THE FUTUREOF OUR PLANET DEPENDS ON WHETHER WESUCCEED IN REDUCING FOSSIL FUEL CONSUMPTIONAND USE RENEWABLE SOURCES
ADVANCED INDOOR COMFORT SYSTEMS
ECOLOGICAL AWARENESS
The best forms of renewable energy can never be exhausted: a battle that is being
fought on two fronts.
A A reduction in energy consumption thanks to
buildings with innovative insulation systems and
high efficiency installations.
TThe use of renewable, ecofriendly and free energy sources, which reduce our dependency
on fossil fuels.
Clivet has developed a complete indoor comfort
system designed for energy saving with high efficiency devices able to use renewable energy.
HeHeating, cooling, hot water and air quality in a single year round system.
SUSTAINABLE DEVELOPMENT
1
2
HydroelectricThermal
Renewable
Freeambientenergy
Fossil FuelsPrimaryEnergy (1)
102
(1) Can be used in its natural form(2) Conversion factor of 2.17 between electricity available to the network and primary energy used for its production.(3) Seasonal coefficient of performance
Energy102
PrimaryEnergy (2)
54,2
Electricenergy25
Renewableenergy75 SCOP(3) = 4,0
Average seasonal performance 98%
100
100
Primary energy consumption reduction of 47%CO2 emission reduction of 50%
CONVENTIONAL COMBUSTION
HEAT PUMPS
HEAT PUMPS USEINDIRECT SOLAR ENERGY
Over 75% of the energy used by heat pumps is free and unlimited because it comes from the sun and is stored
by the air, water and ground. UUsing just 25% electricity, it is raised to an optimum level for summer and
winter comfort.
The RES DIRECTIVE (Renewable Energy Sources) was approved on 23
April 2009 by the European Parliament,
acacknowledging ambient heat as a form of renewable energy. Heat
pumps make use of this renewable source, by using the heat contained
in the air, water and ground.
air
ground
water
75% 100%
25%
electricenergy
solarpanels
HEAT PUMP
replaceCO2 emissionsne dustother harmful substances
DIRECTSOLARENERGY
INDIRECTSOLARENERGY
heating
domestichot water
THE SUNPRIMARY ENERGY SOURCE
ELFOSYSTEM CAN ALSO USE DIRECT SOLAR
ENERGY
ELFOELFOSystem GAIA Edition is different from all the other heat pumps available on the market, as it can be connected directly to the solar thermal panels. In this case, hot domestic water is prproduced free of charge for
most of the year.
If combined with solar photovoltaic panels, it can lead to 100% autonomy
from fossil fuels.GAIA can even usesolar energy only.
+ direct solar energy
A single system for heating and cooling.
In winter, heat pumps take energy from outside and transfer it inside the
building.
IIn summer, heat pumps can reverse their
operation and transfer heat from inside the building to outside,
thereby providing indoor cooling.
GAIA= 100%
= 0%
HEAT PUMPSGUARANTEE YEAR ROUND COMFORT BY USING FROM 75% TO 100% RENEWABLE ENERGY
3
TEMPERATURE
HUMIDITY
AIR RENEWAL AND QUALITY
QUIET OPERATION
ELFOSystem controls and
manages ALL aspects of comfort:
Protect yourwellbeing
COMFORT
4
, 365 days a yearELFOSystemThe ideal climate is
available year round with ELFOSystem, making it time appear to stand still
in the home and providing relaxing
conditions that do not depend on depend on external
factors.
Odours and harmful elements build up when there is no air renewal in
the home. The recent trend of increasing thermal insulation in the home
makes controlled mechanical ambiemechanical ambient air renewal even more
important. Introducing outdoor air is not always good for your health and involves high energy costs. ELFOSystem rejects air ffrom inside the building and introduces puried outdoor air, using a recovery system that
employs the heat pump principle.
, fresh and clean airELFOSystem
5
GAIA Aria or GAIA AcquaHEATING/COOLING PRODUCTION
ELFOFresh2AIR QUALITY
ELFODistributionHEATING/COOLING DISTRIBUTION
ELFOControlSYSTEM CONTROL
THE FOUR ELEMENTS OF ELFOSystemProduction of the necessary heating and cooling energy for heating, cooling and domestic hot water production by means of high energy efficiency heat pumps.
Air renewal and purication in controlled conditions and heat recovery from the exhaust air.
