102.6

6

(3.3)

(150)

(18) 53.8 (64.5)

(10.8

BL227XB-F1K0□□N-P / BL227XB-F1K0□□L-P / BL227XB-F3K0□□N-P / BL227XB-F3K0□□L-P

4=24V3=0V2=DP1=DN

(84.5)73

36

(108)

40

67

18

86083

54

6

(3.3)

(150)

(18) 53.8 (64.5)

(10.8

BL227XB-FK7V4□-P /BL227XB-F2K7V4□-P

BL227XB-R□K7V4□-P

BL227XB-F1K7V4□-P /BL227XB-F3K7V4□-P

4=24V3=0V2=DP1=DN

4=24V3=0V2=DP1=DN

4=24V3=0V2=DP1=DN

(18) 53.8 (64.5)

(9.9

(2.4)

(150)

(150)

6.2

(84.5)73

22

40

36

(106)

8.5

54

BL227XB-FK7V4□N-P /BL227XB-FK7V4□L-P /BL227XB-F2K7V4□N-P /BL227XB-F2K7V4□L-P

4=24V3=0V2=DP1=DN

(18) 53.8 (64.5)

(9.9

(2.4)

(150)

6.2

(84.5)73

22

40

36

(106)

8.5

54

40

8

40

8

62.5

6.2

84

11 73

36

66.5

8.5

35.8 (18.5)

54

BL227XB-R□K7V4□N-P /BL227XB-R□K7V4□L-P

4=24V3=0V2=DP1=DN

(150) 62.5

6.2

84

11 73

36

8.5

35.8 (18.5)

54

(84.5)73

36

(108)

40

67

18

86083

54

102.6

6

(3.3)

(150)

(18) 53.8 (64.5)

(10.8

BL227XB-F1K7V4□N-P /BL227XB-F1K7V4□L-P /BL227XB-F3K7V4□N-P /BL227XB-F3K7V4□L-P

4=24V3=0V2=DP1=DN

(84.5)73

36

(108)

40

67

18

86083

54

6

(3.3)

(150)

(18) 53.8 (64.5)

(10.8

Unit: mm

Outline Dimensional Drawings

Page 35: カタログ ASLINKPOKAYOKE 英語 PDF · POKA-YOKE is a global common word The POKAYOKE system comprising the AnyWire POKAYOKE terminal provides a solution to this problem simply

Dimensions

34

ASLINKPOKAYOKE series

ASLINKPOKAYOKE series

Hexagon socket head cap screw tightening hole

HKV4-core × AWG18

M4

tap

Hexagon socket head cap screwM6 × 15 (Included)Tightening torque1.5 ~ 2 N·m

Commercially available round pipeφ28.0

Hexagon socket head cap screw tightening hole

HKV4-core × AWG18

M4

tap

Hexagon socket head cap screwM6 × 15 (Included)Tightening torque1.5 ~ 2 N·m

Commercially available round pipeφ28.0

Hexagon socket head cap screwM6 × 15 (Included)Tightening torque1.5 ~ 2 N·m

Commercially available round pipeφ28.0

M6 �ange nut

Hexagon socket head cap screwM6 × 15 (Included)Tightening torque1.5 ~ 2 N·m

Commercially available round pipeφ28.0

M6×25Hexagon socket head cap screw *The one end of

A0102-CNE-20 is a discrete wire.

Cable duct (cover)

Cable duct (base)

Setting port

Setting port

Housing:Manufactured by JST EHR-2Contact:Manufactured by JST SEH-001T-P0.6

Back face

UL 202764-core × No.23AWGφ4.6 Gray

Mounting hole 4-φ2.7Depth 8mm

Magnet sheet

AWG24 UL1007 red used

AWG24 UL1007 black used

BL227XB-F04V-P

18 (18)110

36

365

13

(66)

36

(150)

18 9

30

1=DN2=DP3=0V4=24V (138)

(19.5

)40

BL227XB-F04VL-P

18 (18)110

36

365

36

(150)

18 9

30

1=DN2=DP3=0V4=24V (138)

(19.5

)40

A027-HP28-5P

12.7

518

4.5

2.51.5

15

18 (18)

