EVERFINE GONIOPHOTOMETERS SYSTEM TEST REPORT Page 1...

14
EVERFINE GONIOPHOTOMETERS SYSTEM TEST REPORT Page 1 Of 14 LUMINAIRE PHOTOMETRIC TEST REPORT NAME: ASD-CDL2-6A22CC (5000K) SPEC.: MFR.: ASD LIGHTING CORP TYPE: DIM.: SUR.: WEIGHT: SERIAL No.: Shielding Angle: C0 PLANE ISOLUX DIAGRAM (UNIT:lx) MH(m) 10 14 18 22 26 30 34 38 42 46 50 0.0 16.5 33.0 S(m) 5.70 4.70 3.80 2.80 1.90 0.9500 0.7600 0.4700 0.3800 0.2800 0 30 60 90 120 150 -/+180 -150 -120 -90 -60 -30 UNIT:cd C0/180,94.6 UNIT:cd C30/210,94.4 UNIT:cd C60/240,93.0 UNIT:cd C90/270,92.1 AVERAGE BEAM ANGLE(50%):93.5 DEG 0 190 380 570 760 950 LUMINOUS INTENSITY DISTRIBUTION DIAGRAM DATA OF LAMP PHOTOMETRIC DATA Eff: 102.92 lm/W MODEL NOMINAL POWER(W) RATED VOLTAGE(V) NOMINAL FLUX(lm) LAMPS INSIDE TEST VOLTAGE(V) Imax(cd) LOR(%) TOTAL FLUX(lm) CIE CLASS up(%) down(%) h h S/MH(C0/180) S/MH(C90/270) UP,DN(C0-180) UP,DN(C180-360) CIBSE SHR NOM CIBSE SHR MAX h h ASD-CDL2-6A22CC 22 110-277 2018.42 1 120 949.2 100.0 2018.4 DIRECT 0.9 99.1 1.19 1.19 0.5,50.0 0.4,49.1 1.25 1.35 C Range: 0 - 360DEG C Interval: 15.0DEG Range: 0 - 180DEG Interval: 1.0DEG g g Test Speed: HIGH Test System:EVERFINE GO-2000B_V1 SYSTEM V2.00.421 Temperature:25.3DEG Humidity:65.0% Test Distance:8.110m [K=1.0937] Operators:WANG Test Date:2019-12-03 Remarks:

Transcript of EVERFINE GONIOPHOTOMETERS SYSTEM TEST REPORT Page 1...

Page 1: EVERFINE GONIOPHOTOMETERS SYSTEM TEST REPORT Page 1 …files.asd-lighting.com/5F/5C/5F5C9A6FF8BF5B0F8CAE... · 2020-06-04 · everfine goniophotometers system test report page 2 of

EVERFINE GONIOPHOTOMETERS SYSTEM TEST REPORT Page 1 Of 14

LUMINAIRE PHOTOMETRIC TEST REPORT

NAME: ASD-CDL2-6A22CC (5000K)

SPEC.:

MFR.: ASD LIGHTING CORP

TYPE:

DIM.:

SUR.:

WEIGHT:

SERIAL No.:

Shielding Angle:

C0 PLANE ISOLUX DIAGRAM (UNIT:lx)MH(m)10

14

18

22

26

30

34

38

42

46

500.0 16.5 33.0

S(m)5.704.703.802.801.90

0.95000.76000.47000.38000.2800

030

60

90

120

150-/+180

-150

-120

-90

-60

-30

UNIT:cdC0/180,94.6

UNIT:cd

C30/210,94.4

UNIT:cd

C60/240,93.0

UNIT:cd

C90/270,92.1AVERAGE BEAM ANGLE(50%):93.5 DEG

0

190

380

570

760

950

LUMINOUS INTENSITY DISTRIBUTION DIAGRAM

DATA OF LAMP PHOTOMETRIC DATA Eff: 102.92 lm/WMODELNOMINAL POWER(W)RATED VOLTAGE(V)NOMINAL FLUX(lm)LAMPS INSIDETEST VOLTAGE(V)

Imax(cd)LOR(%)TOTAL FLUX(lm)CIE CLASS up(%) down(%)h

h

S/MH(C0/180)S/MH(C90/270) UP,DN(C0-180) UP,DN(C180-360)CIBSE SHR NOMCIBSE SHR MAX

h

h

ASD-CDL2-6A22CC22110-2772018.421120

949.2100.02018.4DIRECT0.999.1

1.191.190.5,50.0

0.4,49.1

1.251.35

C Range: 0 - 360DEGC Interval: 15.0DEG

Range: 0 - 180DEG Interval: 1.0DEGggTest Speed: HIGH Test System:EVERFINE GO-2000B_V1 SYSTEM V2.00.421