Heat distribution through fan coils, radiant panels or radiators.
Temperature control by means of a comfort control unit able to activate the various system devices on the basis of the required level of comfort.
6
ELFOControlCentralised control
device
Heat distributionthrough fan coils,radiant panelsor radiators
GAIAThermal and cooling energy and domestic hot water production
Connection to solar thermal panels
ELFOFresh2
Air renewal and purication unit
ELFORoomRoom
terminal
ADD VALUE
ENERGY
7
The Earth receives
10.000times more solar energy than required by the whole of mankind
ELFOSystem uses this energy
ELFOSystem uses renewable energy from the sun, which is stored in the air, water and
ground or captured directly by solar thermal and photovoltaic
panels. All the system elements are designed to ensuensure that the building's
energy requirements are met as efficiently as possible, with the necessary quantities of
energy being distributed only where and when required.
It does not emit CO2, ne dust or other harmful substances. It reduces indirect CO2 emissions by over 50%. It does not use gas or other fossil fuels,
meaning that there is no risk of harmful substances escaping
ininto the environment.
to your house
renewable sources and efficient use
ADD VALUE The European Union has
issued a directive (2002/91/EC) which
requires buildings to have an energy efficiency
certicate, in consideration of primary energy. The value of an house also value of an house also
depends on this. ELFOSystem, with primary energy consumption of
50% lower than traditional boiler solutions in a comparable building, pepermits higher energy
ratings.ELFOSystem contributes to energy efficiency and the
value of the property, with a return on the investment being achieved within 3-4
years on average.
Specic primary energy for heating [kWh / m² per year]
GAIA + ELFOFresh2 + Photovoltaic
GAIA + ELFOFresh2
Boiler + ELFOFresh2
Boiler + Passive Recov. (ŋ=98%)
(ŋ=98%)
(ŋ=98%)
(ŋ=70%)
Boiler
Energy rating on the basis of national guidelinesThe example provided refers to:Location: Milan, Climate Zone E (2404 HDD). Single dwelling.Surface area: 200 m2; gross heated volume: 600 m3; external wall area: 440 m2; S/V ratio: 0.73 m-1Outer insulation: compliance with legal transmittance values (Uwalls: 0.34; Uroof: 0.30; Uoor: 0.33; Uwindows: 2.2 W/m2 K)
A+
A
B
C
0 kWh/m2
40,2 kWh/m2
56,8 kWh/m2
83,6 kWh/m2
D 104,2 kWh/m2
GAIA
The heat pumpthat replaces the boiler and air conditioner
RENEWABLE ENERGY UNIT FOR COMFORT IN THE HOMEPACKAGEDall the system components are housed inside the unit
BUILT-IN SYSTEM FOR THE RECOVERY OF SOLAR ENERGY FROM HEATING COLLECTORSfree domestic hot water production using the energy captured by the solar panels
BUILT-IN DOMESTIC HOT WATER PRODUCTIONwith 200-litre storage tank (Gaia Water only)
SYSTEM WITH THE BEST SEASONAL EFFICIENCY ON THE MARKETDC Inverter technology applied to the compressor, fan, system circulating pump and hot water circulating pump
HOT WATER PRODUCTION UP TO 60°C, OPERATION WITH OUTDOOR AIR TEMPERATURES OF DOWN TO -20°C
8
The heart of ELFOSystem
Gaia is automatically controlled, for full unit management.Hourly, daily and weekly programming.Summer and winter climate control settingsOn-board or remote installation elsewhere in the room.
Fully automatic
BOILER
HEAT PUMP
GAIA
-35%
-50%
POWER CONSUMPTION
Boiler Heatpump
GAIA
Gaia does away with the difficulties involved in choosing, installing and wiring in all the elements of a traditional system. Gaia
includes all the system components, tested by CliClivet, in a single unit.
Installation times are drastically reduced for a
quality end result.
The heating system occupies 60% less space than a bulky traditional
systems.
