Electronic thermometer X6 INSTRUCTIONS€¦ · 34.7ºC~37.3ºC 35.8ºC~38ºC 35.8ºC~38ºC Normal...

2
2. Material temperature / body temperature test Click the temperature measurement key, the machine will automatically turn on the power and start the test automatically, and the temperature of the measured object will be displayed on the screen. When the temperature is lower than 37.4 and higher than 32.0 , the screen will use green backlight to light the LCD, and at the same time "drop" sound will remind. 1) Short press the temperature key to test the temperature 2) Click the temperature measurement key once, and then press the key again to switch the O C / O F, and then turn on the machine again to memorize the temperature mode 3.High / low temperature alarm 4. Memory reading In the power on mode, press the temperature measurement key twice, query and remember to flip down, press the temperature measurement key three times, query and remember to flip up, and you can view 32 groups of measurement data at most. 5. Temperature measurement mode switching In the power on state, click and long press for 2 seconds to switch between body mode and object mode. The default body mode is when the power is turned on. 6. Restore factory settings In power on mode, press and hold test key for 10s. VII Precautions for use: Infrared thermometer is a precision electronic product, please use it carefully 1. The infrared temperature gun must be used under the working conditions required by this manual. 2. Do not remove the thermometer from the measurement area before the "drip" sound ends 3. Always place the thermometer in the same position, because different positions may cause deviations in body temperature. 4. According to the difference of human skin color and thickness, the measured temperature will be different. 5. When measuring the temperature of the forehead, make sure that the forehead is clean, and there must be no sweat, hair or hat blocking, otherwise the measured temperature will be low. 6. Do not drop the ground or twist the body 7. It is not necessary to be close to or stacked with other equipment. If it must be close to or stacked, it can only be stacked up to two layers at best. 8. The temperature sensor can be wiped and disinfected with an alcohol cloth in front of the display. Never put it in water or boil it in hot water for disinfection. Note: For the following situations, it is recommended to measure three times, and take the highest reading as the final result. 1. For children under the age of three with impaired immune system and people who have a huge impact on fever. 2. When the user first learns how to use it for measurement, the measurement is repeated many times until he and she are familiar with the device and can read stable data. 3. If the measurement result is abnormally low. In short, the temperature readings measured at different measurement points should not be compared, because the measured values will vary depending on the measurement time. During a day, the person's body temperature is highest in the evening and lowest in the morning before waking up in the morning. Display Thermo Battery Probe I Product Overview Product name: Non medical thermometer Product model: X6 Scope of use: display the body temperature of the measured object by receiving the thermal radiation of the forehead Contraindications: None II Product performance Temperature measurement range: Body temperature mode: 32°C ~ 42.9°C (89.6°F ~ 109.2°F) Temperature mode: 0-50°C (32 °F ~ 122 °F) Temperature measurement time: about 1 seconds Resolution: 0.1°C Maximum allowable error (body temperature mode): Within the range of 35.0 °C ~ 42.0 °C, ± 0.2 °C / ± 32.36 °F; Outside the range of 35.0 °C ~ 42.0 °C, ± 0.3 °C / ± 32.54 °F Maximum allowable error (material temperature mode): Within the range of 0 °C ~ 50.0 °C, ± 2 °C / ± 35.6 °F; Display method: LCD display Appearance size: 13.8x8.3x4.4cm ( height x length x width ) Weight: body about 130g (Battery free) Infrared thermometer with automatic shutdown and self-check function Current consumption: static OFF≤20uA, dynamic ON≤20mA DC power supply: two AAA batteries (No batteries, please buy your own AAA batteries) III Working conditions 1. Ambient temperature: 10 °C ~ 40 °C 2. Relative humidity: 15% ~ 85% 3. Atmospheric pressure: 70kpa ~ 106kpa 4. Internal DC power dc 2.7v-3v IV Technical characteristics 1. The measurement time is about two seconds 2.10 seconds automatic shutdown 3. Switch between °F/ °C with flashing function 4. With backlight, the backlight is blue and orange. 