Equipment Operation and Maintenance
![Page 2: Equipment Operation and Maintenance. Grid-controlled tube Designed to turn on and off rapidly, providing short precise exposures Use in fluoro and in.](https://reader036.fdocuments.net/reader036/viewer/2022070410/56649ed15503460f94be02be/html5/thumbnails/2.jpg)
Grid-controlled tube
• Designed to turn on and off rapidly, providing short precise exposures
• Use in fluoro and in capacitor discharged (condenser-discharge) mobile units
• Uses a molybdenum focusing cup
![Page 3: Equipment Operation and Maintenance. Grid-controlled tube Designed to turn on and off rapidly, providing short precise exposures Use in fluoro and in.](https://reader036.fdocuments.net/reader036/viewer/2022070410/56649ed15503460f94be02be/html5/thumbnails/3.jpg)
FLUOROSCOPY
• INPUT PHOSPHOR– LARGE DIAMETER– CESIUM IODIDE– X-RAYS LIGHT
• PHOTOCATHODE– LIGHT ELECTRONS
• OUTPUT PHOSPOR– SMALLER DIAMETER– ELECTRONS LIGHT
![Page 4: Equipment Operation and Maintenance. Grid-controlled tube Designed to turn on and off rapidly, providing short precise exposures Use in fluoro and in.](https://reader036.fdocuments.net/reader036/viewer/2022070410/56649ed15503460f94be02be/html5/thumbnails/4.jpg)
FLUORO CONT.
• FOCUSSING LENSES• VIDICOM/PLUMBICON• BEAM SPLITTING DEVICE• mA• ABS• AGC or ABC
![Page 5: Equipment Operation and Maintenance. Grid-controlled tube Designed to turn on and off rapidly, providing short precise exposures Use in fluoro and in.](https://reader036.fdocuments.net/reader036/viewer/2022070410/56649ed15503460f94be02be/html5/thumbnails/5.jpg)
• FLUX GAIN=# OF OUTPUT LIGHT PHOTONS
# OF INPUT LIGHT PHOTONS• MINIFICATION GAIN = Diameter of input (squared) diameter of output (squared• BRIGHTNESS GAIN:
minification x flux
![Page 6: Equipment Operation and Maintenance. Grid-controlled tube Designed to turn on and off rapidly, providing short precise exposures Use in fluoro and in.](https://reader036.fdocuments.net/reader036/viewer/2022070410/56649ed15503460f94be02be/html5/thumbnails/6.jpg)
• Trifield Tubes• 25/17/12
smaller diameter of input phosphor reduces:field of viewmagnificationminification gain dimmer image
![Page 7: Equipment Operation and Maintenance. Grid-controlled tube Designed to turn on and off rapidly, providing short precise exposures Use in fluoro and in.](https://reader036.fdocuments.net/reader036/viewer/2022070410/56649ed15503460f94be02be/html5/thumbnails/7.jpg)
Larger film formatgreater the # of films =higher patient
exposure
• Cinefluoroscopy– rapidly obtained photospot image
(35mm film)15,30,60,90 frames per sec.
– cardiac cath
• Spot film– 12 frames per sec– smaller film size
• cassette loaded
![Page 8: Equipment Operation and Maintenance. Grid-controlled tube Designed to turn on and off rapidly, providing short precise exposures Use in fluoro and in.](https://reader036.fdocuments.net/reader036/viewer/2022070410/56649ed15503460f94be02be/html5/thumbnails/8.jpg)
FLUORO QUESTIONS
#9,24,30,36,38,40,44,47,5463, 69,70
![Page 9: Equipment Operation and Maintenance. Grid-controlled tube Designed to turn on and off rapidly, providing short precise exposures Use in fluoro and in.](https://reader036.fdocuments.net/reader036/viewer/2022070410/56649ed15503460f94be02be/html5/thumbnails/9.jpg)
AEC
![Page 10: Equipment Operation and Maintenance. Grid-controlled tube Designed to turn on and off rapidly, providing short precise exposures Use in fluoro and in.](https://reader036.fdocuments.net/reader036/viewer/2022070410/56649ed15503460f94be02be/html5/thumbnails/10.jpg)
• Collimation and AEC• Photodiode
– light sensitive– under table, behind cassette
• ion chamber– charge sensitive– above bucky and cassette– #10,14,25,27,34,81,92,102,113,
![Page 11: Equipment Operation and Maintenance. Grid-controlled tube Designed to turn on and off rapidly, providing short precise exposures Use in fluoro and in.](https://reader036.fdocuments.net/reader036/viewer/2022070410/56649ed15503460f94be02be/html5/thumbnails/11.jpg)
![Page 12: Equipment Operation and Maintenance. Grid-controlled tube Designed to turn on and off rapidly, providing short precise exposures Use in fluoro and in.](https://reader036.fdocuments.net/reader036/viewer/2022070410/56649ed15503460f94be02be/html5/thumbnails/12.jpg)
CIRCUITS
![Page 13: Equipment Operation and Maintenance. Grid-controlled tube Designed to turn on and off rapidly, providing short precise exposures Use in fluoro and in.](https://reader036.fdocuments.net/reader036/viewer/2022070410/56649ed15503460f94be02be/html5/thumbnails/13.jpg)