Electric control panelDomestic hot water thermostatic valveSystem lling assembly with pressure gaugesUUser side adjustable bypass valveUser side expansion vesselUser side and domestic hot water side safety valve
GAIA includes:
User side direct current inverter circulating pumpHot water recirculation direct current inverter circulating pump200-litre domestic hot water storage tankPPlate heat exchanger for solar thermal panelsSource side direct current inverter circulating pump
DC inverter compressorElectronic thermostatic valve
ELECTRONICMANAGEMENTAND CONTROLSECTION
STORAGEAND
DISTRIBUTIONHYDRAULIQUESECTION
DIRECTCURRENTINVERTERCOOLINGSECTION
Pre-assembled heating unit
Direct current inverter technology applied to the compressor, circulating pump and fan. The speed of the various devices can be modulated on the basis of the actual energy requirements, allowing for a further reduction in consumption and a signicant improvement in terms of seasonal efficiency.
Maximised seasonal efficiency
9
AriaGAIA
next to an external wall with lateral air exhaust.
with air delivery duct and exhaust far from the dwelling.
in the attic, with outdoor air intake through a window and lateral exhaust in the roof.
in the basement, with outdoor air intake through the fanlight and exhaust far from the dwelling, through an underground duct.
ENERGY EXCHANGER INSTALLED OUTSIDE ENERGY EXCHANGER INSTALLED INSIDE
ENERGY EXCHANGER
Free or ducted outlet
The outlet may be from any of the 4 sides
REFRIGERANT LINESThe maximum distance
between the two elements may be 20 metres, with a maximum difference in height of 15 metres.
GAIA Aria makes it possible to recover the energy found in the air, even when the outdoor temperature is very severe, down to -20°C. The direct current inverter radial fan ensures quiet operation, thanks to constant speed modulation on the basis of the operating conditions.The energy exchanger is very exible and can be installed in any system, either inside or outside the building.GAIAGAIA Aria and the energy exchanger are connected by means of a refrigerant connection, thereby preventing the risk of freezing.
“Air to Water”heat pumpIIn the Aria version, GAIA makes it possible to recover the thermal and cooling energy contained in the outdoor air.
10
GAIAAcqua
3
4
The low ground or groundwater temperature can be used free of charge to cool rooms in the home.
(1) cooled water delivery (system)(2) cooled water return (system)(3) user side heat exchanger(4) source side heat exchanger(5) sou(5) source water return(6) source water delivery(7) natural cooling plate heat exchanger(8) 3-way diverter valves(9) drain cocks
NATURAL COOLING FUNCTION (OPTIONAL)
GROUNDWATER ENERGY RECOVERY GROUND SOURCE ENERGY RECOVERY
Vertical collectors Horizontal collectors
GAIA Acqua is an extremely exible unit, sized to operate indifferently with geothermal probes or groundwater. The standard unit is tted with a source side direct current circulating pump, which automatically modulates the water ow on the basis of the temperature in order to optimise its performance.GAIA Acqua is equipped with the natural cooling function, which permits cooling without the need to activate the compressor.
“Water to water” or “glycol-treated water to water” heat pumpIIn the Acqua version, GAIA offers thermal and cooling energy recovery for all applications using groundwater, well water or geothermal sysystems.
11
ELFOFresh2
ACTIVE THERMODYNAMIC RECOVERYsummer and winter
UP TO 80% SATISFACTION OF THE BUILDING’S HEATING REQUIREMENT
ELECTRONIC FILTRATIONfor effective protection against even the most insidious pollutants (PM10, bacteria, pollen)
DEHUMIDIFICATIONin summer, ideal for combination with radiant cooling
FREE COOLING
New, clean and fresh airin the home
ELFOFresh2 is the innovative renewal and purication device for consistently clean air, at the right temperature and the right level of humidity, for total wellbeing in the home.ELFOFresh2 is a reliable and economical choice, because it is no longer necessary to lose heat when allowing fresh air into the home.
12
Air renewal, purication and energy production
During summer operation, ELFOFresh2 cools and dehumidies the renewal air, for greater comfort.Using ELFOFresh2 in cooling systems with oor, wall or ceiling radiant panels, means that a dehumidier is no longer required.
ELFOFresh2 rejects the stale air and introduces puried and climate controlled outdoor air. The harmful elements and smells present in the outdoor air are eliminated by the efficient ltration system. The electrostatic lter is easy to extract and can be fully restored through washing.
DehumidiesEliminates pollutants
ELFOFresh2 has a high efficiency cooling circuit, which absorbs the energy contained in the exhaust air and transfers it to the introduced air. In addition to recovering heat from the exhaust air, ELFOFresh2 also generates a basic amount of eneenergy, supplied to the building summer and winter. Thanks to its high energy efficiency index, ELFOFresh2 offers low energy
consumption, consuming even less if the energy is provided by the main generator (heat pump).