5. Memory reading function 6. Measuring range of infrared thermometer:32 °C -42.9 °C / 90 °F -109 °F 7. Service life: more than 100,000 times normal use 8. This product is tested and verified at a standard 25 °C ambient temperature and 3 cm away from the standard 37 °C thermal radiation source (constant temperature water tank). V Use and operation 1. this product provides two main modes of body temperature measurement and physical measurement 2. Before taking the temperature, please make sure to select the temperature measurement mode Step 1: under the shutdown state, press the measurement key once to turn on the machine and light up the display screen to enter the state to be tested Step 2: place the measuring probe close to the forehead. Make sure that the probe plane is parallel to the forehead plane, and the forehead temperature is measured 1 ~ 3cm away from the forehead. Press the temperature measurement key and hear a drop. The LCD displays the current test value. (when the screen is on, press the measurement key once to measure. If the measurement result is normal, please refer to the data in the following table.) Detection site Age 0 ~ 2 years old 3 ~ 10 years old 11 ~ 65 years old ≥65 years old Normal temperature Normal temperature Anus 36.4ºC~38ºC 35.7ºC~37.5ºC 34.7ºC~37.3ºC 35.8ºC~38ºC 35.8ºC~38ºC Normal temperature Normal temperature 36.4ºC~38ºC 36.1ºC~37.8ºC 35.9ºC~37.6ºC 35.8ºC~37.5ºC 97.5ºF-100.4ºF 97.0ºF-100.0ºF 96.6ºF-99.7ºF 96.4ºF-99.5ºF 97.5ºF-100.4ºF 92.3ºF-99.5ºF 94.7ºF-99.1ºF 96.4ºF-100.4ºF 96.4ºF-100.4ºF Oral cavity Armpit Ear Forehead Reference values of body temperature at different ages Temperature reference value of different measuring parts The maximum allowable error of human clinical diagnostic test accuracy is regulated by the following formula: T1 and T2 are the temperature readings of the tested thermometer twice, and Tref is the fixed reference temperature. TERROR= ≤ 0.3°C / 0.6°C (FOR 95%) T1-TREF T2-TREF 2 + VI Structural function 1.The main structure Infrared thermometer consists of abs plastic shell, temperature probe, buttons, LCD display and battery. VIII Error message and solution IX Battery installation and replacement Please follow the steps below to install the batteries: Step 1: Push the battery cover down in the direction indicated by the arrow. Step 2: Remove the battery cover. Step 3: Put the battery into the battery slot, and pay attention to the positive and negative polarity indications of the battery. Step 4: Close the battery cover. Battery replacement: When the LCD display is dark, it means that the battery is in a low battery state, and the battery must be replaced as soon as possible to ensure measurement accuracy. X Important safety instructions 1. This infrared body temperature gun performs temperature test by detecting the infrared energy radiated from the person's forehead or other targets. He collects the energy through the lens and converts it to a temperature value. By detecting the temperature reading obtained from the area above the eyebrow, the maximum accuracy value . 2. Only applicable for the purposes described in the instructions. If the damage is caused by incorrect use, the manufacturer does not assume legal responsibility. 3. Never immerse this device in water or other liquids. 4. If it is found that the product is obviously abnormal, it is recommended to seek medical treatment in a timely manner and send the product for repair. Except for replacing the battery, please do not open this device without authorization. 5. The operation mode is: continuous operation. Anti-shock type classification: internal power supply equipment. Classification of degree of protection against electric shock: type b application part. 6. Keep away from the following conditions: extreme temperatures, shocks and drops, pollution and dust, and direct sunlight Warning: The use of this device is not a substitute for medical treatment. This device is not waterproof and do not immerse it in liquids. 7. In the early stage of fever, blood vessel contraction occurs and the temperature of the skin surface drops. The temperature measured at this time will be abnormally low. 8. If the measurement result does not match the patient's diagnosis or the measurement temperature is abnormally low, repeat the measurement every 15 minutes or measure another core body temperature zone to verify the previous measurement result. 9. This equipment includes sensitive components and must be treated with caution. For storage and operating conditions, please refer to the section "Symbols and meanings of safety requirements in this machine". 10. Contains small parts, in order to avoid swallowing, children need to use under adult supervision. 11. Please take out the battery when you are not using the device for a period of time, please do not throw away the discarded batteries, pay attention to environmental protection. 12. Ingress protection degree: ipx o. Non-ap / apg, equipment that cannot be used in the presence of flammable anesthetic gas mixed with air or flammable anesthetic gas mixed with oxygen or nitrous oxide. F M C SETTINGS TEMPERATURE DISPLAY AREA VOICE BROADCAST MANUAL OPERATION MEASUREMENT MODE X6 Electronic thermometer INSTRUCTIONS Ambient temperature Object temperature Object temperature Object temperature Object temperature Object temperature < 1 < 10 < 32.0 32.0 - 37.3 37.4 - 38.0 38.1 - 42.8 > 42.8 red red green orange red red err drop Lo drop temperature value temperature value temperature value high DI’’ DI’’ DI’’ DI’’ DI’’ DI‘’ DI’‘ DI’‘ DI’’ DI’’ DI’‘ DI’’ Object mode human mode backlight display sound

