ELECTRICAL SYMBOLS AND ABBREVIATIONS

8
XXX X SECTION REFERENCE - TOP DESIGNATES SECTION NUMBER - BOTTOM DESIGNATES SHEET NUMBER XXX X DETAIL REFERENCE - TOP DESIGNATES DETAIL NUMBER - BOTTOM DESIGNATES SHEET NUMBER DETAIL COVERAGE AREA FO T X E E EOL FATP DS H S B FSS RTS/I FACP FAAP SD R DH FS TS CM MM FA FA FA FA FA FA P S P S VC MI IC M M H VOLUME CONTROL PUBLIC ADDRESS AND MUSIC MASTER INTERCOM AND DIRECTORY UNIT INTERCOM UNIT - FLUSH MOUNTED MICROPHONE OUTLET - WALL MOUNTED MICROPHONE OUTLET - FLOOR MOUNTED SPEAKER - CEILING MOUNTED SPEAKER - WALL MOUNTED SPEAKER - BI-DIRECTIONAL PAGING - CEILING MOUNTED SPEAKER - BI-DIRECTIONAL PAGING - WALL MOUNTED CCTV CCTV MTV CCTV SCP MD K CR DR ES ML DC B B B REX DPS CCTV CAMERA - PAN-TILT-ZOOM - (X) INDICATES TYPE: (WP) WEATHER PROOF (VP) VANDAL PROOF X X X SECURITY CONTROL PANEL MOTION DETECTOR EXIT PUSHBUTTON KEY SWITCH STATION DOOR CONTACT DOOR CHIME DOOR BUZZER DOOR BELL CCVT MONITOR OUTLET CCVT COAXIAL CABLE OUTLET SECURITY AND ACCESS CONTROL DOOR STRIKE - ELECTRIC DOOR OPENER - ELECTRIC DOOR LOCK - MAGNETIC CCTV CAMERA - STATIONARY - (X) INDICATES TYPE: (WP) WEATHER PROOF (VP) VANDAL PROOF SECURITY CARD READER - (X) INDICATES TYPE: (WP) WEATHER PROOF (VP) VANDAL PROOF REQUEST FOR EXIT DOOR POSITION SWITCH X X X X X X END OF LINE RESISTOR TRANSPONDER PANEL SMOKE DAMPER FAN SHUTDOWN RELAY SPRINKLER FLOW SWITCH MAGNETIC DOOR HOLDER SPRINKLER TAMPER SWITCH FIRE SUPPRESSION CONTROL PANEL CONTROL PANEL ANNUNCIATOR PANEL REMOTE TEST SWITCH AND / OR INDICATOR MONITOR MODULE - ADDRESSABLE CONTROL MODULE - ADDRESSABLE FIRE ALARM HORN / STROBE - CEILING MOUNTED - (X) INDICATES STROBE CANDELA RATING FIRE ALARM HORN / STROBE - WALL MOUNTED 6'-8" AFF OR 6" BELOW CEILING, WHICHEVER IS LOWER - (X) INDICATES STROBE CANDELA RATING PULL STATION - MOUNTED 4'-0" AFF FIRE ALARM HORN - CEILING MOUNTED - (X) INDICATES HORN DECIBEL RATING FIRE ALARM STROBE - CEILING MOUNTED - (X) INDICATES STROBE CANDELA RATING FIRE ALARM HORN - WALL MOUNTED 6'-8" AFF OR 6" BELOW CEILING, WHICHEVER IS LOWER - (X) INDICATES HORN DECIBEL RATING FIRE ALARM STROBE - WALL MOUNTED 6'-8" AFF OR 6" BELOW CEILING, WHICHEVER IS LOWER - (X) INDICATES STROBE CANDELA RATING SMOKE DETECTOR - DUCT - PHOTOELECTRIC - INTELLIGENT - LINE INDICATES SENSING DIRECTION HEAT DETECTOR - INTELLIGENT - (E) INDICATES ELEVATOR SHUTDOWN OPTION SMOKE DETECTOR - PHOTOELECTRIC - INTELLIGENT - (E) INDICATES ELEVATOR RECALL OPTION SMOKE DETECTOR - BEAM - (X) INDICATES UNIT TYPE: (S) SENDING UNIT (R) RECEIVING UNIT FIRE ALARM X-XA (X) (X) XXX XXX X XA XAF TC TO XA OVERLOAD RELAY FUSE - (XA) INDICATES RATING SWITCH - UN-FUSED CUTOUT - (XAF) INDICATES FRAME SIZE SWITCH - FUSED CUTOUT - (XA) INDICATES RATING VARIABLE FREQUENCY DRIVE - (X) INDICATES MOTOR CONTROLLED X Y X Y XAF XAT XAF XA XA XP T / XXX XXXKVA XXXV, XPH, XW PRI XXXY / XXXV, XPH, XW SEC Y XA PANELBOARD - TOP DESIGNATES PANELBOARD TYPE - BOTTOM DESIGNATES PANELBOARD ID GENERATOR SHUNT TRIP RESISTOR STRESS CONE POTHEAD ONE LINE DIAGRAM MOTOR STARTER AND DISCONNECT COMBINATION - MAGNETIC - (X) INDICATES TYPE: (2S2W) 2 SPEED, 2 WINDING (2S1W) 2 SPEED, 1 WINDING (CB) CIRCUIT BREAKER (F) FUSED DISCONNECT SWITCH (FVNR) FULL VOLTAGE NON-REVERSING (FVR) FULL VOLTAGE REVERSING (NEMA1) NEMA STARTER SIZE (RV) REDUCED VOLTAGE STARTER - (Y) INDICATES MOTOR CONTROLLED MOTOR STARTER - MAGNETIC - (X) INDICATES TYPE: (2S2W) 2 SPEED, 2 WINDING (2S1W) 2 SPEED, 1 WINDING (FVNR) FULL VOLTAGE NON-REVERSING (FVR) FULL VOLTAGE REVERSING (NEMA1) NEMA STARTER SIZE (RV) REDUCED VOLTAGE STARTER - (Y) INDICATES MOTOR CONTROLLED CIRCUIT BREAKER - (XA) INDICATES TRIP SIZE - (XP) INDICATES NUMBER OF POLES TRANSFORMER - CURRENT - ((X)) INDICATES QUANTITY - (X-XA) INDICATES RATIO TRANSFORMER - POTENTIAL - ((X)) INDICATES QUANTITY TRANSFORMER - DRY TYPE, UOI - (XXX) INDICATES EQUIPMENT IDENTIFICATION - (XXXKVA) INDICATES RATING - (XXXV, XPH, XW PRI) INDICATES PRIMARY VOLTAGE, PHASE, AND WIRES - (XXXY / XXXV, XPH, XW SEC) INDICATES SECONDARY VOLTAGE, PHASE, AND WIRES GROUND FAULT CIRCUIT INTERRUPTER - PERSONAL PROTECTION LIGHTNING ARRESTER WITH GROUND CONNECTION TO PROTECT ALL PHASES GROUND CONNECTION TO SYSTEM AND / OR EQUIPMENT CONTACT - NORMALLY CLOSED - (TO) INDICATES TIMED OPENING OPTION CONTACT - NORMALLY OPEN - (TC) INDICATES TIMED CLOSING OPTION DISCONNECT SWITCH - CIRCUIT BREAKER - (XAF) INDICATES FRAME SIZE - (XAT) INDICATES TRIP SIZE - SIZE AS INDICATED ON DRAWINGS DISCONNECT SWITCH - FUSED - (XAF) INDICATES FRAME SIZE - (XA) INDICATES FUSE RATING - SIZE AS INDICATED ON DRAWINGS DISCONNECT SWITCH - NON-FUSED - (XA) INDICATES RATING - SIZE AS INDICATED ON DRAWINGS AUTO-TRANSFER SWITCH VOICE/DATA OUTLET - (X) INDICATES QUANTITY: (D) INDICATES DATA (V) INDICATES VOICE (B) INDICATES BLANK UNDERGROUND FIBER OPTIC CABLE OVERHEAD FIBER OPTIC CABLE UNDERGROUND TELECOMMUNICATIONS CABLE OR DUCTBANK OVERHEAD TELECOMMUNICATIONS CABLE VOICE/DATA VOICE/DATA OUTLET WITH JACK - WALL MOUNTED PHONE - 48" AFF ANTENNA SYSTEM MASTER OUTLET (MATV) ANTENNA SYSTEM OUTLET (CATV) VOICE/DATA OUTLET - CEILING MOUNTED - (X) INDICATES QUANTITY: (D) INDICATES DATA (V) INDICATES VOICE (B) INDICATES BLANK TV TV FO T M W C X X LIGHTNING PROTECTION / GROUNDING CABLE GROUNDING GROUND CONDUCTOR SPARE COIL EXOTHERMIC CONNECTION - WELD OR BOLTED AS INDICATED ON DRAWINGS GROUND CONNECTION TO STRUCTURAL STEEL GROUND TEST STATION GROUND ROD VFD F CB ST GFCI G X X Y X X X X X X X X X X X EQUIPMENT REFERENCE - TOP DESIGNATES EQUIPMENT TYPE: (LP) LIGHTING PANEL (MDP) MAIN DISTRIBUTION PANEL (MSB) MAIN SWITCHBOARD PANEL (PP) POWER PANEL (RC) RELAY CABINET (RP) RECEPTACLE PANEL (LCP) LIGHTING CONTROL PANEL (T) TRANSFORMER - BOTTOM DESIGNATES EQUIPMENT ID ELECTRICAL BOX - FLOOR MOUNTED - POKE THRU - OUTLET TYPES REQUIRED AT EACH BOX AS INDICATED ON DRAWINGS WIRING DEVICES MOTOR STARTERS AND DISCONNECTS EQUIPMENT AND PANELBOARDS JUNCTION BOX CEILING MOUNTED MOTOR STARTER - MANUAL MOTOR STARTER - MAGNETIC - (X) INDICATES MOTOR STARTER CONTROLLED (SEE SCHEDULE) METER GENERATOR SURFACE OR SUSPENDED MOUNTED CONDUIT UNDERGROUND OR UNDERFLOOR CONDUIT OR DUCTBANK UNDERGROUND POWER CONDUCTOR OR DUCTBANK OVERHEAD POWER CONDUCTOR RACEWAYS AND BOXES CURRENT TRANSFORMER CABINET DISCONNECT SWITCH - FUSED - (X) INDICATES MOTOR FED BY SWITCH DISCONNECT SWITCH - (X) INDICATES MOTOR FED BY SWITCH DUPLEX RECEPTACLE - MOUNTED 1'-6" AFF, UOI - (X) INDICATES CIRCUIT NUMBER (PANEL BOUNDARY AS INDICATED ON DRAWINGS) - (Y) INDICATES TYPE: (D)DEDICATED (DD)DOUBLE DUPLEX (GFCI) GROUND FAULT CIRCUIT INTERRUPTING (WP) WEATHERPROOF (WR) WEATHER RESISTANT COMBINATION MOTOR STARTER - (X) INDICATES MOTOR STARTER CONTROLLED (SEE SCHEDULE) TRANSFORMER - PAD MOUNTED TRANSFORMER - MOUNTED ON 4" CONCRETE PAD, UOI - (X) INDICATES MOUNTING TYPE: (W) WALL (S) SURFACE BRANCH PANELBOARD - SURFACE MOUNTED - (SEE SCHEDULE) BRANCH PANELBOARD - RECESSED MOUNTED - (SEE SCHEDULE) MOTOR CONNECTION - (X) INDICATES MOTOR IDENTIFICATION (SEE SCHEDULE) SPECIAL PURPOSE OUTLET - (X) INDICATES DEVICE IDENTIFICATION (SEE SCHEDULE) MULTI-OUTLET RACEWAY ASSEMBLY - WALL MOUNTED 1'-6" AFF, UOI - (X) INDICATES TYPE (SEE SPECIFICATION) ELECTRICAL BOX - FLOOR MOUNTED - FLUSH - OUTLET TYPES REQUIRED AT EACH BOX AS INDICATED ON DRAWINGS DUPLEX RECEPTACLE - MOUNTED FLUSH IN CEILING - (X) INDICATES CIRCUIT NUMBER (PANEL BOUNDARY AS INDICATED ON DRAWINGS) DUPLEX RECEPTACLE - MOUNTED FLUSH IN COUNTERTOP - (X) INDICATES CIRCUIT NUMBER (PANEL BOUNDARY AS INDICATED ON DRAWINGS) DUPLEX RECEPTACLE - TOP HALF SWITCHED - MOUNTED 1'-6" AFF, UOI - (X) INDICATES CIRCUIT NUMBER (PANEL BOUNDARY AS INDICATED ON DRAWINGS) DUPLEX RECEPTACLE MOUNTED 6" ABOVE COUNTER BACKSPLASH, UOI - (X) INDICATES CIRCUIT NUMBER (PANEL BOUNDARY AS INDICATED ON DRAWINGS) DISTRIBUTION PANELBOARD - (SEE ONE-LINE) XX/X HAND DRYER CONNECTION - PROVIDE JUNCTION BOX FOR WIRING TERMINATIONS AND 30A MOTOR RATED SWITCH FOR DISCONNECT CT G M F X F P E E M C S J EXIT LIGHT FIXTURE - END MOUNTED - SHADING INDICATES FACE(S) - ARROW(S) AND FACE(S) AS INDICATED ON DRAWINGS X X X X X X ta ra oa dal ca A-1b Xa X UNDERGROUND LIGHTING CONDUCTOR OVERHEAD LIGHTING CONDUCTOR LIGHTING CONTROL LIGHTING FIXTURE DESIGNATIONS LIGHTING FIXTURES STRIP OR UNDER CABINET DOUBLE HEAD SPOT OR FLOOD SINGLE HEAD SPOT OR FLOOD IN-GROUND OR IN-FLOOR MOUNTED POST TOP MOUNTED POLE MOUNTED WITH ARM WALL MOUNTED RECESS MOUNTED SURFACE MOUNTED EMERGENCY BATTERY REMOTE - DUAL LIGHTING HEADS EMERGENCY BATTERY REMOTE - SINGLE LIGHTING HEAD EMERGENCY BATTERY UNIT - DUAL LIGHTING HEADS RECESS MOUNTED ACCENT - CHEVRON INDICATES DIRECTION OF ILLUMINATION SURFACE MOUNTED ACCENT - CHEVRON INDICATES DIRECTION OF ILLUMINATION PHOTOCELL - (X) INDICATES TYPE (SEE SCHEDULE) TIME CLOCK - (X) INDICATES TYPE (SEE SCHEDULE) CONTACTOR - (X) INDICATES TYPE (SEE SCHEDULE) DAYLIGHT SENSOR - (X) INDICATES TYPE (SEE SCHEDULE) TIME CLOCK DESIGNATION (SEE SCHEDULE) TIME CLOCK CONTROLLED RELAY DESIGNATION CONTROLLING CIRCUIT OR PORTION OF CIRCUIT LOW VOLTAGE RELAY CONTROLLED VIA RELAY CABINET SPECIFIC DEVICE DESIGNATION CONTROLLING CIRCUIT OR PORTION OF CIRCUIT OCCUPANCY SENSOR CONTROLLED DIMMER CHANNEL CABINET DESIGNATION CONTROLLED VIA ELECTRONIC DIMMING SYSTEM CONTACTOR DESIGNATION (SEE SCHEDULE) CONTROLLED VIA CONTACTOR OCCUPANCY SENSOR - CEILING MOUNTED - (X) INDICATES TYPE (SEE SCHEDULE) - CHEVRON(S) INDICATE SENSING DIRECTION(S) OCCUPANCY SENSOR - WALL MOUNTED 3'-8" AFF, UOI - (X) INDICATES TYPE (SEE SCHEDULE) WALL BOX DIMMER STATION - (3) INDICATES 3-WAY DIMMER SWITCH - MOMENTARY CONTACT - MOUNTED 3'-8" AFF, UOI - (X) INDICATES SYSTEM DESIGNATION SWITCH - MOUNTED 3'-8" AFF, UOI - (a) INDICATES SWITCH DESIGNATION - SINGLE POLE, UOI - (X) INDICATES SWITCH TYPE: (2) TWO POLE (3) THREE WAY (4) FOUR WAY (DLS) DUAL LEVEL SWITCH (K) KEY OPERATED (P) WITH PILOT LIGHT (T) TIMER LIGHTING TRACK - LENGTH AS INDICATED ON DRAWINGS - NUMBER AND DIRECTION OF FIXTURES AS INDICATED ON DRAWINGS AND / OR SCHEDULE EXIT LIGHT FIXTURE - CEILING MOUNTED - SHADING INDICATES FACE(S) - ARROW(S) AND FACE(S) AS INDICATED ON DRAWINGS PARTIAL SHADING INDICATES FIXTURE PARTIALLY WIRED TO EMERGENCY OR NIGHT LIGHTING CIRCUIT SHADING INDICATES FIXTURE FULLY WIRED TO EMERGENCY OR NIGHT LIGHTING CIRCUIT TYPICAL AT EACH FIXTURE LOCATION LIGHT FIXTURE DESIGNATION - (A) INDICATES FIXTURE TYPE (SEE SCHEDULE) - (1) INDICATES CIRCUIT NUMBER (PANEL BOUNDS AS INDICATED ON DRAWINGS) - (b) INDICATES CONTROL DESIGNATION (IF NOT INDICATED, CONTROLLED VIA SWITCH AT ROOM ENTRY) SUSPENDED, PENDENT, CHAIN, STEM, OR CABLE HUNG D OS L L DS OS C T PC 1P 2P 3P 4P 1P,1W 1P,2W 2P,2W 2P,3W 3P,2W 3P,3W 3P,4W 4P,4W A AC AF AFF AFG AIC AL AS AT ARCH ATS A / V B BF BFF BFG BLDG C CAT CATV CB CKT CLG CO CT CU CL D DC DD DR DISC DW DWG E EC EMT ETR ERL ERLD EWC EX FA FLA FO FPC GC GFCI GFPE GND GRC HH HP HVAC HZ JB KVA KVAR KW LP LS LTG LV MC MCA MCC MDP MISC MH MLO MTD MTG MTS MW N / A MV NC NEC NIC NO # NTS P PB PC PH PNL PP PR PRI PVC REC REF RSC SC SEC SN SP SS ST STP SUSP SW SWBD T TC TCI TELE / DATA TEL TELECOM TP TYP UG UTP UOI V W WA WP XFMR XR XV Y ZAM - KILOVOLT AMPERE REACTIVE - KILOWATT - LIGHTING PANEL - LIMIT SWITCH - LIGHTING - LOW VOLTAGE - MECHANICAL CONTRACTOR - MINIMUM CIRCUIT AMPS - MOTOR CONTROL CENTER - MAIN DISTRIBUTION PANEL - MISCELLANEOUS - MANHOLE - MAIN LUGS ONLY - MOUNTED - MOUNTING - MANUAL TRANSFER SWITCH - MICROWAVE - NOT APPLICABLE - MEDIUM VOLTAGE - NORMALLY CLOSED - NATIONAL ELECTRIC CODE - NOT IN CONTRACT - NORMALLY OPEN - NUMBER - NOT TO SCALE - POLE - PULL BOX - PLUMBING SYSTEM CONTRACTOR - PHASE - PANEL OR PANELBOARD - POWER PANEL - PAIR - PRIMARY - POLYVINYL CHLORIDE - RECESSED - REFRIGERATOR - RIGID STEEL CONDUIT - SECURITY CONTRACTOR - SECONDARY - SOLID NEUTRAL - SPARE - STAINLESS STEEL - SHUNT TRIP - SHIELDED TWISTED PAIR - SUSPENDED - SWITCH - SWITCHBOARD - TAMPER RESISTANT SAFETY RECEPTACLE - TELEPHONE CABINET - TELECOMMUNICATIONS CABLING INSTALLER - TELEPHONE / DATA - TELEPHONE - TELECOMMUNICATIONS - TWISTED PAIR - TYPICAL - UNDERGROUND - UNSHIELDED TWISTED PAIR - UNLESS OTHERWISE INDICATED - VOLT - WATT - WASHER - WEATHERPROOF - TRANSFORMER - XRAY - XRAY VIEWER - WYE - ZONE ADAPTER MODULE - ONE POLE - TWO POLE - THREE POLE - FOUR POLE - ONE POLE, ONE WIRE - ONE POLE, TWO WIRE - TWO POLE, TWO WIRE - TWO POLE, THREE WIRE - THREE POLE, TWO WIRE - THREE POLE, THREE WIRE - THREE POLE, FOUR WIRE - FOUR POLE, FOUR WIRE - AMPERE - ALTERNATING CURRENT - AMPERE FRAME - ABOVE FINISHED FLOOR - ABOVE FINISHED GRADE - AMPERE INTERRUPTING CAPACITY - ALUMINUM - AMP SWITCH - AMP TRIP - ARCHITECT - AUTOMATIC TRANSFER SWITCH - AUDIO VISUAL - PEDESTAL MOUNTED ON BENCH TOP - BELOW FLOOR - BELOW FINISHED FLOOR - BELOW FINISHED GRADE - BUILDING - CONDUIT - CATALOG - CABLE TELEVISION - CIRCUIT BREAKER - CIRCUIT - CEILING MOUNTED - COPIER - CURRENT TRANSFORMER - COPPER - CENTERLINE - DEDICATED DEVICE - DIRECT CURRENT - DOUBLE DUPLEX - DRYER - DELTA - DISCONNECT - DISHWASHER - DRAWING - EMERGENCY - ELECTRICAL CONTRACTOR - ELECTRIC METALLIC TUBING - EXISTING TO REMAIN - EXISTING TO BE RELOCATED - RELOCATED EQUIPMENT'S NEW LOCATION - ELECTRIC WATER COOLER - EXISTING - FIRE ALARM - FULL LOAD AMPS - FIBER OPTIC - FIRE PROTECTION CONTRACTOR - GENERAL CONTRACTOR - GROUND FAULT INTERRUPTER - GROUND FAULT PROTECTION EQUIPMENT - GROUND - GALVANIZED RIGID CONDUIT - HANDHOLE - HORSEPOWER - HEATING, VENTILATING, AND AIR CONDITIONING - HERTZ (CYCLE) PER SECOND - JUNCTION BOX - KILOVOLT AMPERE ELECTRICAL SYMBOLS AND ABBREVIATIONS CONDUCTORS AND WIRING GENERAL SYMBOLS ELECTRICAL ABBREVIATIONS NOTE : NOT ALL SYMBOLS AND ABBREVIATIONS INDICATED HERE ARE USED IN DRAWINGS AND MAY NOT APPLY TO CURRENT PROJECT. ADDITIONAL SYMBOLS MAY BE INDICATED ON DRAWINGS. NOTE: AT THE TIME OF BUILDING PERMIT APPLICATION, THE ARCHITECT HAS NOT BEEN SO EMPLOYED TO FURNISH CONSTRUCTION OBSERVATION OR CONSTRUCTION ADMINISTRATION SERVICES. THE ARCHITECT HAS NO KNOWLEDGE OF THE START OF CONSTRUCTION NOR DOES HE HAVE KNOWLEDGE OF ANY OTHER REGISTERED ARCHITECT BEING SO EMPLOYED TO FURNISH CONSTRUCTION OBSERVATION OR CONSTRUCTION ADMINISTRATION SERVICES. CHECKED BY: DRAWN BY: DATE: SHEET P.352.378.4400 F.352.377.5378 1628 NW 6TH STREET GAINESVILLE FL 32609 ARCHITECTS & PLANNERS FL CERTIFICATE SVM SKINNER VIGNOLA McLEAN, INC. FOR ALL REPORTS, PLANS, SPECIFICATIONS, COMPUTER FILES, FIELD DATA, NOTES & OTHER DOCUMENTS & INSTRUMENTS PREPARED BY THE DESIGN PROFESSIONAL AS INSTRUMENTS OF SERVICE SHALL REMAIN THE PROPERTY OF THE DESIGN PROFESSIONAL. THE DESIGN PROFESSIONAL SHALL RETAIN ALL COMMON LAW, STATUTORY & OTHER RESERVED RIGHTS, INCLUDING THE COPYRIGHT THERETO. USE OF THESE DOCUMENTS FOR ANY PURPOSE OR PROJECT OTHER THAN THE PROJECT WHICH IS SUBJECT OF THE AGREEMENT IS UNLAWFUL. AA3478 PROJECT LOCATION: Alexander H. Parrish 87322 AHP 2300 Maitland Center Parkway Suite 210 Maitland, FL 32751-7411 407 / 659 6500 407 / 659 0609 fax www.graef-usa.com CERT # 4270 2300 Maitland Center Parkway Suite 210 Maitland, FL 32751-7411 407 / 659 6500 407 / 659 0609 fax www.graef-usa.com CERT # 4270 1/28/2020 3:35:57 PM C:\Users\2044\Documents\20154111_E20_2044.rvt 10/28/2019 E0.1 ELECTRICAL SYMBOLS AND ABBREVIATIONS COOPER HALL RENOVATION AT CAMP BLANDING JOINT TRAINING CENTER (CBJTC) CLAY COUNTY STARKE, FL DESIGN PHASE: BID DOCUMENTS AEV 01318 R E V I S I O N S