Introductionof clean air
into the room
Staleambient
air intake
External air inlet
Exhaust
GREATER COMFORT, GREATER WELLBEING
13
ELFORoom
UNIFORM TEMPERATURE
LOWER ENERGY CONSUMPTION
LESS NOISE
LARGE FILTER
Room terminalsELFODistribution
ELFORoom is an ingenious combination of design and
technology, ensuring a completely uniform temperature, constant air
ltration and imperceptiblenoise levels.
16
Consistently uniform temperature and lower energy consumption
Thanks to the continuous fan operation and the gradual speed variations, ELFORoom guarantees
constant air movement.TThe fan’s exclusive electric motor offers levels of absorption 80% below those of a traditional terminal of an equivalent
capacity. This permits consistent energy savings and also allows for a lower installed capacity.
The continuously running fan permits the appliance to operate at very low speeds, making the noise that it produces almost imperceptible.ELFORoom is equipped with a control system that permits the continuous adjustment of the number of fan revolutions to suit the system requirements.
Quiet operation
In addition to its complete and exible temperature control, ELFORoom also takes care of air quality. In fact, it is equipped with a large lter, easily accessible via the front panel, which ensures efficient air purication and makes it possible to reduce cleaning operations.
Cleans the air as it controls the temperature
17
ELFOControl
FULL SYSTEM CONTROL
HOURLY PROGRAMMING
COMFORT LEVEL CUSTOMISATION
ENERGY OPTIMISATION
TOUCHSCREEN DISPLAY
The future is alreadyat home
ELFOControl HOME is the “brain” behind your system, communicating with all the installed components. It checks the operating conditions of every single device and makes it possible to adjust the operation of the entire system from a single control point, on which the setting of all the desired parameters for the best levels of comfort depends.
18
ELFOControl controls and manages all the components in the system, distributing exactly the right amount of energy required, when and where it is required, thusthus ensuring maximum system efficiency. The management of every single element and the possibility to customise the settings, also makes it possible to obtain perfect lelevels of comfort for every requirement.
Communication with the room thermostats for temperature and humidity control
Underoor panel management(heating and cooling)
Dual temperature system management
Radiator and heated towel rail management
Zone valve switch
Circulating pump operation
ELFOControl MANAGES THE ENTIRE SYSTEM
19
SWITCH ON AND RELAXELFOELFOControl manages all the system elements: it automatically switches from summer to winter operation and supervises the whole system, without the need for any user intervention. The
ELFOControl touchscreen facilitates any operation: commands and settings are clear and easy to use. The main screen gives the user an
overview of the system component operating statuses and the comfort levels in the various rooms.
HOURLY PROGRAMMINGThe user is completely free to set the temperatures, humidity levels and operating times for every room in the home. Different rooms can be grouped into zones, setting the same comfort levels or
operating times.
COMFORT LEVEL CUSTOMISATIONFlexible room management, with the possibility to arrange rooms into 10 separate and autonomous zones. The user can give each
zone a specic name (i.e. “Kitchen”).
ENERGY OPTIMISATIONELFOControl makes it possible to dene the summer and winter
climate curve. The system thereby responds to outdoor conditions, calibrating itself on the basis of actual comfort requirements,
without wasting energy.
ENJOY THE COMFORT. LET ELFOControl DEAL WITH THE REST
20
Sizes 61 Radiators (C)Radiant panels (A) ELFO terminals (B)
Data referred to the following conditions:
Sizes 61
Air to waterheat pump
Location Heat. cap.(kW)
T °Cprojected
SCOPRadiant panels
SCOPTerminal units
SCOPRadiators
Cool. cap.(kW)
T °Cprojected
ESEERRadiant panels
ESEERTerminal units
Heating Cooling
Sizes 61
Sizes 61 Radiators (C)Radiant panels (A) ELFO terminals (B)
Data referred to the following conditions:
Water to waterheat pump
LocationSource Heat. cap.(kW)
T °Cprojected
SCOPRadiant panels
SCOPTerminal units
SCOPRadiators
Cool. cap. (kW)
T °Cprojected
ESEERRadiant panels
ESEERTerminal units
Heating Cooling
IMPORTANT!In order for the unit to remain in good working order,it is fundamental that the clearance spaces indicated bythe yellow areas are observed.
