Energy efficiency monitoring in Mexico by indicators … · Energy efficiency monitoring in Mexico...

11
Energy efficiency monitoring in Mexico by indicators Workshop on end-use data and energy efficiency metrics Juan Ignacio Navarrete Barbosa Deputy Director General for Policies and Programs in Energy Efficiency December 2016

Transcript of Energy efficiency monitoring in Mexico by indicators … · Energy efficiency monitoring in Mexico...

Energy efficiency monitoring in

Mexico by indicators

Workshop on end-use data and energy efficiency metrics

Juan Ignacio Navarrete Barbosa

Deputy Director General for Policies and

Programs in Energy Efficiency

December 2016

What is the motivation in CONUEE on EE

Indicators?

• National Commision for efficente use of energy (CONUEE)

• Some requirements about monitoring by legal framework:

Developing energy efficiency indicators by sectors and end-use

Making benchmark between different countries regarding Mexico by sectors

To assess yearly the PRONASE (Mexican NEEAP)

• Others motivation:

Monitoring national and current policies (30 standards, programs, etc.)

Starting to assess new challenges and EE policies considering in LTE

Improve and strengthen the relationship with international cooperation

Economic Comission for Latin America and the Caribbean (ECLAC) International Partnership for Energy Efficiency Cooperation (IPEEC) French cooperation (ADEME and AFD) International Energy Agency (IEA)

More than 27 years working on EE actions

Technical body in change to promoting EE in Mexico by Law

Law for sustainable use of energy in 2008 (LASE) Energy transition law in 2015 (LTE)

BIEE Project leading by ECLAC-UN

This project is based on the European Union program,

ODYSSEE-MURE

BIEE Project was released in 2011 by ECLAC, it has

sponsored by GIZ, and technical supported by ADEME

and ENERDATA.

Mexico in one of 19 countries in Latin America has

been participating in this Project. Mexico has been

participating since April 2013.

ECLAC´s tool allowed to Mexico obtain information for

monitoring policies with EE indicators.

To develop local capabilities in CONUEE.

To have and participate in a Latin american

benchmark tool.

Interactive tool on line in BIEE Project

Macroeconomic

Energy Industrial

Transport Residential

Commercial&

Services Agriculture

Conuee has integrated a team for collecting,

processing data and integration EEI (In partial

time).

It has been processed 5,095 times statistical series,

near 80% belongs to the energy and economy

information in 7 sectors.

Analyzed times series from 1990 to 2014.

CONUEE has strengthened the relationships

with the more energy intensive industrial

associations (Steel, Chemical, Paper and Pulp,

Cement, Sugar and Mining)

BIEE tool has allowed to obtain more than 60

energy efficiency indicators.

Now, CONUEE is finishing our first national report

on EEI, incluiding nexus water-energy chapter.

Main achievements with BIEE Project

Agreement for French-Mexican cooperation

Strengthen cooperation in aeras of energy efficiency monitoring between France and Mexico: I. Implementation of surveys on end-use consumption in

selected sectors.

II. Development, calculation and analisys on advanced energy efficiency indicators

III. Methodologies for monitoring the NEEAP

IV. Development of a national interactive databese on the energy demand and EEI.

V. Implementation on an end-use long-term energy demand forecast model

VI. Encourage dialogue between energy models implementation.

How is it going our cooperation in end-uses?

What about space cooling in households?

Mexico started collecting different public information: I. Pupulation by state from CONAPO

II. Dwellings with AC each two years from INEGI, but just national representative

III. Stock of AC in households by state and representative, but disruption in the period

IV. Number of users and electricity consumption by tarif and state from CFE, monthly

V. CONUEE developed degree-days tool.

VI. Temperatures (maximum, minimum and medium) and precipitation level by state,

monthly from SMN

Methodology for the estimation of space cooling

Cooling degree-day

by state

Electricity consumption

by state

Trend analysis by states

Hot Summer Zone Tropical Zone Mild Zone

Seasonal behavior

Share space cooling by difference

0

500,000

1,000,000

1,500,000

2,000,000

2,500,000

3,000,000

3,500,000

1 2 3 4 5 6 7 8 9 10 11 12

Hot summer zone

0

200,000

400,000

600,000

800,000

1,000,000

1,200,000

1,400,000

1 2 3 4 5 6 7 8 9 10 11 12

Tropical zone

0

200,000

400,000

600,000

800,000

1,000,000

1,200,000

1,400,000

1,600,000

1,800,000

2,000,000

1 2 3 4 5 6 7 8 9 10 11 12

Mild zone

Electricity consumption (MWh) and share estimated for

space cooling by zone

32.3%

22.5% 3.1%

%SC

Before (official sample)

0

2

4

6

8

10

12

14

16

1990 1995 2000 2005 2010

%

Years

% of households with air conditioners

0

2

4

6

8

10

12

14

16

1992 1994 1996 1998 2000 2002 2004 2006 2008 2010 2012 2014

%

Years

% of households with air conditioners

After (soften serie for EEI)

Saturation rate for air conditioner

www.conuee.gob.mx

Twitter: @conuee_mx

http://enerweb.mx/

[email protected]

Thanks¡

Finally…

I thought that we had good data six month ago,

now i am sure that we have more and better

energy efficiency indicators