Transcript of ELECTRICAL SYMBOLS AND ABBREVIATIONS

XXX

XSECTION REFERENCE- TOP DESIGNATES SECTION NUMBER- BOTTOM DESIGNATES SHEET NUMBER

XXX

X DETAIL REFERENCE

- TOP DESIGNATES DETAIL NUMBER

- BOTTOM DESIGNATES SHEET NUMBER

DETAIL COVERAGE AREA

FO

T

X

E

E

EOL

FATP

DS

H

S

BFSS

RTS/I

FACP

FAAP

SD

R

DH

FS

TS

CM

MM

FA

FA

FA

FA

FA

FA

P

S

P

S

VC

MI

IC

M

M

H

VOLUME CONTROL

PUBLIC ADDRESS AND MUSIC

MASTER INTERCOMAND DIRECTORY UNIT

INTERCOM UNIT- FLUSH MOUNTED

MICROPHONE OUTLET- WALL MOUNTED

MICROPHONE OUTLET- FLOOR MOUNTED

SPEAKER- CEILING MOUNTED

SPEAKER- WALL MOUNTED SPEAKER

- BI-DIRECTIONAL PAGING- CEILING MOUNTED

SPEAKER- BI-DIRECTIONAL PAGING- WALL MOUNTED

CCTV

CCTV

MTV

CCTV

SCP

MD

K

CR

DR

ES

ML

DC

B

B

B

REX

DPS

CCTV CAMERA- PAN-TILT-ZOOM- (X) INDICATES TYPE: (WP) WEATHER PROOF (VP) VANDAL PROOF

X

X

X

SECURITY CONTROL PANEL

MOTION DETECTOR

EXIT PUSHBUTTON

KEY SWITCH STATION

DOOR CONTACT

DOOR CHIME

DOOR BUZZER

DOOR BELL

CCVT MONITOR OUTLET

CCVT COAXIAL CABLE OUTLET

SECURITY AND ACCESS CONTROL

DOOR STRIKE- ELECTRIC

DOOR OPENER- ELECTRIC

DOOR LOCK- MAGNETIC

CCTV CAMERA- STATIONARY- (X) INDICATES TYPE: (WP) WEATHER PROOF (VP) VANDAL PROOF

SECURITY CARD READER- (X) INDICATES TYPE: (WP) WEATHER PROOF (VP) VANDAL PROOF

REQUEST FOR EXIT

DOOR POSITION SWITCH

X

X

X

X

X

X

END OF LINE RESISTOR

TRANSPONDER PANEL

SMOKE DAMPER

FAN SHUTDOWN RELAY

SPRINKLER FLOW SWITCH

MAGNETIC DOOR HOLDER

SPRINKLER TAMPER SWITCH

FIRE SUPPRESSIONCONTROL PANEL

CONTROL PANEL

ANNUNCIATOR PANEL

REMOTE TEST SWITCHAND / OR INDICATOR

MONITOR MODULE- ADDRESSABLE

CONTROL MODULE- ADDRESSABLE

FIRE ALARM HORN / STROBE- CEILING MOUNTED- (X) INDICATES STROBE CANDELA RATING

FIRE ALARM HORN / STROBE- WALL MOUNTED 6'-8" AFF OR 6" BELOW CEILING, WHICHEVER IS LOWER- (X) INDICATES STROBE CANDELA RATING

PULL STATION- MOUNTED 4'-0" AFF

FIRE ALARM HORN- CEILING MOUNTED- (X) INDICATES HORN DECIBEL RATING

FIRE ALARM STROBE- CEILING MOUNTED- (X) INDICATES STROBE CANDELA RATING

FIRE ALARM HORN- WALL MOUNTED 6'-8" AFF OR 6" BELOW CEILING, WHICHEVER IS LOWER- (X) INDICATES HORN DECIBEL RATING

FIRE ALARM STROBE- WALL MOUNTED 6'-8" AFF OR 6" BELOW CEILING, WHICHEVER IS LOWER- (X) INDICATES STROBE CANDELA RATING

SMOKE DETECTOR- DUCT- PHOTOELECTRIC- INTELLIGENT- LINE INDICATES SENSING DIRECTION

HEAT DETECTOR- INTELLIGENT- (E) INDICATES ELEVATOR SHUTDOWN OPTION

SMOKE DETECTOR- PHOTOELECTRIC- INTELLIGENT- (E) INDICATES ELEVATOR RECALL OPTION

SMOKE DETECTOR- BEAM- (X) INDICATES UNIT TYPE: (S) SENDING UNIT (R) RECEIVING UNIT

FIRE ALARM

X-XA

(X)

(X)

XXX

XXX

X

XA

XAF

TC

TO

XA

OVERLOAD RELAY

FUSE- (XA) INDICATES RATING

SWITCH- UN-FUSED CUTOUT- (XAF) INDICATES FRAME SIZE

SWITCH- FUSED CUTOUT- (XA) INDICATES RATING

VARIABLE FREQUENCY DRIVE- (X) INDICATES MOTOR CONTROLLED

XY

XY

XAFXAT

XAFXA

XAXP

T / XXXXXXKVAXXXV, XPH, XW PRIXXXY / XXXV, XPH, XW SECY

XA

PANELBOARD- TOP DESIGNATES PANELBOARD TYPE- BOTTOM DESIGNATES PANELBOARD ID

GENERATOR

SHUNT TRIP

RESISTOR

STRESS CONE

POTHEAD

ONE LINE DIAGRAM

MOTOR STARTER AND DISCONNECTCOMBINATION- MAGNETIC- (X) INDICATES TYPE: (2S2W) 2 SPEED, 2 WINDING (2S1W) 2 SPEED, 1 WINDING (CB) CIRCUIT BREAKER (F) FUSED DISCONNECT SWITCH (FVNR) FULL VOLTAGE NON-REVERSING (FVR) FULL VOLTAGE REVERSING (NEMA1) NEMA STARTER SIZE (RV) REDUCED VOLTAGE STARTER- (Y) INDICATES MOTOR CONTROLLED

MOTOR STARTER- MAGNETIC- (X) INDICATES TYPE: (2S2W) 2 SPEED, 2 WINDING (2S1W) 2 SPEED, 1 WINDING (FVNR) FULL VOLTAGE NON-REVERSING (FVR) FULL VOLTAGE REVERSING (NEMA1) NEMA STARTER SIZE (RV) REDUCED VOLTAGE STARTER- (Y) INDICATES MOTOR CONTROLLED

CIRCUIT BREAKER- (XA) INDICATES TRIP SIZE- (XP) INDICATES NUMBER OF POLES

TRANSFORMER- CURRENT- ((X)) INDICATES QUANTITY- (X-XA) INDICATES RATIO

TRANSFORMER- POTENTIAL- ((X)) INDICATES QUANTITY

TRANSFORMER- DRY TYPE, UOI- (XXX) INDICATES EQUIPMENT IDENTIFICATION- (XXXKVA) INDICATES RATING- (XXXV, XPH, XW PRI) INDICATES PRIMARY VOLTAGE, PHASE, AND WIRES- (XXXY / XXXV, XPH, XW SEC) INDICATES SECONDARY VOLTAGE, PHASE, AND WIRES

GROUND FAULT CIRCUITINTERRUPTER- PERSONAL PROTECTION

LIGHTNING ARRESTER WITHGROUND CONNECTION TOPROTECT ALL PHASES

GROUND CONNECTIONTO SYSTEM AND / OREQUIPMENT

CONTACT- NORMALLY CLOSED- (TO) INDICATES TIMED OPENING OPTION

CONTACT- NORMALLY OPEN- (TC) INDICATES TIMED CLOSING OPTION

DISCONNECT SWITCH- CIRCUIT BREAKER- (XAF) INDICATES FRAME SIZE- (XAT) INDICATES TRIP SIZE- SIZE AS INDICATED ON DRAWINGS

DISCONNECT SWITCH- FUSED- (XAF) INDICATES FRAME SIZE- (XA) INDICATES FUSE RATING- SIZE AS INDICATED ON DRAWINGS

DISCONNECT SWITCH- NON-FUSED- (XA) INDICATES RATING- SIZE AS INDICATED ON DRAWINGS

AUTO-TRANSFER SWITCHVOICE/DATA OUTLET- (X) INDICATES QUANTITY:(D) INDICATES DATA(V) INDICATES VOICE(B) INDICATES BLANK

UNDERGROUND FIBER OPTIC CABLE

OVERHEAD FIBER OPTIC CABLE

UNDERGROUND TELECOMMUNICATIONSCABLE OR DUCTBANK

OVERHEAD TELECOMMUNICATIONSCABLE

VOICE/DATA

VOICE/DATA OUTLET WITH JACK- WALL MOUNTED PHONE- 48" AFF

ANTENNA SYSTEMMASTER OUTLET (MATV)

ANTENNA SYSTEMOUTLET (CATV)

VOICE/DATA OUTLET- CEILING MOUNTED- (X) INDICATES QUANTITY:(D) INDICATES DATA(V) INDICATES VOICE(B) INDICATES BLANK

TV

TV

FO

T

M

W

CX X

LIGHTNING PROTECTION / GROUNDINGCABLE

GROUNDING

GROUND CONDUCTORSPARE COIL

EXOTHERMIC CONNECTION- WELD OR BOLTED AS INDICATED ON DRAWINGS

GROUND CONNECTIONTO STRUCTURAL STEEL

GROUND TESTSTATION

GROUND ROD

VFD

F

CB

ST

GFCI

G

X

X

Y X

X

X

X

X

X

X

X

X

X

X

EQUIPMENT REFERENCE- TOP DESIGNATES EQUIPMENT TYPE: (LP) LIGHTING PANEL (MDP) MAIN DISTRIBUTION PANEL (MSB) MAIN SWITCHBOARD PANEL (PP) POWER PANEL (RC) RELAY CABINET (RP) RECEPTACLE PANEL (LCP) LIGHTING CONTROL PANEL (T) TRANSFORMER- BOTTOM DESIGNATES EQUIPMENT ID

