Electrochemistry - Fuel cells - Energy - Environmental ... · PDF fileElectrochemical...

36
- when you need to be sure... Electrochemistry - Fuel cells - Energy - Environmental Analysis - Corrosion - Education

Transcript of Electrochemistry - Fuel cells - Energy - Environmental ... · PDF fileElectrochemical...

Page 1: Electrochemistry - Fuel cells - Energy - Environmental ... · PDF fileElectrochemical Laboratories 3 Specifications 7 Connections 8 Software 9 Corrosion 16 Voltammetry 17 Impedance

- when you need to be sure...

Electrochemistry - Fuel cells - Energy - Environmental Analysis - Corrosion - Education

Page 2: Electrochemistry - Fuel cells - Energy - Environmental ... · PDF fileElectrochemical Laboratories 3 Specifications 7 Connections 8 Software 9 Corrosion 16 Voltammetry 17 Impedance

Electrochemical Laboratories 3Specifications 7

Connections 8

Software 9Corrosion 16

Voltammetry 17

Impedance 18

Polarography 19

Universal Differential Pulse 20

Battery testing 21

Post-run processing 24

Additional units 25Current Voltage Boosters 26

Rotating Disc Electrode Stand 27

Polarographic Stand 28

Trace analysis 29

Rotating Disc Electrodes 31

Electrodes 33

Cells 34

VoltaLab®

Get a free poster for your lab

www.voltalab.com

VoltaLab instrumentation is ideal for dc and acelectrochemical analysis applications in corrosion,pitting tests, battery testing, fuel cells, electroplat-ing, electrocatalysis, nano materials, coatings andsensor development and includes a series ofpotentiostats and current/voltage boosters.

Page 3: Electrochemistry - Fuel cells - Energy - Environmental ... · PDF fileElectrochemical Laboratories 3 Specifications 7 Connections 8 Software 9 Corrosion 16 Voltammetry 17 Impedance

Simplicity

InnovationVoltaLab offers outstanding software and high-performance hardware with innovative featuressuch as the “Time evolution” concept. This exclusivefunction represents a veritable revolution in theworld of electrochemistry.

All-in-one conceptThe VoltaLab “All-in-one” concept is very simple tounderstand and even simpler to benefit from. Onesoftware and one “potentiostat” are all you need!You can run any type of electrochemical experi-ment. There is no need to install a specific card inyour PC. Communication is compatible withUSB/RS232C connectors.

Full/RoutineVoltaMaster 4 can be run in full or routine mode.In routine mode, access to programing is restricted,providing additional security.

Customer [email protected] asked VoltaLab users to tell us what wouldreally help them save time. Then we added it toVoltaMaster 4 to offer the most complete electro-chemical software on the market.

Exclusive functionsThe tools methods is what makes VoltaLab standout from rival products. It allows you to drive yourexperiment by creating protocols which respondaccording to automatically calculated results suchas the intensity of a peak or its position.

Maximum efficiencyConcentrate on your research. Forget about tech-nical difficulties. VoltaLab offers the easiest to useand most versatile “All-in-one” potentiostats on themarket. See how you can master your electro-chemical interfaces with VoltaLab.

Register at www.voltalab.comWhen you register to download VoltaMaster 4software, you will discover that the VoltaLab all-in-one concept is the best solution for your experi-mental needs, whatever they may be.

2

Page 4: Electrochemistry - Fuel cells - Energy - Environmental ... · PDF fileElectrochemical Laboratories 3 Specifications 7 Connections 8 Software 9 Corrosion 16 Voltammetry 17 Impedance

Every VoltaLab electrochemical laboratory consistsof a potentiostat, VoltaMaster 4 software and a setof cables.

3

Electrochemical LaboratoriesControlled by VoltaMaster 4

Auto Peak Analysis

“Time evolution”

Scan rate 0.01 V/s 0.5 V/s 20 V/s 20 V/s 20 V/s

Best current resolution 100 pA 30 pA 30 pA 0.3 pA 0.3 pA

EIS Maximum frequency 100 kHz 100 kHz/40 kHz 100 kHz/40 kHz

EIS Modes Potentiostatic Potentiostatic PotentiostaticGalvanostatic Galvanostatic

Recommended for Corrosion Education Development Quantitative Fundamentalanalysis research

VoltaLab 21Self-contained system equipped with programmablecontrols on the front panel. Able to function bothin floating and non-floating mode.

VoltaLab 10All-in-one system which brings you a multitude offunctions in a compact box at an unbeatable price.

VoltaLab 40Dynamic system which combines outstanding per-formance and ease of use. A major breakthroughin the field of ohmic drop compensation withdynamic compensation controlled by impedancemeasurement.

VoltaLab 50Analytical system which offers the conveniencerequired for routine use of cyclic voltammetry inquantitative analysis.

VoltaLab 80Universal system which enables you to develop andperform all current electrochemical experiments,even the most complex. Automatic processing andefficient peripheral management functions.

VoltaLab 21 VoltaLab 10 VoltaLab 40 VoltaLab 50 VoltaLab 80

See page 25 for additional units

• • • • •• •

Page 5: Electrochemistry - Fuel cells - Energy - Environmental ... · PDF fileElectrochemical Laboratories 3 Specifications 7 Connections 8 Software 9 Corrosion 16 Voltammetry 17 Impedance

VoltaLab 50 is an analytical quantitative laboratorywhich automates and simplifies any type of elec-trochemical analysis using standard addition,standard calibration and calibration by addition.Everything is made easy and practical. Forinstance the spectrums can be automatically com-pared to reference spectrum in order to establisha “pass or fail“ protocol. User-selectable unitsand blank and dilution factor management aresome of the fundamental features provided. EveryDC technique can be set and run, including theextraordinarily powerful Universal DifferentialPulse method.

VoltaLab 21 is a compact potentiostat/galvanostatwith built-in signal generator that can be used asa stand-alone instrument when it is programmedthrough its front panel. In this manual mode, thepotentiostat scan rate can be selected up to 2.5 V/s. With VoltaMaster 4, the maximum scanrate is 10 mV/s. Ideal for corrosion studies,VoltaLab 21 records the polarisation resistanceand the corrosion potential over very long peri-ods. Pitting tests as well as coupled corrosion testsare available. VoltaLab 21 works either in float-ing or non-floating mode.

VoltaLab 21Economical Electrochemical Laboratory

Front panelRolling menu settingsLarge LCD displayM

anua

l

VoltammetryMaximum compliance voltage ±20 VMaximum current output ±1 AMaximum polarisation voltage ±4 V

Ordering informationVoltaLab 21 (230 V) A41A009VoltaLab 21 (115 V) A41A010

VoltaLab 50Analytical Electrochemical Laboratory

VoltammetryUniversal DP

Ana

lytic

al

Ordering informationVoltaLab 50 (230 V) R21V015VoltaLab 50 (115 V) R21V016

VoltammetryMaximum compliance voltage ±30 VMaximum current output ±1 AMaximum polarisation voltage ±15 V

PGP201 Economical Potentiostat

PST050Analytical Potentiostat

4

See page 7 and 8 for more technical data

Page 6: Electrochemistry - Fuel cells - Energy - Environmental ... · PDF fileElectrochemical Laboratories 3 Specifications 7 Connections 8 Software 9 Corrosion 16 Voltammetry 17 Impedance

EIS

VoltaLab 40 is a dynamic system which combinesoutstanding performance and ease of use. It rep-resents a major breakthrough in the field of ohmicdrop compensation by offering dynamic compen-sation controlled by impedance measurement. It isthe obvious choice for high-level researchers. As itis the easiest to use and most versatile “all-in-one” potentiostat on the market, it is ideal forElectrochemical Impedance Spectroscopy combinedwith conventional methods such as Voltammetry.

VoltaLab 10 is an all-in-one system which bringsyou a multitude of functions in a compact box atan unbeatable price. As it is the easiest to use“all-in-one” potentiostat on the market, it is theobvious choice for teaching or for beginners inelectrochemistry. It offers Voltammetry and Electro-chemical Impedance Spectroscopy.

Ordering informationVoltaLab 40 (230 V) R21V007VoltaLab 40 (115 V) R21V008

VoltammetryMaximum compliance voltage ±30 VMaximum current output ±1 AMaximum polarisation voltage ±15 V

Electrochemical ImpedanceMax. frequency 100 kHzMin. frequency 1 mHz

VoltammetryMaximum compliance voltage ±30 VMaximum current output ±1 AMaximum polarisation voltage ±15 V

Electrochemical ImpedanceMax. frequency 100 kHzMin. frequency 1 mHz

Ordering informationVoltaLab 10 (230 V) R21V011VoltaLab 10 (115 V) R21V012

5

VoltaLab 10All-in-one Electrochemical Laboratory

SimplicityVoltammetryImpedance

Educ

atio

n

VoltaLab 40Dynamic Electrochemical Laboratory

PotentiostatSignal generatorDigital acquisition

Com

plet

e

PGZ100All-in-one Potentiostat

PGZ301Dynamic Potentiostat

See page 7 and 8 for more technical data

EIS

Page 7: Electrochemistry - Fuel cells - Energy - Environmental ... · PDF fileElectrochemical Laboratories 3 Specifications 7 Connections 8 Software 9 Corrosion 16 Voltammetry 17 Impedance

EIS

You can obtain a 2 separate working electrode system immediately with VoltaLab. Simply combinetwo potentiostats to obtain a bipotentiostat. Twoworking electrodes, one counter electrode and onereference electrode. The ring and disc currentsare saved in the same file.