Transcript of Electronic thermometer X6 INSTRUCTIONS€¦ · 34.7ºC~37.3ºC 35.8ºC~38ºC 35.8ºC~38ºC Normal...

Page 1: Electronic thermometer X6 INSTRUCTIONS€¦ · 34.7ºC~37.3ºC 35.8ºC~38ºC 35.8ºC~38ºC Normal temperature Normal temperature 36.4ºC~38ºC 36.1ºC~37.8ºC 35.9ºC~37.6ºC 35.8ºC~37.5ºC

2. Material temperature / body temperature testClick the temperature measurement key, the machine will automatically turn on the power and start the test automatically, and the temperature of the measured object will be displayed on the screen. When the temperature is lower than 37.4 ℃ and higher than 32.0 ℃, the screen will use green backlight to light the LCD, and at the same time "drop" sound will remind.1) Short press the temperature key to test the temperature2) Click the temperature measurement key once, and then press the key again to switch the OC / OF, and then turn on the machine again to memorize the temperature mode

3.High / low temperature alarm

4. Memory readingIn the power on mode, press the temperature measurement key twice, query and remember to �ip down, press the temperature measurement key three times, query and remember to �ip up, and you can view 32 groups of measurement data at most.

5. Temperature measurement mode switchingIn the power on state, click and long press for 2 seconds to switch between body mode and object mode. The default body mode is when the power is turned on.

6. Restore factory settingsIn power on mode, press and hold test key for 10s.

VII Precautions for use:Infrared thermometer is a precision electronic product, please use it carefully1. The infrared temperature gun must be used under the working conditions required by this manual.2. Do not remove the thermometer from the measurement area before the "drip" sound ends3. Always place the thermometer in the same position, because di�erent positions may cause deviations in body temperature.4. According to the di�erence of human skin color and thickness, the measured temperature will be di�erent.5. When measuring the temperature of the forehead, make sure that the forehead is clean, and there must be no sweat, hair or hat blocking, otherwise the measured temperature will be low.6. Do not drop the ground or twist the body7. It is not necessary to be close to or stacked with other equipment. If it must be close to or stacked, it can only be stacked up to two layers at best.8. The temperature sensor can be wiped and disinfected with an alcohol cloth in front of the display. Never put it in water or boil it in hot water for disinfection.

Note: For the following situations, it is recommended to measure three times, and take the highest reading as the �nal result.1. For children under the age of three with impaired immune system and people who have a huge impact on fever.2. When the user �rst learns how to use it for measurement, the measurement is repeated many times until he and she are familiar with the device and can read stable data.3. If the measurement result is abnormally low.In short, the temperature readings measured at di�erent measurement points should not be compared, because the measured values will vary depending on the measurement time. During a day, the person's body temperature is highest in the evening and lowest in the morning before waking up in the morning.

