Energy: nuclear power generation...6 Energy: EDF coatings solutions for the nuclear power industry...
Transcript of Energy: nuclear power generation...6 Energy: EDF coatings solutions for the nuclear power industry...
Energy: nuclear power generationEDF coatings solutions for the nuclear power industry
Protective & Marine Coatings
2 Energy: EDF coatings solutions for the nuclear power industry
Nuclear power plants
Sherwin-Williams is a leader in corrosive protection coatings for the nuclear industry and committed to providing tailor-made specifications to fulfil your project requirements. With our global supply chain, skilled technical service network and experience in the nuclear sector, we ensure that your asset will remain protected.
Our global footprint, with local expertise, allows us to supply specifi c
protective coatings to new generation nuclear installations anywhere
in the world, helping you to protect your investment from the world’s
harshest environments.
By their nature, nuclear power plants require the highest standards
of technical performance and safety throughout the supply chain and
we offer the very highest level of technical expertise combined with
experience in this challenging industry.
3Energy: EDF coatings solutions for the nuclear power industry
We provide an unparalleled service to the French nuclear power market. Working with our partner Maestria, we are a recognized leader in our selected market segments including anti corrosive coatings for nuclear power plants and we continually improve our product off ering to meet the ever-changing needs of our customers.
We are technology leaders in the following categories:
• high performance protective coatings
• anti-corrosive coatings for nuclear power plants
• tank linings
• high temperature and under insulation coatings
• passive fire and cryogenic spill protection (FIRETEX® range)
• pipeline coatings
• high performance fl ooring coatings.
Maestria systems are qualifi ed to meet the requirements for each
zone of a nuclear power plant, including the second and third
generation of EPR design. Maestria offers coating systems that
are qualifi ed for all zones, including the reactor containment area.
Maestria partnership
4 Energy: EDF coatings solutions for the nuclear power industry
These specifi cations do not include a level 3 specifi cation.
Testing is based on ASTM/ANSI standards.
The protective coatings are supplied by Sherwin-Williams, these coatings play an integral
part in the functionality and operational reliability of nuclear power plants. We create
products to meet the highest standards in the nuclear industry:
• EDF/AREVA/SGN-COGEMA/CEA/ICORR approvals
• non-toxic products/free from harmful substances
• conformity with directives 1999/13/CE SED and 2004/42/CE COV
• IS0 9001 certifi ed.
Relevant testing and approvals
ASTM/ANSI specifi cations
5Energy: EDF coatings solutions for the nuclear power industry
For over 150 years, Sherwin-Williams has been committed
to developing and delivering innovative protective and marine
coating solutions, unparalleled service and expert specification
support to its customers. Continuous research and development
has led to developing a range of high performance paints
delivering a number of key benefi ts:
• high resistant to abrasion and corrosion
• high solids, quick-drying coatings
• ease of applications.
Global reach with local expertise
Our global footprint allows us to supply diverse ranges of
protective coatings to all types of power applications anywhere
in the world, helping you to protect your investment from the
world’s harshest environments.
For over 150 years, Sherwin-Williams has been committed
to developing and delivering innovative protective and marine
coating solutions, unparalleled service and expert specification
support to its customers.
With 12 factories, nine research and development departments
in Europe and operations in over 120 countries globally. Our
comprehensive product offering, unique product knowledge and
extensive range of approvals enable us to provide you with the
complete, durable coatings solutions for all types of applications
and industries to meet your needs.
Technical Support
We aim to provide the highest levels of service in selecting,
specifying and applying nuclear power plants. Please do
hesitate to contact your local representative to discuss any
individual needs for your project. We will support contractors
and clients on a regular basis from specifi cation right through to
implementation.
All our technicians have been certifi ed by recognized bodies
(FROSIO/ICORR/NACE/DATR) and can take action on site
as required.
Expertise and Innovation
6 Energy: EDF coatings solutions for the nuclear power industry
EDF specifi cation
Under the EDF specifi cation, all systems (level 1.2 and 3) need to undergo performance testing to prove specifi ed fi tness for purpose as well as fi re testing (fl ame spread, smoke formation).
Level 1and 2 systems need to pass decontamination testing. For level 1 additional testing is required:
cycle testing with radiation and heat exposure as design basis accident (DBA) tests.