ELECTRICAL BOX- FLOOR MOUNTED- POKE THRU- OUTLET TYPES REQUIRED AT EACH BOX AS INDICATED ON DRAWINGS

WIRING DEVICES

MOTOR STARTERS AND DISCONNECTS

EQUIPMENT AND PANELBOARDS

JUNCTION BOXCEILING MOUNTED

MOTOR STARTER- MANUAL

MOTOR STARTER- MAGNETIC- (X) INDICATES MOTOR STARTER CONTROLLED (SEE SCHEDULE)

METER

GENERATOR

SURFACE OR SUSPENDED MOUNTEDCONDUIT

UNDERGROUND OR UNDERFLOORCONDUIT OR DUCTBANK

UNDERGROUND POWER CONDUCTOROR DUCTBANK

OVERHEAD POWER CONDUCTOR

RACEWAYS AND BOXES

CURRENT TRANSFORMERCABINET

DISCONNECT SWITCH- FUSED- (X) INDICATES MOTOR FED BY SWITCH

DISCONNECT SWITCH- (X) INDICATES MOTOR FED BY SWITCH

DUPLEX RECEPTACLE- MOUNTED 1'-6" AFF, UOI- (X) INDICATES CIRCUIT NUMBER (PANEL BOUNDARY AS INDICATED ON DRAWINGS)- (Y) INDICATES TYPE:

(D)DEDICATED (DD)DOUBLE DUPLEX

(GFCI) GROUND FAULT CIRCUIT INTERRUPTING(WP) WEATHERPROOF

(WR) WEATHER RESISTANT

COMBINATION MOTOR STARTER- (X) INDICATES MOTOR STARTER CONTROLLED (SEE SCHEDULE)

TRANSFORMER- PAD MOUNTED

TRANSFORMER- MOUNTED ON 4" CONCRETE PAD, UOI- (X) INDICATES MOUNTING TYPE: (W) WALL (S) SURFACE BRANCH PANELBOARD

- SURFACE MOUNTED- (SEE SCHEDULE)

BRANCH PANELBOARD- RECESSED MOUNTED- (SEE SCHEDULE)

MOTOR CONNECTION- (X) INDICATES MOTOR IDENTIFICATION (SEE SCHEDULE)

SPECIAL PURPOSE OUTLET- (X) INDICATES DEVICE IDENTIFICATION (SEE SCHEDULE)

MULTI-OUTLET RACEWAYASSEMBLY- WALL MOUNTED 1'-6" AFF, UOI- (X) INDICATES TYPE (SEE SPECIFICATION)

ELECTRICAL BOX- FLOOR MOUNTED- FLUSH- OUTLET TYPES REQUIRED AT EACH BOX AS INDICATED ON DRAWINGS

DUPLEX RECEPTACLE- MOUNTED FLUSH IN CEILING- (X) INDICATES CIRCUIT NUMBER (PANEL BOUNDARY AS INDICATED ON DRAWINGS)

DUPLEX RECEPTACLE- MOUNTED FLUSH IN COUNTERTOP- (X) INDICATES CIRCUIT NUMBER (PANEL BOUNDARY AS INDICATED ON DRAWINGS)

DUPLEX RECEPTACLE- TOP HALF SWITCHED- MOUNTED 1'-6" AFF, UOI- (X) INDICATES CIRCUIT NUMBER (PANEL BOUNDARY AS INDICATED ON DRAWINGS)

DUPLEX RECEPTACLEMOUNTED 6" ABOVECOUNTER BACKSPLASH, UOI- (X) INDICATES CIRCUIT NUMBER (PANEL BOUNDARY AS INDICATED ON DRAWINGS)

DISTRIBUTION PANELBOARD- (SEE ONE-LINE)

XX/X

HAND DRYER CONNECTION

- PROVIDE JUNCTION BOX FOR

WIRING TERMINATIONS AND 30A

MOTOR RATED SWITCH FOR

DISCONNECT

CTG

M

F

X

F

P

E

E

M

C

S

J

EXIT LIGHT FIXTURE- END MOUNTED- SHADING INDICATES FACE(S)- ARROW(S) AND FACE(S) AS INDICATED ON DRAWINGS

X

X

X

X

X

X

ta

ra

oa

dal

ca

A-1b

X a

X

UNDERGROUND LIGHTING CONDUCTOR

OVERHEAD LIGHTING CONDUCTOR

LIGHTING CONTROL

LIGHTING FIXTURE DESIGNATIONS

LIGHTING FIXTURES

STRIP OR UNDER CABINET

DOUBLE HEAD SPOT OR FLOOD

SINGLE HEAD SPOT OR FLOOD

IN-GROUND OR IN-FLOOR MOUNTED

POST TOP MOUNTED

POLE MOUNTED WITH ARM

WALL MOUNTED

RECESS MOUNTED

SURFACE MOUNTED

EMERGENCY BATTERY REMOTE- DUAL LIGHTING HEADS

EMERGENCY BATTERY REMOTE- SINGLE LIGHTING HEAD

EMERGENCY BATTERY UNIT- DUAL LIGHTING HEADS

RECESS MOUNTED ACCENT- CHEVRON INDICATES DIRECTION OF ILLUMINATION

SURFACE MOUNTED ACCENT

- CHEVRON INDICATES

DIRECTION OF ILLUMINATION

PHOTOCELL- (X) INDICATES TYPE (SEE SCHEDULE)

TIME CLOCK- (X) INDICATES TYPE (SEE SCHEDULE)

CONTACTOR- (X) INDICATES TYPE (SEE SCHEDULE)

DAYLIGHT SENSOR- (X) INDICATES TYPE (SEE SCHEDULE)

TIME CLOCK DESIGNATION (SEE SCHEDULE)TIME CLOCK CONTROLLED

RELAY DESIGNATION

CONTROLLING CIRCUIT OR

PORTION OF CIRCUIT

LOW VOLTAGE RELAY

CONTROLLED VIA RELAY CABINET

SPECIFIC DEVICE DESIGNATION CONTROLLING CIRCUIT OR PORTION OF CIRCUITOCCUPANCY SENSOR CONTROLLED

DIMMER CHANNELCABINET DESIGNATIONCONTROLLED VIA ELECTRONIC DIMMING SYSTEM

CONTACTOR DESIGNATION

(SEE SCHEDULE)

CONTROLLED VIA CONTACTOR

OCCUPANCY SENSOR- CEILING MOUNTED- (X) INDICATES TYPE (SEE SCHEDULE)- CHEVRON(S) INDICATE SENSING DIRECTION(S)

OCCUPANCY SENSOR- WALL MOUNTED 3'-8" AFF, UOI- (X) INDICATES TYPE (SEE SCHEDULE)

WALL BOX DIMMER STATION- (3) INDICATES 3-WAY DIMMER

SWITCH- MOMENTARY CONTACT- MOUNTED 3'-8" AFF, UOI- (X) INDICATES SYSTEM DESIGNATION

SWITCH- MOUNTED 3'-8" AFF, UOI- (a) INDICATES SWITCH DESIGNATION- SINGLE POLE, UOI- (X) INDICATES SWITCH TYPE: (2) TWO POLE (3) THREE WAY (4) FOUR WAY (DLS) DUAL LEVEL SWITCH (K) KEY OPERATED (P) WITH PILOT LIGHT (T) TIMER

LIGHTING TRACK- LENGTH AS INDICATED ON DRAWINGS- NUMBER AND DIRECTION OF FIXTURES AS INDICATED ON DRAWINGS AND / OR SCHEDULE

EXIT LIGHT FIXTURE- CEILING MOUNTED- SHADING INDICATES FACE(S)- ARROW(S) AND FACE(S) AS INDICATED ON DRAWINGS

PARTIAL SHADING INDICATES FIXTUREPARTIALLY WIRED TO EMERGENCYOR NIGHT LIGHTING CIRCUIT

SHADING INDICATES FIXTUREFULLY WIRED TO EMERGENCYOR NIGHT LIGHTING CIRCUIT

TYPICALAT EACHFIXTURELOCATION

LIGHT FIXTURE DESIGNATION- (A) INDICATES FIXTURE TYPE (SEE SCHEDULE)- (1) INDICATES CIRCUIT NUMBER (PANEL BOUNDS AS INDICATED ON DRAWINGS)- (b) INDICATES CONTROL DESIGNATION (IF NOT INDICATED, CONTROLLED VIA SWITCH AT ROOM ENTRY)

SUSPENDED, PENDENT, CHAIN,STEM, OR CABLE HUNG

D

OS

L

L

DS

OS

C

T

PC

1P2P3P4P1P,1W1P,2W2P,2W2P,3W3P,2W3P,3W3P,4W4P,4WAACAFAFFAFGAICALASATARCHATSA / VBBFBFFBFGBLDGCCATCATVCBCKTCLGCOCTCUCLDDCDDDR∆DISCDWDWGEECEMTETRERLERLDEWCEXFAFLAFOFPCGCGFCIGFPEGNDGRCHHHPHVACHZJBKVA

KVARKWLPLSLTGLVMCMCAMCCMDPMISCMHMLOMTDMTGMTSMWN / AMVNCNECNICNO#NTSPPBPCPHPNLPPPRPRIPVCRECREFRSCSCSECSNSPSSSTSTPSUSPSWSWBDTTCTCITELE / DATATELTELECOMTPTYPUGUTPUOIVWWAWPXFMRXRXVYZAM

- KILOVOLT AMPERE REACTIVE - KILOWATT - LIGHTING PANEL - LIMIT SWITCH - LIGHTING - LOW VOLTAGE - MECHANICAL CONTRACTOR - MINIMUM CIRCUIT AMPS - MOTOR CONTROL CENTER - MAIN DISTRIBUTION PANEL - MISCELLANEOUS - MANHOLE - MAIN LUGS ONLY - MOUNTED - MOUNTING - MANUAL TRANSFER SWITCH - MICROWAVE - NOT APPLICABLE - MEDIUM VOLTAGE - NORMALLY CLOSED - NATIONAL ELECTRIC CODE - NOT IN CONTRACT - NORMALLY OPEN - NUMBER - NOT TO SCALE - POLE - PULL BOX - PLUMBING SYSTEM CONTRACTOR - PHASE - PANEL OR PANELBOARD - POWER PANEL - PAIR - PRIMARY - POLYVINYL CHLORIDE - RECESSED - REFRIGERATOR - RIGID STEEL CONDUIT - SECURITY CONTRACTOR - SECONDARY - SOLID NEUTRAL - SPARE - STAINLESS STEEL - SHUNT TRIP - SHIELDED TWISTED PAIR - SUSPENDED - SWITCH - SWITCHBOARD - TAMPER RESISTANT SAFETY RECEPTACLE - TELEPHONE CABINET - TELECOMMUNICATIONS CABLING INSTALLER - TELEPHONE / DATA - TELEPHONE - TELECOMMUNICATIONS - TWISTED PAIR - TYPICAL - UNDERGROUND - UNSHIELDED TWISTED PAIR - UNLESS OTHERWISE INDICATED - VOLT - WATT - WASHER - WEATHERPROOF - TRANSFORMER - XRAY - XRAY VIEWER - WYE - ZONE ADAPTER MODULE

- ONE POLE - TWO POLE - THREE POLE - FOUR POLE - ONE POLE, ONE WIRE - ONE POLE, TWO WIRE - TWO POLE, TWO WIRE - TWO POLE, THREE WIRE - THREE POLE, TWO WIRE - THREE POLE, THREE WIRE - THREE POLE, FOUR WIRE - FOUR POLE, FOUR WIRE - AMPERE - ALTERNATING CURRENT - AMPERE FRAME - ABOVE FINISHED FLOOR - ABOVE FINISHED GRADE - AMPERE INTERRUPTING CAPACITY - ALUMINUM - AMP SWITCH - AMP TRIP - ARCHITECT - AUTOMATIC TRANSFER SWITCH - AUDIO VISUAL - PEDESTAL MOUNTED ON BENCH TOP - BELOW FLOOR - BELOW FINISHED FLOOR - BELOW FINISHED GRADE - BUILDING - CONDUIT - CATALOG - CABLE TELEVISION - CIRCUIT BREAKER - CIRCUIT - CEILING MOUNTED - COPIER - CURRENT TRANSFORMER - COPPER - CENTERLINE - DEDICATED DEVICE - DIRECT CURRENT - DOUBLE DUPLEX - DRYER - DELTA - DISCONNECT - DISHWASHER - DRAWING - EMERGENCY - ELECTRICAL CONTRACTOR - ELECTRIC METALLIC TUBING - EXISTING TO REMAIN - EXISTING TO BE RELOCATED - RELOCATED EQUIPMENT'S NEW LOCATION - ELECTRIC WATER COOLER - EXISTING - FIRE ALARM - FULL LOAD AMPS - FIBER OPTIC - FIRE PROTECTION CONTRACTOR - GENERAL CONTRACTOR - GROUND FAULT INTERRUPTER - GROUND FAULT PROTECTION EQUIPMENT - GROUND - GALVANIZED RIGID CONDUIT - HANDHOLE - HORSEPOWER - HEATING, VENTILATING, AND AIR CONDITIONING - HERTZ (CYCLE) PER SECOND - JUNCTION BOX - KILOVOLT AMPERE

ELECTRICAL SYMBOLS AND ABBREVIATIONS

CONDUCTORS AND WIRING

GENERAL SYMBOLS

ELECTRICAL ABBREVIATIONS

NOTE: NOT ALL SYMBOLS AND ABBREVIATIONS INDICATED HERE ARE USED IN DRAWINGS AND MAY

NOT APPLY TO CURRENT PROJECT. ADDITIONAL SYMBOLS MAY BE INDICATED ON DRAWINGS.

NO

TE

: A

T T

HE

TIM

E O

F B

UIL

DIN

G P

ER

MIT

AP

PL

ICA

TIO

N, T

HE

AR

CH

ITE

CT

HA

S N

OT

BE

EN

SO

EM

PL

OY

ED

TO

FU

RN

ISH

C

ON

ST

RU

CT

ION

OB

SE

RV

AT

ION

OR

CO

NS

TR

UC

TIO

N A

DM

INIS

TR

AT

ION

SE

RV

ICE

S. T

HE

AR

CH

ITE

CT

HA

S N

O

KN

OW

LE

DG

E O

F T

HE

ST

AR

T O

F C

ON

ST

RU

CT

ION

NO

R D

OE

S H

E H

AV

E K

NO

WL

ED

GE

OF

AN

Y O

TH

ER

RE

GIS

TE

RE

D

AR

CH

ITE

CT

BE

ING

SO

EM

PL

OY

ED

TO

FU

RN

ISH

CO

NS

TR

UC

TIO

N O

BS

ER

VA

TIO

N O

R C

ON

ST

RU

CT

ION

AD

MIN

IST

RA

TIO

N

SE

RV

ICE

S.

CHECKED BY:

DRAWN BY:

DATE:

SHEET

P.3

52.3

78.4

400

F.3

52.3

77.5

378

1628

NW

6T

H S

TR

EE

TG

AIN

ES

VIL

LE F

L 32

609

AR

CH

ITE

CT

S &

PL

AN

NE

RS

FL

CE

RT

IFIC

AT

E

SV

M

SK

INN

ER

VIG

NO

LA

McL

EA

N,

INC

.

FO

R

ALL

RE

PO

RT

S,

PLA

NS

, S

PE

CIF

ICA

TIO

NS

, C

OM

PU

TE

R F

ILE

S,

FIE

LD D

AT

A,

NO

TE

S &

OT

HE

R D

OC

UM

EN

TS

& IN

ST

RU

ME

NT

S P

RE

PA

RE

D B

Y T

HE

DE

SIG

N P

RO

FE

SS

ION

AL

AS

INS

TR

UM

EN

TS

OF

SE

RV

ICE

SH

ALL

RE

MA

IN T

HE

PR

OP

ER

TY

OF

TH

E D

ES

IGN

PR

OF

ES

SIO

NA

L. T

HE

DE

SIG

N P

RO

FE

SS

ION

AL

SH

ALL

RE

TA

IN A

LL C

OM

MO

N L

AW

, S

TA

TU

TO

RY

& O

TH

ER

RE

SE

RV

ED

RIG

HT

S,

INC

LUD

ING

TH

E C

OP

YR

IGH

T T

HE

RE

TO

. U

SE

OF

TH

ES

E D

OC

UM

EN

TS

FO

R A

NY

PU

RP

OS

E O

RP

RO

JEC

T O

TH

ER

TH

AN

TH

E P

RO

JEC

T W

HIC

H I

S S

UB

JEC

T O

F T

HE

AG

RE

EM

EN

T IS

UN

LAW

FU

L.

AA

3478

PR

OJE

CT

LO

CA

TIO

N:

Ale

xand

er H

. Par

rish

8732

2

AHP

2300 Maitland Center ParkwaySuite 210

Maitland, FL 32751-7411407 / 659 6500

407 / 659 0609 faxwww.graef-usa.com

CERT # 4270

2300 Maitland Center ParkwaySuite 210

Maitland, FL 32751-7411407 / 659 6500

407 / 659 0609 faxwww.graef-usa.com

CERT # 4270

1/2

8/2

020 3

:35:5

7 P

MC

:\U

sers

\2044\D

ocum

ents

\20154111_E

20_2044.r

vt

10/28/2019

E0.1ELECTRICAL

SYMBOLS ANDABBREVIATIONS

CO

OP

ER

HA

LL R

EN

OV

AT

ION

AT

CA

MP

BL

AN

DIN

G J

OIN

TT

RA

ININ

G C

EN

TE

R (

CB

JT

C)

CLA

Y C

OU

NT

YS

TA

RK

E,

FL

DE

SIG

N P

HA

SE

: B

ID D

OC

UM

EN

TS

AEV

01318

RE

VIS

ION

S

J

R

D

J

A

B

WINDOW A.C. UNIT

WINDOW A.C. UNIT

WINDOW A.C. UNIT

WINDOW A.C. UNIT

WINDOW A.C. UNIT

C

11

1 1

11

1

DE-STRAT FAN

1

1

1

1

1

2

2

F

33

DEMO

3

33

3

D

ROOF FAN

ROOF A.C. UNIT

GENERAL NOTES

1. ALL ELECTRICAL EQUIPMENT SHOWN ON THIS DEMOLITION PLAN IS "EXISTING TO BE REMOVED" UNLESS NOTED OTHERWISE. IN ADDITION TO REMOVING DEVICES, REMOVE ALL CONDUIT AND WIRING BACK TO THEIR SOURCE. REFER TO THE SPECIFICATIONS FOR ADDITIONAL ELECTRICAL DEMOLITION REQUIREMENTS.

