ERVXXSHA1130, ERVXXSVA1130: Product Data Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations. 1 Product Data A200611 35 to 131 CFM @ 0.2 in. w.g. 35 to 119 CFM @ 0.4 in. w.g. Introducing the industry’s most advanced residential fresh air system, created to offer a universal platform specifically designed and improved to make the contractor’s life easier and more profitable while delivering constant superior air quality. Thanks to new technology, the airflow calibration and auto-balancing are achieved quickly and maintained throughout the life of the product Select the desired CFM (from 35 to 130 CFM) using the very first integrated LCD screen. The airflow is then set up automatically Integrated electronic airflow measurement device with real time LCD Integrated diagnostic tool PMSM ECM motors for very low power consumption Suspended installation (chains included) OR Wall-mount installation (universal brackets included) installation with 2 brackets installation with 4 brackets CORE Coroplast and plastic membrane with polymer base, non washable Dimensions: 12" x 12" x 9" (30.5 cm x 30.5 cm x 23 cm) FILTERS MERV 8 grade washable standard filter (included) Optional MERV13 grade filter part no. SV24285 OPTIONS Complete line of registers and diffusers Compatible with the Tandem transition (part no. KVAAC0101HCO) (for units producing up to 130 CFM only) UNIT DESCRIPTION SRE of 67% at 0°C and 56% at -25°C (64 CFM) Ports size: 5 in. Recirculation Mode and Recirculation Defrost Painted door, corrosion resistant galvanized body One-piece molded insulation shell, no air leakage (expanded polystyrene; UL 94 HF-1 certified) Constant airflow and auto-balancing device Motorized dampers (no additional backdraft dampers required) No drain required 120V, 60 Hz, 2.5 A, 110 W with 6 foot power cord Sound: 70.0 dBA at 115 CFM @ 0.4 in. w.g. 60.1 dBA at 64 CFM @ 0.2 in. w.g. A200636 CONTROLS NOTE: Do not connect the Infinity® System Control directly to the ventilator, as that may cause damage. If you have an Infinity® System Control use one of the optional Main Wall Controls. Please do not connect the Network Interface Module (NIM) or the Infinity® Damper Control Module to the two terminal blocks on the new ventilator. The new ventilator terminals do not match up to the NIM or Infinity® Damper Control terminals. Connecting the two controls may cause damage. A200612CA There are 4 optional main controls and 1 optional auxiliary control available. Refer to the applicable Wall Control specification sheet for more information. NOTE: These controls are compatible only with the latest versions of ERV and HRV ventilators. Older controls will not work with the newest ventilators. ERVXXSHA1130, ERVXXSVA1130 Performance™ Fresh Air Systems – 130 CFM Control Name Description of Modes Model # Premium Touch Screen, Auto 2.0 Fully Configurable, Multiple Modes KVACN0101CPC Automatic Auto 1.0, Filter Alert KVACN0101CAC Dehumidistat Humidity Sensor / Selection KVACN0101CDH Speed Selector 5 Operating Time Periods KVACN0101CSS Auxiliary Bathroom Override 20 - 40 - 60 min. Settings KVACN0101CBO F a b r i q u é a u M a d e i n CANADA CANADA AUTOMATIC BATHROOM OVERRIDE PREMIUM DEHUMIDISTAT SPEED SELECTOR

Transcript of ERV-130-01PD 28 JanEdition Date: 1/21 Catalog No: ERV-130-01PD Replaces: New ERVXXSHA1130,...

Page 1: ERV-130-01PD 28 JanEdition Date: 1/21 Catalog No: ERV-130-01PD Replaces: New ERVXXSHA1130, ERVXXSVA1130: Product Data Manufacturer reserves the right to change, at any …

ERVXXSHA1130, ERVXXSVA1130: Product Data

Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations.1

Product Data

A200611• 35 to 131 CFM @ 0.2 in. w.g.• 35 to 119 CFM @ 0.4 in. w.g.Introducing the industry’s most advanced residential fresh air system,created to offer a universal platform specifically designed and improvedto make the contractor’s life easier and more profitable while deliveringconstant superior air quality.• Thanks to new technology, the airflow calibration and auto-balancing

are achieved quickly and maintained throughout the life of the product• Select the desired CFM (from 35 to 130 CFM) using the very first

integrated LCD screen. The airflow is then set up automatically• Integrated electronic airflow measurement device with real time LCD• Integrated diagnostic tool• PMSM ECM motors for very low power consumption• Suspended installation (chains included)

OR• Wall-mount installation (universal brackets included)