VoltaLab 80 is a universal instrument that willserve your imagination, making the use of delicateelectrochemistry so simple and efficient that youwill benefit from its potential straightaway.Everything is available from the simplest tutorialto the ultimate state-of-the-art methods, the“Universal Differential Pulse”. These universalmethods exist either in recurrent mode (for batterytesting) or over a potential ramp for analyticalpurposes. VoltaLab 80 is the most versatile poten-tiostat and software combination around.

VoltammetryMaximum compliance voltage ±30 VMaximum current output ±1 AMaximum polarisation voltage ±15 V

Electrochemical ImpedanceMax. frequency 100 kHzMin. frequency 1 mHz

Ordering informationVoltaLab 80 (230 V) R21V009VoltaLab 80 (115 V) R21V010

VoltaLab 80Universal Electrochemical Laboratory

Universal PulseDynamic EISVoltammetry

Uni

vers

al

BipotentiostatCombination of 2 potentiostats (see p. 25)

Two potentiostats* canbe put together to makea bipotentiostat

Easy

PGZ402Universal Potentiostat

6

*Possible combinationsPGZ402 + PGZ402 PGZ301 + PGZ100PGZ402 + PGZ301 PGZ301 + PST050PGZ402 + PGZ100 PGZ301 + PGZ301PGZ402 + PST050 PGZ100 + PST050Recommended: PGZ100 + PST050

Page 8: Electrochemistry - Fuel cells - Energy - Environmental ... · PDF fileElectrochemical Laboratories 3 Specifications 7 Connections 8 Software 9 Corrosion 16 Voltammetry 17 Impedance

7

Hardware

Compliance voltage ±30 V* ±30 V* ±30 V* ±30 V* ±20 V

Maximum current output ±1 A ±1 A** ±1 A ±1 A ±1 APolarisation voltage ±15 V ±15 V ±15 V ±15 V ±4 VSlew rate 10000 KV/s 10000 KV/s 10000 KV/s 10000 KV/s 300 KV/sRise time (100% signal) < 1µs < 1µs < 1µs < 1µs < 4 µsBandwidth (-3dB) 800 kHz 800 kHz 800 kHz 800 kHz 200 kHz Current autoranging Yes Yes Yes Yes YesPotential autoranging Yes Yes Yes Yes YesMeasurements (A/D converters) 16 bits 16 bits 16 bits 16 bits 20000 points

Applied DC potentialRanges ±4, 8, 15 V ±4, 8, 15 V ±4, 8, 15 V ±4, 8, 15 V ±4 VBest resolution 125 µV 125 µV 125 µV 125 µV 125 µVAccuracy (% of range) ±0.2% ±0.2% ±0.2% ±0.2% ±0.2%

Measured potentialRanges ±2, 4, 8, 15 V ±2, 4, 8, 15 V ±2, 4, 8, 15 V ±2, 4, 8, 15 V ±8 VBest resolution 60 µV 60 µV 60 µV 60 µV 1 mVResolution (% of range) 0.003% 0.003% 0.003% 0.003% 0.0125%Accuracy (% of range) ±0.2% ±0.2% ±0.2% ±0.2% ±0.2%Analogue output Yes Yes Yes Yes YesDC offset and gain (10 & 100) Yes Yes Yes for EIS Yes for EIS No

Measured currentHighest range 1 A (9 ranges) 1 A (9 ranges) 1 A (7 ranges) 1 A (7 ranges) 1 A (7 ranges)Lowest range 10 nA (with gain) 10 nA (with gain) 1 µA 1 µA 1 µABest resolution 300 fA (with gain) 300 fA (with gain) 30 pA 30 pA 100 pAResolution (% of range) 0.003% 0.003% 0.003% 0.003% 0.01%

Accuracy (% of range) ±0.2%*** ±0.2%*** ±0.2%*** ±0.2%*** ±0.2%***DC offset and gain (10 & 100) Yes Yes Yes for EIS Yes for EIS NoAnalogue output Yes Yes Yes Yes YesAutomatic filters Yes Yes Yes Yes YesManual filters 7 filters 7 filters 7 filters 7 filters 5 filtersAnti-oscillation filter Yes Yes Yes Yes No

Scanning performancesMeasurement period 0.5 ms 0.5 ms 0.5 ms 20 ms 1 sMax. scan rate (10 mV steps) 20 V/s 20 V/s 20 V/s 500 mV/s 10 mV/s

Ohmic Drop CompensationDynamic Impedance Driven Yes Yes Yes NoStatic manual & Static auto Yes Yes Yes YesFeedback manual & Feedback auto Yes Yes Yes No

Electrochemical ImpedanceMax. frequency 100 kHz 100 kHz 100 kHzMin. frequency 1 mHz 1 mHz 1 mHzFrequencies/decade 5, 10, 20 5, 10, 20 5, 10, 20Sine wave amplitude 1 mV to 1 V 1 mV to 1 V 1 mV to 1 VRanges for AC potential 50 & 1000 mV 50 & 1000 mV 50 & 1000 mVResolution 12.5 & 250 µV 12.5 & 250 µV 12.5 & 250 µVAccuracy (% of range) ±0.5% ±0.5% ±0.5%Current autoranging Yes Yes YesDelay before integration Yes Yes YesEIS distortion for module 1% ±(0.02%/kHz) 1% ±(0.02%/kHz) 1% ±(0.02%/kHz)EIS distortion for phase shift 1°±(0.02°/kHz) 1°±(0.02°/kHz) 1% ±(0.02%/kHz)

Volta

Lab

80

Volta

Lab

40

Volta

Lab

10

Volta

Lab

21

Volta

Lab

50

Electrical specifications

* C

an b

e in

crea

sed

to 1

00 V

with

the

HV

B100

Hig

h Vo

ltage

Boo

ster

** C

an b

e in

crea

sed

to 2

0 A

with

the

HC

B020

Cur

rent

Boo

ster

***

1% w

ith 1

00 n

A a

nd 1

0 nA

ran

ge

Page 9: Electrochemistry - Fuel cells - Energy - Environmental ... · PDF fileElectrochemical Laboratories 3 Specifications 7 Connections 8 Software 9 Corrosion 16 Voltammetry 17 Impedance

Rear panel connectionsFunctional ground to connect a Faraday cage Banana BananaSerial port to connect a Pentium based PC RS232C SUB-D9 male

Cell connectionsREF (Reference Electrode, RE) BNC BNC

Input impedance 10¹² Ohm 10¹² OhmCapacitance <20 pF <20 pF

WORK (Working Electrode, WE) PL259 PL259 Output impedance Low Low

AUX (Auxiliary Electrode, CE) PL259 PL259 Output impedance Low Low

Additional channel connectionsE OUT (Measured potential output) BNC BNC

Range ±15 V ±8 VAccuracy (% of range) ±0.2% ±0.2%

I OUT (Measured current output) BNC BNCRange (Linear with current range) ±1 V ±1 VAccuracy (% of range) ±0.2% ±0.2%

Vg IN (External Generator) BNC BNCRange ±10 V ±5 VInput impedance 10 kOhm 20 kOhm

Additional cell connectionsSENSE (For 4-pole measurements) BNC

Input impedance Low

Additional channelsA/D IN (Input) BNC

Range ±5000 mVResolution 152.5 µVAccuracy (% of range) ± 0.1%Input impedance 10 MOhmInput synchronised with E & i

D/A OUT (Output) BNC Range 0 - 5000 mVResolution 1.2 mVAccuracy (% of range) ±0.05%

Additional Unit connectionsVg OUT (To external potentiostat) BNC

Range ±15 VOutput impedance Low

E (X) IN (Channel X) BNC Range ±15 VInput impedance 10 KOhm

I (Y) IN (Channel Y) BNCRange ±1 VInput impedance 10 KOhm

Volta

Lab

80Vo

ltaLa

b 40

Volta

Lab

10

Volta

Lab

21

Volta

Lab

50

GeneralPower supply 115/230 Vac + 15-18%

47.5-63 HzSize & Weight 485 x 300 x 88 mm & 13 kg

8

SynchronisationThe A/D IN input is synchronised withpotential and current acquisitions. It canbe used to record the temperature or anyother useful data. The D/A OUT output issynchronised with the start of any method.It can be used to set the speed of a rotat-ing electrode or to start or regulate anyother experimental instrument.