Temperature:25.3DEG Humidity:65.0%Test Distance:8.110m [K=1.0937]Operators:WANG

Test Date:2019-12-03 Remarks:

Page 2: EVERFINE GONIOPHOTOMETERS SYSTEM TEST REPORT Page 1 …files.asd-lighting.com/5F/5C/5F5C9A6FF8BF5B0F8CAE... · 2020-06-04 · everfine goniophotometers system test report page 2 of

EVERFINE GONIOPHOTOMETERS SYSTEM TEST REPORT Page 2 Of 14

ZONAL FLUX DIAGRAM

ZONAL FLUX DIAGRAM:

g

10 0- 10

20 10- 20

30 20- 30

40 30- 40

50 40- 50

60 50- 60

70 60- 70

80 70- 80

90 80- 90

100 90-100

110 100-110

120 110-120

130 120-130

140 130-140

150 140-150

160 150-160

170 160-170

180 170-180

C0 C45 C90 C135 C180 C225 C270 C315 zone total %lum,lamp g F F

DEG LUMINOUS INTENSITY:cd UNIT:lm

930.1 930.6 929.1 927.2 926.3 926.3 927.8 928.6 89.60 89.60 4.44,4.44

867.6 869.1 867.0 863.3 861.6 861.4 864.2 865.5 254.2 343.8 17,17

763.5 766.2 763.0 758.7 756.1 754.9 758.7 761.3 376.2 720.0 35.7,35.7

622.6 625.1 611.8 613.9 610.8 605.7 599.7 617.3 432.0 1152 57.1,57.1

428.5 424.8 394.7 407.3 404.9 391.3 371.9 407.8 393.9 1546 76.6,76.6

230.3 226.1 194.5 208.2 210.6 199.1 178.0 206.2 267.4 1813 89.8,89.8

91.15 84.84 67.57 76.80 82.41 74.25 63.61 76.07 134.1 1947 96.5,96.5

22.43 20.07 17.60 19.23 20.83 18.82 17.65 19.58 44.23 1992 98.7,98.7

0.5496 0.5153 0.4713 0.5371 0.4711 0.4711 0.4046 0.4486 8.365 2000 99.1,99.1

1.085 1.020 0.9849 1.058 0.9920 0.9632 0.8701 0.9127 0.7753 2001 99.1,99.1

1.865 1.795 1.760 1.838 1.751 1.711 1.618 1.649 1.426 2002 99.2,99.2

2.796 2.692 2.690 2.763 2.648 2.575 2.509 2.512 2.165 2004 99.3,99.3

3.715 3.645 3.676 3.704 3.573 3.505 3.462 3.436 2.790 2007 99.4,99.4

4.579 4.515 4.573 4.561 4.432 4.364 4.326 4.305 3.104 2010 99.6,99.6

5.388 5.307 5.332 5.381 5.229 5.211 5.129 5.114 3.037 2013 99.7,99.7

6.147 6.104 6.151 6.205 6.049 6.064 6.020 5.949 2.611 2016 99.9,99.9

6.801 6.769 6.833 6.875 6.774 6.818 6.762 6.724 1.822 2018 100,100

7.128 7.206 7.160 7.206 7.128 7.206 7.160 7.212 0.6643 2018 100,100

C Range: 0 - 360DEGC Interval: 15.0DEG

Range: 0 - 180DEG Interval: 1.0DEGggTest Speed: HIGH Test System:EVERFINE GO-2000B_V1 SYSTEM V2.00.421

Temperature:25.3DEG Humidity:65.0%Test Distance:8.110m [K=1.0937]Operators:WANG

Test Date:2019-12-03 Remarks:

Page 3: EVERFINE GONIOPHOTOMETERS SYSTEM TEST REPORT Page 1 …files.asd-lighting.com/5F/5C/5F5C9A6FF8BF5B0F8CAE... · 2020-06-04 · everfine goniophotometers system test report page 2 of

EVERFINE GONIOPHOTOMETERS SYSTEM TEST REPORT Page 3 Of 14

LUMINANCE LIMITATION CURVES

NAME: ASD-CDL2-6A22CC (5000K)

SPEC.:

MFR.: ASD LIGHTING CORP

TYPE:

DIM.:

SUR.:

WEIGHT:

SERIAL No.:

Shielding Angle:

LUMINANCE LIMITATION CURVESGLARE CLASS ILLUMINANCE (lx)1.15 A 2000 1000 500 <=3001.50 B 2000 1000 500 <=3001.85 C 2000 1000 500 <=3002.20 D 2000 1000 500 <=3002.55 E 2000 1000 500 <=300

a b c d e f g h

45

55

65

75

85G(DEG)