2. EXISTING CONDITIONS SHOWN ON THIS DRAWING ARE TAKEN FROM ORIGINAL DRAWINGS AND FIELD INVESTIGATION. ALL EXISTING CONDITIONS MUST BE VERIFIED PRIOR TO BID. FIELD CONDITIONS SHALL GOVERN.

3. THE DEMOLITION PLAN IS NOT INCLUSIVE OF ALL ELECTRICAL DEVICES WITHIN THE PROJECT AREA. IT IS INTENDED TO PROVIDE THE CONTRACTOR WITH A GENERAL KNOWLEDGE OF THE EXISTING CONDITIONS WITHIN THE PROJECT AREA. ANY DISCREPANCIES OR CONDITIONS NOT SHOWN ON THIS PLAN SHALL BE BROUGHT TO THE ATTENTION OF THE ENGINEER. THE CONTRACTOR IS RESPONSIBLE FOR ALL REQUIRED DEMOLITION WHETHER SHOWN ON THE PLANS OR NOT.

4. ALL ITEMS REMOVED UNDER THIS PROJECT SHALL BE DISPOSED OF OR TURNED OVER TO THE OWNER AT THE OWNER'S DISCRETION.

5. THIS CONTRACTOR SHALL PROVIDE ELECTRICAL FOR PHASING WORK AS REQUIRED OR DIRECTED BY THE ARCHITECT, REFER TO ARCHITECTURAL PHASING PLAN. TEMPORARY ELECTRICAL SERVICES (POWER, LIGHTING, FIRE ALARM, ETC.) SHALL BE PROVIDED WHEN NEW WORK AFFECTS SERVICES NEEDING TO REMAIN ACTIVE. IF FIRE ALARM SYSTEM CANNOT BE MAINTAINED IN THE CONSTRUCTION AREA, A FIRE WATCH SHALL BE PROVIDED.

6. "ETR" DENOTES EXISTING ELECTRICAL DEVICE TO REMAIN.

7. IN GENERAL, DASHED WALLS ON THIS PLAN INDICATE EXISTING WALLS BEING DEMOLISHED. DO NOT RELY SOLEY ON ELECTRICAL DRAWINGS TO DETERMINE EXTEND OF GENERAL CONSTRUCTION DEMOLITION. REFER TO ARCHITECTURAL DEMOLITION PLANS FOR THE EXACT EXTENT OF GENERAL CONSTRUCTION DEMOLITION REQUIRED BY THIS CONTRACT.

8. REFER TO DEMOLITION DRAWINGS OF OTHER TRADES. WHERE MOTORS, CONTROL PANELS, AND OTHER LOADS THAT HAVE AN ELECTRICAL CONNECTION ARE BEING REMOVED, INCLUDE THE DISCONNECTION AND REMOVAL OF ASSOCIATED ELECTRICAL FEEDS, CIRCUITS, AND LOOSE CONTROL EQUIPMENT IN THIS CONTRACT.

1 EXISTING DUPLEX OUTLET LOCATION TO BE REVISED. SEE NOTE #1 SHEET E1.1 FOR ADDITIONAL INFORMATION.

REMOVE EXISTING FIXTURE. RELOCATE CIRCUIT AS NEEDED FOR NEW LIGHTING FIXTURE WITHIN THIS SAME ROOM AS SHOWN ON SHEET E2.1.

REMOVE EXISTING FIXTURE AND ASSOCIATED WIRING BACK TO SOURCE.

2

KEYED NOTES THIS SHEET

3

NO

TE

: A

T T

HE

TIM

E O

F B

UIL

DIN

G P

ER

MIT

AP

PL

ICA

TIO

N, T

HE

AR

CH

ITE

CT

HA

S N

OT

BE

EN

SO

EM

PL

OY

ED

TO

FU

RN

ISH

C

ON

ST

RU

CT

ION

OB

SE

RV

AT

ION

OR

CO

NS

TR

UC

TIO

N A

DM

INIS

TR

AT

ION

SE

RV

ICE

S. T

HE

AR

CH

ITE

CT

HA

S N

O

KN

OW

LE

DG

E O

F T

HE

ST

AR

T O

F C

ON

ST

RU

CT

ION

NO

R D

OE

S H

E H

AV

E K

NO

WL

ED

GE

OF

AN

Y O

TH

ER

RE

GIS

TE

RE

D

AR

CH

ITE

CT

BE

ING

SO

EM

PL

OY

ED

TO

FU

RN

ISH

CO

NS

TR

UC

TIO

N O

BS

ER

VA

TIO

N O

R C

ON

ST

RU

CT

ION

AD

MIN

IST

RA

TIO

N

SE

RV

ICE

S.

CHECKED BY:

DRAWN BY:

DATE:

SHEET

P.3

52.3

78.4

400

F.3

52.3

77.5

378

1628

NW

6T

H S

TR

EE

TG

AIN

ES

VIL

LE F

L 32

609

AR

CH

ITE

CT

S &

PL

AN

NE

RS

FL

CE

RT

IFIC

AT

E

SV

M

SK

INN

ER

VIG

NO

LA

McL

EA

N,

INC

.

FO

R

ALL

RE

PO

RT

S,

PLA

NS

, S

PE

CIF

ICA

TIO

NS

, C

OM

PU

TE

R F

ILE

S,

FIE

LD D

AT

A,

NO

TE

S &

OT

HE

R D

OC

UM

EN

TS

& IN

ST

RU

ME

NT

S P

RE

PA

RE

D B

Y T

HE

DE

SIG

N P

RO

FE

SS

ION

AL

AS

INS

TR

UM

EN

TS

OF

SE

RV

ICE

SH

ALL

RE

MA

IN T

HE

PR

OP

ER

TY

OF

TH

E D

ES

IGN

PR

OF

ES

SIO

NA

L. T

HE

DE

SIG

N P

RO

FE

SS

ION

AL

SH

ALL

RE

TA

IN A

LL C

OM

MO

N L

AW

, S

TA

TU

TO

RY

& O

TH

ER

RE

SE

RV

ED

RIG

HT

S,

INC

LUD

ING

TH

E C

OP

YR

IGH

T T

HE

RE

TO

. U

SE

OF

TH

ES

E D

OC

UM

EN

TS

FO

R A

NY

PU

RP

OS

E O

RP

RO

JEC

T O

TH

ER

TH

AN

TH

E P

RO

JEC

T W

HIC

H I

S S

UB

JEC

T O

F T

HE

AG

RE

EM

EN

T IS

UN

LAW

FU

L.

AA

3478

PR

OJE

CT

LO

CA

TIO

N:

Ale

xand

er H

. Par

rish

8732

2

AHP

2300 Maitland Center ParkwaySuite 210

Maitland, FL 32751-7411407 / 659 6500

407 / 659 0609 faxwww.graef-usa.com

CERT # 4270

2300 Maitland Center ParkwaySuite 210

Maitland, FL 32751-7411407 / 659 6500

407 / 659 0609 faxwww.graef-usa.com

CERT # 4270

1/2

8/2

020 3

:35:5

7 P

MC

:\U

sers

\2044\D

ocum

ents

\20154111_E

20_2044.r

vt

10/28/2019

E0.2.1ELECTRICALDEMOLITION

CO

OP

ER

HA

LL R

EN

OV

AT

ION

AT

CA

MP

BL

AN

DIN

G J

OIN

TT

RA

ININ

G C

EN

TE

R (

CB

JT

C)

CLA

Y C

OU

NT

YS

TA

RK

E,

FL

DE

SIG

N P

HA

SE

: B

ID D

OC

UM

EN

TS

AEV

01318

1/8" = 1'-0"1FIRST FLOOR DEMOLITION PLAN

1/8" = 1'-0"2SECOND FLOOR DEMOLITION PLAN

TRUE

TRUE

RE

VIS

ION

S

DN

38' - 6"

17' -

0"

3' - 0"

4' -

6"

H

H

H

H

H

J

J

J

1A

REACH-IN COOLER

AC-1 AC-2

AC-7 OAU-1

OACU-1CU-3

VRCU-1

AC-6

AC-5

AC-8

VRCU-2

CU-1AHU-1

ALL CIRCUITS IN THIS AREA SHALL BE SERVED FROM PANEL 1/A UNLESS NOTED OTHERWISE.

ALL CIRCUITS IN THIS AREA SHALL BE SERVED FROM PANEL 1/B UNLESS NOTED OTHERWISE.

ALL CIRCUITS IN THIS AREA SHALL BE SERVED FROM PANEL 1/B UNLESS NOTED OTHERWISE.

ALL CIRCUITS IN THIS AREA SHALL BE SERVED FROM PANEL 1/A UNLESS NOTED OTHERWISE.

VESTIBULE

102

STORAGE

114

ENTRY

101

SERVICE TOILET

115

MECH

111

BUFFET AREA

108

FIRE RISER/MECH

106

TERRACE

107

PHONE RM

116

STAIR HALL

104

SCREEN PORCH

117

WOMENS

110

CATERING KITCHEN

113

MENS

109

SUPPLY / MECH

112

2

1B

1

1

1

W1

W

1

111

1 1

1

GFIWP

11

1

MDP

ETR

7:9

13:15:17

19

21:23

31:33:35 37:39:41 32:34

29292929

36:38

24

26 24 26

20

18

16

224

16 18 16 18

10:12

2

25

2

6:8

5

22

2

4

44

4

4

2117

14:16

18:20:22

9

11:13

GFI

WP

1:3 5:7 1721 15

15

17211521171521

17

15

33

365

2

4

2

2

2

22

2

3

6 2#12 & 1#12GNDIN 3/4"C

3#8 & 1#10GNDIN 3/4"C

2#12 & 1#12GNDIN 3/4"C

2#12 & 1#12GNDIN 3/4"C

2#12 & 1#12GNDIN 3/4"C

2#12 & 1#12GNDIN 3/4"C

2#12 & 1#12GNDIN 3/4"C

2#12 & 1#12GNDIN 3/4"C

3#10 & 1#10GNDIN 3/4"C

3#12 & 1#12 GNDIN 3/4"C

3#10 & 1#10GNDIN 3/4"C

3#8 & 1#10GNDIN 3/4"C

2#12 & 1#12GNDIN 3/4"C

8

6

10

12

14

7

7

7

7

7

8

24

3531 GFI

WP

GFI

WP

33

GFI

WP

9

3 3 3

FREEZER REF.

5

5

11

GFI

WP

48" AFF

GFI

48" AFF

GFI

48" AFF

GFI

48" AFF

GFI

2

4GFI

4

GFI

4GFI

11

GFI

WP

5

5

5

48" AFF

GFI

40:42

2#12 & 1#12GNDIN 3/4"C

VRCU-3

46:48

2

3#12 & 1#12 GNDIN 3/4"C

AC-9

3

48" AFF

GFI

48" AFF

GFI

48" AFF

GFI

48" AFF

GFI

48" AFF

GFI

48" AFF

GFI

48" AFF

GFI

48" AFF

GFI

48" AFF

GFI

GFIGFI GFI GFI

GENERAL NOTES

1. THE ELECTRICAL INSTALLATION SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA BUILDING CODE 2017 AND THE NATIONAL ELECTRIC CODE 2014.

2. ALL GROUNDING ELECTRODE SYSTEMS SHALL BE INTERCONNECTED PER NEC ARTICLE 250.52.

3. ALL WIRING SHALL BE IN CONDUIT. MINIMUM CONDUIT SIZE IS 3/4" UNLESS OTHERWISE NOTED. MC CABLE IS ALLOWED, HOWEVER, ALL HOMERUNS SHALL BE IN CONDUIT. WHERE MC CABLE IS PROVIDED, THE CONDUIT SIZE IS IGNORED. ENT IS NOT PERMITTED. PVC IS ACCEPTABLE WHERE ALLOWED BY CODE. CONTRACTOR MAY USE EMT, GRS OR IMC AS ALLOWED BY CODE.

4. WIRE SIZE SHALL BE MINIMUM #12 AWG, THWN SOLID COPPER UNLESS OTHERWISE NOTED. PROVIDE GROUND WIRE IN ALL CIRCUITS.

5. VOLTAGE DROP IN ACCORDANCE WITH FLORIDA BUILDING CODE 6TH EDITION (2017) ENERGY CONSERVATION CODE CHAPTER 4, SECTION C405.6.3 HAS TAKEN IN ACCOUNT FOR THIS PROJECT. INCREASE WIRE SIZE TO COMPENSATE FOR VOLTAGE DROP WHERE TOTAL LENGTH OF ANY BRANCH EXCEEDS 100 FEET.

6. MULTIPLE BRANCH CIRCUITS SHALL NOT HAVE A SHARED NEUTRAL CONDUCTOR.

1 LOCATION OF EXISTING DUPLEX OUTLET. EC SHALL PROVIDE NEW DEVICE, FACEPLATE, AND BRANCH WIRING. EC MAY RE-USE EXISTING BACKBOX AND CONDUIT WHERE POSSIBLE AND PRACTICAL.

PROVIDE A NEW 240V, 30A, 2P, FUSED DISCONNECT IN A NEMA 1 ENCLOSURE. FUSES SHALL BE RATED FOR CLASS RK5, CURRENT LIMITING AND HAVE DUAL ELEMENT TIME DELAY. COORDINATE FUSE SIZE WITH MECHANICAL EQUIPMENT PRIOR TO INSTALLATION.

PROVIDE A NEW 240V, 30A, 2P, FUSED DISCONNECT IN A NEMA 3R ENCLOSURE. FUSES SHALL BE RATED FOR CLASS RK5, CURRENT LIMITING AND HAVE DUAL ELEMENT TIME DELAY. COORDINATE FUSE SIZE WITH MECHANICAL EQUIPMENT PRIOR TO INSTALLATION.

PROVIDE A NEW 240V, 30A, 3P, FUSED DISCONNECT IN A NEMA 1 ENCLOSURE. FUSES SHALL BE RATED FOR CLASS RK5, CURRENT LIMITING AND HAVE DUAL ELEMENT TIME DELAY. COORDINATE FUSE SIZE WITH MECHANICAL EQUIPMENT PRIOR TO INSTALLATION.

PROVIDE A NEW 240V, 30A, 3P, FUSED DISCONNECT IN A NEMA 3R ENCLOSURE. FUSES SHALL BE RATED FOR CLASS RK5, CURRENT LIMITING AND HAVE DUAL ELEMENT TIME DELAY. COORDINATE FUSE SIZE WITH MECHANICAL EQUIPMENT PRIOR TO INSTALLATION.

PROVIDE A NEW 240V, 60A, 3P, FUSED DISCONNECT IN A NEMA 3R ENCLOSURE. FUSES SHALL BE RATED FOR CLASS RK5, CURRENT LIMITING AND HAVE DUAL ELEMENT TIME DELAY. COORDINATE FUSE SIZE WITH MECHANICAL EQUIPMENT PRIOR TO INSTALLATION.

PROVIDE A 30A 120V SINGLE POLE MOTOR-RATED SWITCH IN LOCKABLE NEMA 1 ENCLOSURE WALL MOUNTED ABOVE THE HAND DRYER AT 6'-6" AFF (TO MIDDLE OF ENCLOSURE) TO ACT AS A DISCONNECTING MEANS. CONCEAL ALL CONDUIT WITHIN THE WALL. PROVIDE NAMEPLATE WITH LABEL "HAND DRYER DISCONNECT".

PROVIDE CONNECTION TO FIREPLACE STARTER AND SWITCH. COORDINATE WITH MANUFACTURER'S INSTALLATION INSTRUCTIONS.

LOCATION OF EXISTING JUNCTION BOX. EC SHALL PROVIDE DUPLEX RECEPTACLLE, FACEPLATE, AND BRANCH WIRING. EC MAY RE-USE EXISTING BACKBOX AND CONDUIT WHERE POSSIBLE AND PRACTICAL.

KEYED NOTES THIS SHEET

2

3

4

5

6

7. WORKING CLEARANCES SHALL BE MAINTAINED FOR ALL ELECTRICAL EQUIPMENT IN ACCORDANCE WITH NEC ARTICLE 110.26.

8. WHERE PENETRATING A FIRE RATED WALL ASSEMBLY FOR WIRING, UTILIZE A UL LISTED FIRE-RATED ASSEMBLY, SIZED FOR THE CONDUIT MAKING THE PENETRATION, RATED FOR THE TYPE OF MATERIAL PENETRATING THE ASSEMBLY AND THE MATERIAL BEING PENETRATED, AND POSSESSING THE FIRE RATING OF THE ORIGINAL WALL ASSEMBLY. PENETRATION SHALL BE BY USG OR APPROVED OTHER.

9. REFER TO HVAC WIRING DIAGRAMS AND SCHEDULES FOR CIRCUIT REQUIREMENTS OF HVAC EQUIPMENT.

10. REFER TO ARCHITECTURAL DRAWINGS FOR ROOM NAMES AND NUMBERS.

11. ALL NEW CONDUIT PROVIDED SHALL BE CONCEALED IN WALLS, IN SLABS, IN NEW ARCHITECTURAL FEATURES, OR SURFACE MOUNTED IN THE CRAWL SPACE BENEATH THE FIRST FLOOR SO PEOPLE USING BUILDING CAN NOT SEE ANY CONDUITS.