The above data refers to a standard unit.
Dimensions
Refrig. R-410A
Internal Inst.
ELFOControl
Herm. Rotative
Sizes Length (A) Depth (B) Height (C) Op. weight
200 80370436470
300 80370436475
500 103879242395
650 1038792423100
mmmmmmKg
Air supply
Air intake
Fresh air intake
Air exhaust
Data referred to the following conditions:All the data provided meets standard EN14511:2004 and refers to an available static pressure of 50 Pa.(1) Heating capacity/Total power input/COP; Outdoor air temperature 7°C W.B. / 6°C W.B., Exhaust air temperature 20°C D.B. / 15°C W.B.(2) Heating capacity/Total power input/COP; Outdoor air temperature -5°C W.B. / -5.4°C W.B., Exhaust air temperature 20°C D.B. / 15°C W.B.(3) Cooling capacity/Total power input/EER; Outdoor air temperature 30°C D.B. / 22°C W.B., Exhaust air temperature 27°C D.B. / 19°C W.B.(4) Cooling capacity/Total power input/EER; Outdoor air temperature 35°C D.B. / 24°C W.B., Exhaust air temperature 27°C D.B. / 19°C W.B.(5) (5) Capacity referring to operation in heating mode in the conditions in note (2). Important: the COP and EER already include the fan power input. This information is provided for the purposes of energy certication programmes. If this information is taken into account, the COP used must be the COP without the fan power input.(6) In locations where the outdoor air temperature falls below -5°C for a large number of hours per year, we recommend using the EHPCX accessory – ducted heater kit.(7) With RH = 40%; in parentheses, the limit at which a specic humidity of 10.5 g/kg is guaranteed for the air introduced into the room, with a 50% reduction in the maximum ow.(8)(8) The sound levels refer to units at full loads, in the rated testing conditions. The sound pressure level refers to a distance of 1 m from the outer surface of the unit.
Hc / Pi / COPHc / Pi / COPCc / Pi / EERCc / Pi / EERRated air owFan power inputMMaximum available static pressureOperating limit in heating modeOperating limit in cooling modeSound pressure levelPower supply
(1)(2)(3)(4)
(5)
(6)(7)(7)(8)
kWkWkWkWm3/hWPPa°C°C
dB(A)V/Ph/Hz
1.82 / 0.42 / 4.331.87 / 0.34 / 5.501.56 / 0.52 / 3.001.57 / 0.55 / 2.85
20040120120-1540 (38)39
2.31 / 0.57 / 4.052.36 / 0.41 / 5.752.10 / 0.67 / 3.132.02 / 0.70 / 2.89
30052120120-1540 (38)41
3.60 / 0.79 / 4.563.75 / 0.63 / 5.952.96 / 0.98 / 3.022.86 / 1.04 / 2.75
50090120120-1540 (38)44
5.02 / 1.21 / 4.155.12 / 0.94 / 5.453.96 / 1.40 / 2.833.86 / 1.45 / 2.66
650150120120-1540 (38)46
230/1/50
Sizes
Technical data200 300 500 650
Air renewal unit with active thermodynamic recovery
ELFOFresh2(CPAN-U 200 - 650)
32
33
ELFOFRESH2 300 OPERATING CRITERIA AND PERFORMANCE
The chart shows the following variables:
Outdoor Air Temperature (°C)
Heating withmodulating ventilation
Heating Cooling anddehumidication
Cooling anddehumidication withmodulating fan
Cooling anddehumidication
Cooling anddehumidication withmodulating fan
Heating
HEATING COOLING
HEATING COOLING
Free-Cooling
Heating withmodulating ventilation
Heating Heating Free-Cooling
Outdoor Air Temperature (°C)
(A) Coefficient of performance in heating mode (COP) and in cooling mode (EER): the relationship between the power delivered and the power input of the compressor, auxiliary circuit and fans, in consideration of an available head of 50 Pa;(B) Required ambient temperature (C) ELFOFresh2 delivery air temperature in the room (°C)
The chart shows the following variables:
(D) Heating/cooling performance (W)(E) Power input (W)(F) Internal relative humidity (g/kg)(G) External relative humidity (g/kg)(H) Delivery relative humidity (g/kg)(I) Introduced air ow (mch)
NOTE The performance charts for other sizes can be consulted in the technical report available from www.clivet.com.