EDF coding system
PERFORMANCE LEVEL
PIC PED
PID PEC
PIB PEB
PIA PEA
HIGH
INTERIOR EXTERIOR
HIGH
LOW LOW
Coating function Indoor coatings Outdoor coatings
PIA PIB PIC PID PIE PIF PIG PEA PEB PEC PED
EIA EIB - EID EIE EIF EIG EEA EEB EEC -
Iron bearing metal substrates
Anti-corrosion for cold surface: t<60°C
• product delivered uncoated
• automatically manufactured product shot-blasted and painted**
• deckings
Anti-corrosion for hot surface: 60°C < T < 120°C
Anti-corrosion for very hot surface: t< 120°C
Fire protection*
Anti-condensationon
For special protection (1)
100 100 100 100 100 100 100 200 200 200 200
101 101 101 101 101 101 101 201 201 201 201
103 103 103 103 103 103 103 203 203 203 203
104 104 104 104 104 104 104 204 204 204 204
105 105 105 105 105 105 105 2005 205 205 205
106 106 - 106 106 - - 206 206 206 206
107 107 - - 107 - - - - - -
- 108 - 108 108 - - 208 208 208 208
Iron-bearing or non iron-bearing metal
substrates that have undergone a treatment
Protection for cold surface t< 60°C
• electrogalvanized
• galvanized
• zinc metallized
• zinc- aluminum metallized
• copper
Protection for hot surface: 60°C < T < 120°C
• galvanized
• zinc metallized
• zinc-aluminum metallized
• copper
Fire protection*
Anti-condensation
For unlisted surfaces (2)
119 119 119 119 119 119 119 219 219 219 219
120 120 120 120 120 120 120 220 220 220 220
121 121 121 121 121 121 121 221 221 221 221
122 122 - 122 122 122 122 222 222 222 222
123 123 - 123 123 123 123 223 223 223 223
124 124 124 124 124 124 124 224 224 224 224
125 125 125 125 125 125 125 225 225 225 225
126 126 - 126 126 126 126 226 226 226 226
127 127 - 127 127 127 127 227 227 227 227
128 128 - 128 128 - - 228 228 228 228
129 129 - - 129 - - - - - -
130 130 130 130 130 130 130 230 230 230 230
* Except for series E (maintenance) systematic returning to fi rst application.
** The primer can be preserved if it is an integral part of the system to be implemented and if the conditions of application
have been respected.
(1) Protection not specifi ed elsewhere. The qualifi cation of the required protection and the defi nition of the necessary
qualifying tests are added to the system coding.
(2) The designation of the surface type and the functions required of the coating and the defi nition of the necessary
qualifying tests are added to the system coding.
AREA
A/B/C/D/X
(NUCLEAR ISLAND STORAGE)
SUBSTRATE
I = INTERIOR
E = EXTERIOR
L = LIQUID (IMMERSION)
P= NEW
E = MAINTENANCE
P I C
SERIES
GROUP
7Energy: EDF coatings solutions for the nuclear power industry
Our comprehensive systems cover protection for scenarios:
• reactor PIC systems
• nuclear fuel storage PID systems
• out door PED systems
• turbine hall PIA/PIB systems.
System guidance
8 Energy: EDF coatings solutions for the nuclear power industry
Indoor systems for metallic substrates
FNP Paint system Thickness System code according
CCTR n°91.C.031.07
September 2016
Substrate description
370 Monocouche 4415
Monocouche 4415 Ferrosoter PC
40 μm
40 μm
40 μm
PIA 100 101
EIA 100
Ferrous metallic substrate
- Anticorrosion for cold surface:
T ≤ 60 °C
• Product delivered “raw” (100)
• Shot blasted and painted products fabricated automatically (101)
380 Epodux Primer 61-134 v01
Epodux Primer 61-134 v01
Polystria v01
40 μm
40 μm
40 μm
PIA 100 101 103 104
119 120 121 122 123
124 125 126 127
PIB 100 101 103 104
119 120 121 122 123
124 125 126 127
PID 100 101 103 104
119 120 121 122 123
124 125 126 127
EIA 100 103 104 119
125 126 127
Ferrous metallic substrates
- Anticorrosion for cold surface:
T ≤ 60 °C
• Product delivered “raw” (100)
• Shot blasted and painted products fabricated automatically (101)