2

60

36

3040

2-φ4

18

18

1

4

A027-HP28-H1-5P

40

2-φ

4

60

36

18

418 (32)

A027-HP-SUS2

60

36

40

18

(7.3

)7.3

15.3516

2-φ

3.5

B292XB-0□□L / A092-DM / A0102-CN□-□□

BL2101XB-02VL-P

A092-DM

A0102-CN□-□□

9

1

9 12

452 2

15

11

815

9

41

30  :A0102-CND-03 50  :A0102-CND-05100  :A0102-CND-10150  :A0102-CND-15200  :A0102-CND-20

R/W

4=24V3=0V2=DP1=DN

40

130

92 9.5

57

110

12.5

7.5

ARW-04

100

61 19

+5-0+5-0+5-0+5-0+5-0

Unit: mm

Outline Dimensional Drawings

Page 36: カタログ ASLINKPOKAYOKE 英語 PDF · POKA-YOKE is a global common word The POKAYOKE system comprising the AnyWire POKAYOKE terminal provides a solution to this problem simply

POKAYOKE catalogDB A20 series catalog

DB A40 series catalog

AnyWireASLINK system Introduction Case Examples

Energy monitoring energy saving support catalog

AnyWireASLINK system catalog

Sensor solution iQ Sensor Solution

L (NA) 08253

MITSUBISHI & AnywireL (NA) 08198

Mitsubishi Electric Corporation Product catalog

Price, speci�cations and design may be subject to change without notice.

2018 copyright Anywire Corporation in Japan. October 2018 aspicpcc-e

<Warranty> <Notes on Safety> ●: WARNING ○: CAUTION◇Warranty period

The warranty on the delivered Product shall continue to be effective for one (1) year after the delivery thereof to a location designated by the original owner.◇Scope of warranty

Should a defect occur in any part of the Product during the foregoing warranty period when it is used normally in accordance with the speci�cations described in this User's Manual, the Company shall replace or repair the defect free of charge, except when it arises as a result of:

(1) Misuse or abuse of the Product by the owner;(2) Fault caused by reason of other than the delivered Product;(3) The unauthorized modi�cation or repair of the Product by any person other than the Company's personnel;(4) Any unusual force of nature, disaster or other cause beyond the Company's control.

The term "warranty," as used herein, refers to the warranty applicable to the delivered product alone. The Company shall not be liable for consequential or incidental damage resulting from any malfunction.◇Repair at cost

After the expiration of the warranty period, the owner shall be responsible for all costs and expenses incurred for the troubleshooting and repair of the Product. Even during the warranty term, the Company shall repair any defects arising from causes other than within the scope of the warranty as speci�ed above, at the owner's cost.

●System Safety- This system is intended for general industrial applications. It does not include functions for supporting applications requiring higher levels of safety such as safety-related devices or accident prevention systems. The product must not be used for these purposes.

- Always turn off the power before attempting to mount or replace.

○System power supplyUse a stable, 24V DC power supply. Use of an unstable power supply may cause problems with the system.

○Separately route high-voltage and power cablesAlthough the system has a high noise margin, separate the transmission line and the input/output cables from the high voltage line and the power line.

○Connector and terminal connection* Pay careful attention to the length and installation of cable wiring to ensure that connectors and cables are neither overloaded nor disconnected.* Make sure to prevent any metal objects from getting inside the connectors or the terminal blocks.* Short-circuits caused by metal objects or mis-wiring are likely to damage the device.

○Do not impose any external loads on the units. Doing so may cause a failure.○Do not disconnect or reconnect between the transmission line and slave units. A malfunction may occur.○Use the POKAYOKE terminal series, DB A20 series, Bitty series within the range of the speci�cations and conditions speci�ed in each manual.

Comments/suggestions about AnyWire products:

ISO9001 / 1400Certi�cation

ISO9001 Applicable scope: Headquarters, East Japan Of�ce, Kyoto FactoryISO14001 Applicable scope: Headquarters, Kyoto Factory

Anywire Corporation

http://www.anywire.jp

□ Headquarters1 Babazusho, Nagaokakyo-shi, Kyoto 617-8550 JAPAN

Contact

□□

Contact by mail [email protected] by website http://www.anywire.jp