IMPORTANT!In order for the unit to remain in good working order,it is fundamental that the clearance spaces indicated bythe yellow areas are observed.
Dimensions
ELFORoom IN / OUT ELFORoom UP
SizesLength (A)Depth (B)Height (C) (A1) (A2) (B1) (B1) (C1)Op. weight
SizesLength (A)Depth (B)Height (C) (A1) (A2) (B1) (B1) (C1)Op. weight
mmmmmmmmmmmmmmmmKg
mmmmmmmmmmmmmmmmKg
55001805001002001751751009
1182518050010020017517510013
15115018050010020017517510016
5630700242300300200200209
119507002423003002002002013
The above data refers to a standard unit.
Technical data Sizes
Sizes
5
5
11
11
15ELFORoom IN / OUTHc / PiCc / Sp / PiAir owFan typeSound pressure levelPPower supply
ELFORoom UPHc / PiCc / Sp / PiAir owFan typeSound pressure levelPPower supply
(1)(2)
(3)
(1)(2)
(3)
kWkWl/s-
dB(A)V/Ph/Hz
1,41 / 0,0181,47 / 1,03 / 0,018
70
35
2,72 / 0,0182,81 / 1,97 / 0,018
139Cross ow36
230/1/50
3,35 / 0,0183,49 / 2,45 / 0,018
189
38
kWkWl/s-
dB(A)V/Ph/Hz
1,45 / 0,0181,46 / 1,04 / 0,018
70
29
2,70 / 0,0182,83 / 1,07 / 0,018
138
37Cross ow
230/1/50
Data referred to the following conditions:(1) Heating capacity / Power input Ambient air at 20°C; inlet water at 45°C and outlet at 40°C.(2) Cooling capacity / Sensible power / Power input. Ambient air at 27°C; 50% R.H.; inlet water 7°C and outlet water 12°C.(3) The sound levels refer to units at full loads, in the rated testing conditions. The sound pressure level refers to a distance of 1 m from the outer surface of the unit operating in an open eld, measured at an air ow of 70%.
ELFORoom INVertical recessed installation
ELFORoom OUTIn-view vertical installation
ELFORoom UPHorizontal recessed installation
Refrig. WATER
ELFOControl
Water roomterminal ELFORoomOUT/IN/UP
34
DisplayControl capacityConnectivityNetwork characteristicsCapacityProtection classPPower supply
TR24X: Power supply transformer 230/1/50 - 24 Vac
CIECX: Recessed pre-installation box
CBSX: shielded cable for RS485 bus
70 x 85 x 65 mm4 moduli DIN
216 x 168 x 73 mm
Matassa da 50 metri
600 x 920 x 150 mm
210 x 155 x 80 mm
157 x 90 x 60 mm 9 moduli DIN
105 x 90 x 60 mm6 moduli DIN
70 x 85 x 61 mm4 moduli DIN
290 x 410 x 140 mm
D.600 x 1680 mm
D.760 x 1690 mm
184 X 82 X 27 mm
184 X 82 X 27 mm
65 x 45 x 54 mm
MIOX: input/output module
CACSX: domestic hot water kit control
KBQRE3X: 300-litre domestic hot water kit
KBQRE3X: 500-litre domestic hot water kit
HID-T2X: local electronic ambient control HID-T2
HID-T3X: local electronic ambient control HID-T3
HID-TI2X: local electronic ambient control HID-Ti2
Functionality
Installation
Radiant panels – Room terminals
System components
Domestic hot water
Thermostats
Dimensions
Permits the transformation from 230/1/50 to 24 VAC to power ELFOControl
Permits recessed installation of ELFOControl
Permits connection of all the devices comprising the system
Replacement generator management (boiler)
Zone valve or relaunch pump management
Remote consent management
Temperature only thermostat – wall installation
Temperature and humidity thermostat – wall installation
Temperature only thermostat – recessed installation
The electronic module used to manage a storage tank not supplied by Clivet
The kit complete with electronic module, 300-litre storage tank, three-way valve
The kit complete with electronic module, 500-litre storage tank, three-way valve
Mixing assembly complete with regulation and plumbing section for low temperature management of radiant panels and high temperature management of room terminals
The electronic module used to manage a mixing assembly not supplied by Clivet
Manages up to 6 shut-off valves which supply radiant panels, radiators or heated towel rails
MManages 1 shut-off valve which supplies radiant panels, radiators or heated towel rails
MPR1X: radiant panel management kit with mixing assembly
KGPRX: control module for mixing assembly
CMZRX: radiant zone module
CMRSX: single zone module
Touchscreen – dimensions 5.7” – colour or black and white10 climate zones – 32 fully manageable elements
1 RS485 serial port (master)Cable for RS485 serial lines (i.e. BELDEN 3105A or similar)
25 VAIP40
2424 VAC 50 Hz—24 VDC
Control unit for residential systems ELFOControl HOME