• Sheet metal (103)
Anticorrosion for hot surface :
60 °C ≤ T ≤ 120 °C (104)
Treated non-ferrous or ferrous metallic substrates
Protection for cold surface: T ≤ 60 °C:
• Zinc plated (119)
• Galvanized (120)
• Metallised with zinc (121)
• Metallised with zinc-aluminium (122)
• Copper (123)
- Protection for hot surface : 60 °C < T ≤ 120 °C :
• Galvanized (124)
• Metallised with zinc (125)
• Metallised with zinc-aluminium (126)
• Copper (127)
381 Epodux Primer 61-134 v01 Epodux
Primer 61-134 v01 Ferrosoter PC
40 μm
40 μm
40 μm
PIA 100 101 120 121
122
EIA 100 120 121 122
Ferrous metallic substrates
- Anticorrosion for cold surface:
T ≤ 60 °C
• Product delivered “raw” (100)
• Shot blasted and painted products fabricated automatically (101)
Treated non-ferrous or ferrous metallic substrates
- Protection for cold surface: T ≤ 60 °C:
• Galvanized (120)
• Metallised with zinc (121)
• Metallised with zinc-aluminium (122)
395 Epodux Primer 61-134 v01 Epodux
Primer 61-134 v01 Epodux “O”
82-34
50 μm
50 μm
40 μm
PIA PIB PID 100 EIA EIB EID
100
Ferrous metallic substrate
- Anticorrosion for cold surface: T ≤ 60 °C
• Product delivered “raw” (100)
1038 Epodux 292
Epodux 292
Epodux 294
45 μm
45 μm
50 μm
PIA 100 101 103 104
PIB 100 101 103 104
PID 100 101 103 104
EIA 100 103 104
EIB 100 103 104
EID 100 103 104
PIC 100 REP
Ferrous metallic substrates
- Anticorrosion for cold surface:
T ≤ 60 °C
• Product delivered “raw” (100)
• Shot blasted and painted products fabricated automatically (101)
• Sheet metal (103)
- Anticorrosion for hot surface: 60°C <T ≤ 120°C (104)
Systems
9Energy: EDF coatings solutions for the nuclear power industry
Outdoor systems for metallic substrates
FNP Paint system Thickness System code according
CCTR n°91.C.031.07
September 2016
Substrate description
1022 Ferrocote Ferrocote Polystria v01 80 μm
80 μm
40 μm
PEA 200 201 203 204
PEB 200 201 203 204
EEA 200 201 203 204
EEB 200 201 203 204
Ferrous metallic substrates
- Anticorrosion for cold surface:
T ≤ 60 °C
• Product delivered “raw” (200)
• Shot blasted and painted products fabricated automatically (201)
• Sheet metal (203)
- Anticorrosion for hot surface : 60°C < T ≤ 120 °C (204)
1062 Ferrocote Ferrocote Polystria v01 120 μm
120 μm
40 μm
PEA PEB PEC 200 201 203
204
EEA EEB EEC 200 203 204
Ferrous metallic substrates
- Anticorrosion for cold surface:
T ≤ 60 °C
• Product delivered “raw” (200)
• Shot blasted and painted products fabricated automatically (201)
• Sheet metal (203)
- Anticorrosion for hot surface : 60°C < T ≤ 120 °C (204)
1063 Epodux Zinc 62-208
Epodux Primer 61-134 v01
Polystria v01
50 μm
50 μm
50 μm
PEA PEB PEC 220 224
EEA EEB EEC 220 224
Treated non ferrous or ferrous metallic substrates
- Protection for cold surface: T ≤ 60 °C:
• Galvanized (220)
- Protection for hot surface : 60°C < T ≤ 120 °C
• Galvanised (224)
1064 Primodux H Primodux H Polystria v01 90 μm
90 μm
50 μm
PEA PEB PEC 200 201 203
204
Ferrous metallic substrates
- Anticorrosion for cold surface:
T ≤ 60 °C
• Product delivered “raw” (200)
• Shot blasted and painted products fabricated automatically (201)
• Sheet metal (203)
- Anticorrosion for hot surface : 60°C < T ≤ 120 °C (204)
1065 Epodux IM 209 Polystria v01 150 μm
50 μm
PED 220 224
PID 100 PEC 200
Ferrous metallic substrates
- Anticorrosion for cold surface:
T ≤ 60 °C
• Product delivered “raw” (100 et 200)
Treated non ferrous or ferrous metallic substrates
- Protection for cold surface: T ≤ 60 °C:
• Galvanized (220)
- Protection for hot surface : 60°C < T ≤ 120 °C
• Galvanised (224)
1068 Primodux H Primodux H Polystria v01 150 μm
150 μm