12. ALL RECEPTACLES LOCATED IN CATERING KITCHEN #113 SHALL BE GFCI TYPE OR GFCI PROJECTED.

7

8

9

NO

TE

: A

T T

HE

TIM

E O

F B

UIL

DIN

G P

ER

MIT

AP

PL

ICA

TIO

N, T

HE

AR

CH

ITE

CT

HA

S N

OT

BE

EN

SO

EM

PL

OY

ED

TO

FU

RN

ISH

C

ON

ST

RU

CT

ION

OB

SE

RV

AT

ION

OR

CO

NS

TR

UC

TIO

N A

DM

INIS

TR

AT

ION

SE

RV

ICE

S. T

HE

AR

CH

ITE

CT

HA

S N

O

KN

OW

LE

DG

E O

F T

HE

ST

AR

T O

F C

ON

ST

RU

CT

ION

NO

R D

OE

S H

E H

AV

E K

NO

WL

ED

GE

OF

AN

Y O

TH

ER

RE

GIS

TE

RE

D

AR

CH

ITE

CT

BE

ING

SO

EM

PL

OY

ED

TO

FU

RN

ISH

CO

NS

TR

UC

TIO

N O

BS

ER

VA

TIO

N O

R C

ON

ST

RU

CT

ION

AD

MIN

IST

RA

TIO

N

SE

RV

ICE

S.

CHECKED BY:

DRAWN BY:

DATE:

SHEET

P.3

52.3

78.4

400

F.3

52.3

77.5

378

1628

NW

6T

H S

TR

EE

TG

AIN

ES

VIL

LE F

L 32

609

AR

CH

ITE

CT

S &

PL

AN

NE

RS

FL

CE

RT

IFIC

AT

E

SV

M

SK

INN

ER

VIG

NO

LA

McL

EA

N,

INC

.

FO

R

ALL

RE

PO

RT

S,

PLA

NS

, S

PE

CIF

ICA

TIO

NS

, C

OM

PU

TE

R F

ILE

S,

FIE

LD D

AT

A,

NO

TE

S &

OT

HE

R D

OC

UM

EN

TS

& IN

ST

RU

ME

NT

S P

RE

PA

RE

D B

Y T

HE

DE

SIG

N P

RO

FE

SS

ION

AL

AS

INS

TR

UM

EN

TS

OF

SE

RV

ICE

SH

ALL

RE

MA

IN T

HE

PR

OP

ER

TY

OF

TH

E D

ES

IGN

PR

OF

ES

SIO

NA

L. T

HE

DE

SIG

N P

RO

FE

SS

ION

AL

SH

ALL

RE

TA

IN A

LL C

OM

MO

N L

AW

, S

TA

TU

TO

RY

& O

TH

ER

RE

SE

RV

ED

RIG

HT

S,

INC

LUD

ING

TH

E C

OP

YR

IGH

T T

HE

RE

TO

. U

SE

OF

TH

ES

E D

OC

UM

EN

TS

FO

R A

NY

PU

RP

OS

E O

RP

RO

JEC

T O

TH

ER

TH

AN

TH

E P

RO

JEC

T W

HIC

H I

S S

UB

JEC

T O

F T

HE

AG

RE

EM

EN

T IS

UN

LAW

FU

L.

AA

3478

PR

OJE

CT

LO

CA

TIO

N:

Ale

xand

er H

. Par

rish

8732

2

AHP

2300 Maitland Center ParkwaySuite 210

Maitland, FL 32751-7411407 / 659 6500

407 / 659 0609 faxwww.graef-usa.com

CERT # 4270

2300 Maitland Center ParkwaySuite 210

Maitland, FL 32751-7411407 / 659 6500

407 / 659 0609 faxwww.graef-usa.com

CERT # 4270

1/2

8/2

020 3

:35:5

8 P

MC

:\U

sers

\2044\D

ocum

ents

\20154111_E

20_2044.r

vt

10/28/2019

E1.1PROPOSED POWER

& SYSTEMS PLANFIRST FLOOR

CO

OP

ER

HA

LL R

EN

OV

AT

ION

AT

CA

MP

BL

AN

DIN

G J

OIN

TT

RA

ININ

G C

EN

TE

R (

CB

JT

C)

CLA

Y C

OU

NT

YS

TA

RK

E,

FL

DE

SIG

N P

HA

SE

: B

ID D

OC

UM

EN

TS

AEV

01318

TRUE

1/4" = 1'-0"1FIRST FLOOR POWER AND SYSTEMS PLAN

RE

VIS

ION

S

35' -

6"

6' - 0"

13' -

0"

26' - 6"

4' -

0"

11' - 0"

H

2A

AHU-3

ATTIC/CLO

206

HVAC CLO

202

HVAC

205

CLO

207

STAIR LANDING

201

DIXIE ROOM

203

UNISEX RESTROOM

204

OPEN TO BELOW

1

1

1

4

4

4

4

2

2

2

15:17

2

3

3

3

1

5

11

1

5

91

5

3

2#12 & 1#12GNDIN 3/4"C

7 3

GFI

GFI

UC REF

GFI

GFI

UC ICE MAKER

GFI

GENERAL NOTES

1. THE ELECTRICAL INSTALLATION SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA BUILDING CODE 2017 AND THE NATIONAL ELECTRIC CODE 2014.

2. ALL GROUNDING ELECTRODE SYSTEMS SHALL BE INTERCONNECTED PER NEC ARTICLE 250.52.

3. ALL WIRING SHALL BE IN CONDUIT. MINIMUM CONDUIT SIZE IS 3/4" UNLESS OTHERWISE NOTED. MC CABLE IS ALLOWED, HOWEVER, ALL HOMERUNS SHALL BE IN CONDUIT. WHERE MC CABLE IS PROVIDED, THE CONDUIT SIZE IS IGNORED. ENT IS NOT PERMITTED. PVC IS ACCEPTABLE WHERE ALLOWED BY CODE. CONTRACTOR MAY USE EMT, GRS OR IMC AS ALLOWED BY CODE.

4. WIRE SIZE SHALL BE MINIMUM #12 AWG, THWN SOLID COPPER UNLESS OTHERWISE NOTED. PROVIDE GROUND WIRE IN ALL CIRCUITS.

5. VOLTAGE DROP IN ACCORDANCE WITH FLORIDA BUILDING CODE 6TH EDITION (2017) ENERGY CONSERVATION CODE CHAPTER 4, SECTION C405.6.3 HAS TAKEN IN ACCOUNT FOR THIS PROJECT. INCREASE WIRE SIZE TO COMPENSATE FOR VOLTAGE DROP WHERE TOTAL LENGTH OF ANY BRANCH EXCEEDS 100 FEET.

6. MULTIPLE BRANCH CIRCUITS SHALL NOT HAVE A SHARED NEUTRAL CONDUCTOR.

7. WORKING CLEARANCES SHALL BE MAINTAINED FOR ALL ELECTRICAL EQUIPMENT IN ACCORDANCE WITH NEC ARTICLE 110.26.

8. WHERE PENETRATING A FIRE RATED WALL ASSEMBLY FOR WIRING, UTILIZE A UL LISTED FIRE-RATED ASSEMBLY, SIZED FOR THE CONDUIT MAKING THE PENETRATION, RATED FOR THE TYPE OF MATERIAL PENETRATING THE ASSEMBLY AND THE MATERIAL BEING PENETRATED, AND POSSESSING THE FIRE RATING OF THE ORIGINAL WALL ASSEMBLY. PENETRATION SHALL BE BY USG OR APPROVED OTHER.

9. REFER TO HVAC WIRING DIAGRAMS AND SCHEDULES FOR CIRCUIT REQUIREMENTS OF HVAC EQUIPMENT.

10. REFER TO ARCHITECTURAL DRAWINGS FOR ROOM NAMES AND NUMBERS.

11. ALL NEW CONDUIT PROVIDED SHALL BE CONCEALED IN WALLS, IN SLABS, IN NEW ARCHITECTURAL FEATURES, OR SURFACE MOUNTED IN THE CRAWL SPACE BENEATH THE FIRST FLOOR SO PEOPLE USING BUILDING CAN NOT SEE ANY CONDUITS.

12. ALL CIRCUITS ON THIS PLAN SHALL BE SERVED FROM PANEL '2A' UNLESS NOTED OTHERWISE.

1 LOCATION OF EXISTING DUPLEX OUTLET. EC SHALL PROVIDE NEW DEVICE, FACEPLATE, AND BRANCH WIRING. EC MAY RE-USE EXISTING BACKBOX AND CONDUIT WHERE POSSIBLE AND PRACTICAL.

PROVIDE A NEW 240V, 30A, 2P, FUSED DISCONNECT IN A NEMA 1 ENCLOSURE. FUSES SHALL BE RATED FOR CLASS RK5, CURRENT LIMITING AND HAVE DUAL ELEMENT TIME DELAY. COORDINATE FUSE SIZE WITH MECHANICAL EQUIPMENT PRIOR TO INSTALLATION.

PROVIDE A 30A 120V SINGLE POLE MOTOR-RATED SWITCH IN LOCKABLE NEMA 1 ENCLOSURE WALL MOUNTED ABOVE THE HAND DRYER AT 6'-6" AFF (TO MIDDLE OF ENCLOSURE) TO ACT AS A DISCONNECTING MEANS. CONCEAL ALL CONDUIT WITHIN THE WALL. PROVIDE NAMEPLATE WITH LABEL "HAND DRYER DISCONNECT".

KEYED NOTES THIS SHEET

2

3

NO

TE

: A

T T

HE

TIM

E O

F B

UIL

DIN

G P

ER

MIT

AP

PL

ICA

TIO

N, T

HE

AR

CH

ITE

CT

HA

S N

OT

BE

EN

SO

EM

PL

OY

ED

TO

FU

RN

ISH

C

ON

ST

RU

CT

ION

OB

SE

RV

AT

ION

OR

CO

NS

TR

UC

TIO

N A

DM

INIS

TR

AT

ION

SE

RV

ICE

S. T

HE

AR

CH

ITE

CT

HA

S N

O

KN

OW

LE

DG

E O

F T

HE

ST

AR

T O

F C

ON

ST

RU

CT

ION

NO

R D

OE

S H

E H

AV

E K

NO

WL

ED

GE

OF

AN

Y O

TH

ER

RE

GIS

TE

RE

D

AR

CH

ITE

CT

BE

ING

SO

EM

PL

OY

ED

TO

FU

RN

ISH

CO

NS

TR

UC

TIO

N O

BS

ER

VA

TIO

N O

R C

ON

ST

RU

CT

ION

AD

MIN

IST

RA

TIO

N

SE

RV

ICE

S.

CHECKED BY:

DRAWN BY:

DATE:

SHEET

P.3

52.3

78.4

400

F.3

52.3

77.5

378

1628

NW

6T

H S

TR

EE

TG

AIN

ES

VIL

LE F

L 32

609

AR

CH

ITE

CT

S &

PL

AN

NE

RS

FL

CE

RT

IFIC

AT

E

SV

M

SK

INN

ER

VIG

NO

LA

McL

EA

N,

INC

.

FO

R

ALL

RE

PO

RT

S,

PLA

NS

, S

PE

CIF

ICA

TIO

NS

, C

OM

PU

TE

R F

ILE

S,

FIE

LD D

AT

A,

NO

TE

S &

OT

HE

R D

OC

UM

EN

TS

& IN

ST

RU

ME

NT

S P

RE

PA

RE

D B

Y T

HE

DE

SIG

N P

RO

FE

SS

ION

AL

AS

INS

TR

UM

EN

TS

OF

SE

RV

ICE

SH

ALL

RE

MA

IN T

HE

PR

OP

ER

TY

OF

TH

E D

ES

IGN

PR

OF

ES

SIO

NA

L. T

HE

DE

SIG

N P

RO

FE

SS

ION

AL

SH

ALL

RE

TA

IN A

LL C

OM

MO

N L

AW

, S

TA

TU

TO

RY

& O

TH

ER

RE

SE

RV

ED

RIG

HT

S,

INC

LUD

ING

TH

E C

OP

YR

IGH

T T

HE

RE

TO

. U

SE

OF

TH

ES

E D

OC

UM

EN

TS

FO

R A

NY

PU

RP

OS

E O

RP

RO

JEC

T O

TH

ER

TH

AN

TH

E P

RO

JEC

T W

HIC

H I

S S

UB

JEC

T O

F T

HE

AG

RE

EM

EN

T IS

UN

LAW

FU

L.

AA

3478

PR

OJE

CT

LO

CA

TIO

N:

Ale

xand

er H

. Par

rish

8732

2

AHP

2300 Maitland Center ParkwaySuite 210

Maitland, FL 32751-7411407 / 659 6500

407 / 659 0609 faxwww.graef-usa.com

CERT # 4270

2300 Maitland Center ParkwaySuite 210

Maitland, FL 32751-7411407 / 659 6500

407 / 659 0609 faxwww.graef-usa.com

CERT # 4270

1/2

8/2

020 3

:35:5

8 P

MC

:\U

sers

\2044\D

ocum

ents

\20154111_E

20_2044.r

vt

10/28/2019

E1.2PROPOSED POWER

& SYSTEMS PLANSECOND FLOOR

CO

OP

ER

HA

LL R

EN

OV

AT

ION

AT

CA

MP

BL

AN

DIN

G J

OIN

TT

RA

ININ

G C

EN

TE

R (

CB

JT

C)

CLA

Y C

OU

NT

YS

TA

RK

E,

FL

DE

SIG

N P

HA

SE

: B

ID D

OC

UM

EN

TS

AEV

01318

SCALE: 1/4" = 1'-0"E1.2

SECOND FLOOR POWER AND SYSTEMS PLAN2

TRUE

RE

VIS

ION

S

OS

OSOS

OS

OS

OS

OS

OS

OS

OS

OS OS

OS

JJ

OS

JJJJ

J J

J

J

E-2 E-2 E-2 E-2 E-2E-2

LIGHT1B-30,b

FAN 1B-32,g

LIGHT1B-32,c

FAN 1B-30,g

E-2

M

X

X

X

X X

H

H

H H

H

H

H

H H

H

H

H

H H

H

H

H

H

RELOCATE POWER CONNECTION INTO CENTER OF ROOM.

H H

X1A

EBU1

EBU1

EBU1

X

1B

EBU1

FAN 1B-32,g

EBU1

EBU1

P P

P P

P P

P

K

K

3a

ALL CIRCUITS IN THIS AREA SHALL BE SERVED FROM PANEL 1/A UNLESS NOTED OTHERWISE.

ALL CIRCUITS IN THIS AREA SHALL BE SERVED FROM PANEL 1/B UNLESS NOTED OTHERWISE.

ALL CIRCUITS IN THIS AREA SHALL BE SERVED FROM PANEL 1/B UNLESS NOTED OTHERWISE.

ALL CIRCUITS IN THIS AREA SHALL BE SERVED FROM PANEL 1/A UNLESS NOTED OTHERWISE.

VESTIBULE

102

STORAGE

114

ENTRY

101

SERVICE TOILET

115

MECH

111

BUFFET AREA

108

FIRE RISER/MECH

106

TERRACE

107

PHONE RM

116

STAIR HALL

104

ENTRY HALL

103

LOUNGE

105

SCREEN PORCH

117

WOMENS

110

CATERING KITCHEN

113

MENS

109

SUPPLY / MECH

112

OS

OS

D

OS

OS

FAN 1B-30,g

OS

Da

PP

PP

1A-28 1A-28

1A-28

1A-28 1A-28

1A-28

1A-281A-28PP

PP

PP

1A-30 1A-30 1A-30

1A-301A-301A-30

1A-30 1A-30 1A-30

1A-30

1A-301A-30

1A-30 1A-30

1A-301A-30

PP

PP 1B-29,b

1B-29

1B-291B-29,b

1B-29,b

C-11B-38

2A-12,a

L1B-29

1B-29

1A-28

1A-28

1A-28

1A-28

1A-30

1A-30

1A-30

1A-30

1B-29

1B-29

E-1

1B-29

LIGHT1B-32,c

Q 1B-36,f

LIGHT1B-30,b

1B-27 1B-27

1B-27,a1B-27,a1B-27,a

LIGHT1B-25,b

PP

PP

PP

PP

PP

1B-28,a

1B-32,c

1B-34,e

1B-30,b

1B-29,d

PP

PP

1B-25,b

1B-27,a

1A-28

1A-30

1A-30

1A-30

PP 1B-25,c

2

1

4

2

5

1

2

4

2

4

2

42

2

4

1

2

4

8

8

2

4

1

3

6

6

4

4

4

4

4

3

3

1

3

6

4

4

4

D

Db

c

LIGHT1B-25,b

LIGHT1B-25,b

LIGHT1B-25,b

1B-27,a1B-27,a1B-27,a

Q 1B-36,f Q 1B-36,f

1B-28,a

EBU1

Q 1B-34,e1B-34,e QQ 1B-34,eQ 1B-34,e

Da

Db Dc Dd

Db

2g

1B-38

1A-28

1B-29,d

E-1

1B-29,d

1B-291B-29

FAN1B-25,c

FAN1B-25,c

FAN1B-25,c

FAN1B-25,c

5

D-1

De

1B-28,a

PP 1B-36,f4

Df

9 9

10

11

P 1A-30

H

1B-29

PP

2 4

1B-381B-38

1212

1B-23,i

Di

1B-23,i1B-23,i1B-23,i

EBU2EBU21B-27

1B-27

101010

9

9

10 10

1010

11111111

1B-38

1B-38

1B-38

1B-381B-38

1B-38

1B-38

1B-38

PC

13

S

S

S

SS

S

S

S

1B-38

12

12

12

12

12

12

7

GENERAL NOTES

1. THE ELECTRICAL INSTALLATION SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA BUILDING CODE 2017 AND THE NATIONAL ELECTRIC CODE 2014.