Dimensions
Technical data
Elements for complete system management
223
176
65
77,65
35
ELFOENERGY HORUS
ELFOENERGY EXTENDED
ELFOENERGY COMPACT
ELFOENERGY MEDIUM
ELFOENERGY HORUS +
ELFOENERGY VULCAN
ELFOENERGY GROUND
ELFOFRESH LARGE
ELFOSPACEOUT-V OUT-H IN-V IN-H
ELFOSPACE BOX2
ELFO
Energy HEATING/COOLING
AIR QUALITYELFOFresh
HEATING/COOLINGDISTRIBUTIONELFODistribution
Air to water heat pump
Radiant panels or room terminals
Low temperature
High temperature radiators
Water to water
heat pump
THE FULL ELFOSystem RANGEIn addition to ELFOSystem GAIA Edition, Clivet is able to supply a full range of heat pumps, air renewal units and room terminals to suit all system or installation application types. The technical data is provided below:
Heat pump suitable for systems with radiant panels and water terminal units, with a design that guarantees quiet operation.
Heat pump optimised for heating for systems with radiant panels and systems with terminal units.
Heat pump, optimised for cooling, suitable for systems with radiant panels and water terminal units.
Air cooled heat pump for outdoor installation.
Heat pump, optimised for heating, suitable for traditional systems with radiators, and guaranteeing maximum efficiency.
High temperature heat pump, for heating only, suitable for traditional systems with radiators.
ELFOENERGY VULCANMEDIUM
High temperature heat pump: able to produce hot water at 60°C even when the outdoor temperature falls to -10°C. The ideal one-stop heating, cooling and hot water solution for centralised systems in residential complexes, hotels and community buildings.
The geothermal heat pump that can be used to heat and cool any kind of building, from new homes to renovation projects, using the free energy found in the ground or water and offering huge benets in terms of energy saving.
Air renewal and purication unit with active thermodynamic recovery for indoor installation.
Water terminal unit for indoor horizontal or vertical, visible or recessed installation.
“Cassette”-type water terminal unit for indoor installation
36
SERVICESClivet has been operating on the Italian market for 20 years, offering solutions for a range of different installation types and for certied high efficiency heat pumps.Our sales network covers the whole of Italy, providing our clients with commercial, technical and training support. Clivet’s widespread distribution network offers its clients a highly professional service, providing them with highly detailed training in the products and systems. Consult the website www.clivet.com for information on local agents.
AFTER-SALES SERVICECCorrect commissioning is essential for an efficient system and satised end customer. Our local partners country by country, together with product and system offer, are available to offer many services in accordance with their standards and local legislation.
ELFOSystem TRAININGTThe Clivet philosophy is customer-focused, and is therefore also focused on training installers in order to make them autonomous when it comes to installing the Elfosystem Home system up to the start-up phase. We dedicate part of our time to training installers and planners, organising specic courses comprised of a theory section, in which we present the systems, products and market opportunities, and a practical section, involving practice with the units themselves. The Clivet training course is divided into two levels:• Course T1 + T2: basic course for presenting the fundamental principles of the Clivet s system, its components and some system design examples• Course P3: Advanced course, providing greater details about the system components, installation methods, start-up and maintenance, with a practical examination on a working system.
OUR WEBSITEwww.clivet.comWWe see the World Wide Web as the ideal means for communicating with our many stakeholders around the world. Our site provides exhaustive information on our products and their applications.
37
Clivet S.p.A. · Via Camp Lonc 25 Z.I. Villapaiera · 32032 · Feltre (BL) ItalyTel. + 39 0439 3131 · Fax + 39 0439 313300 · [email protected]
DF08L001GB-02
www.clivet.com