50 μm
PEA PEB PEC 200 203 204
EEA EEB EEC 200 203 204
PED 203 204
PED 200
Ferrous metallic substrates
- Anticorrosion for cold surface: T ≤ 60 °C
• Product delivered “raw” (200)
• Sheet metal (203)
- Anticorrosion for hot surface : 60°C < T ≤ 120 °C (204)
Systems
10 Energy: EDF coatings solutions for the nuclear power industry
Systems for concrete fl oors
FNP Paint system Thickness System code according
CCTR n°91.C.031.07
September 2016
Substrate description
360A Epodux Enduit “O” 82-32 Epodux
“O” 82-34
Epodux “O” 82-34
752 g/m²
60 μm
60 μm
PIA PID 155
EIA EID 155
Cement-based substrate
- for fl oors
• Low traffi c coating (thin) (155)
360B Epodux Enduit “O” 82-32 Airless
Epodux Enduit “O” 82-32 Airless
Epodux “O” 82-34
Epodux “O” 82-34
415 g/m²
415 g/m²
60 μm
60 μm
PIA PID 155
EIA EID 155
Cement-based substrate
- for fl oors
• Low traffi c coating (thin) (155)
360C Epodux Enduit “O” 82-32 Epodux
Enduit “O” 82-32 Epodux “O” 82-34
Epodux “O” 82-34
376 g/m²
376 g/m²
60 μm
60 μm
PIA PID 155
EIA EID 155
Cement-based substrate
- for fl oors
• Low traffi c coating (thin) (155)
376 Epodux “O” 82-34
Epodux “O” 82-34
40 μm
40 μm
PIA PIB PID 154 PIA PIB 151
152 155
PID 152
EIA EIB 151 152 155
EID 152
Cement-based substrate
- for walls and ceilings
• Smooth fi nish (151)
• Textured fi nish (dust protection) (152)
- for fl oors
• Simply dust resistant (154)
• Low traffi c coating (thin) (155)
1082 Striaform (optionnel) Résine
Multicouche v01 Striasol 500
SP v02
0 à 5000 μm
360 μm
500 μm
PIA PIB PID 156 EIA EIB EID
156
Cement-based substrate
- for fl oors
• Medium traffi c coating (156).
1083 Striaform (optionnel) Résine
Multicouche v01 Striasol 2000
NF0
0 à 5000 μm
360 μm
3215 μm
PIA PIB PID 157 EIA EIB EID
157
Cement-based substrate
- for fl oors
• Heavy traffi c coating (157).
1085 Striaform (optionnel) Résine
Multicouche v01
Striasol 1500
0 à 5000 μm
350 mm
1200 μm
PIA PIB PID 156 EIA EIB EID
156
Cement-based substrate
- for fl oors
• Medium traffi c coating (156).
Systems for concrete walls and ceilings
FNP Paint system Thickness System code according
CCTR n°91.C.031.07
September 2016
Substrate description
376 Epodux “O” 82-34
Epodux “O” 82-34
40 μm
40 μm
PIA PIB PID 154 PIA PIB 151
152 155
PID 152
EIA EIB 151 152 155
EID 152
Cement-based substrate
- for walls and ceiling
• Smooth fi nish (151)
• Textured fi nish (dust protection) (152)
- for fl oors
• Simply dust resistant (154)
• Low traffi c coating (thin) (155)
384 Epodux Enduit “O” 82-32 Airless ou
Epodux Enduit “O” 82-32 Epodux
“O” 82-34
Epodux “O” 82-34
600 g/m²
40 μm
40 μm
PIA PIB PID 151 EIA EIB EID
151
Cement-based substrate
- for walls and ceiling
• Smooth fi nish (151)
Systems
11Energy: EDF coatings solutions for the nuclear power industry
Systems for metallic substrates in contact with the ground or a liquid
FNP Paint system Thickness System code according
CCTR n°91.C.031.07
September 2016
Substrate description
1086 Epodux 292
Epodur NV 75-25
50 μm
600 μm
PLB PLF PLG PLH 300 301
303 304
PLA PLD 300 301 304
PLE 300 301 303
ELB ELF ELG ELH 300 301
303 304
ELA ELD 300 301 304
ELE 300 301 30
Ferrous metallic substrates
- Anticorrosion for cold surface: T ≤ 50 ° C
• Product delivered “raw”(300)
• Shot blasted and painted products fabricated automatically ((PGP) 301)
• Sheet metal (303)
- Anticorrosion for hot surface: 50°C <T ≤ 80°C (304)
PLA ELA: Ground (buried surface) PLB ELB: Water
PLD ELD: Demineralized water PLE ELE: Seawater
PLF ELF: Hydrocarbons - oils PLG ELG: Acids
PLH ELH: Bases
1094 Epodux IM 209
Epodux IM 209
Epodux IM 209
50 μm
250 μm
250 μm
PLA PLD ELA ELD 300 301
PLB PLE ELB ELE 300 301