• Self induction = autotransformer and choke coil
• Mutual induction =High voltage transformer & filament circuit
• V = VS = NS
VP= NP
• I = NS = IP NP=IS
![Page 14: Equipment Operation and Maintenance. Grid-controlled tube Designed to turn on and off rapidly, providing short precise exposures Use in fluoro and in.](https://reader036.fdocuments.net/reader036/viewer/2022070410/56649ed15503460f94be02be/html5/thumbnails/14.jpg)
• Rectifiers• Filament circuit• rheostat• filament circuit
![Page 15: Equipment Operation and Maintenance. Grid-controlled tube Designed to turn on and off rapidly, providing short precise exposures Use in fluoro and in.](https://reader036.fdocuments.net/reader036/viewer/2022070410/56649ed15503460f94be02be/html5/thumbnails/15.jpg)
• Motor and generators• Rheostat• Star and wye configurations
– transformer windings in 3-phase circuits
– 5,20,23,26,35,45,46 ,51,52,53,74,77
![Page 16: Equipment Operation and Maintenance. Grid-controlled tube Designed to turn on and off rapidly, providing short precise exposures Use in fluoro and in.](https://reader036.fdocuments.net/reader036/viewer/2022070410/56649ed15503460f94be02be/html5/thumbnails/16.jpg)
THREE PHASE/SINGLE PHASE
HU • single phase=ma x time x kvp• three phase/ 6 pulse
ma x time x kvp x 1.35• three phase/12 pulse
ma x time x kvp x 1.41
![Page 17: Equipment Operation and Maintenance. Grid-controlled tube Designed to turn on and off rapidly, providing short precise exposures Use in fluoro and in.](https://reader036.fdocuments.net/reader036/viewer/2022070410/56649ed15503460f94be02be/html5/thumbnails/17.jpg)
VOLTAGE RIPPLE
• Single phase• three phase 6
pulse• three phase 12
pulse
• 100%• 13%• 4 or 3%• ?’s
35,64,96,97,99,105,106
![Page 18: Equipment Operation and Maintenance. Grid-controlled tube Designed to turn on and off rapidly, providing short precise exposures Use in fluoro and in.](https://reader036.fdocuments.net/reader036/viewer/2022070410/56649ed15503460f94be02be/html5/thumbnails/18.jpg)
Tomography
• Thinner the cut the _________the angle
• 43
![Page 19: Equipment Operation and Maintenance. Grid-controlled tube Designed to turn on and off rapidly, providing short precise exposures Use in fluoro and in.](https://reader036.fdocuments.net/reader036/viewer/2022070410/56649ed15503460f94be02be/html5/thumbnails/19.jpg)
QUALITY CONTROL TESTS
• SPINNING TOP TIMER• WIRE MESH SCREEN/FILM CONTACT
• PENETROMETER KVP AND CONTRAST
• STAR PATTERN FOCAL SPOT SIZE• CUTIE PIE ROENTGEN DOSIMETER
• WISCONSIN TEST TOOL KVP IN BEAM• GEIGER RADIOACTIVITY
![Page 20: Equipment Operation and Maintenance. Grid-controlled tube Designed to turn on and off rapidly, providing short precise exposures Use in fluoro and in.](https://reader036.fdocuments.net/reader036/viewer/2022070410/56649ed15503460f94be02be/html5/thumbnails/20.jpg)
spinning top tests
Spinning top testsSpinning top tests• half wave/single phase = exposure time x 60• Full wave/single phase = exposure time x 120 • Three phase –exposure time =arc size/360• timers and rectifiers• dots and dashes(12 dots of 1/10sec, 24 dots of
1/5 sec, 6 dots for 1/20 sec)• synchronous spinning top• solid arc• #18,28,41,50,57,61,66,65,68,
![Page 21: Equipment Operation and Maintenance. Grid-controlled tube Designed to turn on and off rapidly, providing short precise exposures Use in fluoro and in.](https://reader036.fdocuments.net/reader036/viewer/2022070410/56649ed15503460f94be02be/html5/thumbnails/21.jpg)
TUBE LIFE/HEAT LOAD
#6,12,16,33,44,73,77,101,
![Page 22: Equipment Operation and Maintenance. Grid-controlled tube Designed to turn on and off rapidly, providing short precise exposures Use in fluoro and in.](https://reader036.fdocuments.net/reader036/viewer/2022070410/56649ed15503460f94be02be/html5/thumbnails/22.jpg)
Mobile radiography, CT, Misc
• Capacitors- temporarily stores energy-no battery
• 2,3,4,22,37,42,55,58,71,78,87,88,120
![Page 23: Equipment Operation and Maintenance. Grid-controlled tube Designed to turn on and off rapidly, providing short precise exposures Use in fluoro and in.](https://reader036.fdocuments.net/reader036/viewer/2022070410/56649ed15503460f94be02be/html5/thumbnails/23.jpg)
DIGITAL
Corectec
![Page 24: Equipment Operation and Maintenance. Grid-controlled tube Designed to turn on and off rapidly, providing short precise exposures Use in fluoro and in.](https://reader036.fdocuments.net/reader036/viewer/2022070410/56649ed15503460f94be02be/html5/thumbnails/24.jpg)
Misc.
• Light absorbing dye in screens reduce diffusion of fluorescent light