Connections

Page 10: Electrochemistry - Fuel cells - Energy - Environmental ... · PDF fileElectrochemical Laboratories 3 Specifications 7 Connections 8 Software 9 Corrosion 16 Voltammetry 17 Impedance

9

Software

VoltaMaster 4This superb software is the cornerstone of yourVoltaLab Electrochemical Laboratory.

Designed by electrochemistsThe only way to satisfy users’ requirements is tolisten to what they have to say. That’s our policy.To tell the truth it is you, the electrochemists, whohave designed the VoltaLab family of instruments.

Simple to useProgramming, archiving and data handling couldnot be easier. Whether you are an absolute begin-ner or an expert, it takes five minutes to feel confi-dent with VoltaLab thanks to intuitive multitaskingsoftware.

Free upgradeVisit www.voltalab.com and register your VoltaLabsystem to benefit from your free VoltaMaster 4 lat-est version right now!

VoltaMaster 4 minimum PCrequirements

• 64 MB of RAM, 50% free space• Microsoft Windows® 95, Windows® 98,

Windows® NT 4.0, Windows 2000 Professionaledition, Windows Millenium or Windows XP

• Microsoft Excel 97 for users working with theVM4RESULTS.XLS calculation results file

• Pentium II 400 MHz microprocessor• CD-ROM drive• RS232C serial interface - PC with USB port only:

use a separate USB to RS232C converter box• Printer connection• VGA colour graphics card (min. screen resolution

600x800 on the "Desktop")• Windows compatible mouse• 2 GB hard disk, 50% free space

Page 11: Electrochemistry - Fuel cells - Energy - Environmental ... · PDF fileElectrochemical Laboratories 3 Specifications 7 Connections 8 Software 9 Corrosion 16 Voltammetry 17 Impedance

34 acquisition methodsto measure experimental data

Visual methodsVisual EISVisual IFV

Electrochemical methodsOpen Circuit PotentialPot. Tutorial Cyclic VoltammetryPot. Tutorial Chrono AmperometryPot. Interactive Cyclic VoltammetryPot. Linear VoltammetryGal. Linear VoltammetryPot. Cyclic VoltammetryGal. Cyclic VoltammetryPot. Step by step Cyclic Voltammetry Gal. Logarithmic Cyclic VoltammetryPot. Low Current Cyclic VoltammetryTast Polarography

Pot. Expert EISPot. Tutorial EIS (Impedance)Pot. Dynamic EIS (Impedance)Pot. Fixed Freq. EIS (Capacitance)Gal. Tutorial EIS (Impedance)

Chrono AmperometryChrono CoulometryChrono PotentiometryGal.Coulometry Low Current Chrono Amperometry

Pot. Universal Differential Pulse VoltammetryGal. Universal Differential Pulse VoltammetryPot. Recurrent Differential Pulse VoltammetryGal. Recurrent Differential Pulse VoltammetryPot. Square Wave VoltammetryGal. Square Wave Voltammetry

Pitting corrosionGeneral corrosion (Rp)Coupled corrosion (Evans)Polarisation for corrosion (Tafel)

Volta

Lab

10Vo

ltaLa

b 40

Volta

Lab

80

Volta

Lab

21 • Voltammetry• Electrochemical Impedance• Analytical pulses• Corrosion• Battery/Energy• Material testing

10

Volta

Lab

50

Page 12: Electrochemistry - Fuel cells - Energy - Environmental ... · PDF fileElectrochemical Laboratories 3 Specifications 7 Connections 8 Software 9 Corrosion 16 Voltammetry 17 Impedance

Run External Utility

Auto. Peak Analysis

Auto. R1R2C Fitting

Auto Linear Extraction

Vg IN On/Off

Auto. Traject

Message

Relocate potentials

If/if not method

Jump to method

Last point

Current efficiency

Print report

Yes or No?

Save curve as

Sort out by potential

Results from Results: Linear combination of results

Time evolution

Standard addition

Standard calibration

Calibration by addition

Calibration CV ST

Sample CV ST

11

Virtual mode

• Automatic Calculation• Automatic Report• External Utility Control• Dialogue boxes• Time Evolution• Data Quality Management• Loops

23 tool methodsto organise protocols and calculate results

Volta

Lab

10Vo

ltaLa

b 40

Volta

Lab

80

Volta

Lab

21

Volta

Lab

50

Page 13: Electrochemistry - Fuel cells - Energy - Environmental ... · PDF fileElectrochemical Laboratories 3 Specifications 7 Connections 8 Software 9 Corrosion 16 Voltammetry 17 Impedance

“Time Evolution”

Exclusive and outstandingTime evolution lets you record the calculatedresults as a function of time. This method takesplace within a loop: measurement, calculation,Time evolution, jump to measurement… as manytimes as you need. Investigating material ageingor new sensor performance has never been soeasy.

12

3-D plotImagine that in addition to your experimentalvoltammetry you will get one calculated resultscurve plus a file containing all the curves used forthe calculations. You can display a representationin 3-D.

Data Quality ManagementThis calculated curve is plotted on the screen dur-ing acquisition. The last value, date and time of itsacquisition and countdown until the next measure-ment are all displayed so you know your exactprogress. You can adjust the scale manually for aclearer overview. The value is expressed in the unit and with thename selected in the calculation method.

Protocol organisationTime evolution not only displays these values; italso compares the last result with a set high andlow value. This means action can be takenstraightaway, for example automatically addingreagent from a burette.

Page 14: Electrochemistry - Fuel cells - Energy - Environmental ... · PDF fileElectrochemical Laboratories 3 Specifications 7 Connections 8 Software 9 Corrosion 16 Voltammetry 17 Impedance

13

Battery discharge followed by EIS

• Galvanic Tutorial EIS• Auto R1R2C• Time Evolution

EIS spectrum

The battery is discharged at constant current. Galvanostatic impedance is performed at regular intervals. The R2value is plotted against time with "TimeEvolution".

Anodic stripping with Universal DifferentialPulse. Nitrogen bubbling, stirring andmercury drop renewal are all automated.The quantitative result can be calculatedfrom the peak height, the peak position orthe area between two potential limits.

Routine analysis with polarography

• Run External Utility• Chrono Amperometry• Pot. Universal DP• Auto Linear Extraction• Standard Calibration• Time Evolution

Chrono potentiometry

Monitoring plating bath efficiency

• Chrono Potentiometry• Pot. Coulometry• Current Efficiency• Time Evolution

Universal Differential Pulse

Pitting tests

• Pitting• Auto Traject• Last Point (pitting)• Time Evolution (pitting)• Time Evolution

(Repassivation)

An aliquot taken from the actual productionbath constitutes the sample. Constant potential deposition is followed by potentio-dynamic stripping. The ratio between thedeposition charge and the stripping chargemeasures the efficiency of the bath. Alarmthresholds can be set.

The sample is anodically polarised until pitting starts (current level). Then the potentialis scanned back cathodically in order todetermine the repassivation potential (current level).

Pitting test (voltammetry)

Electrochemistry with Time Evolution:

Page 15: Electrochemistry - Fuel cells - Energy - Environmental ... · PDF fileElectrochemical Laboratories 3 Specifications 7 Connections 8 Software 9 Corrosion 16 Voltammetry 17 Impedance

The electroactive surface is taken intoaccount in the calculation. The same experi-mental file can be used by several calcula-tion methods and their respective "TimeEvolution" methods so you can follow R1,R2 and C for each semicircle.It is also possible to follow the modulus orthe phase at a given frequency.

Auto R1R2C Fitting

Circular regression between two predefined frequency limits.

Standard Calibration

Interpolation through a calibrationcurve.

Quantitative calculation is provided eitherby standard addition or by calibration. Incalibration mode, linear as well as logarith-mic or exponential regression modes areavailable with blank subtraction if needed.Several species can be followed as severalcalculation methods and their respective"Time Evolution" methods can use the sameexperimental file.

Current Efficiency

Ratio between deposition and strippingcharges.

Last Point

Selection of the last point co-ordinate inanodic polarisation (potential).

Using a pair of experimental curves, a number of different indices featuring therespective anodic and cathodic charges canbe calculated. Another useful function allowsexperimental curves obtained each cycle tobe compared with a reference curve alreadyarchived.

The last potential of the anodic polarisationcorresponds to the potential at which the setcurrent limit is reached. In addition, bychoosing Auto Peak Analysis in combinationwith Time Evolution, you can follow themaximum current reached during the test.