303
PLB PLE ELB ELE 302 (except
heat exchanger and
condenser)
PLF ELF 300 301 303
Ferrous metallic substrates
- Anticorrosion for cold surface: T ≤ 50 ° C
• Product delivered “raw”(300)
• Shot blasted and painted products fabricated automatically ((PGP) 301)
• High-speed liquid material in suspension (302)
• Sheet metal (303)
PLA ELA: Ground (buried surface) PLB ELB: Water
PLD ELD: Demineralized water PLE ELE: Seawater
PLF ELF: Hydrocarbons - oils
1095 Epodux IM 209
Epodux IM 209
50 μm
500 μm
PLA PLD ELA ELD 300 301
PLB PLE ELB ELE 300 301
303
PLB PLE ELB ELE 302 (except
heat exchanger and
condenser)
PLF ELF 300 301 303
Ferrous metallic substrates
- Anticorrosion for cold surface: T ≤ 50 ° C
• Product delivered “raw”(300)
• Shot blasted and painted products fabricated automatically ((PGP) 301)
• High-speed liquid material in suspension (302)
• Sheet metal (303)
PLA ELA: Ground (buried surface) PLB ELB: Water
PLD ELD: Demineralized water PLE ELE: Seawater
PLF ELF: Hydrocarbons - oils
Systems
Systems for casings concrete
FNP Paint system Thickness System code according
CCTR n°91.C.031.07
September 2016
Substrate description
1073 Biotank Bio tank 773 g/m²
500 μm
PLC 350 Cement-based substrate
- Typical protection: permanent contact (350)
PLC: Drinking water
1087 Résine Multicouche v01 Striaform
(réparation) Epodur NV 75-25
400 μm repair
600 μm
PLA PLD 350
PLB PLE PLF 349 350
PLG PLH 349
ELA ELD 350
ELB ELE ELF 349 350
ELG ELH 349
Cement-based substrate
Typical protection (not watertight) : tempory contact (349)
Typical protection (not watertight) : permanent contact (350)
PLA ELA: Ground (buried surface) PLB ELB: Water
PLD ELD: Demineralized water PLE ELE: Seawater
PLF ELF: Hydrocarbons - oils PLG ELG: Acids
PLH ELH: Bases
12 Energy: EDF coatings solutions for the nuclear power industry
Systems for hydraulic
FNP Paint system Thickness System code according
CCTR n°91.C.031.07
September 2016
Substrate description
1012 Hydrofl ash v01
Hydrofl ash v01
225 μm
225 μm
PED 200
Hydraulic (C5-I)
Ferrous metallic substrates
- Anticorrosion for cold surface: T ≤ 60 °C
• Product delivered “raw” (200)
1013 Ferrocote Ferrocote Polystria v01 195 μm
195 μm
60 μm
PED 200 204
Hydraulic (C5-I)
Ferrous metallic substrates
- Anticorrosion for cold surface: T ≤ 60 °C
• Product delivered “raw” (200)
- Anticorrosion for hot surface: 60°C < t ≤ 120°C (204)
1036 Epodux IM 209
Epodux IM 209
100 μm
350 μm
PED 200 204
Hydraulic (C5-I) (en milieu
abrité)
Ferrous metallic substrates
- Anticorrosion for cold surface: T ≤ 60 °C
• Product delivered “raw” (200)
- Anticorrosion for hot surface: 60°C < t ≤ 120°C (204)
1050 Epodux IM 209
Epodux IM 209 Polystria v01
195 μm
195 μm
60 μm
PED 200 204
Hydraulic (C5-I) (en milieu
aérien)
Ferrous metallic substrates
- Anticorrosion for cold surface: T ≤ 60 °C
• Product delivered “raw” (200)
- Anticorrosion for hot surface: 60°C < t ≤ 120°C (204)
1054 Primodux H Epodux IM 209
Epodux IM 209
50 μm
250 μm
250 μm
HCC HCG HCB HAC HAG HAB
HNC HNG HMC HMG HMB 600
Ferrous metallic substrates T ≤ 60°C
• Product delivered “raw” with preparation Sa 2½ (600)
1065 Epodux IM 209 Polystria v01 150 μm
50 μm
PED 220 224
PID 100 PEC 200
Ferrous metallic substrates
- Anticorrosion for cold surface:
T ≤ 60 °C
• Product delivered “raw” (100 et 200)
Treated non ferrous or ferrous metallic substrates
- Protection for cold surface: T ≤ 60 °C:
• Galvanized (220)
- Protection for hot surface : 60°C < T ≤ 120 °C
• Galvanised (224)
1066 Epodux IM 209
Epodux IM 209
Epodux IM 209
50 μm
250 μm
250 μm
HCC HCG HCB HAC HAG HAB
HNC HNG
HMC HMG HMB 600 621
Ferrous metallic substrates (T ≤ 60°C)