8 1000 2 3 4 5 6 8 10000 2 3 4 1

2

34

86

a/h

LUMINANCE (cd/(m2))

a b c d e f g h

C0/180 C90/270

LUMINANCE cd/(m2)G(DEG) C0/180 C90/270

85 1053 53580 1291 101475 1783 128470 2665 197565 3618 288460 4606 389055 5651 499550 6665 614045 7527 7186

C Range: 0 - 360DEGC Interval: 15.0DEG

Range: 0 - 180DEG Interval: 1.0DEGggTest Speed: HIGH Test System:EVERFINE GO-2000B_V1 SYSTEM V2.00.421

Temperature:25.3DEG Humidity:65.0%Test Distance:8.110m [K=1.0937]Operators:WANG

Test Date:2019-12-03 Remarks:

Page 4: EVERFINE GONIOPHOTOMETERS SYSTEM TEST REPORT Page 1 …files.asd-lighting.com/5F/5C/5F5C9A6FF8BF5B0F8CAE... · 2020-06-04 · everfine goniophotometers system test report page 2 of

EVERFINE GONIOPHOTOMETERS SYSTEM TEST REPORT Page 4 Of 14

CU AND LUMINAIRE BUDGETARY ESTIMATE DIAGRAM

NAME: ASD-CDL2-6A22CC (5000K)

SPEC.:

MFR.: ASD LIGHTING CORP

TYPE:

DIM.:

SUR.:

WEIGHT:

SERIAL No.:

Shielding Angle:

cc w fc

r

r

r

RCR Coefficients of Utilization(CU)RCR:Room Cavity Ratio

80%50% 30% 10%

20%

70%50% 30% 10%

20%

50%50% 30% 10%

20%

30%50% 30% 10%

20%

10%50% 30% 10%

20%

000

0.0 1.0 2.0 3.0 4.0 5.0 6.0 7.0 8.0 9.010.0

1.191.07.95.85.77.69.63.57.53.49.45

1.191.03.90.78.69.61.55.49.45.41.38

1.191.00.85.73.63.55.49.44.39.36.33

1.161.04.93.84.75.68.62.57.52.48.44

1.161.01.88.77.68.61.54.49.45.41.37

1.16.98.84.72.63.55.49.44.39.36.33

1.111.00.90.81.73.66.60.55.51.47.43

1.11.98.85.75.67.59.53.48.44.40.37

1.11.95.82.71.62.54.48.43.39.35.32

1.06.96.87.78.70.64.58.54.49.46.42

1.06.94.83.73.65.58.52.47.43.40.36

1.06.92.80.69.61.54.48.43.39.35.32

1.01.92.83.75.68.62.57.52.48.45.42

1.01.91.81.71.64.57.52.47.43.39.36

1.01.89.78.68.60.53.47.43.38.35.32

.99

.87

.76

.66

.58

.51

.45

.41

.37

.33

.30

AREA(m2)10 20 30 40 50 70 100 200 300 500 700 1k 2k 3k 4k 5k 7k2

3

456789

10

20

30

4050LAMPS LUMINAIRE BUDGETARY DIAGRAM

45 6 6

HHH===777

45

66

H=7H=7

CONDITIONSFLUX 5000lm

FACTOR 0.70Hdown 0.00mHwork 0.00m

Ework(AVE) 100lxr (%) cc w fc

70 50 3050 30 20

C Range: 0 - 360DEGC Interval: 15.0DEG

Range: 0 - 180DEG Interval: 1.0DEGggTest Speed: HIGH Test System:EVERFINE GO-2000B_V1 SYSTEM V2.00.421

Temperature:25.3DEG Humidity:65.0%Test Distance:8.110m [K=1.0937]Operators:WANG

Test Date:2019-12-03 Remarks:

Page 5: EVERFINE GONIOPHOTOMETERS SYSTEM TEST REPORT Page 1 …files.asd-lighting.com/5F/5C/5F5C9A6FF8BF5B0F8CAE... · 2020-06-04 · everfine goniophotometers system test report page 2 of

EVERFINE GONIOPHOTOMETERS SYSTEM TEST REPORT Page 5 Of 14

WEC AND CCEC

NAME: ASD-CDL2-6A22CC (5000K)

SPEC.:

MFR.: ASD LIGHTING CORP

TYPE:

DIM.:

SUR.:

WEIGHT:

SERIAL No.:

Shielding Angle:

ccwfc

r

r

r

RCR Wall Exitance Coeffcients(WEC)RCR:Room Cavity Ratio

80%50% 30% 10%

20%

70%50% 30% 10%

20%

50%50% 30% 10%

20%

30%50% 30% 10%

20%

10%50% 30% 10%

20%

000

0.01.02.03.04.05.06.07.08.09.0

10.0

.250

.243

.231

.217

.204

.192

.181

.171

.161

.153

.142

.133

.123

.113

.104

.096

.089

.083

.078

.073

.045

.041

.037

.033

.030

.028

.025

.023

.022

.020

.243

.237

.225

.212

.200

.188

.177

.168

.158

.150

.138

.130

.121

.111

.103

.095

.088

.082

.077

.073

.044

.040

.036

.033

.030

.027

.025

.023

.022

.020

.229

.225

.215

.203

.192

.181

.171

.162

.153

.145

.131

.125

.116

.108

.100

.093

.086

.081

.076

.071

.042

.039

.035

.032

.029

.027

.025

.023

.021

.020

.217

.214

.205

.195

.184

.174

.165

.156

.148

.141

.125

.120

.112

.105

.097

.091

.085

.079

.074

.070

.040

.038

.034

.032

.029

.027

.025

.023

.021

.020

.205

.204

.196

.187

.177

.168

.159

.151

.144

.137

.119

.115

.109

.102

.095

.088

.083

.078

.073

.069

.038

.036

.034

.031

.028

.026

.024

.023

.021

.020

ccwfc

r

r

r

RCR Ceiling Cavity Exitance Coefficients(CCEC)RCR:Room Cavity Ratio

80%50% 30% 10%

20%

70%50% 30% 10%

20%

50%50% 30% 10%

20%

30%50% 30% 10%

20%

10%50% 30% 10%

20%

000

0.01.02.03.04.05.06.07.08.09.0

10.0

.197

.183

.173

.164

.156

.149

.142

.136

.130

.124

.119

.197

.164

.139

.121

.107

.097

.088

.081

.075

.070

.066

.197

.146

.111

.087

.070

.058

.049

.043

.038

.034

.031

.169

.157

.148

.141

.134

.128

.122

.117

.112

.107

.103

.169

.140

.120

.104

.093

.084

.076

.070

.065

.061

.057

.169

.126

.096

.075

.061

.051

.043

.037

.033

.030

.027

.115

.107

.101

.097

.092

.088

.084

.081

.077

.074

.071

.115

.097

.083

.073

.065

.058

.053

.049

.046

.043

.040

.115

.087

.067

.053

.043

.036

.030

.026

.023

.021

.019

.066

.062

.058

.056

.053

.051

.049

.047

.045

.043

.042

.066

.056

.048

.042

.038

.034

.031

.029

.027

.025

.024

.066

.051

.039

.031

.025

.021

.018

.016

.014

.013

.011

.021

.020

.019

.018

.017

.016

.016

.015

.015

.014

.013

.021

.018

.016

.014

.012

.011

.010

.010

.009

.008

.008

.021

.016

.013

.010

.008

.007

.006

.005

.005

.004

.004

C Range: 0 - 360DEGC Interval: 15.0DEG

Range: 0 - 180DEG Interval: 1.0DEGggTest Speed: HIGH Test System:EVERFINE GO-2000B_V1 SYSTEM V2.00.421

Temperature:25.3DEG Humidity:65.0%Test Distance:8.110m [K=1.0937]Operators:WANG

Test Date:2019-12-03 Remarks:

Page 6: EVERFINE GONIOPHOTOMETERS SYSTEM TEST REPORT Page 1 …files.asd-lighting.com/5F/5C/5F5C9A6FF8BF5B0F8CAE... · 2020-06-04 · everfine goniophotometers system test report page 2 of

EVERFINE GONIOPHOTOMETERS SYSTEM TEST REPORT Page 6 Of 14

UGR(Unified Glare Rating) Table

NAME: ASD-CDL2-6A22CC (5000K)

SPEC.:

MFR.: ASD LIGHTING CORP

TYPE:

DIM.:

SUR.:

WEIGHT:

SERIAL No.:

Shielding Angle:

ceiling/cavitywalls

working planeRoom dimensions Viewed crosswise Viewed endwise

0.7 0.70.5 0.50.2 0.2

0.7 0.70.3 0.30.2 0.2

0.5 0.50.5 0.50.2 0.2

0.5 0.50.3 0.30.2 0.2

0.3 0.30.3 0.30.2 0.2

x = 2H y = 2H3H4H6H8H

12H

4H 2H3H4H6H8H

12H

8H 4H6H8H

12H

12H 4H6H8H

16.1 15.617.5 16.916.4 15.917.7 17.217.9 17.416.6 15.917.9 17.116.9 16.218.1 17.418.3 17.616.7 15.917.9 17.117.0 16.218.1 17.318.4 17.616.7 15.917.8 17.017.0 16.218.0 17.318.3 17.516.7 15.917.7 16.917.0 16.218.0 17.218.3 17.516.6 15.817.6 16.817.0 16.217.9 17.118.3 17.4