Display

Thermo

Battery

Probe

I Product OverviewProduct name: Non medical thermometerProduct model: X6Scope of use: display the body temperature of the measured object by receiving the thermal radiation of the foreheadContraindications: None

II Product performanceTemperature measurement range:Body temperature mode: 32°C ~ 42.9°C (89.6°F ~ 109.2°F)Temperature mode: 0-50°C (32 °F ~ 122 °F)Temperature measurement time: about 1 secondsResolution: 0.1°C

Maximum allowable error (body temperature mode):Within the range of 35.0 °C ~ 42.0 °C, ± 0.2 °C / ± 32.36 °F;Outside the range of 35.0 °C ~ 42.0 °C, ± 0.3 °C / ± 32.54 °F

Maximum allowable error (material temperature mode):Within the range of 0 °C ~ 50.0 °C, ± 2 °C / ± 35.6 °F;Display method: LCD displayAppearance size: 13.8x8.3x4.4cm ( height x length x width )Weight: body about 130g (Battery free)Infrared thermometer with automatic shutdown and self-check functionCurrent consumption: static OFF≤20uA, dynamic ON≤20mADC power supply: two AAA batteries (No batteries, please buy your own AAA batteries)

III Working conditions1. Ambient temperature: 10 °C ~ 40 °C2. Relative humidity: 15% ~ 85%3. Atmospheric pressure: 70kpa ~ 106kpa4. Internal DC power dc 2.7v-3v

IV Technical characteristics1. The measurement time is about two seconds2.10 seconds automatic shutdown3. Switch between °F/ °C with �ashing function4. With backlight, the backlight is blue and orange.5. Memory reading function6. Measuring range of infrared thermometer:32 °C -42.9 °C / 90 °F -109 °F7. Service life: more than 100,000 times normal use8. This product is tested and veri�ed at a standard 25 °C ambient temperature and 3 cm away from the standard 37 °C thermal radiation source (constant temperature water tank).

V Use and operation1. this product provides two main modes of body temperature measurement and physical measurement2. Before taking the temperature, please make sure to select the temperature measurement modeStep 1: under the shutdown state, press the measurement key once to turn on the machine and light up the display screen to enter the state to be testedStep 2: place the measuring probe close to the forehead. Make sure that the probe plane is parallel to the forehead plane, and the forehead temperature is measured 1 ~ 3cm away from the forehead. Press the temperature measurement key and hear a drop. The LCD displays the current test value.

(when the screen is on, press the measurement key once to measure. If the measurement result is normal, please refer to the data in the following table.)

Detection site Age

0 ~ 2 years old

3 ~ 10 years old

11 ~ 65 years old

≥65 years old

Normal temperature Normal temperature

Anus 36.4ºC~38ºC

35.7ºC~37.5ºC

34.7ºC~37.3ºC

35.8ºC~38ºC

35.8ºC~38ºC

Normal temperature Normal temperature

36.4ºC~38ºC

36.1ºC~37.8ºC

35.9ºC~37.6ºC

35.8ºC~37.5ºC

97.5ºF-100.4ºF

97.0ºF-100.0ºF

96.6ºF-99.7ºF

96.4ºF-99.5ºF

97.5ºF-100.4ºF

92.3ºF-99.5ºF

94.7ºF-99.1ºF

96.4ºF-100.4ºF

96.4ºF-100.4ºF

Oral cavity

Armpit

Ear

Forehead

Reference values of body temperature at di�erent ages

Temperature reference value of di�erent measuring parts

The maximum allowable error of human clinical diagnostic test accuracy is regulated by the following formula:

T1 and T2 are the temperature readings of the tested thermometer twice, and Tref is the �xed reference temperature.

TERROR=

≤ 0.3°C / 0.6°C (FOR 95%)

T1-TREF T2-TREF2+

VI Structural function1.The main structure

Infrared thermometer consists of abs plastic shell, temperature probe, buttons, LCD display and battery.

VIII Error message and solution

IX Battery installation and replacementPlease follow the steps below to install the batteries:Step 1: Push the battery cover down in the direction indicated by the arrow.Step 2: Remove the battery cover.Step 3: Put the battery into the battery slot, and pay attention to the positive and negative polarity indications of the battery.Step 4: Close the battery cover.

Battery replacement:When the LCD display is dark, it means that the battery is in a low battery state, and the battery must be replaced as soon as possible to ensure measurement accuracy.