– installation with 2 brackets– installation with 4 brackets

CORE• Coroplast and plastic membrane with polymer base, non washable• Dimensions: 12" x 12" x 9" (30.5 cm x 30.5 cm x 23 cm)

FILTERS• MERV 8 grade washable standard filter (included)• Optional MERV13 grade filter part no. SV24285

OPTIONS• Complete line of registers and diffusers• Compatible with the Tandem transition (part no. KVAAC0101HCO)

(for units producing up to 130 CFM only)

UNIT DESCRIPTION• SRE of 67% at 0°C and 56% at -25°C (64 CFM)• Ports size: 5 in.• Recirculation Mode and Recirculation Defrost• Painted door, corrosion resistant galvanized body• One-piece molded insulation shell, no air leakage (expanded

polystyrene; UL 94 HF-1 certified)• Constant airflow and auto-balancing device• Motorized dampers (no additional backdraft dampers required)• No drain required• 120V, 60 Hz, 2.5 A, 110 W with 6 foot power cord• Sound: 70.0 dBA at 115 CFM @ 0.4 in. w.g.

60.1 dBA at 64 CFM @ 0.2 in. w.g.

A200636

CONTROLSNOTE: Do not connect the Infinity® System Control directly to theventilator, as that may cause damage. If you have an Infinity® SystemControl use one of the optional Main Wall Controls. Please do not connect the Network Interface Module (NIM) or theInfinity® Damper Control Module to the two terminal blocks on the newventilator. The new ventilator terminals do not match up to the NIM orInfinity® Damper Control terminals. Connecting the two controls maycause damage.

A200612CAThere are 4 optional main controls and 1 optional auxiliary controlavailable. Refer to the applicable Wall Control specification sheet formore information.NOTE: These controls are compatible only with the latest versions ofERV and HRV ventilators. Older controls will not work with the newestventilators.

ERVXXSHA1130, ERVXXSVA1130Performance™ Fresh Air Systems – 130 CFM

Control Name Description of Modes Model #

Premium Touch Screen, Auto 2.0 Fully Configurable, Multiple Modes KVACN0101CPC

Automatic Auto 1.0, Filter Alert KVACN0101CACDehumidistat Humidity Sensor / Selection KVACN0101CDHSpeed Selector 5 Operating Time Periods KVACN0101CSSAuxiliaryBathroom Override 20 - 40 - 60 min. Settings KVACN0101CBO

Fabriqué au

Made in

CANADACANADA

AUTOMATICBATHROOMOVERRIDEPREMIUM DEHUMIDISTAT SPEED SELECTOR

Page 2: ERV-130-01PD 28 JanEdition Date: 1/21 Catalog No: ERV-130-01PD Replaces: New ERVXXSHA1130, ERVXXSVA1130: Product Data Manufacturer reserves the right to change, at any …

ERVXXSHA1130, ERVXXSVA1130: Product Data

Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations.2

DIMENSIONS

A200613

• Total assembled weight (core included) - approx 37 lb. (16.8 kg) • Shipping weight - approx 44 lb. (20 kg)

Ø

Ø

EXHAUST AIR FROM BUILDING FRESH AIR TO BUILDING

EXHAUST AIR TO OUTSIDEFRESH AIR FROM OUTSIDE

21”

21-1/2”

19-1/8”

18-3/4” 8” 16-1/8”

8”1”

5” TYP

CLEARANCEFOR DUCTING

POWERCORD

TERMINALS

DRAINS

LATCHES

CLEARANCEREQUIRED FORMAINTENANCE

POWERCORD

TERMINALSDRAINS

LATCHES

CLEARANCEREQUIRED FORMAINTENANCE

CLEARANCEFOR DUCTING

1”

16-1/8”

19-1/8”

5” TYP

23-1/2”

8”

18-3/4”

21”

EXHAUST AIR FROM BUILDING

FRESH AIR TO BUILDING

5” TOP PORTS

5” SIDE PORTS

8”

EXHAUST AIR TO OUTSIDEFRESH AIR FROM OUTSIDE

Page 3: ERV-130-01PD 28 JanEdition Date: 1/21 Catalog No: ERV-130-01PD Replaces: New ERVXXSHA1130, ERVXXSVA1130: Product Data Manufacturer reserves the right to change, at any …

ERVXXSHA1130, ERVXXSVA1130: Product Data

Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations.3

DEFROST SYSTEMNo negative pressure is created by air exhausted to the outdoors since theair is recirculated into the house, helping to prevent any backdraft.