• Product delivered “raw” with preparation Sa 2 ½ (600)
Treated non ferrous or ferrous metallic substrates (T≤60°C)
• Metallised with zinc or zinc aluminum (621)
1067 Epodux IM 209
Epodux IM 209
50 μm
500 μm
HCC HCG HCB HAC HAG HAB
HNC HNG
HMC HMG HMB 600 621
Ferrous metallic substrates (T ≤ 60°C)
Product delivered “raw” with preparation Sa 2 ½ (600)
• Treated non ferrous or ferrous metallic substrates (T≤60°C)
• Metallised with zinc or zinc tailor-made (621)
1072 Epodux IM 209
Epodux IM 209 Polystria v01
50 μm
350 μm
50 μm
PED 221 222 Treated non ferrous or ferrous metallic substrates
- Protection for cold surface: T ≤ 60 °C
• Metallised with zinc (221)
• Metallised with zinc-aluminium (222)
Systems
13Energy: EDF coatings solutions for the nuclear power industry
Nuclear references
Nuclear power station FNP Application substrate Location of work
Gravelines, France 360 Concrete fl oor Engine room/various room
376 Engine room
1040 Electric locks
398 Controlled area/command room
1040 Controlled area
376 Concrete wall engine room
384 Controlled area
370 Metallic inside Metalic bodyguard/engine
380 Piping in a controlled area
381 Fireplace
1038 Engine in a controlled area
1062 Metallic outside Exterior carpentry
1063 Pumping station
1064 Pumping station
1013 Portal building reactor
1036 Exterior carpentry
1050 Pumping station/tertiary circuit
1054 Pumping station
Bugey, France 360 Concrete fl oor Engine room/various room
376 Engine room/concrete base
1040 Used nuclear area
398 Fuel area
1040 Controlled area
376 Concrete wall Engine room/fuel area
384 Controlled area
370 Metallic inside Metalic bodyguard/engine
380 Piping in a controlled area
381 Frame and engine
1038 Waste treatment plant
1062 Metallic outside Exterior carpentry
1063 Pumping station
1064 Pumping station
1013 Portal building reactor
1036 Exterior carpentry
1050 Pumping station/tertiary circuit
1054 Pumping station
14 Energy: EDF coatings solutions for the nuclear power industry
Nuclear references
Nuclear power station FNP Application substrate Location of work
Blayais, France 360 Concrete fl oor Machine room access stairs
376 Concrete base
1040 General store
398 Controlled area
1040 Steam generator building
376 Concrete wall Engine room/fuel area
384 Controlled area/demined rooms
370 Metallic inside Metalic bodyguard/engine
380 Piping in a controlled area
381 Frame and engine
1038 Waste treatment plant
1062 Metallic outside Exterior carpentry
1063 Outdoor crane
1064 Pumping station
1013 Portal building reactor
1036 Exterior carpentry/local chemistry
1050 Pumping station/tertiary circuit
1054 Pumping station
Cruas, France 360 Concrete fl oor Machine room
376 Concrete base/traffi c way
1040 Nuclear auxiliary building
398 Controlled area
1040 Controlled area/demined rooms
376 Concrete wall Engine room/fuel area
384 Controlled area
370 Metallic inside Chemistry tanker outdoor
380 Piping in a controlled area
381 Frame and engine
1038 Waste treatment plant
1062 Metallic outside Exterior carpentry
1063 Chemistry tanker outdoor
1064 Pumping station
1013 Portal building reactor
1036 Exterior carpentry/local chemistry
1050 Pumping station/tertiary circuit
1054 Pumping station
15Energy: EDF coatings solutions for the nuclear power industry
Tricastin, France 360 Concrete fl oor Traffi c way/corridor
376 concrete base/engine room
1040 General store
398 Controlled area
1040 Controlled area/demined rooms
376 Concrete wall engine room/fuel area
384 demined rooms
370 Metallic inside Metalic bodyguard/engine
380 Piping in controlled area/decking
381 Frame and engine
1038 Waste treatment plant