16.3 15.917.5 17.016.6 16.217.7 17.318.0 17.616.9 16.317.9 17.317.3 16.618.2 17.618.6 17.917.1 16.318.0 17.217.4 16.718.3 17.618.6 17.917.1 16.317.9 17.117.5 16.818.3 17.518.6 17.917.1 16.317.8 17.117.5 16.818.2 17.418.6 17.817.1 16.317.8 17.017.5 16.718.2 17.418.6 17.8

17.0 16.317.8 17.117.4 16.718.1 17.418.5 17.817.1 16.417.7 17.017.5 16.818.1 17.418.6 17.817.1 16.417.6 16.917.6 16.818.1 17.318.6 17.817.1 16.417.6 16.817.6 16.818.0 17.318.5 17.8

17.0 16.317.7 17.017.4 16.718.0 17.418.5 17.817.1 16.417.6 16.917.5 16.818.0 17.318.5 17.817.1 16.417.6 16.817.6 16.918.0 17.318.5 17.8

Variations with the observer position at spacings:S = 1.0H + 0.6 / - 0.7 + 0.7 / - 0.9

1.5H + 0.3 / - 0.4 + 0.3 / - 0.42.0H + 1.1 / - 1.2 + 1.3 / - 1.5

CIE Pub.117, 2018 lm Total Lamp Luminous Flux Correct (8log(F/F0) = 2.4)Area: 0.1 m2

C Range: 0 - 360DEGC Interval: 15.0DEG

Range: 0 - 180DEG Interval: 1.0DEGggTest Speed: HIGH Test System:EVERFINE GO-2000B_V1 SYSTEM V2.00.421

Temperature:25.3DEG Humidity:65.0%Test Distance:8.110m [K=1.0937]Operators:WANG

Test Date:2019-12-03 Remarks:

Page 7: EVERFINE GONIOPHOTOMETERS SYSTEM TEST REPORT Page 1 …files.asd-lighting.com/5F/5C/5F5C9A6FF8BF5B0F8CAE... · 2020-06-04 · everfine goniophotometers system test report page 2 of

EVERFINE GONIOPHOTOMETERS SYSTEM TEST REPORT Page 7 Of 14

UTILIZATION FACTORS TABLE

NAME: ASD-CDL2-6A22CC (5000K)

SPEC.:

MFR.: ASD LIGHTING CORP

TYPE:

DIM.:

SUR.:

WEIGHT:

SERIAL No.:

Shielding Angle:

REFLECTANCE

Ceiling

Walls

Working plane

0.8

0.7

0.2

0.8

0.5

0.2

0.8

0.3

0.2

0.7

0.7

0.2

0.7

0.5

0.2

0.7

0.3

0.2

0.5

0.7

0.2

0.5

0.5

0.2

0.5

0.3

0.2

0

0

0

ROOM INDEX UTILIZATION FACTORS(PERCENT) k(RI) x RCR = 5

k = 0.60 64 54 48 64 54 48 63 53 47 42

0.80 75 65 58 74 64 58 72 63 58 51

1.00 83 74 67 82 73 67 80 74 66 60

1.25 90 81 75 88 80 75 86 79 74 67

1.50 94 86 80 92 85 80 90 83 79 72

2.00 100 93 88 98 92 87 95 90 85 78

2.50 103 97 92 101 95 91 97 93 89 81

3.00 106 100 96 104 99 95 100 96 92 84

4.00 109 104 101 107 103 99 102 99 96 88

5.00 111 107 104 108 105 102 104 101 99 90

ROOM INDEX UF(total) Direct

According to DIN EN 13032-2 2004 SHRNOM = 1.25Suspended

C Range: 0 - 360DEGC Interval: 15.0DEG

Range: 0 - 180DEG Interval: 1.0DEGggTest Speed: HIGH Test System:EVERFINE GO-2000B_V1 SYSTEM V2.00.421

Temperature:25.3DEG Humidity:65.0%Test Distance:8.110m [K=1.0937]Operators:WANG

Test Date:2019-12-03 Remarks:

Page 8: EVERFINE GONIOPHOTOMETERS SYSTEM TEST REPORT Page 1 …files.asd-lighting.com/5F/5C/5F5C9A6FF8BF5B0F8CAE... · 2020-06-04 · everfine goniophotometers system test report page 2 of