2. ALL GROUNDING ELECTRODE SYSTEMS SHALL BE INTERCONNECTED PER NEC ARTICLE 250.52.

3. ALL WIRING SHALL BE IN CONDUIT. MINIMUM CONDUIT SIZE IS 3/4" UNLESS OTHERWISE NOTED. MC CABLE IS ALLOWED, HOWEVER, ALL HOMERUNS SHALL BE IN CONDUIT. WHERE MC CABLE IS PROVIDED, THE CONDUIT SIZE IS IGNORED. ENT IS NOT PERMITTED. PVC IS ACCEPTABLE WHERE ALLOWED BY CODE. CONTRACTOR MAY USE EMT, GRS OR IMC AS ALLOWED BY CODE.

4. WIRE SIZE SHALL BE MINIMUM #12 AWG, THWN SOLID COPPER UNLESS OTHERWISE NOTED. PROVIDE GROUND WIRE IN ALL CIRCUITS.

5. VOLTAGE DROP IN ACCORDANCE WITH FLORIDA BUILDING CODE 6TH EDITION (2017) ENERGY CONSERVATION CODE CHAPTER 4, SECTION C405.6.3 HAS TAKEN IN ACCOUNT FOR THIS PROJECT. INCREASE WIRE SIZE TO COMPENSATE FOR VOLTAGE DROP WHERE TOTAL LENGTH OF ANY BRANCH EXCEEDS 100 FEET.

6. MULTIPLE BRANCH CIRCUITS SHALL NOT HAVE A SHARED NEUTRAL CONDUCTOR.

7. WORKING CLEARANCES SHALL BE MAINTAINED FOR ALL ELECTRICAL EQUIPMENT IN ACCORDANCE WITH NEC ARTICLE 110.26.

8. WHERE PENETRATING A FIRE RATED WALL ASSEMBLY FOR WIRING, UTILIZE A UL LISTED FIRE-RATED ASSEMBLY, SIZED FOR THE CONDUIT MAKING THE PENETRATION, RATED FOR THE TYPE OF MATERIAL PENETRATING THE ASSEMBLY AND THE MATERIAL BEING PENETRATED, AND POSSESSING THE FIRE RATING OF THE ORIGINAL WALL ASSEMBLY. PENETRATION SHALL BE BY USG OR APPROVED OTHER.

9. REFER TO HVAC WIRING DIAGRAMS AND SCHEDULES FOR CIRCUIT REQUIREMENTS OF HVAC EQUIPMENT.

10. REFER TO ARCHITECTURAL DRAWINGS FOR ROOM NAMES AND NUMBERS.

11. ALL NEW CONDUIT PROVIDED SHALL BE CONCEALED IN WALLS, IN SLABS, IN NEW ARCHITECTURAL FEATURES, OR SURFACE MOUNTED IN THE CRAWL SPACE BENEATH THE FIRST FLOOR SO PEOPLE USING BUILDING CAN NOT SEE ANY CONDUITS.

12. POWER PACK LOCATIONS ARE ESTIMATED AND MAY BE RELOCATED AS REQUIRED TO MINIMIZE CIRCUIT LENGTH, AVOID OBSTRUCTIONS, REMAIN OUT OF SIGHT, ETC. PROVIDE THE QUANTITY OF POWER PACKS REQUIRED FOR THE NUMBER OF SWITCHING GROUPS SHOWN.

13. FOR ALL OCCUPANCY SENSORS ("OS") AND POWER PACKS ("PP"): REFER TO MANUFACTURER'S WIRING DIAGRAM.

14. FOR ALL POWER PACKS ("PP"): MOUNT POWER PACK ABOVE ACCESSIBLE CEILING OR ACCESSIBLE IN ADJACENT ROOM OUT OF SIGHT. PROVIDE TWO ADJACENT DEEP JUNCTION BOXES, ONE TO HOUSE THE POWER PACK, AND THE OTHER FOR THE WIRING TERMINATIONS.

1 WALL MOUNTED OCCUPANCY SENSOR SWITCH ("Sos") SHALL BE TYPE WSX PDT, 120/277VAC RATED, BY SENSOR SWITCH (ACUITY) OR APPROVED EQUAL BY OTHERS. OPERATING MODE SHALL BE AUTO-ON/AUTO-OFF. REFER TO MANUFACTURER'S WIRING DIAGRAM.

CEILING MOUNTED OCCUPANCY SENSOR ("OS") SHALL BE TYPE CM PDT 10, BY SENSOR SWITCH (ACUITY) OR APPROVED EQUAL. PHOTOCELL OPTION SHALL REMAIN DISABLED.

WALL MOUNTED OCCUPANCY SENSOR ("OS") SHALL BE TYPE WV PDT 16 KIT, BY SENSOR SWITCH (ACUITY) OR APPROVED EQUAL. PHOTOCELL OPTION SHALL REMAIN DISABLED.

DIMMING POWER PACK ("PP"), SHALL BE TYPE PP20, 120/277V RATED, BY SENSOR SWITCH (ACUITY) OR APPROVED EQUAL BY OTHERS.

WALL MOUNTED DIMMING ("D") SWITCH SHALL BE TYPE sPODMRD WH, BY SENSOR SWITCH (ACUITY) OR APPROVED EQUAL.

WALL MOUNTED DIMMING ("D") SWITCH SHALL BE TYPE ISD 400 ELV 120, BY SYNERGY LIGHTING CONTROLS (ACUITY) OR APPROVED EQUAL.

PROVIDE 2-POLE SWITCH FOR CONTROL OF SWITCH LEGS INDICATED.

CONNECT SWITCH LEG "a" CONTROLS TO SECOND FLOOR SWITCH LEG "a" POWER PACK CONTROLS FOR LIGHTS IN THE STAIRWELL AREA. SEE SHEET E2.2 FOR REFERENCE.

PROVIDE CONNECTION TO OWNER SELECTED FIXTURE. CIRCUIT AS INDICATED.

PROVIDE CEILING FAN/LIGHT COMBO SIMILAR TO HUNTER ROYAL OAK #54018 AND SCHOOLHOUSE GLOBE #22555. PROVIDE SEPARATE SWITCH LEGS FOR FAN AND LIGHT.

PROVIDE CONNECTION TO OWNER SELECTED LIGHTS. PROVIDE DIMMER SWITCH FOR CONTROL. PROVIDE SWITCH AS INDICATED.

PROVDE PROVIDE CONNECTION TO PHOTOCELL CONTROLLED CIRCUIT. REFER TO NOTE #13.

PROVIDE PHOTOCELL SWITCH MOUNTED TO GABLE FACIA BOARD IN LOCATION SHOWN. AIM PHOTOCELL TOWARD NORTHERN SKY WITH NO OBSTRUCTION FROM ROOFTOP. PROVIDE CONTROL CONTACT IN INTERIOR CEILING SPACE, IF NECESSARY.

KEYED NOTES THIS SHEET

2

3

4

5

6

7

8

9

10

11

12

13

NO

TE

: A

T T

HE

TIM

E O

F B

UIL

DIN

G P

ER

MIT

AP

PL

ICA

TIO

N, T

HE

AR

CH

ITE

CT

HA

S N

OT

BE

EN

SO

EM

PL

OY

ED

TO

FU

RN

ISH

C

ON

ST

RU

CT

ION

OB

SE

RV

AT

ION

OR

CO

NS

TR

UC

TIO

N A

DM

INIS

TR

AT

ION

SE

RV

ICE

S. T

HE

AR

CH

ITE

CT

HA

S N

O

KN

OW

LE

DG

E O

F T

HE

ST

AR

T O

F C

ON

ST

RU

CT

ION

NO

R D

OE

S H

E H

AV

E K

NO

WL

ED

GE

OF

AN

Y O

TH

ER

RE

GIS

TE

RE

D

AR

CH

ITE

CT

BE

ING

SO

EM

PL

OY

ED

TO

FU

RN

ISH

CO

NS

TR

UC

TIO

N O

BS

ER

VA

TIO

N O

R C

ON

ST

RU

CT

ION

AD

MIN

IST

RA

TIO

N

SE

RV

ICE

S.

CHECKED BY:

DRAWN BY:

DATE:

SHEET

P.3

52.3

78.4

400

F.3

52.3

77.5

378

1628

NW

6T

H S

TR

EE

TG

AIN

ES

VIL

LE F

L 32

609

AR

CH

ITE

CT

S &

PL

AN

NE

RS

FL

CE

RT

IFIC

AT

E

SV

M

SK

INN

ER

VIG

NO

LA

McL

EA

N,

INC

.

FO

R

ALL

RE

PO

RT

S,

PLA

NS

, S

PE

CIF

ICA

TIO

NS

, C

OM

PU

TE

R F

ILE

S,

FIE

LD D

AT

A,

NO

TE

S &

OT

HE

R D

OC

UM

EN

TS

& IN

ST

RU

ME

NT

S P

RE

PA

RE

D B

Y T

HE

DE

SIG

N P

RO

FE

SS

ION

AL

AS

INS

TR

UM

EN

TS

OF

SE

RV

ICE

SH

ALL

RE

MA

IN T

HE

PR

OP

ER

TY

OF

TH

E D

ES

IGN

PR

OF

ES

SIO

NA

L. T

HE

DE

SIG

N P

RO

FE

SS

ION

AL

SH

ALL

RE

TA

IN A

LL C

OM

MO

N L

AW

, S

TA

TU

TO

RY

& O

TH

ER

RE

SE

RV

ED

RIG

HT

S,

INC

LUD

ING

TH

E C

OP

YR

IGH

T T

HE

RE

TO

. U

SE

OF

TH

ES

E D

OC

UM

EN

TS

FO

R A

NY

PU

RP

OS

E O

RP

RO

JEC

T O

TH

ER

TH

AN

TH

E P

RO

JEC

T W

HIC

H I

S S

UB

JEC

T O

F T

HE

AG

RE

EM

EN

T IS

UN

LAW

FU

L.

AA

3478

PR

OJE

CT

LO

CA

TIO

N:

Ale

xand

er H

. Par

rish

8732

2

AHP

2300 Maitland Center ParkwaySuite 210

Maitland, FL 32751-7411407 / 659 6500

407 / 659 0609 faxwww.graef-usa.com

CERT # 4270

2300 Maitland Center ParkwaySuite 210

Maitland, FL 32751-7411407 / 659 6500

407 / 659 0609 faxwww.graef-usa.com

CERT # 4270

1/2

8/2

020 3

:35:5

9 P

MC

:\U

sers

\2044\D

ocum

ents

\20154111_E

20_2044.r

vt

10/28/2019

E2.1PROPOSED

LIGHTING PLANFIRST FLOOR

CO

OP

ER

HA

LL R

EN

OV

AT

ION

AT

CA

MP

BL

AN

DIN

G J

OIN

TT

RA

ININ

G C

EN

TE

R (

CB

JT

C)

CLA

Y C

OU

NT

YS

TA

RK

E,

FL

DE

SIG

N P

HA

SE

: B

ID D

OC

UM

EN

TS

AEV

01318

3/16" = 1'-0"1FIRST FLOOR LIGHTING PLAN

TRUE

RE

VIS

ION

S

OS

OS

OS

KL

L

L

C-1

E-4

X

EBU1

EBU1

EBU1

EBU1

OPEN TO BELOW

Db

X1

ATTIC/CLO

206HVAC CLO

202

HVAC

205

CLO

207

STAIR LANDING

201

DIXIE ROOM

203

UNISEX RESTROOM

204

OS

OS

OS

OS

OS

OS

2A-12

2A-12

2A-12

2A-12,a

PP 2A-12,a

2A-6

X

2A-6

2A-6

2A-6

2A-18

2A-18

2A-20

2A-18

2A-18

2A-18

2A

C-2

PPPP 2A-16,b 2A-16,c

PPPP 2A-10,d 2A-6,e

1

1

1

1

1

1

2

2

4

5

3

3

3

3

Dc

Dd

De

Da

2A-6,e

J

F

2A-12,a

F

E-2

2A-6,e

E-2

2A-6,e

E-2

2A-6,e

E-2

2A-10,d

J

2A-10,d

JJ2A-10,d

J

2A-10,d

J

2A-10,d

J

2A-10,d

J

2A-10,d

2A-10,d

2A-16,c

C-2

2A-16,c

B-1

2A-16,b

2

M

1B-38

6

GENERAL NOTES

1. THE ELECTRICAL INSTALLATION SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA BUILDING CODE 2017 AND THE NATIONAL ELECTRIC CODE 2014.

2. ALL GROUNDING ELECTRODE SYSTEMS SHALL BE INTERCONNECTED PER NEC ARTICLE 250.52.

3. ALL WIRING SHALL BE IN CONDUIT. MINIMUM CONDUIT SIZE IS 3/4" UNLESS OTHERWISE NOTED. MC CABLE IS ALLOWED, HOWEVER, ALL HOMERUNS SHALL BE IN CONDUIT. WHERE MC CABLE IS PROVIDED, THE CONDUIT SIZE IS IGNORED. ENT IS NOT PERMITTED. PVC IS ACCEPTABLE WHERE ALLOWED BY CODE. CONTRACTOR MAY USE EMT, GRS OR IMC AS ALLOWED BY CODE.

4. WIRE SIZE SHALL BE MINIMUM #12 AWG, THWN SOLID COPPER UNLESS OTHERWISE NOTED. PROVIDE GROUND WIRE IN ALL CIRCUITS.

5. VOLTAGE DROP IN ACCORDANCE WITH FLORIDA BUILDING CODE 6TH EDITION (2017) ENERGY CONSERVATION CODE CHAPTER 4, SECTION C405.6.3 HAS TAKEN IN ACCOUNT FOR THIS PROJECT. INCREASE WIRE SIZE TO COMPENSATE FOR VOLTAGE DROP WHERE TOTAL LENGTH OF ANY BRANCH EXCEEDS 100 FEET.

6. MULTIPLE BRANCH CIRCUITS SHALL NOT HAVE A SHARED NEUTRAL CONDUCTOR.

7. WORKING CLEARANCES SHALL BE MAINTAINED FOR ALL ELECTRICAL EQUIPMENT IN ACCORDANCE WITH NEC ARTICLE 110.26.

8. WHERE PENETRATING A FIRE RATED WALL ASSEMBLY FOR WIRING, UTILIZE A UL LISTED FIRE-RATED ASSEMBLY, SIZED FOR THE CONDUIT MAKING THE PENETRATION, RATED FOR THE TYPE OF MATERIAL PENETRATING THE ASSEMBLY AND THE MATERIAL BEING PENETRATED, AND POSSESSING THE FIRE RATING OF THE ORIGINAL WALL ASSEMBLY. PENETRATION SHALL BE BY USG OR APPROVED OTHER.

9. REFER TO HVAC WIRING DIAGRAMS AND SCHEDULES FOR CIRCUIT REQUIREMENTS OF HVAC EQUIPMENT.

10. REFER TO ARCHITECTURAL DRAWINGS FOR ROOM NAMES AND NUMBERS.

11. ALL NEW CONDUIT PROVIDED SHALL BE CONCEALED IN WALLS, IN SLABS, IN NEW ARCHITECTURAL FEATURES, OR SURFACE MOUNTED IN THE CRAWL SPACE BENEATH THE FIRST FLOOR SO PEOPLE USING BUILDING CAN NOT SEE ANY CONDUITS.

12. ALL CIRCUITS ON THIS PLAN SHALL BE SERVED FROM PANEL '2A' UNLESS NOTED OTHERWISE.

13. POWER PACK LOCATIONS ARE ESTIMATED AND MAY BE RELOCATED AS REQUIRED TO MINIMIZE CIRCUIT LENGTH, AVOID OBSTRUCTIONS, REMAIN OUT OF SIGHT, ETC. PROVIDE THE QUANTITY OF POWER PACKS REQUIRED FOR THE NUMBER OF SWITCHING GROUPS SHOWN.

14. FOR ALL LOW VOLTAGE ("LV") SWITCHES, OCCUPANCY SENSORS ("OS"), AND POWER PACKS ("PP"): REFER TO MANUFACTURER'S WIRING DIAGRAM. PROVIDE ALL CAT5e CABLE AND/OR 0-10V WIRING AS REQUIRED FOR A COMPLETE INSTALLATION.

15. FOR ALL POWER PACKS ("PP"): MOUNT POWER PACK ABOVE ACCESSIBLE CEILING OR ACCESSIBLE IN ADJACENT ROOM OUT OF SIGHT. PROVIDE TWO ADJACENT DEEP JUNCTION BOXES, ONE TO HOUSE THE POWER PACK, AND THE OTHER FOR THE WIRING TERMINATIONS.

1 WALL MOUNTED OCCUPANCY SENSOR SWITCH ("Sos") SHALL BE TYPE WSX PDT, 120/277VAC RATED, BY SENSOR SWITCH (ACUITY) OR APPROVED EQUAL BY OTHERS. OPERATING MODE SHALL BE AUTO-ON/AUTO-OFF. REFER TO MANUFACTURER'S WIRING DIAGRAM.

WALL MOUNTED OCCUPANCY SENSOR ("OS") SHALL BE TYPE WV PDT 16 KIT, BY SENSOR SWITCH (ACUITY) OR APPROVED EQUAL. PHOTOCELL OPTION SHALL REMAIN DISABLED.