A200615

FAN CURVESThanks to new technology, no need to balance the unit manually. Both PMSM motors are controlled by an artificial intelligence performing 120readings per minute then processing this information to maintain the requested airflow.For typical installation, the software will ensure a balanced ventilation at every selected speed regardless of the weather conditions, the type ofconnection, the variable speed furnace/AHU, the stack effect, the filter clogging and so on. This results in peace of mind for installers and usersknowing that the unit will always remain balanced and that it will maintain its maximum heat/energy recovery efficiency.

A200635

FACTORY SETTING OUTDOOR TEMPERATURE*

-5°C TO -15°C / 23°F TO 5°F -15°C TO -27°C / 5°F TO -17°F -27°C AND LESS / -17°F AND LESS

CFM AIR EXCHANGE IN MINUTES

DEFROST IN MINUTES

AIR EXCHANGE IN MINUTES

DEFROST IN MINUTES

AIR EXCHANGE IN MINUTES

DEFROST IN MINUTES

0 to 59 30 5 18 5 17 860 to 90 40 5 21 5 21 8

91 and more 20 5 15 5 15 8

PLUS OUTDOOR TEMPERATURE*

-5°C TO -15°C / 3°F TO 5°F -15°C TO -27°C / 5°F TO -17°F -27°C AND LESS / -17°F AND LESS

CFM AIR EXCHANGE IN MINUTES

DEFROST IN MINUTES

AIR EXCHANGE IN MINUTES

DEFROST IN MINUTES

AIR EXCHANGE IN MINUTES

DEFROST IN MINUTES

0 to 59 24 7 14 7 14 1060 to 90 30 7 16 7 15 10

91 and more 18 7 12 7 12 10

*Outdoor temperature is read by a thermistor located inside the unit, next to fresh air from outdoor port.

y = -2E-07x3 - 2E-05x2 - 0.0029x + 1.3072R² = 0.9987

0

0.1

0.2

0.3

0.4

0.5

0.6

0.7

0.8

0.9

1

0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150

Net Airflow (CFM)

AIRFLOW IS FULLY ADJUSTABLE WITH 1 CFM INCREMENT

STATIC

P RESSURE

(PA )

STATIC

P RESSURE

(IN . W .G.)

N ET SUPPLY

AIRFLOW

(L/ S)

N ET SUPPLY

AIRFLOW

(CFM )

GROSS

AIRFLOW

SUPPLY

(L/ S)

GROSS

AIRFLOW

SUPPLY

(CFM )

GROSS

AIRFLOW

E XHAUST

(L/ S)

GROSS

AIRFLOW

E XHAUST

(CFM )

25 0.1 64 136 65 138 65 138

50 0.2 62 131 63 133 63 133

75 0.3 58 123 59 125 59 125

100 0.4 56 119 57 121 57 121

125 0.5 53 112 54 114 54 114

150 0.6 49 104 50 106 50 106

175 0.7 45 95 46 97 46 97

200 0.8 41 87 42 89 42 89

225 0.9 36 76 37 78 37 78

250 1.0 30 64 31 66 31 66

Page 4: ERV-130-01PD 28 JanEdition Date: 1/21 Catalog No: ERV-130-01PD Replaces: New ERVXXSHA1130, ERVXXSVA1130: Product Data Manufacturer reserves the right to change, at any …

© 2021 Carrier. All rights reserved. Edition Date: 1/21 Catalog No: ERV-130-01PDReplaces: New

ERVXXSHA1130, ERVXXSVA1130: Product Data

Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations.4

ENERGY PERFORMANCE

REQUIREMENTS AND STANDARDS• UL 1812 compliant (safety)• Could be installed in compliance with CSA F326• Performance tested as per CSA C439 Standard• Complies with ROHS 2015/863 directive• Compliant with Prop 65

SUPPLY TEMPERATURE

NET AIR-FLOW POWER

CONSUMED WATTS

SENSIBLE RECOVERY EFFICIENCY

ADJUSTED SENSIBLE

RECOVERY EFFICIENCY

LATENT RECOVERY / MOISTURE TRANSFER

APPARENT SENSIBLE

EFFECTIVENESS

TOTAL RECOVERY EFFICIENCY

ADJUSTED TOTAL

RECOVERY EFFICIENCY°C °F L/S CFM

HEATING

0 32 30 64 32 67 70 0.65 72 – –

0 32 62 131 112 63 69 0.53 71 – –

-25 -13 30 64 57 56 58 0.62 72 – –

35 95 33 70 36 – – 0.54 60 56 58