Enable the smart factory with IO Link
-
Upload
dan-rossek -
Category
Engineering
-
view
132 -
download
6
Transcript of Enable the smart factory with IO Link
![Page 1: Enable the smart factory with IO Link](https://reader036.fdocuments.net/reader036/viewer/2022081421/5881f0331a28abb4748b4945/html5/thumbnails/1.jpg)
Enabling The Smart Factory with IO Link
OMRON
![Page 2: Enable the smart factory with IO Link](https://reader036.fdocuments.net/reader036/viewer/2022081421/5881f0331a28abb4748b4945/html5/thumbnails/2.jpg)
Smart Factories & IO LinkIO Link IntroductionUser BenefitsIO Link HardwareTechnical Information
![Page 3: Enable the smart factory with IO Link](https://reader036.fdocuments.net/reader036/viewer/2022081421/5881f0331a28abb4748b4945/html5/thumbnails/3.jpg)
Smart Factories & IO LinkHow IO link supports the smart factory concept Real time data collection from the
lowest level Communicate and escalate this
data for instant analysis in controller / IT
Automatically and instantaneously re-configurable
Supports flexible and customised production
Automatic fault alerts Monitor down to product level for
predictive / preventative maintenance
![Page 4: Enable the smart factory with IO Link](https://reader036.fdocuments.net/reader036/viewer/2022081421/5881f0331a28abb4748b4945/html5/thumbnails/4.jpg)
IO Link IntroductionWhat is IO Link?
Communication technology for sensors and actuators
Point-to-point communication 3-Wire connection Open vendor protocol IEC 61131-9 (international
standard)
Full communication
![Page 5: Enable the smart factory with IO Link](https://reader036.fdocuments.net/reader036/viewer/2022081421/5881f0331a28abb4748b4945/html5/thumbnails/5.jpg)
IO Link IntroductionWhat does IO Link do?
IO Link allows status information to be read from the device
Information beyond on/off status
Configuration parameters can be transferred to the sensor
configuration parameterscan be transferred
status information can be read
![Page 6: Enable the smart factory with IO Link](https://reader036.fdocuments.net/reader036/viewer/2022081421/5881f0331a28abb4748b4945/html5/thumbnails/6.jpg)
IO Link IntroductionIO Link Architecture
• on/off status• analogue values • status information• configuration parameters
Bidirectional accessDownload: Parameters and
optionsUpload: Process data and
diagnostics
![Page 7: Enable the smart factory with IO Link](https://reader036.fdocuments.net/reader036/viewer/2022081421/5881f0331a28abb4748b4945/html5/thumbnails/7.jpg)
IO Link User BenefitsKey Business Drivers
Reduce machine downtime Enable predictive / preventative
maintenance to reduce machine faults
Reduction in changeover time Enhanced machine commissioning
efficiency
![Page 8: Enable the smart factory with IO Link](https://reader036.fdocuments.net/reader036/viewer/2022081421/5881f0331a28abb4748b4945/html5/thumbnails/8.jpg)
IO Link User BenefitsEasy Machine Troubleshooting >> Reduce machine downtime Failed / error sensor detection Wire break or short circuit
detection Instantly identify the location of
the error Instantly identify the product
which has an error Fast device changeover through
automatic parameter download
![Page 9: Enable the smart factory with IO Link](https://reader036.fdocuments.net/reader036/viewer/2022081421/5881f0331a28abb4748b4945/html5/thumbnails/9.jpg)
IO Link User BenefitsLight Level Monitoring >> Predictive / Preventative Maintenance Dirt on a sensor causing
unstable measurements can be detected for preventative maintenance.