EVERFINE GONIOPHOTOMETERS SYSTEM TEST REPORT Page 8 Of 14

ISOCANDELA DIAGRAM

NAME: ASD-CDL2-6A22CC (5000K)

SPEC.:

MFR.: ASD LIGHTING CORP

TYPE:

DIM.:

SUR.:

WEIGHT:

SERIAL No.:

Shielding Angle:

-90-90

-80

-80

-70

-70

-60

-60

-50

-50

-40

-40

-30

-30

-20

-20

-10

-10

0

0

10

10

20

20

30

30

40

40

50

50

60

60

70

70

80

80

90

90HORIZONTAL(DEG)

VERT

ICAL

(DEG

)

Imax:949.3(H1.0,V0.5) (At:C=30.0,Gamma=1.0)UNIT: cd

10% 94.9320% 189.930% 284.840% 379.750% 474.760% 569.670% 664.580% 759.590% 854.4

MAX = 949.34 MIN = 274.90 AVG = 725.90 AVG/MAX = 0.76MIN/MAX = 0.29

C Range: 0 - 360DEGC Interval: 15.0DEG

Range: 0 - 180DEG Interval: 1.0DEGggTest Speed: HIGH Test System:EVERFINE GO-2000B_V1 SYSTEM V2.00.421

Temperature:25.3DEG Humidity:65.0%Test Distance:8.110m [K=1.0937]Operators:WANG

Test Date:2019-12-03 Remarks:

Page 9: EVERFINE GONIOPHOTOMETERS SYSTEM TEST REPORT Page 1 …files.asd-lighting.com/5F/5C/5F5C9A6FF8BF5B0F8CAE... · 2020-06-04 · everfine goniophotometers system test report page 2 of

EVERFINE GONIOPHOTOMETERS SYSTEM TEST REPORT Page 9 Of 14

AAI Figure

NAME: ASD-CDL2-6A22CC (5000K)

SPEC.:

MFR.: ASD LIGHTING CORP

TYPE:

DIM.:

SUR.:

WEIGHT:

SERIAL No.:

Shielding Angle:

1m 207.46cm398.1,949.4lx

2m 414.93cm99.53,237.3lx

3m 622.39cm44.24,105.5lx

4m 829.85cm24.88,59.34lx

5m 1037.32cm15.93,37.98lx

6m 1244.78cm11.06,26.37lx

7m 1452.24cm8.125,19.38lx

8m 1659.71cm6.221,14.83lx

9m 1867.17cm4.915,11.72lx

10m 2074.63cm3.981,9.494lx

Height Eavg,Emax DiameterAngle:92.10deg

Flux out:1438 lm

Note:The Curves indicate the illuminated area and the average illumination when the luminaire is at different distance.

C Range: 0 - 360DEGC Interval: 15.0DEG

Range: 0 - 180DEG Interval: 1.0DEGggTest Speed: HIGH Test System:EVERFINE GO-2000B_V1 SYSTEM V2.00.421

Temperature:25.3DEG Humidity:65.0%Test Distance:8.110m [K=1.0937]Operators:WANG

Test Date:2019-12-03 Remarks:

Page 10: EVERFINE GONIOPHOTOMETERS SYSTEM TEST REPORT Page 1 …files.asd-lighting.com/5F/5C/5F5C9A6FF8BF5B0F8CAE... · 2020-06-04 · everfine goniophotometers system test report page 2 of

EVERFINE GONIOPHOTOMETERS SYSTEM TEST REPORT Page 10 Of 14

ISOLUX DIAGRAM

NAME: ASD-CDL2-6A22CC (5000K)

SPEC.:

MFR.: ASD LIGHTING CORP

TYPE:

DIM.:

SUR.:

WEIGHT:

SERIAL No.:

Shielding Angle:

131.2' 40.00m

105.0' 32.00m

32.00m

105.0'

78.7' 24.00m

52.5' 16.00m

16.00m

52.5'

26.2' 8.00m

0.0' 0.00m

0.00m

0.0'

26.2' 8.00m

52.5' 16.00m

16.00m

52.5'

78.7' 24.00m

105.0' 32.00m

32.00m

105.0'

131.2' 40.00m

MOUNTING HEIGHT: 33'(10.0m)

3% 0.2846lx 0.02644fc 5% 0.4744lx 0.04407fc 10% 0.9487lx 0.08814fc 30% 2.846lx 0.2644fc 50% 4.744lx 0.4407fc