1062 Metallic outside Exterior carpentry
1063 Outdoor crane
1064 Pumping station
1013 Portal building reactor
1036 Exterior carpentry/local chemistry
1050 Pumping station/tertiary circuit
1054 Pumping station
Nuclear references
Nuclear power station FNP Application substrate Location of work
Golfech, France 360 Concrete fl oor Machine room access stairs
376 concrete base
1040 General store
398 Controlled area/command room
1040 Controlled area/demined rooms
376 Concrete wall Engine room/fuel area
384 Controlled area/demined rooms
370 Metallic inside Metalic bodyguard/engine
380 Piping in a controlled area
381 Frame and engine
1038 Waste treatment plant
1062 Metallic outside Exterior carpentry
1063 Outdoor crane
1064 Pumping station
1013 Portal building reactor
1036 Exterior carpentry/local chemistry
1050 Pumping station/tertiary circuit
1054 Pumping station
16 Energy: EDF coatings solutions for the nuclear power industry
Nuclear references
Nuclear power station FNP Application substrate Location of work
Dampierre, France 360 Concrete fl oor Machine room access stairs
376 concrete base
1040 Steam generator building
398 Controlled area
1040 Controlled area/demined rooms
376 Concrete wall Engine room/fuel area
384 Controlled area/demined rooms
370 Metallic inside Metalic bodyguard/engine
380 Piping in a controlled area
381 Frame and engine
1038 Casement VVP
1062 Metallic outside Exterior carpentry
1063 Outdoor crane
1064 Pumping station
1013 Portal building reactor
1036 Exterior carpentry/local chemistry
1050 Pumping station/tertiary circuit
1054 Pumping station
Chinon, France 360 Concrete fl oor Floor demarcation
376 Concrete base
1040 General store
398 Controlled area
1040 Controlled area/demined rooms
376 Concrete wall Engine room
384 Controlled area/demined rooms
370 Metallic inside Metalic bodyguard/engine
380 Decking
381 Frame and engine
1038 Workshop
1062 Metallic outside Exterior carpentry
1063 Metal fl oor
1064 Pumping station
1013 Portal building reactor
1036 Exterior carpentry/local chemistry
1050 Pumping station/tertiary circuit
1054 Cooling system
17Energy: EDF coatings solutions for the nuclear power industry
18 Energy: EDF coatings solutions for the nuclear power industry
19Energy: EDF coatings solutions for the nuclear power industry
Sherwin-WilliamsYour asset protection partner
TM = is a registered trademark in one or more countries.
To learn more, contact us
Europe & Africa: +44 (0)1204 556420 [email protected]
Middle East & India: +971 4 8840200 [email protected]
North America: +1 800 524 5979
Asia: +8 621 5158 7798
www.protectiveemea.sherwin-williams.com
©2019 The Sherwin-Williams CompanyProtective & Marine Coatings 9/19 EMEA0212/V01
A complete line of products. Market expertise. On time distribution. What else would you expect from a world leader in protective coatings, linings, and fi re protection?
It starts with a complete line of time tested, high performance products and some of the
most innovative and greenest technologies in the coatings industry. We know that it takes
more than product alone to be a world leader in protective coatings and linings, and so do
the customers that rely on us every day as we help them protect their business.
That’s where over 150 years of coatings industry experience comes in. Add to that a
FROSIO/ICORR/NACE/DATR trained workforce with vast experience in corrosion control and
the market specifi c knowledge that our experts provide to evaluate, recommend and deliver
the highest performance coatings and linings that protect our customers’ assets.
Leave nothing to chance. Your single source of supply. Sherwin-Williams.