X Important safety instructions1. This infrared body temperature gun performs temperature test by detecting the infrared energy radiated from the person's forehead or other targets. He collects the energy through the lens and converts it to a temperature value. By detecting the temperature reading obtained from the area above the eyebrow, the maximum accuracy value .2. Only applicable for the purposes described in the instructions. If the damage is caused by incorrect use, the manufacturer does not assume legal responsibility.3. Never immerse this device in water or other liquids.4. If it is found that the product is obviously abnormal, it is recommended to seek medical treatment in a timely manner and send the product for repair. Except for replacing the battery, please do not open this device without authorization.5. The operation mode is: continuous operation. Anti-shock type classi�cation: internal power supply equipment.Classi�cation of degree of protection against electric shock: type b application part.6. Keep away from the following conditions: extreme temperatures, shocks and drops, pollution and dust, and direct sunlightWarning: The use of this device is not a substitute for medical treatment. This device is not waterproof and do not immerse it in liquids.7. In the early stage of fever, blood vessel contraction occurs and the temperature of the skin surface drops. The temperature measured at this time will be abnormally low.8. If the measurement result does not match the patient's diagnosis or the measurement temperature is abnormally low, repeat the measurement every 15 minutes or measure another core body temperature zone to verify the previous measurement result.9. This equipment includes sensitive components and must be treated with caution. For storage and operating conditions, please refer to the section "Symbols and meanings of safety requirements in this machine".10. Contains small parts, in order to avoid swallowing, children need to use under adult supervision.11. Please take out the battery when you are not using the device for a period of time, please do not throw away the discarded batteries, pay attention to environmental protection.12. Ingress protection degree: ipx o. Non-ap / apg, equipment that cannot be used in the presence of �ammable anesthetic gas mixed with air or �ammable anesthetic gas mixed with oxygen or nitrous oxide.

F

M

CSETTINGS

TEMPERATURE DISPLAY AREA

VOICE BROADCAST MANUAL OPERATION

MEASUREMENT MODE

X6Electronic thermometerINSTRUCTIONS

Ambient temperatureObject temperatureObject temperatureObject temperatureObject temperatureObject temperature

< 1 ℃ < 10 ℃< 32.0 ℃

32.0 ℃ - 37.3 ℃37.4 ℃ - 38.0 ℃38.1 ℃ - 42.8 ℃

> 42.8 ℃

redred

greenorange

redred

err dropLo drop

temperature valuetemperature valuetemperature value

high

DI’’ DI’’ DI’’DI’’ DI’’ DI‘’

DI’‘DI’‘DI’’

DI’’ DI’‘ DI’’

Object mode human mode backlight display sound

Page 2: Electronic thermometer X6 INSTRUCTIONS€¦ · 34.7ºC~37.3ºC 35.8ºC~38ºC 35.8ºC~38ºC Normal temperature Normal temperature 36.4ºC~38ºC 36.1ºC~37.8ºC 35.9ºC~37.6ºC 35.8ºC~37.5ºC

2. Material temperature / body temperature testClick the temperature measurement key, the machine will automatically turn on the power and start the test automatically, and the temperature of the measured object will be displayed on the screen. When the temperature is lower than 37.4 ℃ and higher than 32.0 ℃, the screen will use green backlight to light the LCD, and at the same time "drop" sound will remind.1) Short press the temperature key to test the temperature2) Click the temperature measurement key once, and then press the key again to switch the OC / OF, and then turn on the machine again to memorize the temperature mode

3.High / low temperature alarm

4. Memory readingIn the power on mode, press the temperature measurement key twice, query and remember to �ip down, press the temperature measurement key three times, query and remember to �ip up, and you can view 32 groups of measurement data at most.

5. Temperature measurement mode switchingIn the power on state, click and long press for 2 seconds to switch between body mode and object mode. The default body mode is when the power is turned on.