DIMMING POWER PACK ("PP"), SHALL BE TYPE PP20, 120/277V RATED, BY SENSOR SWITCH (ACUITY) OR APPROVED EQUAL BY OTHERS.

WALL MOUNTED DIMMING ("D") SWITCH SHALL BE TYPE ISD 400 ELV 120, BY SYNERGY LIGHTING CONTROLS (ACUITY) OR APPROVED EQUAL.

CONNECT SWITCH LEG "a" CONTROLS TO FIRST FLOOR SWITCH LEG "a" LIGHT FIXTURE IN THE STAIRWELL AREA. SEE SHEET E2.1 FOR REFERENCE.

PROVDE PROVIDE CONNECTION TO PHOTOCELL CONTROLLED CIRCUIT. REFER TO NOTE #13 IN SHEET E2.1

KEYED NOTES THIS SHEET

2

3

4

5

6

NO

TE

: A

T T

HE

TIM

E O

F B

UIL

DIN

G P

ER

MIT

AP

PL

ICA

TIO

N, T

HE

AR

CH

ITE

CT

HA

S N

OT

BE

EN

SO

EM

PL

OY

ED

TO

FU

RN

ISH

C

ON

ST

RU

CT

ION

OB

SE

RV

AT

ION

OR

CO

NS

TR

UC

TIO

N A

DM

INIS

TR

AT

ION

SE

RV

ICE

S. T

HE

AR

CH

ITE

CT

HA

S N

O

KN

OW

LE

DG

E O

F T

HE

ST

AR

T O

F C

ON

ST

RU

CT

ION

NO

R D

OE

S H

E H

AV

E K

NO

WL

ED

GE

OF

AN

Y O

TH

ER

RE

GIS

TE

RE

D

AR

CH

ITE

CT

BE

ING

SO

EM

PL

OY

ED

TO

FU

RN

ISH

CO

NS

TR

UC

TIO

N O

BS

ER

VA

TIO

N O

R C

ON

ST

RU

CT

ION

AD

MIN

IST

RA

TIO

N

SE

RV

ICE

S.

CHECKED BY:

DRAWN BY:

DATE:

SHEET

P.3

52.3

78.4

400

F.3

52.3

77.5

378

1628

NW

6T

H S

TR

EE

TG

AIN

ES

VIL

LE F

L 32

609

AR

CH

ITE

CT

S &

PL

AN

NE

RS

FL

CE

RT

IFIC

AT

E

SV

M

SK

INN

ER

VIG

NO

LA

McL

EA

N,

INC

.

FO

R

ALL

RE

PO

RT

S,

PLA

NS

, S

PE

CIF

ICA

TIO

NS

, C

OM

PU

TE

R F

ILE

S,

FIE

LD D

AT

A,

NO

TE

S &

OT

HE

R D

OC

UM

EN

TS

& IN

ST

RU

ME

NT

S P

RE

PA

RE

D B

Y T

HE

DE

SIG

N P

RO

FE

SS

ION

AL

AS

INS

TR

UM

EN

TS

OF

SE

RV

ICE

SH

ALL

RE

MA

IN T

HE

PR

OP

ER

TY

OF

TH

E D

ES

IGN

PR

OF

ES

SIO

NA

L. T

HE

DE

SIG

N P

RO

FE

SS

ION

AL

SH

ALL

RE

TA

IN A

LL C

OM

MO

N L

AW

, S

TA

TU

TO

RY

& O

TH

ER

RE

SE

RV

ED

RIG

HT

S,

INC

LUD

ING

TH

E C

OP

YR

IGH

T T

HE

RE

TO

. U

SE

OF

TH

ES

E D

OC

UM

EN

TS

FO

R A

NY

PU

RP

OS

E O

RP

RO

JEC

T O

TH

ER

TH

AN

TH

E P

RO

JEC

T W

HIC

H I

S S

UB

JEC

T O

F T

HE

AG

RE

EM

EN

T IS

UN

LAW

FU

L.

AA

3478

PR

OJE

CT

LO

CA

TIO

N:

Ale

xand

er H

. Par

rish

8732

2

AHP

2300 Maitland Center ParkwaySuite 210

Maitland, FL 32751-7411407 / 659 6500

407 / 659 0609 faxwww.graef-usa.com

CERT # 4270

2300 Maitland Center ParkwaySuite 210

Maitland, FL 32751-7411407 / 659 6500

407 / 659 0609 faxwww.graef-usa.com

CERT # 4270

1/2

8/2

020 3

:36:0

0 P

MC

:\U

sers

\2044\D

ocum

ents

\20154111_E

20_2044.r

vt

10/28/2019

E2.2PROPOSED

LIGHTING PLANSECOND FLOOR

CO

OP

ER

HA

LL R

EN

OV

AT

ION

AT

CA

MP

BL

AN

DIN

G J

OIN

TT

RA

ININ

G C

EN

TE

R (

CB

JT

C)

CLA

Y C

OU

NT

YS

TA

RK

E,

FL

DE

SIG

N P

HA

SE

: B

ID D

OC

UM

EN

TS

AEV

01318

3/16" = 1'-0"1SECOND FLOOR LIGHTING PLAN

TRUE

RE

VIS

ION

S

4#3/0 & 1#6 GNDIN 2"C

4#3/0 & 1#6 GNDIN 2"C

4#3/0 & 1#6 GNDIN 2"C

800A3P

200A3P

150A3P

225A3P

200A3P

225A3P

200A3P

2A

MDP-1 (EXISTING PANEL)800A, 120/208V, 3 PH, 4WSIEMENS PANELMINIMUM AIC RATING = EXISTING

1B

200A3P

1AA B C D F

30A3P

25A3P

35A3P

30A3P

COPPER FEEDER SCHEDULE

GENERAL NOTES:

FEEDERAMPACITY

1.

2.

3.

2OO - 4G

(2) #3/0

(3) 600

(3) #400

(2) #600

(2) #500

(2) #350

(3) 4''(3) 3-1/2''12OO

(3) 3-1/2''(3) 3''1OOO

(2) 4''(2) 3-1/2''8OO

(2) 3-1/2''(2) 3''7OO

(2) 3''(2) 3''6OO

(2) 3''(2) 2-1/2''(2) #2505OO

(2) 2-1/2''(2) 2''(2) #4/045O

4OO

3-1/2''3''#3#50038O

3-1/2''3''#3#50035O

3''3''#4#3503OO

3''2-1/2''#4#25025O

2-1/2''2''#4#4/0225

2-1/2''2''#6#3/02OO

2''2''#6#2/0175

2''1-1/2''#6#1/O15O

2''1-1/2''#6#1125

1OO 1-1/4''1-1/4''#8#3

CONDUCTOR SIZE (kcmil)

GRD

CONDUIT SIZE

(4) 600 (4) 4''(4) 3-1/2''16OO

(5) 600 (5) 4''(5) 3-1/2''2OOO

#2 1-1/2''1-1/4''11O

#8 1''3/4''5O

#4 1-1/4''1-1/4''8O

7O 1-1/4'' 1-1/4''#4 #8

#8

#6

(2) 2-1/2''(2) 2''

#1O

(3) #3/0

(3) #2/0

(2) #1/0

(2) #1/0

(4) #4/0

(5) #250

(2) #3

(2) #2

(2) #2

(2) #1

PH AND N (3) AND (3G) (4) AND (4G)

FEEDER DESIGNATION

SYSTEM DESCRIPTION(3) 3PH, 3W(3G) 3PH, 3W + GRD(4) 3PH, 4W(4G) 3PH, 4W + GRD

CONDUCTOR AMPACITY(SEE FEEDER SCHEDULE)

THE ABOVE FEEDER SCHEDULE IS A SCHEDULE OF TYPICALFEEDERS AND SOME SIZES MAY NOT BE UTILIZED.

ALL CONDUCTOR AMPACITIES ARE BASED ON TABLE 31O-16 OFTHE NEC FOR COPPER CONDUCTOR TYPE THW/THWN.

FEEDER SIZES SHOWN ON THE RISER DIAGRAM INDICATE CIRCUITBREAKER AMPACITIES AND DO NOT ACCOUNT FOR VOLTAGE DROP.

LINE TYPE LEGEND

ITEMS SHOWN AS SOLID BLACK LINES ARE NEW

ITEMS SHOWN AS DASHED BLACK LINES ARE EXISTING TO REMAIN

ITEMS SHOWN AS LONG DASH SHORT DASH BLACK LINES ARE EQUIPMENT ENCLOSURES.

ITEMS SHOWN AS DASHDOTDOT BLACK LINES ARE EXISTING TO BE DEMOLISHED

EQUIPMENT DESIGNATIONNAMEPLATECOLOR: NORMAL =BLACK

LETTERINGSHALL BE 1/4"HIGH

LETTER (FILL)COLOR: NORMAL =WHITE

INDICATEVOLTAGE, # OFPHASES, # OFWIRES

ATTACHNAMEPLATE WITH(2) SCREWS

INDICATE WHEREEQUIPMENT ISFED FROM

PANEL XXXXXX / XXXV, XXXPH, XXXW

FED FROM XXX, BREAKER XXX

LIGHT FIXTURE SCHEDULENOTE: SEE SPECIFICATION SECTIONS FOR ADDITIONAL INFORMATION REGARDING FIXTURE AND INSTALLATION REQUIREMENTS. PROVIDE OPTIONS AND ACCESSORIES REFERENCED BY THE COLUMN TITLED "OPTIONS / ACCESSORIES". MANUFACTURES LISTED AS ACCEPTABLE SHALL MEET ALL REQUIREMENTS AND FEATURES INDICATED. ACCEPTABLE MANUFACTURERS MUST MEET THE PHOTOMETRIC PERFORMANCE OF THE LISTED UNIT.

ABBREVIATIONS: DW + DRYWALL P = PENDANT R = RECESS V = VARIES

ES = EXPOSED STRUCTURE PL = PLASTER S = SURFACE

LG = LAY-IN GRID PO = POLE W = WALL MOUNTED

DESLAMP DATA

DESCRIPTIONLIGHT FIXTURE

VOLTS MOUNTCEILING

TYPEFIXTURE DEPTH

OPTIONS / ACCESSORIES ACCEPTABLE MANUFACTURERS SEE NOTEQTY TYPE LAMP COLOR MANUFACTURER CATALOG SERIES

B-1 1100W A21

LED EQUIV.2700K FOUR LIGHT CHANDELIER DOWN PROGRESS LIGHTING NORTH PARK P4002 SERIES 120 P V - 1

C-1 2100W A21

LED EQUIV.2700K 12 1/2" SQUARE DECORATIVE PROGRESS LIGHTING NORTH PARK P3854 SERIES 120 S V - 1

C-2 2100W A21

LED EQUIV.2700K 15" SQUARE DECORATIVE PROGRESS LIGHTING NORTH PARK P3852 SERIES 120 S V - 1

D-1 1100W A21

LED EQUIV.2700K TWO LIGHT PEND. PROGRESS LIGHTING NORTH PARK P3597 SERIES 120 P V - 1

E-1 2100W A21

LED EQUIV.2700K SINGLE LIGHT DECORATIVE WALL MOUNT PROGRESS LIGHTING NORTH PARK P2733 SERIES 120 W V - 1

E-2 11100W A21

LED EQUIV.2700K TWO LIGHT DECORATIVE WALL MOUNT PROGRESS LIGHTING CLIFTON HEIGHTS P300159 SERIES 120 W V - 1

E-4 1100W A21

LED EQUIV.2700K FOUR LIGHT BATHROOM FIXTURE PROGRESS LIGHTING CLIFTON HEIGHTS P300161 SERIES 120 W V - 1

F 2100W A21

LED EQUIV.2700K STEM HUNG MINI PENDANT PROGRESS LIGHTING NORTH PARK P5135 SERIES 120 P V - 1

H 20 LED 3500K 2 X 4 LED TROFFER LITHONIA 2BLT4 40L ADP EZ1 LP835 120 R LG 3-3/4"WILLIAMS, METALUX

J 8LED 5300 LUMENS

2700K 6" LED DOWNLIGHT CREE LIGHTING KR6-60L-27K 120 R 7-1/2" DIMMING 2

K 3 LED 3500K LED WRAPAROUND LITHONIA BLW4 40L ADP GZ10 LP835 120 S V -WILLIAMS, METALUX

L 4 13WGU24 - KEYLESS LIGHT PASS & SEYMOUR 277 FL 120 S V -

M 2 EXTERIOR WALL MOUNT 120 W

P 8 LED 3500K 1' x 4' LED LIGHT PANEL TROFFER LITHONIA EPANL 1X4 3000LM 80CRI 35K MIN10 ZT MVOLT 120 R DW 4-1/4"

Q 7 LED LED STRIP LIGHT 120

EBU1 9 W/UNIT - EMERGENCY BATTERY UNIT LITHONIA ELM6L UVOLT LTP SDRT 120 S - - 1

X 10 W/UNIT - EXIT LIGHT LRP 1 GMR 120/277 EL N 120 S - - 3

LIGHT FIXTURE SCHEDULE NOTES:

1 CONFIRM FIXTURE FINISH WITH ARCHITECT.

2 REFLECTOR FINISH TO BE SELECED BY THE ARCHITECT.

3 PROVDIE GREEN LETTERS. HOUSING COLOR AND BACKGROUND FINISH SHALL BE SELECTED BY THE ARCHITECT.

EBU2 2 W/UNIT - EMERGENCY BATTERY UNIT LITHONIA ELM6L UVOLT LTP SDRT WPVS LRG W 120 S - - 1

X1 10 W/UNIT - EXIT LIGHT LRP 1 GMR LA 120/277 EL N 120 S - - 3

S 8 LED EXTERIOR LED STEP LIGHT 120 R2700K VISTA PROFESSIONAL 1501-AL-*-27-MV-ND 1, 4- -

4 FIELD COORDINATE FIXTURE SIZE WITH EXISTING FIXTURE HOLE AND PROVIDE SPACERS AS NEEDED. SEAL ANY GAPS.

NO

TE

: A

T T

HE

TIM

E O

F B

UIL

DIN

G P

ER

MIT

AP

PL

ICA

TIO

N, T

HE

AR

CH

ITE

CT

HA

S N

OT

BE

EN

SO

EM

PL

OY

ED

TO

FU

RN

ISH

C

ON

ST

RU

CT

ION

OB

SE

RV

AT

ION

OR

CO

NS

TR

UC

TIO

N A

DM

INIS

TR

AT

ION

SE

RV

ICE

S. T

HE

AR

CH

ITE

CT

HA

S N

O

KN

OW

LE

DG

E O

F T

HE

ST

AR

T O

F C

ON

ST

RU

CT

ION

NO

R D

OE

S H

E H

AV

E K

NO

WL

ED

GE

OF

AN

Y O

TH

ER

RE

GIS

TE

RE

D

AR

CH

ITE

CT

BE

ING

SO

EM

PL

OY

ED

TO

FU

RN

ISH

CO

NS

TR

UC

TIO

N O

BS

ER

VA

TIO

N O

R C

ON

ST

RU

CT

ION

AD

MIN

IST

RA

TIO

N

SE

RV

ICE

S.

CHECKED BY:

DRAWN BY:

DATE:

SHEET

P.3

52.3

78.4

400

F.3

52.3

77.5

378

1628

NW

6T

H S

TR

EE

TG

AIN

ES

VIL

LE F

L 32

609

AR

CH

ITE

CT

S &

PL

AN

NE

RS

FL

CE

RT

IFIC

AT

E

SV

M

SK

INN

ER

VIG

NO

LA

McL

EA

N,

INC

.

FO

R

ALL

RE

PO

RT

S,

PLA

NS

, S

PE

CIF

ICA

TIO

NS

, C

OM

PU

TE

R F

ILE

S,

FIE

LD D

AT

A,

NO

TE

S &

OT

HE

R D

OC

UM

EN

TS

& IN

ST

RU

ME

NT

S P

RE

PA

RE

D B

Y T

HE

DE

SIG

N P

RO

FE

SS

ION

AL

AS

INS

TR

UM

EN

TS

OF

SE

RV

ICE

SH

ALL

RE

MA

IN T

HE

PR

OP

ER

TY

OF

TH

E D

ES

IGN

PR

OF

ES

SIO

NA

L. T

HE

DE

SIG

N P

RO

FE

SS

ION

AL

SH

ALL

RE

TA

IN A

LL C

OM

MO

N L

AW

, S

TA

TU

TO

RY

& O

TH

ER

RE

SE

RV

ED

RIG

HT

S,

INC

LUD

ING

TH

E C

OP

YR

IGH

T T

HE

RE

TO

. U

SE

OF

TH

ES

E D

OC

UM

EN

TS

FO

R A

NY

PU

RP

OS

E O

RP

RO

JEC

T O

TH

ER

TH

AN

TH

E P

RO

JEC

T W

HIC

H I

S S

UB

JEC

T O

F T

HE

AG

RE

EM

EN

T IS

UN

LAW

FU

L.

AA

3478

PR

OJE

CT

LO

CA

TIO

N:

Ale

xand

er H

. Par

rish

8732

2

AHP

2300 Maitland Center ParkwaySuite 210

Maitland, FL 32751-7411407 / 659 6500

407 / 659 0609 faxwww.graef-usa.com

CERT # 4270

2300 Maitland Center ParkwaySuite 210

Maitland, FL 32751-7411407 / 659 6500

407 / 659 0609 faxwww.graef-usa.com

CERT # 4270

1/2

8/2

020 3

:36:0

0 P

MC

:\U

sers

\2044\D

ocum

ents

\20154111_E

20_2044.r

vt

10/28/2019

E3.1ELEC. ONE-LINE

DIAG., DETAILS, &LTG. FIXT. SCHED.