Misaligned sensor can be detected before operation failure
Operational time can be monitored for predictive maintenance
![Page 10: Enable the smart factory with IO Link](https://reader036.fdocuments.net/reader036/viewer/2022081421/5881f0331a28abb4748b4945/html5/thumbnails/10.jpg)
IO Link User BenefitsProximity Warning >> Predictive / Preventative Maintenance
Detect excessive proximity to the sensor via a dedicated status bit
Monitor when target is outside of stable detection area
Identify mechanical issues before they cause a machine fault
![Page 11: Enable the smart factory with IO Link](https://reader036.fdocuments.net/reader036/viewer/2022081421/5881f0331a28abb4748b4945/html5/thumbnails/11.jpg)
IO Link User BenefitsAutomatic Configuration>> Reduction in Machine Changeover Time
Configuration data can be sent to sensors automatically for machine changeover
Eliminating the need for manual intervention
Reducing the possibility of manual setting errors
Reducing the time & complexity of machine changeovers
![Page 12: Enable the smart factory with IO Link](https://reader036.fdocuments.net/reader036/viewer/2022081421/5881f0331a28abb4748b4945/html5/thumbnails/12.jpg)
IO Link User BenefitsI/O Check >> More Efficient Machine Commissioning
Automatic network IO check provides instant detection of incorrect sensor type or wiring errors
Guided information supports fast resolution to errors
![Page 13: Enable the smart factory with IO Link](https://reader036.fdocuments.net/reader036/viewer/2022081421/5881f0331a28abb4748b4945/html5/thumbnails/13.jpg)
IO Link User BenefitsBatch Configuration >> More Efficient Machine Commissioning
For serial machines all devices can be automatically configured from master program file
Eliminating the need to configure individual devices on each machine build
Reducing commissioning time of machinery
![Page 14: Enable the smart factory with IO Link](https://reader036.fdocuments.net/reader036/viewer/2022081421/5881f0331a28abb4748b4945/html5/thumbnails/14.jpg)
IO Link HardwareOverview
NX 4 Ch. Master GX IP67 8 Ch. EtherCat
Slave E3Z Photo Sensor E2E Inductive Sensor E2E-Q Inductive Sensor E3S-DC Colour Registration
Mark Sensor
![Page 15: Enable the smart factory with IO Link](https://reader036.fdocuments.net/reader036/viewer/2022081421/5881f0331a28abb4748b4945/html5/thumbnails/15.jpg)
IO Link Technical InformationIO Link Parameter List Example (Device Dependant)
Vendor Name Product Name Product Text Serial Number Hardware Version Firmware Version Device Status Output Logic
Timer Setting Instability Status Instability Threshold Sensitivity Level Teaching Level Potentiometer level Switch Value Operating Hours
Setting Method Proximity Warning RGB Data Device Error
![Page 16: Enable the smart factory with IO Link](https://reader036.fdocuments.net/reader036/viewer/2022081421/5881f0331a28abb4748b4945/html5/thumbnails/16.jpg)
IO Link Technical InformationSystem Configuration
SysmacStudioCX-Configurator-FDT
Photoelectric sensorProximity sensor・
・
・・
EtherCAT
EtherNet/IP
IO-Link MasterNX unit type IO-Link DeviceSysmacStudio
CX-Configurator-FDT
USB
NJ/NX-Series CPU unit
EtherCAT coupler unit
[Tool] Sysmac Studio: to set the IO-Link master CX-Configurator-FDT: to set the IO-Link devices
[File] ESI file: EtherCAT slave definition file IODD file: IO-Link device definition file *IO Device Description
ESI fileIODD file
ESI fileIODD file
Third party’s IO-Link devices
IO-Link MasterGX Unit type
Read/Write commands for the IO-Link devices - IOL_ReadObj - IOL_WriteObj
Color mark sensor
![Page 17: Enable the smart factory with IO Link](https://reader036.fdocuments.net/reader036/viewer/2022081421/5881f0331a28abb4748b4945/html5/thumbnails/17.jpg)
IO Link Technical InformationRead & Write Function Blocks (SYMAC Library)
Normal endNormal endProcessing
Read data size
Processing
Error endError ID
Error IDRead data
Error Type Error Type
Execution condition
Device portObject parameter
Execution retry setting
Read data
Execution condition
Device port
Object parameter
Execution retry settingWrite data
Write data size
![Page 18: Enable the smart factory with IO Link](https://reader036.fdocuments.net/reader036/viewer/2022081421/5881f0331a28abb4748b4945/html5/thumbnails/18.jpg)
IO Link Technical InformationSensor Configuration Via CX-ConfiguratorFDT
![Page 19: Enable the smart factory with IO Link](https://reader036.fdocuments.net/reader036/viewer/2022081421/5881f0331a28abb4748b4945/html5/thumbnails/19.jpg)
IO Link Technical InformationSensor Diagnostics Via CX-ConfiguratorFDT