14

a new world of expertise

Page 16: Electrochemistry - Fuel cells - Energy - Environmental ... · PDF fileElectrochemical Laboratories 3 Specifications 7 Connections 8 Software 9 Corrosion 16 Voltammetry 17 Impedance

15

VoltaMaster 4 step by step

You create a sequence to organise measurements.

This sequence includes calculations.

Real time plot during aquisition.

Automatic print out of calculations.

Display of results.

Printing of results.

Page 17: Electrochemistry - Fuel cells - Energy - Environmental ... · PDF fileElectrochemical Laboratories 3 Specifications 7 Connections 8 Software 9 Corrosion 16 Voltammetry 17 Impedance

Corrosionwith VoltaLab 21/10/40/50/80

Corrosion testsCorrosion tests typically consist of a Polarisationcurve, Tafel analysis, Pitting test, PolarisationResistance or Evans tests.

Polarisation curveIt is simple to obtain a polarisation curve accordingto ASTM G3 and G5, for instance. Both Tafel andStern calculations can be performed to achievecorrosion parameter determination.

Tafel analysisThe corrosion current density expressed in loss ofmetal thickness per year is determined from theTafel equation. The thermodynamic ba and bcparameters of the Butler Volmer equation are alsoobtained.

2nd Stern analysisA parabolic regression determines the Rp as theslope of the tangent of the voltammetric curve atthe zero-current potential.

Pitting testThe “pitting potential” of stainless steel correspondsto the potential at which the current starts toincrease on the anodic scan and the “repassivationpotential” corresponds to the potential at whichthe current becomes negligible on the reverse(cathodic) scan. A “repassivation potential” closeto the “pitting potential” indicates that the sampleis capable of reprotecting itself easily after pitting.

Polarisation resistance testThe Rp polarisation resistance helps to evaluatethe anti-corroding strength of a corrosion inhibitoror to study a uniform corrosion process. The Rpvariations versus time are automatically recorded.Each experimental point (Rp value and rest poten-tial) is obtained from one individual voltammetrywhich is automatically processed with selectablealgorithms (Linear, Stern, GFC etc.). Individualvoltammetries are also saved. Between two Rpdeterminations, the system is left at rest (the circuitis open) for a time delay set by the user.

Evans testCoupled corrosion is also called bimetallic corrosionor galvanic corrosion. It occurs when two differentmaterials subject to corrosion are in contact witheach other and with the same solution. The lessnoble material suffers from corrosion, as predictedby the thermodynamic potentials of these materials.Evans experiments determine the corrosion currentwhich is expected to take place at “rest” potentialtaking into account the areas. A variation of therelative surface area can be simulated in post-runprocessing.

16

Page 18: Electrochemistry - Fuel cells - Energy - Environmental ... · PDF fileElectrochemical Laboratories 3 Specifications 7 Connections 8 Software 9 Corrosion 16 Voltammetry 17 Impedance

17

Voltammetrywith VoltaLab 10/21/40/50/80

CV interactive control panelHold/Continue holds the potential/

continues to scan the potentialStart starts the active sequence Reverse reverses the scan directionModify modifies the potential set-points, the scan

rate, the number of cycles and clears the pageNext skips to the next method within the sequenceStop stops the experiment and opens the circuit

Interactive CVThe Interactive Cyclic Voltammetry method replacesthe need to use the front panel of the analoguepotentiostat with the additional advantage of adigital function as results are saved as files.Interactivity is available up to 300 mV/s. You operate a CV interactive as if you were using an analogue instrument. You can change parame-ters and also clear the memory (which corre-sponds to a “new” sheet if we compare it with achart recorder). It could not be more convenient.

Real-time displayYour instrument permanently displays and recordsthe current density (i), the working electrodepotential (E), the total charge (Q), the synchronisedadditional channel input (A/D IN) and the time (t)elapsed on the run bar. The experimental curve isalso plotted in real time. Even when you decide to“Hold” the potential, the data are saved. There isno maximum time or memory size limit! At theend of the experiment, you can extract the signifi-cant part of the experimental curve and save it asa separate file.

Be interactiveWhile running an interactive cyclic voltammetry,you can modify the scan rate and/or the potentialsettings and/or reverse the sweep direction and/orhold the potential for as long as you wish. You arein control!

Benefit fully from interactivityImagine that you are running a voltammetry. Youobserve a peak and want to start a chrono-coulometry immediately and at this exact peakpotential. It is child’s play with VoltaLab since rela-tive electrochemistry is combined with interactivity!

Relative electrochemistryThe Pot. Linear Voltammetry offers a very conven-ient specification: you can quote the initial poten-tial versus OCP and the final potential versus REF.Then you can polarise the electrode starting fromthis potential and finish recording your experiment.The benefit is that the potential is gradually drivenfrom OCP towards the starting potential of the CV.

Page 19: Electrochemistry - Fuel cells - Energy - Environmental ... · PDF fileElectrochemical Laboratories 3 Specifications 7 Connections 8 Software 9 Corrosion 16 Voltammetry 17 Impedance

Impedancewith VoltaLab 10/40/80

Expert EISOptimise your acquisition by taking advantage ofcurrent autoranging, the delay before integrationand the easy definition of sub-scans with individ-ual settings.

Real-time displayNyquist (-Zimaginary versus Zreal) or Bode (modulus and phase shift versus logarithm of fre-quency) with Dynamic EIS method and (Zreal, -Zimaginary) versus potential during a potentialscan at fixed frequency (Mott-Schottky type).

Electrochemical ImpedanceAny type of Potentiostatic or GalvanostaticElectrochemical Impedance Spectroscopy experi-ment can be performed.

EIS analysisAutomatic R1R2C equivalent circuitry fitting isprovided with a circular regression. The R1R2Cconventional model for a simple electrochemicalprocess is widely used to compare different sam-ples or processes. EIS files can be transferred to Z-View for future analysis.

Potentiostatic ImpedanceFor kinetics, dynamic EIS (Impedance) being thefastest mode.

Galvanostatic ImpedanceFor corrosion and battery testing.

Mott-Schottky (Capacitance)The Pot. Fixed Freq. EIS (Capacitance) methodprovides information about charge-transfer andadsorption mechanisms. The experimental fileincludes impedance data and the result of capaci-tance calculation plus DC potential and DC current.The voltammetry is recorded simultaneously alongwith the "Mott-Schottky" diagram.

EIS programming is made easy forFrequency scan at a single DC potential.Frequency scan at a single DC current.Potential scan at fixed frequency (Mott-Schottky experiment).Frequency scans at specified time intervals at a single DC potential or current.Frequency scans at different DC potentials from initial to final in preset potential steps.Frequency scans at different DC currents at different preset currents.Frequency scans at specified time intervals at OCP (in combination with OCP method)

at a single DC potential or current.

18

Page 20: Electrochemistry - Fuel cells - Energy - Environmental ... · PDF fileElectrochemical Laboratories 3 Specifications 7 Connections 8 Software 9 Corrosion 16 Voltammetry 17 Impedance

19

PolarographyWith VoltaLab 50/80

Square Wave VoltammetryFrom Square Wave Voltammetry to Triple NormalPulse Differential Voltammetry - every multipulsesignal used in analytical electrochemistry can beprogrammed with VoltaLab.

Real-time plotRun your experiment and observe the real-timedisplay of the differential current. Interactivitymeans you can jump to the next method or stop itif necessary.

Experiment and calculation settingsCreate a sequence to control the stand, performthe acquisition, automatically examine the peaksand print the results.

CalculationsEach element is independently analysed.Smoothing and blank subtraction are available.

Post-run processingYou may wish to validate your choices step bystep. Use “Differential Extraction” on the “rawdata” curves to evaluate how you can improve theacquisition by adjusting the sampling window. Use“Subtraction/Addition” to remove the experimentalblank from your sample curve. Use “Peak analysis”to examine your peak signals and adjust the settingsused for quantitative analysis.

PrintoutDate, time, sample identification, operator andsupervisor names, regression factor and file identi-fication for traceability purposes are printed inaddition to the value itself.

DatabaseWhen a new quantitative result is calculated, aVM4RESULTS.xls file is created/modified.VoltaMaster 4 saves the result in real mode(VoltaLab 50 and VoltaLab 80 only) and in virtualmode (every system). Anyone can review thebehaviour of the data without enteringVoltaMaster 4. Filters to sort the data from thedatabase and graphs on additional pages can berequested within the VM4RESULTS.xls file.

Page 21: Electrochemistry - Fuel cells - Energy - Environmental ... · PDF fileElectrochemical Laboratories 3 Specifications 7 Connections 8 Software 9 Corrosion 16 Voltammetry 17 Impedance

Real-time plotRun your experiment and observe the real-timedisplay of the differential measurement versuspotential or time. Intervene in order to jump to thenext method or stop if necessary. If you refer tothe graphic folder of the settings, the differential current measurement is taken between positionsrepresented by the red inverted triangles andquoted versus the potential imposed at the positionshown by the blue triangle.