CO

OP

ER

HA

LL R

EN

OV

AT

ION

AT

CA

MP

BL

AN

DIN

G J

OIN

TT

RA

ININ

G C

EN

TE

R (

CB

JT

C)

CLA

Y C

OU

NT

YS

TA

RK

E,

FL

DE

SIG

N P

HA

SE

: B

ID D

OC

UM

EN

TS

AEV

01318

SCALE: NTSE3.1

ONE-LINE DIAGRAM1

SCALE: NTSE3.1

PANEL NAMEPLATE2

RE

VIS

ION

S

NO

TE

: A

T T

HE

TIM

E O

F B

UIL

DIN

G P

ER

MIT

AP

PL

ICA

TIO

N, T

HE

AR

CH

ITE

CT

HA

S N

OT

BE

EN

SO

EM

PL

OY

ED

TO

FU

RN

ISH

C

ON

ST

RU

CT

ION

OB

SE

RV

AT

ION

OR

CO

NS

TR

UC

TIO

N A

DM

INIS

TR

AT

ION

SE

RV

ICE

S. T

HE

AR

CH

ITE

CT

HA

S N

O

KN

OW

LE

DG

E O

F T

HE

ST

AR

T O

F C

ON

ST

RU

CT

ION

NO

R D

OE

S H

E H

AV

E K

NO

WL

ED

GE

OF

AN

Y O

TH

ER

RE

GIS

TE

RE

D

AR

CH

ITE

CT

BE

ING

SO

EM

PL

OY

ED

TO

FU

RN

ISH

CO

NS

TR

UC

TIO

N O

BS

ER

VA

TIO

N O

R C

ON

ST

RU

CT

ION

AD

MIN

IST

RA

TIO

N

SE

RV

ICE

S.

CHECKED BY:

DRAWN BY:

DATE:

SHEET

P.3

52.3

78.4

400

F.3

52.3

77.5

378

1628

NW

6T

H S

TR

EE

TG

AIN

ES

VIL

LE F

L 32

609

AR

CH

ITE

CT

S &

PL

AN

NE

RS

FL

CE

RT

IFIC

AT

E

SV

M

SK

INN

ER

VIG

NO

LA

McL

EA

N,

INC

.

FO

R

ALL

RE

PO

RT

S,

PLA

NS

, S

PE

CIF

ICA

TIO

NS

, C

OM

PU

TE

R F

ILE

S,

FIE

LD D

AT

A,

NO

TE

S &

OT

HE

R D

OC

UM

EN

TS

& IN

ST

RU

ME

NT

S P

RE

PA

RE

D B

Y T

HE

DE

SIG

N P

RO

FE

SS

ION

AL

AS

INS

TR

UM

EN

TS

OF

SE

RV

ICE

SH

ALL

RE

MA

IN T

HE

PR

OP

ER

TY

OF

TH

E D

ES

IGN

PR

OF

ES

SIO

NA

L. T

HE

DE

SIG

N P

RO

FE

SS

ION

AL

SH

ALL

RE

TA

IN A

LL C

OM

MO

N L

AW

, S

TA

TU

TO

RY

& O

TH

ER

RE

SE

RV

ED

RIG

HT

S,

INC

LUD

ING

TH

E C

OP

YR

IGH

T T

HE

RE

TO

. U

SE

OF

TH

ES

E D

OC

UM

EN

TS

FO

R A

NY

PU

RP

OS

E O

RP

RO

JEC

T O

TH

ER

TH

AN

TH

E P

RO

JEC

T W

HIC

H I

S S

UB

JEC

T O

F T

HE

AG

RE

EM

EN

T IS

UN

LAW

FU

L.

AA

3478

PR

OJE

CT

LO

CA

TIO

N:

Ale

xand

er H

. Par

rish

8732

2

AHP

2300 Maitland Center ParkwaySuite 210

Maitland, FL 32751-7411407 / 659 6500

407 / 659 0609 faxwww.graef-usa.com

CERT # 4270

2300 Maitland Center ParkwaySuite 210

Maitland, FL 32751-7411407 / 659 6500

407 / 659 0609 faxwww.graef-usa.com

CERT # 4270

1/2

8/2

020 3

:36:0

0 P

MC

:\U

sers

\2044\D

ocum

ents

\20154111_E

20_2044.r

vt

10/28/2019

E4.1ELECTRICAL PANEL

SCHEDULES

CO

OP

ER

HA

LL R

EN

OV

AT

ION

AT

CA

MP

BL

AN

DIN

G J

OIN

TT

RA

ININ

G C

EN

TE

R (

CB

JT

C)

CLA

Y C

OU

NT

YS

TA

RK

E,

FL

DE

SIG

N P

HA

SE

: B

ID D

OC

UM

EN

TS

AEV

01318

RE

VIS

ION

S

PER NEC ARTICLE 220 KITCHEN (K) 11.6 1.00 0.65 7.5

DRYERS (D) 0.0 1.00 1.00 0.0EQUIPMENT GROUND BUS

WATER HEATERS (W) 0.0 1.00 1.25 0.0 PANEL EQUIPMENT:

OTHER (O) 0.0 1.00 1.00 0.0

COOLING (C) 29.5 1.00 1.00 29.5 PERCENT... 7.4 %

HEATING (H) 0.0 1.00 1.00 0.0

ALL OTHER MOTORS (M) 11.2 1.00 1.00 11.2

LARGEST MOTOR (M) 2.8 1.00 1.25 3.5 DEMAND AMPS: 164.4 AMPS

RECEPTACLES (R) 6.0 --- NEC 6.0 TOTAL DEMAND LOAD: 59.2 KVA

LIGHTING (L) 1.2 1.00 1.25 1.4 TOTAL CONNECTED LOAD: 62.2 KVA

CONN. LOAD(KVA)

ADJUST.FACTOR

DEMANDFACTOR

DEMANDLOAD (KVA)

10.8 10.6 10.5 10.4 10.7 9.2

59 SPARE 20 1 1 20 SPARE 60

57 SPARE 20 1 1 20 SPARE 58

55 SPARE 20 1 1 20 SPARE 56

53 SPARE 20 1 1 20 SPARE 54

51 SPARE 20 1 1 20 SPARE 52

49 SPARE 20 1 1 20 SPARE 50

47 SPARE 20 1 0.1 48

45 SPARE 20 12 20

0.1C AC-9

46

43 SPARE 20 1 1 20 SPARE 44

41 2.4 1.9 42

39 2.42 20

1.9C VRCU-3

40

37

CU-3 C

2.4

35 3

0.1 38

35 2.02 20

0.1C AC-6

36

33 2.0 1.9 34

31

OACU-1 C

2.0

25 32 20

1.9C VRCU-1

32

SECTION: 2 (VERTICAL)

29 RECEPTACLES - ROOM 113 R 0.6 20 1 1 20 0.5 L LIGHTING - ROOMS 108, 109, 110, 111 30

27 RECEPTACLES - MIXER K 1.2 20 1 1 20 0.6 L LIGHTING - ROOMS 113, 114, 115 28

25 RECEPTACLES - REFRIGERATOR K 1.2 20 1 1 20 0.4 R RECEPTACLES - ROOM 113 26

23 1.6 1 20 0.4 R RECEPTACLES - ROOM 113 24

21RECEPTACLES - ICE MAKER K

1.620 2

1 20 1.8 K RECEPTACLES - MEAT... 22

19 RECEPTACLES - FREEZER K 1.2 20 1 1 20 1.8 K RECEPTACLES - ICE TEA MAKER 20

17 2.7 1 20 0.6 R RECEPTACLES - ROOM 113 18

15 2.7 1 20 0.6 R RECEPTACLES - ROOM 113 16

13

OAU-1 C

2.7

25 3

1 30 2.8 M HAND DRYER - ROOM 115 14

11 RECEPTACLES - EXTERIOR R 0.4 20 1 1 30 2.8 M HAND DRYER - ROOM 110 12

9 0.1 1 30 2.8 M HAND DRYER - ROOM 110 10

7AC-7 C

0.120 2

1 30 2.8 M HAND DRYER - ROOM 109 8

5 RECEPTACLES - ROOMS 108, 111, 114 R 0.8 20 1 1 30 2.8 M HAND DRYER - ROOM 109 6

3 RECEPTACLES - ROOM 108 R 0.6 20 1 1 20 1.0 R RECEPTACLES - ROOMS 109, 110, 113, 115 4

1 RECEPTACLES - REACH-IN COOLER K 1.2 20 1 1 20 0.6 R RECEPTACLES - ROOM 108 2

A B C TRIP POLES POLES TRIP A B C

NO

TE

S

CK

T #

CIRCUIT DESCRIPTION

CO

DE LOAD/PHASE (KVA) CIRCUIT BREAKER LOAD/PHASE (KVA)

CO

DE

CIRCUIT DESCRIPTION

CK

T #

NO

TE

S

SECTION: 1

WIRE: 4 MANUFACTURER: SIEMENS Fed From: MDP

PHASE: 3 MOUNTING: FLUSH Project Number: 2015-4111

VOLTAGE: 208Y/120V AIC: 42 K AMPS FULLY RATED Project Name: COOPER HALL

MAIN LUGS: 225 AMPS Status: NEW

Name: 1A

12.5 1.00 0.65 8.1 (K) KITCHEN PER NEC ARTICLE 220

0.0 1.00 1.00 0.0 (D) DRYERS

PANEL EQUIPMENT: 0.0 1.00 1.25 0.0 (W) WATER HEATERS

0.0 1.00 1.00 0.0 (O) OTHER

45.1 1.00 1.00 45.1 (C) COOLING

0.0 1.00 1.00 0.0 (H) HEATING

14.0 1.00 1.00 14.0 (M) ALL OTHER MOTORS

TOTAL DEMAND AMPS: 280.7 AMPS 2.8 1.00 1.25 3.5 (M) LARGEST MOTOR

TOTAL DEMAND LOAD: 101.0 KVA 15.2 ---- NEC 12.6 (R) RECEPTACLES

TOTAL CONN LOAD: 103.7 KVA 14.2 1.00 1.25 17.7 (L) LIGHTING

CONN. LOAD(KVA)

ADJUST.FACTOR

DEMANDFACTOR

DEMANDLOAD (KVA)

TOTAL 91.1 12.6 TOTAL

11 3 3 12

9 3 3 10

7 3 3 8

5 3 3 6

3 PANEL 1B 28.9 3 3 4

1 PANEL 1A 62.2 3 3 12.6 PANEL 2A 2

TRIP POLES POLES TRIP

NO

TE

S

CK

T #

CIRCUIT DESCRIPTION

CO

DE LOAD

(KVA)

CIRCUIT BREAKER

LOAD(KVA) C

OD

E

CIRCUIT DESCRIPTION

CK

T #

NO

TE

S

SECTION: 1

MANUFACTURER: SIEMENS

MOUNTING: FLOOR

AIC: 65 K AMPS FULLY RATED Fed From: EXISTING SERVICE

WIRE: 4 Project Number: 2015-4111

PHASE: 3 Project Name: COOPER HALL

VOLTAGE: 208Y/120V Status: EXISTING

MAIN BREAKER: 800 AMPS

Name: MDP

PER NEC ARTICLE 220 KITCHEN (K) 0.9 1.00 1.00 0.9

DRYERS (D) 0.0 1.00 1.00 0.0EQUIPMENT GROUND BUS

WATER HEATERS (W) 0.0 1.00 1.25 0.0 PANEL EQUIPMENT:

OTHER (O) 0.0 1.00 1.00 0.0

COOLING (C) 1.6 1.00 1.00 1.6 PERCENT... 0.0 %

HEATING (H) 0.0 1.00 1.00 0.0

ALL OTHER MOTORS (M) 0.0 1.00 1.00 0.0

LARGEST MOTOR (M) 2.8 1.00 1.25 3.5 DEMAND AMPS: 39.5 AMPS

RECEPTACLES (R) 3.6 --- NEC 3.6 TOTAL DEMAND LOAD: 14.2 KVA

LIGHTING (L) 3.7 1.00 1.25 4.6 TOTAL CONNECTED... 12.6 KVA

CONN.LOAD(KVA)

ADJUST.FACTOR

DEMANDFACTOR

DEMANDLOAD(KVA)

3.4 1.9 2.0 0.8 2.3 2.2

41 20 1 1 20 42

39 20 1 1 20 40

37 20 1 1 20 38

35 20 1 1 20 36

33 20 1 1 20 34

31 20 1 1 20 32

29 20 1 1 20 30

27 20 1 1 20 28

25 20 1 1 20 26

23 20 1 1 20 24

21 20 1 1 20 22

19 20 1 1 20 20

17 0.8 1 20 0.9 L LIGHTING - ROOM 18

15AHU-3 C

0.820 2

1 20 0.8 L LIGHTING - ROOM 16

13 20 1 1 20 14

11 RECEPTACLES - UC REFRIGERATOR K 0.6 20 1 1 20 0.4 L LIGHTING - ROOM 12

9 RECEPTACLES - UC ICE MAKER K 0.3 20 1 1 20 0.7 L LIGHTING - ROOM 10

7 HAND DRYER - ROOM 204 M 2.8 30 1 1 20 8

5 RECEPTACLES - ROOM 203 R 0.6 20 1 1 20 0.9 L LIGHTING - ROOM 6

3 RECEPTACLES - ROOMS 203, 204, 207 R 0.8 20 1 1 20 0.8 R RECEPTACLES - ROOMS 201, 202, 203 4

1 RECEPTACLES - ROOM 203 R 0.6 20 1 1 20 0.8 R RECEPTACLES - ROOMS 203, 205, 206 2

A B C TRIP POLES POLES TRIP A B C

NO

TE

S

CK

T #

CIRCUIT DESCRIPTION

CO

DE LOAD/PHASE (KVA) CIRCUIT BREAKER LOAD/PHASE (KVA)

CO

DE

CIRCUIT DESCRIPTION

CK

T #

NO

TE

S

SECTION: 1

WIRE: 4 MANUFACTURER: SIEMENS Fed From: MDP

PHASE: 3 MOUNTING: FLUSH Project Number: 2015-4111

VOLTAGE: 208Y/120V AIC: 42 K AMPS FULLY RATED Project Name: COOPER HALL

MAIN LUGS: 225 AMPS Status: NEW

Name: 2A

PER NEC ARTICLE 220 KITCHEN (K) 0.0 1.00 1.00 0.0

DRYERS (D) 0.0 1.00 1.00 0.0EQUIPMENT GROUND BUS

WATER HEATERS (W) 0.0 1.00 1.25 0.0 PANEL EQUIPMENT:

OTHER (O) 0.0 1.00 1.00 0.0

COOLING (C) 14.0 1.00 1.00 14.0 PERCENT... 4.1 %

HEATING (H) 0.0 1.00 1.00 0.0

ALL OTHER MOTORS (M) 0.0 1.00 1.00 0.0

LARGEST MOTOR (M) 0.0 1.00 1.25 0.0 DEMAND AMPS: 86.8 AMPS

RECEPTACLES (R) 5.6 --- NEC 5.6 TOTAL DEMAND LOAD: 31.2 KVA

LIGHTING (L) 9.3 1.00 1.25 11.6 TOTAL CONNECTED... 28.9 KVA

CONN.LOAD (KVA)

ADJUST.FACTOR

DEMANDFACTOR

DEMANDLOAD (KVA)

3.8 3.9 5.0 5.9 5.9 4.4

41 SPARE 20 1 1 20 SPARE 42

39 SPARE 20 1 1 20 SPARE 40

37 SPARE 20 1 1 20 SPARE 38

35 SPARE 20 1 1 20 1.0 L LIGHTING - ROOM 105 36

33 SPARE 20 1 1 20 1.0 L LIGHTING - ROOM 105 34

31 SPARE 20 1 1.0 32

29 LIGHTING - RMS. 101, 102, 103, 105, 106, 112, 116 L 1.2 20 12 20

1.0L LIGHTING - ROOM 105

30

27 LIGHTING - ROOM 107 L 1.2 20 1 1 20 1.0 L LIGHTING - ROOM 105 28

25 LIGHTING - ROOM 107 L 0.9 20 1 1 20 1.0 L LIGHTING - ROOM 105 26

23 SPARE 20 1 1 20 SPARE 24

21 RECEPTACLES - ROOMS 105, 107 R 1.0 20 1 2.2 22

19 SPARE 20 1 2.2 20

17 RECEPTACLES - ROOMS 105, 107 R 1.0 20 1

3 40

2.2

C CU-1

18

15 RECEPTACLES - ROOMS 103, 107 R 1.2 20 1 0.6 16

13 2.72 20

0.6C AHU-1

14

11VRCU-2 C

2.720 2

0.1 12

9 RECEPTACLES - EXTERIOR R 0.4 30 12 20

0.1C AC-8

10

7 0.1 0.1 8

5AC-2 C

0.120 2 2 20

0.1C AC-5

6

3 0.1 1 20 1.0 R RECEPTACLES - ROOMS 105, 106 4

1AC-1 C

0.120 2

1 20 1.0 R RECEPTACLES - ROOMS 102, 103, 112, 116 2

A B C TRIP POLES POLES TRIP A B C

NO

TE

S

CK

T #

CIRCUIT DESCRIPTION

CO

DE LOAD/PHASE (KVA) CIRCUIT BREAKER LOAD/PHASE (KVA)

CO

DE

CIRCUIT DESCRIPTION

CK

T #

NO

TE

S

SECTION: 1

WIRE: 4 MANUFACTURER: SIEMENS Fed From: MDP

PHASE: 3 MOUNTING: FLUSH Project Number: 2015-4111

VOLTAGE: 208Y/120V AIC: 42 K AMPS FULLY RATED Project Name: COOPER HALL

MAIN LUGS: 225 AMPS Status: NEW

Name: 1B