C Range: 0 - 360DEGC Interval: 15.0DEG

Range: 0 - 180DEG Interval: 1.0DEGggTest Speed: HIGH Test System:EVERFINE GO-2000B_V1 SYSTEM V2.00.421

Temperature:25.3DEG Humidity:65.0%Test Distance:8.110m [K=1.0937]Operators:WANG

Test Date:2019-12-03 Remarks:

Page 11: EVERFINE GONIOPHOTOMETERS SYSTEM TEST REPORT Page 1 …files.asd-lighting.com/5F/5C/5F5C9A6FF8BF5B0F8CAE... · 2020-06-04 · everfine goniophotometers system test report page 2 of

EVERFINE GONIOPHOTOMETERS SYSTEM TEST REPORT Page 11 Of 14

LED Avg.L Report

NAME: ASD-CDL2-6A22CC (5000K)

SPEC.:

MFR.: ASD LIGHTING CORP

TYPE:

DIM.:

SUR.:

WEIGHT:

SERIAL No.:

Shielding Angle:

AvgL cd/m2L_0~180(65)av 3446L_0~180(75)av 1711L_0~180(85)av 1029L_90~270(65)av 2768L_90~270(75)av 1271L_90~270(85)av 542

L_45(65)av 3204L_45(75)av 1494L_45(85)av 737

Standard: GB/T 29293-2012

C Range: 0 - 360DEGC Interval: 15.0DEG

Range: 0 - 180DEG Interval: 1.0DEGggTest Speed: HIGH Test System:EVERFINE GO-2000B_V1 SYSTEM V2.00.421

Temperature:25.3DEG Humidity:65.0%Test Distance:8.110m [K=1.0937]Operators:WANG

Test Date:2019-12-03 Remarks:

Page 12: EVERFINE GONIOPHOTOMETERS SYSTEM TEST REPORT Page 1 …files.asd-lighting.com/5F/5C/5F5C9A6FF8BF5B0F8CAE... · 2020-06-04 · everfine goniophotometers system test report page 2 of

EVERFINE GONIOPHOTOMETERS SYSTEM TEST REPORT Page 12 Of 14

Planar Illuminance Curve

Planar Illuminance Curve

-25 -20 -15 -10 -5 0 5 10 15 20 25Distance(m)

0

0.95

1.9

2.85

3.8

4.75

5.7

6.65

7.6

8.55

9.5E(lx) MH = 10 m

C0/180

C90/270

C Range: 0 - 360DEGC Interval: 15.0DEG

Range: 0 - 180DEG Interval: 1.0DEGggTest Speed: HIGH Test System:EVERFINE GO-2000B_V1 SYSTEM V2.00.421

Temperature:25.3DEG Humidity:65.0%Test Distance:8.110m [K=1.0937]Operators:WANG

Test Date:2019-12-03 Remarks:

Page 13: EVERFINE GONIOPHOTOMETERS SYSTEM TEST REPORT Page 1 …files.asd-lighting.com/5F/5C/5F5C9A6FF8BF5B0F8CAE... · 2020-06-04 · everfine goniophotometers system test report page 2 of

EVERFINE GONIOPHOTOMETERS SYSTEM TEST REPORT Page 13 Of 14

LUMINOUS DISTRIBUTION INTENSITY DATA

NAME: ASD-CDL2-6A22CC (5000K)

SPEC.:

MFR.: ASD LIGHTING CORP

TYPE:

DIM.:

SUR.:

WEIGHT:

SERIAL No.:

Shielding Angle:

(DEG)g

C(DEG) Table--1 UNIT: cd

00 9495 94510 93015 90420 86825 82030 76335 69740 62345 53250 42955 32460 23065 15370 91.275 46.280 22.485 9.1890 0.5595 0.77100 1.08105 1.44110 1.87115 2.32120 2.80125 3.28130 3.72135 4.16140 4.58145 4.99150 5.39155 5.76160 6.15165 6.51170 6.80175 7.01180 7.13

1594994593090586882176569862453543132823415592.646.522.18.770.580.761.071.421.832.302.773.243.694.124.534.965.325.706.096.476.756.997.13

3094994593090586882276569962453442932523215490.544.921.17.550.560.751.061.421.832.272.753.213.664.094.554.955.315.716.096.456.757.017.16

4594994593190586982276669962553142532022614784.841.220.16.540.520.721.021.391.802.232.693.183.654.104.514.905.315.696.106.466.777.057.21

6094994593090586982276569961952241230521113575.836.418.85.590.490.701.001.361.792.212.693.183.654.094.514.905.305.716.136.516.817.077.19

7594994593090586882276569961651440229420112770.634.218.15.030.480.690.981.341.752.192.663.163.634.094.554.925.305.726.156.536.837.057.17