SettingsDefine a Ramp, add a multipulse signal with 8levels on top and adjust the value and duration ofeach pulse individually. Click on Graphic to checkthe overall shape of the imposed signal. UniversalDifferential Pulse can be added in the sequencewith any Method available, regulation can bemaintained between methods with no gap! If indoubt, consult the Help file.

Universal Differential PulseIt is so simple to prepare a universal multipulseexperiment with the Pot. Universal DifferentialPulse method that what you get is - amazingly -what you want!

Post-run processingIn addition to the differential file, a raw data filerecords the current during the whole experimentwith a sampling rate equal to the acquisition period time, down to 500 µs. Post-run processingenables the user to recalculate any differentialcurve from the raw data, adjusting the “samplingwindow” and to extract any “Linear voltammetry”from it using the Linear extraction tool. Displaythem as you wish, extract the interesting parts,overlay curves, export them, calculate results.

Universal Differential Pulsewith VoltaLab 50/80

Universal Differential PulseThe principle is to define a combination of up to 8 levels of imposed potential (or current)versus time. Each step can last 255 times the acquisition period time (sampling rate). Thissampling rate can be selected from 0.5 ms to 999s. RECURRENT, Linear SCAN and NORMAL modes are available. In normal mode, the applied set point is reset to an initiallevel to “regenerate” the interface between each pulse.

20

Page 22: Electrochemistry - Fuel cells - Energy - Environmental ... · PDF fileElectrochemical Laboratories 3 Specifications 7 Connections 8 Software 9 Corrosion 16 Voltammetry 17 Impedance

Gal. Recurrent Differential PulseTo increase the performance of a battery, it is pos-sible to charge it under various conditions. A multilevel pulse galvanostatic signal optimisesthe charge. The Galvanostatic Recurrent DifferentialPulse method is ideal for preparing experimentslike this and combining them with galvanostaticexperiments without opening the circuitry.

Real-time plotRun your experiment and observe the real-timepotential display. Intervene to jump to the nextmethod or stop it if necessary.

Universal Differential PulseIt is so simple to prepare a universal multipulseexperiment with the Pot. Universal DifferentialPulses method that what you get is - amazingly -what you want!

SettingsDefine a maximum duration, set a potential limitand define a resolution time (equal to the shortestpulse you want to use) then build your multipulsesignal with 8 levels and adjust the height andduration of each pulse individually. Click on theGraphic to verify the overall shape of the imposedsignal. This method will charge the battery.

SequenceYou can create a sequence of alternate chargingand discharging. In addition, you may want toinsert electrochemical impedance measurement atrest after each cycle. Nothing could be more simple.

Post-run processingPost-run processing enables you to “Append” allthe curves and filter them in order to reduce thenumber of points to a convenient number withoutlosing information. This can be automated duringthe experiment.

21

Battery testingwith VoltaLab 80/50

Page 23: Electrochemistry - Fuel cells - Energy - Environmental ... · PDF fileElectrochemical Laboratories 3 Specifications 7 Connections 8 Software 9 Corrosion 16 Voltammetry 17 Impedance

DIDODCwith VoltaLab 40/80/50

Resistance monitoringThe cell resistance is measured, recorded andcompensated step by step during the experiment.The variations in this resistance can form a newinvestigation method.

With or without compensation?Many theories, especially in cyclic voltammetry,are only valid if the potential is driven linearly asa time function at the interface itself.Experimentally, the linearity is often not respectedbecause of the Ohmic Drop and, as a conse-quence, relevant potentials are shifted. WithOhmic Drop compensation, the peaks are sharper.

Dynamic Impedance Driven ODCis an innovative feature designed to compensateOhmic Drop. During the experiment, the “cell-elec-trolyte” resistance is measured step by step byimpedance. The OD is then calculated and the setpotential for the next step automatically adjusted.The imposed potential compensates this OD. Thisactive compensation is provided through algorith-mic regulation without any risk of oscillations. Lastbut not least, this is a software-selectable optioneffective up to 100 mV/s with autoranging forcurrent measurement.

Dynamic Impedance Driven OhmicDrop CompensationThis unique feature is a selectable option withinthe relevant methods.

SimplicityPrepare your Cyclic Voltammetry and select“Ohmic Drop compensation”. It is that simple.What you get is - amazingly - what you want!

Static ODCis based on an impedance measurement with anactive compensation provided through algorithmicregulation. It is effective up to 1000 mV/s withautoranging for current measurement.

Feedback ODCis available up to 20 V/s with automatic determi-nation of the cell resistance by impedance.

Mathematical ODC“Resistance subtraction” in post-run processing isalso provided for DC measurements.

How ODC worksThe Ohmic Drop is the product of the current which flowsthrough the resistance of the electrolyte between the refer-ence electrode and the electrochemically active interface of the working electrode. Due to the ohmic drop phenome-non, the potential at the interface is slightly different fromthe expected potential. Interface potential = (WORK-REF)potential - Ohmic Drop. The maximum resistance whichcan be compensated depends on the total current whichflows through the electrochemical cell, on the polarisationvoltage and on the compliance voltage.

22

Page 24: Electrochemistry - Fuel cells - Energy - Environmental ... · PDF fileElectrochemical Laboratories 3 Specifications 7 Connections 8 Software 9 Corrosion 16 Voltammetry 17 Impedance

23

Monitor barThe Monitor bar gives useful information between experiments. It displays the working elec-trode potential (in mV), plus the potentiostat status.As soon as an experiment starts, the Monitor baris replaced by the Run bar

All-in-oneA single software to perform, analyse and documentexperiments in order to prepare your publications.

Cell setupUse the cell setup to define your reference electrodeand parameters useful for autocalculations, forinstance in corrosion.

Multitasking You can drive up to 8 VoltaLab potentiostats simultaneously from a single PC. You can examinefiles which have already been acquired while theexperiment is still running.

HelpAn illustrated Help section contains recommenda-tions on how to prepare, run and examine experi-ments. A comprehensive set of demonstrationcurves and experimental method sequences is alsoavailable.

RCB200 The RCB200 ResistorCapacitor Box will help you become familiar withVoltaLab ElectrochemicalLaboratories and check theirmain technical specifications with “ready-to-use”sequences available in VoltaMaster 4.

Interactive real-time displayReal-time display is available at all times, even atmaximum sampling rate. You can skip to the nextmethod within the sequence, stop the experimentor modify any interactive setting.

VoltaMaster 4Electrochemical Software

Page 25: Electrochemistry - Fuel cells - Energy - Environmental ... · PDF fileElectrochemical Laboratories 3 Specifications 7 Connections 8 Software 9 Corrosion 16 Voltammetry 17 Impedance

Post-runEverything is ready for you to document yourexperiment and prepare your report.

Calculation routinesPeak analysis - Integration - Tafel analysis - Linearregression - Circular regression - R1R2C fitting forEIS - Stern analysis - Evans analysis - Coulometricdissolution - Resistance subtraction - StandardAddition - Standard Calibration - Sort by potential.

Export facilityThis exports the curve as displayed in Excel inorder to help you to transfer experimental data toother software. You can, for instance, transfer log(current) versus sqrt (time).

Result databaseEvery quantitative result is automatically recordedin an Excel database for optimum connection toLIMS systems.

“Intelligent filter”Linear Extraction reduces your file size without los-ing any information. You can also apply offsets toquote your potentials versus SHE, for example.And it can be automated!

Curve operationX Y1 Y2 representation - Zoom - Overlay/Remove- Linear extraction - Differential extraction -Potential reset/offset - Current reset/offset -Charge reset/offset - Time reset/offset - Curveaddition/subtraction - Append - Export (to Excel 97or higher) - Smoothing - Cursor - Title - Legend

Type barThe type bar is the most versatile tool for repre-senting your experimental curves. All parameterscan be displayed.

Curve save asTo give your most important files explicit names,independent from the sequence name.

“Results” folderEach curve has a “Results” folder where you canattach comments and save the results of the calcu-lations performed with the analysis tool. This infor-mation is saved and can be printed with the curve.Whenever you open a curve, the information youneed is there.

Experimental curves in ASCIIThey feature Potential, Current, Time, Resistance,Auxiliary, A/D IN, Frequency, Module, Phase,Zreal, -Zimaginary and Capacitance, dependingon method settings. Any data from one file can bedisplayed (as Y1 or Y2) versus any other datafrom this file (as X) with mathematical functions to process X, Y1 and Y2 such as log, sqrt, inv.

Post-run processing

24

Page 26: Electrochemistry - Fuel cells - Energy - Environmental ... · PDF fileElectrochemical Laboratories 3 Specifications 7 Connections 8 Software 9 Corrosion 16 Voltammetry 17 Impedance

25

Additional units

Analytical rotating disc standTo perform quantitative analysis with stripping cyclic voltammetry on a rotatingdisc electrode, the RDS010 is the obvious choice.

Voltage boosterThe HVB100 High Voltage Booster boosts your VoltaLab system compliance voltageup to ±100 V. Useful in organic electrochemistry or when a very large ohmicdrop needs to be compensated.

Current boosterHCB020: the ultimate choice for fuel cell investigations with galvanostatic expertEIS available under 20 A and current interrupt management.

Mercury drop electrode standTo perform stripping analysis and pulse polarography, the MDE150 PolarographicStand can be directly driven from VoltaMaster 4.

Potentiostats X,Y,VgVoltaLab 80 allows you to operate any of your potentiostats featuring potential andcurrent analogue output plus signal generator input with the “X,Y,Vg” instrumentsetup selection.

External unitAny type of external unit controlled by a RS232C (e.g. microbalance, burette,spectrometer) can be driven from VoltaMaster 4.

Quartz microbalanceWe recommend the PM-710 from Maxtek with its DI-10 DAC interface.

Combinations

BipotentiostatTo perform Ring Disc Rotating Electrode measurements, for example, use twoVoltaLab systems simultaneously. The WE1 and the WE2 currents are saved in thesame file thanks to the A/D IN channel for easy interpretation of your results.

MultipotentiostatYou can drive up to 8 potentiostats independentlyand simultaneously from one PC (USB/RS232required) with VoltaMaster 4.

External signal generatorAn external analogue signal generator can be usedfor instance to impose high scan rates or a specialwave form.

Volta

Lab

10Vo

ltaLa

b 40

Volta

Lab

50Vo

ltaLa

b 80

Volta

Lab

21

Additional units

Recommended

Possible

Page 27: Electrochemistry - Fuel cells - Energy - Environmental ... · PDF fileElectrochemical Laboratories 3 Specifications 7 Connections 8 Software 9 Corrosion 16 Voltammetry 17 Impedance

High voltage booster

The HVB100 boosts your compliance voltage upto ±100 V. Connect the HVB100 to your PGZxxxor PST050 Potentiostat and declare it in theVoltaMaster 4 setup. Every method is still available.This additional unit is useful in organic electro-chemistry or when a very large ohmic drop needsto be compensated. Compatible with VoltaLab 10,VoltaLab 40, VoltaLab 50 and VoltaLab 80.

Org

anic

s

Ordering informationHVB100 (230 V) R21V013HVB100 (115 V) R21V014

High current boostersFuel cellCapacitorsBatteryMolten salt

Ener

gy

Ordering informationHCB005 (230 V) R21V031HCB005 (115 V) R21V032HCB010 (230 V) R21V029HCB010 (115 V) R21V030HCB020 (230 V) R21V027HCB020 (115 V) R21V028

26

VoltaLab offers you three models, the HCB005,HCB010 and HCB020 which deliver up to 5, 10and 20 A respectively. Each model offers 2, 3 or4-pole connections in galvanostatic as well as inpotentiometric mode. Time resolution is availabledown to 0.5 ms. They are driven by a PGZ402(VoltaLab 80) and capable of ElectrochemicalImpedance measurement. Either WORK or AUXcan be grounded. They are ideal for fuel cell andenergy storage component tests.

High compliance voltagefor highly resistive media

HVB100High Voltage Booster

HCB020High Current Booster

Page 28: Electrochemistry - Fuel cells - Energy - Environmental ... · PDF fileElectrochemical Laboratories 3 Specifications 7 Connections 8 Software 9 Corrosion 16 Voltammetry 17 Impedance

27

The RDS010 Analytical Rotating Disc Stand stayssafely in place whenever you have to handle yoursample. It accommodates a Rotating DiscElectrode and solid electrodes very easily in its 4holes (14.5/23 sleeves). The rotation speed of theRDE is driven from VoltaMaster 4 with VoltaLab10/40/50/80. Ideal for setting up a routine analytical stand using a rotating disc electrode,this stand is also suitable for teaching. TheRDS010 offers precise and fully reproducibleexperimental conditions day after day.

The RDS010-Co comes with one Rotating DiscElectrode with a platinum disc tip (diameter = 5 mm), an Ag/AgCl reference electrode and itsdouble liquid junction protective tube plus a plat-inum wire counter electrode and a set of beakersand cables. The RDS010-Ba is delivered withoutany electrodes.

Rotating Disc Electrode Stand

Up to 5000 rpmBuilt-in rotationspeed controller

50 to 180 mlWorking cell volume

Rotation speedAdjustment from VoltaMaster 4 100 to 5000 rpmAccuracy on rpm ±0.1% External control (BNC) 0-5 V full scaleConnection to the potentiostat BNC

GeneralPower supply 115/230 Vac + 15-18%

47.5-63 HzSize & Weight 34 x 20 x 26 cm & 6.5 kg

RDS010Analytical Rotating Disc Stand

Ordering informationRDS010-Co (230 V) R21V021RDS010-Co (115 V) R21V022RDS010-Ba (230 V) R21V019RDS010-Ba (115 V) R21V020

Accessories for Nitrogen bubbling50 beakers with cover (polypropylene, 180 ml) X31V005BA-Nitrogen bubbler A30T460RA/CPRA-Stopcock for nitrogen inlet A30T400ES/46-Silicon tubing (2 m) int. diameter 4 mm A25X330

Page 29: Electrochemistry - Fuel cells - Energy - Environmental ... · PDF fileElectrochemical Laboratories 3 Specifications 7 Connections 8 Software 9 Corrosion 16 Voltammetry 17 Impedance

The MDE150 Polarographic Stand accommodateseither the MDE/HGDROP Hanging Mercury DropElectrode or the EDI101 Rotating Disc Electrodedriven from a separate CTV101 Speed ControlUnit. Nitrogen humidifier vessels prevent reductionof the sample volume due to evaporation. Theglass sample cell (volume = 5 ml) fits in placewithout any risk of the geometry of the electrodesbeing modified. Full automation is controlled fromVoltaMaster 4 with either VoltaLab 50 or VoltaLab80 regarding hammer stoke, mercury drop size(growth time), stirring, purging and blanketing.

Polarographic Stand

Pressurised HgDrop size set

from VM4

Automatic degassingVoltaMaster 4 switches automatically

from purging to blanketing

5 to 15 mlWorking cell volume

Magnetic stirrerDriven from VM4

GeneralConnection to the potentiostat DINLOCK6Power supply 115/230 Vac + 15-18%

47.5-63 HzSize & Weight 34 x 20 x 26 cm & 6.5 kg

ConsumablesTM020 Platinum electrode B18C002TR020 Ag/AgCl Reference Electrode B18C003EGM/AL010 Ionic-bridge for reference electrode A30T085Filling solution for reference electrode, 30 ml B22D004CP020 Polarographic cell, Standard, for MDE150 B22D001Adapter support for EDI/MDE150 A67A003

Ordering informationMDE150, 230 V A31A003MDE150, 115 V A31A004

In addition to the MDE150, the following kits are needed to obtain aHMDE.

MDE/HGDROP Mercury Drop Electrode Kit A31K003MDE/EL Reference and Counter Electrode Kit A31K002MDE/SET Setup Accessory Kit A31K001C505R DINLOCK6-M/1m/2PL259-BNC cable A95R505

How to select a standYou need a mercury drop electrode: MDE150. You needremote control degassing: MDE150. If you work on solidstate electrodes and you can handle the degassing manu-ally: RDS010 using the RDE as a very accurate stirrer oras the working electrode by itself.

28

MDE150Polarographic Stand

Page 30: Electrochemistry - Fuel cells - Energy - Environmental ... · PDF fileElectrochemical Laboratories 3 Specifications 7 Connections 8 Software 9 Corrosion 16 Voltammetry 17 Impedance

VoltaLab 50 is an analytical instrument designedto automate and simplify electrochemical analysis.When used in conjunction with the MDE150Polarographic Stand or the RDS010 Rotating DiscStand, it becomes an efficient analytical stationwith outstanding capabilities in terms of perform-ance (powerful supervisor level) and ease of use(secure operator level for routine analysis).

CalculationYou can calculate from Peak magnitudes, Peakpositions and Peak surfaces. This means that evenif the peak is rather weak, you can still performcalculations. This is often the case when the blankdoes not generate a well-defined peak. Standardaddition, calibration by addition and standardcalibration methods are available.

BlankYou can choose whether to take the blank intoaccount for the calculations. As a rule, the blank isused when the signal at no concentration is largecompared to the signal at maximum concentration.

Dilution factorsDilution factors are taken in account so that youget the results for your sample in addition to your“cell” result.

Selectable unitYou can select your own unit and a factor in orderto get a figure which makes sense in your analyti-cal context.

Calibration “curves”The full spectrums are recorded. In post-run pro-cessing, you can decide to recalculate versus theintegration of the peak rather than the peak mag-nitude. You will use the same set of spectrums.

“Curve” or “method”The calculation method concerns either a methodwithin the sequence or a file on your hard disk.This enables you to create a sequence which gen-erates the calibration “spectrums” independentlyfrom the sequence used to run your sample.

DatabaseA VM4RESULTS.xls file is automatically created/modified whenever a quantitative result is calculatedfrom VoltaMaster 4.

Voltammetric Trace Analysis

29

Trace analysis

TraceLab 50 • • • • 10 mA

VoltaLab 80 + MDE150 + MDE/HGDROP + MDE/EL+ MDE/SET+ C505R

• • • • • • • • • 1000 mA

VoltaLab 50 + MDE150 + MDE/HGDROP + MDE/E+ MDE/SET+ C505R

• • • • • • • • 1000 mA

VoltaLab 50 + RDS010-Co • • • • • • • 1000 mA

VoltaLab 80 + RDS010-Co • • • • • • • • 1000 mA

EIS

Pola

rogr

aphy

CP

CA

CV

CV

S

SQW

V (p

ulse

s)

CC

SA

PSA

Cyclic VoltammetryPolarographyUniversal PulseChrono PotentiometryCVSPSACCSA

Volta

Lab

50

Rota

ting

Dis

cEl

ectro

deM

ercu

ry D

rop

Elec

trode

Maxcurrent

Page 31: Electrochemistry - Fuel cells - Energy - Environmental ... · PDF fileElectrochemical Laboratories 3 Specifications 7 Connections 8 Software 9 Corrosion 16 Voltammetry 17 Impedance

Polarography

TraceLab 50Polarographic Laboratory

TraceLab 50 is the ideal system for research labo-ratories performing quantitative analyses of heavymetals and organic compounds at trace level. Itconsists of the POL150 Polarographic Analyserand MDE150 Polarographic Stand controlled byTraceMaster 5 Software. TraceMaster 5 Softwarehandles the MDE150 and automates standardaddition, calibration by addition and standardcalibration as well as peak auto recognition.Operations such as hammer stoke, mercury dropsize (growth time), stirring, purging and blanketingare all controlled from the PC via TraceMaster 5.

30

Detailed application notes are available from theTraceLab Resource Centre at

www.radiometer-analytical.com

The TraceLab range, which has applications in thefood and beverage industry, environment andwater, chemical and pharmaceutical research,consists of polarographic analysers for the deter-mination of heavy metals and organics at tracelevels.

Ordering information TraceLab 50 (230V) A31A007TraceLab 50 (115V) A31A008

Page 32: Electrochemistry - Fuel cells - Energy - Environmental ... · PDF fileElectrochemical Laboratories 3 Specifications 7 Connections 8 Software 9 Corrosion 16 Voltammetry 17 Impedance

31

A wide choice of quick-fit exchangeable tips instandard or custom materials: platinum, glassycarbon, gold etc. is available to fit the EDIRotating Disc Electrodes.

EAD10000 and EDI10000The EAD10000 is a rotating Ring & Disc electrode(Pt/Pt). The EDI1000 is a rotating disc electrodewith interchangeable tips. Both electrodes have an eccentricity of less than 1 mm.

Rotating Disc Electrodes

EDI101The EDI101 is a versatile and rugged rotatingdisc electrode ideal for use with any potentiostat/galvanostat. Precise mechanical design ensuresan eccentricity of less than ±0.1 mm for rotationspeeds from 100 rpm to maximum. An inert gasinlet is provided to protect the ball bearings inharsh operating conditions, extending electrodelife. It is available with a wide choice of quick-fitexchangeable tips in various materials: platinum,glassy carbon, gold etc.

Sleeve to fit BEC/EDI cell 14.5/23Eccentricity (100-5000 rpm) < ±1 mm

AccessoriesRDS010 EDI101 Stand (see p. 27)BEC/EDI Basic Electrochemical Cell (see p. 34)

Ordering information EDI101 A35T040CTV101 (230 V) A35T050CTV101 (115 V) A35T055

Up

to 5

000

rpm

Up

to 1

0000

rpm

Inte

rcha

ngea

ble

tips Standard (l = 40 mm)

Platinum ø5 mm A35T452Gold ø4 mm A35T456

Standard (l = 20 mm)Glassy Carbon ø3 mm A35T090Gold ø2 mm A35T110Gold ø5 mm A35T120Platinum ø2 mm A35T100Platinum ø5 mm A35T105Silver ø5 mm A35T150Stainless steel ø5 mm A35T420

Without materialSample holder tip A35T450Tip without hole A35T402

Page 33: Electrochemistry - Fuel cells - Energy - Environmental ... · PDF fileElectrochemical Laboratories 3 Specifications 7 Connections 8 Software 9 Corrosion 16 Voltammetry 17 Impedance

Display for rotation speed in rpm 4 digit LED Manual control 100 to 10000 rpmPC External control SUB-D9 maleExternal control (2 banana) 0-5 V full scaleAccuracy on rpm ±0.1%

The speed control unit controls the RDE rotationspeed. It offers accuracy better than ±0.1% forprecise and fully reproducible experimental condi-tions. The measured rotation speed is clearly displayed on a four-digit LCD. The speed controlunit can be directly driven from VoltaLab 10,VoltaLab 50, VoltaLab 40 and VoltaLab 80. Youcan program the variation of the rotation speedfrom one method to another method and achievea “Levitch” type experiment all in one go.

Display for rotation speed in rpm LCD Manual control 100 to 5000 rpmAccuracy on rpm ±0.1% External control (2 banana) 0-5 V full scale

AccessoriesXLRC 200 ml thermostated cell for EDI/EADS/EAD10000 Stand for EDI/EAD

Ordering informationTachyprocesseur (230 V) A35A300Tachyprocesseur (115 V) A35A310EAD10000 (Pt/Pt) A35A290EDI10000 A35T060

32

Speed control unitsfor rotating disc electrodes

TACHYPROCESSEURSpeed Control Unit for EDI10000

CTV101Speed Control Unit for EDI101

The Sample holder tip is designed to enable theuser to insert his own sample. A typical examplewould be a chemical deposit on the surface of ametal plate.

The tip without hole is designed to allow the use ofthe rotating disc electrode (EDI) as a very precisestirrer.

Available on special order (l = 20 mm) Antimony ø5 mm A35T310Cadmium ø5 mm A35T210Copper ø5 mm A35T130Graphite ø4 mm A35T140Iron ø5 mm A35T200Lead ø5 mm A35T300Nickel ø5 mm A35T160Tin ø5 mm A35T170Titanium ø3 mm A35T190Tungsten ø1 mm A35T320Zinc ø5 mm A35T080

The speed control unit controls the rotation speed.It offers precise and fully reproducible experiment-al conditions.

Sample holder tip

Page 34: Electrochemistry - Fuel cells - Energy - Environmental ... · PDF fileElectrochemical Laboratories 3 Specifications 7 Connections 8 Software 9 Corrosion 16 Voltammetry 17 Impedance

ReferenceCalomel B20B110Hg/Hg2SO4 B20B200Hg/HgO B20B400Ag/AgCl B20B300

Liquid Junction ProtectionTubesCeramic rod B40A610Reversed sleeve B40A710

33

ASTM cell

CNCThis ASTM standardcell supports cylindricalsamples for corrosiontests.

• Volume = 1000 ml• Two counter electrodes

(platinum cylinders)• One calomel reference

electrode• Adjustable Luggin capillary• One thermometer • One stainless

steel sample• One gas bubbler

Part Number A50T400

Data sheet D11V012*

Flow cell

C145/170You can circulate a liquid through thecell. The sample holder is designed fordisc samples.

• Volume = 250 ml• KEL-F sample holder

Disc diameter 1.4 cm Disc active area 0.95 cm2

• One platinum disc counter electrode

• One calomel reference electrode

• Luggin capillary• One flow-through

inlet/outlet

Part Number A50T110

Data sheet D11V013*

A large selectionof reference and metal electrodes isavailable together with cables andadapters as well as liquid junctionprotecting tubes with ceramic junction.

Electrodes

PlatinumWire B35M110Plate B35M140Disc B35M150Micro disc 10 µm B35A978

GoldMicrodisc 60 µm B35A999

Ask for our electrode catalogue, part no. D11M046

‘Guide to Reliable pH, Ion andConductivity Measurements’

Page 35: Electrochemistry - Fuel cells - Energy - Environmental ... · PDF fileElectrochemical Laboratories 3 Specifications 7 Connections 8 Software 9 Corrosion 16 Voltammetry 17 Impedance

Disc samples

CEC/THThermostated cell for corrosionwith sample holder for discs andplatinum disc counter electrode.Two optional sample holdersare available for coupled corrosion testing.

• Volume = 100 to 200 ml• Thermostated • KEL-F sample holder• For disc sample

Disc diameter 1.4 cmDisc active area 0.95 cm2

• One Pt disc counter electrode• One calomel reference electrode• Luggin capillary• One thermometer • One gas inlet/outlet

Part NumberB70A050

Data sheet D11V011*

Flat samples

CCTOIdeal for under coating corrosiontests. Corrosion cell for flat sampleswith a large surface.

• Volume = 100 to 200 ml• Thermostated• Sample active area 30 cm2

• One stainless steel disc counter electrode• One calomel reference electrode• Luggin capillary• One thermometer • One gas inlet/outlet

Part Number A50T950

CCTO/THThermostated CCTO cellPart Number A50T960

Data sheet D11V014*

Basic cell

BEC/EDIIdeal for teaching.Delivered with a bubbler,one calomel reference elec-trode and a platinum counterelectrode, the BEC/EDI cell is suit-able for use with rotating disc orsolid electrodes.

• Volume = 20 to 50 ml• Thermostated• One Pt counter electrode (wire)• One Calomel reference electrode• 5 holes - Sleeves 14.5/23• One bubbler• Suitable for Rotating Disc Electrode

Part Number X51V001

Data sheet D11V015*

CellsThe right cell for your application

A wide choiceVoltaLab offers a range of cells intended for thestudy of corrosion phenomena. All cells are fittedwith gas inlet and Luggin capillary and deliveredwith one reference and one counter electrode.Working and counter electrodes are locatedopposite each other to ensure good distribution ofelectrical fields. Radiometer Analytical cells can beassembled quickly and easily. For measurementsat high temperatures, special thermostated cellsare available. Ask for an individual data sheet.

PyrexCells are made of Pyrex glass which has the following composition:SiO2 80%; B2O3 13%; Al2O3 2.25%Fe2O3 0.05%; Na2O 3.5%; K2O 1.15%

34

*Data sheets are available from our website in PDF format.

Page 36: Electrochemistry - Fuel cells - Energy - Environmental ... · PDF fileElectrochemical Laboratories 3 Specifications 7 Connections 8 Software 9 Corrosion 16 Voltammetry 17 Impedance

D11V

026

© R

adio

met

er A

nalyt

ical S

AS

• Fr

ance

• 2

005-

06F

• A

ll rig

hts r

eser

ved

• Vo

ltaLa

b®is

a re

giste

red

trade

mar

k of

Rad

iom

eter

Ana

lytica

l SA

S •

Data

subj

ect t

o ch

ange

with

out n

otice

Radiometer Analytical SAS develops, manufactures and distributesan extensive range of electrochemical systems dedicated for routinetesting, research and teaching in the laboratory and on the plant.

By supplying instruments, software, sensors and calibration stand-ards, Radiometer Analytical SAS masters the complete measuringchain. Our customers obtain a reliable result at reasonable costthanks to all-in systems that are easy to use and maintain.

The company enjoys a reputation for excellence in the followingfields:

pH, ion and conductivity measurements: complete systems forreliable measurements in the field and in the lab including a widechoice of instruments, sensors and standards.

Titration: workstations customised to individual applications inclu-ding titrators, sample changers and dedicated software.

Voltammetry: all-in systems for electrochemical measurementsincluding potentiostats, impedance meters and powerful software

making use of techniques such as voltammetry, amperometry,coulometry, polarography and EIS.

Radiometer Analytical SAS has been building its expertise formore than sixty years since the company pioneered its very firstpH meter in Copenhagen, Denmark. It was strengthened by theacquisition of Tacussel, another leading name in electrochemicalinstrumentation. More recently Radiometer Analytical SAS joinedthe Danaher Corporation.

Based in Lyon, France, Radiometer Analytical SAS is representedthroughout the world by a network of experienced, factory-trained distributors, who can offer comprehensive appli-cations and after-sales service.

Radiometer Analytical SAS is ISO 9001 certified. In addition, ourReference Materials Laboratory is accredited by COFRAC(Comité Français d'Accréditation) for the calibration of referencematerials in pH and conductivity (Accreditation No. 2.1418).

Leading the field in electrochemistry

Radiometer Analytical SAS conçoit, fabrique et distribue unegamme complète d'ensembles électrochimiques de laboratoire et deterrain dédiés à l'analyse de routine, la recherche et l'enseignement.

En fournissant à ses utilisateurs des instruments de mesure, logiciels, capteurs et solutions d'étalonnage, Radiometer Analyti-cal SAS maîtrise l'ensemble de la chaîne de mesure. Cela garantit des résultats fiables avec des ensembles complets et faciles à utiliser et entretenir, à un coût raisonnable.

Notre société a acquis une solide réputation grâce à son savoir-faire dans les domaines suivants :

pH-métrie, ionométrie et conductimétrie : des ensembles completspour des mesures fiables en laboratoire ou sur le terrain comprenantun large choix d'instruments, de capteurs et de solutions étalons.

Titrage : des stations de travail adaptées en fonction de chaquetype d'application incluant des titrateurs, des passeurs d'échan-tillons et un logiciel spécifique.

Voltamétrie : des systèmes "tout-en-un" pour effectuer des mesuresélectrochimiques, comprenant des potentiostats, des impédance-

mètres et un logiciel puissant, et permettant l'utilisation de techniques telles que la voltamétrie, l'ampérométrie, la coulomé-trie, la polarographie et l'EIS.

Depuis la fabrication de son premier pH-mètre à Copenhague il y a plus de soixante ans, Radiometer Analytical SAS a constam-ment développé sa maîtrise et son expertise dans le domaine del'électrochimie et a renforcé sa réputation par l'acquisition deTacussel, une autre marque leader dans l'instrumentation électro-chimique. Plus récemment, Radiometer Analytical SAS a rejoint legroupe Danaher Corporation.

Basée à Villeurbanne (Rhône), Radiometer Analytical SAS estreprésentée par un vaste réseau de distributeurs en France etdans le monde, qui peuvent répondre rapidement à toutes lesdemandes commerciales, techniques, applicatives et de serviceaprès-vente.

Radiometer Analytical SAS est certifiée ISO 9001. De plus, notreLaboratoire Matériaux de Référence est accrédité par le COFRAC(Comité Français d'Accréditation) pour l'étalonnage de matériauxde référence pour les mesures de pH et de conductivité (Accrédita-tion N° 2.1418).

Un grand savoir-faire en électrochimie

Radiometer Analytical SAS entwickelt, fertigt und vertreibt einumfangreiches Programm elektrochemischer Laboranalysen-systeme, die für Routineprozesse genauso geeignet sind, wie fürAusbildung und Forschung.

Radiometer Analytical SAS bietet komplette Lösungen.Diese sind speziell den Kundenanforderungen angepasst undgewährleisten in der täglichen Routine einfache Handhabung,hohe Sicherheit und zuverlässige Analysenergebnisse.

Die Firma verfügt insbesondere auf folgenden Gebieten übereinen hervorragenden Ruf:

pH-, Ionen- und Leitfähigkeitsmessungen: MeterLab sind kom-plette Messplätze für zuverlässige Analysen im Feld und im Labor,mit einem breiten Angebot von Instrumenten, Sensoren und Stan-dards.

Titration: TitraLab sind leistungsfähige Titrationsautomaten, dieden individuellen Anforderungen angepasst werden können.Endpunkt-, Wendepunkt-, pH-stat- oder Karl Fischer- Titratoren,ausgestattet mit modernster Technik, stehen zur Verfügung. Soft-

waregesteuert lassen sich diese Titratoren kombinieren oderdurch Zusatzbüretten und einem Probenwechsler weiter ausbauen.

Elektrochemische Messsysteme: VoltaLab sind Komplettsysteme,die allen Anforderungen gerecht werden. Alle Potentiostate derVoltaLab- Serie werden über die gleiche Software gesteuert. Elek-trochemischen Methoden wie Voltammetrie, Amperometrie, Cou-lometrie oder EIS- Impedanzmessungen können auf diese Weisesinnvoll verknüpft werden.

Radiometer Analytical SAS profitiert von seinen im Verlauf vonüber 60 Jahren erworbenen Erfahrungen. Am Anfang stand derBau eines bahnbrechenden pH-Meters in Kopenhagen. Die Posi-tion der Firma wurde durch den Erwerb von Tacussel, einerbekannten Firma auf dem Gebiet der Elektrochemie, weitergestärkt. In jüngster Zeit schloss sich Radiometer Analytical SASder Danaher Corporation an.

Die von Lyon aus operierende Firma Radiometer Analytical SASwird weltweit durch ein Netz erfahrener, im Werk ausgebildeterFachkräfte vertreten, die vor Ort bei Anwendungen und Kunden-dienst umfangreiche Unterstützung gewähren können.

Führend auf dem Gebiet der Elektrochemie