6. Restore factory settingsIn power on mode, press and hold test key for 10s.

VII Precautions for use:Infrared thermometer is a precision electronic product, please use it carefully1. The infrared temperature gun must be used under the working conditions required by this manual.2. Do not remove the thermometer from the measurement area before the "drip" sound ends3. Always place the thermometer in the same position, because di�erent positions may cause deviations in body temperature.4. According to the di�erence of human skin color and thickness, the measured temperature will be di�erent.5. When measuring the temperature of the forehead, make sure that the forehead is clean, and there must be no sweat, hair or hat blocking, otherwise the measured temperature will be low.6. Do not drop the ground or twist the body7. It is not necessary to be close to or stacked with other equipment. If it must be close to or stacked, it can only be stacked up to two layers at best.8. The temperature sensor can be wiped and disinfected with an alcohol cloth in front of the display. Never put it in water or boil it in hot water for disinfection.

Note: For the following situations, it is recommended to measure three times, and take the highest reading as the �nal result.1. For children under the age of three with impaired immune system and people who have a huge impact on fever.2. When the user �rst learns how to use it for measurement, the measurement is repeated many times until he and she are familiar with the device and can read stable data.3. If the measurement result is abnormally low.In short, the temperature readings measured at di�erent measurement points should not be compared, because the measured values will vary depending on the measurement time. During a day, the person's body temperature is highest in the evening and lowest in the morning before waking up in the morning.

XI Maintenance method1. Always keep the surface of the thermometer clean and tidy, which helps to extend the life of the thermometer.2. If the machine is dirty, wipe it with a clean soft cotton cloth. If the dirt is not easy to remove, you can wipe the soft cotton cloth with water or a neutral detergent, and then dry it with a dry cloth.Note: Do not allow water or other liquids to enter the body.

XII Precautions for storage1. The temperature gun contains sensitive electronic components, and it should be avoided to use directly in the environment with electromagnet-ic wave interference (for example: near mobile phones, microwave ovens, etc.), in order to prevent temporarily a�ecting its accuracy.2. Please don't use volatile oil, thinner or gasoline to wipe the thermome-ter with liquid thermometer.3. Do not store the product in direct sunlight, high temperature and humidity; dusty, corrosive gas.4. When the temperature gun is not used for a long time (more than 3 months), please remove the battery from the body.5. Please do not use the thermometer for purposes other than its original design. When used on children, please observe the general safety precautions.6. If there are signs of damage to the probe or the thermometer itself, please do not continue to use it.7. Please do not drop the temperature gun to the ground to avoid strong shock and shock.8. In order to avoid short circuit, please do not put the battery together with metal objects such as coins or keychains in the same pocket or other containers that may be short circuited by the battery.9. Do not put the battery close to the �re or put it into the �re to avoid battery explosion. Do not use the battery when it leaks or molds. Discard the battery or this product in accordance with local regulations.10. When performing warranty service, if you need to provide circuit diagrams, necessary materials, and troubleshooting of electrical circuits, please contact the manufacturer.

Note: If you fail to observe the above storage precautions and other correct use methods caused by machine failure, our company will not be responsible for quality.

XIII Thirteen other considerationsPeriod of useUnder the conditions that meet the storage regulations, the product life span is 3 years (except for vulnerable and consumable parts),The temperature gun calibration must be returned to the manufacturer.See certi�cate of production date.Product transportation and storageProduct transportation and storage environment:Temperature: -20°C ~ + 50°C Relative humidity: 85% in winterAtmospheric pressure: 70kpa ~ 106kpa

XIV Clinical measurement accuracy and safety veri�cationThrough clinical comparison of this product, the clinical accuracy and safety of the infrared body temperature gun meet the clinical use requirements and can meet the clinical application needs.

XV List of attachmentsHost: 1;Instructions: 1;Quali�cation certi�cate: 1;Alkaline batteries, two No. 5 batteries (aa batteries): 2 cells.During the warranty service, if you need to provide circuit diagrams, necessary materials, and electrical circuit troubleshooting, please contact the manufacturer.

XVI Guidance on the use of electromagnetic environment Excerpts from the manufacturer's random documents related to emc guidelines and statements

VI Structural function1.The main structure

Infrared thermometer consists of abs plastic shell, temperature probe, buttons, LCD display and battery.