9094994492990386782176369761250839528619512267.633.217.64.660.470.690.981.341.762.212.693.183.684.134.574.965.335.756.156.546.837.037.16

10594994492990386681976269561150939628719512268.133.517.95.020.470.690.991.351.772.222.693.183.644.114.574.955.335.756.176.546.827.047.16

12094994492890186481776069361151140029220012671.234.918.55.590.510.731.031.391.812.252.733.233.704.154.554.935.345.776.186.566.837.077.17

13594994392790086381675969061451740730120813476.838.119.26.450.540.761.061.421.842.282.763.233.704.154.564.975.385.786.216.586.877.117.21

15094994392789986281475768861151640730121013780.240.619.77.320.600.801.111.481.892.352.823.293.734.184.605.015.425.836.246.606.917.147.19

16594994392689986181375668761151540630121113881.941.920.58.340.600.811.121.501.902.362.853.323.784.234.655.075.465.856.246.626.917.117.14

18094994392689986281475668861151440530121113882.442.420.88.750.470.690.991.341.752.182.653.113.574.004.434.835.235.646.056.456.777.007.13

19594994292689886181375568660851040129820913781.341.620.28.230.520.701.001.351.762.192.653.103.564.004.424.845.245.656.086.496.827.047.14

21094994392789986281475668760950940029720813680.040.619.67.480.500.680.981.331.732.152.603.073.523.954.404.815.215.646.076.496.847.087.17

22594994392689986181375568660650239128819912974.237.118.86.330.470.680.961.311.712.122.573.053.513.954.364.775.215.636.066.486.827.107.21

24094994392790086381575768860149538127618812068.334.218.45.730.450.640.931.271.672.082.553.013.483.924.344.745.155.606.046.456.797.077.19

25594994392790086381575668859648637026417811363.932.417.64.850.420.630.901.251.642.072.543.013.463.904.344.745.145.596.046.456.787.047.17

27094994392890186481775969160048937226517811263.632.617.64.780.400.600.871.221.622.052.512.993.463.894.334.745.135.576.026.436.767.017.16

C Range: 0 - 360DEGC Interval: 15.0DEG

Range: 0 - 180DEG Interval: 1.0DEGggTest Speed: HIGH Test System:EVERFINE GO-2000B_V1 SYSTEM V2.00.421

Temperature:25.3DEG Humidity:65.0%Test Distance:8.110m [K=1.0937]Operators:WANG

Test Date:2019-12-03 Remarks:

Page 14: EVERFINE GONIOPHOTOMETERS SYSTEM TEST REPORT Page 1 …files.asd-lighting.com/5F/5C/5F5C9A6FF8BF5B0F8CAE... · 2020-06-04 · everfine goniophotometers system test report page 2 of

EVERFINE GONIOPHOTOMETERS SYSTEM TEST REPORT Page 14 Of 14

LUMINOUS DISTRIBUTION INTENSITY DATA

NAME: ASD-CDL2-6A22CC (5000K)

SPEC.:

MFR.: ASD LIGHTING CORP

TYPE:

DIM.:

SUR.:

WEIGHT:

SERIAL No.:

Shielding Angle:

(DEG)g

C(DEG) Table--2 UNIT: cd

2850 9495 94410 92815 90120 86425 81730 75935 69140 60345 49450 37755 26860 18065 11470 64.475 32.880 17.885 4.8190 0.4195 0.61100 0.88105 1.23110 1.63115 2.05120 2.50125 2.98130 3.43135 3.88140 4.31145 4.71150 5.10155 5.55160 6.02165 6.43170 6.76175 7.03180 7.16

30094994492990286581876169361150739228319212269.335.018.75.650.430.620.891.241.632.052.512.983.423.884.304.695.105.556.006.406.757.037.18

31594994492990286581876169461751940829920613276.138.319.66.380.450.640.911.261.652.062.512.983.443.894.314.695.115.525.956.366.727.037.21

33094994593090486782076469762253042231522114484.642.720.97.650.470.640.921.261.662.072.522.983.443.864.294.695.085.505.936.346.707.007.18

34594994593090486882076469762253242632122715088.945.021.88.660.470.660.931.281.682.092.553.003.443.874.284.705.095.515.946.396.716.987.15

C Range: 0 - 360DEGC Interval: 15.0DEG

Range: 0 - 180DEG Interval: 1.0DEGggTest Speed: HIGH Test System:EVERFINE GO-2000B_V1 SYSTEM V2.00.421

Temperature:25.3DEG Humidity:65.0%Test Distance:8.110m [K=1.0937]Operators:WANG

Test Date:2019-12-03 Remarks: